Technical data
Technical data
2
www.krone-filter.com
Operating instructions
The comprehensive instructions accompanying the filter must be followed!
The filter is installed in pipes using flanges. Ensure that the pipes). Before using with a medium other than the medium
standard version of the filter is installed vertically or horizon- specified in the design, or for different operating data, the
tally in a mechanically stress-free manner without additional resistance of the materials of the parts and seals touched by
loads. The medium must flow in the direction specified on the pressure-bearing membrane to the medium to be filtered
the housing. Incorrect installation can cause filter malfunc- must be checked by the customer; it may be necessary to
tions. If the contaminant drain pipe is laid with an ascending consult with the manufacturer and to execute a conformity
gradient ensure that the inlet pressure of the filter is at least evaluation in accordance with PED EN 2014/68/EU (if there
a 0.3 bar higher than the counter pressure in the contami- is a CE-mark requirement).
nant drain pipe (pay attention to the loss through friction in
3
www.krone-filter.com
psi
0.35
5
0.25
0.15
Pressure loss in bar
0.12
–65
1.5
Pressure loss
0
0
DN 0
0
0
0
50
80
30
10
15
20
25
35
40
45
50
60
0.09
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
0.07
00
1.2
1.0
0.05
70
80
DN
DN
DN
0.03
0.4
0.02
0.01
5 10 20 50 100 200 500 1.000 l/s
Dimensioning example (0.2 mm filtration degree) / selection chart at 500 m3/h, the use of a DN 250 or DN 300 is recommended at 200 µm.
4
www.krone-filter.com
Technical data
B
D2 Backflushoutlet
G
D1
F
Flanges in accordance with EN 1092-1 A Outlet
PN 10–16 or ANSI 16.5 150 lbs C
D
E Space for insert removal
(adjustable)
DN DN mm mm mm mm mm mm mm approx. kg m3/h m3 m3
SS316Ti / SS316L / 50 25 310 385 520 1.020 1.100 200 135 25 8–45 0.04 0.03
steel ** 65 25 310 385 520 1.020 1.100 200 135 30 8–45 0.05 0.03
80 40 405 510 620 1.100 1.200 235 190 35 15–80 0.08 0.05
100 40 430 480 680 1.305 1.400 240 240 40 40–120 0.12 0.08
150 40 490 680 810 1.450 1.550 260 255 80 50–300 0.26 0.17
200 80 590 790 1.010 1.950 2.050 290 280 110 100–500 0.42 0.27
250 100 740 980 1.250 2.180 2.280 345 330 165 160–800 0.96 0.60
300 100 890 1.155 1.440 2.510 2.610 375 385 200 200–1.100 1.50 0.94
350 100 950 1.260 1.481 2.467 2.500 410 410 300 300–1.500 2.80 1.71
400 100 1.010 1.325 1.535 3.010 3.100 485 465 450 400–2.000 3.70 2.20
500 150 1.590 2205 2.350 3.800 3.900 695 555 1.600 800–3.000 6.50 3.87
600 200 1.540 3055 3.490 4.650 4.750 780 805 2.300 1.200–4.000 8.10 4.83
700 200 2.650 3255 3.750 5.650 5.750 800 900 2.800 1.500–5.000 12.60 7.39
800 200 2.550 3.300 4.195 6.660 7.000 1.060 940 3.200 2.500–8.000 15.00 8.75
1.000 250 3.100 3.990 5.100 7.000 7.700 1.360 1.140 1.800 5.000–9.000 20.00 12.13
GRP 40/50 25 400 540 650 1.200 1.300 160 160 15 8–45 0.04 0.03
65 25 400 540 650 1.200 1.300 160 160 17 8–45 0.05 0.03
80 40 440 600 720 1.300 1.400 190 175 20 20–90 0.08 0.05
100 40 460 640 800 1.370 1.450 220 200 25 40–120 0.12 0.08
150 50 500 720 890 1.680 1.750 250 240 30 70–300 0.26 0.17
200 80 600 870 1.130 2.000 2.100 325 300 60 150–500 0.42 0.27
250 100 660 1.000 1.290 2.300 2.400 370 330 90 200–700 0.86 0.60
300 100 900 1.280 1.600 2.800 2.900 430 390 140 300–1.000 1.50 0.94
350 100 1.000 1.430 1.810 3.058 3.170 500 450 205 300–1.500 2.80 1.71
400 100 1.220 1.670 2.100 3.600 3.700 550 500 220 500–1.800 3.70 2.20
500 150 1.680 2.220 2.700 4.300 4.400 650 580 550 8.00–2.500 6.50 3.87
600 200 1.950 2.570 3.120 4.500 4.600 780 700 750 1.200–4.000 8.10 4.83
700 200 2.300 2.990 3.650 4.750 4.850 920 820 1.000 1.500–5.000 12.60 7.39
800 200 2.550 3.300 4.100 6.660 7.000 1.060 940 1.400 2.500–6.500 15.00 8.75
1.000 250 3.100 3.990 5.100 7.000 7.700 1.360 1.140 1.800 5.000–9.000 20.00 12.13
Cast Iron ** 50 40 30 580 730 1.210 1.300 240 240 50 15–80 0.08 0.05
(EN-GJS-500-7 /
65 40 30 580 730 1.210 1.300 240 240 50 15–80 0.08 0.05
GGG-50 /
ASTM 80-55-06) 80 40 30 580 730 1.210 1.300 240 240 50 15–80 0.08 0.05
100 40 430 580 730 1.210 1.300 240 240 60 40–120 0.12 0.08
150 40 490 690 850 1.440 1.600 260 240 200 50–300 0.26 0.17
200 80 620 810 1.000 1.670 1.780 300 280 270 100–500 0.42 0.27
250 100 890 1.250 1.460 2.420 2.540 380 450 520 160–800 0.86 0.60
300 100 890 1.250 1.460 2.420 2.540 380 450 520 200–1.100 1.50 0.94
350 100 1.010 1.325 1.670 2.730 900 485 465 650 300–1.500 2.80 1.71
400 100 1.010 1.325 1.670 2.730 2.900 485 465 650 400–2.000 3.70 2.20
* Dependent on pressure phase, ** Rubberlined on request, *** Dependent on filtration degree **** EconSense® is a processor controlled flush water management
system. For EcoSense® control and functions the Em4 processor LCP has to be used.
5
www.krone-filter.com
24" / DN 600 KAF® Filter – Bioethanol plant 3 x 16" / DN 400 KAF® Filter – desalinisation
6
www.krone-filter.com
Product range
Self cleaning filter • KAF® Self cleaning
Bernoulli®-filter
• KRF Backflush-filter
7
www.krone-filter.com
KF-PCIII-01-2018-D4M18003-Rev. 4.3
KRONEFILTER.COM
®
Phone +49 42 07 9 87 69-0 | Fax +49 42 07 9 87 69-27
filter@krone-filter.com | www.krone-filter.com
www.shop.krone-filter.com S O L U T I O N S I N F I LT R AT I O N
DESCRIPTION Single, duplex and self-cleaning automatic filter with several housing sizes
and combinations made from standard materials spheroidal iron castings
EN-GJS-500-7 (GGG 50)* or EN-GJS-400-15 (GGG 40), carbon steel optional
rubber lined or stainless steel.
APPLICATION Filter depending on type for diesel oil, oil or water piping systems in
ship and offshore installations classed or intended for Classification with
Lloyd’s Register.
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to
in this clause as the 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
RATINGS, cont. Temperature
Material: For fluids**:
range:
MDO, oil, water,
Spheroidal cast iron -10 up to +300°C
seawater
Austenitic stainless steel:
1.4571, 1.4401, 1.4404, 1.4408,
1.4539, 1.4301, 1.4541, MDO, oil,
-196 up to +300°C
SA240-304L, SA240-316Ti, nitrogen
SA240-321, SA240-316L,
SA240-904L,
Duplex stainless steel:
1.4462, 1.4463, UNS S31803
-40 up to +250°C seawater
Super duplex: 1.4410,
UNS 32750
Carbon steel: St 50, P235GH,
MDO, oil, water,
P245GH, P250GH, P265GH, -40 up to +100°C
seawater
SA516 Gr60, SA516 Gr70
**) including fluids and mixture of similar evaluation class
Pressure reductions at elevated temperatures are to be considered.
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to
in this clause as the 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
The Type Approval does not eliminate the need for normal inspection and survey procedures required by the Rules and
Regulations.
If the specified standards are amended during the validity of this certificate, the product is to be re-approved prior to it
being supplied to vessels to which the amended standards apply.
The Design Appraisal Document No. HTS/ENS 34963-16 and its supplementary Type Approval Terms and
Conditions form part of this Certificate.
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to
in this clause as the 'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense
caused by reliance on the information or advice in this document or howsoever provided, unless that person has signed a contract with the relevant
Lloyd's Register entity for the provision of this information or advice and in that case any responsibility or liability is exclusively on the terms and
conditions set out in that contract.
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34963-16
Issue number 0
Page 1 of 2
The undernoted documents have been reviewed for compliance with the requirements of the Lloyd’s Register’s
Type Approval System Procedure TA14 and this Design Appraisal Document forms part of the Certificate.
APPROVAL DOCUMENTATION
Lloyd's Register Group Limited, its affiliates and subsidiaries and their respective officers, employees or agents are, individually and collectively, referred to in this clause as
'Lloyd's Register'. Lloyd's Register assumes no responsibility and shall not be liable to any person for any loss, damage or expense caused by reliance on the information or
advice in this document or howsoever provided, unless that person has signed a contract with the relevant Lloyd's Register entity for the provision of this information or
advice and in that case any responsibility or liability is exclusively on the terms and conditions set out in that contract.
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34963-16
Issue number 0
Page 2 of 3
Lloyd's Register EMEA Date
Hamburg Technical Support Office 09 September 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC1461050/34963-16/TS
E-mail: hamburg-technical-support@lr.org
TEST REPORTS
HPC1461050/01 LR Works Inspection including hydrostatic burst pressure tests at 100 bar for 14.12.2015
type KSF: DN 50, size 2; KSF: DN 80, size 4 and KSF: DN 100, size 8
HPC1461050/02 hydrostatic burst pressure tests at 100 bar for type KMF: 2 ½” size 4; 17.12.2015
type KDF-K : DN 80, size 6 and KDF-K: DN 20, size 2
witnessed by LR Surveyor at Krone in Oyten
HPC1461050/03 hydrostatic burst pressure tests at 40 bar for type KAF: DN 200, PN 10 and 21.12.2015
at 64 bar for type KDF-V: DN 150, size 7, PN 16
witnessed by LR Surveyor at Krone in Oyten
HPC1461050/04 Visit of an existing installation with function test of KAF self-cleaning 11.01.2016
automatic filter at ‘Elbphilharmonie Hamburg’
Torsten Schröder
Senior Specialist
Engineering Systems
Hamburg Technical Support Office
Lloyd’s Register EMEA
T +49 (0)40 328107-463
E torsten.schroeder@lr.org
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.
Document no: HTS/ENS 34963-16
Issue number 0
Page 3 of 3
Lloyd's Register EMEA Date
Hamburg Technical Support Office 09 September 2016
Am Sandtorkai 41
20457 Hamburg Please quote this reference number on all future communications
Telephone +49 (0)40 328107-0 Fax +49 (0)40 328107-480 HPC1461050/34963-16/TS
E-mail: hamburg-technical-support@lr.org
Type Approval is based on the understanding that the manufacturer’s recommendations and instructions and
any relevant requirements of the Rules and Regulations are complied with.
Type Approval does not eliminate the need for normal inspection and survey procedures required by the Rules
and Regulations.
Lloyd’s Register EMEA reserves the right to cancel or withdraw this Type Approval Certificate in accordance with
the LR Type Approval System Procedure.
This is a copy of an electronic document. In the event of any conflict or ambiguity between the copy and the electronic document,
which is retained and published by Lloyd's Register, the original electronic and certified version shall always prevail.