Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Information Page 5
Application Page 5 5
FOC Parameters Page 6
Low Loss Fibers Page 7
SM/MM Bendsafe Fibers Page 9
Page 10
Fiber and Cables Information
Page 11
Fiber Identification
DATACOM Page 17
Furcation tube FSMX Page 17 16
Buffer BFR Page 18
Simplex SMX Page 19
DC-PRIM-14 Page 21
DC-PRIM-20 Page 22
DC-PRIM Page 23
DC-DRIM Page 24
Duplex ZIP Page 25
DC-T40 Page 26
LDC Page 27
LBR Page 28
EXO-FU Page 29
EXO-FI Page 30
EXO-GU Page 31
EXO-G0 Page 32
EXO-GI Page 33
BDC-MSA Page 34
FTTH Page 35
VC-D20 Page 37 35
VC-D30 Page 38
VC-D40 Page 39
VC-DCY Page 40
Resibend® Cables Page 41
VC-D30 Resibend® Page 42
VC-D30 Resibend Plus® Page 43
Easy Section Module® Cables Page 44
VC-D20 Easy Section Module® Page 45
VC-D30 Easy Section Module® Page 46
VC-D40 Easy Section Module® Page 47
DC-PRIM Page 48
EAC-RAs Page 49
EAC-RAm Page 50
DAC-BURRY Page 51
DAC-BURRY-G Page 52
VC-T601-PE Page 53
VC-T60 Page 54
ver. 2.0.6
fiber optic cables fibrain content
MICRODUCT Page 55
MK-AX2 Page 57 55
MK-LX4 Page 58
MK-LX5 Page 59
MK-LXS6/7/8 Page 60
MK-LXS9/10 Page 61
MK-LX6 Page 62
MK-LX7 Page 63
MK-LX8 Page 64
MK-LX9 Page 65
MK-LX11 Page 66
ver. 2.0.6
Information
symbols
Rodent
Basic Rodent High Rodent Protection
Protection Protection Extreme Blowing
installation
Mechanical features
Last mile
Flexible connection outdoor Aerial Hi-crush
Duct Microduct
Direct buried Generation 1 ETR
Optimal
Diameter
Branch of business
Ship Datacenter
Robotic Windfarms
and offshore
Multifiber
connectors Last Mile
Flexible Easy to terminate Indoor Connection
termination
Hybrid FO
+ Power
Bendsafe Low Friction
Bending loss
Mandrel R=30 mm 100 turns Mandrel R=25 mm 1310/1550 nm 100 turns Mandrel R=15 mm 10 turn
G.652D
1550/1625 nm ≤0.03 dB 0.03 dB 1550 nm ≤0.25 dB 1625 nm ≤1.0 dB
Mandrel R=30 mm 100 turns Mandrel R=25 mm 1310/1550 nm 100 turns Mandrel R=15 mm 10 turn
G.652D LL
1550/1625 nm ≤0.03 dB 0.03 dB 1550 ≤0.25 dB 1625 nm≤1.0 dB
Mandrel R=30 mm 100 turns Mandrel R=15 mm 1550/1625 nm 1 turn
G.655 – A.B.C.D
1550/1625 nm ≤0.05dB ≤0.5 dB
Mandrel R=30 mm 100 turns Mandrel R=15 mm 1550/1625 nm 1 turn
G.656 – A.B.C.D
1550/1625 nm ≤0.05 dB ≤0.5 dB
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn 1550 nm
G.657A1
1550nm≥0.20 dB. 1625 nm ≤0.50 dB ≥0.50 dB. 1625 nm ≤1.50 dB
Mandrel R=15 mm 10 turns Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn
G.657A2
1550 nm≥0.03 dB. 1625nm ≤0.10 dB 1550 nm≥0.10 dB. 1625 nm ≤0.2dB; 1550 nm ≥0.50 dB. 1625 nm ≤1.0 dB
Mandrel R=10 mm 1 turn Mandrel R=7.5 mm 1 turn 1550 nm Mandrel R=5 mm 1 turn
G.657B3
1550 nm≥0.03 dB. 1625 nm ≤0.10 dB ≥0.05 dB. 1625 nm ≤0.15 dB 1550 nm≥0.10 dB. 1625 nm ≤0.30 dB
Mandrel R=5 mm 1 turn Mandrel R=2.5 mm 1 turn 1550 nm
G.657B3 Plus
1550 nm≥0.10 dB. 1625nm ≤0.20 dB ≥0.20 dB. 1625 nm ≤0.30dB
low loss fibers Low Loss Fibers
At present, low loss and pure quartz optic fibers with max. 0.17 dB/km The chromatic dispersion complies with ITU-T G.652 and the polari-
attenuation at 1550 nm wavelength and max. 0.31 dB/km at 1310 nm zing at the level of ≤ 0.04 ps/√km of these fibers provides the pos-
wavelength are ready for use. Low loss and pure quartz optic fibers have at sibility of using such fibers in high- speed systems e.g. transmission
least 0.02 dB/km lower spectral attenuation in comparison to the standard of 10 GBit/s or even higher. Low loss fibers which are obtained
ones G.652D. In such fibers, the retention of flat spectral characteristics in the pure quartz technology can work properly in telecommunica-
within the transmission windows provide the possibility of achieving sub- tion networks at the distance of even thousand kilometers far, which
stantially smaller deviations of attenuation: significantly limits the number of necessary amplifiers and repeaters
ÆÆ 1310 nm (+ 20 nm / -35 nm) wavelength – max. deviation is 0.03 in a fiber optic connection.
dB/km
ÆÆ 1550 nm ( + 25 nm / -25 nm) wavelength – max. deviation is 0.02
dB/km with the retention of 1625 nm attenuation 0.20 dB/km.
Attenuation / Wavelength
0.40
Attenuation [dB/km]
0.30
0.20
G.652.D LL
G.652.D LL
G.652.D LL
G.652.D LL
G.652.D LL
G.657.A1
G.657.A1
G.657.A1
G.657.A1
G.657.A1
G.652.D
G.652.D
G.652.D
G.652.D
G.652.D
0.10
0
13
13
14
15
16
10
83
90
50
25
Wavelength [nm]
Performance Specifications
Parameter Value
Attenuation [dB/km]
1310 nm ≤ 0.32
1383 ± 3 nm ≤ 0.32
1490 nm ≤ 0.21
1550 nm ≤ 0.18
1625 nm ≤ 0.20
Attenuation Difference [dB/km]
λ1 λ2 λ3 Δ
The attenuation from λ1 [nm] to λ2 [nm] shall not exceed the attenu- 1285 1330 1310 0.03
ation at λ3 [nm] by more than Δ
1525 1575 1550 0.02
Point Discontinuity [dB]
1310 nm and 1550 nm ≤ 0.05
Optical Return Loss [dB]
Absolute value at all points along the fiber ≥ 60
Turns mm nm dB
1 32 1550 ≤0.03
Attenuation with Bending [dB] 100 50 1310 ≤0.03
100 50 1550 ≤0.03
100 60 1625 ≤0.03
BEND RADIUS BEND RADIUS BEND RADIUS BEND RADIUS BEND RADIUS
2.5 5 7.5 10 30
mm mm mm mm mm
Bendsafe SM Fibers
G.652D G.652D LL G.655 - A.B.C.D G.656 - A.B.C.D G.657A1 G.657A2 G.657B3 G.657B3 Plus
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
0.05dB
0.03dB
0.03dB
0.03dB
0.03dB
0.05dB
Bend radius [mm]
30
15
10
7,5
Bendsafe MM Fibers
50/125 OM2 50/125 OM3 50/125 OM4
Bend Insensitive Bend Insensitive Bend Insensitive
60
Bending loss for wavelength
850nm 1300nm/both [dB]
0.10dB 0.30dB
0.20dB 0.50dB
0.10dB 0.30dB
0.20dB 0.50dB
0.10dB 0.30dB
0.20dB 0.50dB
40
Bend radius [mm]
30
15
10
7,5
* values for OM1 Tube Gel 900 µm outer coating 250 µm coating
Stripping
11 3
Color red green blue white violet orange grey yellow brown pink black aqua 10 4
13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5
8 6
Code 7
Color red green blue white violet orange grey yellow brown pink natural aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
11 3
Color red blue white green violet orange grey yellow brown pink black aqua 10 4
13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5
8 6
Code 7
Color red blue white green violet orange grey yellow brown pink natural aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Color blue orange green brown grey white red black yellow violet pink aqua 10 4
13-24 13 14 15 16 17 18 19 20 21 22 23 24 9 5
8 6
Code 7
Color blue orange green brown grey white red natural yellow violet pink aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Tube 1 2 3 4 5 6 7 8 9 10 11 12 11 3
10 4
Code
9 5
Color red green blue white violet orange grey yellow brown pink black aqua 8
7
6
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
t1-telecom - Loose tube in cable (according to IEC 60304 Table 3 & ZN-11/TPSA-005-02)
1
Tube 1 2 3 4 5 6 7 8 9 10 11 12 12 2
11 3
Code 10 4
Color red blue white green violet orange grey yellow brown pink black aqua 9 5
8 6
7
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
11 3
Code
10 4
Color blue orange green brown grey white red black yellow violet pink aqua 9 5
8 6
**In cable with a multi-layer construction color of the tubes will be repeated in second layer 7
***In case of lower fiber count some tubes can be replaced by fillers
Code 13 4
12 5
Code
Color red green white white white white white white white white white white
**In cable with a multi-layer construction color of the tubes will be repeated in second layer
***In case of lower fiber count some tubes can be replaced by fillers
Fiber, buffer and tubes color codes for Datacom cables range
Other colors available on demand
Fiber
Buffer
Color red green blue yellow white grey brown violet aqua black orange pink
250/900/600 µm
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Fiber
Buffer
Color red green blue yellow white grey brown violet aqua natural orange pink
250 µm
Color* dark
red green blue yellow white grey brown violet brown orange pink
600/900 µm green
Fibers in tubes
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code 24
13
1
14
2
23 15
Color red green blue yellow white grey brown violet aqua black orange pink
22 16
13-24 13 14 15 16 17 18 19 20 21 22 23 24 21 17
20 18
Code 19
Color red green blue yellow white grey brown violet aqua natural orange pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Color red green blue white violet orange grey yellow brown pink black aqua 10 4
**In cable with a multi-layer construction color of the tubes will be repeated in second layer 9 5
***In case of lower fiber count some tubes can be replaced by fillers 8
7
6
D1-DATACOM (according to IEC 60304 ; TIA/EIA 598-A ; TIA/EIA 598-C /Data Center cables)
Fiber in buffer
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Fiber
Buffer
Color blue orange green brown grey white red black yellow violet pink aqua
250/900/600 µm
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Fiber
Code
Color blue orange green brown grey white red natural yellow violet pink aqua
250 µm
Color* dark
blue orange green brown grey white red yellow violet pink aqua
600/900 µm green
Fibers in tubes
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code 24
13
1
14
2
23 15
Color blue orange green brown grey white red black yellow violet pink aqua
22 16
13-24 13 14 15 16 17 18 19 20 21 22 23 24 21 17
20 18
Code 19
Color blue orange green brown grey white red natural yellow violet pink aqua
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
Color red green blue white violet orange grey yellow brown pink black aqua 10 4
**In cable with a multi-layer construction color of the tubes will be repeated in second layer 9 5
***In case of lower fiber count some tubes can be replaced by fillers 8
7
6
Fiber
Buffer
Color red blue green yellow violet white orange grey brown black aqua pink
250 µm
Color red blue green yellow violet white orange grey brown black aqua pink
600/900 µm
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Fiber
Code
Color red blue green yellow violet white orange grey brown black aqua pink
250 µm
Color* dark
red blue green yellow violet white orange grey brown aqua pink
600/900 µm green
Temperature resistance Temperature resistance Temperature resistance Temperature resistance Temperature resistance Temperature resistance
Chemical resistance Chemical resistance Chemical resistance Chemical resistance Chemical resistance Chemical resistance
1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3
3. Central tube 900 μm
TRUE
COLORS
Configuration
FSMX Applications
Max. installation ÆÆ Distribution systems cable
Ø nominal Nominal weight Crush
Version tension
± 5% [mm] ± 5% [kg/km] [N/10 cm] ÆÆ For patchcords and pigtails
(ε=0.5 %) [N]
ÆÆ Terminals connection
FSMX 1.8 1.8/0.9/0.5 4 100 200
FSMX 2.8 2.8/0.9/0.5 8 350 300
Jacket colors
Features
Standard
ÆÆ LS0H with low coefficient of friction
ÆÆ Aramid yarns
ÆÆ Central tube 900 µm
Yellow RAL 1021 White RAL 9010 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet Low-radius bending resistance SM
RGB 196, 97, 140
[ mm ]
Color codes
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
30 G.652
Fiber
G.657A1
Buffer G.657A2/B2
10
7.5 5 G.657B3
Color red green blue yellow white grey brown violet aqua black orange pink 2.5 G.657B3 Plus
900 µm
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-10°C
-40°C
-100
1
2
Cable structure 3
Configuration
BFR Applications
Ø nominal Max. installation Crush ÆÆ Distribution systems cable
Version Fiber qty
± 5% [mm] tension ± 5% [N] [N/10cm]
ÆÆ For patchcords and pigtails
1F 1 0.6 4 ÆÆ Terminals connections
200
1F 1 0.9 5
Features
Available outer jacket colors
ÆÆ Buffer made of LS0H with low coefficient
of friction
ÆÆ 250 µm fiber
ÆÆ Variants with different stripability
SM G.652D SM G.657 MM 62.5/125 OM1 MM 50/125 OM2 MM 50/125 OM3 MM 50/125 OM4
Yellow RAL 1021 A1 / A2 / A3 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet
White RAL 9010 RGB 196, 97, 140 Operating temperature
Stripping
+100
Stripping - length +70°C
Version Fiber qty Stripping
in one piece [cm]
+55°C
1F 1
temperature [°C]
1F 1
OPERATION
TRANSPORT
-5°C
Color codes -10°C
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers
1-12 1 2 3 4 5 6 7 8 9 10 11 12 -40°C
Fiber -100
Buffer
Color red green blue yellow white grey brown violet aqua black orange pink
250/600/900 µm
1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3
3. Central tight buffer tube
600/900 μm with colored
fiber 250 µm
TRUE
COLORS
Configuration
smx Applications
Max. installation ÆÆ Distribution systems cable
Ø nominal Crush
Version Fiber qty tension
± 5% [mm] [N/10 cm] ÆÆ For patchcords and pigtails
(ε=0.5 %) [N]
ÆÆ Terminals connection
1F 1 1.2 50 200
1F 1 1.6 100 300
1F 1 1.8 150 400
1F 1 2.0 200 500 Features
1F 1 2.8 300 800
ÆÆ LS0H with low coefficient of friction
ÆÆ Aramid yarns
Jacket colors ÆÆ Central tight buffer tube 600/900 µm
ÆÆ 250 µm colored fiber
Standard
Yellow RAL 1021 White RAL 9010 Blue RAL 5015 Orange RAL 2003 Aqua RAL 6027 Violet
RGB 196, 97, 140
30 G.652
Fiber
Operating temperature
Buffer
+100
Color red green blue yellow white grey brown violet aqua black orange pink
250/600/900 µm +70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-10°C
-40°C
-100
black aqua
1
Cable structure
2
1. LS0H outer jacket
2. Aramid yarns
3. 250 µm optical fibers 3
TRUE
COLORS
Configuration
DC-PRIM-14 Applications
Outer diameter [mm] (±5%) 1.4 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 100
ÆÆ LAN and FTTX networks
Perm tensile load [N] 50
ÆÆ Distribution network
Weight [kg/km] (±10%) 2 ÆÆ Inside house OLT connection
Min bending radius [mm] 20 ÆÆ Data Center connections cable
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers +100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
+55°C
Fiber
temperature [°C]
INSTALATION
OPERTATION
TRANSPORT
Color red green blue yellow white grey brown violet aqua black orange pink
-5°C
-10°C
-20°C
-100
1
Cable structure
2
1. LSOH outer jacket
2. High modulus aramid strength yarns
3. 250 μm optical fibers 3
TRUE
COLORS
Configuration
DC-PRIM-20 Applications
Outer diameter [mm] (±5%) 2.0 ÆÆ For customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 170
ÆÆ LAN and FTTX networks
Perm tensile load [N] 75
ÆÆ Distribution network,
Weight [kg/km] (±10%) 3 ÆÆ Inside house OLT connection
Min bending radius [mm] 30 ÆÆ Data center connections cable
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Fiber +70°C
Color red green blue yellow white grey brown violet aqua black orange pink +55°C
temperature [°C]
INSTALATION
OPERTATION
TRANSPORT
-5°C
-10°C
-20°C
-100
1
Cable structure
1. LS0H outer jacket 2
2. Aramid yarns
3. 250 µm optical fibers 3
TRUE
COLORS
Configuration
DC-PRIM Applications
Outer diameter [mm] (±5%) 3.0 3.5 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 350 350
ÆÆ LAN and FTTX networks
Weight [kg/km] (±10%) 8 9
ÆÆ Distribution network
Crush [N/10 cm] 350 ÆÆ Inside house OLT connection
Min. bend radius [mm] 45 (depends on fiber type) 60 (depends on fiber type) ÆÆ Data Center connections cable
Features
+55°C
Fiber
temperature [°C]
INSTALLATION
OPERATION
Color red green blue yellow white grey brown violet aqua black orange pink
TRANSPORT
13-24 13 14 15 16 17 18 19 20 21 22 23 24
-5°C
Fiber -10°C
Code
-40°C
Color* red green blue yellow white grey brown violet brown natural orange pink
1 1
Cable structure
2
1. LS0H outer jacket
2
3
2. Aramid yarns
3
3. LS0H inner jacket
4. Aramid yarns 5
5. 250 µm optical fibers 4
TRUE
COLORS
Configuration
DC-DRIM Applications
Outer diameter [mm] (±5%) 4.5 5.0 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Max tensile load (ε=0.5%) [N] 600 600
ÆÆ LAN and FTTX networks
Weight [kg/km] (±10%) 8 9
ÆÆ Distribution network
Crush [N/10cm] 300 ÆÆ Inside house OLT connection
Min. bend radius [mm] 65 (depends on fiber type) 75 (depends on fiber type) ÆÆ Data Center connections cable
Features
Available colors
Operating temperature
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
+100
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
Fiber +55°C
temperature [°C]
Color red green blue yellow white grey brown violet aqua black orange pink
INSTALLATION
OPERATION
TRANSPORT
13-24 13 14 15 16 17 18 19 20 21 22 23 24
-5°C
Fiber
-10°C
Code
Color* red green blue yellow white grey brown violet brown natural orange pink -40°C
Cable structure 1
1. LS0H outer jacket
2. Aramid yarns 2
3. Central tight buffer Tube 3
600/900 µm with colored
fibers 250 µm
TRUE
COLORS
Configuration
ZIP Applications
Dimensions Max. installation ÆÆ Distribution systems cable
Crush
Version Fiber qty nominal tension
[N/10 cm] ÆÆ Patchcords and pigtails
± 5% [mm] (ε=0.5 %) [N]
ÆÆ Terminals connection
2F 2 1.6 x 3.3 200 500
2F 2 1.8 x 3.7 300 500
2F 2 2.0 x 4.1 400 500
2F 2 2.8 x 5.7 600 1000 Structure and composition
30 G.652
G.657A1
MM 50/125 OM3 MM 50/125 OM4 G.657A2/B2
Violet 10
Aqua RAL 6027 7.5 5 G.657B3
RGB 196, 97, 140 2.5 G.657B3 Plus
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-10°C
-40°C
-100
Cable structure
1
1. FRLSOH outer jacket
2. Fibreglass yarns
3. Colored fibers 250 μm 3
TRUE
COLORS
Configuration
DC-T40 Applications
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Fibreglass yarn as stain relief elements
Code ÆÆ Optical fiber
ÆÆ Flame retardant LSOH outer sheath
Color red green blue yellow white grey brown violet aqua black orange pink
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Operating temperature
Fiber
+100
Code
Color* red green blue yellow white grey brown violet brown natural orange pink +50°C
temperature [°C]
+30°C
*Fiber with black mark to identify fibers 13-24
OPERTATION
TRANSPORT
INSTALATION
0°C
-25°C
-100
1 2 3
Cable structure
1. Outer jacket LS0H UV stabilized
2. Tight tubes 900 µm (LS0H)
with colored fibers 250 µm
3. Aramid yarns
TRUE
COLORS
Configuration
LDC Applications
Nominal Max. tensile load [N] ÆÆ Indoor/outdoor installations
Tight buffers Ø Crush
Version weight LS0H
[pcs] ± 5% [mm] installation operation [N/10 cm] ÆÆ Distribution networks in multifamily buildings
± 5% [kg/km]
ÆÆ FTTD Connections
2F 2 4.5 21
ÆÆ Distribution systems
4F 4 5.0 26 ÆÆ Fully dielectric
500 125
6F 6 5.5 30 ÆÆ LAN and FTTX network
8F 8 5.5 35 ÆÆ ODF connection
500 ÆÆ Datacenter distribution
10F 10 6.5 40
12F 12 6.5 45 700 175
16F 16 7.0 50
24F 24 8.0 65 1000 250 Features
Other fiber counts available on demand ÆÆ Compact design
ÆÆ Lightweight
Jacket colors ÆÆ Flexible
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers & Buffers ÆÆ Easy to strip
ÆÆ Fully dielectric
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Reduced diameter
Fiber ÆÆ Direct connectorization
Buffer
Fiber +55°C
temperature [°C]
INSTALLATION
OPERATION
Code
TRANSPORT
Color red green blue yellow white grey brown violet aqua natural orange pink
250 µm -5°C
Color* dark -10°C
red green blue yellow white grey brown violet brown orange pink
600/900 µm green
-100
1 1
Cable structure
2
1. Outer jacket LS0H fibers 3
2
3
UV stabilized 3. Aramid yarns
2. Subcables 1.8 mm 4. Central FRP strength
with tight tubes member
4
900 µm (LS0H) with 5. Ripcord
250 µm colored
TRUE
5
COLORS
LBR Applications
Ø Nominal weight Max. tensile load [N] ÆÆ Indoor/outdoor installations
Crush
Version Fiber qty ± 5% LS0H ± 5%
installation operation [N/10 cm] ÆÆ Distribution networks in multifamily buildings
[mm] [kg/km]
ÆÆ FTTD Connections
4F 4 6.5 48 750 250
ÆÆ Distribution systems
6F 6 7.5 63 1200 400 ÆÆ Fully dielectric
8F 8 8.7 85 1500 500 ÆÆ LAN and FTTX network
12F 12 10.9 131 1500 500 2000 ÆÆ ODF connection
ÆÆ Datacenter distribution
16F 16 11.3 119 1700 550
18F 18 11.3 131 1700 550
24F 24 13.0 179 2000 660
Features
PE Black RAL9005 LSOH Grey RAL7022 LSOH Light Grey Operating temper ature
RAL7037
+100
+70°C
Outer jacket color options:
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
SM G.652D SM G657A1, A2, A3 MM 50/125 OM2 MM 50/125 OM3 MM 50/125 OM4
RAL 1021 RAL 9010 RAL 2003 RAL6027 RAL4003 -40°C
-100
Cable structure 1
1. LS0H sheath
2. Glass yarns 2
3. Loose tube (PBT)
4. Optical fibers
3
5. Thixotropic filling compound
6. Ripcord 4
5
Datacom Compact LS0H Basic Rodent
design Protection
Configuration 6
Exo-FU
Ø ± 5%
Nominal weight Max. tensile load [N] Crush
Applications
Version Fiber qty LS0H ± 5%
[mm] installation operation [N/10 cm]
[kg/km] ÆÆ Fully dielectric cable
1T x 2-12F 2-12 6.8 48 ÆÆ Basic rodent protection
1100 550 1600
(ε=0.4%) (ε=0.25%) ÆÆ LAN and FTTX networks
1T x 14-24F 14-24 6.8 49
ÆÆ Distribution network
ÆÆ ODF connections
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Features
Code
ÆÆ Fiberglass strength element
Color red green blue yellow white grey brown violet aqua black orange pink ÆÆ Optical fibers
13-24 13 14 15 16 17 18 19 20 21 22 23 24 ÆÆ Loose tube with filling compound
ÆÆ Loose tube (PBT)
Fiber
ÆÆ Fiberglass as water absorbent and strain relief
element
Code
ÆÆ LS0H outer jacket
Color* red green blue yellow white grey brown violet brown natural orange pink
+100
Jacket colors Fiber identification +70°C
+60°C
Standard +50°C
temperature [°C]
OPERATION
TRANSPORT
13
INSTALLATION
24 14
1
2
23 15
22 16
21 17
-10°C
20
19
18
-20°C
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
-40°C
Optional
-100
SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL6027 RAL4003
Cable structure 1
1. LS0H sheath
2. Glass yarns 2
3. Loose tube (PBT)
4. Optical fibers
3
5. Thixotropic filling compound
6. Ripcord 4
5
Datacom Compact LS0H Basic Rodent
design Protection
6
Configuration
Exo-FU Applications
Nominal weight Max. tensile load [N] ÆÆ Fully dielectric cable
Ø ± 5% Crush
Version Fiber qty LS0H ± 5%
[mm] installation operation [N/10 cm] ÆÆ Basic rodent protection
[kg/km]
ÆÆ LAN and FTTX networks
1T x 2-12F 2-12 7.1 54
2000 1000 1600 ÆÆ Distribution network
(ε=0.4%) (ε=0.25%)
1T x 14-24F 14-24 7.1 55 ÆÆ ODF connections
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Central loose tubes (PBT Ø 3.0mm) with thixo-
Code tropic filing compound
ÆÆ Glass yarns as strain relief and water absorbent
Color red green blue yellow white grey brown violet aqua black orange pink
ÆÆ Polyester ripcord
13-24 13 14 15 16 17 18 19 20 21 22 23 24 ÆÆ UV stabilized LSOH sheath (different colors
available)
Code
Color red green blue yellow white grey brown violet aqua natural orange pink
Operating temperature
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
+100
+70°C
Jacket colors Fiber identification +60°C
+50°C
temperature [°C]
Standard
INSTALLATION
OPERATION
TRANSPORT
13
24 14
1
2
23 15
-10°C
22 16
-20°C
21 17
20 18
19
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037 -40°C
-100
Optional
SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL6027 RAL4003
Cable structure 1
Exo-GU
Fibers Ø ± 5%
Nominal weight Max. tensile load [N] Crush
Applications
Version Fiber qty LS0H ± 5%
per tube [mm] installation operation [N/10 cm]
[kg/km] ÆÆ Fully dielectric cable
1T x 2F 2 2 5.8 34 ÆÆ Basic rodent protection
ÆÆ LAN and FTTX networks
1T x 4F 4 4 5.8 34
ÆÆ Distribution network
1T x 6F 6 6 5.8 35
1200 ÆÆ ODF connections
1T x 8F 8 8 5.8 35 (ε=0,33%)
400 1500
1T x 12F 12 12 5.8 35 1500
(ε=0,5%)
1T x 16F 16 16 5.8 35
1T x 18F 18 18 5.8 36 Features
1T x 24F 24 24 5.8 36 ÆÆ Central loose tube (PBT) with filling compound
ÆÆ Optical fibers
ÆÆ Fiberglass as water absorbent and strain relief
Available colors element
ÆÆ LS0H outer jacket
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code Operating temperature
Color red green blue yellow white grey brown violet aqua black orange pink +100
13-24 13 14 15 16 17 18 19 20 21 22 23 24 +70°C
Code +55°C
temperature [°C]
Color red green blue yellow white grey brown violet aqua natural orange pink
INSTALLATION
OPERATION
TRANSPORT
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
-5°C
Standard
24
13
14 -100
1
2
23 15
22 16
21 17
20 18
19
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003
Cable structure 1
Exo-G0
Nominal Max. tensile load [N] Applications
Fibers
Fiber Ø ± 5% weight LS0H Crush
Version per ÆÆ Fully dielectric cable
qty [mm] ± 5% installation operation [N/10 cm]
tube
[kg/km] ÆÆ Basic rodent protection
ÆÆ LAN and FTTX networks
1T x 2F 2 2 5.9 37
ÆÆ Distribution network
1T x 4F 4 4 5.9 37
ÆÆ ODF connections
1T x 6F 6 6 5.9 37
1500
1T x 8F 8 8 5.9 37 (ε=0,33%)
500 1500
1T x 12F 12 12 5.9 38 2200
(ε=0,5%)
1T x 16F 16 16 5.9 38 Features
INSTALLATION
OPERATION
TRANSPORT
Color red green blue yellow white grey brown violet aqua natural orange pink
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm; -5°C
-20°C
Jacket colors Fiber identification
Standard
24
13
14
-100
1
2
23 15
22 16
21 17
20 18
19
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
Optional
SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003
Cable structure 1
Configuration
Exo-GI Applications
Code
INSTALLATION
OPERATION
TRANSPORT
Color red green blue yellow white grey brown violet aqua natural orange pink
-5°C
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm;
-20°C
Standard -100
13
24 14
1
2
23 15
22 16
21 17
20 18
19
PE Black RAL 9005 LSOH Grey RAL 7022 LSOH Light Grey RAL 7037
SM G.652D RAL 1021 SM G657 A1, A2, A3 MM 50/1025 OM2 MM 50/1025 OM3 MM 50/1025 OM4
RAL 9010 RAL 2003 RAL 6027 RAL 4003 fiber optic cables 2017 | 33
datacom bdc-MSA DATACOM BDC-MSA
Cable structure
1
1. LS0H outer jacket 6. Loose tubes (PBT) 2
2. Water-blocking with colored fibers
fiberglass yarns in filling gel 4
3. Water blocking yarns 7. Fillers
4. PET tape 8. Ripcord 5
3
5. Central strength
6
member (FRP) 7
BDC-msa Applications
4T x 12F 48 12 6 4 8.2 53 68 1500 550 ÆÆ Loose tube with filling compound (PBT Ø 1.8 mm)
ÆÆ Dry yarns to prevent moisture into the cable
5T x 12F 60 12 6 5 8.2 54 69 1500 550
ÆÆ Fiberglass as water absorbent and strain relief
6T x 12F 72 12 6 6 8.2 54 69 1500 550 element
8T x 12F 96 12 8 8 9.3 71 86 1620 750 ÆÆ UV stabilized LS0H jacket
Operating temperature
Available colors
+100
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers +70°C
1-12 1 2 3 4 5 6 7 8 9 10 11 12 +55°C
temperature [°C]
INSTALLATION
Code
OPERATION
TRANSPORT
Color red green blue yellow white grey brown violet aqua black orange pink
-5°C
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Tubes -20°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
-40°C
Code
-100
Color red green blue yellow white grey brown violet aqua black orange pink
*In case of lower fiber count some tubes can be replaced by fillers.
EASY TO
BEND TERMINATE
RESISTANCE
LSOH
SAFE COVER
SMALL SAFE
DIMENSIONS DAILY USE
ftth VC-d20 FTTH VC-D20
1
2
Cable structure 3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Configuration
VC-d20 Applications
60
ÆÆ Aramid strength element
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
0.03dB
0.03dB
0.03dB
Bend radius [mm]
15
10 Operating temperature
7,5
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1
2
Cable structure 3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Configuration
VC-d30 Applications
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
0.03dB
0.03dB
0.03dB
Bend radius [mm]
10
Operating temperature
7,5
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1
Cable structure
2
1. LS0H outer jacket 3
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Configuration
Applications
VC-d40
No. of fibers 1-2F 900 µm ÆÆ Optical cable with aramid yarns reinforcement
ÆÆ Customer connection
Outer diam [mm] 4.0
ÆÆ Fully dielectric cable
Tensile load perm/inst. [N] 150/400 ÆÆ Last mile connection
Weight [kg/km] 15 ÆÆ LAN and FTTX networks
Min. bend radius [mm] 10-60 mm* ÆÆ Distribution network
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
40
ÆÆ Optical 900 µm semi tight tube
0.03dB
0.03dB
0.03dB
0.03dB
Bend radius [mm]
10
Operating temperature
7,5
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
Cable structure
1. LS0H outer jacket 3 2 1
(white/ivory/black)
2. FRP rod
3. 250 µm optical fibers
Configuration
VC-dCY Applications
No. of fibers 1-4F 900 µm ÆÆ FTTH drop cable reinforced with FRP rods
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
40 ÆÆ FRP rods
0.03dB
0.03dB
0.03dB
0.03dB
Bend radius [mm]
10
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
-30°C
-100
1
Cable structure 2
3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Resibend®
Configuration
G.657B3
Max. change in attenuation [dB] Features
Fiber bending radius [mm]
1550 nm 1625 nm
ÆÆ Aramid yarns as strain relief
5 0.10 0.25 ÆÆ Optical fiber in 900 µm semi tight buffer
7.5 0.05 0.15 ÆÆ LS0H outer jacket (various colors available)
ÆÆ G.657B3 optical fibers
10 0.03 0.10
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1
Cable structure 2
3
1. LS0H outer jacket
2. Aramid yarns
3. 900 µm central semi tight buffer
tube with 250 µm colored fiber
Resibend Plus®
Configuration
G.657B3+
Max. change in attenuation [dB] Features
Fiber bending radius [mm]
1550 nm 1625 nm
ÆÆ Aramid yarns as strain relief
2.5 0.20 0.30 ÆÆ Optical fiber in 900 µm semi tight buffer
5 0.10 0.20 ÆÆ LS0H outer jacket (various colors available)
ÆÆ G.657B3+ optical fibers
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®
Configuration
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
40
0.03dB
0.03dB
0.03dB
0.03dB
Features
Bend radius [mm]
30
15
ÆÆ Aramid strength element
ÆÆ Optical fibers (up to 4 pcs) inside 900 µm
10
Easy Section Module®
7,5 ÆÆ LS0H outer jacket
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®
Last mile
Last mile connection
LS0H outdoor
Flexible Bendsafe Easy to FTTH Bendsafe
connection terminate
outdoor
Configuration
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
40
0.03dB
0.03dB
0.03dB
0.03dB
Features
Bend radius [mm]
30
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
1 3 2
Cable structure
1. LS0H outer jacket
2. Aramid yarns
3. Optical fibers (250 µm) in
Easy Section Module®
Configuration
60
0.15dB 0.05dB
0.30dB 0.10dB
1.00dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
0.30dB 0.20dB
0.50dB 0.20dB
1.50dB 0.50dB
0.10dB 0.03dB
0.20dB 0.10dB
1.00dB 0.25dB
1.00dB 0.25dB
40
Features
0.03dB
0.03dB
0.03dB
0.03dB
Bend radius [mm]
30
ÆÆ Aramid strength element
15
ÆÆ Optical fibers (up to 4 pcs) inside 900 µm
10 Easy Section Module®
7,5 ÆÆ LS0H outer jacket
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
Cable structure 1
1. LS0H outer jacket 2
2. Aramid yarns
3. 250 µm optical fibers 3
TRUE
COLORS
Configuration
DC-PRIM Applications
Outer diameter [mm] 3.0 3.5 ÆÆ Customer connection, fully dielectric cable
ÆÆ MTP/MPO termination cable
Tensile load perm/inst. [N] 350/150 350/150
ÆÆ LAN and FTTX networks
Weight [kg/km] 8 9
ÆÆ Distribution network
Min. bend radius [mm] 45 (depends on fiber type) 50 (depends on fiber type) ÆÆ Inside house OLT connection
Min. bend radius [mm] 150 ÆÆ Data Center connections cable
Available colors
D-DATACOM (aCCORDING TO DIN VDE 0888 & IEC 60304) - Fibers
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Aramid strength element
Fiber ÆÆ 250 µm optical fibers (12-24)
Color red green blue yellow white grey brown violet aqua black orange pink ÆÆ LS0H outer jacket
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Code +100
Color* red green blue yellow white grey brown violet brown natural orange pink +70°C
+55°C
*Fiber with black mark to identify fibers 13-24
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-5°C
-20°C
-40°C
-100
Cable structure
1. LS0H outer jacket 1
2. Dielectric strength members
3. 900 µm semi tight buffer (LS0H)
2
with colored 250 µm optical fiber
Configuration
EAC-Ras Applications
Max. ÆÆ Distribution cable
Nominal tensile
Ø ÆÆ For laying in risers
weight load [N] Crush
Version Fibers Buffers ± 5% ÆÆ FTTH feeder
±5% [N/10 cm]
[mm]
[kg/km] ÆÆ Easy access and installation
installation
8F 8 8 8.7 68 400
12F 12 12 8.7 72 400
1000 Features
16F 16 16 12.0 98 600
24F 24 24 12.0 106 600 ÆÆ FRP strength members inside cable jacket
ÆÆ Optical fibers in bundles
Other fiber counts available on demand
ÆÆ 2-24 elements in cable
Available colors ÆÆ LS0H UV resistant outer jacket (ivory by default,
various colors available)
F-FTTH (according to DIN VDE 0888 & IEC 60304)
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Operating temperature
Fiber
+100
Buffer
+70°C
Color red blue green yellow violet white orange grey brown black aqua pink +55°C
250 µm
temperature [°C]
INSTALLATION
OPERATION
Color
TRANSPORT
600/900 µm
red blue green yellow violet white orange grey brown black aqua pink
13-24 13 14 15 16 17 18 19 20 21 22 23 24 -5°C
-20°C
Fiber
-40°C
Code
Color red blue green yellow violet white orange grey brown black aqua pink
250 µm -100
Color* dark
red blue green yellow violet white orange grey brown aqua pink
600/900 µm green
Fiber extraction up to 25 m
*Buffer with black mark to identifiy fibers 13-24
Fiber extraction
3
Last mile LS0H Flexible Bendsafe Easy to FTTH
connection terminate
outdoor
Configuration
Last mile
connection outdoor
EAC-RAm
Max. tensile load
Nominal [N]
Easy Section Ø ± 5% Crush
Version Fibers weight ±10%
Modules [mm] ε=0.6% Δ α≤ 0.1 dB, [N/10 cm] Applications
[kg/km]
reversible
ÆÆ Distribution cable
2F Easy Section Modules
ÆÆ For laying in risers
12-18 6-9 8,7 69 400
500 ÆÆ FTTH feeder
20-30 10-15 9,5 79 400 ÆÆ Easy access and installation
32-48 16-24 12,0 106 600
4F Easy Section Modules
16-36 4-9 8,7 70 400
Features
40-48 10-12 9,5 78 400 500
ÆÆ FRP strength members inside cable jacket
52-60 13-15 10,5 85 400
ÆÆ Optical fibers in bundles
64-96 16-24 12,0 110 600
ÆÆ 2-24 elements in cable
6F Easy Section Modules ÆÆ LS0H UV resistant outer jacket (ivory by default,
12-24 2-4 8,7 70 400 various color available)
OPERATION
TRANSPORT
Color 250 µm red blue green yellow violet white orange grey brown black aqua pink
Fiber extraction up to 25 m
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Module
Color red blue green yellow violet white orange grey brown black aqua pink
Fiber extraction
13-24 13 14 15 16 17 18 19 20 21 22 23 24
Module
dark
Color* red blue green yellow violet white orange grey brown aqua pink
green
Cable structure
2
1. PP/HDPE outer jacket 4 3
2. Aramid yarns
3. Central loose tube (PBT)
with 250 µm colored fibers
in filling gel
4. Dielectric strength members
in the jacket
Configuration
DAC-BURRY Applications
Nominal Max. tensile load [N] ÆÆ Optical access cable with aramid yarns reinforce-
Ø
Fibers weight PE Crush ment
Version Fibers ± 5%
per tube ± 5% [N/10 cm]
[mm] installation operation ÆÆ Direct buried design
[kg/km]
ÆÆ Fully dielectric cable
1T x 2F 2 2 6.2 32
ÆÆ Last mile connection
1T x 4F 4 4 6.2 32 ÆÆ High crush resistance (3.5kN)
1Tx 6F 6 6 6.2 32 650 250 3500 ÆÆ Installation into existing ducts or direct buried
1T x 8F 8 8 6.2 32
1T x 12F 12 12 6.2 32
Features
Available colors
ÆÆ Central loose tube (PBT) with filling compound
T-Telecom (according to IEC 60304) - Fibers in tube ÆÆ Up to 12 optical fibers (250 µm)
1-12 1 2 3 4 5 6 7 8 9 10 11 12 ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ Embedded FRP strength members
Code
ÆÆ Highly resistant outer jacket made of hard polyole-
fin material, UV resistant
Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
-15°C
-40°C
-100
1
Cable structure
2
1. Outer jacket
4 3
2. Fiberglass yarns
3. Central loose tube (PBT)
with 250 µm colored fibers
in filling gel
4. Embedded strength members (FRP)
Configuration
DAC-BURRY-G Applications
Nominal Max. tensile load [N] ÆÆ Optical access cable with glass yarns reinforce-
Ø
Total Fibers weight PE Crush ment
Version ± 5%
fibers per tube ± 5% [N/10 cm]
[mm] installation operation ÆÆ Direct buried design
[kg/km]
ÆÆ Fully dielectric cable
1T x 2-12F 2-12 2-12 6.0 29
450 150 3500 ÆÆ Last mile connection
1T x 14-24F 14-24 14-24 6.5 35 ÆÆ High crush resistance (3.5kN)
ÆÆ Installation into existing ducts or direct buried
Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
1-12 1 2 3 4 5 6 7 8 9 10 11 12 Features
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
-15°C
-40°C
-100
Cable structure
1 2 3
1. HDPE UV resistant outer jacket
2. Aramid yarns
5
3. Inner LS0H jacket
4. FRP rods
4
5. Module with optical fibers
6. Ripcords
TRUE 6
COLORS
Configuration
VC-t601-PE Applications
Features
sag: 0.7 m
ÆÆ Aramid yarns as strength and water absorbent
elements
Ice load: max 5 mm ÆÆ Tight buffer or modules with optical fibers
span: 50 m ÆÆ ITU-T G.657A2 optical fiber(s)
ÆÆ Embedded strength members (FRP)
ÆÆ Highly resistant outer jacket made of HDPE
material
sag: 0.5 m
ÆÆ UV stabilized
ÆÆ Flexible internal LSZH subcable
Operating temperature
+100
+70°C
+55°C
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
-15°C
-25°C
-40°C
-100
Cable structure 1 2 3
1. HDPE UV resistant outer jacket
2. Aramid yarns
5
3. Inner LS0H jacket
4. FRP rods 4
5. Module with optical fibers
TRUE
COLORS
Configuration
VC-t60 Applications
sag: 0.8 m
Operating temperature
INSTALLATION
OPERATION
TRANSPORT
sag: 0.4 m
-5°C
-20°C
-40°C
-100
OPTIMAL
DIAMETER
HIGH BLOWING
RANGE
HIGH FIBERS
DENSITY
LOW FRICTION
COEFFICIENT
UNIT DESIGN
microduct MK-AX2 MICRODUCT MK-AX2
1
Cable structure
1. Polymeric jacket with low coefficient
of friction
2. 250 µm colored fibers 2
Configuration
OPERATION
TRANSPORT
12/10 12 10 12/8 12 8 -
14/12 14 12 14/10 14 10 -
-15°C
Fiber qty 2-12 Fiber qty 2-12 -30°C
-40°C
Available colors
-100
1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT) 5. Water blocking yarns
5
with colored fibers in 6. Water blocking yarns
filling gel on strand element
3. Fillers 7. Ripcord 6
4. Central strength
member (FRP)
7
Optimal Low Telecom Blowing Microduct
diameter friction installation Generation 1
Configuration
INSTALLATION
12/10 12 10 12/8 12 8
OPERATION
TRANSPORT
14/12 14 12 - 14/10 14 10
Fiber qty 4-24 Fiber qty 4-24 -15°C
-30°C
-40°C
Available colors
T-Telecom (according to IEC 60304) - Fibers T-Telecom (according to IEC 60304) - Tubes
-100
1-12 1 2 3 4 Tube 1 2 3 4 5 6
Code Code
Color red green blue white Color red green blue white violet orange
3 1
Cable structure 2
1. Outer sheath: HDPE 4
2. Loose tubes (PBT) with optical
fibers 5
3. Filling compound
4. Central strength member (FRP) 6
5. Water swellable yarns on FRP
6. Water swellable yarns on S-Z
stranded cable core 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
Operating temperature
+100
+70°C
+60°C
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
+100
+70°C
-15°C
+55°C
temperature [°C]
-30°C
INSTALLATION
TRANSPORT
OPERATION
-40°C
-100
-30°C
-100
1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT)
5
with colored fibers in filling gel
3. Fillers
4. Central strength member (FRP) 6
5. Water blocking yarns on FRP
6. Water blocking yarns on strand
element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
INSTALLATION
8T x 10F 80 10 8 8 0 6.2 30
OPERATION
TRANSPORT
8T x 12F 96 12 8 8 0 6.2 31
+100
-15°C
+70°C
MetroJET MK-LXS8
+55°C
-30°C
Nominal Max. tensile
temperature [°C]
INSTALLATION
3 1 2
Cable structure
1. HDPE outer jacket 4
5
2. Loose tubes (PBT) with colored
fibers in filling gel 6
3. Fillers
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking tape on strand 7
element
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
INSTALLATION
OPERATION
TRANSPORT
-15°C
-30°C
-40°C
-100
1
2
Cable structure 3
1. HDPE outer jacket 4
2. Loose tubes (PBT) with colored
5
fibers in filling gel
3. Fillers
4. Central strength member (FRP) 6
5. Water blocking yarns on FRP
6. Water blocking yarns
on strand element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
INSTALLATION
OPERATION
1-12 1 2 3 4 5 6 7 8 9 10 11 12
-15°C
Code
-30°C
Color red green blue white violet orange grey yellow brown pink black aqua -40°C
Code
*In case of lower fiber count some tubes can be replaced by fillers.
1
3 2
Cable structure
1. HDPE outer jacket 4
2. Loose tubes (PBT) with colored
fibers in filling gel 5
3. Fillers 6
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking yarns on strand
element 7
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
Color red green blue white violet orange grey yellow brown pink black aqua * - blowing range may be lower
INSTALLATION
OPERATION
TRANSPORT
*In case of lower fiber count some tubes can be replaced by fillers.
-15°C
-30°C
-40°C
-100
1
3
Cable structure 2
1. HDPE outer jacket 4
Configuration
INSTALLATION
OPERATION
Color
TRANSPORT
red green blue white violet orange grey yellow brown pink black aqua
Tube 1 2 3 4 5 6 7 8 9 10 11 12 -30°C
-40°C
Code
Color red green blue white violet orange grey yellow brown pink black aqua -100
*In case of lower fiber count some tubes can be replaced by fillers.
3 1 2
Cable structure
1. HDPE outer jacket 4
5
2. Loose tubes (PBT) with colored
fibers in filling gel 6
3. Fillers
4. Central strength member (FRP)
5. Water blocking yarns on FRP
6. Water blocking yarns on strand 7
element
Optimal Low Telecom Blowing Microduct 7. Ripcord
diameter friction installation Generation 1
Configuration
Color red green blue white violet orange grey yellow brown pink black aqua Operating temperature
Code
INSTALLATION
OPERATION
TRANSPORT
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer -15°C
**In case of lower fiber count some tubes can be replaced by fillers
-30°C
-40°C
-100
1
3
Cable structure
1. HDPE outer jacket 4
2
2. Fillers
3. Loose tubes (PBT)
with colored fibers 5
in filling gel 6
4. Central strength member
(FRP)
5. Water blocking yarns on FRP 7
Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
T-Telecom (according to IEC 60304) - Tubes
+100
Tube 1 2 3 4 5 6 7 8 9 10 11 12 +70°C
+55°C
Code
temperature [°C]
INSTALLATION
OPERATION
TRANSPORT
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -15°C
-30°C
-40°C
-100
1 2
Cable structure
3
1. HDPE outer jacket
2. Fiberglass yarns
3. PET tape 7
4. Water blocking yarns on FRP 4
5
5. Central strength member
(FRP) 6
6. Loose tubes (PBT) with colored
fibers in filling gel 8
Telecom Duct Basic 7. Fillers
Rodent 8. Ripcord
Protection
Configuration
INSTALLATION
OPERATION
Code
Color red green blue white violet orange grey yellow brown pink black aqua
Code
Color red green blue white violet orange grey yellow brown pink black aqua
*In case of lower fiber count some tubes can be replaced by fillers.
1
2
Cable structure
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection
Configuration
Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers Ø load [N]
Total Active weight Crush ÆÆ Fully dielectric cable
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Basic rodent protection
lation tion
20-24T x 12F 240-288 12 24 20-24 14.2 156 2800 1000 ÆÆ Optical fibers
ÆÆ Fibreglass yarns as tensile elements
Other fiber counts available on demand
ÆÆ UV stabilized HDPE jacket
Available colors
T-Telecom (according to IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink black aqua
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
Code
-40°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -100
Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection
Configuration
INSTALLATION
Available colors
TRANSPORT
OPERATION
Code
-40°C
Color red green blue white violet orange grey yellow brown pink black aqua
-100
t-telecom (according to IEC 60304) - Tubes
Tube 1 2 3 4 5 6 7 8 9 10 11 12
Code
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection
Configuration
INSTALLATION
Available colors
T-Telecom (according to IEC 60304) - Fibers -100
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code
Color red green blue white violet orange grey yellow brown pink black aqua
Code
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
4100 1800
INSTALLATION
TRANSPORT
Code
Color red green blue white violet orange grey yellow brown pink black aqua
Code
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
Cable structure 1
2
5
1. HDPE outer jacket 6. Loose tubes (PBT)
2. Water blocking fiberglass with colored fibers 3
4
yarns in filling gel
7
3. Water blocking yarns 7. Fillers
4. Water blocking tape 8. Ripcord
5. Central strength 6
member (FRP)
8
Telecom Duct Basic
Rodent
Protection
Configuration
Code
Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]
INSTALLATION
Code
TRANSPORT
OPERATION
Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C
-100
1
2
Cable structure 3
1. PE sheath 7. Loose tubes (PBT)
2. Glass yarns 8. Optical fibers 6 4
3. Filling compound 9. Ripcord
4. Water swellable yarns 5
5. Water swellable tape
6. Central strength member
7
(FRP)
Configuration
Nominal Max. tensile load ÆÆ For installation into existing duct or directly buried
Fibers Ø [N]
Total Active weight Crush ÆÆ Fully dielectric cable
Version Fibers per ± 5%
elements tubes ±10% instal- opera- [N/10 cm]
tube [mm] [kg/km] ÆÆ Basic rodent protection
lation tion
TRANSPORT
OPERATION
Tube 1 2 3 4 5 6 7 8 9 10 11 12
Code -15°C
Color red green blue white violet orange grey yellow brown pink black aqua
-40°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-100
1 2
Cable structure
3
1. HDPE outer jacket 7
4
2. Fiberglass yarns
3. HDPE inner jacket 5
4. Water blocking yarns
5. Central strength member (FRP)
6. Loose tubes (PBT) 6
with colored fibers in filling gel
7. Fillers
Telecom High Duct Direct 8. Ripcords
Rodent buried
Protection 8
Configuration
Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
+70°C
t-telecom (according to IEC 60304) - Tubes +55°C
temperature [°C]
Tube 1 2 3 4 5 6 7 8 9 10 11 12
INSTALLATION
TRANSPORT
OPERATION
Code
Color red green blue white violet orange grey yellow brown pink black aqua -15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers -40°C
-100
1 2
Cable structure
3
1. HDPE outer jacket 6. Loose tubes (PBT) 7
4
2. Fiberglass yarns with colored fibers
3. HDPE inner jacket in filling gel 5
4. Water blocking 7. Fillers
yarns 8. Ripcords
5. Central strength 6
member (FRP)
Configuration
16T x 12F 192 12 16 16 15.9 185 4600 2200 ÆÆ Loose tube with filling compound (PBT Ø 2.0 mm)
ÆÆ Dry yarns and tape to prevent moisture into the
18T x 12F 216 12 18 18 15.9 187 4600 2200 cable
24T x 12F 288 12 24 24 17.6 193 5000 2600 ÆÆ Glass yarns as tensile elements
Other fiber counts available on demand ÆÆ Double HDPE jacket
ÆÆ LS0H, PA etc. outer jacket option
Available colors
T-Telecom (according to IEC 60304) - Fibers Operating temperature
1-12 1 2 3 4 5 6 7 8 9 10 11 12
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink black aqua
temperature [°C]
INSTALLATION
TRANSPORT
OPERATION
Code
-40°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
-100
**In case of lower fiber count some tubes can be replaced by fillers
1
2
Cable structure
1. PE outer jacket (black)
2. Water blocking and strength 3
elements
3. FRP rods incorporated in outer
jacket
4. Optical fibers 4
5
5. LS0H module
6. Ripcord
6
14.2
18M x 12F 216 12 18 18 140 2500 1200
OPERATION
INSTALLATION
TRANSPORT
(max 14.7)
15.2
24M x 12F 288 12 24 24 140 2700 1300
(max 15.7) -5°C
Other fiber counts available on demand -30°C
-40°C
Available colors
T-Telecom (according to IEC 60304) - Fibers
-100
1-12 1 2 3 4 5 6 7 8 9 10 11 12
Code
Color red green blue white violet orange grey yellow brown pink black aqua
Code
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
1
Cable structure 2
3
1. LSOH sheath 7
4
2. Corrugated steel tape
3. Fiberglass yarns 5
4. Water swellable yarns and tape
5. Central strength member (FRP)
6. Loose tube with optical fibers 6
in filling compound
7. Fillers
Telecom High Duct Direct 8. Ripcord
Rodent buried
Protection 8
Configuration
Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements modules ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed
Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]
INSTALLATION
Code
TRANSPORT
OPERATION
Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C
-100
1 2 3
Cable structure
1. PE sheath
2. Corrugated steel tape
3. Fiberglass yarns 4
4. Loose tube (PBT) with optical
fibers in filling compound
5. Ripcord
5
Configuration
Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements tubes ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed
Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
t-telecom (according to IEC 60304) - Tubes
+100
Tube 1 2 3 4 5 6 7 8 9 10 11 12
+70°C
Code +55°C
temperature [°C]
INSTALLATION
Color red green blue white violet orange grey yellow brown pink black aqua
TRANSPORT
OPERATION
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-15°C
-40°C
-100
1 2 3
Cable structure
1. PE sheath (black) / option: LSOH (grey)
2. Corrugated steel tape
3. Fiberglass yarns
4
4. Loose tube (PBT) with optical
fibers in filling compound
5. Ripcord
5
Configuration
Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements tubes ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed
Code
Operating temperature
Color red green blue white violet orange grey yellow brown pink black aqua
+100
t-telecom (according to IEC 60304) - Tubes +70°C
+55°C
Tube 1 2 3 4 5 6 7 8 9 10 11 12
temperature [°C]
INSTALLATION
TRANSPORT
Code
OPERATION
Color red green blue white violet orange grey yellow brown pink black aqua
-15°C
*In cable with a multi-layer construction color of the tubes will be repeated in second layer
**In case of lower fiber count some tubes can be replaced by fillers
-40°C
-100
1
2
Cable structure
7 3
1. PE jacket 4
2. Corrugated steel tape
3. Fiberglass yarns 5
4. Water swellable yarns and tape
5. Central strength member (FRP)
6. Loose tube (PBT) with optical 6
fibers in filling compound
7. Fillers
Telecom Rodent Duct Direct 8. Ripcords
Protection buried
High 8
Configuration
Nominal Max. tensile ÆÆ For installation into existing duct or directly buried
Fibers load [N]
Total Active Ø weight Crush ÆÆ Extreme rodent protection
Version Fibers per
elements modules ± 0.3 ±10% al- [N/10 cm]
tube [kg/km] static
lowed
Color red green blue white violet orange grey yellow brown pink black aqua +100
+70°C
+55°C
t-telecom (according to IEC 60304) - Tubes
temperature [°C]
INSTALLATION
Tube 1 2 3 4 5 6 7 8 9 10 11 12
TRANSPORT
OPERATION
Code
-15°C
Color red green blue white violet orange grey yellow brown pink black aqua
*In cable with a multi-layer construction color of the tubes will be repeated in second layer -40°C
**In case of lower fiber count some tubes can be replaced by fillers
-100
Cable structure 1 2 3
Configuration
AERO-DR03
Nominal Tensile load [N]
Fibers Ø
Total Active weight Crush
Version Fibers per
elements tubes
± 5%
±10% [N/10 cm] Applications
tube [mm] allowed static
[kg/km]
ÆÆ For installation on poles
1F 1 1 1 1 3.0 9.5 300 100 3 3000000
ÆÆ Fully dielectric
Other fiber counts available on demand ÆÆ Aerial cable with aramid reinforcement
Available colors
T-Telecom (according to IEC 60304) - Fibers in tube
Features
1-12 1 2 3 4 5 6 7 8 9 10 11 12
ÆÆ Semi tight buffer with 1 optical fiber (0.9 mm)
Code
ÆÆ Aramid yarns
Color red green blue white violet orange grey yellow brown pink black aqua ÆÆ LSOH outer sheath
13-24 13 14 15 16 17 18 19 20 21 22 23 24
INSTALLATION
OPERATION
TRANSPORT
-10°C
-40°C
Ice: 0 mm Wind: 94.4 km/h
span: 55 m
-100
sag: 1.1 m
sag: 0.8 m
sag: 0.6 m
1
Cable structure
2 5
1. PE jacket 4. Central loose tube (PBT) 4
3
Cable variants
Parameter
Color red green blue white violet orange grey yellow brown pink black aqua Operating temperature
13-24 13 14 15 16 17 18 19 20 21 22 23 24
+100
Code +70°C
+55°C
Color red green blue white violet orange grey yellow brown pink natural aqua
temperature [°C]
INSTALLATION
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
TRANSPORT
OPERATION
NESC Light
-15°C
span: 120 m
-40°C
sag: 2.4 m
-100
NESC Medium
span: 70 m
sag: 1.4 m
NESC Heavy
span: 40 m
sag: 0.8 m
1 2 3 4
Cable structure
1. PE sheath 4. Loose tube with filling
2. Ripcord compound
3. Water blocking yarns 5. FRP rods
reinforcement
5
Cable variants
Version AERO-DDF03
Parameter Features
Crush performance 5000 N
ÆÆ Loose tube with filling compound (PBT)
Bending performance 10 cycles [20 x D]
ÆÆ Up to 24 fibers in a cable
Water Penetration 3 m sample, 1 m head, 24 h ÆÆ Two FRP strength elements
ÆÆ Dry yarns to prevent moisture into cable
Available colors ÆÆ Ripcord yarns for easy jacket removal
T-Telecom (according to IEC 60304) - Fibers in tube ÆÆ PE UV resistant jacket
1-12 1 2 3 4 5 6 7 8 9 10 11 12
INSTALLATION
Color red green blue white violet orange grey yellow brown pink natural aqua
TRANSPORT
OPERATION
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
-15°C
NESC Light
-40°C
span: 135 m
-100
sag: 2.1 m
NESC Medium
span: 80 m
sag: 1.2 m
NESC Heavy
span: 45 m
sag: 0.7 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
NESC Light
span: 130 m
sag: 2.6 m
NESC Medium
span: 85 m
sag: 1.7 m
NESC Heavy
span: 45 m
sag: 0.9 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Color red green blue white violet orange grey yellow brown pink black aqua
Operating temperature
*In case of lower fiber count some tubes can be replaced by fillers.
+100
NESC Light +70°C
span: 190 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 3.8 m
-15°C
NESC Medium
-40°C
span: 130 m
-100
sag: 2.6 m
NESC Heavy
span: 75 m
sag: 1.5 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
NESC Light +70°C
span: 190 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 3.8 m
-15°C
NESC Medium
-40°C
span: 140 m
-100
sag: 2.8 m
NESC Heavy
span: 80 m
sag: 1.6 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
NESC Light +70°C
span: 250 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 5.0 m
-15°C
NESC Medium
-40°C
span: 170 m
-100
sag: 3.4 m
NESC Heavy
span: 95 m
sag: 1.9 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
APPLICATION AND CABLE SPAN CHARACTERISTIC (for 6 tubes construction) ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.5 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket
Operating temperature
+100
NESC Light +70°C
span: 250 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 5.0 m
-15°C
NESC Medium
-40°C
span: 170 m
-100
sag: 3.4 m
NESC Heavy
span: 95 m
sag: 1.9 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Other fiber counts available on demand ÆÆ FRP strength and anti-buckling element
ÆÆ Dry yarns to prevent moisture into the cable
ÆÆ Loose tube (PBT Ø 2.0 mm) with filing compound
ÆÆ 6-12 elements SZ stranded cable core
ÆÆ Optical fibers
ÆÆ Fillers (if applicable)
ÆÆ Water-swellable tape
ÆÆ Aramid yarns as strain relief and water absorbent
ÆÆ UV stabilized HDPE jacket
Operating temperature
+100
NESC Light +70°C
span: 360 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 7.2 m
-15°C
NESC Medium
-40°C
span: 250 m
-100
sag: 5.0 m
NESC Heavy
span: 140 m
sag: 2.8 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
NESC Light +70°C
span: 370 m +55°C
temperature [°C]
OPERATION
INSTALLATION
TRANSPORT
sag: 7.4 m
-15°C
NESC Medium
-40°C
span: 270 m
-100
sag: 5.4 m
NESC Heavy
span: 150 m
sag: 3.0 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
+70°C
+55°C
temperature [°C]
NESC Light
OPERATION
INSTALLATION
TRANSPORT
span: 530 m
-15°C
sag: 10.6 m
-40°C
NESC Medium
span: 400 m
-100
sag: 8.0 m
NESC Heavy
span: 230 m
sag: 4.6 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
+70°C
+55°C
temperature [°C]
NESC Light
OPERATION
INSTALLATION
TRANSPORT
span: 700 m
-15°C
sag: 14 m
-40°C
NESC Medium
span: 530 m
-100
sag: 10.6 m
NESC Heavy
span: 310 m
sag: 6.2 m
1
Cable structure 2
6
1. HDPE outer jacket 6. Fillers
3
2. Aramid yarns 7. Water blocking tape
4
3. Central strength 8. Ripcord
7
member (FRP)
4. Loose tubes (PBT)
with colored fibers in
filling gel 5
8
5. Water blocking yarns
Telecom Aerial FTTH
Configuration
Operating temperature
+100
+70°C
+55°C
temperature [°C]
NESC Light
OPERATION
INSTALLATION
TRANSPORT
span: 800 m
-15°C
sag: 16.0 m
-40°C
NESC Medium
span: 600 m
-100
sag: 12.0 m
NESC Heavy
span: 350 m
sag: 7.0 m
Cable structure
1. Outer jacket PE 5
2
2. Fiberglass yarns 3
Configuration
FTTA-DAC Applications
Ø Nominal Max. tensile load [N] ÆÆ Fiber to the antenna system ( FTTA)
Fibers per Crush
Version Fibers ± 5% weight
tube installation operation
[N/10 cm] ÆÆ Optical access cable with fiber glass yarns
[mm] ±10% [kg/km]
reinforcement
1T x 2F 2 2 5.8 31 ÆÆ Direct buried construction
1T x 4F 4 4 5.8 31 ÆÆ Fully dielectric cable
800
1T x 6F 6 6 5.8 31 (ε=0.33%) ÆÆ Last mile connection
250 3500
1T x 8F 8 8 5.8 32 1200
(ε=0.50%)
1T x 12F 12 12 5.8 32
1T x 24F 24 24 6.3 38
Features
Color red green blue white violet orange grey yellow brown pink black aqua
Code +100
+70°C
Color red green blue white violet orange grey yellow brown pink natural aqua
+50°C
temperature [°C]
*In 24-fiber tube construction colors will be repeated to facillitate identification, fibers 13-24 will have rings every 25 cm
OPERATION
INSTALLATION
TRANSPORT
-15°C
-45°C
-100
Configuration
+4x1.5 mm2
OPERATION
INSTALLATION
TRANSPORT
4T x 12F
48 12 8 4 12.1 191 2700 1300
+4x1.5 mm2
-40°C
Technical copper wire characteristics
Max DC resistance 12,1±0,2 Ω/km@20°C
-100
Electric strength 3400 V DC/1 minute
Configuration
OPERATION
INSTALLATION
TRANSPORT
-15°C
Technical copper wire characteristics
-40°C
Max DC resistance 36,0 Ω/km@20°C
Configuration
TRANSPORT
Configuration
+4x1.00 mm2
OPERATION
INSTALLATION
TRANSPORT
3T x 12F
36 12 8 3 12.1 144 2700 1300
+4x1.00 mm2
4T x 12F
48 12 8 4 12.1 145 2700 1300
+4x1.00 mm2 -15°C
Configuration
+4x1.5 mm2
OPERATION
INSTALLATION
TRANSPORT
Configuration
+4x2.5 mm2
OPERATION
INSTALLATION
TRANSPORT
1
Cable structure 2
3
1. HDPE outer jacket 5. Water blocking tape
2. Fiberglass yarns 6. Central strength 3
3. Loose tubes (PBT) member (FRP)
with colored fibers in 7. 2x Ø 0.8/1.3 5
4
filling gel insulated Cu pair
4. Water blocking yarns 8. Ripcord 6
on FRP
7 8
FTTH Duct Rodent Hybrid
Protection FO+Power
Basic
Configuration
OPERATION
INSTALLATION
TRANSPORT
FIBRAIN MÉXICO
www.fibrain.com