2 ��� 17-005 Base plate and anchor design.nb
�����������
�����������������
As a base of a lattice tower leg, we have considered only axial loads and shear at the base. Jarlso
standard tower “feet” are always central to the foundation column.
�������
Pu = required axial compressive strength, N
Pt = required axial tensil strength, N
A1 = area of base plate, mm2
A2 = maximum area of the portion of the supporting surface
that is geometrically similar to and concentric with the loaded area, mm2
As a conservative approach and Design Guide recommendation we have considered
A1 and A2 equal. However, Jarlsø standard solutions have always greater column area, approx.
A2 > 2.5 A1
ϕ = strength reduction factor for bearing, 0.65 per Section 9.3, ACI 318 - 05
N
(f ')c = specified compressive strength of concrete,
mm2
N = base plate length, mm
W = base plate width, mm
bf = column flange width, mm
d = overall column depth, mm
n' = yield - line theory cantilever distance from column web or column flange, mm
N
FEXX = filler metal classification strength,
mm2
17-005 Base plate and anchor design.nb ��� 3
<< Units`
�����������������������
myTowers = {"RTB15m"};
Material properties
Pu = {333 000} N;
Pt = {315 000} N;
f 'c = 25 N mm ^ 2;
fy = 345 N mm ^ 2;
fyre = 420 N mm ^ 2;
FEXX = 345 N mm ^ 2;
ϕ = 0.65;
The minimum base plate area can be determined by the following equation
Pu
A1 (req) =
ϕ * 0.85 * f 'c
24 108.6 mm2
bf = {100} mm;
d = bf ;
Δ = N0.95 * d - 0.8 * bf 2
{7.5 mm}
{162.769 mm}
Since all the tower legs are equal angles the length shall be equal to width
Nreq = Wreq ;
Check the tower base plate
17-005 Base plate and anchor design.nb ��� 5
{PASS}
Nprov = Wprov ;
6 ��� 17-005 Base plate and anchor design.nb
�������������������������������������������
Nprov - 0.95 * d
mprov =
2
{152.5 mm}
Wprov - 0.85 * bf
nprov =
2
{157.5 mm}
A1 = Wprov ^ 2
160 000 mm2
Pp = 0.85 * f 'c * A1
3.4 × 106 N
4 d * bf Pu
X=
d + bf ^ 2 ϕ * Pp
{0.150679}
2 X
λ= /. x_ /; x > 1 → 1
1+ 1-X
{0.404014}
Simplify d * bf , mm > 0
λn ' = λ
4
{10.1003 mm}
2 Pu
tmin = lmax
ϕ * fy * Nprov * Wprov
{21.4581 mm}
{PASS}
17-005 Base plate and anchor design.nb ��� 7
������������
�������
Check the welding of the column to the base plate.
Since there are anchor bolts outside the flanges of the angle, the forces can be assumed to be
distributed onto the both full legs of the angle. Conservatively the thickness and radius of the angle
will not be applied.
Fillet weld will be applied to both sides of the main leg + to the stiffeners as lengthen the legs of the
angle and 2 perpendicular (see drawing above) as min. 100mm in length.
Maximum welding load:
{1156 mm}
Pt
maxload = N
beff
272.491 N
mm
weld = 6 mm;
Rn = Fnw weld
1611.25 N
mm
Where
1.5
Fnw = 0.6 * FEXX * 1.0 + 0.5 * SinPi 4
268.541 N
mm2
{PASS}
8 ��� 17-005 Base plate and anchor design.nb
�����������������
The anchors installed in the column, thus the brake out strength is limited by the column cross
section. See image below.
The anchor load is transferred to the vertical reinforcing steel in the column. The required area of
steel has been designed as part of the foundation design.
kc = 10;
f 'c 1.5
Nb = kc hef mm *N
N mm2
{165 386. N}
Eccentricity factor
ψecN = 1.0;
17-005 Base plate and anchor design.nb ��� 9
Since the anchors are located less than 1.5 hef from three or more edges, the value of hef as per
below
1
hef = Max /@ Transposeca,max / 1.5, ca,min mm mm
3
{222. mm}
ANco = 9 * hef ^ 2
443 556. mm2
ca,min
feDn[x_] := IfThreadca,min / mm < 1.5 hef mm, 0.7 + 0.3 , 1
1.5 hef
ca,min
ψedN = feDn /@ 0.7 + 0.3
1.5 hef
{0.93964}
Cracking factor, assumed that the region of analysis where the anchors are placed is cracked
ψcN = 1.0;
Modification factor for post-installed anchors.
10 ��� 17-005 Base plate and anchor design.nb
ψcpN = 1.0;
ANc
ϕNcbg = ϕ ψecN ψedN ψcN ψcpN Nb
ANco
{81 983.8 N}
Thus, it is necessary to transfer the anchor load to the vertical reinforcing steel in the column.
Required area of steel:
Pt
Areq =
0.9 * fyre
833.333 mm2
ψe = 1.0;
ψt = 1.0;
ψs = 1.0;
λ = 1.0;
nre = {12};
Below the necessary development length for the rebars without hooks. Necessary vertical length
ld cumputed as below
fyre ψt ψe ψs λ
ld = dre1
1.1 f 'c N
2.5
mm2
{366.545 mm}
Where
cb + Ktr * (mm)
Thread > 2.5
dre1
{True}
Atr * fyre
Ktr = mm N
10 * s * n
{51.7439}
Atr = Ndre1 ^ 2 * Pi 4 * 5
565.487 mm2
dre2 = 10 mm;
17-005 Base plate and anchor design.nb ��� 11
cb = 50 mm;
s = 153 mm;
n = 3;
The column reinforcement are located at the edge of the column (see drawing above). Using a
Class B splice factor with 1.3 the necessary minimum development length le as below:
Pt * 1.3 * ld
le =
nre * dre1 ^ 2 * Pi 4 * 0.9 * fyre
{292.588 mm}
ca,max - 50 mm
ldeff = lanch mm - 200 - 50 - 65 mm -
1.5
{246.333 mm}
False
�������
The following are the summarized results for all the checks above
num = 1;
brkOutCheckFormatted =
Table[If[TrueQ[brkOutCheck[[i]]], Style[brkOutCheck[[i]], Green],
Style[brkOutCheck[[i]], Gray, Italic]], {i, 1, num}]
{False }
devLengthCheckFormatted =
Table[If[StringMatchQ[devLengthCheck[[i]], "PASS"], Style[
devLengthCheck[[i]], Green], Style[devLengthCheck[[i]], Red]], {i, 1, num}]
������������� ������ �� ���� �� ������� �������� �� �������� � �� ������������[������ ����]�
{If[StringMatchQ[False, PASS],
Style[devLengthCheck〚i〛, Green], Style[devLengthCheck〚i〛, Red]]}
sum = TableForm[
{bf , Pu , Pt , Wprov , tprov , ca,min , ca,max , smax , ANc , nre , dre1 , thCheckFormatted,
weldCheckFormatted, brkOutCheckFormatted, devLengthCheckFormatted},
TableHeadings → {{"Main leg size", "Compression",
"Tension", "Base plate size", "Base plate thickness",
"anchor min. edge distance", "anchor max. edge distance",
"max. anchor distance", "Column size", "No. of vertical rebars",
"Diameter of reinforcement", "Thickness check", "Welding check",
"Brakeout cone check", "Developement length check"}, myTowers}]
17-005 Base plate and anchor design.nb ��� 13
RTB15m
Main leg size 100 mm
Compression 333 000 N
Tension 315 000 N
Base plate size 400 mm
Base plate thickness 30 mm
anchor min. edge distance 266 mm
anchor max. edge distance 333 mm
max. anchor distance 142 mm
Column size 360 000 mm2
No. of vertical rebars 12
Diameter of reinforcement 12 mm
Thickness check PASS
Welding check PASS
Brakeout cone check False
Developement length check If[StringMatchQ[False, PASS], Style[devLengthCheck〚i〛
14 ��� 17-005 Base plate and anchor design.nb
��������������������
ACI 318 M -
(1)
05 Building Code Requirements For Structural Concrete And Commentary
AISC Steel Design Guide - Base Plate and Anchor Rod Design. Second Edition. (2)