Sei sulla pagina 1di 2

Dynamic Modeling and Simulation Software

VisSim is a visual simulation environment for modeling


the behavior of linear, nonlinear, continuous time,
discrete time, SISO, MIMO, multi-rate, and hybrid
system designs on the Windows 3.1, 95, and NT
platforms.
VisSim offers a uniquely integrated approach to model
construction, simulation, validation, and optimization,
which leads to rapid prototyping, faster execution, and
greater productivity. Furthermore, because VisSim
eliminates traditional programming, all modeling and
simulation tasks can be accomplished without writing a
line of code.
VisSim has proven its value on thousands of engineering
projects, spanning a wide range of industries and
disciplines, including precision motion control, continu-
ous processes, automotive, HVAC, chemical processes,
pulp and paper, nuclear power, missile guidance
systems, hydraulic activators, and closed-loop control.
Whatever your dynamic simulation needs may be, VisSim
Simulation of a 6th order plant - PID controller closed-loop system with automatic on-line controller is there for you.
gain optimization.

9 110+ mathematical, engineering, and scientific 9 Continuous, discrete-time, MIMO, SISO, 9 Interactive plots and strip charts
blocks with linear and nonlinear support multi-rate, and hybrid simulation — XY*, time domain, FFT, and discrete plots
9 Toolboxes: controls, electromechanical, Padé 9 Interactive, batch, auto-restart, and single- — Log, semi-log and linear scales
approximations, signal generation and processing step execution modes — Automatic Y scaling and selectable time
9 Euler, trapezoidal, Runge Kutta 2nd and 4th axis scaling
9 Component libraries: DSP, dynamic, electrome-
orders, adaptive Runge Kutta 5th order, — Multi-XY traces
chanical, electrical, hydraulic, process and
adaptive Bulirsh-Stoer, and stiff backward — Over plotting* and plot zooming*
chemical, thermal, turbines
Euler integration algorithms — Color coding, geometric markers, and
9 Drag-and-drop block diagram construction labels
9 MIMO stateSpace and transferFunction
9 Large model development — Custom background and foreground
blocks for ABCD matrices
— Explorer window for easy navigation colors
— User-specified
— Hierarchical model structure with password — Save data in ASCII, .M, .MAT, and .WAV
— Imported from MatLab® .MAT or .M files
protection formats
— Embedded subdiagrams 9 Simulation control panel
9 Man-Machine Interface
— Auto check for complete wiring 9 Parameter optimization with Powell, Polak-
— PID faceplates
— Connector labels with class names Ribiere, Fletcher-Reeves, or user-written
optimizer — Animated controls for switches, knobs,
— Global, local, and scoped variables and indicator lamps
— Find and replace variables 9 1-D, 2-D, and 3-D look-up tables
— Audio and visual alarms
9 Vector and matrix operations 9 Connector value probe with scalar, vector — Cycle through, pie area, pushbutton,
and matrix support horizontal, and vertical hit testing on
9 FIR and IIR filter design
9 State checkpointing buttons
— Bessel, Chebyshev, Butterworth, and Inverse
Chebyshev 9 Error highlighting 9 Graphic and line animation
— Differentiator and Hilbert transform design 9 Implicit system solving with Newton- 9 Dynamic bar graphs, needle meters, and
— Optional "tapped delay" implementation for Raphson or user-written optimizer histograms
discrete filters 9 Data typing and propagation with overflow 9 Presentation, display, training, and block
— Coefficient and filter method display checking for fixed point simulations labels modes
9 Data I/O in ASCII, .M, .MAT, and .WAV formats 9 Automatic conversion of s- and z-domain 9 Bitmap library
— Data logging with gating transfer functions * Available in plot block only.
— Custom data column separators
9 DLL interface to create custom blocks written in C,
Fortran, Pascal, or Visual Basic
9 DDE with Copy Link and Paste Link
9 Customizable toolbar
9 Windows Clipboard support
ANIMATION BOOLEAN INTEGRATION NONLINEAR REAL TIME (opt) TIME DELAY
animate > integrator case encoder timeDelay
lineDraw < limitedIntegrator crossDetect frequency unitDelay
>= resetIntegrator deadband PWM
<= int rt-DataIn
ANNOTATION == limit rt-DataOut TRANSCENDENTAL
bezel != NEURAL NET (opt) map acos
comment and max asin
date not merge SIGNAL CONSUMER atan2
index LINEAR SYSTEM display bessel
or min
label stateSpace error cos
xor quantize
scalarToVec transferFunction export cosh
relay
variable sampleHold histogram exp
vecToScalar DDE light ln
MATRIX OPERATIONS
wirePositioner DDE meter log10
buffer
DDEreceive OPTIMIZATION plot sin
dotProduct
DDEsend constraint stop sinh
ARITHMETIC fft
cost stripChart sqrt
1/X ifft
globalConstraint tan
-X GENERAL invert
parameterUnknown tanh
* embed multiply
unknown SIGNAL PRODUCER
/ expression transpose
button
abs userFunction vsum
const
convert RANDOM GENERATOR import
gain gaussian parabola
pow uniform pulseTrain
sign PRBS ramp
summingJunction realTime
unitConversion sinusoid
slider
step

2e^T\UTC_\edY_^c

9 VisSim/DSP: Rapid prototyp- Micro-VisSim is an entry level


ing of controller to DSP or product offering all of the
functionality of Professional
embedded system
VisSim except:
9 VisSim/Comm: Modeling and 9 No userFunction block
simulation of analog and
9 Limited to 100 blocks
digital
for model development
communication systems
9 No VisSim Viewer
Micro-VisSim also includes a
seven-state version of
9 VisSim/Neural-Net VisSim/Analyze.

9 VisSim/fuzzyTECH

FYcCY]FYUgUb

Maximum blocks 500 MB* 9 32-bit Windows Professional VisSim includes


Maximum plots 500 MB* (Win 3.1+/Win 32s, VisSim Viewer, a run-time, view-
only version of VisSim. The Viewer
Maximum integrators 500 MB* Win 95+, or Win NT 4+)
enables users to distribute VisSim
Maximum data 200 MB 9 4 MB RAM models to individuals not licensed
points per plot 9 2 MB disk space to use VisSim. Recipients of the
Viewer can run simulations,
Block nesting 500 MB* 9 3½" floppy drive
change block and simulation Windows® 3.1,95,NT
Integration methods 7 parameters, optimize gains, and Compatible

Numeric precision IEEE 64-bit perform interactive "what if"


scenarios.
Data file format ASCII, .M, .MAT,
and .WAV
ABCD state-space .MAT and .M Tel: 978-392-0100
format 1-800-VISSIM-1
Fax: 978-692-3102
* Limited only by memory. Email: sales@vissol.com
Web site: www.vissim.com
Copyright © 1999 Visual Solutions, Inc. All Rights Reserved.

Potrebbero piacerti anche