1P Arktite ® Heavy Duty Circuit Breaking NEMA 4 Watertight


Receptacle Assemblies and Housings
100 A, 600 VAC/250 VDC, 50**-400 hertz

Mating Mating
Receptacle Assembly Receptacle Plug Connector

Style 1 Receptacle Housings Only


Hub Spring Door Spring Door Threaded Cap Cable
Description Size Cat. # Cat. # Only Cat. # Dia. Cat. # Cat. #
2-wire, ⎫ 11⁄4 AREA10214 0.875 to 1.70 APJ10277 APR10257
AR1021 AR1027
2-pole ⎬⎭ 11⁄2 AREA10215

3-wire, ⎫ 11⁄4 AREA10314 0.875 to 1.70 APJ10377 APR10357


3-pole ⎬⎭
AR1031 AR1037
11⁄2 AREA10315
4-wire, ⎫ 11⁄2 AREA10415 0.875 to 1.70 APJ10477 APR10457
AR1041 AR1047
4-pole ⎬⎭ 2 AREA10416

Style 2 Style 2 Style 2


2-wire, ⎫ 11⁄4 AREA10324 0.875 to 1.70 APJ10387 APR10367
3-pole ⎬⎭
AR1032 AR1038
11⁄2 AREA10325

3-wire, ⎫ 11⁄2 AREA10425 0.875 to 1.70 APJ10487 APR10467


4-pole ⎬⎭
AR1042 AR1048
2 AREA10426

Dimensions
ARE Assembly AR Receptacle - Spring Door APJ Plug

No. Poles f No. Poles b c


2 or 3 9⁄32 3 6 9⁄16 3 3⁄4
4 13⁄32 4 6 5⁄8 4 1⁄8
AR Receptacle - Open and with cap APR Connector

No. Poles Housing c No. Poles b c


2 or 3 open 3 3⁄16 3 3 3⁄8 3 3⁄16
4 open 3 7⁄16 4 3 1⁄2 3 7⁄16
2 or 3 with cap 3 11⁄16
4 with cap 3 7⁄8
** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

976 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds

STIBOINFO((CRH:66008com:1P:976))
PDFINFO CH0 1 P - 1
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0966-2 Name: 1P-966 DATE: JAN 19 2006 Time: 6:04:24 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100

1P Arktite® Heavy Duty Circuit NEMA 4 Watertight


Breaking Plugs and Receptacles
Industrial Heavy Duty
Non-Hazardous Areas
illustrated here, is for conditions where it
Application: is desired to use the contact of the plug
Arktite circuit breaking plugs and receptacles sleeve with the detent spring to complete
are used: the grounding safety circuit. The extra
ɀ to supply power to portable electrically grounding conductor in the portable
operated devices such as motor-generator cable is connected to the plug sleeve by a
sets, compressors, heating and cooling units, pressure connector.)
welders, conveyors, lighting systems and Each plug contact fits closely the
similar equipment opening of its individual arcing chamber.
ɀ where temporary power is needed, such as Grounding contact is bonded to the
at trailers, building units, heavy machinery plug sleeve. Grounding contact is keyed
and similar equipment to its proper location to prevent
ɀ wherever electrical loads must be quickly mispolarization.
disconnected from power source Arktite connectors’ gasketing system
ɀ in a typical installation, where a large provides unsurpassed watertight integrity.
machine utilizes a number of electrical motor All-aluminum UNI-SHELL TM threaded
drives and for ease of adjustment, removal, construction provides added strength to
maintenance and replacement, each motor is withstand extreme physical abuse.
connected by portable cord and Arktite
receptacles rather than permanently wired
ɀ in areas where dust, dirt, moisture and
corrosion are a problem
NEW!
ɀ indoors and outdoors in non-hazardous
NEMA 4
areas of chemical plants, process industry
Rating
facilities, meat packing plants, manufacturing
plants and similar industrial locations
Features:
ɀ Circuit breaking: Plugs through 200 ampere
rating may be disconnected under load; 400
ampere units are for service disconnect use
only.
ɀ Receptacles accept only plugs of the same
amperage rating, style and number of poles, Arktite Style 2
making it impossible to mismate, and 60 ampere
provides for positive polarization.
ɀ Extra wide electrical spacing allows for
maximum safety.
ɀ Insulator materials are the result of intensive
testing. Selection has been made based on
highest dielectric strength, maximum
mechanical and impact resistance, lowest
moisture absorption and highest arc tracking
resistance.
ɀ A variety of installations is possible due to NEW!
the availability of several types of back boxes. Smaller
ɀ Designed to withstand rough usage and the Cable
effects of adverse environments. Range
ɀ Reversible interiors, 30, 60 and 100 ampere
(except 30 and 60 ampere, 5-pole) Arktite safety circuit under severe service.
plug and receptacle interiors are Grounding contact is no longer than the
interchangeable using a screwdriver. This others, so grounding circuit is made
makes it possible to feed a normally first and broken last.
deenergized receptacle from an energized The arc formed by pulling the plug is
plug with usual Arktite safety; no energized instantly snuffed in the deep, confined
contacts are exposed. insulated arcing chamber while the plug Arktite’s TRI-LOCK TM cable grip has
ɀ Additional features are indicated in the view contact is still a considerable distance three clamps that tighten around the
at right: inside. The arc cannot travel over to the cable to securely lock it in place, even
Grounding contact in Style 2 is bonded to other side of the circuit or to the when subjected to extreme flexing and
the receptacle housing. housing. jerking.
Easily wired interior assemblies in Detent spring forms a grounding The unique SURE-SEAL TM cable gland
receptacles and plugs. See table on page path from plug sleeve to receptacle provides a complete environmental seal
938 for type of contacts in units. housing. Arktite plugs and receptacles by distributing pressure equally around
Arktite Style 2, illustrated here, has an are made in two styles. With either style, the circumference of the cable.
extra grounding contact which forms a the portable appliance is grounded Wrenching surfaces make Arktite
parallel circuit with the circuit formed by the before it is energized and remains connector quick and easy to assemble.
plug sleeve and receptacle detent spring, grounded until after it is deenergized.
and assures continuity of the grounding (Arktite Style 1, not

966 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds

STIBOINFO((CRH:66008com:1P:966))
PDFINFO CH0 0 1 P - 2
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0967-29 Name: 1P-967 DATE: JAN 19 2006 Time: 6:05:30 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100

Arktite® Heavy Duty Circuit NEMA 4 Watertight 1P


Breaking Plugs and Receptacles
Industrial Heavy Duty Non-Hazardous Areas

Grounding: Style 1 vs. Style 2


Cooper Crouse-Hinds Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles.
NEC reference 250.138 (A) & (B).
Style 1 – Metallic STYLE 2 – Metallic Style 2 – Non-Metallic
A Style 1 plug is one in which the grounding A Style 2 metallic housing plug is one in In a Style 2 receptacle, the grounding
conductor in the flexible cable is bonded to which the grounding conductor in the flexible connection is made before line and load
the plug sleeve by a pressure connector. A cable is bonded to the extra (grounding) pole poles engage, and is broken after the line
Style 1 receptacle is one which is grounded and metal plug sleeve by a pressure load poles disengage. Furthermore, upon
by virtue of the fact that it is an integral part of connector. A Style 2 metallic housing insertion, the plug sleeve of metal shelled
a grounded conduit system. On insertion, the receptacle is one in which the extra units, makes contact with detent springs of
plug sleeve makes contact with detent (grounding) pole is electrically connected to the grounded receptacle housing before line
springs of the grounded receptacle housing the equipment grounding conductor and the and load poles engage, and on withdrawal,
before line and load poles engage, and on metal receptacle housing which itself is remains in contact until after line and load
withdrawal, remains in contact until after line grounded by virtue of the fact that it is an poles disengage. Therefore, exposed metal
and load poles disengage. Therefore, integral part of a grounded conduit system. In parts of the portable equipment or plug are
exposed metal parts of the portable Style 2, non-metallic housing plugs and suitably grounded.
equipment or plug are suitably grounded. receptacles, the extra pole is used for
grounding since the housings are non- Made of
conductive. non-metallic
Krydon
material

Metal
shelled
type

Style 1 Style 2
Ground conductor Ground conductor
attaches to shell. attaches to contact,
which is bonded to shell.

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 967

STIBOINFO((CRH:66008com:1P:967))
PDFINFO CH0 0 1 P - 3
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0968-18 Name: 1P-968 DATE: JAN 19 2006 Time: 6:05:35 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100

1P Arktite® Heavy Duty Circuit NEMA 4 Watertight


Breaking§ Plugs and Receptacles
Industrial Heavy Duty Non-Hazardous Areas

Options:
ɀ The following special options are available
from factory by adding suffix to Cat. No.:
Suffix to be
Added to Arktite receptacles have a cast
Cat. # Description raised rib located inside the
S22. . . . .Reversed contacts. Receptacle receptacle sleeve. The location of
assembled with plug interior the rib is in a specific relationship to
(exposed contacts), plug the receptacle insulator that houses
assembled with receptacle interior the contacts.
(recessed contacts). For
applications where plug is
energized to feed normally de-
energized receptacle. Available on
30 through 400 ampere units
NOTE: 30 (2, 3, 4-pole), 60 and 100
ampere interiors can be
interchanged in the field using a
screwdriver. Factory conversion is
required for 200 and 400 ampere
products.
S4. . . . . .Special polarity. For use where two
or more receptacles of the same
ampere rating, style and number of
poles are to be installed in the same
area for use on different voltages
and/or frequencies. Prevents
insertion of a plug in a receptacle
with different electrical rating. The mating plug has a cast groove
Available on 20 through 400 ampere located on the outside of the plug
units as follows: sleeve. This groove lines up with the
Receptacle interior rotated 221⁄2 raised rib.
degrees to right and plug changed
to match (See photo to right)

Standard Materials:
ɀ Metallic receptacle housings, plug and cord
connector bodies – high impact strength
copper-free aluminum
ɀ Nonmetallic receptacles, plugs and cord
connectors – Krydon® fiberglass-reinforced
polyester material
ɀ Back boxes: 20, 30, 60, 100 and 200 Accessories:
ampere – cast aluminum; 400 ampere – Accessories include a variety of angle adapters, panel adapters and back boxes for Arktite
Feraloy® iron alloy receptacles, listed on pages 990-993. Included throughout 1P are wire mesh cable grips and
ɀ Insulation (metallic products): (2-, 3-, and protective caps for Arktite plugs.
4-pole) 30, 60, 100, 200, 400 ampere –
fiberglass-reinforced polyester; 20, 30 Certifications and Compliances:
ampere (5-pole) – melamine ɀ UL Standards: 1682, 514; 1010 (APJ and NPJ plugs only)
ɀ Contacts: pressure, solder, binding screw – ɀ CSA Standard: C22.2 No. 182.1
brass; crimp/solder – leaded red brass; 20,
30, 60, 100 ampere – telurium copper; 200,
400 ampere Typical installation

Standard Finishes:
ɀ Feraloy—electrogalvanized and aluminum
acrylic paint
ɀ Aluminum – natural
ɀ Krydon fiberglass-reinforced polyester
material – grey
ɀ Fiberglass-reinforced polyester insulation –
(red)
ɀ Melamine – natural (brown)
ɀ Brass – natural
ɀ Leaded red brass – electro-tin-plate
§ 400A rated units are for service disconnect use only.

968 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds

STIBOINFO((CRH:66008com:1P:968))
PDFINFO CH0 0 1 P - 4
2: 5: 50: 95: 98: 100:
SYS19: BASE2 JOB: CRMAIN06-0995-2 Name: 1P-995 DATE: JAN 19 2006 Time: 6:07:14 PM Operator: RB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 Zoom: 100

AR Arktite® Circuit Breaking Round Flange Weatherproof 1P


Receptacle Housings for Panel Mounting With
Threaded Cap
30/60/100/200 A, 600 VAC/250 VDC, AP and APJ Plugs

Recept. Cable Plug Dimensions


Amps Style‡ Description Cat. # Dia. Cat. #
1
3-wire,
3-pole
*
} AR6337 0.60 to 1.20 APJ3375

30
4-wire,
4-pole
*
} AR6347 0.60 to 1.20 APJ3475

}
2 3-wire, *
AR6348 0.60 to 1.20 APJ3485
4-pole

1
3-wire,
3-pole }* AR6637 0.75 to 1.45 APJ6375

60
4-wire,
4-pole }* AR6647 0.75 to 1.45 APJ6475
2 3-wire,
4-pole }* AR6648 0.75 to 1.45 APJ6485

1
3-wire,
3-pole }* AR61037 1.00 to 1.70 APJ10377

100
4-wire,
4-pole }* AR61047 1.00 to 1.70 APJ10477 AR Round Flange Receptacles
}*
2 3-wire, Description a b c d e f
AR61048 1.00 to 1.70 APJ10487
4-pole 30 amp. 2 12-24 43⁄4 27⁄16 15⁄8 21⁄4
⎧ .875 to 1.375 2, 3, 4-pole

200
1
3-wire,
3-pole } AR62031ɍ ⎨
⎩ 1.875 to 2.500
AP20355
AP20358
60 amp.
2, 3-pole
2 12-24 43⁄4 213⁄16 17⁄8 33⁄8

⎧ .875 to 1.375
}
2-wire, AP20365 60 amp. 2 12-24 43⁄4 31⁄8 17⁄8 33⁄8
2 AR62032ɍ ⎨ 4-pole
3-pole ⎩ 1.875 to 2.500 AP20368
100 amp. 2 12-24 43⁄4 31⁄16 17⁄8 49⁄16
2, 3-pole
‡ Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. 100 amp. 2 12-24 43⁄4 35⁄16 17⁄8 49⁄16
ɍ 200 ampere size is provided with clamp cover. 4-pole
* Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 200 amp. 33⁄8 3⁄8-16 73⁄4 43⁄16 27⁄8 51⁄8
and 4-pole 30 ampere, 3 and 4-pole 60 and 100 ampere. For details, see table on page 969. To 3-pole
specify, add the suffix ‘‘T’’ to the catalog number. For example:
APJ3375-T (Plug) AR6337-T (Receptacle)
AP 200A Plugs

APJ 30, 60 and 100A Plugs

No.
Amps Poles a b c
30 2, 3 or 4 61⁄2 413⁄16 215⁄16
60 2 or 3 81⁄2 53⁄4 35⁄8
60 4 81⁄2 513⁄16 33⁄4
100 2 or 3 101⁄8 69⁄16 33⁄4
100 4 101⁄8 65⁄8 41⁄8
200 3 143⁄4 1011⁄16 63⁄4

† These dimensions are approximate and vary with cable size.

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2006 Cooper Crouse-Hinds 995