Sei sulla pagina 1di 12

Product Specification of IPX-21 series module

Product Specifications

IPX-21FO 4-Port FXO Module For IPX-2100/IPX-2500

IPX-21SL 2-Port FXS / 2-Port FXO Module For IPX-2100/IPX-2500

IPX-21GS 4-Port GSM Module For IPX-2100/IPX-2500

IPX-21PR 1-Port ISDN Module For IPX-2100/IPX-2500 (Primary Rate Interface)

IPX-21BR 4-Port ISDN Module For IPX-2100/IPX-2500 (Basic Rate Interface)

Version 1.0

This document contains confidential proprietary information and is property of PLANET. The contents of
this document should not be disclosed to unauthorized persons without the written consent of PLANET.

Change History:
Revision Date Author Change List
Version 1.0 2016/6/30 Esther Weng Initial release

Author Esther Weng Editor: Esther Weng


Reviewed by: Jonas Yang Approved by: Kent Kang
Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

1. PRODUCT DESCRIPTION
1.1 FXO (Foreign Exchange Office)
The Analog Trunk FXO is an interface that connects to a trunk line, like the one from your service provider.
It receives ringing voltage and battery from FXS devices. FXO interfaces are used to connect your PBX to
the PSTN. One FXO channel is required for each line you receive from your telco. The Analog Trunk FXO
provides connectivity to analog central office loop start trunk line analog interfaces. And it can be combined
with BRI, PRI and GSM module. Typically, a phone is connected to a loop start line from the Telco and is,
by default, in an on-hook state. When the phone goes off-hook, the phone completes the line circuit and
current flows through the line. The Telco provides an audible dial tone to the phone and accepts dual-tone
multi-frequency (DTMF) digits from the caller. The Central Office Interface Circuit (COIC) is the heart of the
loop start Analog interface, and takes the place of a telephone when connecting to the Telco. The loop
start Analog Interface provides the following features:
y Detects ringing when on-hook
y Detects loop current when off-hook
y Detects tip/ring voltage crossing a set voltage when on-hook or off-hook (called DC triggering)
y Can accommodate private branch exchange (PBX) with -48V battery voltage
y Loop current range: 13~110mA
y Voltage detection threshold is software-selectable

The IPX-21FO module applies to PLANET IPX-2100/IPX-2500, IPX-2200, IPX-2100v2/IPX-2500v2 IP PBX


System. It has 4 RJ11 ports for PSTN line connection. Each port has one LED (light-emitting diode).

The LED indicates port status:


■ Solid Red = Module loading successful
■ Blink Red = Channel will ring if the LED is off, or the loading of the FXO module fails.

All four ports on PLANET IPX-21FO module bracket are 6P4C RJ11 ports. The pin assignments are
indentified in Table 1.

Table 1: RJ11 Telco Port Connector

Filename: PS-IPX-21xx module_v1.0.doc Page 2 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

1.2 2FXO + 2FXS (Foreign Exchange Office & Foreign Exchange Station)
2FXO + 2FXS is mixed interface of foreign exchange office and foreign exchange station that connect to
office and station. It includes 2 FXO ports and 2 FXS ports, and can be combined with BRI, PRI and GSM
module. FXO interfaces are used to connect your PBX to the PSTN. One FXO channel is required for each
line you receive from your telco. FXS interfaces are used on the inside of your PBX; they do not connect
directly to the PSTN. One FXS channel is required for each telephone that you wish to connect to your
Asterisk system.

The Analog Station Interface (FXO) provides the following features:


y Ring Generation and Ringing Trip
y Loop Closure Detection
y Loop Disconnect
y Loop Reversal
y Loop Voltage and Current Monitoring
y On-hook and Off-hook Transmission
y Hook-flash Detection
y DTMF Signalling
y Programmable Audio Gain
y On-board Power Generation
y Constant Loop Current: 20mA

The loop start Analog Interface (FXS) provides the following features:
y Detects ringing when on-hook
y Detects loop current when off-hook
y Detects tip/ring voltage crossing a set voltage when on-hook or off-hook (called DC triggering)
y Can accommodate private branch exchange (PBX) with -48V battery voltage
y Loop current range: 13~110mA
y Voltage detection threshold is software-selectable

The IPX-21SL module applies to PLANET IPX-2100/IPX-2500, IPX-2200, and IPX-2100v2/IPX-2500v2 IP


PBX System with 4 RJ11 ports for connection.
Each port has one LED (light-emitting diode), which is assembled on the main board.
FXS -- Green LED indicates port status:
■ Solid Green = Module loading successful
■ Blink Green = Ringing
FXO -- Red LED indicates port status:
■ Solid Red = Module loading successful

Filename: PS-IPX-21xx module_v1.0.doc Page 3 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

■ Blink Red = Ringing if the LED is off, or the loading of the module fails.

All four ports on PLANET IPX-21SL module bracket are 6P4C RJ11 ports. The pin assignments are
indentified in Table 1.

Table 1: RJ11 Telco Port Connector

Filename: PS-IPX-21xx module_v1.0.doc Page 4 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

1.3 GSM (Global System for Mobile Communications)


Designed with SIM900 for global market, SIM900 is a quad-band GSM engine that works on frequencies
like GSM 850MHz, EGSM 900MHz, DCS 1800MHz and PCS 1900MHz.

SIM900 key features


Feature Implementation
Power supply Single supply voltage 3.4V~4.5V
Power saving Typical power consumption in SLEEP mode is 1.5Ma (BS-PA-MFRMS=5)
Frequency Bands SIM900 quad-band: GSM850, EGSM 900, DCS 1800, PCS 1900. The
SIM900 can search the 4 frequency bands automatically. Compliant to GSM
Phase 2/2+
GSM class Small MS
Transmitting power Class 4 (2W) at GSM 850 and EGSM 900
Class 1 (1W) at DCS 1800 and PCS 1900
Temperature range Normal operation: -30~80 degrees Centigrade

GSM Module Specification


Model No 4 GSM
Number of Quad Band GSM channels per module 4
External antennas 4
SIM Cards Total 4 (internally accessible)

The 4 GSM modules apply to PLANET IPX-2100/IPX-2500, IPX-2200, and IPX-2100v2/IPX-2500v2 IP


PBX System. Each port has one LED (light-emitting diode), which is assembled on the mainboard.

The LED indicates port status:


■ Solid Red = Module loading successful
■ Blink Red = Channel will ring if the LED is off, or the loading of the GSM module fails.

Filename: PS-IPX-21xx module_v1.0.doc Page 5 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

1.4 ISDN Basic Rate Interface (BRI) overview


ISDN Basic Rate Interface (BRI) is a digital connection that provides three digital channels. These
channels consist of two 64 kbps Bearer channels (B-channels) and one 16 kbps signaling channel
(D-channel). This 2B+D connection is known as a Digital Subscriber Loop (DSL). The DSL can be
configured to provide line access, trunk access, or packet data transmission. Line Access provides a digital
connection from a system ISDN BRI card to ISDN terminals that comply with CCITT, ANSI, ETSI NET-3
and ETS 300 403 (including EuroISDN), INS NET-64 (including Japan D70), National ISDN-1 (NI-1), 1TR6,
and Numerics VN2 standards; for example, terminals are telephone sets, fax machines, personal
computers, and video display terminals. Trunk Access provides Meridian Customer Defined Network
(MCDN), TIE trunk connectivity between Large and Small Systems, QSIG ISDN BRI trunk connectivity,
and CO/DID trunk connectivity to local exchanges that support Numeris VN3, 1TR6, ETSI NET-3 and ETS
300 403 (EuroISDN), INS NET-64 (including Japan D70), Australia ETSI, and Asia-Pacific protocols.

General ISDN BRI capabilities


The most important capabilities of ISDN BRI are:
■ For line access
o Simultaneous voice and circuit-switched data over a single DSL
o B-channel and/or D-channel packet data transmission over a single DSL
o Multiple physical terminals connected to a single DSL
o Multiple logical devices associated with each DSL
o Diverse ISDN-compliant third-party terminals (compliant with CCITT, ANSI, ETSI NET-3
and ETS 300 403, INS NET-64, National ISDN-1, 1TR6, Numerics VN2, and EuroISDN
standards)
■ For trunk access - MCDN ISDN BRI TIE trunk connectivity
o QSIG ISDN BRI TIE trunk connectivity
o CO/DID trunk connections to local exchanges that support Numerics VN3, 1TR6, ETSI
NET-3 and ETS 300 403 (EuroISDN), INS NET-64 (Japan D70), Australia ETSI, and
Asia-Pacific protocols

IPX-21BR module applies to PLANET IPX-2100v1/IPX-2500v1, IPX-2200 IP PBX systems. IPX-21BR


module has four BRI ports; each port has one LED (light-emitting diode), which is assembled on the main
board.

The Red LED indicates port status:


■ > Solid Red = TE Model
The Green LED indicates port status:
■ > Solid Green = NT Model
If the LED is off, or the loading of the module fails, it will ring.

Filename: PS-IPX-21xx module_v1.0.doc Page 6 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

Applicable Slot for BRI Module:


Model/Slot Slot 1 Slot 2
IPX-2100v1 Yes No
IPX-2100v2 - -
IPX-2200 No Yes
IPX-2500v1 No Yes
IPX-2500v2 No Yes

Note:
■ Old IPX-21BR module CANNOT be inserted to IPX-2200 and IPX-2500v2.
■ New IPX-21BR module CAN be inserted ONLY to SLOT 2 of IPX-2200, IPX2500v2 and
IPX-2100v1; CAN be inserted ONLY to SLOT 1 of IPX-2100v1.
■ If you need to use the new IPX-21BR module on IPX-2100v1/IPX2500v1, please adjust the jumper
to v1.

BRI Port Jumper Instruction

On PLANET IPX-21BR module, the jumper is on different position for 1/2 port and 3/4 port. The user
should do the following to detect which position is applicable for local standard.
(1) Connect the BRI module correctly and boot up the device
(2) In GUI, set mode for the channels you need to work (Don’t check EC when there’s no EC).
(3) Connect the line to 1/2 and check if it’s working properly or not
(4) When it’s working, then change jumper on 3/4 to 1/2 position
(5) When it’s not working, change jumper on 1/2 to 3/4 position

Filename: PS-IPX-21xx module_v1.0.doc Page 7 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

1.5 ISDN Primary Rate Interface (PRI) overview


ISDN Basic Rate Interface (BRI) is a digital connection that provides three digital channels. These
channels consist of two 64 kbps Bearer channels (B-channels) and one 16 kbps signaling channel
(D-channel). This 2B+D connection is known as a Digital Subscriber Loop (DSL). The DSL can be
configured to provide line access, trunk access, or packet data transmission. Line Access provides a digital
connection from a system ISDN BRI card to ISDN terminals that comply with CCITT, ANSI, ETSI NET-3
and ETS 300 403 (including EuroISDN), INS NET-64 (including Japan D70), National ISDN-1 (NI-1), 1TR6,
and Numerics VN2 standards; for example, terminals are telephone sets, fax machines, personal
computers, and video display terminals. Trunk Access provides Meridian Customer Defined Network
(MCDN) TIE trunk connectivity between Large and Small Systems, QSIG ISDN BRI trunk connectivity, and
CO/DID trunk connectivity to local exchanges that support Numerics VN3, 1TR6, ETSI NET-3 and ETS
300 403 (EuroISDN), INS NET-64 (including Japan D70), Australia ETSI, and Asia-Pacific protocols.

The Primary Rate Interface (PRI) is a standardized telecommunications service level within the Integrated
Services Digital Network (ISDN) specification for carrying multiple DS0 voice and data transmissions
between a network and a user. PRI is the standard for providing telecommunication services to offices. It is
based on the T-carrier (T1) line in the US and Canada, and the E-carrier (E1) line in Europe. The T1 line
consists of 24 channels, while an E1 has 32.

PRI provides a varying number of channels depending on the standards in the country of implementation.
In North America and Japan, it consists of 23xB (B channels (be/s). In Europe and Australia, it is 30xB +
1xD on an E1 2.048 Mbit/s. One timeslot on the E1 is used for synchronization purposes and is not
considered to be a B or D channel.

Primary Rate Interface is for large organizations with 30 bearer channels and 2xD (D channel [delta
channel] [23 64-kbit/s digital channels + 1 64-kbit/s signaling/control channel) on a T1 [1.544 Mbit (PRI]),
for larger applications. Both rates include a number of B-channels and a D-channel. Each B-channel
carries data, voice, and other services. The D-channel carries control and signaling information.

Filename: PS-IPX-21xx module_v1.0.doc Page 8 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

The Primary Rate Interface (PRI) consists of 23 64-kbit/s B-channels and one 64-kbit/s D-channel using a
T1 line, often referred to as "23B + D", (North American and Japanese standard) or 30 B-channels and two
D-channels using an E1 line (Europe/rest of world), often referred to as "30B + 2D". A T1 Primary Rate
Interface user would have access to a 1.472-Mbit/s data service. An E1 Primary Rate Interface user would
have access to a 1.920 Mbit/s data service. Larger connections are possible using PRI pairing.

1PRI module applies to PLANET IPX-2200, IPX-2500v2, IPX-2500v1 and IPX-2100v1 IP PBX system with
one port. This port has four LEDs (light-emitting diodes), which is assembled on the mainboard.

Note:
The jumper on the PLANET IPX-2200, IPX-2100v1 and IPX-2500v2 is in the “Slave” mode; the jumper on
the PLANET IPX-2100v1 is in the “Master” mode. IPX-21PR Module CANNOT be inserted to SLOT 2 of
IPX-2100v1.

LED 1 indicates port status LED 2 and LED 3 indicate port status
Solid Red = Module loading succeeded L2 Solid Red/L3 Off = CPE signaling
Off = Module loading failed L2 Solid Green/L3 off = NET signaling
The LED 4 indicates port status L3 Solid Red/L2 Off = Mfcr2 signal
L3 Solid Green/L2 Off = SS7 signaling
Red = Disconnected (Alarm)
Off = No signal
Green = Connected (No alarm)

Filename: PS-IPX-21xx module_v1.0.doc Page 9 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

2. Specifications
2.2 Functional Specifications
IPX-21FO
Product
4-Port FXO Module For IPX-2100/IPX-2200/IPX-2500
Environmental Operation Information
Temperature 0°C ~ 40°C
Humidity 5% ~ 95% non-condensing
Physical Dimensions 88.5 x 132 x 25 mm
Emission CE, FCC, RoHS

IPX-21SL
Product
2-Port FXS / 2-Port FXO Module For IPX-2100/IPX-2200/IPX-2500
Environmental Operation Information
Temperature 0°C ~ 40°C
Humidity 5% ~ 95% non-condensing
Physical Dimensions 88.5 x 132 x 25 mm
Emission CE, FCC, RoHS

IPX-21GS
Product
4-Port GSM Module For IPX-2100/IPX-2200/IPX-2500
Environmental Operation Information
Temperature 0°C ~ 40°C
Humidity 5% ~ 95% non-condensing
Physical Dimensions 88.5 x 132 x 25 mm
Emission CE, FCC, RoHS

IPX-21BR
Product
4-Port ISDN Module For IPX-2100/IPX-2500 (Basic Rate Interface)
Environmental Operation Information
Temperature 0°C ~ 40°C
Humidity 5% ~ 95% non-condensing
Physical Dimensions 88.5 x 132 x 25 mm
Emission CE, FCC

IPX-21PR
Product
1-Port ISDN Module For IPX-2100/IPX-2500 (Primary Rate Interface)
Environmental Operation Information
Temperature 0°C ~ 40°C
Humidity 5% ~ 95% non-condensing
Physical Dimensions 88.5 x 132 x 25 mm
Emission CE, FCC

Filename: PS-IPX-21xx module_v1.0.doc Page 10 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

2.3 Physical Specifications


¾ Dimensions
Dimensions (W x D x H) 88.5 x 132 x 25 mm
Net weight 92g (without package)

¾ Front Panel
IPX-21FO (4FXO)

IPX-21SL (2FXO+2FXS) IPX-21GS (4GSM)

IPX-21PR IPX-21BR

2.4 Environmental Specifications


Operating
Temperature 0°C ~ 40°C

2.5 Regulatory Compliance


CE, FCC

Filename: PS-IPX-21xx module_v1.0.doc Page 11 of 12 Printed on 2016/6/30


Product Specification
ProductofSpecification
IPX-21 series module
of IPX-330

Confidential

2.6 Package Information


Dimensions (W x D x H) 88.5 x 132 x 25 mm
Weight 92g (gross weight), 122g (with package)

Filename: PS-IPX-21xx module_v1.0.doc Page 12 of 12 Printed on 2016/6/30