Hazardous Gas Alarm System

Detecting hazardous gases on drilling and service rigs is critical.


The Pason Hazardous Gas Alarm System is a rugged warning
system designed to detect lower explosive limit (LEL) and hydrogen
sulfide (H2S) gases by providing visible and audible alerts.

Function
The Pason Hazardous Gas Alarm System operates with Pason’s
Electronic Drilling Recorder (EDR) and Electronic Service Recorder
(ESR). If a hazardous rig atmosphere is detected, the system
reacts immediately, sounding an alarm and flashing a strobe light.
The system then posts a memo to the Pason’s EDR or ESR
Technology permanent log stating when the alarm occurred. LEDs on the main
control unit pinpoint the location of the alarms, sensor status, and
potential equipment malfunctions.

Features
• Fully compatible with Pason’s EDR and ESR.
• Real-time and constantly recorded, values can be viewed on field
workstations and on the Pason DataHub.
• Easy-to-use and highly functional.
Deployed
• Rig tough. The Pason Hazardous Gas Alarm can be
disconnected, moved with the rig, and reconnected in seconds
by the rig crew with minimal training.
• Low maintenance. The H2S sensor requires calibration once
per year and the LEL sensor only requires calibration once every
two years.

Simply
Hazardous Gas Alarm System

Components

Status Location 1
hazardous gas alarm

Location 2 Location 3 Location 4


Main control unit:
Power

Enabled

Fault
FLOOR SUB
Mounts near the driller’s console and has status and alarm
H2S H2S H2S H2S
Mute
LEL

ALARM
LEL

ALARM
LEL

ALARM
LEL

ALARM
LEDs for all sensors in use.
tech support
1-877-255-3158

Light and horn:


The horn has a 117 decibel rating and the light has a two
million peak candlepower lamp. Up to two light and horn
modules can also be connected.

LEL and H2S sensors:


The LEL sensor has two selectable ranges for low and
high values of alarm: 10%/20% or 20%/40%. At the lower
alarm value, the light flashes and the horn “chirps”. At the
RUN

upper alarm value, the light flashes and the horn sounds
FAULT CALIBRATED

RX RIGNET 1 TX

RX RIGNET 2 TX
SENSOR 1 2 3 4
ID #

continuously. The H2S sensor alarms at concentrations


greater than 7.5 ppm (parts per million).

Technology Deployed Simply


At Pason, we design technology that is simple to deploy, use, and maintain.
And we back it up with the industry’s best standard of care. This translates
www.pason.com into increased rig uptime, improved efficiency, and reduced operating costs.
At the rig, in the office, or on the go, Pason makes technology work. Simply.

For more detailed information about any of our services, contact the Pason sales team by visiting our website at
www.pason.com
DOCU127 Hazardous Gas Alarm Brochure (rev 4)