fiber optic cables fibrain content

Information Page 5
Application Page 5 5
FOC Parameters Page 6
Low Loss Fibers Page 7
SM/MM Bendsafe Fibers Page 9
Page 10
Fiber and Cables Information
Page 11
Fiber Identification

DATACOM Page 17
Furcation tube FSMX Page 17 16
Buffer BFR Page 18
Simplex SMX Page 19
DC-PRIM-14 Page 21
DC-PRIM-20 Page 22
DC-PRIM Page 23
DC-DRIM Page 24
Duplex ZIP Page 25
DC-T40 Page 26
LDC Page 27
LBR Page 28
EXO-FU Page 29
EXO-FI Page 30
EXO-GU Page 31
EXO-G0 Page 32
EXO-GI Page 33
BDC-MSA Page 34

FTTH Page 35
VC-D20 Page 37 35
VC-D30 Page 38
VC-D40 Page 39
VC-DCY Page 40
Resibend® Cables Page 41
VC-D30 Resibend® Page 42
VC-D30 Resibend Plus® Page 43
Easy Section Module® Cables Page 44
VC-D20 Easy Section Module® Page 45
VC-D30 Easy Section Module® Page 46
VC-D40 Easy Section Module® Page 47
DC-PRIM Page 48
EAC-RAs Page 49
EAC-RAm Page 50
DAC-BURRY Page 51
DAC-BURRY-G Page 52
VC-T601-PE Page 53
VC-T60 Page 54

ver. 2.0.6
fiber optic cables fibrain content

MICRODUCT Page 55
MK-AX2 Page 57 55
MK-LX4 Page 58
MK-LX5 Page 59
MK-LXS6/7/8 Page 60
MK-LXS9/10 Page 61
MK-LX6 Page 62
MK-LX7 Page 63
MK-LX8 Page 64
MK-LX9 Page 65
MK-LX11 Page 66

Telecom Duct Page 67


BDC-MSA Page 68 67
BDC-MIB Page 69
BDC-C0 Page 70
BDC-CI Page 71
BDC-CK Page 72
BDC-DI Page 73
BDC-DK Page 74
DDC-SI Page 75
DDC-CI Page 76
MDC-FM Page 77

armored cables Page 78


SSC-CI Page 79 78
SSC-T30U Page 80
SSC-T30I Page 81
DSC-CI Page 82

Telecom Aerial Page 83


Aero-DR03 Page 84 83
Aero-DF03 Page 85
Aero-DDF03 Page 86
Aero-AS02 2.0 mm Page 87
Aero-AS03 2.0 mm Page 88
Aero-AS03 2.5 mm Page 89
Aero-AS04 2.0 mm Page 90
Aero-AS04 2.5 mm Page 91
Aero-AS06 2.0 mm Page 92
Aero-AS06 2.5 mm Page 93
Aero-AS09 2.5 mm Page 94
Aero-AS12 2.5 mm Page 95
Aero-AS14 2.5 mm Page 96

Special Cable Designs Page 97


FTTA-DAC Page 98 82
BDC-CIP 1.5 mm2 Page 99
BDC-CIP 0.5 mm2 H05V-U Page 100
BDC-CIP 0.75 mm2 H05V-U Page 101
BDC-CIP 1.00 mm2 H05V-U Page 102
BDC-DIP 1.50 mm2 H07V-U Page 103
BDC-DIP 2.50 mm2 H05V-U Page 104
BDC-DID 0.80 mm Page 105

ver. 2.0.6
Information
symbols

Rodent
Basic Rodent High Rodent Protection
Protection Protection Extreme Blowing
installation
Mechanical features

Last mile
Flexible connection outdoor Aerial Hi-crush

Duct Microduct
Direct buried Generation 1 ETR

Optimal
Diameter
Branch of business

Industrial Mining Military Oil resistance

Ship Datacenter
Robotic Windfarms
and offshore

Datacom Telecom FTTH FTTA


Design features

Semi-tight LSOH Compact design


Easy-strip

Multifiber
connectors Last Mile
Flexible Easy to terminate Indoor Connection
termination

Hybrid FO
+ Power
Bendsafe Low Friction

fiber optic cables 2017 | 5


FOC parameters FOC Parameters

single-mode fiber types Fiber types and applications


Maximum attenuation for uncabled fibers
Fiber type IL [dB/km]
ITU-IT Tight 900 μm fiber
1310 nm 1383 nm 1410 nm 1450 nm 1490 nm 1550 nm 1625 nm Possibility to remove the 900 μm coat at the
Standard single mode telecommu- distance of 3-5 cm
G.652D nication fiber with zero water-peak ≤0.34 ≤0.31 - - ≤0.24 ≤0.20 ≤0.23
attenuation
Semi-tight 900 μm fiber
Premium single mode fiber low loss
G.652D LL with zero water-peak and lower ≤0.32 ≤0.31 - - ≤0.21 ≤0.18 ≤0.20
Possibility to remove the 900 μm coat at the
attenuation in whole bandwidth distance of 20-40 cm
Long distance single mode fiber
G.655 –
with non-zero dispersion shifted Easy strip 900 μm fiber
A,B,C,D
(NZDSF) for CWDM and DWDM - ≤0.40 ≤0.32 ≤0.26 - ≤0.19 ≤0.21 Possibility to remove the 900 μm coat at the
system 10G
and future 40G or 100G distance more than 100 cm
Long distance single mode fiber
G.656 – with non-zero dispersion shifted
- ≤0.40 ≤0.32 ≤0.26 - ≤0.19 ≤0.21
A,B,C,D (NZDSF) for CWDM and DWDM Available bend radius
system 10G and future 40G or 100G
Bend insensitive fiber fully
G.657A1 compatible with G.652D standard, ≤0.35 ≤0.35 - - ≤0.24 ≤0.20 ≤0.23 [ mm ]
bend radius 10-15 mm
Bend insensitive fiber fully
G.657A2 compatible with G.652D standard, ≤0.35 ≤0.35 - - ≤0.24 ≤0.20 ≤0.23
bend radius 7.5 mm
Bend insensitive fiber fully
G.657B3 compatible with G.652D standard, ≤0.35 ≤0.35 - - ≤0.24 ≤0.20 ≤0.23
bend radius 5 mm 30 G.652
Bend insensitive fiber, compatible
with G.652D standard, for connec- - G.657A1
G.657B3 Plus ≤0.35 ≤0.35 - ≤0.24 ≤0.21 ≤0.23
torization application, bend radius G.657A2/B2
2.5 mm 10
7.5 5 G.657B3
2.5 G.657B3 Plus
multimode fiber types
Overfilled
modal Link Lengths Attenuation Bending loss Bending loss
bandwidth [m] [dB/km] 2 turns [dB] 10 turns [dB]
Fiber [MHz/km]
type
ITU-T 40GBASE- Radius = 7.5 mm Radius = 15 mm Radius = 30 mm
850 1300 SR4/ 850 1300
1GBase-SR 10GBase-SR
nm nm 100GBASE- nm nm 850 1300 850 1300
SR10 850 nm 1300 nm
nm nm nm nm
62.5/125 ≥
≥ 160 275 - - 2.6 0.5 - ≥ 0.5
OM1 500
50/125

OM2 Bend ≥ 500 600 83 - 2.3 0.5 ≥ 0.2 ≥ 0.5 ≥ 0.1 ≥ 0.3 -
500
Insensitive
50/125
≥ ≥
OM3 Bend 1000 300 140* 2.4 0.5 ≥ 0.2 ≥ 0.5 ≥ 0.1 ≥ 0.3 -
1500 500
Insensitive
50/125
≥ ≥
OM4 Bend 1100 550 170* 2.4 0.6 ≥ 0.2 ≥ 0.5 ≥ 0.1 ≥ 0.3 -
3500 500
Insensitive
* Maximum cabled fiber attenuation 3.0 dB/km at 850 nm, maximum total connector loss of 1.0 dB and VCSELs maximum RMS spectral width of 0.29
nm (according to IEEE 10GbE model: http://grouper.ieee.org/groups/802/3/ae/public/adhoc/serial_pmd/documents/10GEPBud3_1_16a.xls).

Bending loss
Mandrel R=30 mm 100 turns Mandrel R=25 mm 1310/1550 nm 100 turns Mandrel R=15 mm 10 turn
G.652D
1550/1625 nm ≤0.03 dB 0.03 dB 1550 nm ≤0.25 dB 1625 nm ≤1.0 dB
Mandrel R=30 mm 100 turns Mandrel R=25 mm 1310/1550 nm 100 turns Mandrel R=15 mm 10 turn
G.652D LL
1550/1625 nm ≤0.03 dB 0.03 dB 1550 ≤0.25 dB 1625 nm≤1.0 dB
Mandrel R=30 mm 100 turns Mandrel R=15 mm 1550/1625 nm 1 turn
G.655 – A.B.C.D
1550/1625 nm ≤0.05dB ≤0.5 dB
Mandrel R=30 mm 100 turns Mandrel R=15 mm 1550/1625 nm 1 turn
G.656 – A.B.C.D
1550/1625 nm ≤0.05 dB ≤0.5 dB
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm
G.657A1
1550nm≥0.20 dB. 1625 nm ≤0.50 dB ≥0.50 dB. 1625 nm ≤1.50 dB
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn
G.657A2
1550 nm≥0.03 dB. 1625nm ≤0.10 dB 1550 nm≥0.10 dB. 1625 nm ≤0.2dB; 1550 nm ≥0.50 dB. 1625 nm ≤1.0 dB

Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn 1550 nm Mandrel R=5 mm 1 turn
G.657B3
1550 nm≥0.03 dB. 1625 nm ≤0.10 dB ≥0.05 dB. 1625 nm ≤0.15 dB 1550 nm≥0.10 dB. 1625 nm ≤0.30 dB
Mandrel R=5 mm 1 turn Mandrel R=2.5 mm 1 turn 1550 nm
G.657B3 Plus
1550 nm≥0.10 dB. 1625nm ≤0.20 dB ≥0.20 dB. 1625 nm ≤0.30dB
low loss fibers Low Loss Fibers

At present, low loss and pure quartz optic fibers with max. 0.17 dB/km The chromatic dispersion complies with ITU-T G.652 and the polari-
attenuation at 1550 nm wavelength and max. 0.31 dB/km at 1310 nm zing at the level of ≤ 0.04 ps/√km of these fibers provides the pos-
wavelength are ready for use. Low loss and pure quartz optic fibers have at sibility of using such fibers in high- speed systems e.g. transmission
least 0.02 dB/km lower spectral attenuation in comparison to the standard of 10 GBit/s or even higher. Low loss fibers which are obtained
ones G.652D. In such fibers, the retention of flat spectral characteristics in the pure quartz technology can work properly in telecommunica-
within the transmission windows provide the possibility of achieving sub- tion networks at the distance of even thousand kilometers far, which
stantially smaller deviations of attenuation: significantly limits the number of necessary amplifiers and repeaters
ÆÆ 1310 nm (+ 20 nm / -35 nm) wavelength – max. deviation is 0.03 in a fiber optic connection.
dB/km
ÆÆ 1550 nm ( + 25 nm / -25 nm) wavelength – max. deviation is 0.02
dB/km with the retention of 1625 nm attenuation 0.20 dB/km.

Attenuation / Wavelength

0.40
Attenuation [dB/km]

0.30

0.20
G.652.D LL

G.652.D LL

G.652.D LL

G.652.D LL

G.652.D LL
G.657.A1

G.657.A1

G.657.A1

G.657.A1

G.657.A1
G.652.D

G.652.D

G.652.D

G.652.D

G.652.D

0.10

0
13

13

14

15

16
10

83

90

50

25

Wavelength [nm]

fiber optic cables 2017 | 7


low loss fibers Low Loss Fibers

Performance Specifications
Parameter Value

Attenuation [dB/km]
1310 nm ≤ 0.32
1383 ± 3 nm ≤ 0.32
1490 nm ≤ 0.21
1550 nm ≤ 0.18
1625 nm ≤ 0.20
Attenuation Difference [dB/km]
λ1 λ2 λ3 Δ
The attenuation from λ1 [nm] to λ2 [nm] shall not exceed the attenu- 1285 1330 1310 0.03
ation at λ3 [nm] by more than Δ
1525 1575 1550 0.02
Point Discontinuity [dB]
1310 nm and 1550 nm ≤ 0.05
Optical Return Loss [dB]
Absolute value at all points along the fiber ≥ 60

Turns mm nm dB
1 32 1550 ≤0.03
Attenuation with Bending [dB] 100 50 1310 ≤0.03
100 50 1550 ≤0.03
100 60 1625 ≤0.03

Cable Cutoff Wavelength [nm] ≤ 1260


Mode Field Diameter [µm]
1310 nm 9.2±0.4
1550 nm 10.4±0.5
Dispersion [ps/(nm•km)]
1550 nm ≤ 18.0
1625 nm ≤ 22.0
Zero Dispersion Wavelength - λo [nm] 1304 to 1324
Zero Dispersion Slope - So [ps/(nm2•km)] ≤ 0.092
Polarization Mode Dispersion (ps/√km)
Individual fiber ≤ 0.1
Link value ≤ 0.04
Environmental / Attenuation Effects (dB/km) 1310 / 1550 / 1625 nm
Temperature Dependence (–60°C to +85°C) ≤ 0.05
Temperature-Humidity Cycling
≤ 0.05
(-10°C to +85°C with humidity cycling up to 98% RH)
Dry Heat Soak (85±2°C) ≤ 0.05
Water Immersion (23±2°C) ≤ 0.05
Damp Heat Soak (85±2°C, 85% RH, 30 Days) ≤ 0.05
Fiber Curl ≤ 0.05
Deflection for 10 mm overhang (µm) ≤12.4
Corresponding radius of curvature (meters) ≥ 4.0
Minimum Strength (by Proof Test) 0.69 GPa (100 kpsi)
Operating Temperature Range -60°C to +85°C

8 | fiber optic cables 2017


SM/MM BENDSAFE FIBERS SM/MM Fibers

Available bend radius

BEND RADIUS BEND RADIUS BEND RADIUS BEND RADIUS BEND RADIUS

2.5 5 7.5 10 30
mm mm mm mm mm

G.657B3 Plus G.657.B3 G.657.A2 and G.657.B2 G.657.A1 G.652D

Bendsafe SM Fibers

G.652D G.652D LL G.655 - A.B.C.D G.656 - A.B.C.D G.657A1 G.657A2 G.657B3 G.657B3 Plus

Max. attenuation for wavelength


60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625 nm/both [dB]


40
0.50dB
0.50dB

0.05dB
0.03dB

0.03dB

0.03dB

0.03dB

0.05dB
Bend radius [mm]

30

15

10

7,5

Bendsafe MM Fibers
50/125 OM2 50/125 OM3 50/125 OM4
Bend Insensitive Bend Insensitive Bend Insensitive
60
Bending loss for wavelength
850nm 1300nm/both [dB]
0.10dB 0.30dB

0.20dB 0.50dB

0.10dB 0.30dB

0.20dB 0.50dB

0.10dB 0.30dB

0.20dB 0.50dB

40
Bend radius [mm]

30

15

10

7,5

fiber optic cables 2017 | 9


FOC fiber and cables information Fiber and cables Information

Post-production fiber parameters Tight buffer vs. Loose tube


Attenuation [dB/km]
Type Loose
1310 1550 850 1300 Tight buffer tube
Low Loss (LL) 0.34 0.22 - -
2-3mm
Telecom 0.35 0.25 - -
900µm
Standard 0.40 0.30 - -
Datacom 0.40 0.30 3.0 (3.5*) 1.0 (1.5*)

* values for OM1 Tube Gel 900 µm outer coating 250 µm coating

Core 125 µm coating

Stripping

Tight buffer Semi-tight Easy strip


Tight 900 μm fiber Semi-tight 900 μm fiber Easy strip 900 μm fiber
Possibility to remove the 900 μm Possibility to remove the 900 μm Possibility to remove the 900 μm
coat at the distance of 3-5 cm coat at the distance of 20-40 cm coat at the distance more than
100 cm

10 | fiber optic cables 2017


FOC fiber identification telecom

Fiber color codes in Loose tube cable design


Other colors available on demand

T-Telecom (according to IEC 60304)


1-12 1 2 3 4 5 6 7 8 9 10 11 12
1
Code 12 2

11 3

Color red green blue white violet orange grey yellow brown pink black aqua 10 4

13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5

8 6
Code 7

Color red green blue white violet orange grey yellow brown pink natural aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

T1-TELecom (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)


1-12 1 2 3 4 5 6 7 8 9 10 11 12
1
2
Code 12

11 3

Color red blue white green violet orange grey yellow brown pink black aqua 10 4

13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5

8 6
Code 7

Color red blue white green violet orange grey yellow brown pink natural aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

T2-TELecom (according to EIA 598A)


1-12 1 2 3 4 5 6 7 8 9 10 11 12
1
12 2
Code
11 3

Color blue orange green brown grey white red black yellow violet pink aqua 10 4

13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5

8 6
Code 7

Color blue orange green brown grey white red natural yellow violet pink aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

fiber optic cables 2017 | 11


FOC fiber in Loose tube color codes telecom

Loose tube color codes in Loose tube cable design


Other colors available on demand

t-telecom - Loose tube in cable (according to iec60304): 12


1
2

Tube 1 2 3 4 5 6 7 8 9 10 11 12 11 3

10 4
Code
9 5

Color red green blue white violet orange grey yellow brown pink black aqua 8
7
6

**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers

t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)
1
Tube 1 2 3 4 5 6 7 8 9 10 11 12 12 2

11 3

Code 10 4

Color red blue white green violet orange grey yellow brown pink black aqua 9 5

8 6
7
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers

t2-telecom - Loose tube in cable (according to EIA 598A)


Tube 1 2 3 4 5 6 7 8 9 10 11 12 12
1
2

11 3

Code
10 4

Color blue orange green brown grey white red black yellow violet pink aqua 9 5

8 6
**In cable with a multi-layer construction color of the tubes will be repeated in second layer 7

***In case of lower fiber count some tubes can be replaced by fillers

t3-telecom - Loose tube in cable according to IEC 60304)


1
Tube 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 2
14 3

Code 13 4

12 5

luminous patina signal


Color red green blue white violet orange grey yellow brown pink black aqua 11 6
red green blue 10 7
9 8
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers

E-telecom - Loose tube in cable (according to EIA 598A)


Tube 1 2 3 4 5 6 7 8 9 10 11 12 1
2

Code

Color red green white white white white white white white white white white
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers

12 | fiber optic cables 2017


FOC fiber color codes datacom

Fiber, buffer and tubes color codes for Datacom cables range
Other colors available on demand

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304)


Fiber in buffer
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Fiber

Buffer

Color red green blue yellow white grey brown violet aqua black orange pink
250/900/600 µm

13-24 13 14 15 16 17 18 19 20 21 22 23 24

Fiber

Buffer

Color red green blue yellow white grey brown violet aqua natural orange pink
250 µm

Color* dark
red green blue yellow white grey brown violet brown orange pink
600/900 µm green

*Buffer with black mark to identifiy fibers 13-24

Fibers in tubes
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code 24
13

1
14
2
23 15

Color red green blue yellow white grey brown violet aqua black orange pink
22 16

13-24 13 14 15 16 17 18 19 20 21 22 23 24 21 17

20 18
Code 19

Color red green blue yellow white grey brown violet aqua natural orange pink

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Loose tubes in cables


Tube 1 2 3 4 5 6 7 8 9 10 11 12
1
12 2
Code 11 3

Color red green blue white violet orange grey yellow brown pink black aqua 10 4

**In cable with a multi-layer construction color of the tubes will be repeated in second layer 9 5

***In case of lower fiber count some tubes can be replaced by fillers 8
7
6

fiber optic cables 2017 | 13


FOC fiber color codes datacom

Fiber and buffer color codes for datacom cables range


Other colors available on demand

D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables)
Fiber in buffer
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Fiber

Buffer

Color blue orange green brown grey white red black yellow violet pink aqua
250/900/600 µm

13-24 13 14 15 16 17 18 19 20 21 22 23 24

Fiber

Code

Color blue orange green brown grey white red natural yellow violet pink aqua
250 µm

Color* dark
blue orange green brown grey white red yellow violet pink aqua
600/900 µm green

*Buffer with black mark to identifiy fibers 13-24

Fibers in tubes
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code 24
13

1
14
2
23 15

Color blue orange green brown grey white red black yellow violet pink aqua
22 16

13-24 13 14 15 16 17 18 19 20 21 22 23 24 21 17

20 18
Code 19

Color blue orange green brown grey white red natural yellow violet pink aqua

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm

Loose tubes in cables


Tube 1 2 3 4 5 6 7 8 9 10 11 12
1
12 2
Code 11 3

Color red green blue white violet orange grey yellow brown pink black aqua 10 4

**In cable with a multi-layer construction color of the tubes will be repeated in second layer 9 5

***In case of lower fiber count some tubes can be replaced by fillers 8
7
6

14 | fiber optic cables 2017


FOC fiber color codes ftth

Fiber and buffer color codes for FTTH cables range


Other colors available on demand

F-FTTH (according to DIN VDE 0888 & IEC 60304)


1-12 1 2 3 4 5 6 7 8 9 10 11 12

Fiber

Buffer

Color red blue green yellow violet white orange grey brown black aqua pink
250 µm

Color red blue green yellow violet white orange grey brown black aqua pink
600/900 µm

13-24 13 14 15 16 17 18 19 20 21 22 23 24

Fiber

Code

Color red blue green yellow violet white orange grey brown black aqua pink
250 µm

Color* dark
red blue green yellow violet white orange grey brown aqua pink
600/900 µm green

*Buffer with black mark to identifiy fibers 13-24

fiber optic cables 2017 | 15


FIBRAIN
COATINGS

Industrial Oil resistance Ship and offshore


Mining

Windfarms Datacenter Telecom


Robotic

Coatings physical properties


PE polyethylene LSOH PVC polyvinyl chloride PUR polyurethane PA polyamide NBR nitrile rubber
Mechanical resistance Mechanical resistance Mechanical resistance Mechanical resistance Mechanical resistance Mechanical resistance

Temperature resistance Temperature resistance Temperature resistance Temperature resistance Temperature resistance Temperature resistance

Chemical resistance Chemical resistance Chemical resistance Chemical resistance Chemical resistance Chemical resistance

16 | fiber optic cables 2017


datacom furcation tube fsmx Furcation tube FSMX 1.6 - 2.8 mm

1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3
3. Central tube 900 μm

TRUE
COLORS

Flexible Easy to Bendsafe


terminate

Configuration

FSMX Applications
Max. installation ÆÆ Distribution systems cable
Ø nominal Nominal weight Crush
Version tension
± 5% [mm] ± 5% [kg/km] [N/10 cm] ÆÆ For patchcords and pigtails
(ε=0.5 %) [N]
ÆÆ Terminals connection
FSMX 1.8 1.8/0.9/0.5 4 100 200
FSMX 2.8 2.8/0.9/0.5 8 350 300

Jacket colors
Features
Standard
ÆÆ LS0H with low coefficient of friction
ÆÆ Aramid yarns
ÆÆ Central tube 900 µm

Yellow RAL 1021 White RAL 9010 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet Low-radius bending resistance SM
RGB 196, 97, 140

[ mm ]
Color codes
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
30 G.652
Fiber
G.657A1
Buffer G.657A2/B2
10
7.5 5 G.657B3
Color red green blue yellow white grey brown violet aqua black orange pink 2.5 G.657B3 Plus
900 µm

Operating temperature

+100
+70°C

+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-10°C

-40°C

-100

fiber optic cables 2017 | 17


datacom Buffer bFR Buffer BFR 0.6 - 0.9 mm

1
2
Cable structure 3

1. Outer tight buffer tube


600/900 µm (LS0H)
2. Colored coating on fiber 250 µm
3. Optical fiber with cladding
125 µm
TRUE
COLORS

Flexible Easy to Semi-tight Easy-strip Bendsafe


terminate

Configuration

BFR Applications
Ø nominal Max. installation Crush ÆÆ Distribution systems cable
Version Fiber qty
± 5% [mm] tension ± 5% [N] [N/10cm]
ÆÆ For patchcords and pigtails
1F 1 0.6 4 ÆÆ Terminals connections
200
1F 1 0.9 5

Features
Available outer jacket colors
ÆÆ Buffer made of LS0H with low coefficient
of friction
ÆÆ 250 µm fiber
ÆÆ Variants with different stripability

SM G.652D SM G.657 MM 62.5/125 OM1 MM 50/125 OM2 MM 50/125 OM3 MM 50/125 OM4
Yellow RAL 1021 A1 / A2 / A3 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet
White RAL 9010 RGB 196, 97, 140 Operating temperature
Stripping
+100
Stripping - length +70°C
Version Fiber qty Stripping
in one piece [cm]
+55°C
1F 1
temperature [°C]

TB00 / TB05 / TB10 3-5 / 20-40 / 100-150


INSTALLATION

1F 1
OPERATION

TRANSPORT

-5°C
Color codes -10°C

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1-12 1 2 3 4 5 6 7 8 9 10 11 12 -40°C

Fiber -100

Buffer

Color red green blue yellow white grey brown violet aqua black orange pink
250/600/900 µm

18 | fiber optic cables 2017


datacom simplex smx cable Simplex SMX 1.2 - 2.8 mm

1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3
3. Central tight buffer tube
600/900 μm with colored
fiber 250 µm
TRUE
COLORS

Flexible Easy to Semi-tight Easy-strip Bendsafe


terminate

Configuration

smx Applications
Max. installation ÆÆ Distribution systems cable
Ø nominal Crush
Version Fiber qty tension
± 5% [mm] [N/10 cm] ÆÆ For patchcords and pigtails
(ε=0.5 %) [N]
ÆÆ Terminals connection
1F 1 1.2 50 200
1F 1 1.6 100 300
1F 1 1.8 150 400
1F 1 2.0 200 500 Features
1F 1 2.8 300 800
ÆÆ LS0H with low coefficient of friction
ÆÆ Aramid yarns
Jacket colors ÆÆ Central tight buffer tube 600/900 µm
ÆÆ 250 µm colored fiber
Standard

Low-radius bending resistance SM


[ mm ]

Yellow RAL 1021 White RAL 9010 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet
RGB 196, 97, 140

30 G.652

Color codes G.657A1


G.657A2/B2
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers 10
7.5 5 G.657B3
2.5 G.657B3 Plus
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Fiber
Operating temperature
Buffer
+100
Color red green blue yellow white grey brown violet aqua black orange pink
250/600/900 µm +70°C

+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-10°C

-40°C

-100

fiber optic cables 2017 | 19


DATACOM
CABLES TRUE
COLORS
Selection of tubes and cables colors
Other colors available on demand

orange green grey brown

red violet yellow pink

black aqua

20 | fiber optic cables 2017


datacom DC-PRIM-14 DC-PRIM-14

1
Cable structure
2
1. LS0H outer jacket
2. Aramid yarns
3. 250 µm optical fibers 3

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-PRIM-14 Applications

No. of fibers 1-2 ÆÆ Optical cable with aramid yarns reinforcement

Outer diameter [mm] (±5%) 1.4 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 100
ÆÆ LAN and FTTX networks
Perm tensile load [N] 50
ÆÆ Distribution network
Weight [kg/km] (±10%) 2 ÆÆ Inside house OLT connection
Min bending radius [mm] 20 ÆÆ Data Center connections cable

Crush [N/10 cm] 50 (reversible)

Outer jacket color options:


Features

ÆÆ Aramid strength element


ÆÆ 250 µm optical fibers (12-24)
ÆÆ LS0H outer jacket
Ivory Yellow White Blue Orange Green Aqua Violet
RAL 1015 RAL 1021 RAL 9010 RAL 5015 RAL 2003 RAL 6018 RAL 6027 RGB 196, 97, 140

Available colors Operating temperature

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers +100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
+55°C
Fiber
temperature [°C]

INSTALATION

OPERTATION

TRANSPORT

Color red green blue yellow white grey brown violet aqua black orange pink

-5°C
-10°C
-20°C

-100

fiber optic cables 2017 | 21


datacom DC-PRIM-20 DC-PRIM 2.0

1
Cable structure
2
1. LSOH outer jacket
2. High modulus aramid strength yarns
3. 250 μm optical fibers 3

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-PRIM-20 Applications

No. of fibers 1-2 ÆÆ Optical cable with aramid yarns reinforcement

Outer diameter [mm] (±5%) 2.0 ÆÆ For customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 170
ÆÆ LAN and FTTX networks
Perm tensile load [N] 75
ÆÆ Distribution network,
Weight [kg/km] (±10%) 3 ÆÆ Inside house OLT connection
Min bending radius [mm] 30 ÆÆ Data center connections cable

Crush [N/10 cm] 100 (reversible)

Outer jacket color options:


Features

ÆÆ Aramid yarns as strain relief


ÆÆ 250μm optical fibers (1-2 pcs)
ÆÆ Outer jacket (LSOH)
Ivory Yellow White Blue Orange Green Aqua Violet ÆÆ Available in different outer jacket colors
RAL 1015 RAL 1021 RAL 9010 RAL 5015 RAL 2003 RAL 6018 RAL 6027 RGB 196, 97, 140
ÆÆ Available for G.657A1, G.657A2, OM3, OM4 fiber
types

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Fiber +70°C

Color red green blue yellow white grey brown violet aqua black orange pink +55°C
temperature [°C]

INSTALATION

OPERTATION

TRANSPORT

-5°C
-10°C
-20°C

-100

22 | fiber optic cables 2017


datacom DC-PRIM DC-PRIM

1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3. 250 µm optical fibers 3

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-PRIM Applications

No. of fibers 12 24 ÆÆ Optical cable with aramid yarns reinforcement

Outer diameter [mm] (±5%) 3.0 3.5 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 350 350
ÆÆ LAN and FTTX networks
Weight [kg/km] (±10%) 8 9
ÆÆ Distribution network
Crush [N/10 cm] 350 ÆÆ Inside house OLT connection
Min. bend radius [mm] 45 (depends on fiber type) 60 (depends on fiber type) ÆÆ Data Center connections cable

Outer jacket color options:

Features

ÆÆ Aramid strength element


ÆÆ 250 µm optical fibers (12-24)
Ivory Yellow White Blue Orange Green Aqua Violet
RAL 1015 RAL 1021 RAL 9010 RAL 5015 RAL 2003 RAL 6018 RAL 6027 RGB 196, 97, 140 ÆÆ LS0H outer jacket

Available colors Operating temperature


D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers +100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C

+55°C
Fiber
temperature [°C]

INSTALLATION

OPERATION

Color red green blue yellow white grey brown violet aqua black orange pink
TRANSPORT

13-24 13 14 15 16 17 18 19 20 21 22 23 24
-5°C
Fiber -10°C

Code
-40°C
Color* red green blue yellow white grey brown violet brown natural orange pink

*Fiber with black mark to identify fibers 13-24 -100

fiber optic cables 2017 | 23


datacom DC-DRIM DC-DRIM

1 1
Cable structure
2
1. LS0H outer jacket
2
3
2. Aramid yarns
3
3. LS0H inner jacket
4. Aramid yarns 5
5. 250 µm optical fibers 4

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-DRIM Applications

No. of fibers 12 24 ÆÆ Optical cable with aramid yarns reinforcement

Outer diameter [mm] (±5%) 4.5 5.0 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 600 600
ÆÆ LAN and FTTX networks
Weight [kg/km] (±10%) 8 9
ÆÆ Distribution network
Crush [N/10cm] 300 ÆÆ Inside house OLT connection
Min. bend radius [mm] 65 (depends on fiber type) 75 (depends on fiber type) ÆÆ Data Center connections cable

Outer jacket color options:

Features

ÆÆ Aramid strength element in two layers


ÆÆ 250 µm optical fibers (12-24)
Ivory Yellow White Blue Orange Green Aqua Violet
RAL 1015 RAL 1021 RAL 9010 RAL 5015 RAL 2003 RAL 6018 RAL 6027 RGB 196, 97, 140 ÆÆ LS0H double jacket

Available colors
Operating temperature
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
+100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C

Fiber +55°C
temperature [°C]

Color red green blue yellow white grey brown violet aqua black orange pink
INSTALLATION

OPERATION

TRANSPORT

13-24 13 14 15 16 17 18 19 20 21 22 23 24
-5°C
Fiber
-10°C

Code

Color* red green blue yellow white grey brown violet brown natural orange pink -40°C

*Fiber with black mark to identify fibers 13-24 -100

24 | fiber optic cables 2017


datacom duplex zip cables Duplex Zip Cables 1.6 - 2.8 mm

Cable structure 1
1. LS0H outer jacket
2. Aramid yarns 2
3. Central tight buffer Tube 3
600/900 µm with colored
fibers 250 µm
TRUE
COLORS

LS0H Bendsafe Easy to Easy-strip Semi-tight


terminate

Configuration

ZIP Applications
Dimensions Max. installation ÆÆ Distribution systems cable
Crush
Version Fiber qty nominal tension
[N/10 cm] ÆÆ Patchcords and pigtails
± 5% [mm] (ε=0.5 %) [N]
ÆÆ Terminals connection
2F 2 1.6 x 3.3 200 500
2F 2 1.8 x 3.7 300 500
2F 2 2.0 x 4.1 400 500
2F 2 2.8 x 5.7 600 1000 Structure and composition

Jacket colors ÆÆ LS0H with low coefficient of friction


ÆÆ Aramid yarns
Standard ÆÆ 250 µm colored fibers

SM low-radius bending resistance


SM G.652D SM G.657 MM 62,5/125 OM1 MM 50/125 OM2 [ mm ]
Yellow RAL 1021 A1 / A2 / A3 Blue RAL 5015 Orange RAL 2003
White RAL 9010

30 G.652

G.657A1
MM 50/125 OM3 MM 50/125 OM4 G.657A2/B2
Violet 10
Aqua RAL 6027 7.5 5 G.657B3
RGB 196, 97, 140 2.5 G.657B3 Plus

Operating temperature

+100
+70°C

+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-10°C

-40°C

-100

fiber optic cables 2017 | 25


datacom Dc-t40 DC-T40

Cable structure
1
1. FRLSOH outer jacket
2. Fibreglass yarns
3. Colored fibers 250 μm 3

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-T40 Applications

Nominal Max. tensile load ÆÆ Drop cable for FTTH networks


Fibers Ø [N]
Total weight Crush ÆÆ Optical access cable with glass yarns
Version Fibers per ± 5%
elements ±5% [N/10 cm] reinforcement
module [mm] allowed static
[kg/km]
ÆÆ Fully dielectric cable
1-4F 1-4 1-4 1 4.2 17 150 50 1100 ÆÆ Last mile connection

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Fibreglass yarn as stain relief elements
Code ÆÆ Optical fiber
ÆÆ Flame retardant LSOH outer sheath
Color red green blue yellow white grey brown violet aqua black orange pink

13-24 13 14 15 16 17 18 19 20 21 22 23 24
Operating temperature
Fiber
+100
Code

Color* red green blue yellow white grey brown violet brown natural orange pink +50°C
temperature [°C]

+30°C
*Fiber with black mark to identify fibers 13-24
OPERTATION

TRANSPORT
INSTALATION

0°C

-25°C

-100

26 | fiber optic cables 2017


datacom LDC LDC

1 2 3
Cable structure
1. Outer jacket LS0H UV stabilized
2. Tight tubes 900 µm (LS0H)
with colored fibers 250 µm
3. Aramid yarns

TRUE
COLORS

LS0H Bendsafe Easy to Easy-strip Semi-tight Datacenter


terminate

Configuration

LDC Applications
Nominal Max. tensile load [N] ÆÆ Indoor/outdoor installations
Tight buffers Ø Crush
Version weight LS0H
[pcs] ± 5% [mm] installation operation [N/10 cm] ÆÆ Distribution networks in multifamily buildings
± 5% [kg/km]
ÆÆ FTTD Connections
2F 2 4.5 21
ÆÆ Distribution systems
4F 4 5.0 26 ÆÆ Fully dielectric
500 125
6F 6 5.5 30 ÆÆ LAN and FTTX network
8F 8 5.5 35 ÆÆ ODF connection
500 ÆÆ Datacenter distribution
10F 10 6.5 40
12F 12 6.5 45 700 175
16F 16 7.0 50
24F 24 8.0 65 1000 250 Features
Other fiber counts available on demand ÆÆ Compact design
ÆÆ Lightweight
Jacket colors ÆÆ Flexible
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers ÆÆ Easy to strip
ÆÆ Fully dielectric
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Reduced diameter
Fiber ÆÆ Direct connectorization

Buffer

Color Operating temperature


250/600/900 red green blue yellow white grey brown violet aqua black orange pink
µm +100
13-24 13 14 15 16 17 18 19 20 21 22 23 24 +70°C

Fiber +55°C
temperature [°C]

INSTALLATION

OPERATION

Code
TRANSPORT

Color red green blue yellow white grey brown violet aqua natural orange pink
250 µm -5°C
Color* dark -10°C
red green blue yellow white grey brown violet brown orange pink
600/900 µm green

*Buffer with black mark to identifiy fibers 13-24


-40°C

-100

fiber optic cables 2017 | 27


datacom LBR LBR

1 1
Cable structure
2
1. Outer jacket LS0H fibers 3
2
3
UV stabilized 3. Aramid yarns
2. Subcables 1.8 mm 4. Central FRP strength
with tight tubes member
4
900 µm (LS0H) with 5. Ripcord
250 µm colored

TRUE
5
COLORS

LS0H Bendsafe Easy to Easy-strip Semi-tight Datacenter


terminate
Configuration

LBR Applications
Ø Nominal weight Max. tensile load [N] ÆÆ Indoor/outdoor installations
Crush
Version Fiber qty ± 5% LS0H ± 5%
installation operation [N/10 cm] ÆÆ Distribution networks in multifamily buildings
[mm] [kg/km]
ÆÆ FTTD Connections
4F 4 6.5 48 750 250
ÆÆ Distribution systems
6F 6 7.5 63 1200 400 ÆÆ Fully dielectric
8F 8 8.7 85 1500 500 ÆÆ LAN and FTTX network
12F 12 10.9 131 1500 500 2000 ÆÆ ODF connection
ÆÆ Datacenter distribution
16F 16 11.3 119 1700 550
18F 18 11.3 131 1700 550
24F 24 13.0 179 2000 660
Features

Standard jacket colors: ÆÆ Simplex sub cable up to 24 fibers


ÆÆ Fully dielectric cable
ÆÆ Aramid yarns as tensile elements
ÆÆ UV Resistant and LS0H flame retardant outer
jacket

PE Black RAL9005 LSOH Grey RAL7022 LSOH Light Grey Operating temper ature
RAL7037
+100
+70°C
Outer jacket color options:
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C

-20°C
SM G.652D SM G657A1, A2, A3 MM 50/125 OM2 MM 50/125 OM3 MM 50/125 OM4
RAL 1021 RAL 9010 RAL 2003 RAL6027 RAL4003 -40°C

-100

28 | fiber optic cables 2017


datacom exo-FU cables EXO-FU Cables Loose tube

Cable structure 1

1. LS0H sheath
2. Glass yarns 2
3. Loose tube (PBT)
4. Optical fibers
3
5. Thixotropic filling compound
6. Ripcord 4

5
Datacom Compact LS0H Basic Rodent
design Protection
Configuration 6

Exo-FU
Ø ± 5%
Nominal weight Max. tensile load [N] Crush
Applications
Version Fiber qty LS0H ± 5%
[mm] installation operation [N/10 cm]
[kg/km] ÆÆ Fully dielectric cable
1T x 2-12F 2-12 6.8 48 ÆÆ Basic rodent protection
1100 550 1600
(ε=0.4%) (ε=0.25%) ÆÆ LAN and FTTX networks
1T x 14-24F 14-24 6.8 49
ÆÆ Distribution network
ÆÆ ODF connections
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Features
Code
ÆÆ Fiberglass strength element
Color red green blue yellow white grey brown violet aqua black orange pink ÆÆ Optical fibers
13-24 13 14 15 16 17 18 19 20 21 22 23 24 ÆÆ Loose tube with filling compound
ÆÆ Loose tube (PBT)
Fiber
ÆÆ Fiberglass as water absorbent and strain relief
element
Code
ÆÆ LS0H outer jacket
Color* red green blue yellow white grey brown violet brown natural orange pink

*Fiber with black mark to identify fibers 13-24


Operating temperature

+100
Jacket colors Fiber identification +70°C
+60°C
Standard +50°C
temperature [°C]

OPERATION

TRANSPORT

13
INSTALLATION

24 14
1
2
23 15

22 16

21 17
-10°C
20
19
18
-20°C
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-40°C
Optional
-100

SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL6027 RAL4003

fiber optic cables 2017 | 29


datacom exo-FI cables EXO-FI Cables Loose tube

Cable structure 1

1. LS0H sheath
2. Glass yarns 2
3. Loose tube (PBT)
4. Optical fibers
3
5. Thixotropic filling compound
6. Ripcord 4

5
Datacom Compact LS0H Basic Rodent
design Protection
6

Configuration

Exo-FU Applications
Nominal weight Max. tensile load [N] ÆÆ Fully dielectric cable
Ø ± 5% Crush
Version Fiber qty LS0H ± 5%
[mm] installation operation [N/10 cm] ÆÆ Basic rodent protection
[kg/km]
ÆÆ LAN and FTTX networks
1T x 2-12F 2-12 7.1 54
2000 1000 1600 ÆÆ Distribution network
(ε=0.4%) (ε=0.25%)
1T x 14-24F 14-24 7.1 55 ÆÆ ODF connections

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Central loose tubes (PBT Ø 3.0mm) with thixo-
Code tropic filing compound
ÆÆ Glass yarns as strain relief and water absorbent
Color red green blue yellow white grey brown violet aqua black orange pink
ÆÆ Polyester ripcord
13-24 13 14 15 16 17 18 19 20 21 22 23 24 ÆÆ UV stabilized LSOH sheath (different colors
available)
Code

Color red green blue yellow white grey brown violet aqua natural orange pink
Operating temperature
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
+100
+70°C
Jacket colors Fiber identification +60°C
+50°C
temperature [°C]

Standard
INSTALLATION

OPERATION

TRANSPORT

13
24 14
1
2
23 15

-10°C
22 16
-20°C
21 17

20 18
19

PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 -40°C

-100
Optional

SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL6027 RAL4003

30 | fiber optic cables 2017


datacom exo-GU cables EXO-GU Cables Loose tube

Cable structure 1

1. LS0H outer jacket 3


4
2
2. Central loose tube (PBT)
with colored fibers in filling
compound
3. Optical fibers 5
4. Fiberglass yarns
5. Ripcord

Datacom Compact LS0H Basic Rodent


design Protection
Configuration

Exo-GU
Fibers Ø ± 5%
Nominal weight Max. tensile load [N] Crush
Applications
Version Fiber qty LS0H ± 5%
per tube [mm] installation operation [N/10 cm]
[kg/km] ÆÆ Fully dielectric cable
1T x 2F 2 2 5.8 34 ÆÆ Basic rodent protection
ÆÆ LAN and FTTX networks
1T x 4F 4 4 5.8 34
ÆÆ Distribution network
1T x 6F 6 6 5.8 35
1200 ÆÆ ODF connections
1T x 8F 8 8 5.8 35 (ε=0,33%)
400 1500
1T x 12F 12 12 5.8 35 1500
(ε=0,5%)
1T x 16F 16 16 5.8 35
1T x 18F 18 18 5.8 36 Features
1T x 24F 24 24 5.8 36 ÆÆ Central loose tube (PBT) with filling compound
ÆÆ Optical fibers
ÆÆ Fiberglass as water absorbent and strain relief
Available colors element
ÆÆ LS0H outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code Operating temperature
Color red green blue yellow white grey brown violet aqua black orange pink +100
13-24 13 14 15 16 17 18 19 20 21 22 23 24 +70°C

Code +55°C
temperature [°C]

Color red green blue yellow white grey brown violet aqua natural orange pink
INSTALLATION

OPERATION

TRANSPORT

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
-5°C

Jacket colors Fiber identification -20°C

Standard
24
13
14 -100
1
2
23 15

22 16

21 17

20 18
19

PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

Optional

SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003

fiber optic cables 2017 | 31


datacom exo-G0 cables EXO-G0 Cables Loose

Cable structure 1

1. LS0H outer jacket 4


2 3
2. Central loose tube (PBT)
with colored fibers in filling
compound
3. Optical fibers 5
4. Fiberglass yarns
5. Ripcord

Datacom Compact LS0H Basic Rodent


design Protection
Configuration

Exo-G0
Nominal Max. tensile load [N] Applications
Fibers
Fiber Ø ± 5% weight LS0H Crush
Version per ÆÆ Fully dielectric cable
qty [mm] ± 5% installation operation [N/10 cm]
tube
[kg/km] ÆÆ Basic rodent protection
ÆÆ LAN and FTTX networks
1T x 2F 2 2 5.9 37
ÆÆ Distribution network
1T x 4F 4 4 5.9 37
ÆÆ ODF connections
1T x 6F 6 6 5.9 37
1500
1T x 8F 8 8 5.9 37 (ε=0,33%)
500 1500
1T x 12F 12 12 5.9 38 2200
(ε=0,5%)
1T x 16F 16 16 5.9 38 Features

1T x 18F 18 18 5.9 38 ÆÆ Central loose tube (PBT) with filling compound


1T x 24F 24 24 5.9 40 ÆÆ Optical fibers
ÆÆ Fiberglass as water absorbent and strain relief
Available colors element
ÆÆ LS0H outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code Operating temperature
Color red green blue yellow white grey brown violet aqua black orange pink
+100
+70°C
13-24 13 14 15 16 17 18 19 20 21 22 23 24
+55°C
Code
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

Color red green blue yellow white grey brown violet aqua natural orange pink

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm; -5°C

-20°C
Jacket colors Fiber identification

Standard
24
13
14
-100
1
2
23 15

22 16

21 17

20 18
19

PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

Optional

SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003

32 | fiber optic cables 2017


datacom exo-GI cables EXO-GI Cables Loose tube

Cable structure 1

1. LS0H outer jacket 3


4
2
2. Central loose tube (PBT)
with colored fibers in filling
compound
3. Optical fibers 5
4. Fiberglass yarns
5. Ripcord

Datacom Compact LS0H Basic Rodent


design Protection

Configuration

Exo-GI Applications

Nominal Max. tensile load ÆÆ Fully dielectric cable


Ø ± 5% weight LS0H [N] Crush
Version Fiber qty Fibers per tube ÆÆ Basic rodent protection
[mm] ± 5% installa- opera- [N/10 cm]
[kg/km] ÆÆ LAN and FTTX networks
tion tion
ÆÆ Distribution network
1T x 2F 2 2 6.1 38
ÆÆ ODF connections
1T x 4F 4 4 6.1 38
1T x 6F 6 6 6.1 39
1800
1T x 8F 8 8 6.1 40 (ε=0,33%)
600 1500
1T x 12F 12 12 6.1 40 2700 Features
(ε=0,5%)
1T x 16F 16 16 6.1 41 ÆÆ Central loose tube (PBT) with filling compound
1T x 18F 18 18 6.1 42 ÆÆ Optical fibers

1T x 24F 24 24 6.1 42 ÆÆ Fiberglass as water absorbent and strain relief


element
ÆÆ LS0H outer jacket
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code +100
+70°C
Color red green blue yellow white grey brown violet aqua black orange pink
+55°C
13-24 13 14 15 16 17 18 19 20 21 22 23 24
temperature [°C]

Code
INSTALLATION

OPERATION

TRANSPORT

Color red green blue yellow white grey brown violet aqua natural orange pink
-5°C
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
-20°C

Jacket colors Fiber identification

Standard -100
13
24 14
1
2
23 15

22 16

21 17

20 18
19

PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037

SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003 fiber optic cables 2017 | 33
datacom bdc-MSA DATACOM BDC-MSA

Cable structure
1
1. LS0H outer jacket 6. Loose tubes (PBT) 2
2. Water-blocking with colored fibers
fiberglass yarns in filling gel 4
3. Water blocking yarns 7. Fillers
4. PET tape 8. Ripcord 5
3
5. Central strength
6
member (FRP) 7

Datacom ETR Compact LS0H Basic Rodent Datacenter


design Protection
Configuration

BDC-msa Applications

Nominal Max. tensile ÆÆ Fully dielectric cable


Nominal load [N]
Fibers Total Ø weight ÆÆ Basic rodent protection
Active weight PE Crush
Version Fibers per ele- ± 5% LS0H
tubes ±5% instal- oper- [N/10 cm] ÆÆ LAN and FTTX networks
tube ments [mm] ±5%
[kg/km] lation ation ÆÆ Distribution network
[kg/km]
ÆÆ ODF connections
1T x 12F 12 12 6 1 8.2 50 65 1500 550
2T x 6F 12 6 6 2 8.2 50 65 1550 780
2T x 12F 24 12 6 2 8.2 51 65 1500 550
4T x 6F 24 6 6 4 8.2 51 66 1550 780 Features
3T x 12F 36 12 6 3 8.2 52 67 1500 550 ÆÆ FRP strength and anti-buckling element
6T x 6F 36 6 6 6 8.2 53 68 1550 780 1500 ÆÆ Optical fibers

4T x 12F 48 12 6 4 8.2 53 68 1500 550 ÆÆ Loose tube with filling compound (PBT Ø 1.8 mm)
ÆÆ Dry yarns to prevent moisture into the cable
5T x 12F 60 12 6 5 8.2 54 69 1500 550
ÆÆ Fiberglass as water absorbent and strain relief
6T x 12F 72 12 6 6 8.2 54 69 1500 550 element
8T x 12F 96 12 8 8 9.3 71 86 1620 750 ÆÆ UV stabilized LS0H jacket

12T x 12F 144 12 12 12 11.5 104 126 1620 850

Operating temperature
Available colors
+100
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers +70°C
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +55°C
temperature [°C]

INSTALLATION

Code
OPERATION

TRANSPORT

Color red green blue yellow white grey brown violet aqua black orange pink
-5°C

D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Tubes -20°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
-40°C
Code
-100
Color red green blue yellow white grey brown violet aqua black orange pink
*In case of lower fiber count some tubes can be replaced by fillers.

34 | fiber optic cables 2017


FTTH
Cables
VC-D20/VC-D30
VC-D40/VC-DCY
SOLID CONNECTION TO YOUR PROVIDER

EASY TO
BEND TERMINATE
RESISTANCE
LSOH
SAFE COVER

SMALL SAFE
DIMENSIONS DAILY USE
ftth VC-d20 FTTH VC-D20

1
2
Cable structure 3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-d20 Applications

No. of fibers 1F 900 µm ÆÆ Optical cable with aramid yarns reinforcement

Outer diam [mm] 2.0 ÆÆ Customer connection


ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 75/200
ÆÆ Last mile connection
Weight [kg/km] 7
ÆÆ LAN and FTTX networks
Min. bend radius [mm] 10-60 mm* ÆÆ Distribution network
Crush [N/10 cm] 300 ÆÆ ODF connections
ÆÆ Inside house OLT connection
*Depends on fiber type

Bend radius/maximum attenuation


Features
G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus
Max. attenuation for wavelength

60
ÆÆ Aramid strength element
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40 ÆÆ Optical 900 µm semi tight tube


0.03dB

0.03dB

0.03dB

0.03dB
Bend radius [mm]

30 ÆÆ LS0H outer jacket

15

10 Operating temperature
7,5
+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

fiber optic cables 2017 | 37


ftth VC-d30 FTTH VC-D30

1
2
Cable structure 3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-d30 Applications

No. of fibers 1F 900 µm ÆÆ Optical cable with aramid yarns reinforcement

Outer diam [mm] 3.0 ÆÆ Customer connection


ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 60/170
ÆÆ Last mile connection
Weight [kg/km] 8
ÆÆ LAN and FTTX networks
Min. bend radius [mm] 10-60 mm* ÆÆ Distribution network
Crush [N/10 cm] 500 ÆÆ ODF connections
ÆÆ Inside house OLT connection
*Depends on fiber type

Bend radius/maximum attenuation


Features
G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus
Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

ÆÆ Aramid strength element


1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40 ÆÆ Optical 900 µm semi tight tube


0.03dB

0.03dB

0.03dB

0.03dB
Bend radius [mm]

30 ÆÆ LS0H outer jacket


15

10
Operating temperature
7,5

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

38 | fiber optic cables 2017


ftth VC-d40 FTTH VC-D40

1
Cable structure
2
1. LS0H outer jacket 3
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration
Applications
VC-d40
No. of fibers 1-2F 900 µm ÆÆ Optical cable with aramid yarns reinforcement
ÆÆ Customer connection
Outer diam [mm] 4.0
ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 150/400 ÆÆ Last mile connection
Weight [kg/km] 15 ÆÆ LAN and FTTX networks
Min. bend radius [mm] 10-60 mm* ÆÆ Distribution network

Crush [N/10 cm] 1000 ÆÆ ODF connections


ÆÆ Inside house OLT connection
*Depends on fiber type

Bend radius/maximum attenuation

G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus


Features
Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

ÆÆ Aramid strength element


1550 nm 1625nm/both [dB]

40
ÆÆ Optical 900 µm semi tight tube
0.03dB

0.03dB

0.03dB

0.03dB
Bend radius [mm]

30 ÆÆ LS0H outer jacket


15

10
Operating temperature
7,5

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

fiber optic cables 2017 | 39


ftth VC-dcy FTTH VC-DCY

Cable structure
1. LS0H outer jacket 3 2 1
(white/ivory/black)
2. FRP rod
3. 250 µm optical fibers

Last mile LS0H Flexible Bendsafe Easy to FTTH Hi-crush


connection terminate
outdoor

Configuration

VC-dCY Applications

No. of fibers 1-4F 900 µm ÆÆ FTTH drop cable reinforced with FRP rods

Outer diam [mm] 2.0x3.1 ±0.2 ÆÆ Customer connection


ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 50/100
ÆÆ Last mile connection
Weight [kg/km] 8.3
ÆÆ LAN and FTTX networks
Min. bend radius [mm] 15-40 mm* ÆÆ Distribution network
Crush [N/10 cm] 1000 ÆÆ ODF connections
ÆÆ Inside house OLT connection
*Depends on fiber type

Bend radius/maximum attenuation

G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus


Features
Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40 ÆÆ FRP rods
0.03dB

0.03dB

0.03dB

0.03dB
Bend radius [mm]

ÆÆ 250 µm optical fibers


30
ÆÆ LS0H outer jacket
15

10

7,5 Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

-30°C

-100

40 | fiber optic cables 2017


ftth VC-d30 resibend ® FTTH VC-D30 RESIBEND®

1
Cable structure 2
3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Resibend®

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-d30 resibend® Applications

No. of fibers 1F 900 µm ÆÆ Optical cable with aramid yarns reinforcement

Outer diam [mm] 3.0 ÆÆ For customer connection


ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 60/170
ÆÆ Last mile connection
Weight [kg/km] 8
ÆÆ LAN and FTTX networks
Min. bend radius [mm] 5 ÆÆ Distribution network
Crush [N/10 cm] 500 ÆÆ ODF connections
ÆÆ Inside house OLT connection
Bend radius/maximum attenuation

G.657B3
Max. change in attenuation [dB] Features
Fiber bending radius [mm]
1550 nm 1625 nm
ÆÆ Aramid yarns as strain relief
5 0.10 0.25 ÆÆ Optical fiber in 900 µm semi tight buffer
7.5 0.05 0.15 ÆÆ LS0H outer jacket (various colors available)
ÆÆ G.657B3 optical fibers
10 0.03 0.10

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

42 | fiber optic cables 2017


ftth VC-d30 resibend plus® FTTH VC-D30 RESIBEND PLUS®

1
Cable structure 2
3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Resibend Plus®

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-d30 resibend plus® Applications

No. of fibers 1F 900 µm ÆÆ Optical cable with aramid yarns reinforcement

Outer diam [mm] 3.0 ÆÆ For customer connection


ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 60/170
ÆÆ Last mile connection
Weight [kg/km] 8
ÆÆ LAN and FTTX networks
Min. bend radius [mm] 2.5 ÆÆ Distribution network
Crush [N/10 cm] 500 ÆÆ ODF connections
ÆÆ Inside house OLT connection
Bend radius/maximum attenuation

G.657B3+
Max. change in attenuation [dB] Features
Fiber bending radius [mm]
1550 nm 1625 nm
ÆÆ Aramid yarns as strain relief
2.5 0.20 0.30 ÆÆ Optical fiber in 900 µm semi tight buffer
5 0.10 0.20 ÆÆ LS0H outer jacket (various colors available)
ÆÆ G.657B3+ optical fibers

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

fiber optic cables 2017 | 43


ftth VC-d20 Easy Section Module ® FTTH VC-D20 Easy Section Module®

1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-D20 Easy Section Module® Applications

Nominal Max. tension ÆÆ Optical cable with aramid yarns reinforcement


Fibers Ø [N]
Total Active weight Crush ÆÆ For customer connection
Version Fibers per ± 5%
elements modules ±5% [N/10 cm]
module [mm] allowed static ÆÆ Fully dielectric cable
[kg/km]
ÆÆ Last mile connection
2F 2 2 1 1 2.0 7
200 75 1000 ÆÆ LAN and FTTX networks
4F 4 4 1 1 2.0 7 ÆÆ Distribution network
ÆÆ ODF connections
Bend radius/maximum attenuation ÆÆ Inside house OLT connection

G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus


Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40
0.03dB

0.03dB

0.03dB

0.03dB

Features
Bend radius [mm]

30

15
ÆÆ Aramid strength element
ÆÆ Optical fibers (up to 4 pcs) inside 900 µm
10
Easy Section Module®
7,5 ÆÆ LS0H outer jacket

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

fiber optic cables 2017 | 45


ftth VC-d30 Easy Section Module ® FTTH VC-D30 Easy Section Module®

1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®

Last mile
Last mile connection
LS0H outdoor
Flexible Bendsafe Easy to FTTH Bendsafe
connection terminate
outdoor

Configuration

VC-D30 Easy Section Module® Applications

Nominal Max. tension ÆÆ Optical cable with aramid yarns reinforcement


Fibers Ø [N]
Total Active weight Crush ÆÆ For customer connection
Version Fibers per ± 5%
elements modules ±5% [N/10 cm]
module [mm] allowed static ÆÆ Fully dielectric cable
[kg/km]
ÆÆ Last mile connection
2F 2 2 1 1 3.1 9
170 60 1000 ÆÆ LAN and FTTX networks
4F 4 4 1 1 3.1 9 ÆÆ Distribution network
ÆÆ ODF connections
Bend radius/maximum attenuation ÆÆ Inside house OLT connection

G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus


Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40
0.03dB

0.03dB

0.03dB

0.03dB

Features
Bend radius [mm]

30

15 ÆÆ Aramid strength element


ÆÆ Optical fibers (up to 4 pcs) inside 900 µm
10
Easy Section Module®
7,5
ÆÆ LS0H outer jacket

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

46 | fiber optic cables 2017


ftth VC-d40 Easy Section Module ® FTTH VC-D40 Easy Section Module®

1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®

Last mile LS0H Flexible Bendsafe Easy to FTTH


connection terminate
outdoor

Configuration

VC-D40 Easy Section Module® Applications

Nominal Max. tension ÆÆ Optical cable with aramid yarns reinforcement


Fibers Ø [N]
Total Active weight Crush ÆÆ For customer connection
Version Fibers per ± 5%
elements modules ±5% [N/10 cm]
module [mm] allowed static ÆÆ Fully dielectric cable
[kg/km]
ÆÆ Last mile connection
2F 2 2 1 1 4.1 15
420 150 1000 ÆÆ LAN and FTTX networks
4F 4 4 1 1 4.1 15 ÆÆ Distribution network
ÆÆ ODF connections
Bend radius/maximum attenuation ÆÆ Inside house OLT connection

G.652D G.652D LL G.657A1 G.657A2 G.657B3 G.657B3 Plus


Max. attenuation for wavelength

60
0.15dB 0.05dB

0.30dB 0.10dB
1.00dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB

0.30dB 0.20dB
0.50dB 0.20dB

1.50dB 0.50dB

0.10dB 0.03dB

0.20dB 0.10dB
1.00dB 0.25dB

1.00dB 0.25dB

1550 nm 1625nm/both [dB]

40
Features
0.03dB

0.03dB

0.03dB

0.03dB
Bend radius [mm]

30
ÆÆ Aramid strength element
15
ÆÆ Optical fibers (up to 4 pcs) inside 900 µm
10 Easy Section Module®
7,5 ÆÆ LS0H outer jacket

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

fiber optic cables 2017 | 47


ftth DC-PRIM DC-PRIM

Cable structure 1
1. LS0H outer jacket 2
2. Aramid yarns
3. 250 µm optical fibers 3

TRUE
COLORS

LS0H Bendsafe Easy to Datacenter


terminate

Configuration

DC-PRIM Applications

No. of fibers 12 24 ÆÆ Optical cable with aramid yarns reinforcement

Outer diameter [mm] 3.0 3.5 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Tensile load perm/inst. [N] 350/150 350/150
ÆÆ LAN and FTTX networks
Weight [kg/km] 8 9
ÆÆ Distribution network
Min. bend radius [mm] 45 (depends on fiber type) 50 (depends on fiber type) ÆÆ Inside house OLT connection
Min. bend radius [mm] 150 ÆÆ Data Center connections cable

Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Aramid strength element
Fiber ÆÆ 250 µm optical fibers (12-24)
Color red green blue yellow white grey brown violet aqua black orange pink ÆÆ LS0H outer jacket

13-24 13 14 15 16 17 18 19 20 21 22 23 24

Fiber Operating temperature

Code +100

Color* red green blue yellow white grey brown violet brown natural orange pink +70°C
+55°C
*Fiber with black mark to identify fibers 13-24
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-5°C
-20°C

-40°C

-100

48 | fiber optic cables 2017


ftth EAC-Ras FTTH EAC-RAs

Cable structure
1. LS0H outer jacket 1
2. Dielectric strength members
3. 900 µm semi tight buffer (LS0H)
2
with colored 250 µm optical fiber

Last mile LS0H Flexible Bendsafe Easy to


Easy to terminate FTTH
connection terminate
outdoor

Configuration

EAC-Ras Applications
Max. ÆÆ Distribution cable
Nominal tensile
Ø ÆÆ For laying in risers
weight load [N] Crush
Version Fibers Buffers ± 5% ÆÆ FTTH feeder
±5% [N/10 cm]
[mm]
[kg/km] ÆÆ Easy access and installation
installation

8F 8 8 8.7 68 400
12F 12 12 8.7 72 400
1000 Features
16F 16 16 12.0 98 600
24F 24 24 12.0 106 600 ÆÆ FRP strength members inside cable jacket
ÆÆ Optical fibers in bundles
Other fiber counts available on demand
ÆÆ 2-24 elements in cable
Available colors ÆÆ LS0H UV resistant outer jacket (ivory by default,
various colors available)
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Operating temperature
Fiber
+100
Buffer
+70°C
Color red blue green yellow violet white orange grey brown black aqua pink +55°C
250 µm
temperature [°C]

INSTALLATION

OPERATION

Color
TRANSPORT

600/900 µm
red blue green yellow violet white orange grey brown black aqua pink

13-24 13 14 15 16 17 18 19 20 21 22 23 24 -5°C
-20°C
Fiber
-40°C
Code

Color red blue green yellow violet white orange grey brown black aqua pink
250 µm -100
Color* dark
red blue green yellow violet white orange grey brown aqua pink
600/900 µm green
Fiber extraction up to 25 m
*Buffer with black mark to identifiy fibers 13-24

Fiber extraction

fiber optic cables 2017 | 49


ftth EAC-RAm
Cable structure
FTTH EAC-RAm

1. LS0H outer jacket


2. Dielectric strength members
3. Easy Section Modules with 250 µm 1
colored fiber

3
Last mile LS0H Flexible Bendsafe Easy to FTTH
connection terminate
outdoor
Configuration
Last mile
connection outdoor
EAC-RAm
Max. tensile load
Nominal [N]
Easy Section Ø ± 5% Crush
Version Fibers weight ±10%
Modules [mm] ε=0.6% Δ α≤ 0.1 dB, [N/10 cm] Applications
[kg/km]
reversible
ÆÆ Distribution cable
2F Easy Section Modules
ÆÆ For laying in risers
12-18 6-9 8,7 69 400
500 ÆÆ FTTH feeder
20-30 10-15 9,5 79 400 ÆÆ Easy access and installation
32-48 16-24 12,0 106 600
4F Easy Section Modules
16-36 4-9 8,7 70 400
Features
40-48 10-12 9,5 78 400 500
ÆÆ FRP strength members inside cable jacket
52-60 13-15 10,5 85 400
ÆÆ Optical fibers in bundles
64-96 16-24 12,0 110 600
ÆÆ 2-24 elements in cable
6F Easy Section Modules ÆÆ LS0H UV resistant outer jacket (ivory by default,
12-24 2-4 8,7 70 400 various color available)

30-72 5-12 10,5 90 400 500


78-96 13-16 12,0 112 600 Operating temperature
102-144 17-24 13,0 130 600
+100
8F Easy Section Modules
+70°C
16-32 2-4 8,7 67 400 500 +55°C
temperature [°C]

40-96 5-12 10,5 89 400


INSTALLATION

OPERATION

TRANSPORT

12F Easy Section Modules


24-48 2-4 8,7 70 400 -5°C
500
60-120 5-8 10,5 90 400 -20°C

108-144 9-12 12,0 115 600 -40°C

F-FTTH (according to DIN VDE 0888 & IEC 60304)


1-12 1 2 3 4 5 6 7 8 9 10 11 12 -100
Fiber

Color 250 µm red blue green yellow violet white orange grey brown black aqua pink
Fiber extraction up to 25 m
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Module

Color red blue green yellow violet white orange grey brown black aqua pink
Fiber extraction
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Module
dark
Color* red blue green yellow violet white orange grey brown aqua pink
green

*Black mark to identify Easy Section Modules 13-24

50 | fiber optic cables 2017


ftth DAC-Burry FTTH DAC-BURRY

Cable structure
2
1. PP/HDPE outer jacket 4 3
2. Aramid yarns
3. Central loose tube (PBT)
with 250 µm colored fibers
in filling gel
4. Dielectric strength members
in the jacket

Direct FTTH Last mile Hi-crush Compact


buried connection design
outdoor

Configuration

DAC-BURRY Applications
Nominal Max. tensile load [N] ÆÆ Optical access cable with aramid yarns reinforce-
Ø
Fibers weight PE Crush ment
Version Fibers ± 5%
per tube ± 5% [N/10 cm]
[mm] installation operation ÆÆ Direct buried design
[kg/km]
ÆÆ Fully dielectric cable
1T x 2F 2 2 6.2 32
ÆÆ Last mile connection
1T x 4F 4 4 6.2 32 ÆÆ High crush resistance (3.5kN)
1Tx 6F 6 6 6.2 32 650 250 3500 ÆÆ Installation into existing ducts or direct buried
1T x 8F 8 8 6.2 32
1T x 12F 12 12 6.2 32

Features
Available colors
ÆÆ Central loose tube (PBT) with filling compound
T-Telecom (according to IEC 60304) - Fibers in tube ÆÆ Up to 12 optical fibers (250 µm)
1-12 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ Embedded FRP strength members
Code
ÆÆ Highly resistant outer jacket made of hard polyole-
fin material, UV resistant
Color red green blue white violet orange grey yellow brown pink black aqua

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

-15°C

-40°C

-100

fiber optic cables 2017 | 51


ftth DAC-Burry-G FTTH DAC-BURRY-G

1
Cable structure
2
1. Outer jacket
4 3
2. Fiberglass yarns
3. Central loose tube (PBT)
with 250 µm colored fibers
in filling gel
4. Embedded strength members (FRP)

Direct FTTH Last mile Hi-crush Compact


buried connection design
outdoor

Configuration

DAC-BURRY-G Applications
Nominal Max. tensile load [N] ÆÆ Optical access cable with glass yarns reinforce-
Ø
Total Fibers weight PE Crush ment
Version ± 5%
fibers per tube ± 5% [N/10 cm]
[mm] installation operation ÆÆ Direct buried design
[kg/km]
ÆÆ Fully dielectric cable
1T x 2-12F 2-12 2-12 6.0 29
450 150 3500 ÆÆ Last mile connection
1T x 14-24F 14-24 14-24 6.5 35 ÆÆ High crush resistance (3.5kN)
ÆÆ Installation into existing ducts or direct buried

Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12 1 2 3 4 5 6 7 8 9 10 11 12 Features

Code ÆÆ Central loose tube (PBT) with filling compound


ÆÆ Up to 24 optical fibers (250 µm)
Color red green blue white violet orange grey yellow brown pink black aqua
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ Embedded FRP strength members
ÆÆ Highly resistant outer jacket made of hard polyole-
fin material, UV resistant

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

-15°C

-40°C

-100

52 | fiber optic cables 2017


ftth vc-t601-PE VC-T601-PE

Cable structure
1 2 3
1. HDPE UV resistant outer jacket
2. Aramid yarns
5
3. Inner LS0H jacket
4. FRP rods
4
5. Module with optical fibers
6. Ripcords
TRUE 6
COLORS

LS0H Bendsafe Easy to Easy-strip Semi-tight Datacenter


terminate

Configuration

VC-t601-PE Applications

Nominal Max. tensile load ÆÆ Drop cable for FTTH networks


Fibers [N]
Total weight Crush ÆÆ Optical access cable with aramid yarns reinforce-
Version Fibers per Ø [mm]
elements ±5% [N/10 cm] ment
module allowed static
[kg/km]
ÆÆ Direct buried construction
1F 1 1 1 max. 6.0 33 1200 300 500 ÆÆ Fully dielectric cable
ÆÆ Last mile connection
Application and cable span characteristics ÆÆ Suitable for aerial, façade installation
Wind load: max 72 km/h
span: 70 m

Features
sag: 0.7 m
ÆÆ Aramid yarns as strength and water absorbent
elements
Ice load: max 5 mm ÆÆ Tight buffer or modules with optical fibers
span: 50 m ÆÆ ITU-T G.657A2 optical fiber(s)
ÆÆ Embedded strength members (FRP)
ÆÆ Highly resistant outer jacket made of HDPE
material
sag: 0.5 m
ÆÆ UV stabilized
ÆÆ Flexible internal LSZH subcable

Operating temperature

+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-15°C
-25°C
-40°C

-100

fiber optic cables 2017 | 53


ftth vc-t60 VC-T60

Cable structure 1 2 3
1. HDPE UV resistant outer jacket
2. Aramid yarns
5
3. Inner LS0H jacket
4. FRP rods 4
5. Module with optical fibers

TRUE
COLORS

LS0H Bendsafe Easy to Easy-strip Semi-tight Datacenter


terminate

Configuration

VC-t60 Applications

Nominal Max. tensile load ÆÆ Drop cable for FTTH networks


Fibers Ø [N]
Total weight Crush ÆÆ Optical access cable with aramid yarns reinforce-
Version Fibers per ± 5%
elements ±5% [N/10 cm] ment
module [mm] allowed static
[kg/km]
ÆÆ Direct buried construction
1-4F 1-4 1-4 1 6.0 30 800 250 2000 ÆÆ Fully dielectric cable
ÆÆ Last mile connection

Application and cable span characteristics


NESC Light
span: 80 m
Features

ÆÆ Aramid yarns as strength and water absorbent


elements
sag: 1.6 m
ÆÆ Easy strip buffer or modules with optical fibers
ÆÆ Embedded strength members (FRP)
NESC Medium
span: 40 m
ÆÆ Highly resistant outer jacket made of HDPE
material
ÆÆ UV stabilized

sag: 0.8 m
Operating temperature

NESC Heavy +100


span: 20 m
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

sag: 0.4 m

-5°C
-20°C

-40°C

-100

54 | fiber optic cables 2017


Microduct
TRENCH
MICROCABLES

OPTIMAL
DIAMETER
HIGH BLOWING
RANGE

HIGH FIBERS
DENSITY

LOW FRICTION
COEFFICIENT
UNIT DESIGN
microduct MK-AX2 MICRODUCT MK-AX2

1
Cable structure
1. Polymeric jacket with low coefficient
of friction
2. 250 µm colored fibers 2

Microduct FTTH Last mile Blowing Flexible Compact Bendsafe


Generation 1 connection installation design
outdoor

Configuration

MetroJET MK-AX2 Applications


Ø Nominal weight ±10% Max. install. Crush ÆÆ Microduct air-blowing application
Version Fibers
± 5% [mm] [kg/km] tension [N] [N/10 cm]
ÆÆ Metro networks
1T x 2F 2 1.1 1.2 ÆÆ Flexible network design
1T x 4F 4 1.1 1.4 ÆÆ Distribution network
1T x 6F 6 1.5 1.6
15 100
1T x 8F 8 1.5 1.8
1T x 10F 10 1.6 2.0 Features
1T x 12F 12 1.6 2.2
ÆÆ Polymeric jacket with low coefficient of friction

Compatibility table ÆÆ Central tube without gel


ÆÆ 250 µm colored fibers
standard microduct Direct burried ducts
Outer Ø Inner Ø MK-AX2 Outer Inner MK-AX2
Version Version
[mm] [mm] 2-4F 6-12F Ø [mm] Ø [mm] 2-4F 6-12F Operating temperature
3/2.1 3 2.1 - 7/3.5 7 3.5
+100
5/3.5 5 3.5 7/3.8 7 3.8
+70°C
7/5.5 7 5.5 7/4 7 4 +55°C
temperature [°C]

10/8 10 8 10/5.5 10 5.5


INSTALLATION

OPERATION

TRANSPORT
12/10 12 10 12/8 12 8 -
14/12 14 12 14/10 14 10 -
-15°C
Fiber qty 2-12 Fiber qty 2-12 -30°C
-40°C
Available colors

-100

fiber optic cables 2017 | 57


microduct MK-LX4 MICRODUCT MK-LX4

1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT) 5. Water blocking yarns
5
with colored fibers in 6. Water blocking yarns
filling gel on strand element
3. Fillers 7. Ripcord 6
4. Central strength
member (FRP)
7
Optimal Low Telecom Blowing Microduct
diameter friction installation Generation 1

Configuration

MetroJET MK-LX4 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Total Ø load [N]
Active weight Crush ÆÆ Metro networks
Version Fibers per ele- Fillers ± 5%
tubes ±10% instal- oper- [N/10 cm]
tube ments [mm] ÆÆ Flexible network design
[kg/km] lation ation
ÆÆ Distribution network
1T x 4F 4 4 6 1 5 4.2 8
2T x 4F 8 4 6 2 4 4.2 8
3T x 4F 12 4 6 3 3 4.2 9
250 150 500
4T x 4F 16 4 6 4 2 4.2 9 Features
5T x 4F 20 4 6 5 1 4.2 10 ÆÆ HDPE, UV stabilized outer jacket with low friction
6T x 4F 24 4 6 6 0 4.2 10 ÆÆ Loose tubes (and fillers), SZ stranded around
the CSM
Other fiber counts available on demand
ÆÆ PBT tubes containing up to 4 optical fibers
Compatibility table ÆÆ Smallest outer diameter for blowing into 5.5 mm
(ID) ducts
standard microduct Direct burried ducts
Outer Ø Inner Ø Outer Inner Ø
Version MK-LX4 Version MK-LX4
[mm] [mm] Ø [mm] [mm]

3/2.1 3 2.1 - 7/3.5 7 3.5 - Operating temperature


5/3.5 5 3.5 - 7/3.8 7 3.8 - +100
7/5.5 7 5.5 7/4 7 4 - +70°C
10/8 10 8 +55°C
10/5.5 10 5.5
temperature [°C]

INSTALLATION

12/10 12 10 12/8 12 8
OPERATION

TRANSPORT

14/12 14 12 - 14/10 14 10
Fiber qty 4-24 Fiber qty 4-24 -15°C

-30°C
-40°C
Available colors
T-Telecom (according to IEC 60304) - Fibers T-Telecom (according to IEC 60304) - Tubes
-100
1-12 1 2 3 4 Tube 1 2 3 4 5 6

Code Code

Color red green blue white Color red green blue white violet orange

*In case of lower fiber count some tubes can be replaced by


fillers.

58 | fiber optic cables 2017


microduct MK-LX5 MICRODUCT MK-LX5

3 1
Cable structure 2
1. Outer sheath: HDPE 4
2. Loose tubes (PBT) with optical
fibers 5
3. Filling compound
4. Central strength member (FRP) 6
5. Water swellable yarns on FRP
6. Water swellable yarns on S-Z
stranded cable core 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LX5 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system application


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per ± 5%
elements tubes ±10% instal- opera-
[N/10 cm]
tube [mm] ÆÆ Flexible network design
[kg/km] lation tion
ÆÆ Distribution network
1-5T x 4F 4-20 4 5 1-5 5.2 21
1-5T x 6F 6-30 6 5 1-5 5.2 21
1-5T x 8F 8-40 8 5 1-5 5.2 21 500 150 1000
1-5T x 10F 10-50 10 5 1-5 5.2 22 Features
1-5T x 12F 12-60 12 5 1-5 5.2 22 ÆÆ HDPE, UV stabilized outer jacket with low coeffi-
Other fiber counts available on demand cient of friction
ÆÆ Loose tubes (and fillers), SZ stranded around
the CSM
ÆÆ Each PBT tube containing up to 12 optical fibers

Operating temperature

+100
+70°C
+60°C
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

+100
+70°C
-15°C
+55°C
temperature [°C]

-30°C
INSTALLATION

TRANSPORT
OPERATION

-40°C

-100

-30°C

-100

fiber optic cables 2017 | 59


microduct MK-LXs6/7/8 MICRODUCT MK-LXS6/7/8

1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT)
5
with colored fibers in filling gel
3. Fillers
4. Central strength member (FRP) 6
5. Water blocking yarns on FRP
6. Water blocking yarns on strand
element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LXS6 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera-
[N/10 cm]
tube [mm] ÆÆ Flexible network design
[kg/km] lation tion
ÆÆ Distribution network
6T x 4F 24 4 6 6 0 5.3 18
6T x 6F 36 6 6 6 0 5.3 18
6T x 8F 48 8 6 6 0 5.3 19
650 200 500
6T x 10F 60 10 6 6 0 5.3 19 Features
4T x 12F 48 10 6 4 2 5.3 20 ÆÆ HDPE, UV stabilized outer jacket with low coeffi-
6T x 12F 72 12 6 6 0 5.3 21 cient of friction
ÆÆ Loose tubes (and fillers), SZ stranded around
MetroJET MK-LXS7 the CSM
ÆÆ PBT tubes containing up to 12 optical fibers
Nominal Max. tensile
Fibers Ø load [N]
Total Active weight Crush
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera-
[N/10 cm]
tube [mm]
[kg/km] lation tion Operating temperature
8T x 4F 32 4 8 8 0 6.2 28
+100
8T x 6F 48 6 8 8 0 6.2 28 +70°C
8T x 8F 64 8 8 8 0 6.2 29 1200 350 500 +55°C
temperature [°C]

INSTALLATION

8T x 10F 80 10 8 8 0 6.2 30
OPERATION

TRANSPORT

8T x 12F 96 12 8 8 0 6.2 31
+100
-15°C
+70°C
MetroJET MK-LXS8
+55°C
-30°C
Nominal Max. tensile
temperature [°C]

INSTALLATION

Fibers Ø load [N]


-40°C
Total Active weight Crush
TRANSPORT
OPERATION

Version Fibers per Fillers ± 5%


elements tubes ±10% instal- opera- [N/10 cm]
tube [mm]
[kg/km] lation tion
-100
12T x 4F 48 4 12 12 0 7.8 47
-30°C
12T x 6F 72 6 12 12 0 7.8 48
12T x 8F 96 8 12 12 0 7.8 49 1500 550 500
12T x 10F 120 10 12 12 0 7.8 50
-100
12T x 12F 144 12 12 12 0 7.8 52
Other fiber counts available on demand

60 | fiber optic cables 2017


microduct MK-LXs9/10 MICRODUCT MK-LXS9/10

3 1 2
Cable structure
1. HDPE outer jacket 4
5
2. Loose tubes (PBT) with colored
fibers in filling gel 6
3. Fillers
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking tape on strand 7
element
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LXS9 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera-
[N/10 cm]
tube [mm] ÆÆ Flexible network design
[kg/km] lation tion
ÆÆ Distribution network
14T x
168 12 18 14 4 8.7 53
12F
16T x
192 12 18 16 2 8.7 54 650 200 500
12F
18T x Features
216 12 18 18 0 8.7 55
12F
ÆÆ HDPE, UV stabilized outer jacket with low coeffi-
MetroJET MK-LXS10 cient of friction
Nominal Max. tensile ÆÆ Loose tubes (and fillers), SZ stranded around
Fibers Ø load [N] the CSM
Total Active weight Crush
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera-
[N/10 cm] ÆÆ PBT tubes containing up to 12 optical fibers
tube [mm]
[kg/km] lation tion
24T x
288 12 24 24 0 9.3 72 1000 250 500
12F Operating temperature
Other fiber counts available on demand
+100
+70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-15°C

-30°C
-40°C

-100

fiber optic cables 2017 | 61


microduct MK-LX6 MICRODUCT MK-LX6

1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT) with colored
5
fibers in filling gel
3. Fillers
4. Central strength member (FRP) 6
5. Water blocking yarns on FRP
6. Water blocking yarns
on strand element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LX6 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Flexible network design
lation tion
ÆÆ Distribution network
1T x 4F 4 4 6 1 5 5.6 28
1T x 6F 6 6 6 1 5 5.6 28
1T x 8F 8 8 6 1 5 5.6 28
2T x 6F 12 6 6 2 4 5.6 29 Features
4T x 6F 24 6 6 4 2 5.6 29 ÆÆ HDPE, UV stabilized outer jacket with low friction
6T x 6F 36 6 6 6 0 5.6 29 ÆÆ Loose tubes (and fillers), SZ stranded around
750 250 1000 the CSM
1T x 12F 12 12 6 1 5 5.6 30
ÆÆ PBT tubes containing 4-12 optical fibers
2T x 12F 24 12 6 2 4 5.6 30
ÆÆ Smallest diameter for blowing into 8 mm (ID)
3T x 12F 36 12 6 3 3 5.6 30 ducts
4T x 12F 48 12 6 4 2 5.6 31
5T x 12F 60 12 6 5 1 5.6 32
Operating temperature
6T x 12F 72 12 6 6 0 5.6 33
+100
Other fiber counts available on demand
+70°C
+55°C
Available colors
temperature [°C]

INSTALLATION

OPERATION

T-Telecom (according to IEC 60304) - Fibers


TRANSPORT

1-12 1 2 3 4 5 6 7 8 9 10 11 12
-15°C
Code
-30°C
Color red green blue white violet orange grey yellow brown pink black aqua -40°C

T-Telecom (according to IEC 60304) - Tubes


-100
Tube 1 2 3 4 5 6

Code

Color red green blue white violet orange

*In case of lower fiber count some tubes can be replaced by fillers.

62 | fiber optic cables 2017


microduct MK-LX7 MICRODUCT MK-LX7

1
3 2
Cable structure
1. HDPE outer jacket 4
2. Loose tubes (PBT) with colored
fibers in filling gel 5
3. Fillers 6
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking yarns on strand
element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LX7 Applications

Nominal Max. tensile load ÆÆ Microduct cabling air-blowing system


Fibers Total Ø [N]
Active weight Crush ÆÆ Metro networks
Version Fibers per ele- Fillers ± 5%
tubes ±10% instal- opera- [N/10 cm]
tube ments [mm] ÆÆ Flexible network design
[kg/km] lation tion
ÆÆ Distribution network
8T x 4F 32 4 8 8 0 6.7 36
8T x 6F 48 6 8 8 0 6.7 37
1600 600 1000
8T x 8F 64 8 8 8 0 6.7 38
8T x 12F 96 12 8 8 0 6.7 39 Features
Other fiber counts available on demand ÆÆ HDPE, UV stabilized outer jacket with low friction
ÆÆ Loose tubes (and fillers), SZ stranded around
Available colors the CSM
T-Telecom (according to IEC 60304) - Fibers ÆÆ PBT tubes containing 4-12 optical fibers
ÆÆ Smallest diameter for blowing into 8* and 10 mm
1-12 1 2 3 4 5 6 7 8 9 10 11 12
(ID) ducts
Code

Color red green blue white violet orange grey yellow brown pink black aqua * - blowing range may be lower

T-Telecom (according to IEC 60304) - Tubes Operating temperature


Tube 1 2 3 4 5 6 7 8 +100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

*In case of lower fiber count some tubes can be replaced by fillers.

-15°C

-30°C
-40°C

-100

fiber optic cables 2017 | 63


microduct MK-LX8 MICRODUCT MK-LX8

1
3
Cable structure 2
1. HDPE outer jacket 4

2. Loose tubes (PBT) with colored


fibers in filling gel 5
3. Fillers
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking yarns 6
on strand element
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
7

Configuration

MetroJET MK-LX8 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Flexible network design
lation tion
ÆÆ Distribution network
1T x 12F 12 12 12 1 11 8.6 53
2T x 12F 24 12 12 2 10 8.6 54
3T x 12F 36 12 12 3 9 8.6 55
4T x 12F 48 12 12 4 8 8.6 56 Features
2500 600 1000
5T x 12F 60 12 12 5 7 8.6 57 ÆÆ HDPE, UV stabilized outer jacket with low friction
6T x 12F 72 12 12 6 6 8.6 57 ÆÆ Loose tubes (and fillers), SZ stranded around
the CSM
8T x 12F 96 12 12 8 4 8.6 59
ÆÆ PBT tubes containing 4-12 optical fibers
12T x 12F 144 12 12 12 0 8.6 62
ÆÆ Smallest diameter for blowing into 12 mm (ID)
Other fiber counts available on demand ducts

Available colors Operating temperature


T-Telecom (according to IEC 60304) - Fibers
+100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
+55°C
Code
temperature [°C]

INSTALLATION

OPERATION

Color
TRANSPORT

red green blue white violet orange grey yellow brown pink black aqua

T-Telecom (according to IEC 60304) - Tubes -15°C

Tube 1 2 3 4 5 6 7 8 9 10 11 12 -30°C
-40°C
Code

Color red green blue white violet orange grey yellow brown pink black aqua -100
*In case of lower fiber count some tubes can be replaced by fillers.

64 | fiber optic cables 2017


microduct MK-LX9 MICRODUCT MK-LX9

3 1 2
Cable structure
1. HDPE outer jacket 4
5
2. Loose tubes (PBT) with colored
fibers in filling gel 6
3. Fillers
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking yarns on strand 7
element
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1

Configuration

MetroJET MK-LX9 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Flexible network design
lation tion
ÆÆ Distribution network
14T x 12F 168 12 18 14 4 8.8 62
16T x 12F 192 12 18 16 2 8.8 63 750 250 1000
18T x 12F 216 12 18 18 0 8.8 64
Other fiber counts available on demand Features

ÆÆ HDPE, UV stabilized outer jacket with low friction


ÆÆ Loose tubes (and fillers), SZ stranded around
Available colors
the CSM
T-Telecom (according to IEC 60304) - Fibers ÆÆ PBT tubes containing up to 12 optical fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ Smallest diameter for blowing into 12 mm (ID)
ducts
Code

Color red green blue white violet orange grey yellow brown pink black aqua Operating temperature

T-Telecom (according to IEC 60304) - Tubes +100


+70°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12 +55°C
temperature [°C]

Code
INSTALLATION

OPERATION

TRANSPORT

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer -15°C
**In case of lower fiber count some tubes can be replaced by fillers
-30°C
-40°C

-100

fiber optic cables 2017 | 65


microduct MK-LX11 MICRODUCT MK-LX11

1
3
Cable structure
1. HDPE outer jacket 4
2
2. Fillers
3. Loose tubes (PBT)
with colored fibers 5
in filling gel 6
4. Central strength member
(FRP)
5. Water blocking yarns on FRP 7

Optimal Low Telecom Blowing Microduct 6. Water blocking yarns on strand


diameter friction installation Generation 1
element
7. Ripcord
Configuration

MetroJET MK-LX11 Applications

Nominal Max. tensile ÆÆ Microduct cabling air-blowing system


Fibers Ø load [N]
Total Active weight Crush ÆÆ Metro networks
Version Fibers per Fillers ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Flexible network design
lation tion
ÆÆ Distribution network
20T x 12F 240 12 24 20 4 10.8 85
22T x 12F 264 12 24 22 2 10.8 86 1000 350 1000
24T x 12F 288 12 24 24 0 10.8 87
Other fiber counts available on demand Features

ÆÆ HDPE, UV stabilized outer jacket with low friction


Available colors ÆÆ Loose tubes (and fillers), SZ stranded around
the CSM
T-Telecom (according to IEC 60304) - Fibers
ÆÆ PBT tubes containing up to 12 optical fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ Smallest outer diameter for blowing into 12 mm
(ID) ducts
Code

Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
T-Telecom (according to IEC 60304) - Tubes
+100
Tube 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
+55°C
Code
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -15°C

-30°C
-40°C

-100

66 | fiber optic cables 2017


Telecom
Duct
telecom duct bdc-MSA TELECOM DUCT BDC-MSA

1 2
Cable structure
3
1. HDPE outer jacket
2. Fiberglass yarns
3. PET tape 7
4. Water blocking yarns on FRP 4
5
5. Central strength member
(FRP) 6
6. Loose tubes (PBT) with colored
fibers in filling gel 8
Telecom Duct Basic 7. Fillers
Rodent 8. Ripcord
Protection

Configuration

telecom duct BDC-msa Applications

Nominal Max. tensile load ÆÆ Installation into existing ducts


Fibers Ø [N]
Total Active weight PE Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±5% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion

1T x 12F 12 12 6 1 8.2 50 1500 550


1-6T x 4F 4-24 4 6 1-6 8.2 50 1550 780
1T x 6F 6 6 6 1 8.2 50 1550 780 Features
2T x 6F 12 6 6 2 8.2 50 1550 780
ÆÆ HDPE outer jacket
2T x 12F 24 12 6 2 8.2 51 1500 550 ÆÆ Optical fibers
4T x 6F 24 6 6 4 8.2 51 1550 780 ÆÆ Jelly into the Loose tube
3T x 12F 36 12 6 3 8.2 52 1500 550 ÆÆ Loose tubes (PBT Ø 1.8 mm) with filling
compound
6T x 6F 36 6 6 6 8.2 53 1550 780
ÆÆ PET tape to prevent moisture into the cable
4T x 12F 48 12 6 4 8.2 53 1500 550 1500
5T x 12F 60 12 6 5 8.2 54 1500 550
Operating temperature
6T x 12F 72 12 6 6 8.2 54 1500 550
8T x 4F 48 4 8 8 9.3 70 1650 750 +100

8T x 12F 96 12 8 8 9.3 71 1620 750 +70°C


+55°C
11T x 12F 132 12 12 11 11.5 102 1620 850
temperature [°C]

INSTALLATION

OPERATION

12T x 12F 144 12 12 12 11.5 104 1620 850


TRANSPORT

13T x 12F 156 12 14 13 12.6 126 2100 850


-5°C
14T x 12F 168 12 14 14 12.6 126 2100 850
-20°C
Other fiber counts available on demand
-40°C

Available colors -100


T-Telecom (according to IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua

*In case of lower fiber count some tubes can be replaced by fillers.

68 | fiber optic cables 2017


telecom duct BDC-MIB TELECOM BDC-MIB

1
2
Cable structure
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection

Configuration

telecom duct BDC-MIB Applications

Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers Ø load [N]
Total Active weight Crush ÆÆ Fully dielectric cable
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Basic rodent protection
lation tion

1-6T x 6F 6-36 6 6 1-6 8.8 63 2800 1500


1-6T x 12F 12-72 12 6 1-6 8.8 66 2800 1000
8T x 6F 48 6 8 8 10.0 77 2800 1500 Features
8T x 12F 96 12 8 8 10.0 82 2800 1000 1500
ÆÆ FRP strength and anti-buckling rod
12T x 12F 144 12 12 12 12.2 117 2800 1000 ÆÆ Dry yarns to prevent moisture into the cable
16-18T x 12F 192-216 12 18 16-18 12.6 122 2800 1000 ÆÆ Loose tubes (PBT Ø 1,8mm) with filling compound

20-24T x 12F 240-288 12 24 20-24 14.2 156 2800 1000 ÆÆ Optical fibers
ÆÆ Fibreglass yarns as tensile elements
Other fiber counts available on demand
ÆÆ UV stabilized HDPE jacket
Available colors
T-Telecom (according to IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink black aqua
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12 -15°C

Code
-40°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -100

fiber optic cables 2017 | 69


telecom duct BDC-c0 TELECOM DUCT BDC-C0

Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection

Configuration

telecom duct bdc-c0 Applications

Nominal Max. tensile load ÆÆ Installation into existing ducts


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Fully dielectric cable
lation tion
ÆÆ Basic rodent protection
1T x 4F 4 4 6 1 10.0 71 2100 1300
1T x 6F 6 6 6 2
2T x 6F 12 6 6 2 10.0 71 2100 1300
4T x 6F 24 6 6 4 Features
1T x 12F 12 12 6 1
ÆÆ FRP strength and anti-buckling element
2T x 12F 24 12 6 2 ÆÆ Optical fibers
3T x 12F 36 12 6 3 ÆÆ Loose tube with filling compound (PBT Ø 2.0 mm)
10.0 74 2000 1000
4T x 12F 48 12 6 4 2000 ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Fiberglass yarns as tensile elements
5T x 12F 60 12 6 5
ÆÆ UV stabilized HDPE jacket
6T x 12F 72 12 6 6
8T x 12F 96 12 8 8 11.3 97 2100 1000
12T x 12F 144 12 12 12 13.8 144 2200 1100 Operating temperature

16T x 12F 192 12 18 16 14.2 148 2200 1100


18T x 12F 216 12 18 18 14.2 150 2200 1100
24T x 12F 288 12 24 24 16.2 190 2500 1200 +100
Other fiber counts available on demand +70°C
+55°C
temperature [°C]

INSTALLATION

Available colors
TRANSPORT
OPERATION

T-Telecom (according to IEC 60304) - Fibers


1-12 1 2 3 4 5 6 7 8 9 10 11 12 -15°C

Code
-40°C

Color red green blue white violet orange grey yellow brown pink black aqua

-100
t-telecom (according to IEC 60304) - Tubes
Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers

70 | fiber optic cables 2017


telecom duct BDC-CI TELECOM BDC-CI

Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection

Configuration

telecom duct bdc-cI Applications

Nominal Max. tensile ÆÆ Installation into existing ducts


Fibers Ø load [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Fully dielectric cable
lation tion
ÆÆ Basic rodent protection
1T x 4F 4 4 6 1 10.0 74 2800 1700
1T x 6F 6 6 6 1
10.0 74 2800 1700
2T x 6F 12 6 6 2
1T x 12F 12 12 6 1 10.0 73 2700 1200 Features
4Tx 6F 24 6 6 4 10.0 74 2800 1600 ÆÆ FRP strength and anti-buckling element
2T x 12F 24 12 6 2 10.0 75 2700 1200 ÆÆ Optical fibers
3Tx 12F 36 12 6 3 ÆÆ Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ Dry yarns to prevent moisture into the cable
4T x 12F 48 12 6 4 10.0 82 2700 1200
ÆÆ Fiberglass yarns as tensile elements
6T x 12F 72 12 6 6
2000 ÆÆ UV stabilized HDPE jacket
8T x 12F 96 12 8 8 11.4 101 2700 1200
12T x 12F 144 12 12 12 13.8 146 2700 1200
Operating temperature
13T x 12F 156 12 18 13 14.2 149
14T x 12F 168 12 18 14 14.2 150 +100

15T x 12F 180 12 18 15 14.2 151 +70°C


2900 1400 +55°C
16T x 12F 192 12 18 16 14.2 152
temperature [°C]

INSTALLATION

17T x 12F 204 12 18 17 14.2 153


TRANSPORT
OPERATION

18T x 12F 216 12 18 18 14.2 154


-15°C
24T x 12F 288 12 24 24 16.3 191 2900 1400
Other fiber counts available on demand
-40°C

Available colors
T-Telecom (according to IEC 60304) - Fibers -100

1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer

fiber optic cables 2017 | 71


telecom duct BDC-ck TELECOM DUCT BDC-CK

Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6

Telecom Duct Basic member (FRP)


Rodent 8
Protection
Configuration

telecom duct bdc-ck


Nominal Max. tensile load
Fibers Ø [N] Applications
Total Active weight Crush
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Installation into existing ducts
lation tion
ÆÆ High tensile and crush performance
1T x 4F 4 4 6 1 10.1 77
ÆÆ Fully dielectric cable
1T x 6F 6 6 6 1 10.1 78
4000 2400 ÆÆ Basic rodent protection
1T x 8F 8 8 6 1 10.1 79
1T x 10F 10 10 6 1 10.1 80
1T x 12F 12 12 6 1 10.2 81 4100 2000
2T x 6F 12 6 6 2 10.1 78 4000 2400 Features

2T x 12F 24 12 6 2 10.2 81 4100 2000 ÆÆ FRP strength and anti-buckling element


4T x 6F 24 6 6 4 10.1 79 4000 2400 ÆÆ Optical fibers
ÆÆ Loose tube with filling compound (PBT Ø 2.0 mm)
3T x 12F 36 12 6 3 10.2 82 4100 2000
ÆÆ Dry yarns to prevent moisture into the cable
6T x 6F 36 6 6 6 10.1 82 4000 2400 2000
ÆÆ Fiberglass yarns as tensile elements
4T x 12F 48 12 6 4 10.2 83 4100 2000 ÆÆ UV stabilized HDPE jacket
8T x 6F 48 6 8 8 11.4 98 4100 2700
5T x 12F 60 12 6 5 10.2 84
4100 2000 Operating temperature
6T x 12F 72 12 6 6 10.2 85
8T x 12F 96 12 8 8 11.4 104 4200 2300 +100
+70°C
12T x 12F 144 12 12 12 13.9 151 4200 2000
+55°C
16T x 12F 192 12 18 16 14.1 191
temperature [°C]

4100 1800
INSTALLATION

TRANSPORT

18T x 12F 216 12 18 18 14.1 191


OPERATION

24T x 12F 288 12 24 24 15.9 240 4000 1900


-15°C
Other fiber counts available on demand

Available colors -40°C

T-Telecom (according to IEC 60304) - Fibers


1-12 1 2 3 4 5 6 7 8 9 10 11 12 -100

Code

Color red green blue white violet orange grey yellow brown pink black aqua

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers

72 | fiber optic cables 2017


telecom duct BDC-DI TELECOM BDC-DI

Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection

Configuration

telecom duct bdc-DI Applications

Nominal Max. tensile ÆÆ For installation into existing duct


Fibers Ø load [N]
Total Active weight Crush or directly buried
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm] ÆÆ Fully dielectric cable
tube [mm] [kg/km]
lation tion
ÆÆ Basic rodent protection
1-6T x 6F 6-36 6 6 1-6 11,5 98 3400 2400
1-6T x 12F 12-72 12 6 1-6 11,5 99 3000 1900
8T x 12F 96 12 8 8 13,1 126 3000 1900
12T x 12F 144 12 12 12 16,2 193 3000 1900 Features
4000
16T x 12F 192 12 18 16 17,0 195 3000 1900 ÆÆ FRP strength and anti-buckling element
18T x 12F 216 12 18 18 17,0 197 3000 1900 ÆÆ Dry yarns and tape to prevent moisture into the
cable
20T x 12F 240 12 24 20 19,4 252 3000 1900
ÆÆ Loose tube (PBT Ø 2.5mm) with filing compound
24T x 12F 288 12 24 24 19,4 260 3000 1900 ÆÆ Optical fibers
Other fiber counts available on demand ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
Available colors ÆÆ Fibreglass yarns as strain relief
T-Telecom (according to IEC 60304) - Fibers ÆÆ UV stabilized PE sheath
ÆÆ Sheath options: LSOH, PA etc.
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature

+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]

INSTALLATION

Code
TRANSPORT
OPERATION

Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C

-100

fiber optic cables 2017 | 73


telecom duct BDC-DK TELECOM DUCT BDC-DK

1
2
Cable structure 3
1. PE sheath 7. Loose tubes (PBT)
2. Glass yarns 8. Optical fibers 6 4
3. Filling compound 9. Ripcord
4. Water swellable yarns 5
5. Water swellable tape
6. Central strength member
7
(FRP)

Telecom Basic Duct 8


9
Rodent
Protection

Configuration

telecom duct bdc-Fk Applications

Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø [N]
Total Active weight Crush ÆÆ Fully dielectric cable
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Basic rodent protection
lation tion

1-6T x 4F 4-24 4 6 1-6 11.5 98 4200 2800


1-6T x 6F 6-36 6 6 1-6 11.5 99 4200 2800
1-6T x 12F 12-72 12 6 1-6 11.5 100 4000 2400 Features
8T x 12F 96 12 8 8 13.1 129 4200 2600 ÆÆ FRP strength and anti-buckling element
12T x 12F 144 12 12 12 16.2 196 4200 2600 4000 ÆÆ Dry yarns and tape to prevent moisture into the
cable
16T x 12F 192 12 18 16 17.0 198 4000 2400
ÆÆ Loose tube (PBT Ø 2.5mm) with filing compound
18T x 12F 216 12 18 18 17.0 202 4000 2400
ÆÆ Optical fibers
20T x 12F 240 12 24 20 19.4 255 4200 2600 ÆÆ Fillers (if applicable)
24T x 12F 288 12 24 24 19.4 263 4200 2600 ÆÆ Water-swellable tape

Other fiber counts available on demand ÆÆ Fibreglass yarns as strain relief


ÆÆ UV stabilized PE sheath
ÆÆ Sheath options: LSOH, PA etc.
Available colors
T-Telecom (according to IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Operating temperature
Code
+100
Color red green blue white violet orange grey yellow brown pink black aqua +70°C
+55°C
temperature [°C]

t-telecom (according to IEC 60304) - Tubes


INSTALLATION

TRANSPORT
OPERATION

Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code -15°C

Color red green blue white violet orange grey yellow brown pink black aqua
-40°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-100

74 | fiber optic cables 2017


telecom duct ddc-SI TELECOM DUCT DDC-SI

1 2
Cable structure
3
1. HDPE outer jacket 7
4
2. Fiberglass yarns
3. HDPE inner jacket 5
4. Water blocking yarns
5. Central strength member (FRP)
6. Loose tubes (PBT) 6
with colored fibers in filling gel
7. Fillers
Telecom High Duct Direct 8. Ripcords
Rodent buried
Protection 8

Configuration

telecom duct DDC-SI Applications

Nominal Max. tensile ÆÆ Installation into existing ducts


Fibers Ø load [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% al- [N/10 cm]
tube [mm] [kg/km] static ÆÆ Fully dielectric cable
lowed
ÆÆ High rodent protection
1-6T x 4F 4 - 24 4 6 1-6 9.3 67 2800 800
8T x 4F 32 4 8 8 10.3 83 2700 650
1-6T x 6F 6 - 36 6 6 1-6 9.4 68 2800 800
8T x 6F 48 6 8 8 10.4 85 2800 800 2000 Features
1-6T x 12F 12 - 72 12 6 1-6 9.4 73 2700 650 ÆÆ FRP strength and anti-buckling element
8T x 12F 96 12 8 8 10.4 88 2700 670 ÆÆ Optical fibers
12T x 12F 144 12 12 12 12.3 122 2800 670 ÆÆ Loose tube (PBT Ø 1.6mm) with filling compound
ÆÆ Dry yarns to prevent moisture into the cable
Other fiber counts available on demand
ÆÆ Fiberglass yarns as tensile and water absorbent
elements
Available colors
ÆÆ Double HDPE jacket
T-Telecom (according to IEC 60304) - Fibers ÆÆ LS0H, PA etc. outer jacket option
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
+70°C
t-telecom (according to IEC 60304) - Tubes +55°C
temperature [°C]

Tube 1 2 3 4 5 6 7 8 9 10 11 12
INSTALLATION

TRANSPORT
OPERATION

Code

Color red green blue white violet orange grey yellow brown pink black aqua -15°C

*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -40°C

-100

fiber optic cables 2017 | 75


telecom duct ddc-ci TELECOM DUCT DDC-CI

1 2
Cable structure
3
1. HDPE outer jacket 6. Loose tubes (PBT) 7
4
2. Fiberglass yarns with colored fibers
3. HDPE inner jacket in filling gel 5
4. Water blocking 7. Fillers
yarns 8. Ripcords
5. Central strength 6
member (FRP)

Telecom High Duct Direct Hi-crush


Rodent buried
Protection 8

Configuration

telecom duct DDC-ci Applications

Nominal Max. tensile ÆÆ Installation into existing ducts


Fibers Ø load [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% al- [N/10 cm]
tube [mm] [kg/km] static ÆÆ Fully dielectric cable
lowed
ÆÆ High rodent protection
1-6T x 4F 4 - 24 4 6 1-6 11.7 73 4400 2600
1-6T x 6F 6 - 36 6 6 1-6 11.7 73 4400 2600
1-6T x 12F 12 - 72 12 6 1-6 11.8 105 4100 2000
8T x 6F 48 6 8 8 13.0 124 4100 2300 Features
8T x 12F 96 12 8 8 13.0 128 4100 2000 3500 ÆÆ FRP strength and anti-buckling element
12T x 12F 144 12 12 12 15.5 180 4600 2200 ÆÆ Optical fibers

16T x 12F 192 12 16 16 15.9 185 4600 2200 ÆÆ Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ Dry yarns and tape to prevent moisture into the
18T x 12F 216 12 18 18 15.9 187 4600 2200 cable
24T x 12F 288 12 24 24 17.6 193 5000 2600 ÆÆ Glass yarns as tensile elements
Other fiber counts available on demand ÆÆ Double HDPE jacket
ÆÆ LS0H, PA etc. outer jacket option

Available colors
T-Telecom (according to IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink black aqua
temperature [°C]

INSTALLATION

TRANSPORT
OPERATION

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12 -15°C

Code
-40°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
-100
**In case of lower fiber count some tubes can be replaced by fillers

76 | fiber optic cables 2017


telecom duct MDC-FM TELECOM DUCT MDC-FM

1
2
Cable structure
1. PE outer jacket (black)
2. Water blocking and strength 3
elements
3. FRP rods incorporated in outer
jacket
4. Optical fibers 4
5
5. LS0H module
6. Ripcord
6

Telecom High Duct


Rodent
Protection
Applications
Configuration ÆÆ Duct cable
telecom duct MDC-FM ÆÆ FTTH access networks
ÆÆ Fully dielectric cable
Nominal Max. tensile
Fibers load [N]
Total Active Ø weight Crush
Version Fibers per
elements modules ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed
5.9 Features
1M x 12F 12 12 1 1 30 800 400
(max 6.4)
7.0 ÆÆ LS0H modules with 12 pcs of optical fibers each
2M x 12F 24 12 2 2 40 800 400
(max 7.5) ÆÆ Water swellable and tensile strength elements
7.2 ÆÆ FRP rods as strength elements (incorporated in
3M x 12F 36 12 3 3 42 800 400
(max 7.7) outer jacket)
7.9 ÆÆ UV resistant black HDPE sheath
4M x 12F 48 12 4 4 49 1000 500
(max 8.4)
ÆÆ Orange polyester rip cord
9.0
6M x 12F 72 12 6 6 55 1600 800
max 9.5)
2000
10.2
8M x 12F 96 12 8 8 85 1800 900 Operating temperature
max 10.7)
11.5
12M x 12F 144 12 12 12 100 2200 1100 +100
(max 12.0)
13.2 +70°C
16M x 12F 192 12 16 16 120 2300 1100 +60°C
(max 13.7) +40°C
temperature [°C]

14.2
18M x 12F 216 12 18 18 140 2500 1200
OPERATION
INSTALLATION

TRANSPORT

(max 14.7)
15.2
24M x 12F 288 12 24 24 140 2700 1300
(max 15.7) -5°C
Other fiber counts available on demand -30°C
-40°C
Available colors
T-Telecom (according to IEC 60304) - Fibers
-100
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua

t-telecom (according to IEC 60304) - Tubes


Tube 1 2 3 4 5 6 7 8 9 10 11 12

Code

Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers

fiber optic cables 2017 | 77


armored SSC-CI ARMORED SSC-CI

1
Cable structure 2
3
1. LSOH sheath 7
4
2. Corrugated steel tape
3. Fiberglass yarns 5
4. Water swellable yarns and tape
5. Central strength member (FRP)
6. Loose tube with optical fibers 6
in filling compound
7. Fillers
Telecom High Duct Direct 8. Ripcord
Rodent buried
Protection 8

Configuration

armored SSC-CI Applications

Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements modules ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed

1-6T x 12F 12-72 12 6 1-6 11.4 154 2700 1400


8T x 12F 96 12 8 8 12.6 187 2700 1400 Features
12T x 12F 144 12 12 12 14.2 250 2700 1400
ÆÆ FRP strength and anti-buckling element
16T x 12F 192 12 16 16 15.2 264 2700 1400 3500 ÆÆ Dry yarns and tape to prevent moisture into the
18T x 12F 216 12 18 18 15.2 267 2700 1400 cable
ÆÆ Loose tube (PBT Ø 2.0mm) with filing compound
20T x 12F 240 12 24 20 17.2 305 2700 1400
ÆÆ Optical fibers
24T x 12F 288 12 24 24 17.2 309 2700 1400
ÆÆ Fillers (if applicable)
Other fiber counts available on demand ÆÆ Water-swellable tape
ÆÆ Fibreglass yarns as strain relief
ÆÆ Corrugated steel tape armouring
Available colors
ÆÆ UV stabilized LSOH sheath / black or grey (other
T-Telecom (according to IEC 60304) - Fibers colours available on demand)
ÆÆ Sheath options: PE, PA etc.
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]

INSTALLATION

Code
TRANSPORT
OPERATION

Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C

-100

fiber optic cables 2017 | 79


armored SSC-T30U ARMORED SSC-T30U

1 2 3
Cable structure
1. PE sheath
2. Corrugated steel tape
3. Fiberglass yarns 4
4. Loose tube (PBT) with optical
fibers in filling compound
5. Ripcord
5

Telecom Rodent Duct Direct


Protection buried
High

Configuration

armored SSC-T30U Applications

Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements tubes ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed

1T x 2-24F 2-24 2-24 1 1 7.6 69 1500 750


1T x 2-24F 3000
2-24 2-24 1 1 7.6 84 1500 750 Features
LSOH
Other designs available on demand ÆÆ Loose tube (PBT Ø 3.0mm) with filing compound
ÆÆ Optical fibers
ÆÆ Fibreglass yarns as strain relief
Available colors ÆÆ Corrugated steel tape armouring
T-Telecom (according to IEC 60304) - Fibers ÆÆ UV stabilized PE sheath (black), option: LSOH
sheath (grey by default, other colors available)
1-12 1 2 3 4 5 6 7 8 9 10 11 12 option: LSOH sheath (grey by default, other colors
available)
Code

Color red green blue white violet orange grey yellow brown pink black aqua

Operating temperature
t-telecom (according to IEC 60304) - Tubes
+100
Tube 1 2 3 4 5 6 7 8 9 10 11 12
+70°C
Code +55°C
temperature [°C]

INSTALLATION

Color red green blue white violet orange grey yellow brown pink black aqua
TRANSPORT
OPERATION

*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-15°C

-40°C

-100

80 | fiber optic cables 2017


armored SSC-T30I ARMORED SSC-T30I

1 2 3
Cable structure
1. PE sheath (black) / option: LSOH (grey)
2. Corrugated steel tape
3. Fiberglass yarns
4
4. Loose tube (PBT) with optical
fibers in filling compound
5. Ripcord
5

Telecom Rodent Duct Direct


Protection buried
High

Configuration

armored SSC-T30U Applications

Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements tubes ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed

1T x 2-24F 2-24 2-24 1 1 7.6 69 1800 900


1T x 2-24F 3000
2-24 2-24 1 1 7.6 84 1800 900 Features
LSOH
Other designs available on demand ÆÆ Loose tube (PBT Ø 3.0mm) with filing compound
ÆÆ Optical fibers
ÆÆ Fibreglass yarns as strain relief
Available colors ÆÆ Corrugated steel tape armouring
T-Telecom (according to IEC 60304) - Fibers ÆÆ UV stabilized PE sheath (black), option: LSOH
sheath (grey by default, other colors available)
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]

INSTALLATION

TRANSPORT

Code
OPERATION

Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C

-100

fiber optic cables 2017 | 81


armored DSC-CI ARMORED DSC-CI

1
2
Cable structure
7 3
1. PE jacket 4
2. Corrugated steel tape
3. Fiberglass yarns 5
4. Water swellable yarns and tape
5. Central strength member (FRP)
6. Loose tube (PBT) with optical 6
fibers in filling compound
7. Fillers
Telecom Rodent Duct Direct 8. Ripcords
Protection buried
High 8

Configuration

telecom duct DSC-Ci Applications

Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements modules ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed

1-6T x 6F 6-36 6 6 1-6 11.4 168 2700 1400


1-6T x 12F 12-72 12 6 1-6 11.4 169 2700 1400 Features
8T x 12F 96 12 8 8 13.2 203 2700 1400
ÆÆ FRP strength and anti-buckling element
12T x 12F 144 12 12 12 16.4 269 2700 1400 ÆÆ Dry yarns and tape to prevent moisture into the
4000
16T x 12F 192 12 16 16 16.8 237 2700 1400 cable
ÆÆ Loose tube (PBT Ø 2.0mm) with filing compound
18T x 12F 216 12 18 18 16.8 238 2700 1400
ÆÆ Optical fibers
20T x 12F 240 12 24 20 18.6 290 2700 1400
ÆÆ Fillers (if applicable)
24T x 12F 288 12 24 24 18.6 290 2700 1400 ÆÆ Water-swellable tape
Other fiber counts available on demand ÆÆ Fibreglass yarns as strain relief
ÆÆ Corrugated steel tape armouring
ÆÆ Double UV stabilized PE sheath
Available colors ÆÆ Sheath options: LSOH, PA etc.
T-Telecom (according to IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code Operating temperature

Color red green blue white violet orange grey yellow brown pink black aqua +100
+70°C
+55°C
t-telecom (according to IEC 60304) - Tubes
temperature [°C]

INSTALLATION

Tube 1 2 3 4 5 6 7 8 9 10 11 12
TRANSPORT
OPERATION

Code
-15°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer -40°C
**In case of lower fiber count some tubes can be replaced by fillers

-100

82 | fiber optic cables 2017


Telecom
Aerial
telecom aerialAero-DR03 TELECOM AERIAL Aero-DR03

Cable structure 1 2 3

1. LSOH outer sheath


2. Aramid yarns
3. Central semi tight buffer
tube 900 μm with optical
fiber

Last mile Aerial FTTH Telecom


connection
indoor

Configuration

AERO-DR03
Nominal Tensile load [N]
Fibers Ø
Total Active weight Crush
Version Fibers per
elements tubes
± 5%
±10% [N/10 cm] Applications
tube [mm] allowed static
[kg/km]
ÆÆ For installation on poles
1F 1 1 1 1 3.0 9.5 300 100 3 3000000
ÆÆ Fully dielectric
Other fiber counts available on demand ÆÆ Aerial cable with aramid reinforcement

Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Semi tight buffer with 1 optical fiber (0.9 mm)
Code
ÆÆ Aramid yarns
Color red green blue white violet orange grey yellow brown pink black aqua ÆÆ LSOH outer sheath

13-24 13 14 15 16 17 18 19 20 21 22 23 24

Code Operating temperature


Color red green blue white violet orange grey yellow brown pink natural aqua
+100
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm +70°C
+55°C
temperature [°C]

INSTALLATION

OPERATION

TRANSPORT

-10°C

-40°C
Ice: 0 mm Wind: 94.4 km/h
span: 55 m
-100

sag: 1.1 m

Ice: 3.0 mm Wind: 62.8 km/h


span: 40 m

sag: 0.8 m

Ice: 4.0 mm Wind: 70 km/h


span: 30 m

sag: 0.6 m

84 | fiber optic cables 2017


telecom aerialAero-DF03 TELECOM AERIAL Aero-DF03

1
Cable structure
2 5
1. PE jacket 4. Central loose tube (PBT) 4
3

2. Ripcord with 250 µm colored


3. Water blocking yarns fibers in filling gel
5. FRP strength
member

Last mile Aerial FTTH Telecom


connection
indoor

Cable variants

Version AERO-DF03 AERO-DF03

Fiber count 1-12 16-24


Cable dimensions [mm] 8.3 x 4.6 (±3%)
Applications
8.7 x 5.0 (±3%)
Cable weight [kg/km] 37 38 ÆÆ Installation on poles or walls
Max. installation tension[N] 1300 1300 ÆÆ Can be installed in pipelines
ÆÆ Fully dielectric cable
Mechanical and enviromental characteristics

Parameter

Crush performance 5000 N


Features
Bending performance 10 cycles [20 x D]
Water Penetration 3 m sample, 1 m head, 24 h ÆÆ Loose tube with filling compound (PBT)
ÆÆ Up to 24 fibers in a cable
Available colors ÆÆ Two FRP strength elements
ÆÆ Dry yarns to prevent moisture into cable
T-Telecom (according to IEC 60304) - Fibers in tube
ÆÆ Ripcord yarns For easy jacket removal
1-12 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ PE UV resistant Jacket
Code

Color red green blue white violet orange grey yellow brown pink black aqua Operating temperature
13-24 13 14 15 16 17 18 19 20 21 22 23 24
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink natural aqua
temperature [°C]

INSTALLATION

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
TRANSPORT
OPERATION

NESC Light
-15°C
span: 120 m

-40°C

sag: 2.4 m
-100
NESC Medium
span: 70 m

sag: 1.4 m

NESC Heavy
span: 40 m

sag: 0.8 m

fiber optic cables 2017 | 85


telecom aerialAero-DDF03 TELECOM AERIAL Aero-DDF03

1 2 3 4
Cable structure
1. PE sheath 4. Loose tube with filling
2. Ripcord compound
3. Water blocking yarns 5. FRP rods
reinforcement
5

Last mile Aerial FTTH Telecom


connection indoor

Cable variants

Version AERO-DDF03

Fibre count [pcs] 4-48


9.3 x 4.8 Applications
Cable dimensions [mm]
(typically ±0.3 max 9.7 x 5.3)
ÆÆ Installation on poles or walls
Cable weight [kg/km] 50
ÆÆ Can be installed in pipelines
Max. operational tension [N] 500
ÆÆ Fully dielectric cable
Max allowable tension [N] 1800

Mechanical and enviromental characteristics

Parameter Features
Crush performance 5000 N
ÆÆ Loose tube with filling compound (PBT)
Bending performance 10 cycles [20 x D]
ÆÆ Up to 24 fibers in a cable
Water Penetration 3 m sample, 1 m head, 24 h ÆÆ Two FRP strength elements
ÆÆ Dry yarns to prevent moisture into cable
Available colors ÆÆ Ripcord yarns for easy jacket removal
T-Telecom (according to IEC 60304) - Fibers in tube ÆÆ PE UV resistant jacket

1-12 1 2 3 4 5 6 7 8 9 10 11 12

Code Operating temperature


Color red green blue white violet orange grey yellow brown pink black aqua
+100
13-24 13 14 15 16 17 18 19 20 21 22 23 24 +70°C
+55°C
Code
temperature [°C]

INSTALLATION

Color red green blue white violet orange grey yellow brown pink natural aqua
TRANSPORT
OPERATION

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
-15°C

NESC Light
-40°C
span: 135 m

-100
sag: 2.1 m

NESC Medium
span: 80 m

sag: 1.2 m

NESC Heavy
span: 45 m

sag: 0.7 m

86 | fiber optic cables 2017


telecom aerialAero-AS02 2.0 mm TELECOM AERIAL Aero-AS02 2.0 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS02 PBT TUBES 2.0 mm Applications


Nominal Tensile load [N] ÆÆ Duct & pole mount
Fibers Ø
Total Active weight Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% allowed static
[N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km]
ÆÆ Self-supporting aerial cable with aramid
1-6T x 6F 6 – 36 6 6 1–6 10.0 73 2200 1200
reinforcements
1-6T x 12F 12 – 72 12 6 1–6 10.0 75 2100 1000
2000
8T x 12F 96 12 8 8 11.3 98 2200 1100
12T x 12F 144 12 12 12 13.8 143 2100 1000
Features
Other fiber counts available on demand
ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket

NESC Light
span: 130 m

sag: 2.6 m

NESC Medium
span: 85 m

sag: 1.7 m

NESC Heavy
span: 45 m

sag: 0.9 m

fiber optic cables 2017 | 87


telecom aerialAero-AS03 2.0 mm TELECOM AERIAL Aero-AS03 2.0 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration

AERO-AS02 PBT TUBES 2.0 mm


Nominal Tensile load [N] Applications
Fibers Ø
Total Active weight Crush
Version Fibers per ± 5%
elements tubes ±10% allowed static
[N/10 cm]
ÆÆ Duct & pole mount
tube [mm]
[kg/km]
ÆÆ High tensile and crush performance
1-6T x 6F 6-36 6 6 1-6 10.0 75 3200 1800
ÆÆ Fully dielectric cable
1-6T x 12F 12-72 12 6 1-6 10.1 77 3100 1500 ÆÆ Self-supporting aerial cable with aramid
2000 reinforcements
8T x 12F 96 12 8 8 11.3 100 3100 1500
12T x 12F 144 12 12 12 13.8 146 3100 1500
Other fiber counts available on demand
Features
Available colors
T-Telecom (according to IEC 60304) - Fibers ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
Code ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
Color red green blue white violet orange grey yellow brown pink black aqua
ÆÆ Fillers (if applicable)
t-telecom (according to IEC 60304) - Tubes ÆÆ Water-swellable tape
Tube 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket
Code

Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
*In case of lower fiber count some tubes can be replaced by fillers.
+100
NESC Light +70°C
span: 190 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 3.8 m

-15°C
NESC Medium
-40°C
span: 130 m

-100
sag: 2.6 m

NESC Heavy
span: 75 m

sag: 1.5 m

88 | fiber optic cables 2017


telecom aerialAero-AS03 2.5 mm TELECOM AERIAL Aero-AS03 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS03 PBT TUBES 2.5 mm Applications

Nominal Max. tensile load ÆÆ Duct & pole mount


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion
ÆÆ Self-supporting aerial cable with aramid
1-6T x 6F 6-36 6 6 1-6 11.4 97 3300 2200 reinforcements
1-6T x 12F 12-72 12 6 1-6 11.4 98 3200 2100
3000
8T x 12F 96 12 8 8 13.0 127 3200 2100
12T x 12F 144 12 12 12 16.1 193 3300 2200
Features
Other fiber counts available on demand
ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket

Operating temperature

+100
NESC Light +70°C
span: 190 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 3.8 m

-15°C
NESC Medium
-40°C
span: 140 m

-100
sag: 2.8 m

NESC Heavy
span: 80 m

sag: 1.6 m

fiber optic cables 2017 | 89


telecom aerialAero-AS04 2.0 mm TELECOM AERIAL Aero-AS04 2.0 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS04 PBT TUBES 2.0 mm Applications

Nominal Max. tensile load ÆÆ Duct & pole mount


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion
ÆÆ Self-supporting aerial cable with aramid
1T x 12F 12 12 6 1 10,1 75 4000 2000 reinforcements
2T x 6F 12 6 6 2 10,1 75 4100 2400
2T x 12F 24 12 6 2 10,1 76 4000 2000
4T x 6F 24 6 6 4 10,1 76 4100 2400
Features
3T x 12F 36 12 6 3 10,1 80 4000 2000
6T x 6F 36 6 6 6 10,1 76 4100 2400 2000 ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
4T x 12F 48 12 6 4 10,1 80 4000 2000
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
8T x 6F 48 6 8 8 11.3 97 4200 2500
ÆÆ 6-12 elements SZ stranded cable core
6T x 12F 72 12 6 6 10,1 82 4000 2000 ÆÆ Optical fibers
8T x 12F 96 12 8 8 11,4 103 4200 2100 ÆÆ Fillers (if applicable)
12T x 12F 144 12 12 12 13,9 149 4100 2000 ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
Other fiber counts available on demand
ÆÆ UV stabilized HDPE jacket

Operating temperature

+100
NESC Light +70°C
span: 250 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 5.0 m

-15°C
NESC Medium
-40°C
span: 170 m

-100
sag: 3.4 m

NESC Heavy
span: 95 m

sag: 1.9 m

90 | fiber optic cables 2017


telecom aerialAero-AS04 2.5 mm TELECOM AERIAL Aero-AS04 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS04 PBT TUBES 2.5 mm Applications

Nominal Max. tensile load ÆÆ Duct & pole mount


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion
ÆÆ Self-supporting aerial cable with aramid
1-6T x 6F 6-36 6 6 1-6 11.4 98 4200 2900 reinforcements
1-6T x 12F 12-72 12 6 1-6 11.4 99 4100 2600
3000
8T x 12F 96 12 8 8 13.1 128 4200 2800
12T x 12F 144 12 12 12 16.2 194 4100 2700
Features
Other fiber counts available on demand
ÆÆ FRP strength and anti-buckling element

APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction) ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.5 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket

Operating temperature

+100
NESC Light +70°C
span: 250 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 5.0 m

-15°C
NESC Medium
-40°C
span: 170 m

-100
sag: 3.4 m

NESC Heavy
span: 95 m

sag: 1.9 m

fiber optic cables 2017 | 91


telecom aerialAero-AS06 2.0 mm TELECOM AERIAL Aero-AS06 2.0 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS06 PBT TUBES 2.0 mm Applications


Max. tensile load ÆÆ Duct & pole mount
Qty Nominal
Ø [N]
Active weight Crush ÆÆ High tensile and crush performance
Version Fibers ± 5%
Total tubes ±10% instal- opera- [N/10 cm] ÆÆ Fully dielectric cable
Fibers per [mm]
elements [kg/km] lation tion ÆÆ Self-supporting aerial cable with aramid
tube
reinforcements
1-6T x 6F 6-36 6 6 1-6 10.2 82 6100 3600
1-6T x 12F 12 12 6 1-6 10.3 88 6200 3000
2000
8T x 12F 96 12 8 8 11.5 110 6200 2800
12T x 12F 144 12 12 12 13.9 154 6100 3000 Features

Other fiber counts available on demand ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket

Operating temperature

+100
NESC Light +70°C
span: 360 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 7.2 m

-15°C
NESC Medium
-40°C
span: 250 m

-100
sag: 5.0 m

NESC Heavy
span: 140 m

sag: 2.8 m

92 | fiber optic cables 2017


telecom aerialAero-AS06 2.5 mm TELECOM AERIAL Aero-AS06 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS06 PBT TUBES 2.5 mm Applications

Nominal Max. tensile load ÆÆ Duct & pole mount


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion
ÆÆ Self-supporting aerial cable with aramid
1-6T x 6F 6-36 6 6 1-6 11.6 101 6100 4200 reinforcements
1-6T x 12F 12-72 12 6 1-6 11.6 104 6300 4100
3000
8T x 12F 96 12 8 8 13.2 132 6100 4000
12T x 12F 144 12 12 12 16.2 198 6100 4000
Features
Other fiber counts available on demand
ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.5 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket

Operating temperature

+100
NESC Light +70°C
span: 370 m +55°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

sag: 7.4 m

-15°C
NESC Medium
-40°C
span: 270 m

-100
sag: 5.4 m

NESC Heavy
span: 150 m

sag: 3.0 m

fiber optic cables 2017 | 93


telecom aerialAero-AS09 2.5 mm TELECOM AERIAL Aero-AS09 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS09 PBT TUBES 2.5 mm Applications


Max. tensile load ÆÆ Duct & pole mount
Qty Nominal
Ø [N]
Active weight Crush ÆÆ High tensile and crush performance
Version Fibers ± 5%
Total tubes ±10% instal- opera- [N/10 cm] ÆÆ Fully dielectric cable
Fibers per [mm]
elements [kg/km] lation tion ÆÆ Self-supporting aerial cable with aramid
tube
reinforcements
1-6T x 6F 6-36 6 6 1-6 11.6 101 9300 6600 ÆÆ UV resistant
1-6T x 12F 12-72 12 6 1-6 11.7 104 9200 6000
3000
8T x 12F 96 12 8 8 13.2 138 9200 6100
12T x 12F 144 12 12 12 16.2 203 9200 6100
Other fiber counts available on demand Features

ÆÆ FRP strength and anti-buckling element Ø 2.5 mm


APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
ÆÆ Optical fibers
ÆÆ Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Dry yarns to prevent moisture into cable
ÆÆ Aramid yarns as tensile elements

Operating temperature

+100
+70°C
+55°C
temperature [°C]

NESC Light
OPERATION
INSTALLATION

TRANSPORT

span: 530 m

-15°C
sag: 10.6 m
-40°C

NESC Medium
span: 400 m
-100

sag: 8.0 m

NESC Heavy
span: 230 m

sag: 4.6 m

94 | fiber optic cables 2017


telecom aerialAero-AS12 2.5 mm TELECOM AERIAL Aero-AS12 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS12 PBT TUBES 2.5 mm Applications

Nominal Max. tensile load ÆÆ Duct & pole mount


Fibers Ø [N]
Total Active weight Crush ÆÆ High tensile and crush performance
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] ÆÆ Fully dielectric cable
[kg/km] lation tion
ÆÆ Self-supporting aerial cable with aramid
1-6T x 6F 6-36 6 6 1-6 11.7 106 12700 9000 reinforcements
1-6T x 12F 12-72 12 6 1-6 11.8 110 12500 8000 ÆÆ UV resistant
3000
8T x 12F 96 12 8 8 13.3 143 12200 7800
12T x 12F 144 12 12 12 16.3 208 12100 8000

Other fiber counts available on demand


Features

ÆÆ FRP strength and anti-buckling element


APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction)
ÆÆ Optical fibers
ÆÆ Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Dry yarns to prevent moisture into cable
ÆÆ Aramid yarns as tensile elements

Operating temperature

+100
+70°C
+55°C
temperature [°C]

NESC Light
OPERATION
INSTALLATION

TRANSPORT

span: 700 m

-15°C
sag: 14 m
-40°C

NESC Medium
span: 530 m
-100

sag: 10.6 m

NESC Heavy
span: 310 m

sag: 6.2 m

fiber optic cables 2017 | 95


telecom aerialAero-AS14 2.5 mm TELECOM AERIAL Aero-AS14 2.5 mm

1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH

Configuration

AERO-AS14 PBT TUBES 2.5 mm Applications


Max. tensile load ÆÆ Duct & pole mount
Qty Nominal
Ø [N]
Active weight Crush ÆÆ High tensile and crush performance
Version Fibers ± 5%
Total tubes ±10% instal- opera- [N/10 cm] ÆÆ Fully dielectric cable
Fibers per [mm]
elements [kg/km] lation tion ÆÆ Self-supporting aerial cable with aramid
tube
reinforcements
1-6T x 6F 6-36 6 6 1-6 11.8 109 14400 10100 ÆÆ UV resistant
1-6T x 12F 12-72 12 6 1-6 11.8 113 14500 9400
3000
8T x 12F 96 12 8 8 13.4 147 14200 9100
12T x 12F 144 12 12 12 16.4 211 14000 9200
Other fiber counts available on demand Features

ÆÆ FRP strength and anti-buckling element


APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction) ÆÆ Optical fibers
ÆÆ Loose tube with filling compound (PBT Ø 2.5 mm)
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Dry yarns to prevent moisture into cable
ÆÆ Aramid yarns as tensile elements

Operating temperature

+100
+70°C
+55°C
temperature [°C]

NESC Light
OPERATION
INSTALLATION

TRANSPORT

span: 800 m

-15°C
sag: 16.0 m
-40°C

NESC Medium
span: 600 m
-100

sag: 12.0 m

NESC Heavy
span: 350 m

sag: 7.0 m

96 | fiber optic cables 2017


Special
Cable Designs
special design FTTA-DAC special design FTTA-DAC

Cable structure
1. Outer jacket PE 5
2

2. Fiberglass yarns 3

3. Loose tube (PBT)


with colored fibers in filling gel
4. Ripcords
5. Embedded strength members (FRP)
4

FTTA Aerial Hi-crush Compact


design

Configuration

FTTA-DAC Applications
Ø Nominal Max. tensile load [N] ÆÆ Fiber to the antenna system ( FTTA)
Fibers per Crush
Version Fibers ± 5% weight
tube installation operation
[N/10 cm] ÆÆ Optical access cable with fiber glass yarns
[mm] ±10% [kg/km]
reinforcement
1T x 2F 2 2 5.8 31 ÆÆ Direct buried construction
1T x 4F 4 4 5.8 31 ÆÆ Fully dielectric cable
800
1T x 6F 6 6 5.8 31 (ε=0.33%) ÆÆ Last mile connection
250 3500
1T x 8F 8 8 5.8 32 1200
(ε=0.50%)
1T x 12F 12 12 5.8 32
1T x 24F 24 24 6.3 38
Features

ÆÆ Fiberglass yarns as water-blocking and strain relief


Available colors elements
T-Telecom (according to IEC 60304) - Fibers ÆÆ Loose tube (PBT) with filing compound
ÆÆ Optical fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Embedded strength members (FRP)
Code

Color red green blue white violet orange grey yellow brown pink black aqua

13-24 13 14 15 16 17 18 19 20 21 22 23 24 Operating temperature

Code +100
+70°C
Color red green blue white violet orange grey yellow brown pink natural aqua
+50°C
temperature [°C]

*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
OPERATION
INSTALLATION

TRANSPORT

-15°C

-45°C

-100

98 | fiber optic cables 2017


BDC-CIP 1.5 mm2 hybrid cables BDC-CIP 1.5 mm2
hybrid power+fo
1
Cable structure 2

1. HDPE outer jacket 5. Water blocking tape 3


2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 1.5 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-CIP 1.5 mm2 Applications


Nominal Max. tensile load ÆÆ Installation into existing ducts
Fibers Ø
Total Active weight [N] Crush or directly buried
Version Fibers per ± 5%
elements tubes ±10% [N/10 cm]
tube [mm] allowed static ÆÆ High tensile and crush performance
[kg/km]
1T x 12F
12 12 6 1 10.7 127 2700 1300
+2x1.5 mm2
1T x 12F
12 12 6 1 10.7 170 2700 1300
+4x1.5 mm2 Features
2T x 12F
24 12 6 2 10.7 107 2700 1300
+1x1.5 mm2 ÆÆ FRP strength and anti-buckling element
2T x 12F ÆÆ Loose tube with filling compound (PBT Ø 2.2mm)
24 12 6 2 10.7 128 2700 1300
+2x1.5 mm2 ÆÆ Tubes with copper core
2T x 12F
24 12 6 2 10.7 171 2700 1300 ÆÆ Dry yarns to prevent moisture into the cable
+4x1.5 mm2
ÆÆ UV stabilized HDPE jacket
3T x 12F
36 12 6 3 10.7 129 2700 1300 2700 ÆÆ LS0H, PA etc Jacket option
+2x1.5 mm2
4T x 12F
48 12 6 4 10.7 130 2700 1300
+2x1.5 mm2
1T x 12F Operating temperature
12 12 8 1 12.1 231 2700 1300
+6x1.5 mm2
+100
2T x 12F
24 12 8 2 12.1 232 2700 1300
+6x1.5 mm2 +70°C
3T x 12F +55°C
36 12 8 3 12.1 190 2700 1300
temperature [°C]

+4x1.5 mm2
OPERATION
INSTALLATION

TRANSPORT

4T x 12F
48 12 8 4 12.1 191 2700 1300
+4x1.5 mm2

Other fiber and copper wire counts available on demand -15°C

-40°C
Technical copper wire characteristics
Max DC resistance 12,1±0,2 Ω/km@20°C
-100
Electric strength 3400 V DC/1 minute

Current carrying capacity 7A

Operating voltage 65V AC/DC

Conductor material Bare copper

Conductor cross section 1,5mm2

Insulated conductor dia. 2,2mm

Insulation material PVC

fiber optic cables 2017 | 99


BDC-CIP 0.5 mm2 H05V-U hybrid cables BDC-CIP 0.5 mm2
hybrid power+fo
1
2
Cable structure
1. HDPE outer jacket 5. Water blocking tape 3
2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 0.5 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-CIP 0.5 mm2 H05V-U Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F
12 12 6 1 10.1 89 2700 1000
+2x0.5 mm2
1T x 12F
12 12 6 1 10.1 105 2700 1000 Features
+4x0.5 mm2
1T x 12F ÆÆ FRP strength and anti-buckling element
12 12 6 1 10.1 113 2700 1000
+5x0.5 mm2 ÆÆ Insulated copper cores 0.5 mm2 (Ø 2.0 mm)
2T x 12F ÆÆ Loose tubes with filling compound (PBT Ø 2.0
24 12 6 2 10.1 90 2700 1000
+2x0.5 mm2 mm)
2T x 12F ÆÆ Tape and dry yarns to prevent moisture into the
24 12 6 2 10.1 106 2700 1000
+4x0.5 mm2 cable
3T x 12F ÆÆ Fiberglass yarns as strain relief elements
36 12 6 3 10.1 91 2700 1000 2700
+2x0.5 mm2
ÆÆ UV stabilized HDPE outer jacket
4T x 12F
48 12 6 4 10.1 92 2700 1000 ÆÆ Other outer jackets materials available
+2x0.5 mm2
5T x 12F
60 12 6 5 10.1 85 2700 1000
+1x0.5 mm2
1T x 12F Operating temperature
12 12 8 1 11.4 127 2800 1100
+6x0.5 mm2
2T x 12F +100
24 12 8 2 11.4 128 2800 1100
+6x0.5 mm2 +70°C
4T x 12F +55°C
48 12 8 4 11.4 120 2800 1100
+4x0.5 mm2
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

Other fiber and copper wire counts available on demand

-15°C
Technical copper wire characteristics
-40°C
Max DC resistance 36,0 Ω/km@20°C

Conductor material Bare copper


-100
Conductor cross section 0.5 mm2

Insulated conductor dia. 2.0 mm

Insulation material PVC

100 | fiber optic cables 2017


BDC-CIP 0.75 mm2 H05V-U hybrid cables BDC-CIP 0.75 mm2
hybrid power+fo
1
Cable structure 2

1. HDPE outer jacket 5. Water blocking tape 3


2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 0.75 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-CIP 0.75 mm2 H05V-U Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F
12 12 6 1 10.7 99 2700 1300
+2x0.75 mm2
1T x 12F
12 12 6 1 10.7 114 2700 1300 Features
+4x0.75 mm2
2T x 12F ÆÆ FRP strength and anti-buckling element
24 12 6 2 10.7 100 2700 1300
+2x0.75 mm2 ÆÆ Insulated copper cores 0.75mm2 (Ø 2.2mm)
2T x 12F ÆÆ Loose tubes with filling compound (PBT Ø 2.2mm)
24 12 6 2 10.7 115 2700 1300
+4x0.75 mm2
ÆÆ Tape and dry yarns to prevent moisture into the
3T x 12F cable
36 12 6 3 10.7 101 2700 1300
+2x0.75 mm2
2700 ÆÆ Fiberglass yarns as strain relief elements
4T x 12F
48 12 6 4 10.7 102 2700 1300 ÆÆ UV stabilized HDPE outer jacket
+2x0.75 mm2
1T x 12F ÆÆ Other outer jackets materials available
12 12 8 1 12.1 147 2700 1300
+6x0.75 mm2
2T x 12F
24 12 8 2 12.1 148 2700 1300
+6x0.75 mm2 Operating temperature
3T x 12F
36 12 8 3 12.1 134 2700 1300 +100
+4x0.75 mm2
4T x 12F +70°C
48 12 8 4 12.1 135 2700 1300
+4x0.75 mm2 +55°C
temperature [°C]

Other fiber and copper wire counts available on demand


OPERATION
INSTALLATION

TRANSPORT

Technical copper wire characteristics -15°C

Max DC resistance 24.0 Ω/km@20°C -40°C

Conductor material Bare copper


-100
Conductor cross section 0.75 mm2

Insulated conductor dia. 2.2 mm

Insulation material PVC

fiber optic cables 2017 | 101


BDC-CIP 1.00 mm2 H05V-U hybrid cables BDC-CIP 1.00 mm2
hybrid power+fo
1
2
Cable structure
1. HDPE outer jacket 5. Water blocking tape 3
2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 1.0 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-CIP 1.0 mm2 H05V-U Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F
12 12 6 1 10.7 104 2700 1300
+2x1.00 mm2
1T x 12F
12 12 6 1 10.7 124 2700 1300 Features
+4x1.00 mm2
2T x 12F ÆÆ FRP strength and anti-buckling element
24 12 6 2 10.7 105 2700 1300
+2x1.00 mm2 ÆÆ Insulated copper cores 1.00 mm2 (Ø 2.3 mm)
2T x 12F ÆÆ Loose tubes with filling compound (PBT Ø 2.2
24 12 6 2 10.7 125 2700 1300
+4x1.00 mm2 mm)
3T x 12F ÆÆ Tape and dry yarns to prevent moisture into the
24 12 6 2 10.7 125 2700 1300
+2x1.00 mm2 cable
4T x 12F ÆÆ Fiberglass yarns as strain relief elements
48 12 6 4 10.7 107 2700 1300
+2x1.00 mm2
ÆÆ UV stabilized HDPE outer jacket
5T x 12F
60 12 6 5 10.7 98 2700 1300 2700 ÆÆ Other outer jackets materials available
+1x1.00 mm2
1T x 12F
12 12 8 1 12.1 162 2700 1300
+6x1.00 mm2
1T x 12F Operating temperature
12 12 8 1 12.1 162 2700 1300
+6x1.00 mm2
+100
2T x 12F
24 12 8 2 12.1 163 2700 1300
+6x1.00 mm2 +70°C
3T x 12F +55°C
36 12 8 3 12.1 144 2700 1300
temperature [°C]

+4x1.00 mm2
OPERATION
INSTALLATION

TRANSPORT

3T x 12F
36 12 8 3 12.1 144 2700 1300
+4x1.00 mm2
4T x 12F
48 12 8 4 12.1 145 2700 1300
+4x1.00 mm2 -15°C

Other fiber and copper wire counts available on demand -40°C

Technical copper wire characteristics -100

Max DC resistance 18.1 Ω/km@20°C

Conductor material Bare copper

Conductor cross section 1.00 mm2

Insulated conductor dia. 2.3 mm

Insulation material PVC

102 | fiber optic cables 2017


BDC-DIP 1.5 mm2 H07V-U hybrid cables BDC-DIP 1.5 mm2
hybrid power+fo
1
Cable structure 2

1. HDPE outer jacket 5. Water blocking tape 3


2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 1.5 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-DIP 1.5 mm2 H07V-U Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F
12 12 6 1 12.4 137 2700 1500
+2x1.5 mm2
1T x 12F
12 12 6 1 12.4 166 2700 1500 Features
+4x1.5 mm2
2T x 12F ÆÆ FRP strength and anti-buckling element
24 12 6 2 12.4 138 2700 1500
+2x1.5 mm2 ÆÆ Insulated copper cores 1.50 mm2 (Ø 2.8 mm)
2T x 12F ÆÆ Loose tubes with filling compound (PBT Ø 2.8
24 12 6 2 12.4 167 2700 1500
+4x1.5 mm2 mm)
3T x 12F ÆÆ Tape and dry yarns to prevent moisture into the
36 12 6 3 12.4 140 2700 1500
+2x1.5 mm2 cable
4T x 12F ÆÆ Fiberglass yarns as strain relief elements
48 12 6 4 12.4 141 2700 1500 2700
+2x1.5 mm2
ÆÆ UV stabilized HDPE outer jacket
5T x 12F
60 12 6 5 12.4 128 2700 1500 ÆÆ Other outer jackets materials available
+1x1.5 mm2
1T x 12F
12 12 8 1 14.2 228 3000 1800
+6x1.5 mm2
2T x 12F Operating temperature
24 12 8 2 14.2 229 3000 1800
+6x1.5 mm2
+100
3T x 12F
36 12 8 3 14.2 202 3000 1800
+4x1.5 mm2 +70°C
4T x 12F +55°C
48 12 8 4 14.2 203 3000 1800
temperature [°C]

+4x1.5 mm2
OPERATION
INSTALLATION

TRANSPORT

Other fiber and copper wire counts available on demand

Technical copper wire characteristics -15°C

Max DC resistance 12.1 Ω/km@20°C -40°C

Conductor material Bare copper


-100
Conductor cross section 1.5 mm2

Insulated conductor dia. 2.8 mm

Insulation material PVC

fiber optic cables 2017 | 103


BDC-DIP 2.5 mm2 H07V-U hybrid cables BDC-DIP 2.5 mm2
hybrid power+fo
1
2
Cable structure
1. HDPE outer jacket 5. Water blocking tape 3
2. Fiberglass yarns 6. Central strength
3. Loose tubes (PBT) member (FRP) 6
with colored fibers in 7. 2.5 mm2 Cu –
filling gel insulated copper 4
4. Water blocking yarns wire 5
on FRP 8. Ripcord
7

FTTH Duct Rodent Hybrid


Protection FO+Power 8
Basic

Configuration

BDC-DIP 2.5 mm2 H07V-U Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F
12 12 6 1 13.7 175 2800 1700
+2x2.5 mm2
1T x 12F
12 12 6 1 13.7 223 2800 1700 Features
+4x2.5 mm2
2T x 12F ÆÆ FRP strength and anti-buckling element
24 12 6 2 13.7 177 2800 1700
+2x2.5 mm2 ÆÆ Insulated copper cores 2.50 mm2 (Ø 3.3 mm)
2T x 12F ÆÆ Loose tubes with filling compound (PBT Ø 3.2
24 12 6 2 13.7 225 2800 1700
+4x2.5 mm2 mm)
3T x 12F ÆÆ Tape and dry yarns to prevent moisture into the
36 12 6 3 13.7 179 2800 1700
+2x2.5 mm2 cable
4T x 12F ÆÆ Fiberglass yarns as strain relief elements
48 12 6 4 13.7 180 2800 1700 2700
+2x2.5 mm2
ÆÆ UV stabilized HDPE outer jacket
5T x 12F
60 12 6 5 13.7 158 2800 1700 ÆÆ Other outer jackets materials available
+1x2.5 mm2
1T x 12F
12 12 8 1 15.7 311 2800 1700
+6x2.5 mm2
2T x 12F Operating temperature
24 12 8 2 15.7 313 2800 1700
+6x2.5 mm2
+100
3T x 12F
36 12 8 3 15.7 267 2800 1700
+4x2.5 mm2 +70°C
4T x 12F +55°C
48 12 8 4 15.7 268 2800 1700
temperature [°C]

+4x2.5 mm2
OPERATION
INSTALLATION

TRANSPORT

Other fiber and copper wire counts available on demand

Technical copper wire characteristics -15°C

Max DC resistance 7.41 Ω/km@20°C -40°C

Conductor material Bare copper


-100
Conductor cross section 2.5 mm2

Insulated conductor dia. 3.3 mm

Insulation material PVC

104 | fiber optic cables 2017


hybrid power+fo BDC-DID 0.8 mm hybrid cables BDC-DID 0.8 mm

1
Cable structure 2
3
1. HDPE outer jacket 5. Water blocking tape
2. Fiberglass yarns 6. Central strength 3
3. Loose tubes (PBT) member (FRP)
with colored fibers in 7. 2x Ø 0.8/1.3 5
4
filling gel insulated Cu pair
4. Water blocking yarns 8. Ripcord 6
on FRP
7 8
FTTH Duct Rodent Hybrid
Protection FO+Power
Basic

Configuration

BDC-DID 0.8 mm Applications


Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø
Total Active weight [N] Crush
Version Fibers per ± 5% ÆÆ High tensile and crush performance
elements tubes ±10% [N/10 cm]
tube [mm] allowed static
[kg/km]
1T x 12F +
12 12 8 1 13.1 162
7x2x0,8Cu
2T x 12F + Features
24 12 8 2 13.1 161
6x2x0,8Cu
3T x 12F + ÆÆ FRP strength and anti-buckling element
36 12 8 3 13.1 160
5x2x0,8Cu ÆÆ Insulated copper pairs 2xØ 0.8/1.3 mm
4T x 12F + ÆÆ Loose tubes with filling compound (PBT Ø 2.5
48 12 8 4 13.1 158 2900 1900 2000
4x2x0,8Cu mm)
5T x 12F + ÆÆ Tape and dry yarns to prevent moisture into the
60 12 8 5 13.1 157
3x2x0,8Cu cable
6T x 12F + ÆÆ Fiberglass yarns as strain relief elements
72 12 8 6 13.1 156
2x2x0,8Cu
ÆÆ UV stabilized HDPE outer jacket
7T x 12F +
84 12 8 7 13.1 154 ÆÆ Other outer jackets materials available
1x2x0,8Cu

Other fiber and copper wire counts available on demand


Operating temperature
Technical copper wire characteristics
+100
Standard PN-EN 50290-1-1:2002 +70°C
+55°C
Maximum resistance of wire loop 75 Ω/km@20°C
temperature [°C]

OPERATION
INSTALLATION

TRANSPORT

Insulation resistance 1500 MΩ·km

Material of conductor Copper


-15°C

Nominal diameter of conductor 0.8 mm -40°C

Nominal diameter of insulation 1.3 mm


-100
Insulation material PE

fiber optic cables 2017 | 105


NOTES

fiber optic cables 2017 NOTES | 106


FIBRAIN SP. Z O.O.
Rogoźnica 312
36-060 Głogów Małopolski