Feeder Protection Relay A DR 2 41 B


CHANNEL
ON

PKP

FAULT ANSI IEC PROTECTION FUNCTIO


50 N
I>> INSTANTANEOUS OVE RS 232
R CURRENT
50N IE>>
RSP/LC INSTANTANEOUS EART
H FAULT
50, 51 I>t, Ip TIME OVER CURRENT
(PHASE)
50N, 51N IE>t, IEP TIMR OVER CURRENT
STATUS ON TRIP 79
(EARTH)
AUTO RECLOSER
STATUS OFF 74TC TRIP CIRCUIT SUPER VI
BREAKER CONT SION.
ROL

ASHIDA ASCADA-SAS Systems


Keeping an eye on your valuable systems
digitally

CHANNEL

CHANNEL

CHAN
N EL

CHANNEL

STATUS ON

STATUS OFF

ASCADA-SAS Substation Automation System


With the opening of the electrical utility market, Sub-station
Automation or SCADA systems have now changed from
‘Luxury’ to ‘Necessity’. Exorbitant prices however have always
been a hurdle in implementing a SCADA scheme. But now
advancements in Electronics & Software field, coupled with
ASHIDA design has made it possible to implement a
sophisticated system to monitor & control a satellite substation
from a central location, without a high price-tag normally can be monitored from a single location. The recorded data is
associated with such systems. ASHIDA is not just a ‘SCADA used to generate reports like Hourly logs, Energy audit reports,
System Integrator’ but a complete solution provider. The tight Occurrence reports, Event Sequence report & various other
integration of Ashida Software & Hardware modules has had analytical reports.
a definite impact on the overall quality & economy of the
Further Ashida ASCADA integrates with protection relays/ IEDs
system.
from various vendors, which support standard protocols to
In a simple ASCADA-SAS scheme, the ASCADA-SAS Software provide additional protection data & powerful fault analysis. It
communicates with FCCM modules installed on individual is possible to forward all parameters to a central control or to a
bays. Various options are available for communication. All separate system like GIS. Additional ‘client’ software can be
such information collected from various modules is then installed on a separate PC for analysis. For critical installations,
processed, recorded & presented to the user in easily redundant server configuration is an option. The system can
understandable formats. The user has an option to control also connect to a GPS timeserver for Time synchronisation
individual bays based on this data. Multiple such sub-stations between all IEDs.

Features of ASCADA-SAS system


Hardware (FCCM) Features:
> RTU/ Transducer-less operation. All parameters measured > Reports generated can be exported to standard ‘office’
by a single Intelligent Electronic Device. formats.
> Lifetime calibration of measuring circuit. No need for > Can support multiple sub-stations & ‘clients’.
frequent calibration. > Can support multiple party IED with IBC-103, DNP3 or
> High Thermal withstand capacity. All field instruments can MODBUS protocol.
measure more than 100 Amps of current for 3 Sec.
> In-built real-time clock enables time stamping of System Features
parameters before storing. > High Performance at affordable prices.
> Hardware ports supported include RS-485, Fiber-optic & > ‘Clean’ implementation. Very few wires need to be wired
Ethernet. around the sub-station.
> Protocols supported are IEC60870-5-103 & ‘ASCADA’ > System can work over wide range of communication
proprietary. mediums.
> Can be installed in incremental implementation.
Software Features Installation can start with small number of monitoring
> Intuitive GUI based software needs minimal training for points & later on can be expanded to increase the scope.
usage. All this by simply adding new modules.
> Onsite configuration of Mimic & report formats.
CHANNEL

CHANNEL

Protocol CHANNEL

Convertors
CHANNEL

STATUS ON

STATUS OFF

FCCM/3
Feeder Control & Communication Module
Inputs : Maximum 64 Optically Isolated
Potential Ridden Contacts
divided into 4 groups with
common return, which are used
for monitoring various Status &
Alarms of the Sub-Station.
FCCM/2 & 4 Measurement Accuracy : All Events are time
stamped with 1msec Accuracy.
Feeder Control & Communication Module Auxiliary Supply:18-52 V DC/AC or 77-250 V
DC/AC or +12 & +24VDC.
Input : 1 Amp / 5 Amp. Internal Memory : Buffer for upto 256 Events,
Burden on CT : Less then 0.1 VA. in case of Communication
Burden on PT : Less then 2 VA. failure.
Measured Values : 3φ Current / Voltage. Type Test : As per IEC 60255 standard.
3φ Power Factor / Phase Angle. Communication Ports : Options of Rs485,
Power - Active, Reactive & RS232, Fiber-optic or Ethernet
FCCM/DR
Apparent connections. Feeder Control & Communication Module
Energy - Import & Export Communication Protocols : IEC-870-5-103 with Disturbance Recorder
Power Line Frequency. or 'ASCADA' Ashida proprietary. Input : CT Secondary 1 Amp / 5 Amp.
8 Status inputs. Cutout : 138 x 280 mm. PT Secondary 110 V
Measurement Accuracy 8 Digital Status input.
: Class 1. (or better on request) FCCM/5 Burden on CT : Less then 0.1 VA.
Auxiliary Supply: 18-52 V DC/ AC or 77-250 V Outputs : Maximum 32 Potential free NO Burden on PT : Less then 2 VA.
DC/AC or +12 & +24VDC. Contacts divided into 4 groups Measured Values : 3φ Voltage + Open Delta
Burden on Auxiliary Supply : Less then 10 VA. which are used for Control Voltage. 3φ Current+Neutral-
Control Contacts: 8 sets of potential free NO operation of various Electrical Earth Current. 8 Status.
Contacts for control operation. Mechanisms of the Sub-Station. Recording Resolution : 1 msec Sampling.
Type Test : As per IEC 60255 standard. Auxiliary Supply:18-52 V DC/AC or 77-250 V Auxiliary Supply : 18-52 V DC/AC or 77-250 V
Thermal Withstand : 200 Amp for 3 sec. DC/AC or +12 & +24VDC DC / AC or +12 & +24VDC.
Communication Ports : Options of RS485, Contact Rating:Alarm Duty (should be used Noise Interference : Complies with IS:8686.
RS232, Fiber- optic or Ethernet along with auxiliary tripping relay Environment Test : Damp heat cycle test as
connections. to operated CB coil directly). per IS:9000.
Communication Protocols:IEC-870-5-103 or Insulation: As per IS:3231/ IEC 255. Thermal Withstand : 200 Amp for 3 sec.
'ASCADA' Ashida proprietary. Impulse Test : As per IS:8686 / IEC 255. Type Test : As per IEC 60255 standard.
Cutout : 138 x 280 mm. Communication Ports : Options of Rs485, Communication Ports : Options of Rs485,
FCCM4 Specification RS232, Fiber-optic or Ethernet RS232, Fiber-optic or Ethernet
This Module is similar to FCCM/2 Module in connections connections
addition, having extra Analogue Input for Communication Protocols : IEC-870-5-103 Communication Protocols : IEC-870-5-103
monitoring Transformer Oil Temperature, or 'ASCADA' Ashida proprietary. or 'ASCADA' Ashida proprietary.
Winding Temperature & other 4-20 mA Inputs Cutout : 138 x 280 mm. Cutout : 138 x 280 mm.
series

Feeder Protection Relay ADR 241 B


ON

PKP

FAULT ANSI IEC PROTECTION FUNCTIO


50 N
I>> INSTANTANEOUS OVE RS 232
R CURRENT
50N IE>>
RSP/LC INSTANTANEOUS EART
H FAULT
50, 51 I>t, Ip TIME OVER CURRENT
(PHASE)
50N, 51N IE>t, IEP TIMR OVER CURRENT
TRIP 79
(EARTH)
AUTO RECLOSER
74TC TRIP CIRCUIT PER VI
BREAKER CONSU
TROL
SION.

series

ASHIDA Numerical Protection Relay


ADITYA Numerical Relay having Common User
Interface & Communication Interface. Various
protection such as OC / EF (IDMT / Definite time)
/ Transformer differential / Directional / Reverse
power / UV / OV can be available.
GENERAL FEATURES AUOFMR2
> RS232 and RS485 Communication port for Numerical Under/Over Frequency
Local / Remote SCADA System Monitoring Relay
> Load parameter on LCD Display
> Accurate Frequency monitoring with
> Latching of fault parameter
Crystal Controlled references.
> Programming Via local keys as well as
> Trip Frequency Point can be selected with
remote programming Via communication
0.01 Hz Resolution.
port .
> Self-Calibration and check ON-Site facility
> Back-lit LCD display for settings & parameter
inbuilt.
display
> Pass-word protection
> Instrument tested to withstand as per Some of the advantages
> Communication with IEC-870 protocol
IS:3231, IS:8686-1977 Specification. of such type of system
> Two Independent set points
> Disturbance recording > Central control over distant processes
programmable as Under or Over
> Tested as per IEC 60255 standard > Accurate & Timely data availability for
Frequency.
> RS232 & RS485 Communication Port for fault analysis. (e.g. a major breakdown).
ASCADA Accessories remote SCADA.
> AC Input from 230/110/63 V AC PT for
> Instant actions can be taken in case of
emergencies
Frequency Sensing. > All substation status report available at the
> Frequency setting Range : 49.99 Hz to main center instantly for the top
40.00 Hz in steps of 0.01 Hz for Under management to take quick decision.
Frequency and 50.01 Hz to 60.00 Hz in > Better management of available
steps of 0,01 Hz for Over Frequency. resources.
> Accuracy Setting : +/- 0.01 Hz Repeat > Preprogrammed response to a event
Accuracy better then 0.05 Hz. possible.
> Delay Time Adjustment : 0 to 99.9 sec > Full utilisation of costly Numeric Relays:
> Isolated RS 232-232 Repeater. Accuracy +/- 5% or +/- 0.02s whichever ASCADA-SAS system will enable full
> Isolated RS 232-485 Convertor. is Higher. utilisation of latest Relay by allowing
> Isolated RS232 -Ethernet Convertor. > Programmable Hysterisis. reading of disturbance data, event from
> Isolated RS 485-485 Repeater. > This Relay is also available with 2 Stage Numeric Protection Relays
> Fiber optics convertor. df/dt and 2 Stage Under/Over Frequency > Unmanning of Substation: with this system
> Port Switches / data concentrators. Features. a 'unmanned' substation controlled from
> AC/DC changeover Power Supply, etc. > Cutout : 186 x 92 mm. a central location become a reality.
Designed by: HEMISPHERE ADVERTISING
Cell: 98200 82678 Tel: 022-2618 6697

ASHIDA
ASHIDA
ELECTRONICS PVT. LTD.
ELECTRONICS PVT. LTD.

‘ASHIDA HOUSE’,
A-308. Road No.21, Wagle Industrial Estate, Thane-400604. INDIA
Tel: 91-22-2582 7524 / 25 / 26, 5577 1076 / 77 / 78
Fax: 91-22-2580 4262 Email: sales@ashidaelectronics.com
www.ashidaelectronics.com

Potrebbero piacerti anche