Energy Dispersive X-ray Fluorescence Spectrometer.
ARL QUANT’X EDXRF
Advantages The ARL QUANT’X is a versatile energy-dispersive X-ray fluorescence (EDXRF) bench top spectrometer. It allows non-destructive elemental analysis • F - U, ppm to % of solids, powders and liquids. EDXRF allows for analysis with little or no • Air, vacuum and helium sample preparation and covers concentrations from the lower ppm to 100%.
• Camera + small spot analysis
With the option to perform the analysis in air, vacuum or helium; optimal • UniQuant Standard-less results are always within reach. Several sample changer options, small spot FP analysis collimators, spinner or camera and an intuitive software with multi-language support add to the convenience of use.
Applications The optional UniQuant FP based standard-less quantification software fully
Forensics and Investigation, unlocks the capabilities of this spectrometer. Whatever the type of application – RoHS and WEEE Screening, industrial, environmental, research or educational – the ARL QUANT’X is cost- Oils, Lubricants and Wear Metals effective and the stand-alone analytical tool that every lab can depend on. Particulate Matter on Filter Media, Food and Consumer Safety, Cement, Alternative Fuels, Metallurgical Slags and Mining Ores, Gemology, Plastics and Polymers, Precious Metals and Catalyst ARL QUANT’X Technical Specifications EDXRF technique Direct excitation with primary beam filters Elemental range Fluorine to uranium Concentration range From ppm to % X-ray tube Rh or Ag anode; power: 50 W; maximum voltage: 50 kV 9-position automatic filter changer, 8 pre-installed filters to cover wide range of elements and Primary beam filters customizable conditions • Peltier cooled Silicon Drift Detector (no liquid nitrogen required) Detector • Typical resolution of ≤ 140 eV @ Mn Kα at 200 Kcps incoming count rate (ICR) Collimators Small spot analysis with 1 mm, 2 mm, 3.5 mm and 8.8 mm Sample observation CCD Camera, VGA resolution with indication of excitation spot Atmosphere Air, vacuum (optional) and helium (optional) Single sample: • Without spinner: any size sample • With spinner (optional): 31 mm to 47 mm 10-position sample tray (carousel) Sample presentation • Without spinner: 31 mm to 51.5 mm • With spinner (optional): 31 mm to 47 mm 20-position sample tray (carousel): Without spinner: 31 mm Special sample holders can accommodate smaller samples Large samples; max sample size: 30 cm (W) x 40 cm (D) x 5 cm (H) Option 1: up to 21.5 cm sample height Chamber extension Option 2: up to 37.0 cm sample height Line Voltage: 110-240 VAC, 50/60 Hz Spectrometer: 500 W max. Vacuum Pump: 1000 W max. Site/Utility requirements Ambient Temp: 10-30 °C (50-86 °F) Humidity: 20-80%, non-condensing Conditions: Indoor use only Width x Depth: 58 cm x 62 cm Height: 42.5 cm (closed) – 91.5 cm (door open) Dimensions, weight and Height w. extension chamber: 22.5 cm (closed) or 38 cm (closed) noise Weight: Typically around 80 kg (175 lbs) Noise level: < 45 dB in stand-by, 53 dB at full cooling Interlocks: Chamber lid, X-ray tube, detector, warning light, fail-safe circuit design Radiation: < 1 µSv/h (< 0.1 mR/hr) at a distance of 10 cm (4 in) Safety standards: Electrical and protection: EN IEC 61010-1 (Safety requirements for electrical equipment for measurement, control and laboratory use. – Part 1: General Radiation, electrical requirements). Radiation (fully protected system): Swiss directive ORaP RS 814.501. safety and compliance Electro-magnetic immunity: EN CEI 61326-1 (Electrical equipment for measurement, control and laboratory use – EMC requirements - Part 1: General Requirements European directives: • 2006/95/EC (LVD) Low Voltage Directive • 2011/65/EC (RoHS) Restriction of Hasardous Substances Directive • 2002/96/EC (WEEE) Waste Electrical and Electronic Equipment Directive Communication Instrument to PC Ethernet (2 ports), camera (USB). Optional support through modem connection. WinTrace 10 under Windows 10 Modern, comprehensive, intuitive and versatile interface with multi-language support Software Option TRACEcom: Results transmission to LIMS or external computer Option UniQuant: Advanced standardless fundamental parameters package
(The Nineteenth Century Series) Grace Moore - Dickens and Empire - Discourses of Class, Race and Colonialism in The Works of Charles Dickens-Routledge (2004) PDF