Sei sulla pagina 1di 10

Current Value

Parameter
NSN
InactivityTimerDownlinkDCH8-32: 5
InactivityTimerUplinkDCH8-32: 5
DCH to FACH Transition Time InactivityTimerDownlinkDCH64-384: 2
InactivityTimerUplinkDCH8-32: 2

UL_DL_activation_timer: 2
FACH to PCH Transition time ExtendedULDLactivationTmr: 0
PCH to Idle state transition time MSActivitySupervision: 29
TrafVolTimeToTriggerUL: 0 s
FACH to DCH Transition Time TrafVolTimeToTriggerDL: 0 s

Trigger FACH to DCH TrafVolThresholdULLow: 7 (1 KB)


TrafVolThresholdDLLow: 7 (1 KB)
HSDPA to FACH trigger time MACdflowthroughputTimetoTrigger: 5
HSDPA to FACH trigger throughput MACdflowthroughputRelThr: 0 bps
T3212 (Peridic Location Update) CS_T3212: 2
QqualMin QqualMin : -18
QrxLevMin QrxLevMin : -115
Max Bit Rate HSPA/MAC-D Flow MaxBitRateNRTMACDFlow: No Limit
Max Bit Rate DL PS MaxBitRateDLPSNRT: 128
Max Bit Rate UL PS MaxBitRateULPSNRT: 128
T313 T313 : 3
N313 N313 : 50
T300 T300 : 2
N300 N300 : 3
UE Tx Power on PRACH UEtxPowerMaxPRACH: 24
T314 T314 : 6
Current Value
Ericsson Huawei ZTE

hsdschInactivityTimerCpc For CPC


Capable : 5 , hsdschInactivityTimer BeD2FStateTransTimer=5 TRbRecfgCmpDtoF : 15
Non_CPC Capable : 2

- BeF2PStateTransTimer=2

InactivityTimerPCH : 30 PSInactTmr= 5
T312Connected : 1
- BEF2DTVMTIMETOTRIG=0 N312Connected : 1

- BEF2DTVMTHD=1024

- BEH2FTVMTIMETOTRIG=5
- BEH2FTVMTHD=64
T3212 : 4 T3212=4 T3212Cs : 4
QqualMin : -18 QqualMin=-18 QqualMin : -18
QrxLevMin : -115 QrxLevMin=-115 QrxLevMin : -115
- - HsMaxDlRateDch : No Limit
- R99MaxDlRateDch : 128
- R99MaxUlRateDch : 128
T313 : 3 T313=3 T313 : 3
N313 : 100 N313=20 N313 : 50
- T300=2 T3002 : 2
- N300=3 N300 : 3
- MaxUlTxPowerforint=24 MaxRACHTxPwr : 24
T314 : 12 T314=6 T314 : 4
Recommend Value Unit
5

2
s
As per vendor minute
0
s
1000
Bytes
5 s
64 Bytes
4 Hours
-18 dB
-115 dBm
No Limit
128 Kbps
128 Kbps
3 S
20 Times
2 S
3 Times
24 dBm
6 s
Remark

If > 4 hours will be change to 4 hours, if below still remain


Parameter
NSN

msTxPwrMaxGSM : 33
msTxPwrMaxGSM1x00 : 43
gprsMsTxpwrMaxCCH : 33
Ms Tx Power Max gprsMsTxPwrMaxCCH1x00 : 43

RxLev Access Min rxLevAccessMin => GSM : 105, DCS : 95


TA Max msMaxDistInCallSetup : 255
BS Tx Power max (attenuation) bsTxPwrMax, bsTxPwrMax1x00 : 0
AFR Radio Link Timeout radioLinkTimeoutAmr : 44
AHR Radio Link Timeout radioLinkTimeoutAmrHr : 44

Radio Link Timeout radioLinkTimeout => GSM : 36, DCS : 32


Max Number of Retransmission maxNumberRetransmission : 2
Number of Multiframes noOfMFramesBetweenPaging : 2
Number of Slots Spread Trans nbrOfSlotsSpreadTrans : 32
Periodic Ms Location Update(2G/3G) timerPeriodicUpdateMs : 2 h

Sacch repeat window sacchRepeatWindow : 4

T200S T200S : 300 ms

T200F T200F : 200 ms


Max Queue Length timeLimitCall : 10
T3101 T3101 : 3

T8 T8 : 12
T7 T7 : 20
T3103 T3103 : 6
T3107 T3107 : 6

Time Limit Handover timeLimitHandover : 5


Current Calue
Ericsson Huawei

MSTXPWR GSM: 33 MSTXPWR GSM: 33


DCS: 30 DCS: 30

ACCMIN => GSM : 102 , DCS : 95 ACCMIN => GSM : 102 , DCS : 95
MAXTA => Normal cell : 64 , XrangeCell : 255 MAXTA => Normal cell : 64
- -
RLINKTAFR (44) & RLINKUPAFR (48) AFR RLT:56
RLINKTAHR (44) & RLINKUPAHR (48) AHR RLT:56

RLINKT for Downlink (GSM : 36 , DCS :32) , RLINKUP for


Uplink (GSM : 40 , DCS : 36) RLT : 52
MAXRET : 2 IMMASSMAXSENDNUM = 2
MFRMS : 2 BSPAMFRAMS=2
TX : 32 TX : 32
T3212 : 40 (Unit : decihour in Ericsson) T3212 : 40 (Unit : decihour in Huawei)

SACCH/T N200 : 5 times N200SACCH : 5

Parameter T200 in Ericsson related to parameter SIGDEL


, if SIGDEL= NORMAL (T200=240ms) then SIGDEL=LONG
(T200=1400ms) T200S:200

Parameter T200 in Ericsson related to parameter SIGDEL


, if SIGDEL= NORMAL (T200=240ms) then SIGDEL=LONG
(T200=1400ms) T200F:200
- TIQUEUINGTIMER=8
15-30 (unit in deciseconds) T3101=3
T8 in Ater Signalling => 8 second , T8 in A-interface : 25
second T8=10
- T7=10
- T3103=10
- T3107=10

HANDOVER_ REQUEST_timer (THNDREQ) => 8 second ,


HANDOVER_ REJECT_timer (THNDRQREJ) => 1 second TQHO=8
Recommend Value Unit
ZTE

MsTxPwrMax : 33
DCS : 30
GSM: 33
DCS: 30 dBm
RxLevAccessMin : -100 GSM: -105 dBm
DCS: -95 dBm dBm
TaMax : No Limit No Limit
- 0 dB
BsRadioLkTmOutAMRFR : 44 44 Sacch_times
BsRadioLkTmOutAMRHR : 44 44 Sacch_times

BsRadioLKTmOut, MsRadioLKTmOut
=> GSM: 36; DCS: 32
36 Sacch_times
MaxRetrans : 4 2 times
BsPaMframs : 5 2 Number
TxInteger : 14 32 Number
T3212 : 360 4 Hours
(RepeatACCH = YES) -> SACCH repeat
Hardcoded 4 times

T200_0, T200_5 : 5
240 ms

T200_1, T200_2 : 5
200 ms
rmsT11 : 6 7 s
RmsT3101 : 3 3 s
RmsT8 : 1
As per vendor s
RmsT7 : 1.5 As per vendor s
RmsT3103 : 6 As per vendor s
RmsT3107 : 6 As per vendor s

RmsTqho : 5
6 s
Remarks

Before new year, all non blocking GSM cells in East Area already
modified to -105

ZTE only has BS Tx Power Min

If > 4 hours will be change to 4 hours, if below still remain

Need confirm why ZTE value too small

Need confirm why ZTE value too small

Never been adjusted


Never been adjusted
Never been adjusted
Never been adjusted
Current Value
Parameter Unit
NSN ZTE
T300 2 2
N300 3 3
T312 Idle
N312 Idle
T312 Connected
N312 Connected
T302
N302
T304
N304
T305
T307
T308
N308
T309
T313 3 3
N313 50 50
T314 6 4
T315
N315
T316
T317
T3212Cs
ATTIndCs
NMOPs
Kcs
Kps
0 TCH
3 SDCCH
4 BCH
8 SDCCH+CBCH
14 PDTCH
6 CCH

Potrebbero piacerti anche