For applications with pressure fluctuations install Tighten the lock screws.
a dampener to eliminate chattering of microswitch
and excessive pressure cycling of bellows. For In instruments with two SPDT switches for DPDT
steam, use a condensor coil or a syphon. action, the synchronisation of actuation is done
within practical limits. The switches are
If process temperature is higher than 70°C at synchronised as per customer preference, either
the instrument end, it can be brought down by on “falling” or on “rising” pressure. If no
using longer pressure piping. Ask factory for preference is indicated, synchronisation is done
piping nomogram. for FALL in pressure at factory.
MOUNTING DIMENSIONS
20.0 115.0
104.0 9.5 36.0
LOCKING
DEVICE
24.0
81.0 90.0
3/4" ET PVC
CABLE GLAND
A±2 SENSING
ELEMENT
(BELLOWS)
MOUNTING LUGS
35.0
23.0
PROCESS
CONNECTION
All dimensions are in mm.