- MARINE CARE -
Maintenance
Coatings/Corrosion
Watertreatment
Fueltreatment
Tankcleaning
Special Products
Careclean Sewage Gamazyme BTC Microtreat L Biotal MDS 2000 Microfresh Liquid
Careclean Hand Natural Handcleaner Handcleaner / Green Gelatin
Careclean Ultrasonic Unitor USC Ultrasonic Multicleaner / Ultrasonic Multicleaner
Marine Care Chemicals – Ports of Delivery
- Maintenance Chemicals -
CARECLEAN GP ENVIRO
Application
Careclean GP Enviro is used for engine rooms, decks, bulkheads and accommodation.
General Cleaning
Careclean GP Enviro can be diluted to a 2% solution in water for light cleaning. It must be allowed
to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product is increased
by using water at a temperature of 20 up to 60o C for dilution and rinsing.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER GP
Emulsifying cleaning agent for the removal of medium to heavy mineral oils and fats by
spraying and brushing.
Application
Cooling systems
Along with the usual lime deposits, traces of mineral oils are often found in cooling systems.
These oil and fat deposits hinder optimum removal of the hardness deposits when using acid
cleaners (e.g.Careclean F Descalex P). In such cases, it is recommended to use an emulsifying
cleaner before the acid cleaning, to remove these deposits. Careclean Degreaser GP is ideal in
these cases.
Spraying
Careclean Degreaser GP can be sprayed undiluted onto the components to be cleaned.
Tanks
Careclean Degreaser GP can be used for the removal of most mineral oils and fats in loading and
storage tanks.
Note: Objects subject to corrosion should not be rinsed with water; use in this case, for example,
Careclean ECS Quick Dry.
Cleaning of tanks
Prewash
Before cleaning with Careclean Degreaser GP it is recommended to prewash with hot water at
approximately 60o C, except for drying and semi-drying oils where a prewash with cold water
should be applied.
Spray method
Spray the tank with undiluted Careclean Degreaser GP until the walls are thoroughly dampened
and then let the product soak in for at least 30 minutes. Rinse each tank compartment for 45
minutes with water at 60oC.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A
range of support equipment is also available.
Properties:
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN QUICKSPLIT
A solvent based quick separating oil and grease remover suitable for use in conjunction
with oily water separators and where IMO rules are required.
* Based on aliphatic hydrocarbon solvents, selected non-ionic and anionic surfactants which are
biodegradable.
* Good cleaning properties and fresh odour.
* Its emulsion with water and oil breaks up within a very short period. Less than 15 ppm oil
remains in the water and therefore the product meets the requirements of IMO.
* Suitable for the removal of most mineral oils, fats, greases and preserving agents.
* Safe to use on all common metals, painted surfaces, epoxy and zinc-sillicated
coatings.
* Has the approval of major manufacturers for use in oil-water separators.
* It fulfils TS 6850-017, edition 4 of the German military force.
* High flashpoint.
Application:
General maintenance
Careclean Quicksplit is used to clean machinery, floor plates and bulkheads in engine rooms.
Tanks
Careclean Quicksplit can be sprayed undiluted as a spotcleaner in tankcleaning (Marpol
requirements).
General maintenance
For cleaning in engine rooms etc., Careclean Quicksplit is used undiluted. Dampen the surface
to be cleaned and let the product act for 5 - 60 minutes. Brush the surfaces occasionally and
finally rinse them thoroughly with water at 50 - 60o C. For heavier contamination we
recommend Careclean HD Split.
Tanks
To be used as a spotcleaner to decrease the amount of slops. Spray the surfaces to be cleaned until they
are thoroughly dampened with undiluted Careclean Quicksplit. Let the product act for 5-60 minutes,
then rinse thoroughly with water at 50 - 60o C.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range of
support equipment is also available.
Immersion baths
Careclean Quicksplit is applied undiluted at ambient temperature or up to a maximum of 55o C in a
heated tank. Soak components for several hours, remove from the bath and rinse thoroughly with a
waterjet.
Practical hint
Where an oil-water separator is installed, collect the treated bilge water in the dirty water collecting
tank. After a reasonable separating time suck the bilge water from the bottom of the tank and discharge
overboard through the oil-water separator. This is the best way to keep within the IMO rule limits
(max. 15 ppm oil in the discharge overboard).
Note: The use of emulsifying products (old style degreasers) will affect the separating properties of
Careclean Quicksplit.
Properties
Clear yellow brown colored liquid. Mixture of aliphatic hydrocarbons and biodegradable surface
active agents. Non-emulsifiable in water.
The product is safe for use on all common metals.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN OSD ENVIRO
Application
Careclean OSD Enviro oil spill dispersant should be sprayed onto the oil slick using spraying
equipment connected to booms with spray nozzles supplied by a pump from storage tanks.
When using the product the sea surfaces should be agitated using breaker boards, boat
propellers, bow wave ect. to help disperse the oil. When dealing with small spills from vessels,
use hand spray pump or an eductor and fire hoses or monitor. This will mix the dispersant with
seawater, and agitating the sea will help break up the oil slick as well as applying the
dispersant. This technique has also proved valuable when dealing with small spills in ports and
harbors between ships side, wharfs and pilings, ect. or any area which has difficult access.
Technical Information
The effectiveness of the oil dispersant will vary depending on the state of the oil, i.e., its pour
point and viscosity at sea temperature and the time of weathering, evaporating of the lighter
fractions of oil and the formation of oil-in-water emulsions which will all quickly increase
viscosity and pour point and hence increase resistance to dispersion.
To be effective, it is essential to use Careclean OSD Enviro as early as possible in the cleanup
operation. We recommended users of oil dispersants to read the IMO publication ‘IMO/UNEP’
Guidelines on Oil Spill Dispersants Application and Environmental Considerations’. This book
gives more information on the application of dispersants. We would also like to point out that
the use of dispersants in many countries is governed by local authorities or Coast Guard and
permission to use the product must be sought.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN ECS QUICK DRY
A non-conductive degreasing electro cleaner which evaporate fully and is non corrosive.
Application
Spraying
Use Careclean ECS Quick Dry for switchboards, motors etc. If used in an enclosed space, keep well
ventilated. Use spray equipment which gives a fine spray but no fogging for best results. Once the
product has acted, use again to flush off contamination and afterwards blow dry with air.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ECS SAFE
• Special degreasing agent for the removal of oil and grease from machines and motor parts,
transmissions, ball bearings, gear wheels, metal parts, electrical components, etc.
• Odorless.
• Contains no chlorinated hydrocarbons or other harmful chemicals.
• Does not emulsify in water - the polluted oil can be separated by means of an oil/water
separator.
• High flash point.
Application
Careclean ECS Safe can be applied with a brush or by spraying the parts to be cleaned. This product
can also be used by filling an immersion bath to clean extremely dirty parts. The high flash point and
the fact that it is practically odorless makes Careclean ECS Safe a pleasant and problem free product.
Immersion Baths
Careclean ECS Safe is used undiluted and unheated in immersion baths. Put the parts to be cleaned in
the bath and soak for several hours. Thereafter, take the parts out of the bath and spray off with a
forceful waterjet.
Attention: parts that need to be rust free and dry (such as electrical components) should not be sprayed
clean with water but with clean Careclean ECS Safe and afterwards should be blow-dried completely
because of fire risk if residues are left behind.
General Cleaning
For the cleaning of dirty parts and surfaces use Careclean ECS Safe undiluted. Moisten the parts to be
cleaned thoroughly with the product. Depending on the measure of dirt, soak the product for 5 to 60
minutes, brush in between. After this, rinse thoroughly with water.
Attention: parts that need to be rust free and dry (such as electrical components) should not be sprayed
clean with water, but with Careclean ECS Safe and afterwards should be blow dried completely to
avoid fire risk.
Attention
Cold cleaners should only be used in combination with oil/water separators.
To guarantee an optimal oil/water separation, cold cleaners should never be used with greater amounts
of emulsifying cleaners (e.g. of High Pressure Cleaners) if the waste is passing oil/water separators.
Properties
Clear, odourless, fluid neutral degreasing agent based on among other things, high boiling aliphatic
hydrocarbon. Careclean ECS Safe evaporates without residue. Careclean ECS Safe can be used on
most metals, synthetic material, rubber and hardened metals, electrical components.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ACC
For manual and "in service" cleaning of Diesel Engine charge air coolers.
Application
Immersion bath
Dependant on design, the cooler is flooded with Careclean ACC or immersed in a tank full of
product. The product should be heated to approx. 50°C and agitation provided with an air line.
After 2 hours, drain off and flush well with water, followed by drying with an air line.
Circulation method
Some designs of cooler can be circulated "in situ". In this case a pump tank and pipe system is
fitted permanently or connections are provided for connecting a temporary circuit. The system
should be filled with Careclean ACC and circulation carried out for 2 - 4 hours at a temperature of
upto 50°C.
After cleaning the cooler should be thoroughly flushed with fresh water and dried with an air line.
Note: Both cleaning methods benefit from heat of up to 50°C and cleaning times can be reduced
or extended dependant on temperature and degree of fouling.
Direct injection
Careclean ACC has the approval of the majority of major manufacturers for use either in their own
design of "in service" cleaning system or other recognised systems provided by suppliers.
Injection systems
Marine Care offer a range of newly developed easy to operate manual systems.
Regardless of the type of "in service" system used, Careclean ACC should be dosed at the ratio of 2
parts water added to 1 part product (in that order) and well mixed for immediate use.
If the emulsion is left standing for up to 5 minutes its composition will change and effectiveness
reduced. It is most important that 5 - 10 minutes after dosing the solution, injection with fresh
water only is repeated using double the total volume of the first solution to flush off the chemical
residual which contains the "solved" contamination. Failure to do this will result in a "sticky
cooler" which will foul very quickly.
Turbo blowers
The water washing of the air side of turbo blowers has been accepted for many years. Most
manufacturers provide nozzles and dosing pots to inject water into the volute casing after the inlet
filters. These systems can be utilised with a solution of Careclean ACC at the same ratio of 2 parts
water mixed into 1 part product and dosed via the water wash system.
Note: When cleaning turbo blowers "in service" follow the equipment manufacturers instructions
regarding engine load and/or blower revolutions during the procedure.
As with normal water washing, do not attempt to clean a badly fouled blower as resultant removal
of deposits could cause imbalance of the rotor.
The principle to follow is prevention not cure.
Injection systems
Marine Care can give advise on modifications to existing equipment or retrofit packages. For
further details refer to the equipment information sheet.
Properties
Light yellow coloured neutral fluids, which emulsify with water and are safe in contact with all
metals.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN CARBON
Liquid cleaning agent for use in immersion baths for removing partially
carbonized oils
Application:
Careclean Carbon is applied undiluted for cleaning of highly soiled components. (e.g. cylinder heads,
gear boxes, pistons, oil pumps, injectors, pipes, burners, tubes, coolers, oil filters.)
Also old paint and lacquers can be removed with Careclean Carbon.
Immersion baths
Put the components in a steel bath filled with undiluted Careclean Carbon and let them soak for 2 to
10 hours, depending on the degree of contamination. Then take out the components and flush clean
with a powerful water-jet.
Properties
Careclean Carbon is a duel component liquid with a strong aromatic smell. It has no flash point, but
when used in immersion baths the flash point may fall in time to 80°C. Plastics and rubber should
first be tested for chemical attack.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN FILTER
Liquid cleaning agent for removal of partially carbonized oils using circulation method
• Based on a mixture of aliphatic and chlorinated aromatic hydrocarbons, cresols and anionic
surface-active agents.
• Removes partially carbonized oils.
• Timely cleaning prevents the formation of coke-like adherents.
• Non-corrosive.
Application
Careclean Filter is mainly used for the cleaning of permanently fixed oil coolers, oil pre-heaters and
metal/ceramic oil filters. These units are regularly contaminated by particles in the oil and partially
carbonized oils. Timely cleaning prevents the formation of coke-like adherents which are difficult or
impossible to remove.
Careclean Filter is used undiluted at cleaning temperatures not exceeding 60o C. The cleaning effect
is obtained by filling and/or circulating the product. Cleaning will take 8 to 24 hours depending
upon the degree of contamination.
Properties
Careclean Filter is a light brown colored fluid. Its formula includes cresols and chlorinated aromatic
hydrocarbons. Plastics and rubber should first be tested for chemical attack. The product may also
attack paints and lacquers.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN AQUAWASH
* Bio degradable
* Mineral oil free
* No organic solvents
* Non flammable
* Suitable for most surfaces
Spraying
For contamination, Careclean Aquawash is sprayed on undiluted and left for 20 - 60 minutes. It
must then be hosed off with a powerful waterjet, whilst brushing the surfaces.
General cleaning
Careclean Aquawash can be diluted to a 2% solution in water for light cleaning. It must be
allowed to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product
is increased by using water at a temperature of 20 up to 60°C for dilution and rinsing.
Properties
Careclean Aquawash is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN MULTICLEANER
* Powerfull cleaner
* For general and tankcleaning
* No organic solvents
* Non flammable
* Suitable for most surfaces
Properties
Careclean Multiclean is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
PRODUCT DATA SHEETS
Inhibited acid cleaning powders for removal of water scale and rust deposits from water
systems.
Application:
Careclean F Descalex P is an inhibited sulphamic acid based products suitable for the cleaning of
boilers, condensers, evaporators, butterworth heaters and pipe systems etc.
General
1. We recommend that a preliminary test is carried out on samples of the original scale or
deposit in order to select the most suitable acid cleaner and optimize concentration and
temperature conditions.
2. When a boiler is soiled with light oil deposits, or if silicates and/or calcium sulphates are
present, boiling out with Careclean Alkaline Extra is recommended.
3. If heavy mineral oil deposits are present in a boiler, a preliminary treatment with an
emulsifying cleaner, like Careclean HD Split or Careclean HD is recommended.
4. If heavy oil deposits are present in cooling systems a preliminary cleaning with the
emulsifying cleaning agent Careclean Degreaser GP is necessary.
Circulation Method
1. If present, remove zinc, aluminum, galvanized steel components before commencing the
cleaning operation.
2. Before cleaning with Careclean F Descalex P solution, we recommend thoroughly rinsing
with water. This will partly or completely remove loose sludge, scale, etc.
3. Depending on the nature of the scale and degree of contamination, it is recommend to use a
cleaning solution with a concentration of 3 - 10 kgs Careclean F Descalex P per 100 liters of
water. This solution can best be prepared by continuously stirring the powder into warm
water.
4. Solutions of Careclean F Descalex P may be heated to a maximum of 60o C, which will result
in a quicker cleaning process.
5. During the cleaning process, inflammable and/or toxic gases may be released, therefore
adequate ventilation must be provided. Avoid naked flames.
6. The length of the cleaning operation depends on the thickness and type of deposit and also on
the product concentration. Generally speaking this period will be within 24 hours.
7. After cleaning, drain off the solution and neutralize it with Careclean Alkaline Extra outside
the system.
8. The final rinsing can be carried out with a 1% solution of Careclean Alkaline Extra.
Properties:
Light brown colored powder containing inhibitors and sulphamic acid. Non-flammable and not
hygroscopic.
Flashpoint : None
pH (1% solution) : 1.5
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN HD DESCALEX L
Application
Careclean Descalex L is suitable for cleaning boiler's condensers, evaporators, heat exchangers,
cooling and pipe systems. It must not be used on zinc, aluminum, stainless steel, galvanized
materials or cast iron.
General
1) We recommend that a preliminary test is carried out on samples of the original scale or
deposit in order to select the most suitable acid cleaner and optimize product concentration
and temperature conditions.
2) Where a boiler is soiled with light oil deposits, or if silicates and/or calcium are present,
boiling out with Careclean Alkaline Extra is recommended.
3) If heavy mineral oil deposits are present in cooling system, a preliminary treatment with an
emulsifying cleaner, such as Careclean HD Split or Careclean HD is necessary.
4) If heavy oil deposits are present in cooling systems a preliminary treatment with the
emulsifying cleaning agent Careclean Degreaser GP is necessary.
Circulation method
1. Remove zinc, aluminium, cast, iron, galvanised and stainless steel components before
commencing the operation.
2. Before cleaning with Descalex L solution we recommend thorough rinsing with water. This
will partly or completely remove loose sludge, scale, etc.
3. Depending on the nature of the scale and degree of contamination, 1 Ltr. of Descalex L is
added to 4-9 Ltr. of water. Further dilution with water is not recommended as the excellent
inhibiting effect will be reduced.
4. Descalex L is normally used cold. However the solution may be heated to a maximum of 55
C which will result in a quicker cleaning process.
5. During the cleaning process inflammable and/or toxic gases may be released, therefore,
adquate ventilation must be provided. Avoid naked flames.
6. The length of the cleaning operation depends on the thickness and type of deposit and also
on the concentration of the product used. Generally speaking this period will be within 24
hours.
7. After cleaning drain off the cleaning solution and neutralise with Careclean Alkaline Extra
outside the system.
8. Rinse the system thoroughly with water until there is a neutral reaction on pH paper.
9. Finally rinse with a 1% solution of Careclean Alkaline Extra .
Circulating system
Marine Care provides a portable circulating pump and tank systems ideal for this product. Please
refer to the Marine Care equipment information sheet.
Properties
Light brown liquid containing hydrochloric acid, completely miscible with water. Low foaming.
Suitable for use on most common metals, except zinc, aluminum, cast iron,
stainless steel or galvanized materials.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN RUST
Acidic liquid product for the cleaning of aluminium, copper and removal of rust stains on
paint work.
Application
Careclean Rust is used for the cleaning of aluminium floor plates, copper and brass fittings, wooden
decks and the removal of lime after tank cleaning operations.
In most cases Careclean Rust is applied by brush diluted in solutions ranging from 10-50% and left
to react for 5-10 minutes. Smaller objects can be soaked in plastic container. After cleaning, rinse
items thoroughly with a water jet.
Paintwork
Dilute Careclean Rust 1 liter of product to 4-9 liters water, apply the solution by brush or spray
using plastic equipment and leave to soak for 10-20 minutes. Rinse off using a powerful water jet
with a brush, if necessary.
Tankcleaning
If lime scale stains are present after completion of tank cleaning operations, inject 0.5 liters
Careclean Rust per 100 liters washing water directly into the automatic washing system approx. 20
minutes. The recommended temperature is 75-85°C.
For detailed instructions on tankcleaning refer to the Marine Care Tank Cleaning Manual.
A range of support equipment is also available.
Properties
Colourless fluid contains phosphoric acid. Non-flammable and completely soluble in water. Within
the reaction time suitable for use on all metals and painted surfaces.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN SEPARATOR
Acid cleaning agent for cleaning stainless steel separator discs and separator bowl.
* A strong cleaning agent specially developed for cleaning stainless steel separator discs.
* Contaminants found on separator discs mostly consists of hardness salts (calcium
carbonate etc.) and partly carbonised oil. The combination of dissolving agents, acids and
surface active agents makes it possible to clean the separator discs quickly without
brushing.
* After cleaning the metal surface is passivated by the acid of the product.
Careclean Separator can only be used for cleaning stainless steel separator discs. Fill a stainless
steel or plastic container with pure Careclean Separator. Immerse the stainless steel discs in the
container and let the product act for 30 minutes up to a maximum of 2 hours. Heating the
product is not necessary. Do not put the discs closely packed into the liquid but take care that
there is enough space between them so that the product can work properly. Remove the discs
from the bath (wear rubber gloves) and rinse with a powerful waterjet. The cleaned separator
discs can be used immediately.
Properties
Careclean Separator is a colorless, strong acid, liquid cleaning agent with strong degreasing
properties. This product can only be used on austenitic stainless steel and is corrosive on all
other metals.
For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the result.
PRODUCT DATA SHEETS
- Corrosion -
CARETAN CORROSION
Rust converter for use on rusted steel and sandblasted steel as pre-coating preparation.
Application
On all rusted steel surfaces before painting or repainting when preparation by sandblasting is a
problem, e.g. cargo holds, decks, hatch covers, superstructures, pipelines, winches, rails etc. It is
also used on sandblasted surfaces to prevent or passivate "flash rust". Beyond being particularly
suitable for use in the highly corrosive marine atmosphere it is indeed also suitable for use on
offshore oilrigs, in shipyards and refineries.
Caretan Corrosion is ready to use. 1 single thin application is sufficient. Apply brush, roller or
spray. 1 liter covers approx. 20 square meters. Reaction time is 3 hours and paint/coatings must be
applied sooner. If the rustconverter is applied in confined areas, reaction time may be somewhat
longer.
Caretan Corrosion is not a paint. Treated surfaces must be protected by suitable paint/coatings,
preferably within 48 hours after application of Caretan Corrosion. Equipment should be washed
and flushed in clean water use.
CAUTION:
The rust converter should NOT be applied on hot surfaces above 40°C such as e.g. a deck area in
sunny tropical climate. Such areas should be treated only when the area has cooled down during
the evening and left for reaction overnight.
Properties
Caretan Corrosion is based on water reducible chelating polymers. Does NOT contain Phosphoric
Acid.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their applications lies outside our control
we cannot accept any liability for the results.
CARECOAT 402
• Contains no solvents.
• Requires no special surface preparation prior to application.
• Can be applied on rusted steel or new steel and is compatible with old deteriorated
coatings.
• Is highly polar with strong molecular affinity for metal surfaces.
• Is easy to use – only one coat required.
• Can be applied by airless spraying or by brush or roller.
• Repair works such as welding and other “hot work” jobs can be carried out without
removal of the coatings.
Application
Carecoat 402 ballast coating is recommended for recoating of completely ruted ballast tanks
in all types of vessels, also in peak tanks, offshore leg support tanks, cofferdams, floating
docks, caissons, void spaces ect. It is also suitable for application on new steel provided mill
scale has been removed.
Surface Preparations
1.) For ships in service: No special surface preparation such as wire brushing or
sandblasting is required prior to the application. However, it is necessary to remove
mud and silt, loose rust, loose scales, debris and loose paints. Usually a thorough high
pressure water wash with 200 bar pressure is sufficient, eventually followed with light
scraping of tank surfaces. It is not necessary that tank surfaces are dry prior to the
application of the coating.
2.) For Lloyd’s Register corrosion control notation in association with reduced scantlings
the surface preparation must be in accordance with BS 4232-2 equivalent to Swedish
Standard Sa 2½ (SIS-05-5900-1988) at new building stage.
Airless Spraying
Product may be applied by airless spray using 45:1 ratio, with nozzle sizes “25” (0.025”inch;
type 163-725) or “27” (type 163-727) both with 70° fan angle. The use of alternative nozzle
sizes depends on the viscosity of the coating during application. Check the material
temperature.
Application Temperature
Do not apply at temperatures below 5°C (41°F). The minimum coating material temperature
for spraying is 12°C (54°F). In cold weather preheating of Carecoat 402 ballast tank coating
may be necessary. However, it should not be heated to a temperature exceeding 60°C (140°F).
Properties
Dark brown clear semi-thixotropic liquid of anticorrosive chemical compounds with high
contents of woolgrease, lanolin and cationic surface-active components.
For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
PRODUCT DATA SHEETS
- Watertreatment -
CARETREAT 1 EVAPORATOR
Neutral, liquid product for the prevention of scaling in sea water evaporators
Introduction
In the production of distilled water in seawater evaporators, there are many conditions which can
cause scaling. In the evaporator, the seawater is heated to the required temperature and is then
partially evaporated at atmospheric or low pressure; it then condenses and is collected as distillate.
Since, however, the seawater contains large quantities of salt in solution it is understandable that the
heating and evaporation will very rapidly lead to scaling of the heat transfer surfaces. The scale
deposits build up and lower plant efficiency by severely impairing the transfer of heat. This in turn
considerably reduces the output. Scaling is prevented by the use of Caretreat 1 Evaporator.
If the product is used as part of the Marine Care Water Treatment program, production is monitored
as part of a "Water Management" system which includes useful information on maximizing plant
efficiency.
Caretreat 1 Evaporator is diluted with seawater andfresh water and is continuously injected into the
evaporator. A dosage of 30 ml per ton of distillate is recommended for the prevention of scaling in
seawater evaporators. The total dosage of Caretreat 1 Evaporator to be used depends on the capacity
and the operating conditions of the evaporator. The product should be injected via the evaporator
inlet or the salt water supply line. The normal procedure is to use a dosing tank containing sufficient
ready diluted Caretreat 1 Evaporator for 24 hours continuous operation.
Note: For the gradual removal of existing scale deposits, at least twice the normal dose must be used.
Remove deposits of more than 2mm, with Careclean HD Descalex L.
Dosing systems
Marine Care can supply a gravity dosing system kit which includes a dosing tank, flow meter, pipes,
valves and all fittings.
Properties
Light brown colored, neutral liquids. Miscible with salt and fresh water in any proportion.
Odorless, non-flammable.
Contains no volatile components; in practical terms, non-toxic when ingested in a single dose.
Remains fully effectively up to 160o C.
Does not corrode stainless steel, carbon steel, copper alloys, glass rubber, plastics, painted surfaces,
aluminium and aluminium alloys.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT 2 DIESEL
Diesel engine cooling water corrosion and scale inhibitor in liquid form, suitable for "closed
circuit" systems
Application
Caretreat 2 Diesel is a nitrite, borate and polymer based corrosion inhibitor with a suitable buffer to
ensure stable pH conditions. The formula has the U.K. Department of Trade approval for use in
cooling systems incorporating a fresh water generator producing fresh water for drinking purposes.
Caretreat 2 Diesel is used in a dosage of 1200 - 3000 mg/l nitrite (NO2), dependent on the chloride
level and engine type, please refer to the engine manufacturers instructions on recommended nitrite
ranges:
Dosing system
A compact electronic dosing pump and tank unit is available from Marine Care for direct injection
to the cooling system. For further details refer to Marine Care equipment information.
Remarks
On new buildings or overhauled systems, follow engine manufacturer's advice in conjunction with
Marine Care. If changing to Caretreat 2 Diesel from nitrite borate based products of another make,
start dosing Marine Care product using Marine Care tests. Caretreat 2 Diesel will slowly remove
sludge and other residues during first month. This can result in slightly cloudy water which will
clarify after draining small quantities of water and as make up is added, leaving system extremely
clean. It is not necessary to drain existing coolant completely unless inspection has shown
excessive contamination. Marine Care can give expert advice on cleaning systems.
Properties
Caretreat 2 Diesel is a pale yellow liquid, completly soluble in water. It is based on nitrite and
borate in combination with specific inhibitors, organic dispersants and a pH buffer. Compatible
with anti-freeze products based on monoethylene glycol.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
COOLING WATER TREATMENT TEST (CARETREAT 2 DIESEL)
NITRITE 1. Completely rinse the dropper to be used, then fill the dropper to the 0.5ml mark * INITIAL DOSAGE: 6 LTR/TON (NORMAL RATED)
with the sample and discharge into color viewing tube.
* LIMIT: 2. Fill the tube to the upper mark (=10ml) with demineralized water. 1. Normal rated engine
3. Divide the diluted sample equally between the color viewing tubes (each) 5ml.
1. NORMAL RATE Add 1Nitriver 2 reagent powder pillow to one of the tubes, and stopper & mix PPM DOSAGE
1200-2000ppm well. If nitrite is present a greenisch/brown color will develop. Allow 10 min. 200 5.3 ltr
2. HIGH RATE for HIGH 4. Place the tube prepared with Nitriver 2 in the right position of comparator, and 400 4.5 ltr
SPEED ENGINE: the other tube place to the left. 600 3.8 ltr
2500-3000ppm Rotating disc of comparator until a color match is obtained. 800 3.0 ltr
1000 2.3 ltr
** SCALE READING x 20 = PPM AMOUNT 1200 1.5 ltr
** PH: 9-10
CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. UP TO 100PPM: SATISFACTORY
Pour the contents of the tube into the mixing bottle.
(Limit: up to 100ppm) 2. Fill the bottle with distilled water up to 15ml Over 100PPM: Partly drain and dose Caretreat 2 Diesel
3. Add 1 Chloride 2 indicator powder pillow and mix well. accordingly.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color
*** TEST KIT 1. TEST SET FOR NITRITE 2. CHLORIDE TEST KIT 3. PH PAPER ***
DIESEL ENGINE COOLING WATER GRAPHIC LOG
Date: M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
Nitrate Level Main Engine: ** To increase Care 2 level by 100 ppm NO2 add 0,4 Ltr/ M3 Submitted by:
Between 1200 - 2000 PPM NO2
Nitrate Level Aux. Engine: Remarks: Approved by
Between 2500 - 3000 PPM NO2 Ch. Engineer
CARETREAT 3 BOILER
Advanced organic boiler water treatment to control ph, corrosion, scale and sludge.
Introduction
Caretreat 3 Boiler has been developed to meet the demands for a modern, practical boiler water
treatment. Caretreat 3 Boiler is a dark brown liquid based on neutralized organic acids, pH, corrosion,
scale and sludge conditioners.
The neutralized organic acids remove nominal oxygen presence and inhibit the boiler corrosion forming
an organic iron compound. The correct pH is maintained by a unique blend of low molecular weight
compounds which avoid pitting corrosion caused by chlorides. Use of these compounds also avoids
"under deposit" corrosion which is caused by excess alkalinity in conventional treatment.
A blend of advanced polymers stops the formation of scale and maintains clean surfaces in the boiler.
These conditions are maintained with a low total solids level, avoiding heavy sludge, making blow
down of the boiler more efficient.
Application
Control limits
Intial dosage
Caretreat 3 Boiler is dosed at 0,4 litres per metric ton boiler water. Allow the boiler water to be
conditioned for 24 hours and then carry out a p-alkalinity test. Adjust product dosage as necessary to
obtain a p-alkalinity of 100 - 200 ppm.
At the same time determine the chloride content. If the chlorides are too high, give the boiler a top and
bottom blow down in a ratio in time 2 to 1.
Daily dosage
Recheck p-alkalinity and increase dosage of Caretreat 3 Boiler if necessary to maintain pH or p-
alkalinity level. A minimum of 0,2 ltr/day should be dosed to maintain correct treatment levels in
conjunction with regular top and bottom blown down. This dosage can vary according eg. size of the
boiler system, make up water quality etc.
Properties
Caretreat 3 Boiler is a dark brown liquid containing neutralized organic acids, pH, corrosion, scale and
sludge conditioners. After using the treatment the boiler water will be clear and straw coloured.
Specific gravity : 1.21 (20o C)
Flash point PM CC : None
pH (1 % solution) : 13
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
BOILER WATER TREATMENT TEST (CARETREAT 3 BOILER & CARETREAT 4 CONDENSATE)
P-ALKALINITY 1. Completely fill the plastic measuring tube with boiler water. ** CARETREAT 3 BOILER **
Pour the contents of the tube into the mixing bottle.
* (Limit: 100-200ppm) 2. Fill the bottle with distilled water up to 15ml * Initial dosage: 0.75 ltr/ ton
3. Add 1 phenolphtalein indicator powder pillow to the mixing bottle and mix
4. A pink color will appear (if colorless, P-Alkalinity is zero). * Over 200ppm p-Alkalinity - decrease dosage by 25%
Add drop by drop sulphuric acid standard solution counting the number of drops, * p-Alkalinity level between 100-200ppm - satisfactory.
untill the solutions is colorless. * Below 100ppm p-Alkalinity - increase dosage by 25%
CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. *Up to 200ppm: satisfactory
Pour the contents of the tube into the mixing bottle.
* (Limit: up to 300ppm) 2. Fill the bottle with distilled water up to 15ml * Over 200ppm: blowdown
3. Add 1 Chloride 2 indicator powder pillow and mix well.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color
CONDENSATE PH 1. Take condensate water sample, and immerse pH paper. ** CARETREAT 4 CONDENSATE **
2. Read the pH value..
* (Limit: pH 9-9.5) * Initial dosage: 0.2 ltr/ ton
* 0.4 ltr/ 24 hours - normal daily dosage
*** TEST KIT 1. TEST SET FOR P-ALKALINITY 2. CHLORIDE TEST KIT 3. PH PAPER ***
BOILER WATER GRAPHIC LOG
Date:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
350
300
250 Decrease Dosage 10%
200
150 Ideal
100
50 Increase Dosage 25%
0
CHLORIDES / ppm C1
210
180
150
120
90
60
30
0
CONDENSATE / pH
10.0 Decrease Care 4 Dosage 10%
9.5 Ideal
9.0
8.5 Increase Care 4 Dosage 25%
An organic oxygen scavenger and corrosion inhibitor for feed, steam and condensate systems
Introduction
Caretreat 4 Condensate is an oxygen scavenger based on neutralized organic acids and a blend of
volatile/neutralizing amines. It is normally used only in conjunction with Caretreat 3 Boiler as part of
the water treatment program. It removes oxygen efficiently in open feed systems and gives effective
corrosion inhibition of boiler/exhaust gas economizer system surfaces by converting Fe203 (rust) to an
organic iron compound. It also protects copper based metals. The amines pass over with the steam and
have the dual function of elevating the pH of the steam/condensate and putting a protective micro film
on the system pipe work. Acidic condensate is the result of carbonic acid (H2C03) being formed as CO2
is released in the steam. The use of Caretreat 4 Condensate prevents corrosion by carbonic acid on live
systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are
present.
Caretreat 4 Condensate is dosed at a rate which maintains a pH of 9.0 to 10.0 in the condensate returns.
Oxygen entrainment largely depends on Hotwell temperatures and if these are maintained at above 80o
C the condensate pH range of pH 9.0 to 9.5 is adequate. If Hotwell temperature control is erratic and
averages less than 80o C, tighter control is necessary and condensate returns should be kept in the range
pH 9.5 to 10.0. It is not necessary to carry out oxygen or product residual tests.
Initial dosage
Caretreat 4 Condensate is initially dosed at 0,2 ltr/m3 boiler water. Systems showing signs of corrosion
should be dosed at up to .07 ltr/m3 boiler water for the first few days in order to passivate all metal
surfaces.
Daily dosage rates
After initial dose, start metering at a minimum of 0.4 ltr/24 hours continuously and adjust to obtain
correct condensate pH.
Dosing system
Caretreat 4 Condensate must be dosed continuously in conjunction with Caretreat 3 Boiler in a
metering pump/tank unit, discharging directly into the feed system and/or the exhaust gas economizer
circulating pump discharge. It must NEVER be slug dosed to a running system via a Hotwell or by-pass
feeder. For further details on dosing equipment refer to the equipment information sheets.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT 5 SEAWATER
Disperses marine growth and reduces corrosion in sea water cooling systems, tanks and sea
water systems
* Prevents and controls marine growth in once-through sea water cooling systems.
* Protects system from corrosion by filming properties.
* Being biodegradable and not oil-based, its use does not contravene regulations limiting oil in
discharge water.
* The formula is approved by the U.K. Department of the Envirement for use at a dose rate not
exceeding 8 ppm for sea water pipelines feeding evaporators producing water for potable
purpose
* Has clearance of major international environmental control departments for discharge into
harbour and sea.
* Empty tanks remain protected for several days.
Introduction
Caretreat 5 Seawater has been designed to effectively stop the development of micro organisms, shell
embryo, bacteria and plant life commonly found in sea water. Most fouling of ships systems is
primarily the result of microscopic organisms colonising in the pipework, attracting growth of larger
lifeforms and giving anchorage to sand and silt. Partial blockage of heat exchanger tubes reduces flow,
resulting in local overheating and subsequent scaling from hardness salts.
Dosage instructions
Example : system of 250 tons/h.
Dosage method
Using the Caretreat 5 Seawater Dosing System to high and low boxes via stop valve and non-return
valve. Extension tube mounted inside box, out to grid. For further details refer to the Marine Care
equipment information sheet.
Dosage routine
A. Calculate amount of Caretreat 5 Seawater for each dose. i.e. 250 tons per hour x 0.006 litre =
1.5 litres/dose.
B. If using a dosing system which requires dilution of Caretreat 5 Seawater with water never add
water to the product. Always mix the product into the water, stirring continuously.
C. On approaching shelf or coastal area, open discharge valves to operating chest and operate
system for 1 hour.
D. Close system valves.
E. Make note of date and which box dosed.
F. If changing to high level suction remember to dose to the correct box.
G. When leaving area (dockside, estuary, coast or shelf area) continue dosing on 2 day cycle so
that last dose is after clearing shallow waters.
2. Tanks
Inject Caretreat 5 Seawater into sea water at 45 - 130 ml per m3 water capacity.
3. Pipelines
Dose at 100 ppm by injecting 80 x D-ltrs per kilometer of pipeline. (D = pipe diameter, in meters).
If fresh water is used for either applicaion lower concentrations may be used.
Properties
Cloudy yellowish-brown aqueous liquid containing dispersants with filming properties. In concentrati-
ons less than 10 % miscible with water.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT POTABLE WATER TREATMENT
INTRODUCTION
APPLICATION
Dosage instructions
Initial dosage:
Inject the product at a rate of 50 ml. per m3 water.
Use the same rate (50 ml/m3 water) for slug dosing tanks.
Continuing dosage:
Within a short period water outlets on the vessel will become clear.
At this time, reduce the dosage to 25 ml. per m3 water.
Dilution of product : 60 : 1
For further details on dosing units refer to the equipment information sheets.
PROPERTIES
In accordance with the latest E.E.C. Council directives this product is not subject to any
official recommendations.
The details of our products are given completely free of undertaking. Since their application
lies outside our control we cannot accept any liability for the results.
PRODUCT DATA SHEETS
Caretreat Sludge is an oil soluble and self dispersing fuel oil treatment primarily
formulated to combat problems in the pre-combustion stage with oil used in marine
diesel engines and boiler plants.
Application
Caretreat Sludge is easy to use. The required amount is introduced into the bunker tanks
simply by pumping it through the sounding pipes prior to oil bunkering. The turbulence
created by the subsequent bunkering will, together with the incorporated dispersants, ensure
complete mixing and further distribution of the treatment uniformly throughout the fuel.
Dosages
To obtain the benefits of the chemical treatment to the entire fuel oil system it is necessary to
dose the product in the most appropriate ratio depending upon the nature and severity of the
problem.
If Caretreat Sludge is not used regularly an initial dosage of 1:4000 should be used for
breaking up and dispersing existing sludge. For counteracting the effects of incompatible fuels
(stratification) a dosage as high as 1:2000 may be necessary.
Properties
Clear yellow liquid with a characteristic smell, containing solvents, special detergents and
dispersants. Contains no chlorinated solvents or other harmful ingredients.
Specific gravity (20%) : 0.86
Flash point PMCC : over 62°C
Viscosity : approx. 10mPas
Storage
Maximum storage temperature : + 50°C
Minimum storage temperature : - 20°C
For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARETREAT COMBUSTION
The latest development of a fuel oil treatment acting as a combustion improver, carbon
catalyst, ash deposits modifier and smoke suppressant for diesel engines and boilers.
Application
Caretreat Combustion is a concentrated product, especially formulated to treat heavy fuel oil in
diesel engines and boilers.
Dosing
Dosage point location varies depending on engine/boiler fuel system layout. The most efficient
and economical method is obtained with a metering pump, dosing the additive into the suction
side of the booster pump (for diesel engines) or into the burner feed line (for boilers).
Alternatively the additive may be dosed directly to the day tank prior to refilling or directly to
the bunker tanks.
Dosage rates are depending upon engine characteristics, operating conditions and quality of
fuel oil. A CCAI (Calculated Carbon Aromaticity Index) number exceeding 840 indicated a
poor fuel oil quality which justifies the use of a chemical fuel oil treatment to counteract the
effects hereof.
Typical dosage rate varies between 1:1000, 1:6000 and 1:12000. Consult your local Marine
Care Service Engineer for recommendations of the dosage rate based on specific problems and
requirements onboard.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT ECONOMIZER
Introduction
Todays main propulsion units have low exhaust gas outlet temperatures. This is due to increased
engine and turbo blower efficiency. Lower gas temperatures are also the result of running at
reduced power. The low temperature and reduced gas volume gives increased soot deposition
and subsequent corrosion.
The increased deposition greatly reduces the thermal efficiency of the economizer. As "dew
point" is often reached in the unit, causing the generation of sulphuric acid, the corrosion process
is greatly accelerated.
Caretreat Economizer is a specially developed liquid which is easily dosed into the system, using
a special Marine Care injection unit. The special air assisted nozzles create a fine mist so that the
liquid vaporises on contact with the hot gas.
The vapor mixes intimately with the exhaust gases and the active material is dispersed
throughout the system in microscopic particles. These tiny particles have an extremely large
"active surface area" and being light, remain in the gas fully dispersed. This ensures that all parts
of the economiser are covered efficiently.
Caretreat Economizer catalyses the post combustion process, resulting in modified soot particles
which are dry and non adherent. The resulting deposit is more friable and can be more easily
removed by the action of the sootblowers.
Dosage instruction
1-2 litres of Economizer is required for every 1000 m2 of heating surface area. This amount
should be increased / decreased dependant on economizer design and fuel consumption.
Dosage period
Caretreat Economizer should be injected daily or twice daily after sootblowing.
Dosing equipment
The product must be dosed via the specially developed Marine Care injection unit which is made
of materials suitable for prolonged contact with Caretreat Economizer. For further information
please refer to the Marine Care equipment information sheet.
Injection points
In most cases a single injector can be put into the exhaust systems immediately after the turbo
charger gas outlet. Marine Care engineers will inspect and make detailed recommendations for
exact positioning.
Properties
Yellowish coloured neutral product containing special metal salts. Fully miscible with water.
For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARETREAT VALVES
Application
Caretreat Valves has been formulated primarily for use in 2-cycle and 4-cycle medium
speed diesel engines which are highly turbocharged and in which premature exhaust valve
failure is a frequent problem.
Dosage
Dosage point location varies depending on engine fuel system layout. The most efficient
and economical dosing method is obtained with a metering pump, dosing the additive as
near to the oil injection point as possible, f.inst. to the suction side of the booster pump.
Dosage rates are depending upon engine characteristics, operating conditions and
especially the quality of fuel oil. Consult your local Marine Care Service Engineer for
recommendation of dosage, etc. based on specific problems and requirements onboard.
Guide for approximate dosage rates:
The combination between the various constituents changes with each bunker supply. It is
therefore imperative that dosages are set for the worst case, viz. the highest value of any of
the above fuel oil
constituents.
Properties
Caretreat Valves is a light brown coloured liquid containing oil soluble organo-metallic
compounds, special solvents, emulsion breakers, anti-oxidants, anti-corrosive agents,
combustion catalyst and dispersants. Compatible with all types of fuel oil.
In accordance with the latest E.E.C. Council directives this product is not subjected to any
official recommendations.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARETREAT SOOT
APPLICATION
The modified sulphur oxides combine with vanadium compounds and prevent the formation of
harmful low melting point sodium vanadyl vanadates.
Caretreat Soot greatly improves sootblowing efficiency and makes boiler cleaning an easier task.
Dosage
Initial dosage for dirty boilers should start at 130 gr. per m³ fuel burnt in 24 hours.
The calculated dose should be divided into 3 equal parts and dosed at 8 hour intervals. As
conditions improve the dosage can be progressively reduced to a minimum of 30 gr. per m³ fuel
burnt in 24 hours.
Once every 24 hours soot should be blown at least 1 hour after the last injection of Caretreat
Soot.
If a boiler has never been treated and is very dirty, double the initial figures can be used for the
first 2 weeks.
Injection
An air operated powder injector can be supplied by Marine Care. Its discharge tube should be put
through a combustion chamber sighting orifice or a special dosing access point. If possible, the
injection should be changed frequently to assist distribution throughout the boiler.
PROPERTIES
For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
PRODUCT DATA SHEETS
Application
Caretank ECO is designed for the removal of: heavy mineral oils and greases, dopes, additives, lubricants,
asphalt, distillation residues, coal tar, several synthetic resins, paraffines (e.g. slackwax), inert gas soot,
vegetable-, fish- and animal oils and fats, fatty acid and greases, crude palm oil, styrene, palm fatty acids.
Directions of use
Prewash
Before cleaning with Caretank ECO, it is necessary to prewash the tanks with hot or cold water, depending
on the type of cargo.
Recirculation method
Caretank ECO is added to a mixing tank containing sufficient quantity of water in order to obtain a good
recirculation.
The water is heated by means of the heating coils, cargo heat exchanger or butterworth heater.
The tanks are washed by means of a loading pump, after which the solution used is recycled to the mixing
tank. One solution is most often used to wash 1 – 4 tanks.
Caretank ECO must be recirculated as a 0.2 – 0.5 % emulsion (dependent on the nature of the
contamination). Allow this emulsion to circulate for 2 – 4 hours at the temperature of 10-60 °C (depending
on type of cargo).
Direct Injection
Inject 0.1 to 0.2 litres of Caretank ECO per every 100 litres of water into the washing system.
Maintain cleaning temperatures between 10-60 °C (depending on type of cargo).
Cleaning time 2 to 6 hours, followed by thorough rinsing with fresh hot water.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN ALKALINE
• Removes vegetable and animal oils, fatty acid and greases, whether or not hardened or
carbonised.
• Applicable at low temperatures.
• Works effectively.
Application
Careclean Alkaline contains besides non-ionogene surface-active components and alkaline salts
even effective solvents. This makes the products well applicable at lower temperatures (20-60oC)
by means of some circulation. Careclean Alkaline is suited to remove vegetable and animal oils
and greases, whether or not hardened or coarbonised. Careclean Alkaline is not suited to use on
zinc silicate coatings and most paints/laquers. Diluted with water to a solution of maxium 10%
and at a temperature of maximum 60oC, the product is safe to use on epoxy-coatings. It is suited to
use on most metals except for aluminium, tin, zinc and galvanised material.
Prewashing
Prior to cleaning with Careclean Alkaline, it is advised to wash with hot water of approximately
80oC. In case of drying and semi-drying oils, prewashing is to be done with cold water.
Immersion bath
For slight oil-contaminations Careclean Alkaline can be diluted with water to a 10% solution.
Heaten the liquid with a heating coil or by means of steam injection to 20-60oC. Place the objects
to be cleaned in the bath and allow several hours working time. Afterwards brush the objects while
rinsing them with a powerful waterjet. In case of heavily contaminated objects, Careclean Alkaline
is applied undiluted in immersion bathes, for example to remove old paint layers to and to clean
oil and grease filters, deep fry equipment, baking ovens etc.
Spraying
Depending on the amount and character of the contamination, Careclean Alkaline is to be used
pure or diluted at a temperature of 20 - 60oC. Allow the product to work for 20 to 60 minutes and
spray afterwards with a powerful high pressure waterjet. Warm water is to be preferred.
Recirculation
With this method, the cleaning chemicals are added to a prior determined amount of cleaning
chemicals is usually 1% of the capacity of the tank is to be cleaned.
Properties
Light brown liquid. Very alkaline, contains potassium hydroxide. Suited to use on most metals,
but is not to be used on tin, aluminium, zinc silicate coatings.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN ALKALINE EXTRA
Strong alkaline liquid degreasing agent for the removal of vegetable, fish and animal oils and
fats from epoxy / polyurethane coated or stainless steel tanks by injection or circulation
method.
* Very powerful alkaline cleaning agent based on strong anionic surface active agents and
alkaline salts.
* Thorough saponification and emulsification provides economic removal of vegetable and
animal oils.
* Can be used on most common metals except aluminium, tin, zinc and galvanised metals.
* Safe to use on epoxy and polyurethane coatings but it is not suitable for use on zinc silicate
coatings, most paints and lacquers (For zinc silicate coating we advice the use of Careclean
Neutral HCF).
* Deodorises certain residues.
Application
Steam boilers
Prior to acid cleaning of steam boilers which are also contaminated with oil and grease or when
silicates/calcium sulfates are present it is advantageous to first perform a boil out operation with
Careclean Alkaline Extra.
Tanks
Suitable for the removal of fatty acids, fish oils and other drying or semi drying oil deposits present
as deposits in storage and loading tanks. It is very effective on dried oil films. When cleaning from
"black" to "white" and from "black" to grain it is a useful final treatment.
For detailed instruction on tankcleaning refer to the Careclean Tank Cleaning Manual.
A range of support equipment is also available.
Properties
Strong Alkaline liquid. suitable for use on epoxy coatings and most common metals except
aluminium, tin, zinc, galvanised materials and zinc silicate coatings.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN RUST
Acidic liquid product for the cleaning of aluminium, copper and removal of rust stains on
paint work.
Application
Careclean Rust is used for the cleaning of aluminium floor plates, copper and brass fittings, wooden
decks and the removal of lime after tank cleaning operations.
In most cases Careclean Rust is applied by brush diluted in solutions ranging from 10-50% and left
to react for 5-10 minutes. Smaller objects can be soaked in plastic container. After cleaning, rinse
items thoroughly with a water jet.
Paintwork
Dilute Careclean Rust 1 liter of product to 4-9 liters water, apply the solution by brush or spray
using plastic equipment and leave to soak for 10-20 minutes. Rinse off using a powerful water jet
with a brush, if necessary.
Tankcleaning
If lime scale stains are present after completion of tank cleaning operations, inject 0.5 liters
Careclean Rust per 100 liters washing water directly into the automatic washing system approx. 20
minutes. The recommended temperature is 75-85°C.
For detailed instructions on tankcleaning refer to the Marine Care Tank Cleaning Manual.
A range of support equipment is also available.
Properties
Colourless fluid contains phosphoric acid. Non-flammable and completely soluble in water. Within
the reaction time suitable for use on all metals and painted surfaces.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN NEUTRAL HCF
Universal neutral liquid degreaser for the removal of vegetable oils and animal oils and fats
from zinc-silicate coated tanks.
• Neutral cleaning product based on highly efficient dissolving and low foaming nonionic
surface active agents.
• Expecially developed for the removal of vegetable, animal and mineral oils as well as fats
where cleaning with Careclean Alkaline Extra or Careclean Alkaline is not possible.
• Suitable for cleaning tanks coated with zinc-silicate and all common metals.
Application
1. Careclean Neutral HCF can be used for the removal of vegetable and/or animal oils and fats
and light mineral oils in aluminium and/or zinc-silicate coated tanks.
2. Careclean Neutral HCF can be used as an after treatment agent in hydrocarbon free cleaning
operations where cleaning has been carried out with e.g. Careclean Degreaser HD or Careclean
Degreaser GP.
Cleaning of tanks
Prewash before cleaning with Careclean Neutral HCF it is recommended to prewash with hot water
at 50°C. For drying and semi-drying oils a prewash with cold water should be carried out
immediately after discharge of cargo to retard oxidation and hardening of oil residues.
Recirculation method
A chemical solution is prepared in an empty slop tank or one of the after tanks near the pump room,
circulated via the automatic tank washing system pump and heater to the tank to be cleaned,
wherefrom the solution is returned to the chemical solution tank via the stripping line. Usually it is
not possible to recirculate the chemical solution through the tank washing system heater (to
maintian solution temperature) without making a temporary connection between the chemical
solution tank and the tank washing pump. Capacities of solution tank, pipeline and pumps etc.
should be calculated carefully to ensure sufficient volumetric quantity for a continuous
recirculation.
Depending on size and condition of tanks to be cleaned and quantity of chemical solution, a
drawback in this method is that usually only 3 (three) tanks can be cleaned with one solution after
which a fresh solution should be made and heated before cleaning can continue.
Depending on the degree of contamination Careclean Neutral HCF is circulated as a 2-3% solution
for a periood of 2-6 hours. The water temperature should be approx. 20-60 °C. After the circulation
period rinse thoroughly with water.
Spray method
Spray the hot tanksurfaces with undiluted Careclean Neutral HCF until the surfaces are well soaked
and let the product act for at least 30 min. Then rinse all tank surfaces with water at max. 60°C for
45 minutes.
Hydrocarbonfree cleaning
Hand spray Careclean Neutral HCF on the hot tanksurfaces and let it act for 30 minutes.
Rinse thoroughly with hot chloride free water when cleaning is completed. If fresh water is used,
steam tanks afterwards to remove any chlorides which may cause delay in passing the chloride test
for methanol etc.
For detailed instructions on tank cleaning refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.
Properties
Neutral colourless liquid with a characteristic odour. Completely miscible with sea water and fresh
water. Suitable for use on zinc-silicate coatings and most common metals. Limited application on
epoxy coatings (maximum concentration 10% and maximum temperature 60°C)
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER GP
Emulsifying cleaning agent for the removal of medium to heavy mineral oils and fats by
spraying and brushing.
Application
Cooling systems
Along with the usual lime deposits, traces of mineral oils are often found in cooling systems.
These oil and fat deposits hinder optimum removal of the hardness deposits when using acid
cleaners (e.g.Careclean F Descalex P). In such cases, it is recommended to use an emulsifying
cleaner before the acid cleaning, to remove these deposits. Careclean Degreaser GP is ideal in
these cases.
Spraying
Careclean Degreaser GP can be sprayed undiluted onto the components to be cleaned.
Tanks
Careclean Degreaser GP can be used for the removal of most mineral oils and fats in loading and
storage tanks.
Note: Objects subject to corrosion should not be rinsed with water; use in this case, for example,
Careclean ECS Quick Dry.
Cleaning of tanks
Prewash
Before cleaning with Careclean Degreaser GP it is recommended to prewash with hot water at
approximately 60o C, except for drying and semi-drying oils where a prewash with cold water
should be applied.
Spray method
Spray the tank with undiluted Careclean Degreaser GP until the walls are thoroughly dampened
and then let the product soak in for at least 30 minutes. Rinse each tank compartment for 45
minutes with water at 60oC.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A
range of support equipment is also available.
Properties:
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN DEGREASER HD
Emulsifying cleaning agent with a high flash point for the removal of crude oil, bitumen,
paraffin and similar substances by circulation method
• Emulsifying cleaning agent based on aromatic solvents, anionic and nonionic surface active
agents.
• Specific solvents with high boiling and flash points.
• Ideally suitable for the removal of crude oil, bitumen, paraffin and other high melting point
stains.
• Can be used undiluted up to 80°C.
• Safe for use on most common metals, epoxy, polyurethane and zinc silicate coatings.
Application
Heavily Contaminated Steam Boilers. Scale in steam boilers where heavy oil contamination is
present, will not easily be removed by acid cleaners. In such cases, Careclean Degreaser HD is used
first to remove oil and grease before the acid cleaner is applied.
Tanks
Careclean Degreaser HD can be used to clean heavy oil, crude oil, bitumen, paraffin and other stains
having a high melting point in which cases a high cleaning temperature is necessary.
Cleaning of tanks
Prewash
Before cleaning with Careclean Degreaser HD, it is recommended to pre-wash with hot water at
approximately 50o C. For drying and semi-drying oils a pre-wash with cold water should be applied.
Recirculation method
Careclean Degreaser HD is added to a mixing tank containing a quantity of water which amounts to
1% of the capacity of the tank to be cleaned. The water is heated by means of the heating coils in the
tanks.
The tanks are washed by means of a loading pump, after which the solution used is recycled to the
mixing tank. One solution is most often used to wash 2 - 3 tanks.
Careclean Degreaser HD must be circulated as a 2-6% emulsion. Allow this emulsion to circulate
fodr 2 - 6 hours at a temperature ranging from 50 - 90o C.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.
Properties
Light yellow colored neutral liquid. Emulsifiable with water. Non-corrosive on common metal.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN DEGREASER
HEAVY DUTY SPLIT
A cleaning agent with excellent separating properties for the removal of mineral oils and
similar residual sediments.
Application
A) Degreasing
1) General cleaning
Dependant upon the degree of contamination Careclean Degreaser Heavy Duty Split can be
used pure, or diluted with water as a 2 to 20% emulsion at temperatures of 20 - 50 °C. After
cleaning rinse with water.
Note: When making up an emulsion always add the product to the water in that order, whilst
stirring constantly.
2) Floorplate maintenance
Careclean Degreaser Heavy Duty Split should be used undiluted when cleaning decks and
floorplates. Spray the area to be cleaned with full strength product and allow to soak for
between 10 to 30 minutes. Brush the treated surface occasionally and finally rinse with
water.
Important note: Before commencing any cleaning all rubber type sealing rings etc. should
be tested for compability with the cleaning solution.
B) Tank Cleaning
1) Prewash
Before cleaning with Careclean Heavy Duty Split it is recommended to prewash with hot
water at approx. 50°C, except for drying and semi-drying oils where a prewash with cold
water should be used.
2) Recirculation method
In this method Careclean Degreaser Heavy Duty Split is added to a separate tank containing a
previously determined quantity of water. The quantity of water required for cleaning the tank
usually amounts to 1% of the capacity of the tank to be cleaned.
The solution is heated by means of heating coils in the tanks. The tanks are washed using a
cargo pump after which the used solution is recycled to the mixing tank. In the
recirculation method use is often made of the sloptank for the preparation of the cleaning
solution. One solution is normally used to wash 2-3 tanks after which a new batch must be
prepared. Careclean Heavy Duty Split must be circulated as a 2-6% emulsion.
Allow this emulsion to circulate for 1-3 hours at a temperature of between 20-50°C. After
the circulation period, rinse thoroughly with water.
3) Spray method
Spray the tank walls with undiluted Careclean Heavy Duty Split until they are thoroughly
dampened. Allow the product to soak for at least 30 minutes. Rinse each tank compartment
for 45 minutes with water at 60°C.
4) Spot Cleaning
For spot cleaning, use the manual Spraying method described above. However, Careclean
Heavy Duty Split is not suitable for hydrocarbon free cleaning operations. In such cases it is
recommended to use Neutral HCF. For detailed instructions on tank cleaning refer to the
Marine Care Tankcleaning Manual.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARECLEAN VOYAGE (SEACLEAN)
Strong emulsifying cleaning agent for the removal of heavy crude oil, soot, ashpalt and carbon
black stains, by direct injection, Voyage method, spraying and/or recirculation-METHOD.
Application
Tanks
Careclean voyage can be used for the removal of most mineral oils and fats in cargo and storage
tanks.
Directions of use
Prewash
Before cleaning with Careclean voyage, it is recommended to prewash tanks with hot water of
approximately 50° C except for crude oil drying and semi-drying oils where a prewash with cold
water should be applied.
Recirculation method
A chemical solution is prepared in one of the after tanks near the pump room. circulated via the
automatic tank washing system pump and heater to the tank to the cleaned, wherefrom the solution is
returned to the chemical solution tank via the stripping line. Usually it is not possible to recirculate
solution through the tank washing system heater (to maintain solution temperature) without making a
temporary connection between the chemical solution tank and the tank washing pump.
Capacities of solution tank, pipelines and pumps etc. should be calculated carefully to ensure
sufficent volumetric quantity for a continuous recirculation. Depending on size and condition of
tanks to be cleaned and quantity of chemical solution a drawback in this method is that usually only 3
(three) tanks can be cleaned with one solution after which a fresh solution should be made and heated
before cleaning can continue. The required solution strength is 2 - 6 % Careclean Voyage.
After chemical cleaning the tanks should be rinsed thoroughly with sea water of fresh water
depending on availability and requirements.
Tank
1. Heat tank to higher than normal temperature, pump out as much fuel as possible and trim
vessel to ensure complete stripping.
2. Close all valves on engine room manifold.
3. Introduce first dose of Careclean voyage, through the sounding pipe, in accordance with the
dosage table stated below and fill the tank to 25% of its capacity with sea water. For filling
the tanks it is adviced not to use the ballast lines as they may contain fuel oil making the
cleaning more difficult.
4. Heat cleaning solution to minimum 60°C and maintain temperature for 48 hours. If heating
coils are not available, live steam may be used for heating the solution and maintain
temperature.
5. Empty tanks completely, fill to 50% capacity and empty again. Where single stage cleaning is
used the previous steps are ignored.
6. Add second dose of Careclean voyage and fill tank with sea water to 50% of its capacity,
continue heating and maintain at this level for 48 hours.
7. Add further sea water to fill tank to 75% capacity, continue heating and maintain for another
48 hours.
8. Empty tanks and pressure rinse with clean water through sounding pipes for 1-1 hour under
continuous stripping. Pressure should be kept as high as safety permits.
9. When rinsing is completed stop discharge (stripping) pump and fill tank until clear water runs
from sounding pipes on deck.
10. Stop water supply and empty (strip) tank. Trim vessel to ensure complete stripping.
Note: If tanks are not serverely contamined and/or the fuel oil viscosity is lower than 180 cSt at
50°C th cleaning process should be in one stage using step 5-10 only.
Properties
Highly concentrated blend of aromatic solvents emulsifiers and surface active ingredients. Light
yellow coloured neutral liquid. Emulsifiable with water to a maximum of 50%. Undiluted at room
temperature or in emulsions with water up to 6% at a maximum temperature of 60°C it can also be
used on plastic materials, epoxy and zinc silicate coatings.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
Dosage table of Careclean voyage
2-5 2 4 6
5 4 8 12
10 8 16 24
15 12 24 36
20 16 32 48
25 20 40 60
30 24 48 72
40 32 64 96
50 40 80 120
75 60 120 180
100 80 160 240
200 160 320 480
250 200 400 600
300 240 480 720
400 320 640 960
500 400 800 1200
600 480 960 1440
700 560 1120 1680
800 640 1280 1920
900 720 1440 2160
1000 800 1600 2400
For detailed instructions on tank cleaning, refer to the Marine Care Voyage. A range of support
equipment is also available.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN MULTICLEANER
* Powerfull cleaner
* For general and tankcleaning
* No organic solvents
* Non flammable
* Suitable for most surfaces
Properties
Careclean Multiclean is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN AQUAWASH
* Bio degradable
* Mineral oil free
* No organic solvents
* Non flammable
* Suitable for most surfaces
Spraying
For contamination, Careclean Aquawash is sprayed on undiluted and left for 20 - 60 minutes. It
must then be hosed off with a powerful waterjet, whilst brushing the surfaces.
General cleaning
Careclean Aquawash can be diluted to a 2% solution in water for light cleaning. It must be
allowed to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product
is increased by using water at a temperature of 20 up to 60°C for dilution and rinsing.
Properties
Careclean Aquawash is a green coloured liquid which contains anionic and nonionic surface
active agents and complexing agents. It can be used on most common metals, synthetic materials,
rubber and hardened paints and lacquers.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN GP ENVIRO
Application
Careclean GP Enviro is used for engine rooms, decks, bulkheads and accommodation.
General Cleaning
Careclean GP Enviro can be diluted to a 2% solution in water for light cleaning. It must be allowed
to soak for 1-15 minutes before rinsing with a waterjet. The effectiveness of the product is increased
by using water at a temperature of 20 up to 60o C for dilution and rinsing.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN COALTAR
Emulsifying cleaning agent for the removal of coaltar, crude benzene pyrolyse gas oil,
bitumen and similar substances
• Effective cleaner which will not leave carbon residues on the cleaned surface.
• Excellent for heavily contaminated heat exchangers.
• Economical cleaner which can be used as an emulsion with seawater.
• Minimizes waste waters, because of fast separating properties (product + contamination sink to
the bottom of separation tank because of its specific gravity.
Application
Careclean Coaltar is used for cleaning of tanks, heat exchangers, air coolers etc.
For detailed instructions on tank cleaning, refer to the Marine Care Tank Cleaning Manual. A range
of support equipment is also available.
For cleaning of heat exchangers, etc.:
1.) Start with a shock treatment with steam followed by flushing with cold water to break hard
deposit layers, which will help the cleaning with Careclean Coaltar afterwards.
2.) Fill the system with Careclean Coaltar and circulate by means of a pump at max. 50o C for
approximately 8 hours.
3.) Drain and flush with water.
For badly soiled air coolers use the circulation method or spray system.
Careclean Coaltar is used undiluted by means of a pump, spray and drain tank by circulation
through the air cooler. The cleaning temperature should be 50o C, cleaning time approximately 8
hours.
During the cleaning, the system should be closed and the area around must be ventilated well.
Careclean Coaltar is used undiluted in immersion baths for the cleaning of metal components,
which are badly soiled with Coaltar or similar substances. Afterwards, the parts must be well
flushed with water.
During the cleaning, the bath must be closed and the area must be ventilated well.
Properties
Careclean Coaltar is a slightly yellow coloured liquid with characteristic odour, consisting of a
mixture of 1.2 dichlorobenzene, hydrocarbons and non-ionic + cationic detergents.
Suitable for use on most common metals, however, should NOT be used on rubbers (except Viton
rubber) and plastics (except nylon, polypropylene, epoxy coating and polyurethane).
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies
outside our control we cannot accept any liability for the results.
CARECLEAN BUFFER
• Suitable for the removal of traces of lead and iron stains from zinc silicate coated tank
surfaces after transport of leaded gasoline.
• Suitable for the removal of traces of chloride and sulphide.
• Safe buffered pH of 5.5 for application on zinc-silicate coated tank surfaces.
• Gives a good cleaning result with a reduced cleaning time.
Application
The ordinary cleaning method with a synthetic soap takes a lot of time and is insufficient. A mild
complexing acid solution in combination with synthetic soap gives a much better cleaning result.
Careclean Buffer is used as a final cleaning procedure when leaded gasoline must be removed or
when the tank has to be completely chloride or sulphide free, e.g. for shipping pure chemicals.
Directions of use
After the normal cleaning depending on the nature of the last cargo and subsequent rinsing with
water, the cleaning with Careclean Buffer can start. Never dilute with river or seawater. Fill a
tank for 1/100 part with water and add 10% Careclean Buffer at maximum. The solution is
heated by means of heating coils in the tanks. The tanks are washed with a loading pump, after
which the used solution is recycled to the mixing tank. Usually, one solution is used to wash 2 -
3 tanks.
Careclean Buffer is circulated with a limited contact time of 30 - 45 minutes before rinsing at a
temperature not to exceed 45°C.
Of essential importance for passing the chloride test is a final rinse with chloride free, if possible
hot, water.
If necessary, repeat this cleaning procedure.
Properties
Mild acid, yellowish liquid with a characteristic odour. Completely miscible with water. For use
on all common metals, specially developed for cleaning zinc-silicate coatings.
For detailed information on safety and health, please refer to Material Safety Data Sheet and /
or Product label.
The details of our product are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN AIR FRESH
Careclean Air Fresh is a liquid based on perfumed oils in water. It is suitable for eliminating
unpleasant smells in tanks.
Careclean Air Fresh is safe to use on most common metals and coatings.
Application
Careclean Air Fresh is often used if, after the cleaning of tanks a smell of the previous cargo (e.g. fish
oil or terpentine) is perceptible after tankcleaning. It is recommended that the cause of the smell is
determined before applying the product. If the smell is caused by bad cleaning, the tank should be re-
cleaned because application of the product without tankcleaning may cause a surveyor to reject.
Careclean Air Fresh is sprayed in a 1:10 dilution with water. Normally, 1 to 2 liters of product is
sufficient for one 400 m3 tank. Let the product evaporate for a reasonable period. It is also possible
to dose 0.1 - 1% of the product to the last rinsing water after tankcleaning. Before entering the tank
after treatment, it should be thoroughly ventilated.
Properties
Green colored liquid with a specific smell. Not corrosive to most common metals and coatings.
Non-flammable, miscible with water.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN PICKLING LIQUID
Careclean Pickling Liquid is based on nitric acid, hydrofluoric acid and non-ionic surface-active
substances.
The fluid may be used only on austenitic stainless steel as it corrodes other materials.
It removes weld slag, annealing scale, grinding dust and iron parts etc.
Applications
Careclean Pickling Liquid is used mainly for pickling installations and tanks. It may be used in
the following ways:
1. By circulation
2. Spraying
3. In immersion baths
Pretreatment
Before commencing clean and degrease the surfaces to be pickled, this will give the basis for
uniform pickling. Use Careclean ECS Quick Dry to remove felt pen ink marks.
Use Careclean Alkaline for degreasing small metal surfaces. To degrease tanks etc. We advice the
use of a 1-5% solution of Careclean Aquawash in warm water. After pickling rinse thoroughly
with a jet of water.
Circulation method
This method is used mainly for pipe systems. Fill the system with cold undiluted Careclean
Pickling Liquid. Pickling will take 2 to 6 hours depending on the degree of soiling and on the kind
of austenitic steel do not pickle longer than necessary. Drain the system and rinse carefully,
preferably with demineralised water. After rinsing if required passivation should follow
immediately.
For this use Careclean Passivating Liquid.
Note: Before disposing the pickling liquid it should be neutralised with slaked lime.
Immersion bath method
Fill a plastic or plastic lined bath with undiluted Pickling Liquid. Place the articles to be pickled
into the bath and leave them to soak for 1 to 6 hours depending on the degree of soiling and the
kind of austenitic steel.
Remove the articles from the bath and spray them with a powerful water jet. Demineralised water
should preferably be used for this purpose. Passivation should follow immediately after spraying.
Passivation
A protective oxide layer will form on the austenitic stainless steel only if oxidizing conditions are
present. For example during longterm rinsing in oxygen rich water of during storage in the open
air.
In these circumstances the steel automatically passivates. Because this passive layer takes a long
time to develop to the correct thickness we recommend passivating with Careclean Passivating
Liquid, particularly if the stainless steel is exposed to corrosive conditions soon after the pickling
treatment.
Good results are obtained if the object is sprayed/brushed with Careclean Passivating Liquid
immediately after it has been rinsed. Rinse with plenty of water after approx. 5 minutes.
To neutralise the acid and to make the fluorides and heavy metals insoluble the effluent water and
paste should treated with slaked lime to give a pH balance of 8,5-9. After the soluble substances
have settled the uncontaminated water may be drained. Isolate the insoluble contamination and if
possible drain by means of filtration, otherwise mix with sawdust and dispose of as chemical
waste.
Properties
Strong acidic product containing nitric acid and hydrofluoric acid. Fully miscible with water.
Suitable only for use on austenitic stainless steel. Corrosive on all other steels and many other
materials.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN PASSIVATING LIQUID
• Passivating Liquid is based on nitric acid and non-ionic surface active substances.
• The product provides austenitic stainless steel with a protective oxide layer after it has
been pickled. The metal is then passive.
• Passivating Liquid, undiluted, is suitable for use only on austenitic stainless steel.
Application
Passivating Liquid is used mainly for the passivation of pickled installations and tanks.
It can be applied in the following ways:
1. by circulation
2. by spraying
General
A passivating treatment with Marine Care Passivating Liquid can only take place if the steel has
been pickled previously (i.e. treated with Careclean Pickling Liquid or Careclean Pickling Paste).
Circulation method
This method is applied mainly in pipe systems. Fill the system with undiluted cold Passivating
Liquid. The time taken for treatment is approx. 2 hours. Drain the system and rinse thoroughly
with demineralized water. After drying test the passivity of the steel using the Marine Care
Palladium Test Set.
N.B. Before disposing the passivating fluid it should be neutralised. For this use slaked lime.
Spraying
This method is generally used in tanks with a tank washing device which is resistant to our
product Careclean Passivating Liquid.
The Passivating Liquid fluid is sprayed undiluted using a spraytime of approx. 15 minutes. After
this rinse thoroughly with plenty of water using, preferably, demineralised. After drying, test the
passivity of the steel with the aid of a Marine Care Palladium Test Set.
Properties
Strong acidic product. Contains nitric acid. Fully miscible with water. Undiluted it is suitable for
use only on austenitic stainless steel. When diluted it is suitable for cleaning aluminium.
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control
we cannot accept any liability for the results.
CARECLEAN PICKLING PASTE
Pickling Paste for austenitic stainless steel.
INTRODUCTION
Careclean Pickling Paste is a colourless paste for austenitic stainless steel. It contains nitric acid and
hydrofluoric acid. It contains neither hydrochloric acid nor chlorides.
APPLICATION
Careclean Pickling Paste is used for the pickling of welded seams and surfaces of austenitic stainless
steel in any kind of construction, included for instance the outside of pipes and tanks. Steels other than
austenitic stainless steel will be corroded by the strong pickling effect of the Careclean Pickling Paste.
Nickel, nickel- and copper-nickel-alloys may also be pickled with the Careclean Pickling Paste.
Special precautions have to be followed to prevent these materials from corrosive attack.
Some of these metals and welding materials have been tested.
Kindly contact Marine Care for further information.
1. Pretreatment
See general information.
2. Pickling
Please read the security instructions before you start pickling.
During storage the paste may become partially liquid.
Mix the Careclean Pickling Paste, using a plastic or wooden spoon, then put it on the
surfaces and welded seams to be treated. Use a resistant brush without metal parts.
If the pickling treatment is protracted, clean the brush frequently, so that the dirt is not
widely spread. On conclusion, clean the brush thoroughly with water and allow it to dry.
The Careclean Pickling Paste is applied at room temperature, until the surface is well
covered; a thicker coating should be applied to the welded seams. 1 Kg. of the paste is
sufficient to treat about 70-150 m. of welded seams (5cm wide) or 4-8m² surface
depending on the quantity and nature of iron oxides to be dissolved.
Allow the pickling agent to act for 15-60 minutes on austenitic stainless steel, 5-20
minutes on nickel, nickel-alloys and copper-nickel-alloys (see Applications).
If the pickling has not been sufficient, then rinse and reapply the paste.
For a temperature change of 10 degrees centrigade up or down from
room temperature, the pickling activity and thus the pickling time changes roughly by a
factor of two. Normally it is sufficient to let the Careclean Pickling Paste act for the given
time without a further mechanical action. As the welding quality has a big influence, further
mechanical aid may become necessary. This may for instance be done by brushing with
brushes made from natural or plastic fibres or from austenitic stainless steel, provided
that the paste is still active.
4. Passivation
See general information.
PROPERTIES
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
PRODUCT DATA SHEETS
- Special Products -
CARECLEAN SEWAGE
* Assists in keeping drains, traps and lines clean and clog free.
* pH neutral and therefore not harmful to the system.
* Used to replace aggressive cleaners.
* Maintains system in optimum operational condition.
Application
Careclean Sewage can be applied by slug dosing or metering directly into the sewage tank
(i.e. Marine Sanitation Device (MSD), Collection, Holding and Transfer system (CHTS) or
other type of holding tank.)
A more convenient method is to apply directly to galley and Sewage facilities (e.g.
commodes, sink, shower, and scuppers) as a pH neutral cleaner to replace harsh acid, caustic
and bleach based products which are all highly harmful to the normal operation of any
biological system:
Careclean Sewage performs within a pH range of 5.5-8.5 and a temperature range 10-44oC.
Extremes of pH and temperature, as well as wide shifts in either parameter over a short
period of time should be avoided.
1. Start up dosage of 1 litre of Careclean Sewage per 1.000 litres of tank capacity should be
added directly to the holding tank and allowed a minimum of 24 hours after this initial
application for the system to become properly activated.
2. Additions should be made daily if used as a tankcleaner in amounts of 0,25 litre per 1.000
litres of additional liquids.
3. When used as a cleaner about 100 ml of product should be applied to each bowl, sink and
drain in the same manner as with any janitorial type cleaner. Note: When used as a cleaner,
Careclean Sewage will achieve the maximum results partly due to eliminating line blockage.
Physical properties
Storage
For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.
The details of our products are given completely free of undertaking. Since their application
lies outside our control we cannot accept any liability for the results.
CARECLEAN ULTRASONIC
Cleaning liquid for use in ultrasonic cleaning baths and cleaning machines
* Suitable for use on all common metals (except zinc and some magnesium alloys)
* Designed for ultrasonic equipment
* Easy to dispose
* Low foaming so can be used in cleaning machines.
INTRODUCTION
The cleaning of heavily contaminated fuel and lubricating oil filters, cylinderheads and aircoolers
often give problems. The use of a cleaning agent only is generally unsatisfactory as only a part of
the deposits will be removed, and in most cases carbon residues and other solid materials will be
left behind. In such cases the use of ultrasonic sound waves in combination with a special cleaning
agent gives good results. The contamination will be removed by the ultrasonic process in the
liquid. The special detergents in the cleaning agent keep the contamination dispersed in the liquid
and the complexing agents will partly dissolve them. Careclean Ultrasonic has been developed for
use in ultrasonic baths for the cleaning of all materials except zinc, galvanised parts and/or
magnesium alloy.
APPLICATION
Marine Care design build and commission the "Caretech" ultrasonic cleaning bath systems.
Cleaning Machines
Careclean Ultrasonic is, depending on the nature and degree of contamination, applied in approx.
4% solution in cleaning machines. The contaminated objects must be placed in the machine and
cleaned for 30-60 min. at a temperature of 80 - 90° C. Finally rinse with water.
PROPERTIES
Careclean Ultrasonic is a low foaming mild alkaline liquid. It can be used on all common metals
except zinc, galvanised materials and some magnesium alloys. We advise to test lightmetal alloys
(aluminium/magnesium alloys etc.) i.e. pistons, turboblower parts etc. in advance
for 5-10 minutes. Suitable for use on synthetic materials, rubber and cured lacquers.
Colour : yellowish
Specific gravity (20°C) : 1.19
Flash point PM CC : none
pH (1% solution) : approx. 11,5
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARECLEAN HAND
Rub a little Careclean Hand into dry, dirty hands until the grease and dirt dissolves.
Rinse off with hot or cold water.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and / or
Product label.
The details of our product are given completely free of undertaking. Since their application lies outside our control we
cannot accept any liability for the results.
CARETREAT BACTERIA
A microbiological control agent for use in water, lube oil and fuel oil systems
Application
Caretreat Bacteria is used in cooling water systems and oil storage facilities which have
problems due to bacteria colonization and/or algae in the oil/water interface.
Caretreat Bacteria is ideally suited to the sterilization of Marine Diesel Engine Cooling Water
Systems which have bacteria and/or algae infection.
Diesel Cooling Systems have been prone to this, due to the common occurrence of lubricating
and/or fuel oil mixing with cooling water. This gives an oil/water phase ideal for bacteria to
colonize rapidly. Water containing bacteria leaks into the lube oil system due to faulty glands,
joints and seals or during routine maintenance.
Small amounts of infested water/oil sludges in the storage and circulatory parts of the lube oil
system can quickly lead to major failure of bearing surfaces due to acidic conditions and
degradation of the oils lubricating properties.
If it is above 105/ml, there is a good chance that colonization has taken place throughout the
fuel. In that case, treat at 700 - 1000 ml of Caretreat Bacteria to each m3 of fuel.
NOTE: These basic instructions are intended to give a reasonable guide to the actions required.
* Please contact Marine Care for more details and specific recommendations.
Properties
In accordance with the latest E.E.C. Council directives this product is not subject to any
official recommendation.
A general purpose dispersant for effective removal of mud and silt from ballast tanks,
pipe line systems, open and closed cooling water circuits.
Both dosage recommendations should be considered as the minimum for full effectivenes.
Carefloc should be added via the tank covers, avoiding dispersion problems when dosed via
vents or sounding tubes. If the latter is unavoidable, ensure that plenty of water is added
directly after, to aid mixing.
Note: If “on load” cleaning of specific coolers is required, inject 1 ltr. Carefloc to 10 m3
cooler throughput upstream of the unit for 1 hour.
General hints
A. Prolonged contact of Carefloc with sludge reduces its effective floculation. This should
be considered in ballast tanks which are not continuously being discharged. Sludge
should be removed within seven days maximum.
B. Above 60° C the effect of Carefloc is reduced and, if necessary, dosage rates must be
increased.
C. Carefloc will function over the full pH range, however, it is more effective in alkaline
conditions.
D. Do not use less than 1 ltr. of Carefloc to 20 m3 water.
Injection Equipment
Marine Care has a range of pump and tank units suitable for the injection of Carefloc.
Properties
For detailed information on safety and health, please refer to Material Safety Data Sheet and
/ or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
CARECLEAN HIGH PRESSURE
Application
Careclean High Pressure is mainly used for general cleaning of engine spaces, cleaning of
outside paintwork, cargo holds and tanks.
For use in high pressure machines generally use a 10% solution of Careclean High Pressure
mixed with water in a dosing tank (with pre-washing a 5% solution is sufficient). Adjust the
dosage to such that at the spray nozzle of the high pressure machine a 0.1 – 0.5% solution is
reached. Recommended cleaning temperature is 20 to 80°C. With persistent dirt it is
recommended to spray the product pure or diluted with water to a 10% solution on the object
to be cleaned. After a soaking time of 5 – 10 minutes spray clean water under high pressure.
Properties
Alkaline fluid. Good in hard water. Suitable for use on synthetic material, rubber, hardened
enamel and most metals. It is less suitable for use on aluminum, tin, zinc, galvanized material
and on zinc silicate coatings. Colourless and non-flammable.
For detailed information on safety and health, please refer to Material Safety Data Sheet
and / or Product label.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
PRODUCT DATA SHEETS
- Test Kit´s -
TEST SET - P-ALKALINITY - Product Code 11901
CARETREAT 3 BOILER
3. Add the contents of one Phenolphthalein indicator Powder Pillow and swirl to mix.
4. A pink colour will appear. (If the water remains colourless the P-Alkalinity is zero)
5. Add the Sulfuric Acid Standard Solution drop by drop to the contents of the mixing
bottle, swirling the mixing bottle constantly. Count the drop until the test solution
becomes colourless. (One pipette filled to the 1.0 ml mark equals 15 drops.)
Dosing Table
0 0 0 0.8
3 50 1 0.6
6 100 2 0.4
9 150 3 0.2
12 200 4 0.0
Notes:
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
TEST SET – CHLORIDE - PRODUCT CODE 11902
1. Fill the plastic measuring tube with the water to be tested. Pour the contents of the tube
into the mixing bottle.
3. Add the contents of one Chloride 2 Indicator Powder Pillow swirl to mix.
4. Add the Silver Nitrate Solution drop by drop to the contents of the mixing bottle,
swirling the mixing bottle constantly.
Count the drops until the test solution changes from yellow to red-brown in colour.
(One pipette filled to the 1.0 ml equals 15 drops).
0-15 bar 15-30 bar 30-40 bar 40-60 bar 60-80 bar
200 150 100 50 30
Adjust the Chloride-level by means of blow down and addition of distilled water. The
tons/24h blow down can be calculated using the following equation: Blow down
(ton/24h)=pcm Cl in make up feed X water added (ton/24h)
Notes:
- Instead of ppm Cl, the Chloride-level is sometimes express ppm NaCl (sodium chloride)
- maximum chloride level for cooling water is 100 ppm Cl. Adjust or condensate (free
of Hydrazine, rust) water.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
TEST SET - NITRITE - PRODUCT CODE 11903
CARETREAT 2 DIESEL
1. Thoroughly rinse the marked plastic dropper with the sample to be tested. Then fill
the dropper to the 0.5 ml mark with the sample and discharge it into the colour
viewing tube.
2. Fill this tube to the upper mark (= 10 ml) with demineralized (or battery) water.
Stopper and invert to mix.
3. Divide the diluted sample equally between the colour viewing tubes (each should be
filled to the 5 ml mark).
Add the contents of one Nitriver 2 Nitrite Reagent Powder Pillow to one of the
tubes. Stopper and shake to mix. If Nitrite is present a greenish-brown colour will
develop.(*)
Allow 10 minutes for full colour development.
4. Place the Nitrite Colour Disc in the Colour Comparator.
5. Place the tube prepared with Nitriver 2 in the right opening of the Colour
Comparator.
6. Place the other tube of diluted sample in the left opening of the comparator.
7. Hold the comparator up to a constant light source and view through the opening of
the comparator. Rotate the disc until a colour match is obtained. Read the scale.
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
Caretreat 2 Diesel
Normal rated engine High rated engine
Notes:
The details of our products are given completely free of undertaking. Since their application lies outside our
control we cannot accept any liability for the results.
COOLING WATER TREATMENT TEST (CARETREAT 2 DIESEL)
NITRITE 1. Completely rinse the dropper to be used, then fill the dropper to the 0.5ml mark * INITIAL DOSAGE: 6 LTR/TON (NORMAL RATED)
with the sample and discharge into color viewing tube.
* LIMIT: 2. Fill the tube to the upper mark (=10ml) with demineralized water. 1. Normal rated engine
3. Divide the diluted sample equally between the color viewing tubes (each) 5ml.
1. NORMAL RATE Add 1Nitriver 2 reagent powder pillow to one of the tubes, and stopper & mix PPM DOSAGE
1200-2000ppm well. If nitrite is present a greenisch/brown color will develop. Allow 10 min. 200 5.3 ltr
2. HIGH RATE for HIGH 4. Place the tube prepared with Nitriver 2 in the right position of comparator, and 400 4.5 ltr
SPEED ENGINE: the other tube place to the left. 600 3.8 ltr
2500-3000ppm Rotating disc of comparator until a color match is obtained. 800 3.0 ltr
1000 2.3 ltr
** SCALE READING x 20 = PPM AMOUNT 1200 1.5 ltr
** PH: 9-10
CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. UP TO 100PPM: SATISFACTORY
Pour the contents of the tube into the mixing bottle.
(Limit: up to 100ppm) 2. Fill the bottle with distilled water up to 15ml Over 100PPM: Partly drain and dose Caretreat 2 Diesel
3. Add 1 Chloride 2 indicator powder pillow and mix well. accordingly.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color
*** TEST KIT 1. TEST SET FOR NITRITE 2. CHLORIDE TEST KIT 3. PH PAPER ***
DIESEL ENGINE COOLING WATER GRAPHIC LOG
Date: M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
M. ENGINE
HT SYS.
LT SYS.
AUX. ENGINE 1
AUX. ENGINE 2
Nitrate Level Main Engine: ** To increase Care 2 level by 100 ppm NO2 add 0,4 Ltr/ M3 Submitted by:
Between 1200 - 2000 PPM NO2
Nitrate Level Aux. Engine: Remarks: Approved by
Between 2500 - 3000 PPM NO2 Ch. Engineer
BOILER WATER TREATMENT TEST (CARETREAT 3 BOILER & CARETREAT 4 CONDENSATE)
P-ALKALINITY 1. Completely fill the plastic measuring tube with boiler water. ** CARETREAT 3 BOILER **
Pour the contents of the tube into the mixing bottle.
* (Limit: 100-200ppm) 2. Fill the bottle with distilled water up to 15ml * Initial dosage: 0.75 ltr/ ton
3. Add 1 phenolphtalein indicator powder pillow to the mixing bottle and mix
4. A pink color will appear (if colorless, P-Alkalinity is zero). * Over 200ppm p-Alkalinity - decrease dosage by 25%
Add drop by drop sulphuric acid standard solution counting the number of drops, * p-Alkalinity level between 100-200ppm - satisfactory.
untill the solutions is colorless. * Below 100ppm p-Alkalinity - increase dosage by 25%
CHLORIDE 1. Completely fill the plastic measuring tube with boiler water. *Up to 200ppm: satisfactory
Pour the contents of the tube into the mixing bottle.
* (Limit: up to 300ppm) 2. Fill the bottle with distilled water up to 15ml * Over 200ppm: blowdown
3. Add 1 Chloride 2 indicator powder pillow and mix well.
4. Add silver nitrate solution drop by drop to the mixing bottle counting the number
of drops, until the solution changes from yellow to red/ brown in color
CONDENSATE PH 1. Take condensate water sample, and immerse pH paper. ** CARETREAT 4 CONDENSATE **
2. Read the pH value..
* (Limit: pH 9-9.5) * Initial dosage: 0.2 ltr/ ton
* 0.4 ltr/ 24 hours - normal daily dosage
*** TEST KIT 1. TEST SET FOR P-ALKALINITY 2. CHLORIDE TEST KIT 3. PH PAPER ***
BOILER WATER GRAPHIC LOG
Date:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
350
300
250 Decrease Dosage 10%
200
150 Ideal
100
50 Increase Dosage 25%
0
CHLORIDES / ppm C1
210
180
150
120
90
60
30
0
CONDENSATE / pH
10.0 Decrease Care 4 Dosage 10%
9.5 Ideal
9.0
8.5 Increase Care 4 Dosage 25%