Sei sulla pagina 1di 55

Internal Use Only▲

FDD LTE Radio Parameters


Description Guide

CDMA & FDD LTE Product Support Department


Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

Basic Cell Parameters


 Physical Cell ID

 Parameter Description
 This parameter identifies a unique physical cell that can be included in only one cell
group. A system provides a total number of 504 physical cell IDs, which are classified
into 168 groups, each group containing three unique IDs.
 When configuring this parameter, ensure that physical cell IDs should be space
multiplexing as planned.

 Value Range and Step Length


 Value Range: Int (0, 1, … , 503)
 Default Value: 0

 Configuration Principles
 A physical cell ID should be uniquely assigned for the same frequency point in the same
geographical area or in different PLMNs (especially at the cell edge).
 To separate the primary synchronous channels among adjacent cells, ZTE recommends
you set them to 0, 1, and 2 because a macro eNodeB consists of three cells.
Internal Use Only▲

Basic Cell Parameters


 CP Selection for Physical Channel

 Parameter Description
This parameter indicates the cyclic prefix (CP) of the OFDM symbol, which is used to
determine the total number of OFDM symbols within one slot. When this parameter is set to
normal cyclic prefix, it implies that seven OFDM symbols are available within one slot.
When this parameter is set to extended cyclic prefix, it implies that six OFDM symbols are
available within one slot.
he
 Value Range and Step Length
 Value Range: Enum (normal cyclic prefix, extended cyclic prefix)
 Default Value: normal cyclic prefix

 Configuration Principles
 The CP is dependent on the multipath delay of a radio channel. In the presence of either
a large multipath delay or a large cell radius, extended cyclic prefix is recommended.
 The extended cyclic prefix option can suppress radio interference caused by multipath
delay, but suffering from lower system capacity; and therefore it is recommended that
you set it to the default value.
Internal Use Only▲

Basic Cell Parameters


 Downlink System Bandwidth

 Parameter Description
This parameter indicates the system bandwidth in the downlink, which is used to
determine the frequency domain location of the downlink physical channel as well as
downlink frequency allocation.

 Value Range and Step Length


 Value Range: Enum (6, 15, 25, 50, 75, 100) Unit: RB
 Default Value: 100

 Configuration Principles
 This parameter is dependent on the frequency bandwidth acquired by a mobile
operator. The downlink system bandwidth can either be identical to or different from
the uplink system bandwidth.
 Modifying this parameter can have an impact on downlink resource allocation.
Internal Use Only▲

Basic Cell Parameters


 Uplink System Bandwidth

 Parameter Description
This parameter indicates the system bandwidth in the uplink, which is used to determine
the frequency domain location of the uplink physical channel as well as uplink frequency
allocation.

 Value Range and Step Length


 Value Range: Enum (6, 15, 25, 50, 75, 100) Unit: RB
 Default Value: 100

 Configuration Principles
 This parameter is dependent on the frequency bandwidth acquired by a mobile
operator. The downlink system bandwidth can either be identical to or different from
the uplink system bandwidth.
 Modifying this parameter can have an impact on uplink resource allocation.
Internal Use Only▲

Basic Cell Parameters


 Cell Max Transmit Power

 Parameter Description
This parameter specifies the maximum available transmit power.

 Value Range and Step Length


 Value Range: Float (0, …, 50) Step: 0.1 Unit: dBm
 Default Value: 43

 Configuration Principles
The default value is intended to be used in the following environment:
Object Value Object Value
Site Spacing 800 m Frequency Spectrum 2.6 G
BS Height 25 m Antenna Gain 18 dBi
Maximum Transmit Power (UE) 24 dBm Body/Path Loss 3 dB
Maximum Uplink Throughput at Cell 128 kbps Shadow Fade Margin 10 dB
Edge (UE Dynamic Scheduling)
Maximum Downlink Throughput 800 kbps Penetration Loss 20 dB
Maximum Throughput (UE Semi- 32 kbps
Dynamic Scheduling)
Internal Use Only▲

Basic Cell Parameters


 Cell Transmit Power

 Parameter Description
This parameter specifies the used transmit power.

 Value Range and Step Length


 Value Range: Float (0, …, 50) Step: 0.1 Unit: dBm
 Default Value: 43

 Configuration Principles
 For the environment information about the use of the default value, see page 7
(Cell Max Transmit Power).
 This parameter is dependent on the cell radius and the planned downlink
throughput at the cell edge. The greater the cell radius or the planned downlink
throughput at the cell edge, the greater the value of this parameter is required.
Internal Use Only▲

Basic Cell Parameters


 Cell-specific Reference Signals Power

 Parameter Description
This parameter specifies the absolute power value of the cell reference signal for each
resource element.

 Value Range and Step Length


 Value Range: Int (-60, …, 50) Unit: dBm
 Default Value: 6

 Configuration Principles
 For the environment information about the use of the default value, see page 7 (Cell Max
Transmit Power).
 This parameter is dependent on cell coverage. The greater the cell coverage, the greater
the value of this parameter is required. This parameter should be used for ensuring cell
coverage while achieving the maximum power.
 A reference signal power value should be properly tuned in accordance with the required
power of the downlink control channel at the cell edge based on the link estimation
calculated by using such radio parameters as cell type, cell radius, and antenna height.
Internal Use Only▲

Basic Cell Parameters


 Switch for User Inactivity

 Parameter Description
This parameter specifies whether to enable the USER INACTIVITY feature.

 Parameter Location in the OMC


To find this parameter, choose Views > Configuration Management > LTENE > Global
Parameters of eNodeB in the OMC.

 Value Range and Step Length


 Value Range: Enum (close, open)
 Default Value: close
Internal Use Only▲

Basic Cell Parameters


 User Inactivity Timer

 Parameter Description
This parameter specifies the time interval at which the UE is in inactive state.

 Parameter Location in the OMC


To find this parameter, choose Views > Configuration Management > LTENE > Global
Parameters of eNodeB in the OMC.

 Value Range and Step Length


 Value Range: one second to 30 days

 Default Value: 10 minutes


Internal Use Only▲

Basic Cell Parameters


 Pmax

 Parameter Description
This parameter specifies the maximum transmit power allowed for the UE configured on
the higher layer.

 Value Range and Step Length


 Value Range: Int (-30, …, 33) Unit: dBm
 Default Value: 23

 Configuration Principles
 For the environment information about the use of the default value, see page 7
(Cell Max Transmit Power).
 This parameter is dependent on the cell radius and the planned uplink throughput
at the cell edge. The greater the cell radius or the planned uplink throughput at the
cell edge, the greater the value of this parameter is required.
Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

小区选择和重选参数
 Sel_Qrxlevmin

 Parameter Description
 This parameter indicates the minimum required received power level of the cell
which satisfies the condition of being selected by UE. Only the measured received
power level of the cell is over Sel_Qrxlevmin can the cell be selected. Range of the
parameter is actual value which equals to double of value in 36.331.

 Value Range and Step Length


 int (-140, .., .-44) step 2 unit dBm
 Default value: -110

 Configuration Principles
 For normal cases, the default value is recommended. In some urban area with a
few sites, the value of this parameter could be less than default value.
Internal Use Only▲

小区选择和重选参数
 Q_RxLevMinOffset

 Parameter Description
 This parameter indicates the offset of the minimum required received power level of
the cell which satisfies the condition of being selected or reselected by UE. It will
affect the minimum required received power level in the cell. Range of the
parameter is actual value which equals to double of value in 36.331.

 Value Range and Step Length


 int (2, .., .16) step 2 unit dB
 Default value: 2

 Configuration Principles
 Offset to the signalled Qrxlevmin taken into account in the Srxlev evaluation as a
result of a periodic search for a higher priority PLMN while camped normally in a
VPLMN.For normal cases, the default value is recommended. For some higher
priority PLMN scenario, the value could be greater than the default value.
(Depending on the coverage, loading, requirements of the high priority PLMN.
Internal Use Only▲

小区选择和重选参数
 Qhyst

 Parameter Description
 This parameter indicates the hysteresis value for cells. In cell-ranking criterion R of
cell reselection, the R value of serving cell equals to the measured value plus the
hysteresis value. For detail description please refer to TS 36.304.

 Value Range and Step Length


 int (0, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24)
 Default value: 3

 Configuration Principles
 This specifies the hysteresis value for ranking criteria of serving cell. If a cell is
ranked as the best cell the UE shall perform cell reselection to that cell.The default
value is recommende to be used in normal cases.The greater is the value of this
parameter, the harder to fullfill the reselection process.
Internal Use Only▲

Cell Selection and Reselection Parameters


 ThresholdServing_Low

 Parameter Description
This parameter specifies the low threshold for the serving carrier when the low priority carrier or
system is selected and the following conditions can be fulfilled:
 The cell without any high priority carrier or system can meet the cell reselection criteria for
escalating to a higher priority.
 When the Treselection threshold is not exceeded, SServingCell is smaller than
byThreshSvrLow while SnonServingCell,x (low priority carrier or system) is greater than
byThreshSvrLow (including inter-frequency and inter-system).
 The UE has resided in the serving cell for more than one second.

 Value Range and Step Length


 Value Range: Int (0, …, 62) Step: 2 Unit: dB
 Default Value: 0

 Configuration Principles
 This threshold is used when the UE evaluates and reselects a low-priority E-UTRAN or RAT
frequency point as the serving frequency point.
 TheSServingCell threshold is applicable to the serving cell. When this SServingCell threshold
is reached, it is likely that the cell reselection will be triggered.
Internal Use Only▲

Cell Selection and Reselection Parameters


 S_Intrasearch

 Parameter Description
This parameter specifies the intra-frequency measurement trigger threshold for cell selection. The UE
is used to determine whether to implement the intra-frequency measurement.

 Value Range and Step Length


 Value Range: Int (0, ..., 62) Step: 2 Unit: dB
 Default Value: 14

 Configuration Principles
 When the quality of the serving cell is greater than the S_intrasearch value, the UE does not
implement the intra-frequency measurement.
 When the quality of the serving cell is equal to or smaller than the S_intrasearch value, the UE
implements the intra-frequency measurement.
 Setting this parameter to a too small value will cause the UE to fail in implementing the intra-
frequency measurement in a timely manner, and thus failing to reselect an adjacent intra-
frequency cell.
 Setting this parameter to a too large value will cause the UE to waste battery resources.
Internal Use Only▲

Cell Selection and Reselection Parameters


 IntraQ_OffsetCell

 Parameter Description
This parameter specifies the intra-frequency cell reselection offset that is used to tune
adjacent cells using the R criteria, and therefore it is comparable to the Qhyst parameter.

 Value Range and Step Length


 Value Range: Enum (-24,-22,-20, -18, -16, -14, -12, -10, -8, -6, -5, -4, -3, -2, -1, 0, 1,
2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24) Unit: dB
 Default Value: 0

 Configuration Principles
Do not set this parameter to a too large value. Otherwise, the serving cell is very poor,
but cannot be reselected.
Internal Use Only▲

Cell Selection and Reselection Parameters


 Intra_Pmax

 Parameter Description
This parameter specifies the maximum available uplink transmit power, depending on
the UE type. It is used for intra-frequency cell reselection. If this parameter is void, the
UE will follow its own capabilities for further handling.

 Value Range and Step Length


 Value Range: Int (-30..33) Unit: dBm
 Default Value: 23

 Configuration Principles
 For more information, see page 12 (Pmax). The Intra_Pmax parameter is
dependent on the configuration data of adjacent cells.
 Modifying this parameter can have an impact on SIB3.
Internal Use Only▲

Cell Selection and Reselection Parameters


 The Timer for Cell Reselection in Inter-frequency E-UTRAN

 Parameter Description
This parameter represents an inter-frequency cell reselection timer. Within the
TreselectionInterEUTRAN, a new E-UTRAN inter-frequency cell, which performs better
than the serving cell using the R criteria, can be reselected as a new serving cell.

 Value Range and Step Length


 Value Range: Int (0, …, 7) Unit: s
 Default Value: 1

 Configuration Principles
 This parameter is comparable to the tRslIntraEutra parameter, which represents
an intra-frequency cell reselection timer. You can set it to a value that is equal to or
slightly greater than the tRslIntraEutra parameter.
 Modifying this parameter can have an impact on SIB5.
Internal Use Only▲

Cell Selection and Reselection Parameters


 Intra-frequency Cell Reselection Priority

 Parameter Description
This parameter specifies the priority for intra-frequency cell reselection. The smaller the value
of this parameter, the lower the cell reselection priority is.

 Value Range and Step Length


 Value Range: Int (0, …, 7) Step: 1
 Default Value: 0

 Configuration Principles
 The UE can implement the cell reselection process for only E-UTRAN frequency points
and inter-system frequency points that have acquired the priority based on the
corresponding system information. However, the UE will never consider any blacklisted
cell as a candidate for cell reselection.
 If an adjacent cell has higher priority than the serving cell during the cell reselection
measurement, the UE will unconditionally enable the intra-system or inter-system
measurement. A higher priority cell takes precedence during the cell reselection process.
 Modifying this parameter can have an impact on SIB3.
Internal Use Only▲

Cell Selection and Reselection Parameters


 Intra-frequency Neighbour CSG Cell Physical Identity Range

 Parameter Description
This parameter specifies the total number of CSG cells in an intra-frequency neighboring
CSG cell group.

 Value Range and Step Length


 Value Range: Enum (4, 8, 12, 16, 24, 32, 48, 64, 84, 96, 128, 168, 252, 504)
 Default Value: 4

 Configuration Principles
 If this parameter is void, it implies that only one CSG neighboring cell is present.
The physical identify of this CSG cell is represented by the
intraFreqCSGPhyCellId_lowest parameter.
 Modifying this parameter can have an impact on SIB4.
Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

Random Access Parameters


Key random access parameters include:
 Cell High-Speed Attribute
 Ncs Used to Generate PRACH Preamble
 Logical Root Sequence Start Number Used to Generate PRACH Preamble
 Number of Non-dedicated Random Access Preambles
 Size of Random Access Preambles Group A
 Threshold of Selecting Preamble Group
 Message Power Offset for Group B
 the Initial RB Number for Random Access Preambles
 PRACH Configuration Index PRACH
 Initial Power for Preamble of PRACH
 Power Ramping Step for PRACH
 Max retransmit number for PRACH
 TTI Window Size for PRACH Response
 Max Number of Messages HARQ Transmissions Message 3
 MAC Contention Resolution Timer
 Dedicated Preamble Life Time
Internal Use Only▲

Random Access Parameters


Cell High-Speed Attribute
Default Value: Not high speed cell
Value Range: Enum {Not high speed cell, high speed cell}

Preamble RadiusThrdLR RadiusThrdH


Format a (km) Ra (km)
0 0 14
1 29 77
Cell Radius 2 14 29
3 77 100
Internal Use Only▲

Random Access Parameters


TCP TSEQ TGP

CP Sequence Guard Pd
T RTD TMTD

Preamble TCP TMTD MaxCellRadius


format TMTDTGP (km)

Rcell  min( TCP  TMTD , TGP ) / 6.67 0 103.2768 97.0176 5.2 14.545367

1 685.3824 516.384 16.7 77.418191

2 203.424 197.1648 16.7 27.994603

3 685.3824 716.6784 16.7 100.25223

One subframe (1ms)

15360  Ts 15360  Ts 15360  Ts 15360  Ts 15360  Ts 15360  Ts


One slot Cell Radius (Supported):
2976  Ts
3168  Ts 24576 T
24576  Tss Format 0 – 15 km
0
30 – 77 km
21024  Ts 24576  Ts Format
15840  Ts 15 – 30 km
1
6240  Ts 24576  Ts 24576  Ts 6080  Ts
Format 77 – 100 km
2
Format
21024  Ts 24576  Ts 24576  Ts 21993  Ts
3
Internal Use Only▲

Random Access Parameters


Ncs Used to Generate PRACH Preamble
Value Range: [1, …, 11] Default Value: 10

N CS for Preamble Generation (Preamble Formats 0-3)

Low and
Ncs Cell High Cell
Medium Preamble Number of Preamble Number of
configurati Radius Speed Ncs Radius
Speed Ncs Ncs Roots (u) Ncs Roots (u)
on (km) (≥) (km)
(<)

0 0 118.93 1 64 15 1.08 55 2
1 13 0.79 64 1 18 1.51 46 2
2 15 1.08 55 2 22 2.08 38 2
3 18 1.51 46 2 26 2.65 32 2
4 22 2.08 38 2 32 3.51 26 3
5 26 2.65 32 2 38 4.37 22 3
6 32 3.51 26 3 46 5.51 18 4
7 38 4.37 22 3 55 6.80 15 5
8 46 5.51 18 4 68 8.66 12 6
9 59 7.37 14 5 82 10.66 10 7
10 76 9.80 11 6 100 13.23 8 8
11 93 12.23 9 8 128 17.23 6 11
12 119 15.95 7 10 158 21.52 5 13
13 167 22.82 5 13 202 27.81 4 16
14 279 38.84 3 22 237 32.82 3 22
15 419 58.86 2 32 - -
Internal Use Only▲

Random Access Parameters


Logical Root Sequence Start Number Used to Generate PRACH
Value Range: [0, ..., 837] Default Value: N/A
Root Zadoff-Chu Sequence Order for Preamble Format 0 – 3
Logical root Physical root sequence number u
sequence number (in increasing order of the corresponding logical sequence number)
0–23 129, 710, 140, 699, 120, 719, 210, 629, 168, 671, 84, 755, 105, 734, 93, 746, 70, 769, 60, 779
2, 837, 1, 838

24–29 56, 783, 112, 727, 148, 691

… …

204-263 152, 687, 144, 695, 134, 705, 138, 701, 199, 640, 162, 677, 176, 663, 119
720, 158, 681, 164, 675, 174, 665, 171, 668, 170, 669, 87, 752, 169, 670, 88, 751, 107, 732, 81, 758, 82, 757, 100, 739, 98, 741,
71, 768, 59, 780, 65, 774, 50, 789, 49, 790, 26, 813, 17, 822, 13, 826, 6, 833

… …

328–383 225, 614, 224, 615, 221, 618, 220, 619, 127, 712, 147, 692, 124, 715, 193, 646, 205, 634, 206, 633, 116, 723, 160, 679, 186,
653, 167, 672, 79, 760, 85, 754, 77, 762, 92, 747, 58, 781, 62, 777, 69, 770, 54, 785, 36, 803, 32, 807, 25, 814, 18, 821, 11, 828,
4, 835

384–455 3, 836, 19, 820, 22, 817, 41, 798, 38, 801, 44, 795, 52, 787, 45, 794, 63, 776, 67, 772, 72, 767, 76, 763, 94, 745, 102, 737, 90,
749, 109, 730, 165, 674, 111, 728, 209, 630, 204, 635, 117, 722, 188, 651, 159, 680, 198, 641, 113, 726, 183, 656, 180, 659,
177, 662, 196, 643, 155, 684, 214, 625, 126, 713, 131, 708, 219, 620, 222, 617, 226, 613

… …

820-837 336, 503, 305, 534, 373, 466, 280, 559, 279, 560, 419, 420, 240, 599, 258, 581, 229, 610
Internal Use Only▲

Random Access Parameters


Number of Non-dedicated
Random Access Preambles
Default Value: 60
Value Range: Enum {
64 Preambles 4, 8, 12, 16, 20, 24, 28, 32, 36,
40, 44, 48, 52, 56, 60, 64}

n Preamble Dedicated m Preamble Non-dedicated

p Preamble Group A q Preamble Group B

Size of Random Access Threshold of Selecting Message Power Offset for


Preambles Group A Preamble Group Group B
Default Value: 56 Default Value: 144 bit Default Value: 0 dB
Value Range: Enum { Value Range: Enum { Value Range: Enum {
4, 8, 12, 16, 20, 24, 28, 32, 36, 56, 144, 208, 256} bit -infinity, 0, 5, 8, 10, 12, 15,
40, 44, 48, 52, 56, 60} 18} dB
Internal Use Only▲

Random Access Parameters


Initial RB Number for PRACH Configuration Index
Random Access Preambles Value Range: [0, …, 63]
Value Range: [0, …, 94] Default Value: 3
Default Value: Void

Specifical Uplink
subframe subframe

nPRB  49
nPRB  48
nPRB  47
……………

nPRB  8
nPRB  7
………...

nPRB=2
nPRB  2
nPRB  1
nPRB  0

0n N 6
SR CCR#0 data: CQI CCR#0 pilot: CQI
RA UL
PRBoffset RB PUSCH CCR#1 data: CQI CCR#1 pilot: CQI

DMRS CCR#2 data: ACK/NACK CCR#2 pilot: ACK/NACK

RACH CCR#3 data: ACK/NACK CCR#3 pilot: ACK/NACK


Internal Use Only▲

Random Access Parameters


Frame Structure Type 1 Random Access Configuration for Preamble Format 0
PRACH Configuration Index Preamble Format System frame number Sub-frame number
0 0 Even 1

1 0 Even 4

2 0 Even 7

3 0 Any 1

4 0 Any 4

5 0 Any 7

6 0 Any 1, 6

7 0 Any 2 ,7

8 0 Any 3, 8

9 0 Any 1, 4, 7

10 0 Any 2, 5, 8

11 0 Any 3, 6, 9

12 0 Any 0, 2, 4, 6, 8
Number of Prach Configuration Index
13 slots per 0 Any 1, 3, 5, 7, 9
second Preamble Format 0 Preamble Format 1 Preamble Format 2 Preamble Format 3
14 0 Any 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
50 0, 1, 2, 15 16, 17, 18, 31 32, 33, 34, 47 48, 49, 50, 63
15 0 Even 9
100 3, 4, 5 19, 20, 21 35, 36, 37 51, 52, 53
 The number of random 200 6, 7, 8 22, 23, 24 38, 39, 40 54, 55, 56
accessing based on
contention resolution 300 9, 10, 11 25, 26, 27 41, 42, 43 57, 58, 59
 Probability of RA
colliding 500 12, 13 28, 29 44, 45 N/A
 Physical Cell ID
1000 14 N/A N/A N/A
Internal Use Only▲

Random Access Parameters


Max retransmit number for PRACH
Default Value: 8 P0 +5deta(P)

Value Range: Enum {3, 4, 5, 6, 7, 8, 10, 20, Ramping Power (Configurable)


50, 100, 200}
P0 +3deta(P)
Power Ramping Step for PRACH
P0 +2deta(P)
Default Value: 2 dB
P0 +deta(P)
Value Range: Enum {0, 2, 4, 6} dB
P0
Initial Power for Preamble of PRACH
Default Value: -110 dBm
Value Range: Enum {
-120,-118,-116,-114,-112,-110,-108,- T1 T2 T3 T4 T5 T6

106,-104,-102,-100,-98,-96,-94,-
92,-90} dBm

PRACH = min{PcMAX, PREAMBLE_RECEIVED_TARGET_POWER + PL}


PcMAX = Plmax + Pinitial + (N-1) * Step
Internal Use Only▲

Random Access Parameters


TTI Window Size for PRACH
UE eNodeB
Response
Default Value: 10ms
Msg1: Random Access Preamble
Value Range: Enum {
2, 3, 4, 5, 6, 7, 8, 10} ms

Max Number of Messages Msg2: Random Access Response


HARQ Transmissions
Default Value: 3
Value Range: [1, …, 8]

Msg3: Scheduled Transmission


MAC Contention Resolution
Timer
Default Value: 48sf
Value Range: Enum {
Msg4: Contention Resolution
8, 16, 24, 32, 40, 48, 56, 64} sf
Internal Use Only▲
Dedicated Preamble Life Time
Random Access Parameters Default Value: 100 ms
Value Range: [0, …, 100] ms

UE eNodeB

Msg0: PDCCH Order


0
Dedicated Preamble ID, Mask Index

Msg1: Random Access Preamble


1
Dedicated Preamble

Msg2: RA Response
2
Sent on PDSCH

Msg3: Contention Requirement


3
Data or Padding
Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

Paging Parameters
 DRX Cycle for Paging

 Parameter Description
This parameter specifies the DRX cycle for paging purposes.

 Value Range and Step Length


 Value Range: Enum (32, 64, 128, 256) Unit: Sub-frame
 Default Value: 128

 Configuration Principles
 When the UE is in idle state but the DRX is being used, the UE needs to monitor a
P-RNTI in a paging occasion every DRX cycle.
 Modifying this parameter can have an impact on other UEs being in idle state.
Internal Use Only▲

Paging Parameters
 nB used to derive the Paging Frame and Paging Occasion

 Parameter Description
This parameter specifies the nB that is used to derive the paging frame and paging
occasion, as defined in TS36.304.

 Value Range and Step Length


 Value Range: Enum (4T, 2T, T, 1/2T, 1/4T, 1/8T, 1/16T, 1/32T)
 Default Value: T

 Configuration Principles
 This parameter is an integer multiplied by T.
 T represents a paging cycle. For example, 2T indicates two paging cycles and 4T
indicates four paging cycles.
Internal Use Only▲

Paging Parameters
 The Parameter to Determine BCCH Modification Period

 Parameter Description
This parameter is used to determine the BCCH modification period (BCCH modification
period = N * DRX cycle length for paging). The purpose of this constraint is to ensure
that all the UEs being in idle state can monitor the system broadcast change message.

 Value Range and Step Length


 Value Range: Enum (2, 4, 8, 16)
 Default Value: 4

 Configuration Principles
 The greater this parameter, the longer the system message is updated. This can
have an adverse impact on real-time message update.
 The smaller this parameter, the shorter the system message is updated. This can
cause the UE to monitor the systemInfoValueTag more frequently.
Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Trigger Quantity

 Parameter Description
This parameter specifies the measured value that is used for triggering an event.

 Value Range and Step Length


 Value Range: Enum (0, 1) 0=RSRP, 1=RSRQ
 Default Value: 0

 Configuration Principles
 RSRP is short for reference signal received power.
 RSRQ is short for reference signal received quality.
 When the UE detects that this parameter meets the threshold, it will trigger an intra-
frequency cell measurement event.
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Report Criteria

 Parameter Description
This parameter specifies whether the UE measurement report is event-triggered or
periodically triggered.

 Value Range and Step Length


 Value Range: Enum (0, 1) 0=Event Triggered Reporting, 1=Periodically Triggered
Reporting
 Default Value: 0

 Configuration Principles
For intra-frequency handoff measurement, this parameter must be set to 0 (event
triggered reporting).
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Threshold for RSRP

 Parameter Description
This parameter specifies the absolute RSRP threshold for the serving cell to decide
whether to trigger an event (A1, A2, A3, A4, and A5).

 Value Range and Step Length


 Value Range: A1/A2/A4/A5 : Int (-140, …, -44) Unit: dBm
 Value Range: A3: Float (-15, …, 15) Step 0.5 Unit: dB
 Default Value: [-75 -100 3 -90 -110]

 Configuration Principles
This parameter is valid only when the RptCriteria parameter is set to 0 (Event triggered
reporting). It is applicable to A1, A2, A3, A4, and A5 only. The A1 threshold is greater
than the A2 threshold.
Internal Use Only▲

Measurement Parameters
 Intra-Frequency A5 Threshold2 for RSRP

 Parameter Description
This parameter specifies the second RSRP threshold for an adjacent cell to decide
whether to trigger the A5 event .

 Value Range and Step Length


 Value Range: Int (-140, …, -44) Unit: dBm
 Default Value: -90

 Configuration Principles
 This parameter is mapped to the values that are defined in the 3GPP TS36.331: -
140 (0), -139 (1), …, -44 (96). It should be noted that no value is mapped to 97.
 Based on the A5 definition, this parameter must be greater than the Intra-
Frequency Threshold for RSRP parameter.
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Hysteresis

 Parameter Description
This parameter specifies the hysteresis that is used to decide whether to trigger an event.

 Value Range and Step Length


 Value Range: Float (0, …, 15) Step 0.5 Unit: dB
 Default Value:
 RSRP event-triggered reporting: [0 0 0 0 0]
 RSRP periodically triggered reporting: -
 RSRQ event-triggered reporting: [0 0 0 0 0]
 RSRQ periodically triggered reporting: -9
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Time to Trigger

 Parameter Description
This parameter specifies the time difference between event occurrence and event reporting.

 Value Range and Step Length


 Value Range: Enum (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280,
2560, 5120) Unit: ms
 Default Value: [256 256 256 256 256]

 Configuration Principles
 The greater this parameter is configured, the more stringent the event trigger
requirements becomes. You need to configure this parameter based on the desirable
requirements. Setting this parameter to a too large value will have an adverse impact on
call quality.
 The UE will trigger an event reporting only when the actual time reaches the threshold of
this parameter. This parameter is introduced to prevent the UE from any fraudulent
reporting caused by jitter. When configuring this parameter, you need to take the DRX
cycle into consideration.
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Reporting Interval for Event

 Parameter Description
This parameter specifies the time interval at which measurement results are periodically
reported after an event is triggered.

 Value Range and Step Length


 Value Range: Enum (120, 240, 480, 640, 1024, 2048, 5120, 10240, 60000, 360000,
720000, 1800000, 3600000) Unit: ms
 Default Value: [1024 1024 1024 1024 1024]

 Configuration Principles
 When an event is triggered, the UE reports measurement results at time intervals. If
the actual value reaches the threshold of this parameter, the UE will stop reporting
any measurement result.
 This parameter is valid only when the RptCriteria parameter is set to 0 (event
triggered reporting).
 This parameter must be greater than the TrigTime parameter.
Internal Use Only▲

Measurement Parameters
 Intra-Frequency Amount of Reporting for event

 Parameter Description
This parameter specifies the maximum number of reporting measurement results after
an event is triggered.

 Value Range and Step Length


 Value Range: Enum (1, 2, 4, 8, 16, 32, 64, Infinity)
 Default Value: [Infinity Infinity Infinity Infinity Infinity]

 Configuration Principles
 When an event is triggered, the UE reports measurement results at time intervals. If
the actual number reaches the threshold of this parameter, the UE will stop
reporting any measurement result.
 Do not set this parameter to a too large value because it is used for intra-frequency
handoff.
 This parameter is valid only when the RptCriteria parameter is set to 0 (event
triggered reporting).
Internal Use Only▲

Contents

Basic Cell Parameters

Cell Selection and Reselection Parameters

Random Access Parameters

Paging Parameters

Measurement Parameters

Handoff Parameters
Internal Use Only▲

Handoff Parameters
Coverage-based Inter-Site Handoff Measurement for Signal Strength

Average Field Strength Value of Average Field Strength Value of


Base Station A Base Station B

Base Station A Receiving Field Strength from Receiving Field Strength from
Base Station A Base Station B Base Station B
(Time and Position Dependent) (Time and Position Dependent)
Field Strength

Handover
Zone

Hysteresis

Distance

UE
Internal Use Only▲

Handoff Parameters
 Threshold
A threshold is used to evaluate signal quality (A5: absolute threshold, A3: relative threshold).

 Hysteresis and Timer


 Hysteresis and timer are used to determine whether to start or stop an event.

 Hysteresis is used to retard the start or stop of an event based on a decisive inequation,
which can greatly improve reliability for decision making. Hysteresis is normally used in
conjunction with a threshold.
 A timer is used to evaluate time-based constancy of a certain state (including the start or
stop of an event) for the purpose of improving accuracy and reliability for event reporting.
For this reason, a timer is irrelevant to a threshold.

 Customized Handoff Compensation


 It can be used to compensate either a serving or adjacent cell.

 When being added to the measured value of a serving cell, a positive compensation
value is used to prohibit a handoff.
 When being added to the measured value of an adjacent cell, a positive compensation
value is used to trigger a handoff.
Internal Use Only▲

Handoff Parameters
 Time to Trigger

 Parameter Description
This parameter specifies the time difference between event occurrence and event reporting.

 Value Range and Step Length


 Value Range: Enum (0, 40, 64, 80, 100, 128, 160, 256, 320, 480, 512, 640, 1024, 1280,
2560, 5120) Unit: ms

 Configuration Principles
 This parameters is used to determine the time required for reporting an event, at which
the measured value meets the event reporting criteria.
 The UE will trigger an event reporting only when the actual time reaches the threshold of
this parameter. This parameter is introduced to prevent the UE from any fraudulent
reporting caused by jitter. When configuring this parameter, you need to take the DRX
cycle into consideration.
 You can set this parameter to a greater value for a low-speed cell. This can avoid any
Pingpong reporting of measurement results due to signal jitter.
Internal Use Only▲

Handoff Parameters
 Hysteresis

 Parameter Description
This parameter specifies the hysteresis for event reporting decision in order to avoid jitter.

 Value Range and Step Length


 Value Range: Enum (0, 0.5, …, 15) Step: 0.5 Unit: dB

 Configuration Principles
 Setting this parameter to a too large value will increase difficulty in triggering an
event; however, setting this parameter to a too small value will result in the
Pingpong effect.
 This parameter is comparable to the A3 Offset parameter. Meanwhile, it can be
used to avoid frequent measurement reporting.
Internal Use Only▲

Handoff Parameters
 Report On Leave

 Parameter Description
This parameter indicates an A3 event is leaving. It can be used to determine whether the
UE needs to report an event when the A3-2 criteria is satisfied.

 Value Range and Step Length


 Value Range: Enum (false, true)
 Default Value: false

 Configuration Principles
 When this parameter is set to true, the UE will report an event if a cell meets the
A3-2 criteria.
 You do not need to set this parameter is set to true if handoff is triggered by only
one measurement event reporting.
 This parameter is valid for the ICIC feature, in which case you need to set this
parameter to true so that the base station can monitor the UE’s profile change.
Internal Use Only▲

Potrebbero piacerti anche