N2510 FTU Datasheet

Overview

An FTTx test unit (FTU) is a major device in the


iManager N2510 system to perform test tasks.
It provides OTDR tests. By detecting the
backscattered energy (generated as a result of
Rayleigh scattering and Fresnel reflection during Dimensions (H x W x D) 43.6 mm x 442 mm x 220 mm
light transmission in the fiber) distribution, the FTU
Humidity 5% RH to 95% RH
measures optical link attenuation, identifies events,
and locates a fault. Working Temperature 25 C to +60 C
The FTU tests long optical fibers on the
Storage Temperature 40 C to +70 C
transmission network and manages OTAUs.
It can be installed at the source end or destination Net Weight 3.7 kg
end of an optical fiber and supports only backward
Raman amplifiers. Applicable Subrack 19-/21-inch subrack

Maximum Power Consumption 48.5 W


Board Slot
Voltage 38.4 V DC to 72 V DC

Reserved or WDM board (optional) TCEM board (mandatory)


Provides 4 optical channels Controls tests and communicates
OTBN board (mandatory) with the N2510.
Fan board (mandatory) and multiplexes/demultiplexes Supports test bus access
optical signals. and optical line tests.
OSIC board (optional):
PIU board (mandatory) Provides 16 optical channels.

Slot 3 Slot 4
Slot 5 Slot 6
Slot 1 Slot 2
Note:
In the transmission networking scenario, users need to install an OSIC board in slot 4.
In the active fiber optic transmission testing scenario, if the number of test links is less than four, users can install a WDM board in slot 1
instead of a WDMU.
If the OTBN board is of version A, the OTBN board provides only an OPITCAL port.

OTDR Test Parameters


OTDR Capability
Maximum EDFA Output Power of the
Scenario
Test Wavelength 1625 nm 10 nm Dynamic Range Transmission System
Active fiber monitoring and test 27 dB 23 dBm
Event Dead Zone 0.5 m (3 ns) (The FTU is deployed at the
optical signal transmit end.) 30 dB 20 dBm
Attenuation Dead Zone 2 m (3 ns) Active fiber monitoring and test 23 dBm
(The FTU is deployed at the 36 dB
Dynamic Range 45 dB (20000 ns) optical signal receive end.)

Remarks: Specifications
1. The dynamic range determines the maximum length of 3 ns, 5 ns, 10 ns, 30 ns, 100 ns, 300 ns,
optical fibers that can be tested. When the attenuation is Test Pulse Width 1 us, 2 us, 10 us, and 20 us
fixed, a larger dynamic range indicates that a longer optical
4 km, 8 km, 12 m, 20 km, 40 km, 80 km,
fiber can be tested.
Test Range 120 km, 160 km, 240 km, 320 km, 400
2. Active fiber monitoring and test conditions: km, and 480 km
a) 10 Gbit/s services use the NRZ cording format, and the
FEC is less than or equal to 1.00E-05. Sampling Resolution 2 m, 1 m, 0.5 m, 0.1 m, and 0.033 m
b) 100 Gbit/s services use the SDFEC2 cording format, and Test Distance Difference
1 m resolution 0.0025% x test
the FEC is less than or equal to 1.00E-02. distance
c) The test pulse width is 10,000 ns. Fault Dead Zone from the
50 m (10 ns)
3. The test pulse width in the dark fiber monitoring and test Start End
scenario is 20,000 ns.
Maximum Sample Points 1,600,000 V200R016C00 and later)

N2510 Hardware Datasheet -4-