STATUS ON
STATUS OFF
CHANNEL
Protocol CHANNEL
Convertors
CHANNEL
STATUS ON
STATUS OFF
FCCM/3
Feeder Control & Communication Module
Inputs : Maximum 64 Optically Isolated
Potential Ridden Contacts
divided into 4 groups with
common return, which are used
for monitoring various Status &
Alarms of the Sub-Station.
FCCM/2 & 4 Measurement Accuracy : All Events are time
stamped with 1msec Accuracy.
Feeder Control & Communication Module Auxiliary Supply:18-52 V DC/AC or 77-250 V
DC/AC or +12 & +24VDC.
Input : 1 Amp / 5 Amp. Internal Memory : Buffer for upto 256 Events,
Burden on CT : Less then 0.1 VA. in case of Communication
Burden on PT : Less then 2 VA. failure.
Measured Values : 3φ Current / Voltage. Type Test : As per IEC 60255 standard.
3φ Power Factor / Phase Angle. Communication Ports : Options of Rs485,
Power - Active, Reactive & RS232, Fiber-optic or Ethernet
FCCM/DR
Apparent connections. Feeder Control & Communication Module
Energy - Import & Export Communication Protocols : IEC-870-5-103 with Disturbance Recorder
Power Line Frequency. or 'ASCADA' Ashida proprietary. Input : CT Secondary 1 Amp / 5 Amp.
8 Status inputs. Cutout : 138 x 280 mm. PT Secondary 110 V
Measurement Accuracy 8 Digital Status input.
: Class 1. (or better on request) FCCM/5 Burden on CT : Less then 0.1 VA.
Auxiliary Supply: 18-52 V DC/ AC or 77-250 V Outputs : Maximum 32 Potential free NO Burden on PT : Less then 2 VA.
DC/AC or +12 & +24VDC. Contacts divided into 4 groups Measured Values : 3φ Voltage + Open Delta
Burden on Auxiliary Supply : Less then 10 VA. which are used for Control Voltage. 3φ Current+Neutral-
Control Contacts: 8 sets of potential free NO operation of various Electrical Earth Current. 8 Status.
Contacts for control operation. Mechanisms of the Sub-Station. Recording Resolution : 1 msec Sampling.
Type Test : As per IEC 60255 standard. Auxiliary Supply:18-52 V DC/AC or 77-250 V Auxiliary Supply : 18-52 V DC/AC or 77-250 V
Thermal Withstand : 200 Amp for 3 sec. DC/AC or +12 & +24VDC DC / AC or +12 & +24VDC.
Communication Ports : Options of RS485, Contact Rating:Alarm Duty (should be used Noise Interference : Complies with IS:8686.
RS232, Fiber- optic or Ethernet along with auxiliary tripping relay Environment Test : Damp heat cycle test as
connections. to operated CB coil directly). per IS:9000.
Communication Protocols:IEC-870-5-103 or Insulation: As per IS:3231/ IEC 255. Thermal Withstand : 200 Amp for 3 sec.
'ASCADA' Ashida proprietary. Impulse Test : As per IS:8686 / IEC 255. Type Test : As per IEC 60255 standard.
Cutout : 138 x 280 mm. Communication Ports : Options of Rs485, Communication Ports : Options of Rs485,
FCCM4 Specification RS232, Fiber-optic or Ethernet RS232, Fiber-optic or Ethernet
This Module is similar to FCCM/2 Module in connections connections
addition, having extra Analogue Input for Communication Protocols : IEC-870-5-103 Communication Protocols : IEC-870-5-103
monitoring Transformer Oil Temperature, or 'ASCADA' Ashida proprietary. or 'ASCADA' Ashida proprietary.
Winding Temperature & other 4-20 mA Inputs Cutout : 138 x 280 mm. Cutout : 138 x 280 mm.