Sei sulla pagina 1di 123

PRODUCT DATA SHEETS

- MARINE CARE -

MARINE CARE B.V.


Mozartlaan 3
P.O. Box 270 – 3140 AG Maassluis (Rotterdam) / The Netherlands
Tel. 31-(0)10-2950342 – Fax. 31-(0)10-2950342 – email: supply@marinecare.nl
www.marinecare.nl
Bank account: ABN-AMRO, Accountnumber 60.77.62.039
V.A.T. NL806618395BO1/ K.v.K. Rotterdam 24281287
All transactions are subject to our general conditions of sale and delivery registered at Chamber of commerce R’dam
Table of Contents

Comparison Charts …………………………………………………………….. 4-5

Ports of Delivery …………………………………………………………….. 6

1.) Maintenance Products …………………………………………………….. 7

→ Careclean GP Enviro …………………………………………………….. 8


→ Careclean Degreaser GP …………………………………………….. 9 - 10
→ Careclean Quick Split …………………………………………….. 11 - 12
→ Careclean OSD Enviro …………………………………………….. 13 - 14
→ Careclean ECS Quick Dry …………………………………………….. 15

→ Careclean ECS Safe …………………………………………………….. 16 - 17


→ Careclean ACC …………………………………………………….. 18 - 19
→ Careclean Carbon …………………………………………………….. 20
→ Careclean Filter …………………………………………………….. 21
→ Careclean Aquawash …………………………………………………….. 22
→ Careclean Multiclean …………………………………………………….. 23

2.) Scale & Rust Removers …………………………………………………….. 24

→ Careclean F Descalex P …………………………………………….. 25 - 26


→ Careclean HD Descalex L …………………………………………….. 27 - 28
→ Careclean Rust …………………………………………………….. 29 - 30
→ Careclean Separator …………………………………………………….. 31

3.) Corrosion …………………………………………………………...... 32

→ Caretan Corrosion …………………………………………………….. 33 - 34


→ Carecoat 402 …………………………………………………………….. 35 - 36
4.) Watertreatment …………………………………………………………….. 37

→ Caretreat 1 Evaporator …………………………………………….. 38 - 39


→ Caretreat 2 Diesel …………………………………………………….. 40 - 41
→ Caretreat 2 Diesel – Test Method …………………………………….. 42
→ Caretreat 2 Diesel – Plot Chart …………………………………….. 43
→ Caretreat 3 Boiler …………………………………………………….. 44 - 45
→ Caretreat 3 Boiler – Test Method …………………………………….. 46
→ Caretreat 3 Boiler – Plot Chart …………………………………….. 47
→ Caretreat 4 Condensate …………………………………………….. 48 - 49
→ Caretreat 5 Seawater …………………………………………………….. 50 - 51

→ Caretreat 6 PWT …………………………………………………….. 52 - 53

5.) Fuel Oil Treatments …………………………………………………….. 54

→ Caretreat Sludge …………………………………………………….. 55 - 56


→ Caretreat Combustion …………………………………………….. 57 - 58
→ Caretreat Economizer …………………………………………….. 59 - 60
→ Caretreat Valves …………………………………………………….. 61 - 62
→ Caretreat Soot …………………………………………………….. 63 - 64

6.) Tank Cleaning Chemicals ……………………………………………... 65

→ Caretank ECO …………………………………………………….. 66 - 67


→ Careclean Alkaline …………………………………………………….. 68 - 69
→ Careclean Alkaline Extra …………………………………………….. 70 - 71
→ Careclean Rust …………………………………………………….. 72 - 73
→ Careclean Neutral HCF …………………………………………….. 74 - 75
→ Careclean Degreaser GP …………………………………………….. 76 - 77
→ Careclean Degreaser HD …………………………………………….. 78 - 79
→ Careclean Degreaser HD Split ……………………………………... 80 - 81
→ Careclean Voyage …………………………………………………….. 82 - 85
→ Careclean Multiclean ……………………………………………………... 86
→ Careclean Aquawash ……………………………………………………... 87
→ Careclean GP Enviro ……………………………………………………... 88
→ Careclean Coaltar ……………………………………………………... 89 - 90
→ Careclean Buffer ……………………………………………………... 91 - 92
→ Careclean Air Fresh ……………………………………………………... 93
→ Careclean Pickling Liquid ……………………………………………… 94 - 95
→ Careclean Passivation Liquid ……………………………………… 96 - 97
→ Careclean Pickling Paste ……………………………………………… 98 - 99

7.) Special Products ……………………………………………………… 100

→ Careclean Sewage ……………………………………………………… 101 - 102


→ Careclean Ultrasonic ……………………………………………………… 103 - 104
→ Careclean Hand ……………………………………………………… 105
→ Caretreat Bacteria ……………………………………………………… 106 - 108
→ Carefloc …………………………………………………………….... 109 - 110
→ Careclean High Pressure Clean (HPC) ………………………………. 111 - 112

8.) Test Kits ………………………………………………………………………. 113

→ Test Kit P-Alkalinity ………………………………………………………. 114 - 115


→ Test Kit Chloride ………………………………………………………. 116
→ Test Kit Nitrite ………………………………………………………. 117 - 118
→ Caretreat 2 Diesel – Test Method ………………………………………. 119
→ Caretreat 2 Diesel – Plot Chart ……………………………………….. 120
→ Caretreat 3 Boiler – Test Method ……………………………………….. 121
→ Caretreat 3 Boiler – Plot Chart ……………………………………….. 122
MARINE CARE NEAREST PRODUCT COMPARISON CHART

Marine Care Unitor (Vecom) Drew Uniservice

Maintenance

Careclean GP Enviro Enviroclean Veclean GP Enviromate 2000 Ecoclean


Careclean Degreaser GP Coldwash HD Degreaser GP OGR Cold Wash
Careclean Quick Split Cleanbreak Veclean Degr. Clear Break OWS Clean Break
Careclean OSD Enviro Seacare OSD Oil Spill Dispersant OSD-LT Ecodis
Careclean ECS Quick Dry / ECS Quick Dry / Lectro Clean Fast
Careclean ECS Safe Electrosolve E Veclean Electro Drew Electric 2000 Lectro Clean Slow
Careclean ACC Air Cooler Cleaner Air Cooler Cleaner ACC 9 Air Cooler Cleaner
Careclean Carbon Carbon Remover Carbon Remover Carbon Remover Carbon Remover
Careclean Filter / Filterclean Drew FC Filter Clean
Careclean Aquawash Uniwash / / Genepol
Careclean Multiclean Fore + Aft / Aquabreak PX Multicleaner-TP02 Edge Marisol
Careclean High Pressure HP Wash HPC / /

Scale and Rust removers

Careclean F Descalex P Descalex Descalent F Saf Acid Safe Descaler Powder


Careclean HD Descalex L Descaling Liquid Descalent HD Descale-It Descaling Liquid
Careclean Rust Metal Brite Vecosan Rustcleaner Drew RSR Rust Remover
Careclean Separator Disclean Seperator Cleaner Drew DC LO Seperator Clean

Coatings/Corrosion

Caretan Corrosion / Navatan 2006 S Drewtan RC Navalan Rust Converter

Watertreatment

Caretreat 1 Evaporator Vaptreat FWG Evap QC1 Ameroyal Liquivap


Caretreat 2 Diesel Rocor NB Liquid CWT Diesel QC2 Liquidewt NCLT
Caretreat 3 Boiler Combi/Auto/Liquidtreat BWT QC3 Organic AGK100/Adj.B+GC BWT One Shot / OBWT - 3
Caretreat 4 Condensate Condensate Control BWT QC4 Organic SLCCA/Amerzine OBWT - 4
Caretreat 5 Seawater Biogard SWT Vecosperse Drewsperse SWD Ecosperse (plus)
MARINE CARE NEAREST PRODUCT COMPARISON CHART

Marine Care Unitor (Vecom) Drew Nalfleet

Fueltreatment

Caretreat Sludge Fuel Care Sludge Conditioner Amergy 222 FOT


Caretreat Combustion Diesellite Combustion Improver Amergy 1000 FOT Dual Purpose
Caretreat Economizer Soot Remover Liquid Veclean Econotreat LT Soot Release Economizer Treat Liquid
Caretreat Soot Sootremover Sootremover Soot Release Soot Remover

Tankcleaning

Careclean Alkaline Aquatuf Waterbased Alk LAC Alkaclean Safety


Careclean Alkaline Extra Alkleen Liquid Waterbased Alk HD Drew ABD Alkaclean
Careclean Neutral HCF Alkleen Safety Liq. Waterbased Neutral HCF Drew NBD Waterbased Neutral HCF
Caretank ECO / / / /
Careclean Degreaser GP Coldwash HD Degreaser GP OGR Cold Wash
Careclean Degreaser HD Tankclean Degreaser HD / /
Careclean Degreaser HD Split / Veclean Tank / Tankclean Seperating
Careclean Voyage (Seaclean) Seaclean Tankclean at Sea TC4 Seaclean
Careclean Coal Tar / Coal Tar Cleaner / Coaltar Remover
Careclean Buffer / Bufferclean Drew BC Buffer Clean 5.5
Careclean Air Fresh / Veclean Air Fresh Drew AF Air Fresh
Careclean Pickling Liquid / Pickling Liquid Pickling Liquid Stainless Steel Pickling
Careclean Passivating Liquid / Passivating Liquid Passivating Liquid Stainless Steel Passivating
Careclean Pickling Paste / Pickling Paste / Stainless Steel Pickling
Careclean Rust Metal Brite Vecosan Rustcleaner Drew RSR Rust Remover
Careclean GP Enviro Enviroclean Veclean GP Enviromate 2000 Ecoclean
Careclean Multiclean Fore + Aft Multicleaner-TP02 Edge Marisol

Special Products

Careclean Sewage Gamazyme BTC Microtreat L Biotal MDS 2000 Microfresh Liquid
Careclean Hand Natural Handcleaner Handcleaner / Green Gelatin
Careclean Ultrasonic Unitor USC Ultrasonic Multicleaner / Ultrasonic Multicleaner
Marine Care Chemicals – Ports of Delivery

Argentina Beunos Aires Italy Augusta South Africa Cape Town


Australia Sydney Genoa Durban
Belgium Antwerp Livorno Richards Bay
Gent Ravenna Port Elisabeth
Zeebrugge Taranto (Bari) South Korea Pusan
Oostende Triest Ulsan
Brazil Santos Venice Spain Algeciras
Rio de Janeiro Latvia Riga Barcelona
Recife (t/c only) Liepaja Bilbao
Canary Islands Las Palmas Ventspils Valencia
China Shanghai Lithuania Kleipeda Turkey Istanbul
Ningbo Butinga United Arab Dubai
Egypt Suez Netherlands Rotterdam Emirates Sharjah
Port Said Moerdijk Fujairah
Estonia Tallin Amsterdam Jebel Ali
Muuga Delfzijl Khor Fakkan
France Bordeaux IJmuiden United Kingdom All ports
Dunkerque Terneuzen United States Houston
Le Havre Vlissingen Los Angelos
Marseille Poland Szczecin Miami
Germany Bremerhaven Portugal Lisbon Port Everglades
Hamburg Leizous New Orleans
Gibraltar Gibraltar Russia Kaliningrad New York
Greece Pireaus St. Petersburg San Francisco
Hong Kong Hong Kong Singapore Singapore

Marine Care B.V. – Mozartlaan 3 – 3144NA Maassluis / The Netherlands


Phn: +31 10 29 50 342 / Fax: +31 10 29 50 345 – info@marinecare.nl / www.marinecare.nl
PRODUCT DATA SHEETS

- Maintenance Chemicals -
CARECLEAN GP ENVIRO

A water based general purpose degreaser for engine room and


deck cleaning

• Contains no petroleum solvents, non-flammable.


• Biodegradable, non-toxic, waste water will split into an oil/water phase.
• Clean, fresh odor.
• Retains strong degreasing properties when diluted.
• Leaves no film residues on cleaned surfaces.
• Economical in use.
• Suitable on most common metals and coatings.
• Suitable for use in conjunction with oil water separators.

Application

Careclean GP Enviro is used for engine rooms, decks, bulkheads and accommodation.

Directions for use

For heavy contamination


Careclean GP Enviro is applied by spray undiluted and left for 20-60 minutes. It must then be hosed
off with a powerful waterjet, whilst brushing the surfaces.

General Cleaning
Careclean GP Enviro can be diluted to a 2% solution in water for light cleaning. It must be allowed
to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product is increased
by using water at a temperature of 20 up to 60o C for dilution and rinsing.

Properties

Soluble in water. Pale yellow colored liquid with a fresh odor.

Specific gravity (20o C) : 0.995


Flash point (PM CC) : None to boiling (100° C)
pH (1% solution) : 9.1

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER GP

Emulsifying cleaning agent for the removal of medium to heavy mineral oils and fats by
spraying and brushing.

• Emulsifying cleaning agent based on aliphatic hydrocarbons, non-ionic and anionic


surface active agents.
• Most universally applicable product form the series of emulsifying cleaning agents.
• Suitable for the removal of most mineral oils and fats and preserving agents.
• Safe for use on common metals, epoxy and zinc-silicate coatings.

Application

Cooling systems
Along with the usual lime deposits, traces of mineral oils are often found in cooling systems.
These oil and fat deposits hinder optimum removal of the hardness deposits when using acid
cleaners (e.g.Careclean F Descalex P). In such cases, it is recommended to use an emulsifying
cleaner before the acid cleaning, to remove these deposits. Careclean Degreaser GP is ideal in
these cases.

Spraying
Careclean Degreaser GP can be sprayed undiluted onto the components to be cleaned.

Tanks
Careclean Degreaser GP can be used for the removal of most mineral oils and fats in loading and
storage tanks.

Directions for use:

Cleaning of cooling systems


Fill the cooling system with an emulsion of Careclean Degreaser GP and water. Depending on the
degree of contamination, 100 liters of cleaning liquid should contain 5 to 10 liters of Careclean
Degreaser GP.
Allow this emulsion to circulate for 12 - 24 hours at maximum temperature of 60°C. After this
operation, drain the cleaning liquid and rinse the system intensively with water until the outlet
water remains clear. Add cooling water treatment Caretreat 2 Diesel into the system.
Spray method
Spray the objects to be cleaned until they are thoroughly dampened with undiluted Careclean
Degreaser GP. Let the product act for 20-60 minutes, then rinse the objects thoroughly with water.

Note: Objects subject to corrosion should not be rinsed with water; use in this case, for example,
Careclean ECS Quick Dry.

Cleaning of tanks

Prewash
Before cleaning with Careclean Degreaser GP it is recommended to prewash with hot water at
approximately 60o C, except for drying and semi-drying oils where a prewash with cold water
should be applied.

Spray method
Spray the tank with undiluted Careclean Degreaser GP until the walls are thoroughly dampened
and then let the product soak in for at least 30 minutes. Rinse each tank compartment for 45
minutes with water at 60oC.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A
range of support equipment is also available.

Properties:

Undiluted at room temperature or in emulsions with water up to 6% at a maximum temperature of


60°C.
It can also be used on plastic materials, epoxy and zinc-silicate coatings. Light yellow neutral
liquid. Non-corrosive. Emulsifiable with water.

Specific gravity 20°C : 0.82


Flash Point PM CC : 65°C
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN QUICKSPLIT

A solvent based quick separating oil and grease remover suitable for use in conjunction
with oily water separators and where IMO rules are required.

* Based on aliphatic hydrocarbon solvents, selected non-ionic and anionic surfactants which are
biodegradable.
* Good cleaning properties and fresh odour.
* Its emulsion with water and oil breaks up within a very short period. Less than 15 ppm oil
remains in the water and therefore the product meets the requirements of IMO.
* Suitable for the removal of most mineral oils, fats, greases and preserving agents.
* Safe to use on all common metals, painted surfaces, epoxy and zinc-sillicated
coatings.
* Has the approval of major manufacturers for use in oil-water separators.
* It fulfils TS 6850-017, edition 4 of the German military force.
* High flashpoint.

Application:

General maintenance
Careclean Quicksplit is used to clean machinery, floor plates and bulkheads in engine rooms.

Tanks
Careclean Quicksplit can be sprayed undiluted as a spotcleaner in tankcleaning (Marpol
requirements).

Directions for use:

General maintenance
For cleaning in engine rooms etc., Careclean Quicksplit is used undiluted. Dampen the surface
to be cleaned and let the product act for 5 - 60 minutes. Brush the surfaces occasionally and
finally rinse them thoroughly with water at 50 - 60o C. For heavier contamination we
recommend Careclean HD Split.
Tanks
To be used as a spotcleaner to decrease the amount of slops. Spray the surfaces to be cleaned until they
are thoroughly dampened with undiluted Careclean Quicksplit. Let the product act for 5-60 minutes,
then rinse thoroughly with water at 50 - 60o C.

For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range of
support equipment is also available.

Immersion baths
Careclean Quicksplit is applied undiluted at ambient temperature or up to a maximum of 55o C in a
heated tank. Soak components for several hours, remove from the bath and rinse thoroughly with a
waterjet.

Practical hint
Where an oil-water separator is installed, collect the treated bilge water in the dirty water collecting
tank. After a reasonable separating time suck the bilge water from the bottom of the tank and discharge
overboard through the oil-water separator. This is the best way to keep within the IMO rule limits
(max. 15 ppm oil in the discharge overboard).

Note: The use of emulsifying products (old style degreasers) will affect the separating properties of
Careclean Quicksplit.

Properties

Clear yellow brown colored liquid. Mixture of aliphatic hydrocarbons and biodegradable surface
active agents. Non-emulsifiable in water.
The product is safe for use on all common metals.

Special gravity : 0.792


Flash point PM CC : above 61 °C
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN OSD ENVIRO

 Fast acting dispersion of oils.


 Contains no petrochemical solvents.
 User friendly and non-flammable.

Directions For Use


Careclean OSD Enviro oil spill dispersant should be used neat and can be applied by spraying
from the surface vessels. Used neat it will disperse in practice a ratio of about 2 to 4 times its
own volume.

Application
Careclean OSD Enviro oil spill dispersant should be sprayed onto the oil slick using spraying
equipment connected to booms with spray nozzles supplied by a pump from storage tanks.
When using the product the sea surfaces should be agitated using breaker boards, boat
propellers, bow wave ect. to help disperse the oil. When dealing with small spills from vessels,
use hand spray pump or an eductor and fire hoses or monitor. This will mix the dispersant with
seawater, and agitating the sea will help break up the oil slick as well as applying the
dispersant. This technique has also proved valuable when dealing with small spills in ports and
harbors between ships side, wharfs and pilings, ect. or any area which has difficult access.

Beach and Shore Application


Careclean OSD Enviro oil spill dispersant may be used for the beach and shore cleaning.
Before using Carelcean OSD Enviro on beaches, the local environmental, social, economic and
political consideration should be taken into account. Where application is justified, the most
appropriate method of use will depend on the type of shore line, type of oil and amount. When
a beach has oily liquid from a spill, it is advisable to remove as much of it as possible
mechanically before using a dispersant. The amount of dispersant used is dependent on the
type of oil. In cases of light to medium crude oils and light to medium fuel oils, Careclean
OSD Enviro will be sufficient. For heavier oils or mousse-like residues, we advise the use of
Careclean OSD. Apply the dispersant over the oil working from the low watermark upwards,
before a rising tide, or in areas where it is calm or small tidal movements, use hoses to wash
down the shore line to remove oil from rocks and beach.

Technical Information
The effectiveness of the oil dispersant will vary depending on the state of the oil, i.e., its pour
point and viscosity at sea temperature and the time of weathering, evaporating of the lighter
fractions of oil and the formation of oil-in-water emulsions which will all quickly increase
viscosity and pour point and hence increase resistance to dispersion.
To be effective, it is essential to use Careclean OSD Enviro as early as possible in the cleanup
operation. We recommended users of oil dispersants to read the IMO publication ‘IMO/UNEP’
Guidelines on Oil Spill Dispersants Application and Environmental Considerations’. This book
gives more information on the application of dispersants. We would also like to point out that
the use of dispersants in many countries is governed by local authorities or Coast Guard and
permission to use the product must be sought.

Typical Physical Properties

Composition: an aqueous blend of glycols, glycolethers, nonionic and anionic surfactants.

Specific Gravity (25°C) : 1.0


Flash Point (PMCC) : none
pH (10% solution) : 6.8
Viscosity : 13 mPa.s (0°C)
: 4 mPa.s (20°C)
Cloud point : < - 3°C (26.6°F)

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN ECS QUICK DRY

A non-conductive degreasing electro cleaner which evaporate fully and is non corrosive.

• Fast safe removal of all common contamination on electrical components.


• Careclean ECS Quick Dry has no flash point and can be used safely on running equipment.
• Product displaces water.

Application

Spraying

Use Careclean ECS Quick Dry for switchboards, motors etc. If used in an enclosed space, keep well
ventilated. Use spray equipment which gives a fine spray but no fogging for best results. Once the
product has acted, use again to flush off contamination and afterwards blow dry with air.

Properties

Colourless water free liquids which evaporate fully.


Specific gravity (20%) : 1.323
Flash point PM CC : None
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ECS SAFE

Odorless, non-emulsifying degreasing agent and non-conductive


electro cleaner

• Special degreasing agent for the removal of oil and grease from machines and motor parts,
transmissions, ball bearings, gear wheels, metal parts, electrical components, etc.
• Odorless.
• Contains no chlorinated hydrocarbons or other harmful chemicals.
• Does not emulsify in water - the polluted oil can be separated by means of an oil/water
separator.
• High flash point.

Application

Careclean ECS Safe can be applied with a brush or by spraying the parts to be cleaned. This product
can also be used by filling an immersion bath to clean extremely dirty parts. The high flash point and
the fact that it is practically odorless makes Careclean ECS Safe a pleasant and problem free product.

Directions for use

Immersion Baths
Careclean ECS Safe is used undiluted and unheated in immersion baths. Put the parts to be cleaned in
the bath and soak for several hours. Thereafter, take the parts out of the bath and spray off with a
forceful waterjet.
Attention: parts that need to be rust free and dry (such as electrical components) should not be sprayed
clean with water but with clean Careclean ECS Safe and afterwards should be blow-dried completely
because of fire risk if residues are left behind.

General Cleaning
For the cleaning of dirty parts and surfaces use Careclean ECS Safe undiluted. Moisten the parts to be
cleaned thoroughly with the product. Depending on the measure of dirt, soak the product for 5 to 60
minutes, brush in between. After this, rinse thoroughly with water.
Attention: parts that need to be rust free and dry (such as electrical components) should not be sprayed
clean with water, but with Careclean ECS Safe and afterwards should be blow dried completely to
avoid fire risk.

Attention
Cold cleaners should only be used in combination with oil/water separators.
To guarantee an optimal oil/water separation, cold cleaners should never be used with greater amounts
of emulsifying cleaners (e.g. of High Pressure Cleaners) if the waste is passing oil/water separators.

Properties

Clear, odourless, fluid neutral degreasing agent based on among other things, high boiling aliphatic
hydrocarbon. Careclean ECS Safe evaporates without residue. Careclean ECS Safe can be used on
most metals, synthetic material, rubber and hardened metals, electrical components.

Specific gravity (20o C) : 0.758


Flashpoint : 62o C
pH :7

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ACC

For manual and "in service" cleaning of Diesel Engine charge air coolers.

* Effective removal of all contaminants.


* Anti corrosive properties.
* No impact on cylinder oil films.
* Completely combustible in the cylinder.
* Dosing systems available.

Application

Immersion bath
Dependant on design, the cooler is flooded with Careclean ACC or immersed in a tank full of
product. The product should be heated to approx. 50°C and agitation provided with an air line.
After 2 hours, drain off and flush well with water, followed by drying with an air line.

Circulation method
Some designs of cooler can be circulated "in situ". In this case a pump tank and pipe system is
fitted permanently or connections are provided for connecting a temporary circuit. The system
should be filled with Careclean ACC and circulation carried out for 2 - 4 hours at a temperature of
upto 50°C.
After cleaning the cooler should be thoroughly flushed with fresh water and dried with an air line.

Note: Both cleaning methods benefit from heat of up to 50°C and cleaning times can be reduced
or extended dependant on temperature and degree of fouling.

Direct injection
Careclean ACC has the approval of the majority of major manufacturers for use either in their own
design of "in service" cleaning system or other recognised systems provided by suppliers.

Injection systems
Marine Care offer a range of newly developed easy to operate manual systems.

Directions for use

Regardless of the type of "in service" system used, Careclean ACC should be dosed at the ratio of 2
parts water added to 1 part product (in that order) and well mixed for immediate use.
If the emulsion is left standing for up to 5 minutes its composition will change and effectiveness
reduced. It is most important that 5 - 10 minutes after dosing the solution, injection with fresh
water only is repeated using double the total volume of the first solution to flush off the chemical
residual which contains the "solved" contamination. Failure to do this will result in a "sticky
cooler" which will foul very quickly.

Turbo blowers
The water washing of the air side of turbo blowers has been accepted for many years. Most
manufacturers provide nozzles and dosing pots to inject water into the volute casing after the inlet
filters. These systems can be utilised with a solution of Careclean ACC at the same ratio of 2 parts
water mixed into 1 part product and dosed via the water wash system.

Note: When cleaning turbo blowers "in service" follow the equipment manufacturers instructions
regarding engine load and/or blower revolutions during the procedure.

As with normal water washing, do not attempt to clean a badly fouled blower as resultant removal
of deposits could cause imbalance of the rotor.
The principle to follow is prevention not cure.

Injection systems
Marine Care can give advise on modifications to existing equipment or retrofit packages. For
further details refer to the equipment information sheet.

Properties

Light yellow coloured neutral fluids, which emulsify with water and are safe in contact with all
metals.

Specific Gravity (20°C) : 0.915


Flash point PM CC : 87 °C

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN CARBON

Liquid cleaning agent for use in immersion baths for removing partially
carbonized oils

• Consists of yellow top layer and brown under layer.


• Top layer contains water and a corrosion inhibitor. This prevents evaporation of the volatile
components in the under layer.
• Under layer is based on aromatic and chlorinated hydrocarbons, cresols and anionic surface
active substances, which remove heavy oils and most carbon contamination.
• Not corrosive on common metals.

Application:

Careclean Carbon is applied undiluted for cleaning of highly soiled components. (e.g. cylinder heads,
gear boxes, pistons, oil pumps, injectors, pipes, burners, tubes, coolers, oil filters.)
Also old paint and lacquers can be removed with Careclean Carbon.

Directions for use:

Immersion baths
Put the components in a steel bath filled with undiluted Careclean Carbon and let them soak for 2 to
10 hours, depending on the degree of contamination. Then take out the components and flush clean
with a powerful water-jet.

Properties

Careclean Carbon is a duel component liquid with a strong aromatic smell. It has no flash point, but
when used in immersion baths the flash point may fall in time to 80°C. Plastics and rubber should
first be tested for chemical attack.

Specific gravity : 1.1


Flash point PM CC : None
pH : Top Layer 11.7
Bottom Layer : 7.5

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN FILTER

Liquid cleaning agent for removal of partially carbonized oils using circulation method

• Based on a mixture of aliphatic and chlorinated aromatic hydrocarbons, cresols and anionic
surface-active agents.
• Removes partially carbonized oils.
• Timely cleaning prevents the formation of coke-like adherents.
• Non-corrosive.

Application

Careclean Filter is mainly used for the cleaning of permanently fixed oil coolers, oil pre-heaters and
metal/ceramic oil filters. These units are regularly contaminated by particles in the oil and partially
carbonized oils. Timely cleaning prevents the formation of coke-like adherents which are difficult or
impossible to remove.

Directions for use

Careclean Filter is used undiluted at cleaning temperatures not exceeding 60o C. The cleaning effect
is obtained by filling and/or circulating the product. Cleaning will take 8 to 24 hours depending
upon the degree of contamination.

Properties

Careclean Filter is a light brown colored fluid. Its formula includes cresols and chlorinated aromatic
hydrocarbons. Plastics and rubber should first be tested for chemical attack. The product may also
attack paints and lacquers.

Specific gravity : 1.04


o
Flashpoint PM CC : 62 C
pH (1% solution) : 8.7

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN AQUAWASH

A Completely biodegradable general purpose cleaner.

* Bio degradable
* Mineral oil free
* No organic solvents
* Non flammable
* Suitable for most surfaces

Directions for use

Spraying
For contamination, Careclean Aquawash is sprayed on undiluted and left for 20 - 60 minutes. It
must then be hosed off with a powerful waterjet, whilst brushing the surfaces.

General cleaning
Careclean Aquawash can be diluted to a 2% solution in water for light cleaning. It must be
allowed to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product
is increased by using water at a temperature of 20 up to 60°C for dilution and rinsing.

Properties

Careclean Aquawash is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.

Specific gravity (20°C) : 1.05


pH (1% solution) :7
Flash point : none

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN MULTICLEANER

A Completely biodegradable general purpose cleaner.

* Powerfull cleaner
* For general and tankcleaning
* No organic solvents
* Non flammable
* Suitable for most surfaces

Directions for use

General & Tankcleaning


Careclean Multiclean can be diluted to a 2-10% solution in water. It can be used for spraying,
recirculation and direct injection. The effectiveness of the product is increased by using water at a
temperature of 60 to 80°C for dilution and rinsing.

Properties

Careclean Multiclean is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.

Specific gravity (20°C) : 1.05


pH (1% solution) : approx. 9
Flash point : none

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Scale & Rust Removers -


CARECLEAN F DESCALEX P

Inhibited acid cleaning powders for removal of water scale and rust deposits from water
systems.

* Inhibited to prevent acidic attack on surfaces to be cleaned.


* Safe on rubber, plastic and jointing materials.
* Easy to handle.
* Suitable for most common metals except zinc, aluminium and galvanised materials.

Application:

Careclean F Descalex P is an inhibited sulphamic acid based products suitable for the cleaning of
boilers, condensers, evaporators, butterworth heaters and pipe systems etc.

Directions for use:

General

1. We recommend that a preliminary test is carried out on samples of the original scale or
deposit in order to select the most suitable acid cleaner and optimize concentration and
temperature conditions.
2. When a boiler is soiled with light oil deposits, or if silicates and/or calcium sulphates are
present, boiling out with Careclean Alkaline Extra is recommended.
3. If heavy mineral oil deposits are present in a boiler, a preliminary treatment with an
emulsifying cleaner, like Careclean HD Split or Careclean HD is recommended.
4. If heavy oil deposits are present in cooling systems a preliminary cleaning with the
emulsifying cleaning agent Careclean Degreaser GP is necessary.

Circulation Method

1. If present, remove zinc, aluminum, galvanized steel components before commencing the
cleaning operation.
2. Before cleaning with Careclean F Descalex P solution, we recommend thoroughly rinsing
with water. This will partly or completely remove loose sludge, scale, etc.
3. Depending on the nature of the scale and degree of contamination, it is recommend to use a
cleaning solution with a concentration of 3 - 10 kgs Careclean F Descalex P per 100 liters of
water. This solution can best be prepared by continuously stirring the powder into warm
water.
4. Solutions of Careclean F Descalex P may be heated to a maximum of 60o C, which will result
in a quicker cleaning process.
5. During the cleaning process, inflammable and/or toxic gases may be released, therefore
adequate ventilation must be provided. Avoid naked flames.
6. The length of the cleaning operation depends on the thickness and type of deposit and also on
the product concentration. Generally speaking this period will be within 24 hours.
7. After cleaning, drain off the solution and neutralize it with Careclean Alkaline Extra outside
the system.
8. The final rinsing can be carried out with a 1% solution of Careclean Alkaline Extra.

Cleaning in immersion baths


Fill a plastic or plastic-lined bath with a solution of Careclean F Descalex P in water. (1 kg
Careclean F Descalex P to 10 liters water).
Solutions of Careclean F Descalex P may be heated to a maximum of 60° C for a quicker cleaning
process. Introduce the components to be cleaned into the bath and let them soak for a maximum
of 24 hours, depending on the degree of scaling. Remove the components from the bath and rinse
them with a powerful waterjet.

Properties:

Light brown colored powder containing inhibitors and sulphamic acid. Non-flammable and not
hygroscopic.

Flashpoint : None
pH (1% solution) : 1.5

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN HD DESCALEX L

A Heavy Duty liquid acid descaler with anti-foaming properties

* Remover heavy deposits of water scale and iron oxides.


* Very effective without heat.
* Inhibited to protect cleaned surfaces from acidic attack.
* Can be used on most common metals.
* Effective lavatory system cleaner.

Application

Careclean Descalex L is suitable for cleaning boiler's condensers, evaporators, heat exchangers,
cooling and pipe systems. It must not be used on zinc, aluminum, stainless steel, galvanized
materials or cast iron.

Directions for use

General

1) We recommend that a preliminary test is carried out on samples of the original scale or
deposit in order to select the most suitable acid cleaner and optimize product concentration
and temperature conditions.
2) Where a boiler is soiled with light oil deposits, or if silicates and/or calcium are present,
boiling out with Careclean Alkaline Extra is recommended.
3) If heavy mineral oil deposits are present in cooling system, a preliminary treatment with an
emulsifying cleaner, such as Careclean HD Split or Careclean HD is necessary.
4) If heavy oil deposits are present in cooling systems a preliminary treatment with the
emulsifying cleaning agent Careclean Degreaser GP is necessary.

Circulation method

1. Remove zinc, aluminium, cast, iron, galvanised and stainless steel components before
commencing the operation.
2. Before cleaning with Descalex L solution we recommend thorough rinsing with water. This
will partly or completely remove loose sludge, scale, etc.
3. Depending on the nature of the scale and degree of contamination, 1 Ltr. of Descalex L is
added to 4-9 Ltr. of water. Further dilution with water is not recommended as the excellent
inhibiting effect will be reduced.
4. Descalex L is normally used cold. However the solution may be heated to a maximum of 55
C which will result in a quicker cleaning process.
5. During the cleaning process inflammable and/or toxic gases may be released, therefore,
adquate ventilation must be provided. Avoid naked flames.
6. The length of the cleaning operation depends on the thickness and type of deposit and also
on the concentration of the product used. Generally speaking this period will be within 24
hours.
7. After cleaning drain off the cleaning solution and neutralise with Careclean Alkaline Extra
outside the system.
8. Rinse the system thoroughly with water until there is a neutral reaction on pH paper.
9. Finally rinse with a 1% solution of Careclean Alkaline Extra .

Circulating system
Marine Care provides a portable circulating pump and tank systems ideal for this product. Please
refer to the Marine Care equipment information sheet.

Cleaning in immersion baths


Fill a plastic or plastic lined bath with a solution of Descalex L in water. (1 part DESCALEX L to 2
parts water). Descalex L is normally used cold but the solution may be heated to a maximum of 55C
for quicker results. Introduce the components to be cleaned into the bath and let them soak for a
maximum of 24 hours, depending on the degree of scaling. Remove the components from the bath
and rinse them with a powerful water jet.

Properties

Light brown liquid containing hydrochloric acid, completely miscible with water. Low foaming.
Suitable for use on most common metals, except zinc, aluminum, cast iron,
stainless steel or galvanized materials.

Specific gravity (20°C) : 1.15


Flash point pm cc : None
pH (1% solution) : 1.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN RUST

Acidic liquid product for the cleaning of aluminium, copper and removal of rust stains on
paint work.

* Cleans and brightens aluminium and copper.


* Removes rust stains without risk to paintwork.
* Safe on most common metals.

Application

Careclean Rust is used for the cleaning of aluminium floor plates, copper and brass fittings, wooden
decks and the removal of lime after tank cleaning operations.

Directions for use

In most cases Careclean Rust is applied by brush diluted in solutions ranging from 10-50% and left
to react for 5-10 minutes. Smaller objects can be soaked in plastic container. After cleaning, rinse
items thoroughly with a water jet.

Paintwork
Dilute Careclean Rust 1 liter of product to 4-9 liters water, apply the solution by brush or spray
using plastic equipment and leave to soak for 10-20 minutes. Rinse off using a powerful water jet
with a brush, if necessary.

Tankcleaning
If lime scale stains are present after completion of tank cleaning operations, inject 0.5 liters
Careclean Rust per 100 liters washing water directly into the automatic washing system approx. 20
minutes. The recommended temperature is 75-85°C.
For detailed instructions on tankcleaning refer to the Marine Care Tank Cleaning Manual.
A range of support equipment is also available.
Properties

Colourless fluid contains phosphoric acid. Non-flammable and completely soluble in water. Within
the reaction time suitable for use on all metals and painted surfaces.

Specific gravity (20oC) : 1.21


Flash point CC : none
pH (1% solution) : 2.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN SEPARATOR

Acid cleaning agent for cleaning stainless steel separator discs and separator bowl.

* A strong cleaning agent specially developed for cleaning stainless steel separator discs.
* Contaminants found on separator discs mostly consists of hardness salts (calcium
carbonate etc.) and partly carbonised oil. The combination of dissolving agents, acids and
surface active agents makes it possible to clean the separator discs quickly without
brushing.
* After cleaning the metal surface is passivated by the acid of the product.

Directions for use

Careclean Separator can only be used for cleaning stainless steel separator discs. Fill a stainless
steel or plastic container with pure Careclean Separator. Immerse the stainless steel discs in the
container and let the product act for 30 minutes up to a maximum of 2 hours. Heating the
product is not necessary. Do not put the discs closely packed into the liquid but take care that
there is enough space between them so that the product can work properly. Remove the discs
from the bath (wear rubber gloves) and rinse with a powerful waterjet. The cleaned separator
discs can be used immediately.

Properties
Careclean Separator is a colorless, strong acid, liquid cleaning agent with strong degreasing
properties. This product can only be used on austenitic stainless steel and is corrosive on all
other metals.

Specific Gravity (20°C) : 1,036


Flash point : None
pH (1% solution) : 1.8

For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the result.
PRODUCT DATA SHEETS

- Corrosion -
CARETAN CORROSION

Rust converter for use on rusted steel and sandblasted steel as pre-coating preparation.

* Neutralizes the corrosion process.


* Reacts quickly with the rust and transforms iron oxides into stable insoluble blue-black
metallo-organic complex inert surface.
* Effects a through chemical passivation of substrate making it a sound base for application of
subsequent coating systems.
* Gives a water insoluble hydrophobic film.
* Is an excellent adhesion promotor for subsequent paint or coating systems.
* Is NON-HAZARDOUS, NON-FLAMMABLE and DRY FILM IS FIRE RETARDANT.
* Only minimum surface preparation required. Degrease, remove loose rust flakes/scales with
brush or sandpaper etc. Wash off salt, oil and chemicals.
* Caretan Corrosion may also be applied to damp rusted surfaces.
* Reaction time required: 3 hours.
* Gives you cost-effective corrosion control and long-term protection qualities.
* Caretan Corrosion is compatible with mostly used paint types and coating systems, alkyd
systems, modified alkyds, chlorinated rubber, epoxies, polyurethanes, vinyls and the new
water-based paint systems.

Application

On all rusted steel surfaces before painting or repainting when preparation by sandblasting is a
problem, e.g. cargo holds, decks, hatch covers, superstructures, pipelines, winches, rails etc. It is
also used on sandblasted surfaces to prevent or passivate "flash rust". Beyond being particularly
suitable for use in the highly corrosive marine atmosphere it is indeed also suitable for use on
offshore oilrigs, in shipyards and refineries.

Directions for use


Remove loose rust, rust scales/flakes by thorough wire brushing. Millscale, rust chips, blisters,
deteriorated paints, oil, grease etc. should also be removed if present. In heavy industrial and
marine atmospheres rust always contains soluble salts. It is important to remove atmospheric salts
by water wash with freshwater prior to application of Caretan Corrosion.

Caretan Corrosion is ready to use. 1 single thin application is sufficient. Apply brush, roller or
spray. 1 liter covers approx. 20 square meters. Reaction time is 3 hours and paint/coatings must be
applied sooner. If the rustconverter is applied in confined areas, reaction time may be somewhat
longer.
Caretan Corrosion is not a paint. Treated surfaces must be protected by suitable paint/coatings,
preferably within 48 hours after application of Caretan Corrosion. Equipment should be washed
and flushed in clean water use.

CAUTION:
The rust converter should NOT be applied on hot surfaces above 40°C such as e.g. a deck area in
sunny tropical climate. Such areas should be treated only when the area has cooled down during
the evening and left for reaction overnight.

Properties

Caretan Corrosion is based on water reducible chelating polymers. Does NOT contain Phosphoric
Acid.

Appearance : Milky White/Cream colored liquid


Specific Gravity : 1.0
Viscosity : 15 m Pa.s.
Flash Point PM CC : None
pH value : Approx. 1.6
Stability : More than 1 year in closed container

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their applications lies outside our control
we cannot accept any liability for the results.
CARECOAT 402

Corrosion protection coating for permanent ballast tanks.

• Contains no solvents.
• Requires no special surface preparation prior to application.
• Can be applied on rusted steel or new steel and is compatible with old deteriorated
coatings.
• Is highly polar with strong molecular affinity for metal surfaces.
• Is easy to use – only one coat required.
• Can be applied by airless spraying or by brush or roller.
• Repair works such as welding and other “hot work” jobs can be carried out without
removal of the coatings.

Application

Carecoat 402 ballast coating is recommended for recoating of completely ruted ballast tanks
in all types of vessels, also in peak tanks, offshore leg support tanks, cofferdams, floating
docks, caissons, void spaces ect. It is also suitable for application on new steel provided mill
scale has been removed.

Directions for use

Surface Preparations
1.) For ships in service: No special surface preparation such as wire brushing or
sandblasting is required prior to the application. However, it is necessary to remove
mud and silt, loose rust, loose scales, debris and loose paints. Usually a thorough high
pressure water wash with 200 bar pressure is sufficient, eventually followed with light
scraping of tank surfaces. It is not necessary that tank surfaces are dry prior to the
application of the coating.
2.) For Lloyd’s Register corrosion control notation in association with reduced scantlings
the surface preparation must be in accordance with BS 4232-2 equivalent to Swedish
Standard Sa 2½ (SIS-05-5900-1988) at new building stage.

Airless Spraying
Product may be applied by airless spray using 45:1 ratio, with nozzle sizes “25” (0.025”inch;
type 163-725) or “27” (type 163-727) both with 70° fan angle. The use of alternative nozzle
sizes depends on the viscosity of the coating during application. Check the material
temperature.
Application Temperature
Do not apply at temperatures below 5°C (41°F). The minimum coating material temperature
for spraying is 12°C (54°F). In cold weather preheating of Carecoat 402 ballast tank coating
may be necessary. However, it should not be heated to a temperature exceeding 60°C (140°F).

Coverage/ Film thickness


• For long-term protection provided surfaces are not too rough: 3-4m²/liter at 250-300
microns wft. Rough surfaces/servere pittings: 2.5 m²/liter at 250-300 microns wft.
• For 1-2 years protection provided surfaces are not too rough: 4,5 - 6 m²/liter at 150-
200 microns wft.
• For 1 year protection, e.g. protecting fuel tanks during construction period of
newbuilding: 9-9,5m²/liter at 100 microns wft.

The coating is supplied ready for use – do not dilute.

Properties

Dark brown clear semi-thixotropic liquid of anticorrosive chemical compounds with high
contents of woolgrease, lanolin and cationic surface-active components.

Coating finish : A soft film. Will never dry out.


Toxicity : Non-toxic. However the product should not be used for
drinking water tanks, as it may affect the taste and smell
of the water.
Shelf life/ stability : Indefinite
Cleaning of utensils : The coating can be removed by most solvent based cleaners,
e.g. Careclean HD split.
Specific gravity (at 20°C) : 0,94
Flash point (10%) : 122°C (251°F)
Viscosity : 30 mPa.s/50°C
Solid contents : 100%

For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Watertreatment -
CARETREAT 1 EVAPORATOR

Neutral, liquid product for the prevention of scaling in sea water evaporators

* Product developed as part of the Marine Care Water Treatment Program.


* Prevents scale formation at temperatures up to 160° C.
* Reduces foaming and maintains optimum plant performance.
* Environmentally safe product with approval for use when distilling to potable water tanks.

Introduction

In the production of distilled water in seawater evaporators, there are many conditions which can
cause scaling. In the evaporator, the seawater is heated to the required temperature and is then
partially evaporated at atmospheric or low pressure; it then condenses and is collected as distillate.
Since, however, the seawater contains large quantities of salt in solution it is understandable that the
heating and evaporation will very rapidly lead to scaling of the heat transfer surfaces. The scale
deposits build up and lower plant efficiency by severely impairing the transfer of heat. This in turn
considerably reduces the output. Scaling is prevented by the use of Caretreat 1 Evaporator.

If the product is used as part of the Marine Care Water Treatment program, production is monitored
as part of a "Water Management" system which includes useful information on maximizing plant
efficiency.

Directions for use

Caretreat 1 Evaporator is diluted with seawater andfresh water and is continuously injected into the
evaporator. A dosage of 30 ml per ton of distillate is recommended for the prevention of scaling in
seawater evaporators. The total dosage of Caretreat 1 Evaporator to be used depends on the capacity
and the operating conditions of the evaporator. The product should be injected via the evaporator
inlet or the salt water supply line. The normal procedure is to use a dosing tank containing sufficient
ready diluted Caretreat 1 Evaporator for 24 hours continuous operation.

Note: For the gradual removal of existing scale deposits, at least twice the normal dose must be used.
Remove deposits of more than 2mm, with Careclean HD Descalex L.
Dosing systems

Marine Care can supply a gravity dosing system kit which includes a dosing tank, flow meter, pipes,
valves and all fittings.

Properties

Light brown colored, neutral liquids. Miscible with salt and fresh water in any proportion.
Odorless, non-flammable.
Contains no volatile components; in practical terms, non-toxic when ingested in a single dose.
Remains fully effectively up to 160o C.
Does not corrode stainless steel, carbon steel, copper alloys, glass rubber, plastics, painted surfaces,
aluminium and aluminium alloys.

Specific gravity (20oC) : 1.10


Flash point : None
pH (1% solution) :7

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT 2 DIESEL

Diesel engine cooling water corrosion and scale inhibitor in liquid form, suitable for "closed
circuit" systems

* One of the five Marine Care Water Treatment Products.


* Suitable for slow, medium and high speed engines.
* Effective inhibition of ferrous and non ferrous metals.
* Prevents scale and sludge build ups.
* Safe to use when cooling water is heat source for potable water systems.
* Has approval of major diesel engine manufacturers.
* Does not encourage bacteria in system.
* If the chloride level is below 100 ppm CI, also aluminium in normal rated engines is
protected.

Application

Caretreat 2 Diesel is a nitrite, borate and polymer based corrosion inhibitor with a suitable buffer to
ensure stable pH conditions. The formula has the U.K. Department of Trade approval for use in
cooling systems incorporating a fresh water generator producing fresh water for drinking purposes.

Recommendations for cooling water treated with Caretreat 2 Diesel :


Nitrite 1200-3000 ppm NO2
Chloride max. 100 ppm CI
Hardness max. 180 ppm CaCO3
pH 9,0 - 10,0

Directions for use

Caretreat 2 Diesel is used in a dosage of 1200 - 3000 mg/l nitrite (NO2), dependent on the chloride
level and engine type, please refer to the engine manufacturers instructions on recommended nitrite
ranges:

Chloride concentration Initial dosage Nitrite range


0 - 50 ppm CI 6 ltr/m3 cooling water -1500 ppm NO2
50 - 100 ppm CI 6-8 ltr/m3 cooling water 1600-2000 ppm NO2
Starting with the treatment of a system, the nitrite level must be kept at the higher nitrite level of
the corresponding chloride concentration by testing and dosing daily. If the system is passified the
testing frequency and dosing can be reduced till once a week at minimum. Always add Caretreat 2
Diesel at a point where circulation is high. Most modern systems header tanks are purely for
expansion and have little or no circulation. Also they are often fitted with an internal baffle which
can have the effect of trapping treatment and subsequent difficulty in obtaining the correct levels.
The majority of loss in treatment levels will be due to leakage and subsequent dilution by make up
water (distilled water should always be used). We advise testing of the Caretreat 2 Diesel level
with the Marine Care nitrite control test, or via the conductivity with the BWT Electronic testkit.

Dosing system
A compact electronic dosing pump and tank unit is available from Marine Care for direct injection
to the cooling system. For further details refer to Marine Care equipment information.

Remarks
On new buildings or overhauled systems, follow engine manufacturer's advice in conjunction with
Marine Care. If changing to Caretreat 2 Diesel from nitrite borate based products of another make,
start dosing Marine Care product using Marine Care tests. Caretreat 2 Diesel will slowly remove
sludge and other residues during first month. This can result in slightly cloudy water which will
clarify after draining small quantities of water and as make up is added, leaving system extremely
clean. It is not necessary to drain existing coolant completely unless inspection has shown
excessive contamination. Marine Care can give expert advice on cleaning systems.

Properties

Caretreat 2 Diesel is a pale yellow liquid, completly soluble in water. It is based on nitrite and
borate in combination with specific inhibitors, organic dispersants and a pH buffer. Compatible
with anti-freeze products based on monoethylene glycol.

Specific gravity (20oC) : 1.225


pH (1% - solution) : 9,5 - 10
Flash point : none

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
COOLING WATER TREATMENT TEST (CARETREAT 2 DIESEL)

TEST TEST METHOD DOSAGE (LTR/ TON)

NITRITE 1. Completely rinse the dropper to be used, then fill the dropper to the 0.5ml mark * INITIAL DOSAGE: 6 LTR/TON (NORMAL RATED)
with the sample and discharge into color viewing tube.
* LIMIT: 2. Fill the tube to the upper mark (=10ml) with demineralized water. 1. Normal rated engine
3. Divide the diluted sample equally between the color viewing tubes (each) 5ml.
1. NORMAL RATE Add 1Nitriver 2 reagent powder pillow to one of the tubes, and stopper & mix PPM DOSAGE
1200-2000ppm well. If nitrite is present a greenisch/brown color will develop. Allow 10 min. 200 5.3 ltr
2. HIGH RATE for HIGH 4. Place the tube prepared with Nitriver 2 in the right position of comparator, and 400 4.5 ltr
SPEED ENGINE: the other tube place to the left. 600 3.8 ltr
2500-3000ppm Rotating disc of comparator until a color match is obtained. 800 3.0 ltr
1000 2.3 ltr
** SCALE READING x 20 = PPM AMOUNT 1200 1.5 ltr

** PH: 9-10

CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. UP TO 100PPM: SATISFACTORY
Pour the contents of the tube into the mixing bottle.
(Limit: up to 100ppm) 2. Fill the bottle with distilled water up to 15ml Over 100PPM: Partly drain and dose Caretreat 2 Diesel
3. Add 1 Chloride 2 indicator powder pillow and mix well. accordingly.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color

Amount of drops x 30 = Chloride PPM

*** TEST KIT 1. TEST SET FOR NITRITE 2. CHLORIDE TEST KIT 3. PH PAPER ***
DIESEL ENGINE COOLING WATER GRAPHIC LOG

M.F. Make and type: Cooling capacity: m3 Aux Engines: m3 Capacity: m3

Chlorides ppm Cl 30 60 90 120 Nitrite (Plot as X) pH Caretreat 2 Make


OK Medium High Excess 1200 1600 2000 2400 2800 ppm NO2 Diesel - added up feed
8.0 8.5 9.0 9.5 10 (Ltr.) added (ltr.)

Date: M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

Nitrate Level Main Engine: ** To increase Care 2 level by 100 ppm NO2 add 0,4 Ltr/ M3 Submitted by:
Between 1200 - 2000 PPM NO2
Nitrate Level Aux. Engine: Remarks: Approved by
Between 2500 - 3000 PPM NO2 Ch. Engineer
CARETREAT 3 BOILER

Advanced organic boiler water treatment to control ph, corrosion, scale and sludge.

* One of the five Marine Care Water Treatment Program Products.


* Advanced polymer technology.
* Organic corrosion control.
* Simple accurate testing.
* Prevents caustic corrosion.
* Low "Totally Dissolved Solids".
* Effective scavening of nominal oxygen prescence.

Introduction

Caretreat 3 Boiler has been developed to meet the demands for a modern, practical boiler water
treatment. Caretreat 3 Boiler is a dark brown liquid based on neutralized organic acids, pH, corrosion,
scale and sludge conditioners.

The neutralized organic acids remove nominal oxygen presence and inhibit the boiler corrosion forming
an organic iron compound. The correct pH is maintained by a unique blend of low molecular weight
compounds which avoid pitting corrosion caused by chlorides. Use of these compounds also avoids
"under deposit" corrosion which is caused by excess alkalinity in conventional treatment.
A blend of advanced polymers stops the formation of scale and maintains clean surfaces in the boiler.
These conditions are maintained with a low total solids level, avoiding heavy sludge, making blow
down of the boiler more efficient.

Application

Marine Care Water Treatment Program


Suitable for all auxiliary boiler plants on motorships including dual pressure boiler primary systems of
up to 50 Bar.

Standard Water Treatment


This program is suitable for boilers up to 20 bar, results we strongly recommend continuous dosage into
the feed system, via a dosing pump and tank unit.

Directions for use


Marine Care Water Treatment Program
If the product is used as part of the Marine Care Water Treatment Program, it must be continuously
dosed in conjunction with Caretreat 4 Condensate using the Marine Care dosing pump / tank unit.
For further details on dosing equipment refer to equipment information sheet.

Standard Water Treatment


Caretreat 3 Boiler can be added directly to the feed water. We strongly recommend this and this is
achieved by using a dosing pump.

Control limits

Standard Water Treatment


The boiler water must meet the following conditions:

p-Alkalinity : 100-200 ppm CaCO3


Chloride content : max. 200 ppm Cl
pH : 10.5 to 11.0
Conductivity : 400 to 2000 uMho

Intial dosage
Caretreat 3 Boiler is dosed at 0,4 litres per metric ton boiler water. Allow the boiler water to be
conditioned for 24 hours and then carry out a p-alkalinity test. Adjust product dosage as necessary to
obtain a p-alkalinity of 100 - 200 ppm.
At the same time determine the chloride content. If the chlorides are too high, give the boiler a top and
bottom blow down in a ratio in time 2 to 1.

Daily dosage
Recheck p-alkalinity and increase dosage of Caretreat 3 Boiler if necessary to maintain pH or p-
alkalinity level. A minimum of 0,2 ltr/day should be dosed to maintain correct treatment levels in
conjunction with regular top and bottom blown down. This dosage can vary according eg. size of the
boiler system, make up water quality etc.

Properties

Caretreat 3 Boiler is a dark brown liquid containing neutralized organic acids, pH, corrosion, scale and
sludge conditioners. After using the treatment the boiler water will be clear and straw coloured.
Specific gravity : 1.21 (20o C)
Flash point PM CC : None
pH (1 % solution) : 13

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
BOILER WATER TREATMENT TEST (CARETREAT 3 BOILER & CARETREAT 4 CONDENSATE)

TEST TEST METHOD DOSAGE

P-ALKALINITY 1. Completely fill the plastic measuring tube with boiler water. ** CARETREAT 3 BOILER **
Pour the contents of the tube into the mixing bottle.
* (Limit: 100-200ppm) 2. Fill the bottle with distilled water up to 15ml * Initial dosage: 0.75 ltr/ ton
3. Add 1 phenolphtalein indicator powder pillow to the mixing bottle and mix
4. A pink color will appear (if colorless, P-Alkalinity is zero). * Over 200ppm p-Alkalinity - decrease dosage by 25%
Add drop by drop sulphuric acid standard solution counting the number of drops, * p-Alkalinity level between 100-200ppm - satisfactory.
untill the solutions is colorless. * Below 100ppm p-Alkalinity - increase dosage by 25%

Drop: 0 3 6 9 12 ** pH: 10-11,5


PPM: 0 50 100 150 200

CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. *Up to 200ppm: satisfactory
Pour the contents of the tube into the mixing bottle.
* (Limit: up to 300ppm) 2. Fill the bottle with distilled water up to 15ml * Over 200ppm: blowdown
3. Add 1 Chloride 2 indicator powder pillow and mix well.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color

Amount of drops x 30 = Chloride PPM

CONDENSATE PH 1. Take condensate water sample, and immerse pH paper. ** CARETREAT 4 CONDENSATE **
2. Read the pH value..
* (Limit: pH 9-9.5) * Initial dosage: 0.2 ltr/ ton
* 0.4 ltr/ 24 hours - normal daily dosage

*** TEST KIT 1. TEST SET FOR P-ALKALINITY 2. CHLORIDE TEST KIT 3. PH PAPER ***
BOILER WATER GRAPHIC LOG

Date:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

P. ALKALINITY / ppm CaCo3

350
300
250 Decrease Dosage 10%
200
150 Ideal
100
50 Increase Dosage 25%
0

CHLORIDES / ppm C1

210
180
150
120
90
60
30
0

CARETREAT 3 BOILER - DOSAGE (LTRS.)


2.0
1.5 Month
1.0 Total
0.5
0 ltrs
Maintain min. Dosage 0.2 LTR. / 24 HRS

CONDENSATE / pH
10.0 Decrease Care 4 Dosage 10%
9.5 Ideal
9.0
8.5 Increase Care 4 Dosage 25%

CARETREAT 4 CONDENSATE - DOSAGE (LTRS.)


2.0
1.5 Month
1.0 Total
0.5
0 ltrs
Maintain Minimum Dosage 0,4 Ltr. / 24 Hrs.

Vessel name: Remarks:


Month:
Year:
Boiler Type:
Pressure: bar Submitted by:
CARETREAT 4 CONDENSATE

An organic oxygen scavenger and corrosion inhibitor for feed, steam and condensate systems

* One of the five Marine Care Water Treatment Program Products.


* Environmentally safe, non-toxic product.
* Unique single product for control of corrosion throughout the condensate system.
* Simple, accurate testing.
* Effective under all operating conditions.
* Protects boiler surfaces by forming an iron tannate film.

Introduction

Caretreat 4 Condensate is an oxygen scavenger based on neutralized organic acids and a blend of
volatile/neutralizing amines. It is normally used only in conjunction with Caretreat 3 Boiler as part of
the water treatment program. It removes oxygen efficiently in open feed systems and gives effective
corrosion inhibition of boiler/exhaust gas economizer system surfaces by converting Fe203 (rust) to an
organic iron compound. It also protects copper based metals. The amines pass over with the steam and
have the dual function of elevating the pH of the steam/condensate and putting a protective micro film
on the system pipe work. Acidic condensate is the result of carbonic acid (H2C03) being formed as CO2
is released in the steam. The use of Caretreat 4 Condensate prevents corrosion by carbonic acid on live
systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are
present.

Directions for use

Caretreat 4 Condensate is dosed at a rate which maintains a pH of 9.0 to 10.0 in the condensate returns.
Oxygen entrainment largely depends on Hotwell temperatures and if these are maintained at above 80o
C the condensate pH range of pH 9.0 to 9.5 is adequate. If Hotwell temperature control is erratic and
averages less than 80o C, tighter control is necessary and condensate returns should be kept in the range
pH 9.5 to 10.0. It is not necessary to carry out oxygen or product residual tests.

Initial dosage
Caretreat 4 Condensate is initially dosed at 0,2 ltr/m3 boiler water. Systems showing signs of corrosion
should be dosed at up to .07 ltr/m3 boiler water for the first few days in order to passivate all metal
surfaces.
Daily dosage rates
After initial dose, start metering at a minimum of 0.4 ltr/24 hours continuously and adjust to obtain
correct condensate pH.

Dosing system
Caretreat 4 Condensate must be dosed continuously in conjunction with Caretreat 3 Boiler in a
metering pump/tank unit, discharging directly into the feed system and/or the exhaust gas economizer
circulating pump discharge. It must NEVER be slug dosed to a running system via a Hotwell or by-pass
feeder. For further details on dosing equipment refer to the equipment information sheets.

Properties

Brown aqueous solution of neutralized organic acids and amines.

Specific gravity (20oC) : 1.05


Flashpoint PM CC : none
pH (1% solution) : 10.8

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT 5 SEAWATER

Disperses marine growth and reduces corrosion in sea water cooling systems, tanks and sea
water systems

* Prevents and controls marine growth in once-through sea water cooling systems.
* Protects system from corrosion by filming properties.
* Being biodegradable and not oil-based, its use does not contravene regulations limiting oil in
discharge water.
* The formula is approved by the U.K. Department of the Envirement for use at a dose rate not
exceeding 8 ppm for sea water pipelines feeding evaporators producing water for potable
purpose
* Has clearance of major international environmental control departments for discharge into
harbour and sea.
* Empty tanks remain protected for several days.

Introduction

Caretreat 5 Seawater has been designed to effectively stop the development of micro organisms, shell
embryo, bacteria and plant life commonly found in sea water. Most fouling of ships systems is
primarily the result of microscopic organisms colonising in the pipework, attracting growth of larger
lifeforms and giving anchorage to sand and silt. Partial blockage of heat exchanger tubes reduces flow,
resulting in local overheating and subsequent scaling from hardness salts.

Directions for use

1. Sea water cooling systems


The product is injected into seachests to give a concentration of 6 ppm over a period of 1 hour every
two days that the vessel is in shallow water. This period is sufficient to remove the foulants before they
have anchored and started adult development, at which time they are extremely difficult to control. To
achieve these dosing rates, 0,6 litre of Caretreat 5 Seawater must be injected each second day for each
100 tons/h of flow into the seachest(s) (=0.006 litre/ton). Vessels which are continuously coastal must
inject Caretreat 5 Seawater at he same rates every third day.

Dosage instructions
Example : system of 250 tons/h.
Dosage method
Using the Caretreat 5 Seawater Dosing System to high and low boxes via stop valve and non-return
valve. Extension tube mounted inside box, out to grid. For further details refer to the Marine Care
equipment information sheet.

Dosage routine
A. Calculate amount of Caretreat 5 Seawater for each dose. i.e. 250 tons per hour x 0.006 litre =
1.5 litres/dose.
B. If using a dosing system which requires dilution of Caretreat 5 Seawater with water never add
water to the product. Always mix the product into the water, stirring continuously.
C. On approaching shelf or coastal area, open discharge valves to operating chest and operate
system for 1 hour.
D. Close system valves.
E. Make note of date and which box dosed.
F. If changing to high level suction remember to dose to the correct box.
G. When leaving area (dockside, estuary, coast or shelf area) continue dosing on 2 day cycle so
that last dose is after clearing shallow waters.

2. Tanks
Inject Caretreat 5 Seawater into sea water at 45 - 130 ml per m3 water capacity.

3. Pipelines
Dose at 100 ppm by injecting 80 x D-ltrs per kilometer of pipeline. (D = pipe diameter, in meters).
If fresh water is used for either applicaion lower concentrations may be used.

Properties

Cloudy yellowish-brown aqueous liquid containing dispersants with filming properties. In concentrati-
ons less than 10 % miscible with water.

Specific gravity (20oC) : 0.99


Flash point PM CC : above 100oC
pH (1 % solution) : approx. 7

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT POTABLE WATER TREATMENT

• Prevents corrosion in potable water systems


• Prevents rusty appearance of water
• Stabilises excess hardness
• Economical, easy to dose liquid
• NON toxic (less than 10 ppm SiO2)

INTRODUCTION

Caretreat Potable Water utilises polymer technology in


combination with silica to provide a protective film on system surfaces, avoiding corrosion
and scale formation.
The product can be injected into the discharge lines of the fresh water generator and/or
reverse osmosis plant to avoid the problems of corrosion caused by the acidic distillate from
these plants. If these lines are protected, the product is injected directly into the fresh water
pumps’suction manifold. If a high percentage of shore water is used and the tanks are
oxidising, the product must be slug dosed into the tanks prior to taking water.

APPLICATION

Dosage instructions

Initial dosage:
Inject the product at a rate of 50 ml. per m3 water.
Use the same rate (50 ml/m3 water) for slug dosing tanks.

Continuing dosage:
Within a short period water outlets on the vessel will become clear.
At this time, reduce the dosage to 25 ml. per m3 water.

Dosing system operation:


To achieve the initial 50 ml/m3 water the following routine must be carried out :

a. Calculate average daily potable water consumption


from vessel records.
b. Using rate for initial dose (50 ml/m3 water) calculate
24 hours requirement.
c. Partly fill dosing tank with water and add the
calculated volume of product, for each 24 hours of
injection.
d. Fill the tank to capacity, mix well and start dosing.
Example:

For 20m3 per day : initial dose


Pump : PWT dosing unit
Max. output : 10 litres/hr.
Tank capacity : 60 litres

Dilution of product : 60 : 1

* Add 1 litre of POTABLE WATER


* Fill the tank to capacity (60 litres)
* Set pump stroke and cycles to discharge 60 litres/day
* Refill every day.

For further details on dosing units refer to the equipment information sheets.

PROPERTIES

Aqueous colourless liquid. Completely miscible with water.


Specific gravity (20° C) : 1.233
Flash point : none
pH (1% solution) : 10.4
IMO-Code : no classification.

NATURE OF SPECIAL RISKS AND SAFETY REGULATIONS

In accordance with the latest E.E.C. Council directives this product is not subject to any
official recommendations.

Voluntary Marine Care recommendation


Irritates the skin. In case of contact with eyes, rinse immediately with plenty of water and
seek medical advice.

The details of our products are given completely free of undertaking. Since their application
lies outside our control we cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Fuel Oil Treatment -


CARETREAT SLUDGE

Caretreat Sludge is an oil soluble and self dispersing fuel oil treatment primarily
formulated to combat problems in the pre-combustion stage with oil used in marine
diesel engines and boiler plants.

• Dissolves and disperses existing sludge. Dispersants maintain the combustible


constituents in suspension throughout the oil.
• Prevents polymerization and inhibits asphaltenic sludge formation and paraffin wax
separation resulting in less clogging of fuel filters and fuel injector fouling.
• By dispersion of sludge, Caretreat Sludge will counteract the effects of stratification
(layering) of incompatible fuels, thereby promoting a homogenous uniform viscosity.
• Will break water/ oil emulsions and promote separation of dispersed water from heavy
fuel oil, thereby improving purifier efficiency.
• Corrosion in tanks and fuel lines is reduced by effective corrosion inhibitor
incorporated.
• Improved conditions in the pre-combustion stage will result in an improvement of
some post combustion problems such as a more complete combustion, less carbon
formation, a decrease in deposit forming sodium, less smoke and soot.

Application

Caretreat Sludge is easy to use. The required amount is introduced into the bunker tanks
simply by pumping it through the sounding pipes prior to oil bunkering. The turbulence
created by the subsequent bunkering will, together with the incorporated dispersants, ensure
complete mixing and further distribution of the treatment uniformly throughout the fuel.

Dosages
To obtain the benefits of the chemical treatment to the entire fuel oil system it is necessary to
dose the product in the most appropriate ratio depending upon the nature and severity of the
problem.

If Caretreat Sludge is not used regularly an initial dosage of 1:4000 should be used for
breaking up and dispersing existing sludge. For counteracting the effects of incompatible fuels
(stratification) a dosage as high as 1:2000 may be necessary.

Properties

Clear yellow liquid with a characteristic smell, containing solvents, special detergents and
dispersants. Contains no chlorinated solvents or other harmful ingredients.
Specific gravity (20%) : 0.86
Flash point PMCC : over 62°C
Viscosity : approx. 10mPas

Storage
Maximum storage temperature : + 50°C
Minimum storage temperature : - 20°C

For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARETREAT COMBUSTION

The latest development of a fuel oil treatment acting as a combustion improver, carbon
catalyst, ash deposits modifier and smoke suppressant for diesel engines and boilers.

* Increases combustion efficiency.


* Reduces carbon buildup effectively in combustion zones.
* Inhibits the formation of carbonaceous ash deposits in exhaust and scavenging ports.
* Minimising low temperature corrosion by effective catalysts inhibiting conversion of
sulphur dioxide to sulphur trioxide.
* Reduces piston ring groove and piston fouling resulting in longer life of piston rings and
cylinder liners.
* Reduces ash deposit formation in turbo-chargers and on exhaust valves.
* Decreases smoke emissions.
* Fuel conditioning components stabilizes fuel viscosity, preventing sludge formation in
tanks, filters, preheaters.
* Improves water separation in settling tanks and separators.

Application

Caretreat Combustion is a concentrated product, especially formulated to treat heavy fuel oil in
diesel engines and boilers.

Dosing
Dosage point location varies depending on engine/boiler fuel system layout. The most efficient
and economical method is obtained with a metering pump, dosing the additive into the suction
side of the booster pump (for diesel engines) or into the burner feed line (for boilers).
Alternatively the additive may be dosed directly to the day tank prior to refilling or directly to
the bunker tanks.
Dosage rates are depending upon engine characteristics, operating conditions and quality of
fuel oil. A CCAI (Calculated Carbon Aromaticity Index) number exceeding 840 indicated a
poor fuel oil quality which justifies the use of a chemical fuel oil treatment to counteract the
effects hereof.
Typical dosage rate varies between 1:1000, 1:6000 and 1:12000. Consult your local Marine
Care Service Engineer for recommendations of the dosage rate based on specific problems and
requirements onboard.
Properties

Browns liquid containing special solvents, emulsion breakers, anti-oxidants, anti-corrosive


agent, combustion catalysts, inhibitors, dispersants and ash modifiers. It is easily soluble in all
types of fuel.

Flash Point PM CC : approx. 80 °C


Specific Gravity (20°C) : approx. 0,9

For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT ECONOMIZER

Liquid to prevent soot deposits in exhaust gas boilers at low temperature.

* Effective above 200 °C


* An easily dosed liquid
* Complete coverage of entire exhaust gas unit
* Greatly improved heat transfer
* Neutralises sulphuric acid
* Reduces corrosion and fire risk

Introduction

Todays main propulsion units have low exhaust gas outlet temperatures. This is due to increased
engine and turbo blower efficiency. Lower gas temperatures are also the result of running at
reduced power. The low temperature and reduced gas volume gives increased soot deposition
and subsequent corrosion.
The increased deposition greatly reduces the thermal efficiency of the economizer. As "dew
point" is often reached in the unit, causing the generation of sulphuric acid, the corrosion process
is greatly accelerated.

Caretreat Economizer is a specially developed liquid which is easily dosed into the system, using
a special Marine Care injection unit. The special air assisted nozzles create a fine mist so that the
liquid vaporises on contact with the hot gas.
The vapor mixes intimately with the exhaust gases and the active material is dispersed
throughout the system in microscopic particles. These tiny particles have an extremely large
"active surface area" and being light, remain in the gas fully dispersed. This ensures that all parts
of the economiser are covered efficiently.

Caretreat Economizer catalyses the post combustion process, resulting in modified soot particles
which are dry and non adherent. The resulting deposit is more friable and can be more easily
removed by the action of the sootblowers.

Directions for use


Caretreat Economizer is designed to prevent major build ups of soot in service.

Dosage instruction
1-2 litres of Economizer is required for every 1000 m2 of heating surface area. This amount
should be increased / decreased dependant on economizer design and fuel consumption.
Dosage period
Caretreat Economizer should be injected daily or twice daily after sootblowing.

Dosing equipment
The product must be dosed via the specially developed Marine Care injection unit which is made
of materials suitable for prolonged contact with Caretreat Economizer. For further information
please refer to the Marine Care equipment information sheet.

Injection points
In most cases a single injector can be put into the exhaust systems immediately after the turbo
charger gas outlet. Marine Care engineers will inspect and make detailed recommendations for
exact positioning.

Properties

Yellowish coloured neutral product containing special metal salts. Fully miscible with water.

Specific gravity (20°C) : approx. 1.19 kg/ltr.


Flash point : none
pH (1% solution) : approx. 7

For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARETREAT VALVES

A Post-Combustion fuel ash modifier very efficiently reducing high temperature


corrosion causing premature exhaust valve failure in low-speed and particularly
medium-speed diesels

* Reduces deposits caused by combinations of sodium, vanadium and sulphur in


combustion zones, turbochargers and especially on exhaust valve seats and valve
stems.
* Increasing exhaust valve life substantially.
* Raising fuel ash sinter and melting point temperatures above the normal engine
operating temperatures.
* Reduces turbocharger fouling.
* Reduces high temperatures fused salt corrosion of valve alloys.
* Modifying vanadium compounds to non-adherent ash forms.
* Converts crystalline ash forms to light and friable, easily exhausted fuel ash.
* Prevents vanadium from converting sulphur dioxide to sulphur trioxide catalytically.
* Improves combustion.

Application

Caretreat Valves has been formulated primarily for use in 2-cycle and 4-cycle medium
speed diesel engines which are highly turbocharged and in which premature exhaust valve
failure is a frequent problem.

Dosage
Dosage point location varies depending on engine fuel system layout. The most efficient
and economical dosing method is obtained with a metering pump, dosing the additive as
near to the oil injection point as possible, f.inst. to the suction side of the booster pump.

Dosage rates are depending upon engine characteristics, operating conditions and
especially the quality of fuel oil. Consult your local Marine Care Service Engineer for
recommendation of dosage, etc. based on specific problems and requirements onboard.
Guide for approximate dosage rates:

Constituent Level Dosage Rates

Conradson Carbon 5% 1:7000


up to: 5% - 10% 1:5000
10% - 15% 1:4000
15% and up 1:3000
Sodium up to 20 ppm 1:8000
20-30 ppm 1:6000
30 ppm and up 1:4000
Sulphur up to 2% 1:8000
2% - 3% 1:4000
3% - 4% 1:3000
4% and up 1:2000
Vanadium up to 200 ppm 1:6000
200 - 300 ppm 1:5000
300 - 400 ppm 1:3000
400 ppm and up 1:2000

The combination between the various constituents changes with each bunker supply. It is
therefore imperative that dosages are set for the worst case, viz. the highest value of any of
the above fuel oil
constituents.

Properties

Caretreat Valves is a light brown coloured liquid containing oil soluble organo-metallic
compounds, special solvents, emulsion breakers, anti-oxidants, anti-corrosive agents,
combustion catalyst and dispersants. Compatible with all types of fuel oil.

Specific Gravity (20°c) : 0.835


Flash Point PM CC : 63°C
IMO Class : 9-3082-T310

NATURE OF SPECIAL RISKS AND SAFETY ADVICE

In accordance with the latest E.E.C. Council directives this product is not subjected to any
official recommendations.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARETREAT SOOT

Vapourising powder for the reduction of deposition and corrosion in boilers.

* Modifies soot making it less adherent.


* Reacts with sulphur, avoiding sulphuric acid formation.
* Reduces vanadium slagging.
* Enhances soot blowing.
* Reduces fire risk in uptakes.

APPLICATION

Caretreat Soot is suitable for all types of oil fired boilers.


It is injected into the combustion chamber and vaporises. The vapor mixes with the combustion
gases and reacts with sulphur oxides, which remain as sulphur dioxide (SO2) instead of sulphur
trioxide (SO3) which normally combines with water (H2SO4).

The modified sulphur oxides combine with vanadium compounds and prevent the formation of
harmful low melting point sodium vanadyl vanadates.
Caretreat Soot greatly improves sootblowing efficiency and makes boiler cleaning an easier task.

DIRECTIONS FOR USE

Dosage
Initial dosage for dirty boilers should start at 130 gr. per m³ fuel burnt in 24 hours.
The calculated dose should be divided into 3 equal parts and dosed at 8 hour intervals. As
conditions improve the dosage can be progressively reduced to a minimum of 30 gr. per m³ fuel
burnt in 24 hours.

Once every 24 hours soot should be blown at least 1 hour after the last injection of Caretreat
Soot.

If a boiler has never been treated and is very dirty, double the initial figures can be used for the
first 2 weeks.

Injection
An air operated powder injector can be supplied by Marine Care. Its discharge tube should be put
through a combustion chamber sighting orifice or a special dosing access point. If possible, the
injection should be changed frequently to assist distribution throughout the boiler.
PROPERTIES

A blue, neutral powder with a sublimation point of 350°C.

Flash point : none


pH (1% solution) : approx. 7
Storage : keep cool and dry.

For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Tank Cleaning Chemicals -


CARETANK ECO
Heavy Duty Tankcleaner – Emulsifier

HEAVY DUTY TANKCLEANER MANUFACTURED FROM NATURAL RAW MATERIALS


WHICH CONTAINS NO CHLORINATED OR AROMATIC HYDROCARBONS

• More effective than solvent cleaners.


• Non-toxic and environmentally safe.
• Safe to use because of its high flashpoint.
• Completely biodegradable.
• Replaces most conventional tankcleaners.

Application

Caretank ECO is designed for the removal of: heavy mineral oils and greases, dopes, additives, lubricants,
asphalt, distillation residues, coal tar, several synthetic resins, paraffines (e.g. slackwax), inert gas soot,
vegetable-, fish- and animal oils and fats, fatty acid and greases, crude palm oil, styrene, palm fatty acids.

Directions of use

Cleaning of cargo and storage tanks by means of recirculation method.

Prewash
Before cleaning with Caretank ECO, it is necessary to prewash the tanks with hot or cold water, depending
on the type of cargo.

Recirculation method

Caretank ECO is added to a mixing tank containing sufficient quantity of water in order to obtain a good
recirculation.
The water is heated by means of the heating coils, cargo heat exchanger or butterworth heater.

The tanks are washed by means of a loading pump, after which the solution used is recycled to the mixing
tank. One solution is most often used to wash 1 – 4 tanks.
Caretank ECO must be recirculated as a 0.2 – 0.5 % emulsion (dependent on the nature of the
contamination). Allow this emulsion to circulate for 2 – 4 hours at the temperature of 10-60 °C (depending
on type of cargo).

Direct Injection

Inject 0.1 to 0.2 litres of Caretank ECO per every 100 litres of water into the washing system.
Maintain cleaning temperatures between 10-60 °C (depending on type of cargo).
Cleaning time 2 to 6 hours, followed by thorough rinsing with fresh hot water.

Properties

Specific gravity (at 20°C) : 0.94


Flash point (10%) : ± 70 °C
pH (10%) : 10.0
Colour : green
Odour : citrus

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ALKALINE

Powerful non-caustic alkaline cleaner

• Removes vegetable and animal oils, fatty acid and greases, whether or not hardened or
carbonised.
• Applicable at low temperatures.
• Works effectively.

Application

Careclean Alkaline contains besides non-ionogene surface-active components and alkaline salts
even effective solvents. This makes the products well applicable at lower temperatures (20-60oC)
by means of some circulation. Careclean Alkaline is suited to remove vegetable and animal oils
and greases, whether or not hardened or coarbonised. Careclean Alkaline is not suited to use on
zinc silicate coatings and most paints/laquers. Diluted with water to a solution of maxium 10%
and at a temperature of maximum 60oC, the product is safe to use on epoxy-coatings. It is suited to
use on most metals except for aluminium, tin, zinc and galvanised material.

Directions for use

Prewashing
Prior to cleaning with Careclean Alkaline, it is advised to wash with hot water of approximately
80oC. In case of drying and semi-drying oils, prewashing is to be done with cold water.

Immersion bath
For slight oil-contaminations Careclean Alkaline can be diluted with water to a 10% solution.
Heaten the liquid with a heating coil or by means of steam injection to 20-60oC. Place the objects
to be cleaned in the bath and allow several hours working time. Afterwards brush the objects while
rinsing them with a powerful waterjet. In case of heavily contaminated objects, Careclean Alkaline
is applied undiluted in immersion bathes, for example to remove old paint layers to and to clean
oil and grease filters, deep fry equipment, baking ovens etc.

Spraying
Depending on the amount and character of the contamination, Careclean Alkaline is to be used
pure or diluted at a temperature of 20 - 60oC. Allow the product to work for 20 to 60 minutes and
spray afterwards with a powerful high pressure waterjet. Warm water is to be preferred.
Recirculation
With this method, the cleaning chemicals are added to a prior determined amount of cleaning
chemicals is usually 1% of the capacity of the tank is to be cleaned.

Properties

Light brown liquid. Very alkaline, contains potassium hydroxide. Suited to use on most metals,
but is not to be used on tin, aluminium, zinc silicate coatings.

Specific Gravity (20oC) : 1.06


Flash point (PMCC) : 98oC
pH (1% Solution) : 12.5

Contains approximately 7% potassium hydroxide.

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN ALKALINE EXTRA

Strong alkaline liquid degreasing agent for the removal of vegetable, fish and animal oils and
fats from epoxy / polyurethane coated or stainless steel tanks by injection or circulation
method.

* Very powerful alkaline cleaning agent based on strong anionic surface active agents and
alkaline salts.
* Thorough saponification and emulsification provides economic removal of vegetable and
animal oils.
* Can be used on most common metals except aluminium, tin, zinc and galvanised metals.
* Safe to use on epoxy and polyurethane coatings but it is not suitable for use on zinc silicate
coatings, most paints and lacquers (For zinc silicate coating we advice the use of Careclean
Neutral HCF).
* Deodorises certain residues.

Application

Steam boilers
Prior to acid cleaning of steam boilers which are also contaminated with oil and grease or when
silicates/calcium sulfates are present it is advantageous to first perform a boil out operation with
Careclean Alkaline Extra.

Tanks
Suitable for the removal of fatty acids, fish oils and other drying or semi drying oil deposits present
as deposits in storage and loading tanks. It is very effective on dried oil films. When cleaning from
"black" to "white" and from "black" to grain it is a useful final treatment.

Directions for use

Cleaning of steam boilers


Fill the boiler with a 5-10% solution of Careclean Alkaline Extra in water. Depending on the degree
of contamination allow this solution to circulate for 12 to 24 hours at a temperature of 80°C. After
this boil out operation completely drain away the warm cleaning liquid and rinse the boiler
intensively with cold water.

Tank recirculation method


Careclean Alkaline Extra is added to a mixing tank containing a water quantity of 1% of the
capacity of the tank to be cleaned. The solution is heated by using the heating coils in the tanks. The
tanks are washed by using a cargo pump after which the solution is recycled to the mixing tanks.
Usually one solution can be used to wash 2-3 tanks. Careclean Alkaline Extra is circulated as a 1-3%
solution at 80-90°C for a period of 2-6 hours. After circulation rinse thoroughly with water.

Direct injection method


Inject 1-2 litres of Careclean Alkaline Extra per 100 litres of wash water directly into the tank
washing system. The recommended cleaning temperature is 80°C. When completed rinse thoroughly
with water.

Closing remarks regarding rinsing


In many cases an after treatment with Careclean Rust solution is recommended for the removal of
white lime deposits originating from sea water and/or residues out of the cargo. Inject 0.5 litre
Careclean Rust per 100 litres of wash water directly into the tank washing system for approx. 20
minutes. The recommended temperature is 75-85 °C. Finally wash the tanks thoroughly with cold
fresh water.

For detailed instruction on tankcleaning refer to the Careclean Tank Cleaning Manual.
A range of support equipment is also available.

Properties

Strong Alkaline liquid. suitable for use on epoxy coatings and most common metals except
aluminium, tin, zinc, galvanised materials and zinc silicate coatings.

Specific gravity (20°C) : 1.34


Flash point : none
pH (1% solution) : 12.8

Contains approx. 30% Sodium Hydroxide.

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN RUST

Acidic liquid product for the cleaning of aluminium, copper and removal of rust stains on
paint work.

* Cleans and brightens aluminium and copper.


* Removes rust stains without risk to paintwork.
* Safe on most common metals.

Application

Careclean Rust is used for the cleaning of aluminium floor plates, copper and brass fittings, wooden
decks and the removal of lime after tank cleaning operations.

Directions for use

In most cases Careclean Rust is applied by brush diluted in solutions ranging from 10-50% and left
to react for 5-10 minutes. Smaller objects can be soaked in plastic container. After cleaning, rinse
items thoroughly with a water jet.

Paintwork
Dilute Careclean Rust 1 liter of product to 4-9 liters water, apply the solution by brush or spray
using plastic equipment and leave to soak for 10-20 minutes. Rinse off using a powerful water jet
with a brush, if necessary.

Tankcleaning
If lime scale stains are present after completion of tank cleaning operations, inject 0.5 liters
Careclean Rust per 100 liters washing water directly into the automatic washing system approx. 20
minutes. The recommended temperature is 75-85°C.
For detailed instructions on tankcleaning refer to the Marine Care Tank Cleaning Manual.
A range of support equipment is also available.
Properties

Colourless fluid contains phosphoric acid. Non-flammable and completely soluble in water. Within
the reaction time suitable for use on all metals and painted surfaces.

Specific gravity (20oC) : 1.21


Flash point CC : none
pH (1% solution) : 2.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN NEUTRAL HCF

Universal neutral liquid degreaser for the removal of vegetable oils and animal oils and fats
from zinc-silicate coated tanks.

• Neutral cleaning product based on highly efficient dissolving and low foaming nonionic
surface active agents.
• Expecially developed for the removal of vegetable, animal and mineral oils as well as fats
where cleaning with Careclean Alkaline Extra or Careclean Alkaline is not possible.
• Suitable for cleaning tanks coated with zinc-silicate and all common metals.

Application

1. Careclean Neutral HCF can be used for the removal of vegetable and/or animal oils and fats
and light mineral oils in aluminium and/or zinc-silicate coated tanks.
2. Careclean Neutral HCF can be used as an after treatment agent in hydrocarbon free cleaning
operations where cleaning has been carried out with e.g. Careclean Degreaser HD or Careclean
Degreaser GP.

Directions for use

Cleaning of tanks
Prewash before cleaning with Careclean Neutral HCF it is recommended to prewash with hot water
at 50°C. For drying and semi-drying oils a prewash with cold water should be carried out
immediately after discharge of cargo to retard oxidation and hardening of oil residues.

Recirculation method
A chemical solution is prepared in an empty slop tank or one of the after tanks near the pump room,
circulated via the automatic tank washing system pump and heater to the tank to be cleaned,
wherefrom the solution is returned to the chemical solution tank via the stripping line. Usually it is
not possible to recirculate the chemical solution through the tank washing system heater (to
maintian solution temperature) without making a temporary connection between the chemical
solution tank and the tank washing pump. Capacities of solution tank, pipeline and pumps etc.
should be calculated carefully to ensure sufficient volumetric quantity for a continuous
recirculation.
Depending on size and condition of tanks to be cleaned and quantity of chemical solution, a
drawback in this method is that usually only 3 (three) tanks can be cleaned with one solution after
which a fresh solution should be made and heated before cleaning can continue.
Depending on the degree of contamination Careclean Neutral HCF is circulated as a 2-3% solution
for a periood of 2-6 hours. The water temperature should be approx. 20-60 °C. After the circulation
period rinse thoroughly with water.

Spray method
Spray the hot tanksurfaces with undiluted Careclean Neutral HCF until the surfaces are well soaked
and let the product act for at least 30 min. Then rinse all tank surfaces with water at max. 60°C for
45 minutes.

Hydrocarbonfree cleaning
Hand spray Careclean Neutral HCF on the hot tanksurfaces and let it act for 30 minutes.
Rinse thoroughly with hot chloride free water when cleaning is completed. If fresh water is used,
steam tanks afterwards to remove any chlorides which may cause delay in passing the chloride test
for methanol etc.

For detailed instructions on tank cleaning refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.

Properties

Neutral colourless liquid with a characteristic odour. Completely miscible with sea water and fresh
water. Suitable for use on zinc-silicate coatings and most common metals. Limited application on
epoxy coatings (maximum concentration 10% and maximum temperature 60°C)

Specific gravity (20%) : 1.00


Flash point PM CC : 74 °C
pH (1% solution) : 7.00

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER GP

Emulsifying cleaning agent for the removal of medium to heavy mineral oils and fats by
spraying and brushing.

• Emulsifying cleaning agent based on aliphatic hydrocarbons, non-ionic and anionic


surface active agents.
• Most universally applicable product form the series of emulsifying cleaning agents.
• Suitable for the removal of most mineral oils and fats and preserving agents.
• Safe for use on common metals, epoxy and zinc-silicate coatings.

Application

Cooling systems
Along with the usual lime deposits, traces of mineral oils are often found in cooling systems.
These oil and fat deposits hinder optimum removal of the hardness deposits when using acid
cleaners (e.g.Careclean F Descalex P). In such cases, it is recommended to use an emulsifying
cleaner before the acid cleaning, to remove these deposits. Careclean Degreaser GP is ideal in
these cases.

Spraying
Careclean Degreaser GP can be sprayed undiluted onto the components to be cleaned.

Tanks
Careclean Degreaser GP can be used for the removal of most mineral oils and fats in loading and
storage tanks.

Directions for use:

Cleaning of cooling systems


Fill the cooling system with an emulsion of Careclean Degreaser GP and water. Depending on the
degree of contamination, 100 liters of cleaning liquid should contain 5 to 10 liters of Careclean
Degreaser GP.
Allow this emulsion to circulate for 12 - 24 hours at maximum temperature of 60°C. After this
operation, drain the cleaning liquid and rinse the system intensively with water until the outlet
water remains clear. Add cooling water treatment Caretreat 2 Diesel into the system.
Spray method
Spray the objects to be cleaned until they are thoroughly dampened with undiluted Careclean
Degreaser GP. Let the product act for 20-60 minutes, then rinse the objects thoroughly with water.

Note: Objects subject to corrosion should not be rinsed with water; use in this case, for example,
Careclean ECS Quick Dry.

Cleaning of tanks

Prewash
Before cleaning with Careclean Degreaser GP it is recommended to prewash with hot water at
approximately 60o C, except for drying and semi-drying oils where a prewash with cold water
should be applied.

Spray method
Spray the tank with undiluted Careclean Degreaser GP until the walls are thoroughly dampened
and then let the product soak in for at least 30 minutes. Rinse each tank compartment for 45
minutes with water at 60oC.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A
range of support equipment is also available.

Properties:

Undiluted at room temperature or in emulsions with water up to 6% at a maximum temperature of


60°C.
It can also be used on plastic materials, epoxy and zinc-silicate coatings. Light yellow neutral
liquid. Non-corrosive. Emulsifiable with water.

Specific gravity 20°C : 0.82


Flash Point PM CC : 65°C
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN DEGREASER HD

Emulsifying cleaning agent with a high flash point for the removal of crude oil, bitumen,
paraffin and similar substances by circulation method

• Emulsifying cleaning agent based on aromatic solvents, anionic and nonionic surface active
agents.
• Specific solvents with high boiling and flash points.
• Ideally suitable for the removal of crude oil, bitumen, paraffin and other high melting point
stains.
• Can be used undiluted up to 80°C.
• Safe for use on most common metals, epoxy, polyurethane and zinc silicate coatings.

Application

Heavily Contaminated Steam Boilers. Scale in steam boilers where heavy oil contamination is
present, will not easily be removed by acid cleaners. In such cases, Careclean Degreaser HD is used
first to remove oil and grease before the acid cleaner is applied.

Tanks
Careclean Degreaser HD can be used to clean heavy oil, crude oil, bitumen, paraffin and other stains
having a high melting point in which cases a high cleaning temperature is necessary.

Directions for use

Cleaning of steam boilers


Fill the system with a 5% solution of Careclean Degreaser HD in water. Allow this emulsion to
circulate for 12 - 24 hours at a maximum temperature of 90o C. After this operation, drain the
cleaning liquid and rinse the system intensively with water.

Cleaning of tanks

Prewash
Before cleaning with Careclean Degreaser HD, it is recommended to pre-wash with hot water at
approximately 50o C. For drying and semi-drying oils a pre-wash with cold water should be applied.
Recirculation method
Careclean Degreaser HD is added to a mixing tank containing a quantity of water which amounts to
1% of the capacity of the tank to be cleaned. The water is heated by means of the heating coils in the
tanks.

The tanks are washed by means of a loading pump, after which the solution used is recycled to the
mixing tank. One solution is most often used to wash 2 - 3 tanks.
Careclean Degreaser HD must be circulated as a 2-6% emulsion. Allow this emulsion to circulate
fodr 2 - 6 hours at a temperature ranging from 50 - 90o C.

For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.

Properties

Light yellow colored neutral liquid. Emulsifiable with water. Non-corrosive on common metal.

Specific gravity (20o C) : 0.99


Flash point PM CC : 87°C
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER
HEAVY DUTY SPLIT

A cleaning agent with excellent separating properties for the removal of mineral oils and
similar residual sediments.

* Suitable for removal of mineral oils.


* Strong emulsifying cleaning agent.
* Suitable for cleaning of engine rooms.
* safe on most common metals and polyurethane, epoxy and zinc silicate coatings.
* After 24 hours without circulation the emulsion splits into water and oil containing
Careclean Degreaser Heavy Duty Split.

Application

* Ideal tankcleaning product for removal of mineral oils and fats.


* May be used full strength in spraying application method.
* Excellent for removal of residues from engine room floor plates and decks.

Directions for use

A) Degreasing

1) General cleaning
Dependant upon the degree of contamination Careclean Degreaser Heavy Duty Split can be
used pure, or diluted with water as a 2 to 20% emulsion at temperatures of 20 - 50 °C. After
cleaning rinse with water.

Note: When making up an emulsion always add the product to the water in that order, whilst
stirring constantly.

2) Floorplate maintenance
Careclean Degreaser Heavy Duty Split should be used undiluted when cleaning decks and
floorplates. Spray the area to be cleaned with full strength product and allow to soak for
between 10 to 30 minutes. Brush the treated surface occasionally and finally rinse with
water.

Important note: Before commencing any cleaning all rubber type sealing rings etc. should
be tested for compability with the cleaning solution.
B) Tank Cleaning

1) Prewash
Before cleaning with Careclean Heavy Duty Split it is recommended to prewash with hot
water at approx. 50°C, except for drying and semi-drying oils where a prewash with cold
water should be used.

2) Recirculation method
In this method Careclean Degreaser Heavy Duty Split is added to a separate tank containing a
previously determined quantity of water. The quantity of water required for cleaning the tank
usually amounts to 1% of the capacity of the tank to be cleaned.
The solution is heated by means of heating coils in the tanks. The tanks are washed using a
cargo pump after which the used solution is recycled to the mixing tank. In the
recirculation method use is often made of the sloptank for the preparation of the cleaning
solution. One solution is normally used to wash 2-3 tanks after which a new batch must be
prepared. Careclean Heavy Duty Split must be circulated as a 2-6% emulsion.
Allow this emulsion to circulate for 1-3 hours at a temperature of between 20-50°C. After
the circulation period, rinse thoroughly with water.

3) Spray method
Spray the tank walls with undiluted Careclean Heavy Duty Split until they are thoroughly
dampened. Allow the product to soak for at least 30 minutes. Rinse each tank compartment
for 45 minutes with water at 60°C.

4) Spot Cleaning
For spot cleaning, use the manual Spraying method described above. However, Careclean
Heavy Duty Split is not suitable for hydrocarbon free cleaning operations. In such cases it is
recommended to use Neutral HCF. For detailed instructions on tank cleaning refer to the
Marine Care Tankcleaning Manual.

Properties

Light brownish neutral liquid based on aromatic hydrocarbons and surface-active


components. During recirculation miscible with water up to 50%, however, without
circulation it splits into water and product.

Specific Gravity (20%) : 0.9


Flash point : approx. 80 °C
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARECLEAN VOYAGE (SEACLEAN)

Strong emulsifying cleaning agent for the removal of heavy crude oil, soot, ashpalt and carbon
black stains, by direct injection, Voyage method, spraying and/or recirculation-METHOD.

* Strong emulsifying cleaning agent based on aliphatic/aromatic hydrocarbons and non


ionic/anionic surface active agent.
* Especially suitable for the direct injection and Careclean Voyage method, as product contains
a high percentage of surface active agent.
* Washing times are reduced by 50% and only slight agitation is normal required.
* The product is safe to use on common metals.

Application

Tanks
Careclean voyage can be used for the removal of most mineral oils and fats in cargo and storage
tanks.

Double Bottom Tanks


Careclean Voyage can be used for cleaning and gas freeing of double bottom tanks, using the rolling
motion of the ship which normally provides sufficient agitation.

Directions of use

Cleaning of cargo and storage tanks.

Prewash
Before cleaning with Careclean voyage, it is recommended to prewash tanks with hot water of
approximately 50° C except for crude oil drying and semi-drying oils where a prewash with cold
water should be applied.

Direct Injection Method For Cargo Tanks:


Undiluted Careclean Voyage should be injected at a predetermined rate into the pressure side of the
automatic tank cleaning system line on deck, by means of an airoperated drum pump. Usually an
injection rate of 0.1 - 0.2 litre Careclean Voyage per 100 litres of tank wash water is sufficient.
Cleaning time 2-6 hours. Subsequently rinse with water.
Hand Spraying Method
Spray undiluted Careclean Voyage directly on to bulkheads, frames, stringers etc. using an air-
operated drum pump connected with a delivery hose and hand spray gun. After a pre-determined
reaction time, tanks should be rinsed with water using the automatic tank washing machines. For spot
cleaning only use hand held hose for rinsing, for instance fire hose with nozzle. Hand spraying
method is the most economical system in terms of chemical consumption but requires tanks being
gasfree enabling men to enter tanks.
However, hand spraying method has a practical time limitation depending on tank sizes, i.e. total tank
surface to be sprayed.

Recirculation method
A chemical solution is prepared in one of the after tanks near the pump room. circulated via the
automatic tank washing system pump and heater to the tank to the cleaned, wherefrom the solution is
returned to the chemical solution tank via the stripping line. Usually it is not possible to recirculate
solution through the tank washing system heater (to maintain solution temperature) without making a
temporary connection between the chemical solution tank and the tank washing pump.
Capacities of solution tank, pipelines and pumps etc. should be calculated carefully to ensure
sufficent volumetric quantity for a continuous recirculation. Depending on size and condition of
tanks to be cleaned and quantity of chemical solution a drawback in this method is that usually only 3
(three) tanks can be cleaned with one solution after which a fresh solution should be made and heated
before cleaning can continue. The required solution strength is 2 - 6 % Careclean Voyage.
After chemical cleaning the tanks should be rinsed thoroughly with sea water of fresh water
depending on availability and requirements.

Voyage Cleaning Method: (Double Bottom Tanks)


Time, temperature and agitation of chemical solution are important factors for the successful cleaning
of Double Bottom.

Tank
1. Heat tank to higher than normal temperature, pump out as much fuel as possible and trim
vessel to ensure complete stripping.
2. Close all valves on engine room manifold.
3. Introduce first dose of Careclean voyage, through the sounding pipe, in accordance with the
dosage table stated below and fill the tank to 25% of its capacity with sea water. For filling
the tanks it is adviced not to use the ballast lines as they may contain fuel oil making the
cleaning more difficult.
4. Heat cleaning solution to minimum 60°C and maintain temperature for 48 hours. If heating
coils are not available, live steam may be used for heating the solution and maintain
temperature.
5. Empty tanks completely, fill to 50% capacity and empty again. Where single stage cleaning is
used the previous steps are ignored.
6. Add second dose of Careclean voyage and fill tank with sea water to 50% of its capacity,
continue heating and maintain at this level for 48 hours.
7. Add further sea water to fill tank to 75% capacity, continue heating and maintain for another
48 hours.
8. Empty tanks and pressure rinse with clean water through sounding pipes for 1-1 hour under
continuous stripping. Pressure should be kept as high as safety permits.
9. When rinsing is completed stop discharge (stripping) pump and fill tank until clear water runs
from sounding pipes on deck.
10. Stop water supply and empty (strip) tank. Trim vessel to ensure complete stripping.

Note: If tanks are not serverely contamined and/or the fuel oil viscosity is lower than 180 cSt at
50°C th cleaning process should be in one stage using step 5-10 only.

Properties

Highly concentrated blend of aromatic solvents emulsifiers and surface active ingredients. Light
yellow coloured neutral liquid. Emulsifiable with water to a maximum of 50%. Undiluted at room
temperature or in emulsions with water up to 6% at a maximum temperature of 60°C it can also be
used on plastic materials, epoxy and zinc silicate coatings.

Specific gravity (at 20o C) : 0,89


Flammable, flash point PM CC : 69° C
pH (1% Solution) : 7,0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
Dosage table of Careclean voyage

Tank capacity Proportioning of T.A.S. in liters Tank


in tons Minimum Normal Maximum

2-5 2 4 6
5 4 8 12
10 8 16 24
15 12 24 36
20 16 32 48
25 20 40 60
30 24 48 72
40 32 64 96
50 40 80 120
75 60 120 180
100 80 160 240
200 160 320 480
250 200 400 600
300 240 480 720
400 320 640 960
500 400 800 1200
600 480 960 1440
700 560 1120 1680
800 640 1280 1920
900 720 1440 2160
1000 800 1600 2400

For detailed instructions on tank cleaning, refer to the Marine Care Voyage. A range of support
equipment is also available.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN MULTICLEANER

A Completely biodegradable general purpose cleaner.

* Powerfull cleaner
* For general and tankcleaning
* No organic solvents
* Non flammable
* Suitable for most surfaces

Directions for use

General & Tankcleaning


Careclean Multiclean can be diluted to a 2-10% solution in water. It can be used for spraying,
recirculation and direct injection. The effectiveness of the product is increased by using water at a
temperature of 60 to 80°C for dilution and rinsing.

Properties

Careclean Multiclean is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.

Specific gravity (20°C) : 1.05


pH (1% solution) : approx. 9
Flash point : none

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN AQUAWASH

A Completely biodegradable general purpose cleaner.

* Bio degradable
* Mineral oil free
* No organic solvents
* Non flammable
* Suitable for most surfaces

Directions for use

Spraying
For contamination, Careclean Aquawash is sprayed on undiluted and left for 20 - 60 minutes. It
must then be hosed off with a powerful waterjet, whilst brushing the surfaces.

General cleaning
Careclean Aquawash can be diluted to a 2% solution in water for light cleaning. It must be
allowed to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product
is increased by using water at a temperature of 20 up to 60°C for dilution and rinsing.

Properties

Careclean Aquawash is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.

Specific gravity (20°C) : 1.05


pH (1% solution) :7
Flash point : none

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN GP ENVIRO

A water based general purpose degreaser for engine room and


deck cleaning

• Contains no petroleum solvents, non-flammable.


• Biodegradable, non-toxic, waste water will split into an oil/water phase.
• Clean, fresh odor.
• Retains strong degreasing properties when diluted.
• Leaves no film residues on cleaned surfaces.
• Economical in use.
• Suitable on most common metals and coatings.
• Suitable for use in conjunction with oil water separators.

Application

Careclean GP Enviro is used for engine rooms, decks, bulkheads and accommodation.

Directions for use

For heavy contamination


Careclean GP Enviro is applied by spray undiluted and left for 20-60 minutes. It must then be hosed
off with a powerful waterjet, whilst brushing the surfaces.

General Cleaning
Careclean GP Enviro can be diluted to a 2% solution in water for light cleaning. It must be allowed
to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product is increased
by using water at a temperature of 20 up to 60o C for dilution and rinsing.

Properties

Soluble in water. Pale yellow colored liquid with a fresh odor.

Specific gravity (20o C) : 0.995


Flash point (PM CC) : None to boiling (100° C)
pH (1% solution) : 9.1

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN COALTAR

Emulsifying cleaning agent for the removal of coaltar, crude benzene pyrolyse gas oil,
bitumen and similar substances

• Effective cleaner which will not leave carbon residues on the cleaned surface.
• Excellent for heavily contaminated heat exchangers.
• Economical cleaner which can be used as an emulsion with seawater.
• Minimizes waste waters, because of fast separating properties (product + contamination sink to
the bottom of separation tank because of its specific gravity.

Application

Careclean Coaltar is used for cleaning of tanks, heat exchangers, air coolers etc.

Directions for use

For Cleaning of Tanks


1.) After discharging, prewash (2 hrs.) the tanks with seawater at a maximum temperature of 50o C.
2.) Remove any sediment by hand.
3.) Make a solution in the tank which has to be cleaned in the ratio 100 liters of Careclean Coaltar
to 900 liters of water.
4.) Heat the solution up to approx. 50o C, by use of the heating coils.
5.) Start the circulation. (Cargo pump, cargo line with jump to the butterworth line to the
butterworth machine).
6.) Continue circulation for about 4-8 hours at the same temperature.
7.) Pump the solution into another tank.
8.) Wash the tank with water and inject Careclean Voyage or Careclean Degreaser GP into the
butterworth line if necessary.
9.) If the tanks are coated with zinc silicate, there may be a discoloration after the cleaning. If so,
make a solution of fresh water and Careclean Buffer 5.5 conc. in the tank in the ratio of 9 to 1 =
10% sol.
10.) Heat this solution up to 50o C.
11.) Start circulation following item 3.
12.) Continue with the circulation for 1-2 hours.
13.) Wash with fresh water.
14.) Drain the tank.
15.) For chloride free cleaning steam the tanks with live steam.

For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.
For cleaning of heat exchangers, etc.:

1.) Start with a shock treatment with steam followed by flushing with cold water to break hard
deposit layers, which will help the cleaning with Careclean Coaltar afterwards.
2.) Fill the system with Careclean Coaltar and circulate by means of a pump at max. 50o C for
approximately 8 hours.
3.) Drain and flush with water.

For cleaning of air coolers

For badly soiled air coolers use the circulation method or spray system.

Careclean Coaltar is used undiluted by means of a pump, spray and drain tank by circulation
through the air cooler. The cleaning temperature should be 50o C, cleaning time approximately 8
hours.

During the cleaning, the system should be closed and the area around must be ventilated well.

Cleaning in immersion baths

Careclean Coaltar is used undiluted in immersion baths for the cleaning of metal components,
which are badly soiled with Coaltar or similar substances. Afterwards, the parts must be well
flushed with water.

During the cleaning, the bath must be closed and the area must be ventilated well.

Properties

Careclean Coaltar is a slightly yellow coloured liquid with characteristic odour, consisting of a
mixture of 1.2 dichlorobenzene, hydrocarbons and non-ionic + cationic detergents.

Suitable for use on most common metals, however, should NOT be used on rubbers (except Viton
rubber) and plastics (except nylon, polypropylene, epoxy coating and polyurethane).

Flash point c.c. : 87°C


pH (1% solution) :7
Specific Gravity at 20o C : 1.25

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies
outside our control we cannot accept any liability for the results.
CARECLEAN BUFFER

Cleaning agent for zinc-silicate coated tanksurfaces

• Suitable for the removal of traces of lead and iron stains from zinc silicate coated tank
surfaces after transport of leaded gasoline.
• Suitable for the removal of traces of chloride and sulphide.
• Safe buffered pH of 5.5 for application on zinc-silicate coated tank surfaces.
• Gives a good cleaning result with a reduced cleaning time.

Application

The ordinary cleaning method with a synthetic soap takes a lot of time and is insufficient. A mild
complexing acid solution in combination with synthetic soap gives a much better cleaning result.
Careclean Buffer is used as a final cleaning procedure when leaded gasoline must be removed or
when the tank has to be completely chloride or sulphide free, e.g. for shipping pure chemicals.

Directions of use

After the normal cleaning depending on the nature of the last cargo and subsequent rinsing with
water, the cleaning with Careclean Buffer can start. Never dilute with river or seawater. Fill a
tank for 1/100 part with water and add 10% Careclean Buffer at maximum. The solution is
heated by means of heating coils in the tanks. The tanks are washed with a loading pump, after
which the used solution is recycled to the mixing tank. Usually, one solution is used to wash 2 -
3 tanks.
Careclean Buffer is circulated with a limited contact time of 30 - 45 minutes before rinsing at a
temperature not to exceed 45°C.
Of essential importance for passing the chloride test is a final rinse with chloride free, if possible
hot, water.
If necessary, repeat this cleaning procedure.
Properties

Mild acid, yellowish liquid with a characteristic odour. Completely miscible with water. For use
on all common metals, specially developed for cleaning zinc-silicate coatings.

Specific gravity (20°C) : 1.05


Flash Point : none
pH (conc.) : 5.3 - 5.5
pH (10% solution) : 5.5

For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.

The details of our product are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN AIR FRESH

Waterbased liquid to eliminate unpleasant smells.

Careclean Air Fresh is a liquid based on perfumed oils in water. It is suitable for eliminating
unpleasant smells in tanks.
Careclean Air Fresh is safe to use on most common metals and coatings.

Application

Careclean Air Fresh is often used if, after the cleaning of tanks a smell of the previous cargo (e.g. fish
oil or terpentine) is perceptible after tankcleaning. It is recommended that the cause of the smell is
determined before applying the product. If the smell is caused by bad cleaning, the tank should be re-
cleaned because application of the product without tankcleaning may cause a surveyor to reject.

Directions for use

Careclean Air Fresh is sprayed in a 1:10 dilution with water. Normally, 1 to 2 liters of product is
sufficient for one 400 m3 tank. Let the product evaporate for a reasonable period. It is also possible
to dose 0.1 - 1% of the product to the last rinsing water after tankcleaning. Before entering the tank
after treatment, it should be thoroughly ventilated.

Properties

Green colored liquid with a specific smell. Not corrosive to most common metals and coatings.
Non-flammable, miscible with water.

Specific gravity : 1.00


Flash point pm C.C. : None
pH (1% solution) : 7.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN PICKLING LIQUID

Liquid for pickling austenitic stainless steel

Careclean Pickling Liquid is based on nitric acid, hydrofluoric acid and non-ionic surface-active
substances.
The fluid may be used only on austenitic stainless steel as it corrodes other materials.
It removes weld slag, annealing scale, grinding dust and iron parts etc.

Applications

Careclean Pickling Liquid is used mainly for pickling installations and tanks. It may be used in
the following ways:
1. By circulation
2. Spraying
3. In immersion baths

Directions for use

Pretreatment
Before commencing clean and degrease the surfaces to be pickled, this will give the basis for
uniform pickling. Use Careclean ECS Quick Dry to remove felt pen ink marks.
Use Careclean Alkaline for degreasing small metal surfaces. To degrease tanks etc. We advice the
use of a 1-5% solution of Careclean Aquawash in warm water. After pickling rinse thoroughly
with a jet of water.

Circulation method
This method is used mainly for pipe systems. Fill the system with cold undiluted Careclean
Pickling Liquid. Pickling will take 2 to 6 hours depending on the degree of soiling and on the kind
of austenitic steel do not pickle longer than necessary. Drain the system and rinse carefully,
preferably with demineralised water. After rinsing if required passivation should follow
immediately.
For this use Careclean Passivating Liquid.

Note: Before disposing the pickling liquid it should be neutralised with slaked lime.
Immersion bath method
Fill a plastic or plastic lined bath with undiluted Pickling Liquid. Place the articles to be pickled
into the bath and leave them to soak for 1 to 6 hours depending on the degree of soiling and the
kind of austenitic steel.
Remove the articles from the bath and spray them with a powerful water jet. Demineralised water
should preferably be used for this purpose. Passivation should follow immediately after spraying.

Passivation

A protective oxide layer will form on the austenitic stainless steel only if oxidizing conditions are
present. For example during longterm rinsing in oxygen rich water of during storage in the open
air.
In these circumstances the steel automatically passivates. Because this passive layer takes a long
time to develop to the correct thickness we recommend passivating with Careclean Passivating
Liquid, particularly if the stainless steel is exposed to corrosive conditions soon after the pickling
treatment.
Good results are obtained if the object is sprayed/brushed with Careclean Passivating Liquid
immediately after it has been rinsed. Rinse with plenty of water after approx. 5 minutes.

Treatment of the effluent

To neutralise the acid and to make the fluorides and heavy metals insoluble the effluent water and
paste should treated with slaked lime to give a pH balance of 8,5-9. After the soluble substances
have settled the uncontaminated water may be drained. Isolate the insoluble contamination and if
possible drain by means of filtration, otherwise mix with sawdust and dispose of as chemical
waste.

Properties

Strong acidic product containing nitric acid and hydrofluoric acid. Fully miscible with water.
Suitable only for use on austenitic stainless steel. Corrosive on all other steels and many other
materials.

Specific gravity (at 20%) : 1,1


Flashpoint c.c. : none
pH (1% solution) : approx. 2

Extra Marine Care advice


When working in insufficiently ventilated conditions we advice you to wear a breathing filter for
acids.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN PASSIVATING LIQUID

Liquid for passivating austenitic stainless steel

• Passivating Liquid is based on nitric acid and non-ionic surface active substances.
• The product provides austenitic stainless steel with a protective oxide layer after it has
been pickled. The metal is then passive.
• Passivating Liquid, undiluted, is suitable for use only on austenitic stainless steel.

Application

Passivating Liquid is used mainly for the passivation of pickled installations and tanks.
It can be applied in the following ways:
1. by circulation
2. by spraying

Direction for use

General
A passivating treatment with Marine Care Passivating Liquid can only take place if the steel has
been pickled previously (i.e. treated with Careclean Pickling Liquid or Careclean Pickling Paste).

Circulation method
This method is applied mainly in pipe systems. Fill the system with undiluted cold Passivating
Liquid. The time taken for treatment is approx. 2 hours. Drain the system and rinse thoroughly
with demineralized water. After drying test the passivity of the steel using the Marine Care
Palladium Test Set.
N.B. Before disposing the passivating fluid it should be neutralised. For this use slaked lime.

Spraying
This method is generally used in tanks with a tank washing device which is resistant to our
product Careclean Passivating Liquid.
The Passivating Liquid fluid is sprayed undiluted using a spraytime of approx. 15 minutes. After
this rinse thoroughly with plenty of water using, preferably, demineralised. After drying, test the
passivity of the steel with the aid of a Marine Care Palladium Test Set.
Properties

Strong acidic product. Contains nitric acid. Fully miscible with water. Undiluted it is suitable for
use only on austenitic stainless steel. When diluted it is suitable for cleaning aluminium.

Specific gravity (at 20°C) : approx. 1.1 kg/ltr.


Flashpoint c.c. : none
pH (1% solution) : approx. 1.0

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN PICKLING PASTE
Pickling Paste for austenitic stainless steel.

INTRODUCTION

Careclean Pickling Paste is a colourless paste for austenitic stainless steel. It contains nitric acid and
hydrofluoric acid. It contains neither hydrochloric acid nor chlorides.

APPLICATION

Careclean Pickling Paste is used for the pickling of welded seams and surfaces of austenitic stainless
steel in any kind of construction, included for instance the outside of pipes and tanks. Steels other than
austenitic stainless steel will be corroded by the strong pickling effect of the Careclean Pickling Paste.
Nickel, nickel- and copper-nickel-alloys may also be pickled with the Careclean Pickling Paste.
Special precautions have to be followed to prevent these materials from corrosive attack.
Some of these metals and welding materials have been tested.
Kindly contact Marine Care for further information.

DIRECTIONS FOR USE

1. Pretreatment
See general information.

2. Pickling
Please read the security instructions before you start pickling.
During storage the paste may become partially liquid.
Mix the Careclean Pickling Paste, using a plastic or wooden spoon, then put it on the
surfaces and welded seams to be treated. Use a resistant brush without metal parts.
If the pickling treatment is protracted, clean the brush frequently, so that the dirt is not
widely spread. On conclusion, clean the brush thoroughly with water and allow it to dry.
The Careclean Pickling Paste is applied at room temperature, until the surface is well
covered; a thicker coating should be applied to the welded seams. 1 Kg. of the paste is
sufficient to treat about 70-150 m. of welded seams (5cm wide) or 4-8m² surface
depending on the quantity and nature of iron oxides to be dissolved.
Allow the pickling agent to act for 15-60 minutes on austenitic stainless steel, 5-20
minutes on nickel, nickel-alloys and copper-nickel-alloys (see Applications).
If the pickling has not been sufficient, then rinse and reapply the paste.
For a temperature change of 10 degrees centrigade up or down from
room temperature, the pickling activity and thus the pickling time changes roughly by a
factor of two. Normally it is sufficient to let the Careclean Pickling Paste act for the given
time without a further mechanical action. As the welding quality has a big influence, further
mechanical aid may become necessary. This may for instance be done by brushing with
brushes made from natural or plastic fibres or from austenitic stainless steel, provided
that the paste is still active.

3. Rinsing off the Careclean Pickling Paste


The Pickling Paste must be removed completely by an efficient rinsing process. The main
past of the paste may also be removed with rags or tissues.
Dirt that may not be chemically dissolved will be partially or completely loosened by the
acid creeping in between the metal and the contaminant. Therefore we recommend rinsing
with a cold high pressure water jet of at least 50-60 bar, to remove the dirt and the paste.
If higher pressure water jetting is not possible, then you can improve the rinsing by
brushing with e.g. natural or austenitic stainless steel brushes or with appropriate grinding
pads.
Nickel, its alloys and copper-nickel alloys have to be rinsed and cleaned very thoroughly
after pickling. The chloride content of the rinsing water should be as low as possible. If
possible, use demineralised water.

4. Passivation
See general information.

5. Treatment of the effluent


See general information.

PROPERTIES

Strongly acid product.


Product contains nitric acid and hydrofluoric acid, contains neither hydrochloric acid nor chlorides.
Completely miscible with water.
To be used for the pickling of austenitic stainless steel, too corrosive on other steels. To be used on
nickel, nickel alloys and copper-nickel-alloys under special precautions - please contact Marine Care.

Specific gravity (at 20°C) : 1,28


Flashpoint c.c. : none
pH (1% solution) : 1,1

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Special Products -
CARECLEAN SEWAGE

Sanitation system treatment and cleaner

* Assists in keeping drains, traps and lines clean and clog free.
* pH neutral and therefore not harmful to the system.
* Used to replace aggressive cleaners.
* Maintains system in optimum operational condition.

Application

Careclean Sewage can be applied by slug dosing or metering directly into the sewage tank
(i.e. Marine Sanitation Device (MSD), Collection, Holding and Transfer system (CHTS) or
other type of holding tank.)

A more convenient method is to apply directly to galley and Sewage facilities (e.g.
commodes, sink, shower, and scuppers) as a pH neutral cleaner to replace harsh acid, caustic
and bleach based products which are all highly harmful to the normal operation of any
biological system:

Careclean Sewage performs within a pH range of 5.5-8.5 and a temperature range 10-44oC.
Extremes of pH and temperature, as well as wide shifts in either parameter over a short
period of time should be avoided.

Directions for use

1. Start up dosage of 1 litre of Careclean Sewage per 1.000 litres of tank capacity should be
added directly to the holding tank and allowed a minimum of 24 hours after this initial
application for the system to become properly activated.
2. Additions should be made daily if used as a tankcleaner in amounts of 0,25 litre per 1.000
litres of additional liquids.
3. When used as a cleaner about 100 ml of product should be applied to each bowl, sink and
drain in the same manner as with any janitorial type cleaner. Note: When used as a cleaner,
Careclean Sewage will achieve the maximum results partly due to eliminating line blockage.
Physical properties

Appearance : white liquid culture


Odour : lightly perfumed
Completely soluble in water
* Environmentally safe, completely biodegradable.
* Minimum aerobic bacterial count 10 billion/litre
* Shelf life : 1 year
* Flash point : none
* pH Range : 5.5 - 5.8

Storage

* Store in cool, dry place


* Keep container closed when not in use.

For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.

The details of our products are given completely free of undertaking. Since their application
lies outside our control we cannot accept any liability for the results.
CARECLEAN ULTRASONIC

Cleaning liquid for use in ultrasonic cleaning baths and cleaning machines

* Suitable for use on all common metals (except zinc and some magnesium alloys)
* Designed for ultrasonic equipment
* Easy to dispose
* Low foaming so can be used in cleaning machines.

INTRODUCTION

The cleaning of heavily contaminated fuel and lubricating oil filters, cylinderheads and aircoolers
often give problems. The use of a cleaning agent only is generally unsatisfactory as only a part of
the deposits will be removed, and in most cases carbon residues and other solid materials will be
left behind. In such cases the use of ultrasonic sound waves in combination with a special cleaning
agent gives good results. The contamination will be removed by the ultrasonic process in the
liquid. The special detergents in the cleaning agent keep the contamination dispersed in the liquid
and the complexing agents will partly dissolve them. Careclean Ultrasonic has been developed for
use in ultrasonic baths for the cleaning of all materials except zinc, galvanised parts and/or
magnesium alloy.

APPLICATION

Careclean Ultrasonic is used in ultrasonic cleaning baths and in cleaning machines.

DIRECTIONS FOR USE

In Ultrasonic Cleaning Baths


The components to be cleaned can, if necessary, be degreased with Careclean Quick Split and
Careclean ECS Quick Dry. Depending on the degree of contamination, Careclean Ultrasonic
should be used in a 5 - 25% solution in water at a temperature of 50 - 70° C. Dismantle the
equipment to be cleaned (i.e. : remove top and bottom rings from filtercandles), put the
components in the bath taking care that the elements are completely immersed and kept separate.
We recommend a cleaning time of 5 - 30 minutes but longer if necessary. Take the elements out of
the bath and spray with a powerful waterjet. After drying, an Anti Moisture Spray can be used to
preserve the elements. The cleaning solution has to be renewed and the bath cleaned regularly,
because in a contaminated bath the parts cannot be cleaned effectively.

Marine Care design build and commission the "Caretech" ultrasonic cleaning bath systems.

Cleaning Machines
Careclean Ultrasonic is, depending on the nature and degree of contamination, applied in approx.
4% solution in cleaning machines. The contaminated objects must be placed in the machine and
cleaned for 30-60 min. at a temperature of 80 - 90° C. Finally rinse with water.

PROPERTIES

Careclean Ultrasonic is a low foaming mild alkaline liquid. It can be used on all common metals
except zinc, galvanised materials and some magnesium alloys. We advise to test lightmetal alloys
(aluminium/magnesium alloys etc.) i.e. pistons, turboblower parts etc. in advance
for 5-10 minutes. Suitable for use on synthetic materials, rubber and cured lacquers.

Colour : yellowish
Specific gravity (20°C) : 1.19
Flash point PM CC : none
pH (1% solution) : approx. 11,5

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN HAND

Cleaning gel for dirty hands

* Removes oil, grease and tar etc.


* Disinfects and moisturises skin.
* Not harmful to skin.
* Gel is stable up to 40° C.
* Pleasant smell.

Directions for use

Rub a little Careclean Hand into dry, dirty hands until the grease and dirt dissolves.
Rinse off with hot or cold water.

Properties

Red gel based on various detergents.

Specific gravity (20ºC) : 0.95


pH (1% solution) : 8

For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.

The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT BACTERIA

A microbiological control agent for use in water, lube oil and fuel oil systems

* Effective against bacteria and algae in oil and contaminated water.


* Special surface active component ensures complete coverage over large areas.
* Simple control and monitoring program.
* Easy to use liquid.

Application

Caretreat Bacteria is used in cooling water systems and oil storage facilities which have
problems due to bacteria colonization and/or algae in the oil/water interface.

Caretreat Bacteria is ideally suited to the sterilization of Marine Diesel Engine Cooling Water
Systems which have bacteria and/or algae infection.
Diesel Cooling Systems have been prone to this, due to the common occurrence of lubricating
and/or fuel oil mixing with cooling water. This gives an oil/water phase ideal for bacteria to
colonize rapidly. Water containing bacteria leaks into the lube oil system due to faulty glands,
joints and seals or during routine maintenance.
Small amounts of infested water/oil sludges in the storage and circulatory parts of the lube oil
system can quickly lead to major failure of bearing surfaces due to acidic conditions and
degradation of the oils lubricating properties.

Directions for use

Sterilization of the water system:


The system should be drained and refilled with fresh water treated with Caretreat Bacteria at
500-700 ml to each m3 of water.
Let the Caretreat Bacteria react for 48 hours under circulation with the separate cooling water
pump or with the unloaded engine.
During this operation, careful attention should be maid to blanked pipes and bypass loops, etc. to
ensure that they also receive adequate treatment.
After 48 hours, drain the system as quickly as possible through all outlets.
Refill the system with distilled water and add Caretreat 2 Diesel to give the correct corrosion
inhibition levels and add 500 ml Caretreat Bacteria to each m3.
The product is not to be used in potable water systems without special instructions from Marine
Care.
Directions for use

Sterilization of the water system:


The system should be drained and refilled with fresh water treated with Caretreat Bacteria at
500-700 ml to each m3 of water.
Let the Caretreat Bacteria react for 48 hours under circulation with the separate cooling water
pump or with the unloaded engine.
During this operation, careful attention should be maid to blanked pipes and bypass loops, etc.
to ensure that they also receive adequate treatment.
After 48 hours, drain the system as quickly as possible through all outlets.
Refill the system with distilled water and add Caretreat 2 Diesel to give the correct corrosion
inhibition levels and add 500 ml Caretreat Bacteria to each m3.
The product is not to be used in potable water systems without special instructions from
Marine Care

Sterilization of lube oil systems:


After serious contamination, all areas possible should be cleaned manually to remove sludge
and slime.
On large engines, cleaning with undiluted Careclean Heavy Duty Split of the casing frame
followed by opening and thoroughly cleaning the sumps is strongly recommended.
This should be followed by flushing of the entire lubricating oil system with a flushing oil
containing 500 - 700 ml of Caretreat Bacteria for every m3.

Sterilization of fuel storage tanks:


The action of bacteria in fuel during storage is widely misunderstood and its results often
thought to be that of stratification of blended fuels due to incompatibility.
If bacteria is suspected, water drawn from the fuel storage tank bottoms should be tested with
the Marine Care "Dip Slide Test" and the bacteria count established.

If it is above 105/ml, there is a good chance that colonization has taken place throughout the
fuel. In that case, treat at 700 - 1000 ml of Caretreat Bacteria to each m3 of fuel.

NOTE: These basic instructions are intended to give a reasonable guide to the actions required.

* Please contact Marine Care for more details and specific recommendations.

Properties

A light greenish liquid.

Specific gravity : 1.01


Flash point : None
pH (conc.) : approx. 3
IMO-Code : None.
NATURE OF SPECIAL RISKS AND SAFETY ADVICE

In accordance with the latest E.E.C. Council directives this product is not subject to any
official recommendation.

Voluntary Marine Care recommendation:


Harmful by inhalation and if swallowed.
In case of contact with skin/eyes, wash immediately with plenty of water.
Wear suitable gloves and eye/face protection.
CAREFLOC

A general purpose dispersant for effective removal of mud and silt from ballast tanks,
pipe line systems, open and closed cooling water circuits.

* Non hazardous, chemically inert product


* Prevents mud and silt from settling in tank
* Removes already settled mud and silt sediments
* Low dosage rates
* Biodegradability above 99%.

Directions for use

Cleaning dirty ballast tanks


Marine Care Carefloc must be dosed to the tank at the rate of 1 ltr. product to 10m3 water. If
possible water volume in the tank should be minimised to reduce product requirement.
Maximum agitation should be provided by back flushing when pumping out.

Ballast tank treatment


To maintain good conditions in a clean tank Carefloc must be added at 1 ltr. product to 20 m3
water.

Both dosage recommendations should be considered as the minimum for full effectivenes.

Carefloc should be added via the tank covers, avoiding dispersion problems when dosed via
vents or sounding tubes. If the latter is unavoidable, ensure that plenty of water is added
directly after, to aid mixing.

Open cooling water systems


Dirty systems should be cleaned by injecting Carefloc at the rate of 1 ltr. product to 10
m3circulating water flow over a one hour period every 24 hours. This rate can be reduced by
50% once a system is reasonably clean and requires maintenance of those conditions.

Diesel engine cooling water systems


Desludging must be carried out by injecting a minimum dose of 1 ltr. Carefloc to 10m3 water
capacity. Small systems of less than 2.5 m3 should use 0.3 ltr. of Carefloc regardless of
capacity. Carefloc should be injected into the system at a high dosing point, but if the header
tank is used, ensure that the make-up valve is closed and water level lowered below the
cylinder levels before Carefloc is added to the tank. Add the calculated volume of Carefloc to
the empty tank and then open the make-up valve to refill the system. This ensures that the
product enters the cooling circuit.
Circulate for 30 – 40 minutes then completely drain the system as quickly as possible using
all drains and removing covers if practical. Addition of untreated water whilst draining will
assist in removing treated sludge. Repeat the operation if sludge level is excessive.

Heat exchangers – sea water side


Static method
Isolate unit and add 1 ltr. Carefloc to 10 m3 water capacity. If possible, agitate with an air
line or temporary circulation loop. After 30 minutes, flush thoroughly with water to remove
all floculated deposits.

Note: If “on load” cleaning of specific coolers is required, inject 1 ltr. Carefloc to 10 m3
cooler throughput upstream of the unit for 1 hour.

General hints
A. Prolonged contact of Carefloc with sludge reduces its effective floculation. This should
be considered in ballast tanks which are not continuously being discharged. Sludge
should be removed within seven days maximum.
B. Above 60° C the effect of Carefloc is reduced and, if necessary, dosage rates must be
increased.
C. Carefloc will function over the full pH range, however, it is more effective in alkaline
conditions.
D. Do not use less than 1 ltr. of Carefloc to 20 m3 water.

Injection Equipment
Marine Care has a range of pump and tank units suitable for the injection of Carefloc.

Properties

Carefloc is a light yellow liquid.

Specific gravity (20°C) : 1.3


pH : approx. 7
Flash point : none
IMO-Class : non hazardous.

Nature of special risks and safety advice.


In accordance with the latest E.E.C. Council directives this product is not subject to any
official recommendation.

For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARECLEAN HIGH PRESSURE

Alkaline cleaning agent for use in high pressure machines

• Liquid alkaline cleaning agent.


• Suitable for removal of a large range of oil and greaser.
• Non flammable.

Application

Careclean High Pressure is mainly used for general cleaning of engine spaces, cleaning of
outside paintwork, cargo holds and tanks.

Directions for use

For use in high pressure machines generally use a 10% solution of Careclean High Pressure
mixed with water in a dosing tank (with pre-washing a 5% solution is sufficient). Adjust the
dosage to such that at the spray nozzle of the high pressure machine a 0.1 – 0.5% solution is
reached. Recommended cleaning temperature is 20 to 80°C. With persistent dirt it is
recommended to spray the product pure or diluted with water to a 10% solution on the object
to be cleaned. After a soaking time of 5 – 10 minutes spray clean water under high pressure.

Properties

Alkaline fluid. Good in hard water. Suitable for use on synthetic material, rubber, hardened
enamel and most metals. It is less suitable for use on aluminum, tin, zinc, galvanized material
and on zinc silicate coatings. Colourless and non-flammable.

Specific Gravity (20°C) : 1,08


Flash point : none
PH (1% solution) : 11,7

For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
PRODUCT DATA SHEETS

- Test Kit´s -
TEST SET - P-ALKALINITY - Product Code 11901

CARETREAT 3 BOILER

1. Completely fill the plastic measuring tube with boilerwater.


Pour the contents of the tube into the mixing bottle.

2. Fill mixing bottle with distilled water up to 15 ml.

3. Add the contents of one Phenolphthalein indicator Powder Pillow and swirl to mix.

4. A pink colour will appear. (If the water remains colourless the P-Alkalinity is zero)

5. Add the Sulfuric Acid Standard Solution drop by drop to the contents of the mixing
bottle, swirling the mixing bottle constantly. Count the drop until the test solution
becomes colourless. (One pipette filled to the 1.0 ml mark equals 15 drops.)

The recommended P-Alkalinity for boilers with a working pressure up to a maximum of


20 bars is 100-200 ppm as CaCC.
Initial dosage: 0,40 ltr. Caretreat 3 Boiler per metric ton boiler water.

Dosing Table

Number of p-Alkalinity p-value req.p/1000ltr


drops ppm CaCO3 mval/litr boilerwater

0 0 0 0.8
3 50 1 0.6
6 100 2 0.4
9 150 3 0.2
12 200 4 0.0

Notes:

- Instead of ppm CaCO3 the P-Alkalinity is sometimes expressed in mval/litre.


Calculation: drops X 1/3 = mval/litre (=p-value)
- Generally the p-value can be calculated if the ppm CaCO3 is known using the
following equation:
ppm CaCO3 : 50 = mval/litre
Warning:
Do not use the solution used for p-Alkalinity determination for Chloride level determination,
because Phenolphthalein indicator Powder Pillows contain Sodium chloride.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
TEST SET – CHLORIDE - PRODUCT CODE 11902

CARETREAT 2 DIESEL & CARETREAT 3 BOILER

(Do not use the solution used for p-Alkalinity determination)


Chloride level determination.

1. Fill the plastic measuring tube with the water to be tested. Pour the contents of the tube
into the mixing bottle.

2. Fill the mixing bottle with distilled water up to 15 ml.

3. Add the contents of one Chloride 2 Indicator Powder Pillow swirl to mix.

4. Add the Silver Nitrate Solution drop by drop to the contents of the mixing bottle,
swirling the mixing bottle constantly.
Count the drops until the test solution changes from yellow to red-brown in colour.
(One pipette filled to the 1.0 ml equals 15 drops).

Calculation: drops X 30 = Chloride-level (as ppm Cl)

Recommendations for maximum Chloride-level (ppm Cl) at various


boiler pressures.

0-15 bar 15-30 bar 30-40 bar 40-60 bar 60-80 bar
200 150 100 50 30

Adjust the Chloride-level by means of blow down and addition of distilled water. The
tons/24h blow down can be calculated using the following equation: Blow down
(ton/24h)=pcm Cl in make up feed X water added (ton/24h)

max. ppm Cl (see recommendations)

Notes:

- Instead of ppm Cl, the Chloride-level is sometimes express ppm NaCl (sodium chloride)
- maximum chloride level for cooling water is 100 ppm Cl. Adjust or condensate (free
of Hydrazine, rust) water.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
TEST SET - NITRITE - PRODUCT CODE 11903

CARETREAT 2 DIESEL

1. Thoroughly rinse the marked plastic dropper with the sample to be tested. Then fill
the dropper to the 0.5 ml mark with the sample and discharge it into the colour
viewing tube.
2. Fill this tube to the upper mark (= 10 ml) with demineralized (or battery) water.
Stopper and invert to mix.
3. Divide the diluted sample equally between the colour viewing tubes (each should be
filled to the 5 ml mark).
Add the contents of one Nitriver 2 Nitrite Reagent Powder Pillow to one of the
tubes. Stopper and shake to mix. If Nitrite is present a greenish-brown colour will
develop.(*)
Allow 10 minutes for full colour development.
4. Place the Nitrite Colour Disc in the Colour Comparator.
5. Place the tube prepared with Nitriver 2 in the right opening of the Colour
Comparator.
6. Place the other tube of diluted sample in the left opening of the comparator.
7. Hold the comparator up to a constant light source and view through the opening of
the comparator. Rotate the disc until a colour match is obtained. Read the scale.

Recommendations for cooling water treated with Caretreat 2 Diesel.

Nitrite normal rated engine 1200-2000 ppm NO2


high rated engine* 2500-3000 ppm NO2
Chloride normal rated engine max. 100 ppm Cl.
high rated engine* max. 50 ppm Cl.
Hardness max. 180 ppm CaCO3
pH 9,0 - 10,0

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
Caretreat 2 Diesel
Normal rated engine High rated engine

Scale Nitrite 0 – 50 50 – 100 Nitrite 0-50


Reading ppm NO2 ppm CL ppm CL ppm NO2 ppm CL

0 0 6.0 ltr. 8.0 ltr. 0 12.0 ltr.


10 200 5.3 ltr. 7.2 ltr. 400 10.4 ltr
20 400 4.5 ltr. 6.4 ltr. 800 8.8 ltr
30 600 3.8 ltr. 5.6 ltr. 1200 7.2 ltr
40 800 3.0 ltr. 4.8 ltr 1600 5.6 ltr
50 1000 2.3 ltr. 4.0 ltr. 2000 4.0 ltr
60 1200 1.5 ltr. 3.2 ltr. 2400 2.4 ltr
70 1400 0.8 ltr. 2.4 ltr. 2800 0.8 ltr
75 1500 0.4 ltr. 2.0 ltr. 3000 0.0 ltr
80 1600 0.0 ltr. 1.6 ltr. 3200
90 1800 0.8 ltr. 3600
100 2000 0.0 ltr. 4000

* Dosing table, dosage required per 1,000 litres cooling water.

Notes:

- We advice the use of distilled, demineralized or condensate (free of hydrazine, rust !)


water for suppletion and filling the system.

- High rated engine, means p. ³20 bar:


After adding Nitriver 2 Nitrite Reagent Powder Pillow fill both tubes to the upper mark
(=10 ml) with demineralized (or battery) water. Stopper again and invert to mix.

The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
COOLING WATER TREATMENT TEST (CARETREAT 2 DIESEL)

TEST TEST METHOD DOSAGE (LTR/ TON)

NITRITE 1. Completely rinse the dropper to be used, then fill the dropper to the 0.5ml mark * INITIAL DOSAGE: 6 LTR/TON (NORMAL RATED)
with the sample and discharge into color viewing tube.
* LIMIT: 2. Fill the tube to the upper mark (=10ml) with demineralized water. 1. Normal rated engine
3. Divide the diluted sample equally between the color viewing tubes (each) 5ml.
1. NORMAL RATE Add 1Nitriver 2 reagent powder pillow to one of the tubes, and stopper & mix PPM DOSAGE
1200-2000ppm well. If nitrite is present a greenisch/brown color will develop. Allow 10 min. 200 5.3 ltr
2. HIGH RATE for HIGH 4. Place the tube prepared with Nitriver 2 in the right position of comparator, and 400 4.5 ltr
SPEED ENGINE: the other tube place to the left. 600 3.8 ltr
2500-3000ppm Rotating disc of comparator until a color match is obtained. 800 3.0 ltr
1000 2.3 ltr
** SCALE READING x 20 = PPM AMOUNT 1200 1.5 ltr

** PH: 9-10

CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. UP TO 100PPM: SATISFACTORY
Pour the contents of the tube into the mixing bottle.
(Limit: up to 100ppm) 2. Fill the bottle with distilled water up to 15ml Over 100PPM: Partly drain and dose Caretreat 2 Diesel
3. Add 1 Chloride 2 indicator powder pillow and mix well. accordingly.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color

Amount of drops x 30 = Chloride PPM

*** TEST KIT 1. TEST SET FOR NITRITE 2. CHLORIDE TEST KIT 3. PH PAPER ***
DIESEL ENGINE COOLING WATER GRAPHIC LOG

M.F. Make and type: Cooling capacity: m3 Aux Engines: m3 Capacity: m3

Chlorides ppm Cl 30 60 90 120 Nitrite (Plot as X) pH Caretreat 2 Make


OK Medium High Excess 1200 1600 2000 2400 2800 ppm NO2 Diesel - added up feed
8.0 8.5 9.0 9.5 10 (Ltr.) added (ltr.)

Date: M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

M. ENGINE

HT SYS.

LT SYS.

AUX. ENGINE 1
AUX. ENGINE 2

Nitrate Level Main Engine: ** To increase Care 2 level by 100 ppm NO2 add 0,4 Ltr/ M3 Submitted by:
Between 1200 - 2000 PPM NO2
Nitrate Level Aux. Engine: Remarks: Approved by
Between 2500 - 3000 PPM NO2 Ch. Engineer
BOILER WATER TREATMENT TEST (CARETREAT 3 BOILER & CARETREAT 4 CONDENSATE)

TEST TEST METHOD DOSAGE

P-ALKALINITY 1. Completely fill the plastic measuring tube with boiler water. ** CARETREAT 3 BOILER **
Pour the contents of the tube into the mixing bottle.
* (Limit: 100-200ppm) 2. Fill the bottle with distilled water up to 15ml * Initial dosage: 0.75 ltr/ ton
3. Add 1 phenolphtalein indicator powder pillow to the mixing bottle and mix
4. A pink color will appear (if colorless, P-Alkalinity is zero). * Over 200ppm p-Alkalinity - decrease dosage by 25%
Add drop by drop sulphuric acid standard solution counting the number of drops, * p-Alkalinity level between 100-200ppm - satisfactory.
untill the solutions is colorless. * Below 100ppm p-Alkalinity - increase dosage by 25%

Drop: 0 3 6 9 12 ** pH: 10-11,5


PPM: 0 50 100 150 200

CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. *Up to 200ppm: satisfactory
Pour the contents of the tube into the mixing bottle.
* (Limit: up to 300ppm) 2. Fill the bottle with distilled water up to 15ml * Over 200ppm: blowdown
3. Add 1 Chloride 2 indicator powder pillow and mix well.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color

Amount of drops x 30 = Chloride PPM

CONDENSATE PH 1. Take condensate water sample, and immerse pH paper. ** CARETREAT 4 CONDENSATE **
2. Read the pH value..
* (Limit: pH 9-9.5) * Initial dosage: 0.2 ltr/ ton
* 0.4 ltr/ 24 hours - normal daily dosage

*** TEST KIT 1. TEST SET FOR P-ALKALINITY 2. CHLORIDE TEST KIT 3. PH PAPER ***
BOILER WATER GRAPHIC LOG

Date:

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

P. ALKALINITY / ppm CaCo3

350
300
250 Decrease Dosage 10%
200
150 Ideal
100
50 Increase Dosage 25%
0

CHLORIDES / ppm C1

210
180
150
120
90
60
30
0

CARETREAT 3 BOILER - DOSAGE (LTRS.)


2.0
1.5 Month
1.0 Total
0.5
0 ltrs
Maintain min. Dosage 0.2 LTR. / 24 HRS

CONDENSATE / pH
10.0 Decrease Care 4 Dosage 10%
9.5 Ideal
9.0
8.5 Increase Care 4 Dosage 25%

CARETREAT 4 CONDENSATE - DOSAGE (LTRS.)


2.0
1.5 Month
1.0 Total
0.5
0 ltrs
Maintain Minimum Dosage 0,4 Ltr. / 24 Hrs.

Vessel name: Remarks:


Month:
Year:
Boiler Type:
Pressure: bar Submitted by: