Sei sulla pagina 1di 6

RADAR

Pre-Survey Checklist

Station Satcom Pte Ltd,


30 Cecil Street,
#19-08
Prudential Tower,
Singapore
049712
1

RADAR Pre-Quotation/Installation Questionnaire

The successful installation and accurate quotation for a Radar relies upon the accurate provision of
information relating to navigation equipment fitted (or to be fitted) in the vessel concerned.
To assist in this initial process the following details are requested: -

I- GENERAL / VESSEL DETAILS


Vessel name / Hull no. MOGRA / 201 /- Owner LMCS MARITIME
/ Project no.

Shipyard TSU WORKS,NKK Contact person


CORPORATION,JAPAN.
Vessel type CRUDE OIL TANKER Phone no.
Note A
Gross tonnage 78845 Email
Date of Keel Laid 13-12-1999
Delivery date 26-06-2000 Delivery Address for the Equipment
Length / Beam 274.2/48.0 MTR
IMO no. 9191723
Class. Society IRS/LR
Flag INDIAN Time/Port of Delivery
Vessel Scheduled next 1) CHENNAI
3 ports including the 2) FUJAIRAH FOR BUNKERS
delivery port 3) LOAD PORT TBN Agency Details

II-POWER REQUIREMENTS
Emergency Generator Yes [ X ] NO [ ] Is a UPS Required Yes [ X ] NO [ ]
Vessels 230V [ X ] Spare Breaker
main/emergency available at the Yes [ ] NO [ ]
110V [ ]
voltage Emergency Power
Distribution Panel
Note A : Vessels with GT =>10,000 T , should have a CAT-I ( 23” Display ) Radar as per IMO requirements

III-NAVIGATION EQUIPMENT
Station Satcom Pte Ltd,
30 Cecil Street,
#19-08 Prudential Tower,
Singapore
2

1 D/GPS #1
Make JRC
Model JRC/ JLR-7700
Is Signal connected to old Radar Yes [ X ] NO [ ]
If No is a NMEA Buffer available with Yes [ ] NO [ ]
spare output?
2 D/GPS #2
Make JRC
Model JRC/ JLR-7700
Is Signal connected to old Radar Yes [ X ] NO [ ]
If No is a NMEA Buffer available with Yes [ ] NO [ ]
spare output?
3 Gyro Compass
Make TOKIMEC
Model TOKIMEC/ TG-6000
Is Signal connected to old Radar Yes [ X ] NO [ ]
If analogue Gyro, is any converter Yes [ ] NO [ ]
with spare outputs available? Gyro Converter needed [ ]
4 Speed Log
Make JRC
Model JRC/JLN 202 & JRC/ JWW-5
Is Signal connected to old Radar Yes [ X ] NO [ ]
If PPM analogue signal, is any Yes [ ] NO [ ]
converter with spare outputs Speed log to NMEA converter is needed [ ]
available?
5 AIS
Make FURNO
Model FURNO/ FA-150
Is Signal connected to old Radar Yes [ ] NO [ X ]
If NO is a Spare output available or a Spare O/P [ ] NMEA Buffer needed [ ]
NMEA Buffer is needed?
6 Echo Sounder “ Optional for MFD “
Make JRC
Model JRC/JFE-380
Is a NMEA output available? Yes [ ] NO [ ]
7 Anemometer“ Optional for MFD “
Make TYPE – B,NIPPON ELECTRIC INSTRUMENT
Model
Is a NMEA output available? Yes [ ] NO [ ]
8 ECDIS“ Optional “
Make JRC
Model JRC/ JAN-901B
Is Old Radar Connected to ECDIS Yes [ X ] NO [ ]
If Yes , Type of connection : Radar Over Lay [ X ] ARPA Targets[ ]
9 VDR

Station Satcom Pte Ltd,


30 Cecil Street,
#19-08 Prudential Tower,
Singapore
3

Make RUTTER
Model RUTTER, VDR-100G3
Is Old Radar Connected to VDR Yes [ ] NO [ ]
If Yes , Type of connection : VGA [ ] DVI [ ] 5-BNC [ ] Special Connector [ ]
Is any additional interface kit/cables Yes [ ] NO [ ]
will be required?
10 Other Radar Onboard
Make
Model
Is Old Radar inters witched to the Yes [ ] NO [ ]
other Radar

IV- RADAR MOUNTING VERSION REQUIRED


RADAR version required I) Standalone Pedestal version [ ]
II) Console kit version [ ]
For Standalone Pedestal Is the location of the old Pedestal can accommodate the new one [ ]
Will a new mounting base will be needed or old one can be used [ ]
Can existing cable penetration used for the new cables [ ]
For Console kit Is the display cut-out suitable for the new display [ ]
Any adapting plate will be required to cover the gaps around the display[ ]
Is there a sufficient space for installation of the Radar Processor [ ]

V- SCANNER MOUNTING
Are old scanners mounted on Main Mast [ X ] Individual Mast [ ]
A- Height of the handrail and could it obstruct the B
array movement. [ 100 ]
B- Distance from mid of the current pedestal to the
Main mast and could it obstruct the array A
movement. [ 150 ]

VI-Location of Equipment
Photos, Sketches & Plans are important as they give much better overview than a long text.
a) Sketch

Station Satcom Pte Ltd,


30 Cecil Street,
#19-08 Prudential Tower,
Singapore
4

Kindly locate on the below grid the proposed location for the Radar as well as location of equipment listed in III

b) Photos
Kindly provide photos for the following:
1. Full Bridge view from Starboard Side.
2. Full Bridge view from Port Side.
3. Proposed location for the Radar Display.
4. Proposed location for the Radar Scanner.
5. General photos for the equipment listed in III.
6. Suggested cable penetrations for various signals.
7. Head Panels needed to be opened.
8. Suggested cables routes especially for the Scanner cables.

c) Plans :
Estimated Distances between the following:
From Radar Display Proposed Location to Emergency Power Distribution Panel 2.2 m.
D/GPS#1 Buffer 2.2 m.
D/GPS#2 Buffer 2.2 m.
Gyro Signal Distribution 5.2 m.
AIS Distribution box AIS fitted top of the X- band
radar display
Speed Log 5.20 m.

Station Satcom Pte Ltd,


30 Cecil Street,
#19-08 Prudential Tower,
Singapore
5

Echo Sounder 2.10 m.


Anemometer 1.0 m.
ECDIS 0.19 m.
VDR 5.20 m.
RADAR #2 1.0 m.

Notes:
Vessel has two RADAR
1. X band (with ARPA) –JMA-9253-7CA
2. S band (without ARPA) – JMA 9303

Station Satcom Pte Ltd,


30 Cecil Street,
#19-08 Prudential Tower,
Singapore

Potrebbero piacerti anche