Booster Regulator/Air Tank

Series VBA/VBAT

Increase factory air pressure by up to 4 times! RoHS


Air-only operation requires no power supply, ARJ
reduces heat generation, and AR425
to 935
Boost pressure
allows easy installation. Heavy
ARX

0.6 MPa AMR


0.3 MPa
Renewed model with Factory line ARM
pressure increase ratio
2 to 4 times (VBA11A) ARP
Booster Regulator + Air Tank
0.3 MPa IR
0.3 MPa

Light
IRV

Compressor VEX
0.3 MPa
Light SRH
SRP
No power supply or wiring needed Easy installation
SRF
There is no need to Simply install the unit
install dedicated in the air line. VCHR
electrical wiring. Requires far less
space than installing
the compressor.
ITV
IC

Low heat generation Air-only operation ITVX


Very little heat is Operation is safe PVQ
generated because because no
VEF
no electricity is electricity is used. VEP
used, and there is
no impact on VER
cylinders, solenoid
valves, etc. VEA
VY1
VBA
VBAT

AP100

Booster Regulator/Series VBA Air Tank/Series VBAT


921
Booster Regulator Series VBA

Improved Doubled
service life that of the conventional model
Reduced
noise
Reduced by 13 dB (A)
compared with the conventional model
• Floating piston structure • Metal noise reduced by a bumper on the impact part
• Grease retaining groove∗ of the switch valve
∗ Except VBA10A, 11A • Exhaust noise
Grease reduced by a high-
retaining
groove
noise reduction
silencer
Switching valve

Floating structure Bumper

Improved reliability Anti-condensation

Built-in mesh filter at IN port Integrated air-feeding tube with the


• Prevents operation failure due to foreign matter. main tube Cylinder tube
• Mitigates condensation Tie-rod guide
Mesh filter
caused by cooling during
exhaust expansion.
Air-feeding tube

VBA20A

VBA40A

Elbow silencer added∗ (Option) 1/8" gauge ports

Space saving when installed has • Allows use of standard fittings for remote
pressure monitoring, etc.
been realized. ∗ Gauge ports changed from 1/16" to 1/8" (VBA1A, 2A)
Elbow silencer
∗ Except VBA2A, 4A

Gauge port
VBA10A

Air-operated type Max. operating pressure 1.6 MPa Fourfold pressure


increase type

VBA22A

VBA11A
VBA43A

VBA42A
922
P.924
Pressure increase ratio Twice 2 to 4 times
Handle-operated type Air-operated type Handle-operated type
Operation (Direct operation) (Remote operation) (Direct operation)
Set pressure
range
0.2 to 1.0 MPa 0.2 to 1.6 MPa 0.2 to 1.0 MPa 0.2 to 2.0 MPa
Body size (2.0 MPa)
ARJ
VBA10A-02 VBA11A-02
(0.2 to 2.0 MPa) AR425
to 935

ARX
1/4"
AMR
ARM
ARP
VBA20A-03 VBA22A-03 IR
IRV
3/8" VEX
SRH
SRP

VBA40A-04 VBA43A-04 VBA42A-04 SRF


(0.2 to 1.6 MPa)
VCHR
ITV
1/2"
IC
ITVX
PVQ
VEF
Air Tank Series VBAT P.935 VEP

VER
Perfect fit with a booster regulator
This is an air tank to which a booster regulator can be connected VEA
compactly. It can be used alone as a tank. The pressure vessel law is
different from country to country, so as an air tank suitable to a VY1
country needs to be confirmed.
VBA
VBAT
Extensive product lineup
To meet a variety of usage environment and pressure specifications, AP100
models are available in two materials, stainless steel 304 and carbon
steel (SS400), and in four sizes ranging from 5 liters to 38 liters.

Model VBAT05A VBAT10A VBAT20A VBAT38A


Tank capacity (L) 5 10 20 38
Max. operating pressure (MPa) 2.0 1.0
Material Carbon steel

Model VBAT05S VBAT10S VBAT20S VBAT38S


Tank capacity (L) 5 10 20 38 Caution
Max. operating pressure (MPa) 2.0 When used as a single unit (not connected with a booster regulator) and
Material Stainless steel pressurized at over 1 MPa at normal temperatures, the air tank falls
under the scope of the “High Pressure Gas Safety Act” in Japan.
923
Booster Regulator

Series VBA RoHS

Made to Order
How to Order (For details, refer to page 934.)

VBA 40A 04
Body size Semi-standard
10A 1/4", Handle-operated type Symbol Semi-standard
20A 3/8", Handle-operated type Nil Standard product
40A 1/2", Handle-operated type Pressure increase Pressure unit on the product name
Z Note) label and pressure gauge: psi
22A 3/8", Air-operated type ratio: Twice
Note) Thread type: NPT, NPTF
42A 1/2", Air-operated type
Under the new measurement law, the pressure
43A 1/2", Max. operating pressure 1.6 MPa unit of “psi” on the pressure gauges cannot be
Pressure increase used in Japan.
11A 1/4", Handle-operated type
ratio: 2 to 4 times Option
Symbol Option
Thread type Note)
Nil None
Symbol Thread type
Nil
G Pressure gauge
Symbol Rc
N Silencer
F G
S High-noise reduction silencer Note)
N NPT
GN Pressure gauge, Silencer
T NPTF
GS Pressure gauge, High-noise reduction silencer Note)
Note) Thread types apply to the IN, OUT,
and EXH ports of the VBA1A and to LN Elbow silencer Note)
the IN, OUT, EXH, and gauge ports of LS Elbow high-noise reduction silencer Note)
the VBA2A and VBA4A. GLN Pressure gauge, Elbow silencer Note)
The gauge ports of the VBA1A are GLS Pressure gauge, Elbow high-noise reduction silencer Note)
Rc thread type regardless of the
thread type indication. Note) Refer to “Combination of Thread Type and Options.”

Port size Pressure Pressure


gauge gauge
VBA10A-02 Symbol Port size Applicable series
VBA11A-02 02 1/4 VBA1A
03 3/8 VBA2A
04 1/2 VBA4A

Silencer Elbow silencer

Combination of Thread Type and Options


VBA20A-03 Thread Option Semi-standard
Body size
type Nil G N S GN GS LN LS GLN GLS Nil -Z
Nil            —
10A F            —
11A N    —  —  —  —  
VBA22A-03
T    —  —  —  —  
Nil        —
20A F        —
22A N        
T        
Nil        —
40A
F        —
42A
N        
43A
T        
VBA40A-04 Air Tank Compatibility Chart
Booster
regulator
VBA1A VBA2A VBA4A
Air tank
VBAT05A
 — —
VBAT05S
VBAT10A
  —
VBAT10S
VBAT20A —  
VBA42A-04 VBAT20S
VBA43A-04 VBAT38A —  
VBAT38S

924
Booster Regulator Series VBA

Standard Specifications
Model VBA10A-02 VBA20A-03 VBA40A-04 VBA22A-03 VBA42A-04 VBA43A-04 VBA11A-02
Fluid Compressed air
Pressure increase ratio Twice 2 to 4 times
Handle-operated with
Pressure adjustment mechanism Handle-operated with relief mechanism Note 1) Air-operated
relief mechanism Note 1)
Max. flow rate Note 2) (L/min (ANR)) 230 1000 1900 1000 1900 1600 70 ARJ
Set pressure range (MPa) 0.2 to 2.0 0.2 to 1.0 0.2 to 1.0 0.2 to 1.6 0.2 to 2.0
Supply pressure range (MPa) 0.1 to 1.0
AR425
to 935
Proof pressure (MPa) 3 1.5 2.4 3
Port size (Rc)
1/4 3/8 1/2 3/8 1/2 1/4
ARX
(IN/OUT/EXH: 3 locations)
Pressure gauge port size (Rc)
1/8 AMR
(IN/OUT: 2 locations)
Ambient and fluid temperature (°C) 2 to 50 (No freezing) ARM
Installation Horizontal
Lubrication Grease (Non-lube) ARP
Weight (kg) 0.84 3.9 8.6 3.9 8.6 8.6 0.89
Note 1) If the OUT pressure is higher than the set pressure by the handle, excess pressure is exhausted from the back of the handle. IR
Note 2) Flow rate at IN= OUT= 0.5 MPa. The pressure varies depending on the operating conditions. Refer to “Flow-rate Characteristics” on pages 926 and 927.

Options/Part No. IRV


Pressure Gauge, Silencer (When thread type is Rc or G.) VEX
Model VBA10A-02 VBA20A-03 VBA40A-04 VBA22A-03 VBA42A-04 VBA43A-04 VBA11A-02
Description VBA10A-F02 VBA20A-F03 VBA40A-F04 VBA22A-F03 VBA42A-F04 VBA43A-F04 VBA11A-F02 SRH
Pressure gauge G G27-20-01 G36-10-01 KT-VBA22A-7 G36-10-01 G27-20-01 G27-20-01
Silencer N AN20-02 AN30-03 AN40-04 AN30-03 AN40-04 AN40-04 AN20-02 SRP
High-noise reduction silencer S ANA1-02 ANA1-03 ANA1-04 ANA1-03 ANA1-04 ANA1-04 ANA1-02
Elbow for silencer L KT-VBA10A-18 — — — — — KT-VBA10A-18 SRF
Note 1) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories.
Note 2) KT-VBA22A-7 is a pressure gauge with fitting. (Please order two units when using with IN and OUT.)
VCHR
Pressure Gauge, Silencer (When thread type is NPT or NPTF.)
Model VBA10A-N02∗ VBA20A-N03∗ VBA40A-N04∗ VBA22A-N03∗ VBA42A-N04∗ VBA43A-N04∗ VBA11A-N02∗ ITV
VBA10A-T02∗ VBA20A-T03∗ VBA40A-T04∗ VBA22A-T03∗ VBA42A-T04∗ VBA43A-T04∗ VBA11A-T02∗
Description ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” ∗: when “-Z” IC
Pressure gauge ∗: when Nil G27-20-01 G36-10-N01 KT-VBA22A-7N G36-10-N01 G27-20-N01 G27-20-01
G
Pressure gauge ∗: when “-Z” Note 4)
Silencer N
G27-P20-01
AN20-N02
G36-P10-N01
AN30-N03 AN40-N04
KT-VBA22A-8N
AN30-N03
G36-P10-N01
AN40-N04
G27-P20-N01
AN40-N04
G27-P20-01
AN20-N02
ITVX
High-noise reduction silencer S — ANA1-N03 ANA1-N04 ANA1-N03 ANA1-N04 ANA1-N04 —
Elbow for silencer L KT-VBA10A-18N — — — — — KT-VBA10A-18N PVQ
Note 1) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. VEF
Note 2) KT-VBA22A-7N, KT-VBA22A-8N are pressure gauges with fittings. (Please order two units when using with IN and OUT.) VEP
Note 3) Under the new measurement law, the pressure unit of “psi” on the pressure gauges cannot be used in Japan.
Note 4) Pressure unit on the pressure gauge: psi
VER
Related Products/Part No. Design
VEA
Mist Separator, Exhaust Cleaner Caution
Model
For VBA10A-02 For VBA20A-03
For VBA40A-04 1. System configuration VY1
For VBA42A-04 • The IN port of the booster regulator has metallic mesh to prevent
For VBA11A-02 For VBA22A-03 VBA
Description For VBA43A-04 dust from entering the booster regulator. However, it cannot
remove dust continuously or separate drainage. Make sure to
VBAT
Mist separator AM250C-02 AM450C-04, 06 AM550C-06, 10
install a mist separator (AM series) on the inlet side of the
Exhaust cleaner AMC310-03 AMC510-06 AMC610-10
Note) Refer to page 935 for air tanks, page 201 for mist separators and Best
booster regulator. AP100
Pneumatics No.6 for exhaust cleaners. • The booster regulator has a sliding part inside, and it generates
Refer to the separate operation manual for the connection method. dust. Also, install an air purification device such as an air filter or
a mist separator on the outlet side as necessary.
• Connect a lubricator to the outlet side, because the accumulated
oil in the booster regulator may result in a malfunction.
2. Exhaust air measures
• Provide a dedicated pipe to release the exhaust air from each
booster regulator. If exhaust air is converged into a pipe, the
back pressure that is created could cause improper operation.
• Depending on the necessity, install a silencer or an exhaust
cleaner on the exhaust port of the booster regulator to reduce
the exhaust noise.
3. Maintenance space
• Allow the sufficient space for maintenance and inspection.
925
Series VBA

VBA10A VBA20A, 22A VBA40A, 42A

Flow-rate Characteristics Flow-rate Characteristics Flow-rate Characteristics


2 1.0 1.0
P1
=1
.0
MP 0.8 0.8
a
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


1.5
P1 P1 = 0.5 MPa
=0
.75
MP 0.6 0.6
a
1 P1
=0 P1 = 0.5 MPa
P1 .5 0.4 0.4
=0 MP
.4 a P1 = 0.4 MPa
P1 MP P1 = P2
=0 a P1 = 0.4 MPa
0.5 .3 P1 = 0.3 MPa
MP P1 = 0.3 MPa
a 0.2 0.2

0 100 200 300 400 0 200 400 600 800 1000 1200 0 500 1000 1500 2000
Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR))

Pressure Inlet pressure: 0.7 MPa


(Representative Pressure Inlet pressure: 0.7 MPa
(Representative Pressure Inlet pressure: 0.7 MPa
(Representative
Characteristics Outlet pressure: 1.0 MPa
Flow rate: 20 L/min (ANR)
value) Characteristics Outlet pressure: 1.0 MPa
Flow rate: 20 L/min (ANR)
value) Characteristics Outlet pressure: 1.0 MPa
Flow rate: 20 L/min (ANR)
value)

1.1 1.04 1.04

1.05 Set point


1.02 Set point 1.02 Set point
Outlet pressure (MPa)

Outlet pressure (MPa)

Outlet pressure (MPa)


1.0
1.0 1.0
0.95
0.98 0.98
0.9
0.96 0.96
0.85

0.8 0.94 0.94

0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa)

Charge Characteristics Charge Characteristics Charge Characteristics


60 12 5
11
50 10
Charge time per 10 L t (s)

Charge time per 10 L t (s)

Charge time per 10 L t (s)

4
9
40 8
7 3
30 6
5 2
20 4
3
1
10 2
1
0 0 0
1.0 1.2 1.4 1.6 1.8 2.0 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0
Pressure increase ratio P2/P1 Pressure increase ratio P2/P1 Pressure increase ratio P2/P1

VBA10A VBA20A, 22A VBA40A, 42A


 The time required to charge pressure in the  The time required to charge pressure in the  The time required to charge pressure in the
tank from 0.7 MPa to 0.95 MPa at 0.5 MPa tank from 0.8 MPa to 1.0 MPa at 0.5 MPa tank from 0.8 MPa to 1.0 MPa at 0.5 MPa
supply pressure: supply pressure: supply pressure:
P2 0.7 P2 0.95 P2 0.8 P2 1.0 P2 0.8 P2 1.0
= = 1.4 = = 1.9 = = 1.6 = = 2.0 = = 1.6 = = 2.0
P1 0.5 P1 0.5 P1 0.5 P1 0.5 P1 0.5 P1 0.5
With the pressure increase ratio from 1.4 to 1.9, With the pressure increase ratio from 1.6 to 2.0, With the pressure increase ratio from 1.6 to 2.0,
the charge time of 23 – 6 = 17 sec. (t) is given the charge time of 11.5 – 3.8 = 7.7 sec. (t) is the charge time of 3.5 – 1.1 = 2.4 sec. (t) is given
by the graph. Then, the charge time (T) for a given by the graph. Then, the charge time (T) by the graph. Then, the charge time (T) for a
10 L tank: for a 100 L tank: 100 L tank:
V 10 V 100 V 100
T=tx = 17 x = 17 (s). T=tx = 7.7 x = 77 (s). T=tx = 2.4 x = 24 (s).
10 10 10 10 10 10

926
Booster Regulator Series VBA

VBA43A VBA11A Pulsation/Pulsation is decreased with a tank.


If the outlet capacity is undersized, pulsation may
occur.
Flow-rate Characteristics Flow-rate Characteristics

1.6
2 VBAT05A
0.1
1.4
ARJ
Outlet pressure (MPa)

Outlet pressure (MPa)

P1
1.2 P1

Max. pulsation range (MPa)


=0 0.08 AR425

=
1.
P1 .8

P1

0
=0
1 P1 MP to 935

M
.7 a

Pa
0.
P1 =0 MP

75
P1
= .6 a 1
0.8 0. MP 0.06
ARX

M
=0
P1
5

Pa
MP a

P1

.5
=0
0.6 a P1 = P2

MP
=0

.4
P1 = P2

MP
.3

a
0.04
AMR

MP
0.4

a
a
0.2
0.02
VBAT05A ARM
0 500 1000 1500 2000 2500 3000 0 50 100 150
Outlet air flow rate (L/min (ANR)) Outlet air flow rate (L/min (ANR))
0 1 2 3 4 5 ARP
Pressure Inlet pressure: 0.7 MPa
(Representative Pressure Inlet pressure: 0.6 MPa
(Representative Capacity (L)
Characteristics Outlet pressure: 1.0 MPa
Flow rate: 20 L/min (ANR)
value) Characteristics Outlet pressure: 2.0 MPa
Flow rate: 10 L/min (ANR)
value)
IR
VBAT
1.08 2.1

1.06
Set point IRV
2.05
VBA1A
VEX
Outlet pressure (MPa)

Outlet pressure (MPa)

1.04
Set point 2.0
1.02 VBAT10A, 20A, 38A
1.0
1.95 SRH
0.1
1.9
0.98 SRP
Max. pulsation range (MPa)
1.85 0.08
0.96

1.8
SRF
0.94
0.06

0 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.4 0.5 0.6 0.7 0.8 0.9 1 VBAT10A VCHR
Inlet pressure (MPa) Inlet pressure (MPa) 0.04
ITV
Charge Characteristics Charge Characteristics 0.02
VBAT20A
VBAT38A IC
5 400
0 10 20 30 38 40
ITVX
Capacity (L)
Charge time per 10 L t (s)

Charge time per 10 L t (s)

4
300
VBAT PVQ
3
VEF
200 VEP
VBA2A
2

Conditions:
VBA4A
VER
100
1 Inlet pressure: 0.5 MPa
Outlet set pressure: 1 MPa
Flow rate: Between 0 and max. flow rate
VEA
0 0
1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 1.0 2.0 3.0 4.0
• Performance of air tank VY1
Pressure increase ratio P2/P1 Pressure increase ratio P2/P1 • Alleviates the pulsation generated on the
outlet side. VBA
VBA43A VBA11A VBAT
• When air consumption exceeds air supply
 The time required to charge pressure in the  The time required to charge pressure in the during intermittent operation, required air
tank from 0.8 MPa to 1.0 MPa at 0.5 MPa
supply pressure:
tank from 1.0 MPa to 1.5 MPa at 0.5 MPa
supply pressure:
will be accumulated in the tank for use. AP100
This does not apply for continuous
P2 0.8 P2 1.0 P2 1.0 P2 1.5 operation.
= = 1.6 = = 2.0 = = 2.0 = = 3.0
P1 0.5 P1 0.5 P1 0.5 P1 0.5
With the pressure increase ratio from 1.6 to 2.0, With the pressure increase ratio from 2.0 to 3.0,
the charge time of 4.5 – 1.3 = 3.2 sec. (t) is the charge time of 147 – 58 = 89 sec. (t) is
given by the graph. Then, the charge time (T) given by the graph. Then, the charge time (T)
for a 100 L tank: for a 10 L tank:
V 100 V 10
T=tx = 3.2 x = 32 (s). T=tx = 89 x = 89 (s).
10 10 10 10

927
Series VBA

Sizing ( Sizing can be achieved with the SMC Pneumatic System Energy Saving Program Ver. 3.1
which can be downloaded from the SMC website: http://www.smcworld.com )
Tc Ts

Stroke
P1 P3 P2

L
øD Upper limit of pressure inside the tank P3
Necessary supply

Pressure
pressure to cylinder P2
Lower limit of pressure inside the tank P2
Inlet pressure P1

START Time
Necessary conditions: Example Other conditions:
D [mm]: Cylinder bore size 100 Q [L/min (ANR)]: Required air flow rate
L [mm]: Cylinder stroke 100 Qb [L/min (ANR)]: Outlet air flow rate of booster regulator
W [mm/s]: Cylinder operating speed Tc [s]: Cylinder operating time
200
C [pc.]: Number of cylinders K: Cylinder double-acting: 2, single-acting: 1
1
Tc [s]: Cylinder operating time P3 [MPa] Note 2): Tank charge pressure
Provide requisite Ts [s]: Cylinder stop time 0.5 T1 [s]: Time to charge (Time to charge to P2)
conditions for P1 [MPa]: Inlet pressure 30 T2 [s]: Time to charge (Time to charge to P3)
selection. P2 [MPa] Note 1): Necessary supply 0.5 T [s]: Time to charge (Time to charge from P2 to P3)
pressure to cylinder 0.8 Z: Number of booster regulators
Note 1) P2 is the necessary supply pressure to a cylinder, and set the pressure below the lower limit of pressure inside the tank
with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration.
Note 2) P3 is the output pressure of the booster regulator, which is also the upper limit of charge pressure to the tank.

π x D2 x W (P2 + 0.101)
Caution
Q [L/min (ANR)] = x x 60 x C
4 x 106 0.101 • Use the VBA11A (pressure increase ratio 4) with pressure
Calculate required increase ratio 2 to 4. Usage of pressure increase ratio below 2
air flow rate Q. π x 1002 x 200 (0.8 + 0.101) is preferred for the VBA10A (pressure increase ratio 2).
Q= x x 60 x 1 = 841 [L/min (ANR)]
4 x 106 0.101 A stable operation and increased life expectancy will result.
• Inlet supply pressure volume is {approximately twice (pressure
increase ratio 2), approx. 4 times (pressure increase ratio 4)}
Select booster regulator VBA2A: Qb = 600 [L/min (ANR)] the volume of the outlet side. Booster regulator requires the
size from flow-rate VBA4A: Qb = 1050 [L/min (ANR)] inlet side volume which is the sum of the flow volume running
characteristics table. Refer to “Flow-rate Characteristics” on pages 926 and 927. into the outlet side and the volume exhausted from E port (for
driving), because air is the power source.

NO: Need no tank The VBA4A can supply necessary pressure.


Avoid
pulsation. NO
Judgement of
flow rate (Max. 0.05
MPa)

YES The VBA2A cannot obtain necessary pressure. YES

V [L] =
(Q – Qb/2) x (Tc x K/60) Select the tank
(P3 – P2) x 9.9 from table below.
Obtain the tank
capacity V.
(841 – 600/2) x (0.5 x 2/60)
V= = 4.6 [L] Tank model Internal capacity Applicable combination model
(1.0 – 0.8) x 9.9
VBAT05 5L VBA1A — —
VBAT10 10 L VBA1A VBA2A —
Select the tank Select the VBAT10, which can be
capacity over V. directly connected to the VBA2A. VBAT20 20 L — VBA2A VBA4A
VBAT38 38 L — VBA2A VBA4A

Refer to “Charge Characteristics” on pages 926 and 927.


Calculate time T from
charge characteristics T [s] = ( V ) x T2 – T1
10 Z
table.

4.6 11.5 – 3.8


T=( )x = 3.5 [s]
10 1

Extend
Judgement NO stop time Ts NO Increase number of
of charge time up to charge time booster regulators (Z)
T ≤ Ts T or more. to decrease T.

YES YES YES

When running continuously for longer periods of time, confirm the life expectancy.
When the life expectancy is shorter than required, select a larger sized booster regulator.
END
928
Booster Regulator Series VBA

Working Principle

The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and
the switching valve. Then, the air pressure from drive chamber B and booster chamber A are applied to the piston, boosting the air in booster
chamber B. As the piston travels, the boosted air is pushed via the check valve to the OUT side. When the piston reaches to the end, the piston
causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively.
Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster
chamber A and sends it to the OUT side. The process described above is repeated to continuously supply highly pressurized air from the IN to
the OUT side. The governor establishes the outlet pressure by handle operation and pressure adjustment in the drive chamber by feeding back ARJ
the outlet pressure.
AR425
Air-operated type to 935
VBA10A, 20A, 40A, 43A Pilot pressure VBA11A
Drive Governor Governor Drive ARX
chamber A chamber A
Booster Drive
chamber A IN (Inlet) IN (Inlet)
chamber B AMR
Drive chamber B
VBA22A, 42A ARM
Piston rod Piston rod
ARP
Booster
chamber A
Piston
Piston
IR
IRV
Check valve Booster chamber B Booster Check valve
chamber B
Switching valve E OUT (Outlet) OUT (Outlet) E Switching valve
VEX
Circuit Example
SRH
• When only some of the machines in the plant require high-pressure • When the actuator output is insufficient but space limitations prohibit
air, booster regulators can be installed for only the equipment that switching to a larger cylinder diameter, a booster regulator can be SRP
requires it. This allows the overall system to use low-pressure air used to increase the pressure. This makes it possible to boost the
while accommodating machines requiring high-pressure air. output without replacing the actuator.
General line (low pressure) Locations requiring high pressure • When a certain level of output is required but the cylinder size must SRF
be kept small so that the driver remains compact.
VCHR
Plant line (source pressure)

VBA ITV
ø80
VBA (Two-stage ø100
pressure boost)
IC
OUT 0.8 MPa
VBA E ITVX
0.5 MPa
IN 0.5 MPa PVQ
Operating pressure: Operating pressure:
0.5 MPa 0.8 MPa
VEF
VBA Equivalent
VEP
Bore size: ø100 output Bore size: ø80
Output ≈ 3850 N Output ≈ 4000 N
• When charging a tank or the like from a source at atmospheric VER
pressure, a circuit with a check valve can be used to reduce the
charge time by allowing air to pass through the check valve up to • When only one side of the cylinder is used for work, booster VEA
the inlet pressure. regulators can be installed only on the lines that require them to
reduce the overall air consumption volume.
VY1
P1
P2 VBA
VBAT

AP100
Initially, inlet pressure (P1) passes through the check valve, fills P2,
and results in P1 = P2.

Shortening time
Outlet pressure (MPa)

P2

P1

Without check
valve by-pass

0 Time t (S)

929
Series VBA

Design Mounting

Warning Caution
1. Warning concerning abnormal outlet pressure 1. Transporting
• If there is a likelihood of causing an outlet pressure drop • When transporting this product, hold it lengthwise with both
due to unforeseen circumstances such as equipment hands. Never hold it by the black handle that protrudes from
malfunction, thus leading to a major problem, take safety the center because the handle could become detached
measures on the system side. from the body, causing the body to fall and leading to injury.
• Because the outlet pressure could exceed its set range if
there is a large fluctuation in the inlet pressure, leading to 2. Installation
unexpected accidents, take safety measures against abnor- • Install this product so that the silver-colored tie-rods and
mal pressures. cover are placed horizontally. If mounted vertically, it may
• Operate the equipment within its maximum operating result in a malfunction.
pressure and set pressure range. • Because the piston cycle vibration is transferred, use the
following mounting bolts (VBA1: M5; VBA2, 4: M10) and
2. Residual pressure measures tighten them with the specified torque (VBA1: 3 N·m; VBA2,
• Connect a 3-port valve to the OUT side of the booster 4: 24 N·m).
regulator if the residual pressure must be released quickly • If the transmission of vibration is not preferred, insert an
from the outlet pressure side for maintenance, etc. (Refer to isolating rubber material before installation.
the diagram below.) The residual outlet pressure side • Mount the pressure gauge with a torque of 7 to 9 N·m.
cannot be released even if the 3-port valve is connected to
the IN side because the check valve in the booster regulator
will activate. Piping

Caution
1. Flushing
• Use an air blower to flush the piping to thoroughly remove
any cutting chips, cutting oil, or debris from the piping
• After operation is finished, release the supply pressure at
inside, before connecting them. If they enter the inside of
the inlet. This stops the booster regulator from moving
the booster regulator, they could cause the booster regula-
needlessly and prevents operating malfunctions.
tor to malfunction or its durability could be affected.
2. Piping size
• To bring the booster regulator’s ability into full play, make
sure to match the piping size to the port size.

Air Supply
Selection
Caution
Caution 1. Quality of air source
1. Check the specifications. • Connect a mist separator to the inlet side near the booster
• Consider the operating conditions and operate this product regulator. If the quality of the compressed air is not
within the specification range that is described in this thoroughly controlled, the booster regulator could malfunc-
catalog. tion (without being able to boost) or its durability could be
affected.
2. Selection • If dry air (atmospheric pressure dew point: –23°C or less) is
• Based on the conditions (such as pressure, flow rate, takt
used, the life expectancy may be shortened because dry air
time) required for the outlet side of the booster regulator,
select the size of the booster regulator in accordance with will accelerate evaporation of grease inside.
the selection procedures described in this catalog or model
selection program.
• Use the VBA11A (pressure increase ratio 4) with pressure Operating Environment
increase ratio 2 to 4. Usage of pressure increase ratio
below 2 is preferred for the VBA10A (pressure increase
ratio 2). A stable operation and increased life expectancy
Caution
will result. 1. Installation location
• Inlet supply pressure volume is {approximately twice • Do not install this product in an area that is exposed to
(pressure increase ratio 2), approx. 4 times (pressure rainwater or direct sunlight.
increase ratio 4)} the volume of the outlet side. Booster • Do not install in locations influenced by vibrations. If it must
regulator requires the inlet side volume which is the sum of be used in such an area due to unavoidable circumstances,
the flow volume running into the outlet side and the volume please contact SMC beforehand.
exhausted from E port (for driving), because air is the power
source.
• When running continuously for longer periods of time,
confirm the life expectancy. The life expectancy of a booster
regulator is dependent upon the operational cycle. Thus,
when used for driving cylinders, etc. in the outlet side, life
expectancy will be reduced.
• Make sure the outlet pressure is set 0.1 MPa or higher than
the inlet pressure. A pressure difference below 0.1 MPa
makes the operation unstable and may result in a malfunc-
tion.
930
Booster Regulator Series VBA

Handling

Caution
1. Setting the pressure on the handle-operated type 3. Draining
• If air is supplied to the product in the shipped state, the air • If this product is used with a large amount of drainage
will be released. accumulated in the filter, mist separator or tank, the
Set the pressure by quickly pulling up on the governor drainage could flow out, leading to equipment malfunction. ARJ
handle, releasing the lock, and rotating the handle in the Therefore, drain the system once a day. If it is equipped
AR425
direction of the arrow (+). with an auto drain, check its operation once a day. to 935
• There is an upper and lower limit for the handle rotation. If
4. Exhaust
over-rotating the handle even after reaching to the limit, the
internal parts may be damaged. If the handle suddenly feels
• Exhausting time from E port may be longer for a booster ARX
regulator which is set to switch in longer hour intervals. This
heavy while being turned, stop turning the handle.
• Once the setting is completed, push the handle down and
is not an abnormal phenomenon. AMR
lock it. 5. Maintenance
• To decrease the outlet pressure, after the pressure has • Life expectancy varies depending on the quality of air and ARM
been set, rotate the handle in the direction of the arrow (–). the operating conditions. Signs that the unit is reaching the
The residual air will be released from the area of the end of its service life include the following:
handle, due to the relief construction of the governor. • Constant bleed from under the handle.
ARP
• To reset the pressure, first reduce the pressure so that it is • Air exhaust noise can be heard from the booster regulator
lower than the desired pressure; then, set it to the desired at 10 to 20 second intervals even when there is no air IR
pressure. consumption on the outlet side.
Conduct maintenance earlier than scheduled in such cases. IRV
• When maintenance is required, confirm the model and serial
number of the booster regulator, and please contact SMC
VEX
SMC
Low High
for maintenance kit.
• Conduct maintenance according to the specified mainte-
nance procedure by individuals possessing enough knowl- SRH
2. Setting the pressure on the air-operated type edge and experiences in maintaining pneumatic equipment.
(VBA22A, 42A) • The list of replacement parts and kit number are shown on
page 932, and the figure shows the position of the parts.
SRP
• Connect the outlet pipe of the pilot regulator for the remote
control to the pilot port (P). (Refer to the diagram below.)
• Refer to the graph below for the relationship between the SRF
pilot pressure and outlet pressure.
• The AR20 and AW20 are recommended for the pilot regula- VCHR
tor.
ITV
Pilot regulator
IC
ITVX
P
IN OUT PVQ
VEF
E VEP

• The outlet pressure is twice the pilot pressure. VER


• When the inlet pressure is 0.4 MPa:
Pilot pressure 1 VEA
0.2 MPa to 0.4 MPa 0.9
Outlet pressure
VY1
0.8
Outlet pressure MPa (Q = 0)

0.4 MPa to 0.8 MPa VBA


0.7 VBAT
0.6
AP100
0.5

0.4

0.3

0.2

0.1

0
0.1 0.2 0.3 0.4 0.5
Pilot pressure MPa

931
Series VBA

Construction/Replacement Parts
VBA10A VBA11A

q r e w t u r e w t q

VBA20A, 22A, Air-operated type


VBA40A, 42A, 43A
q
tqyr we

VBA22A, 42A

Replacement Parts/Kit No.


Place an order with the following applicable kit number.
Model VBA10A VBA20A VBA40A VBA22A VBA42A VBA43A VBA11A
Kit no. KT-VBA10A-1 KT-VBA20A-1 KT-VBA40A-1 KT-VBA22A-1 KT-VBA42A-1 KT-VBA43A-1 KT-VBA11A-20

The kit includes the parts from q to u and a grease pack.


Model VBA10A VBA20A VBA40A VBA22A VBA42A VBA43A VBA11A
No.
Description Quantity
1 Piston seal 2 2 large 1 small 2 1 each large and small
2 Governor assembly 1
3 Check valve 4 2
4 Gasket 2
5 Rod seal 1
6 Mounting screw — 8 12 8 12 —
7 Cover C assembly — 1
— Grease pack 1 2 1 2 1
∗ The grease pack has 10 g of grease.
∗ Make sure to refer to the procedure for maintenance.

932
Booster Regulator Series VBA

Dimensions
VBA10A-02 With elbow silencer (Option)
150
Pressure gauge (Option) Elbow silencer (Option)
60
IN side OUT side
gauge port gauge port 7 28 7 28
Rc 1/8 Rc 1/8
Silencer
(Option)
ARJ

113

113
IN port IN port
1/4 1/4 AR425

23

23
OUT port OUT port to 935
1/4 1/4
ARX

27

27
22

22
40 4 x ø5.5 60 EXH port 4 x ø5.5 60
8.5

50 70 1/4 70 AMR
(When silencer installed: 107) (97)
(When high-noise reduction
silencer installed: 126)
EXH port ARM
1/4
VBA11A-02 With elbow silencer (Option)
ARP
150
Pressure gauge (Option)
33 30 Elbow silencer (Option)
IR
IN side OUT side
gauge port gauge port 7 28 7 28
Rc 1/8 Rc 1/8 IRV
Silencer
(Option) VEX
113

113
IN port IN port
1/4 1/4
23

23
OUT port
1/4
OUT port
1/4
SRH
27

27
22

22
40 4 x ø5.5 60 EXH port 4 x ø5.5 60
SRP
8.5

50 70 1/4 70
(When silencer installed: 107) (97)
SRF
(When high-noise reduction EXH port
VBA20A-03 silencer installed: 126) 1/4 VCHR
300
39
Pressure gauge (Option) ITV
28
IN side gauge port OUT side gauge port IC
1/8 1/8
ITVX
IN port
176

3/8 PVQ
43

15 Silencer (Option)
OUT port VEF
3/8 VEP
46

21
VER
24

53 98 EXH port
VEA
3.2

4 x ø12
73 118 3/8
(When silencer installed: 153.5)
VBA40A-04 (When high-noise reduction VY1
404 silencer installed: 179)
40 VBA
Pressure gauge (Option) VBAT
43
IN side gauge port OUT side gauge port AP100
1/8 1/8

IN port
1/2
215
62

8
OUT port Silencer (Option)
1/2
22
62.8

32

130 EXH port


3.2

96 4 x ø12
150 1/2
116
(When silencer installed: 200)
(When high-noise reduction
silencer installed: 230)
933
Series VBA

Dimensions
VBA22A-03 300 59
39 Pressure gauge (Option) 28
Pilot port
IN side gauge port OUT side gauge port 1/8
1/8 1/8

IN port
3/8

139
43
15
OUT port Silencer (Option)
3/8
21

46

24
53 98 EXH port
4 x ø12
3.2

73 118 3/8

(When silencer installed: 153.5)


VBA42A-04 404
(When high-noise reduction
silencer installed: 179)
40 Pressure gauge (Option) 85
43 Pilot port
IN side gauge port OUT side gauge port 1/8
1/8 1/8

IN port
1/2
62
172

8
OUT port Silencer (Option)
1/2
22
62.8

32
96 130 EXH port
4 x ø12
3.2

116 150 1/2

VBA43A-04 404
(When silencer installed: 200)
(When high-noise reduction
40 silencer installed: 230)
Pressure gauge (Option)
43
IN side gauge port OUT side gauge port
1/8 1/8

IN port
1/2
221
62

8
OUT port Silencer (Option)
1/2
22
62.8

32

96 130 EXH port


4 x ø12
3.2

116 150 1/2


(When silencer installed: 200)
(When high-noise reduction
silencer installed: 230)

For detailed dimensions, specifications


Made to Order and lead times, please contact SMC.

1 Copper-free/Fluorine-free 2 CE explosion-proof directive (ATEX) compliant 3 Ozone resistant


The inner or outer copper parts material has Ozone resistance is strengthened through
been changed to stainless steel or 56 Standard model no. the use of fluororubber (diaphragm) and
aluminum. The fluorine resin parts has been hydrogenated NBR (valve, rod seal) for the
changed to general resin. Made to Order rubber parts of the seal material.
CE explosion-proof directive (ATEX):
20 Standard model no. Category 3GD 80 Standard model no.
Made to Order Made to Order
Copper-free/Fluorine-free Ozone resistant
∗ For booster regulator with pressure gauge, please consult SMC. ∗ Weather resistant NBR (diaphragm) and
∗ This option cannot be selected for air tank with safety valve. hydrogenated NBR (valve) are used for the rubber
parts of the standard model.
934
Air Tank

Series VBAT RoHS

How to Order
Made to Order
(For details, refer to page 937.)
ARJ
AR425
to 935
• Compact connections are Standard Product
possible with booster (For Japanese Market) Note) The thread type for each port is Rc. ARX
regulators.
• It can be used alone as a tank. VBAT 10 A 1 S AMR
• Also partially compatible with Option
Tank internal
Symbol Option
ARM
overseas standards capacity
Nil None
Symbol Internal capacity
V Drain valve ARP
05 5L
10 10 L Option
20 20 L Symbol Option Applicable model
IR
38 38 L Nil None Note) All models
Safety valve VBAT05A1, VBAT10A1 IRV
Material R (Set pressure: 1 MPa) VBAT20A1, VBAT38A1
VBAT05A1 Symbol Material
S
Safety valve VBAT05A1 VEX
A Carbon steel (SS400) (Set pressure: 2 MPa) VBAT10A1
S Stainless steel 304
Note) A safety valve port is provided only when option R or S is selected. SRH
VBAT10S1
CE Certified Product SRP
SRF
VBAT 10 A F SV Q
CE certified product
VCHR
Tank internal
VBAT20S1 (Self-declaration document attached)
capacity
Symbol Internal capacity
ITV
05 5L Accessories
10 10 L Symbol Accessories Applicable model IC
20 20 L Safety valve (Set pressure: 1 MPa) VBAT20A
RV
38 38 L Drain valve VBAT38A ITVX
Safety valve (Set pressure: 2 MPa) VBAT05A
Material SV
VBAT38A1
Symbol Material
Drain valve VBAT10A PVQ
A Carbon steel (SS400) Thread type VEF
Symbol Thread type VEP
Caution Nil Rc

When used as a single unit (not


F G VER
connected with a booster regulator) and Product Not Applicable VEA
pressurized at over 1 MPa at normal to the ASME Standard
temperatures, the air tank falls under the
VY1
scope of the “High Pressure Gas Safety
Act” in Japan. VBAT 05 A N 1 SV X11 VBA
Tank internal Product not applicable VBAT
capacity to the ASME standard
Symbol Internal capacity
Option AP100
Symbol Option
05 5L
Nil None Note 1)
10 10 L
V Drain valve Note 1)
Material S Safety valve (Set pressure: 2 MPa) Note 2)
Symbol Material Safety valve (Set pressure: 2 MPa) Note 2)
SV
A Carbon steel (SS400) Drain valve
Thread type Note 1) Customers are responsible for preparing a safety
valve.
Symbol Thread type Note 2) Safety valve does not meet ASME specifications.
Nil Rc
N NPT Note)
Note) Pressure unit of NPT products: psi. This
product is for overseas use only according
to the new Measurement Law. (The SI unit
type is provided for use in Japan.)
935
Series VBAT

Specifications Design

Standard Product (For Japanese Market) Warning


1. Operating pressure
Model VBAT051 VBAT101 VBAT201 VBAT381 • Operate this product below the maximum operat-
Fluid Compressed air ing pressure. If it is necessary, take appropriate
Tank capacity (L) 5 10 20 38 safety measures to ensure that the maximum op-
erating pressure is not exceeded.
Max. operating VBATA1 2.0 1.0 • When the tank alone is used
pressure (MPa) VBATS1 2.0 Use a pressure switch or a safety valve to ensure
that the maximum operating pressure is not ex-
IN port size 3/8 3/8 1/2 1/2 ceeded.
OUT port size 3/8 1/2 1/2 3/4 2. Connection
Ambient and fluid temperature (°C) 0 to 75 • Connect a filter or a mist separator to the OUT
side of the tank. Because the inner surface of the
VBATA1 6.6 10 14 21 tank is untreated, there is a possibility of dust
Weight (kg)
VBATS1 3.2 4.9 12 19 flowing out to the outlet side.
VBATA1 Carbon steel (SS400) • A VBA booster regulator can be connected
Material directly with the tank accessories as indicated
VBATS1 Stainless steel 304 combinations below.
VBATA1 Outside: Silver paint, Inside: Rustproof paint Booster regulator
Paint
VBATS1 None
VBA1A VBA2A VBA4A
Note) The accessories and options are included in the same container. VBAT05A
VBAT05S  — —
VBAT10A
  —

Air tank
VBAT10S
CE Certified Product VBAT20A
VBAT20S
—  
VBAT05A VBAT10A VBAT20A VBAT38A VBAT38A —  
Model VBAT38S
-SV-Q -SV-Q -RV-Q -RV-Q
Fluid Compressed air
Tank capacity (L) 5 10 20 38 Selection
Max. operating pressure (MPa) 2.0 1.0
IN port size 3/8 1/2 3/4 3/4 Caution
OUT port size 3/8 1/2 1/2 3/4 • Consider the operating conditions and operate
this product within the specification range.
Ambient and fluid temperature (°C) 0 to 75 • When using the air tank with a booster regulator,
Weight (kg) 6.6 10 14 21 refer to “Sizing” on page 928 or SMC Pneumatic
Carbon steel (SS400) System Energy Saving Program.
Material
Paint Outside: Silver paint, Inside: Rustproof paint
Mounting
Note) The accessories and options are included in the same container.
Caution
1. Accessories
Product Not Applicable to the ASME Standard • Refer to the operation manual regarding combin-
ing booster regulators with older model air tanks.
Model VBAT05A1--X11 VBAT10A1--X11 • The accessories are secured by bands to the feet
Fluid Compressed air of the air tank. Once removed, make sure not to
lose them.
Tank capacity (L) 5 10
2. Installation
Max. operating pressure (MPa) 2.0 • Install the tank away from people. It is dangerous
IN port size 3/8 3/8 if the accumulated air inside the tank were to
seep out.
OUT port size 3/8 1/2 • Do not mount the air tank on a moving part or a
Ambient and fluid temperature (°C) 0 to 75 place with vibration.
Weight (kg) 6.6 11 • When connecting a booster regulator with the
tank, refer to the operation manual first, which is
Material Carbon steel (SS400) provided with the air tank before assembling.
Paint Outside: Silver paint, Inside: Rustproof paint • To mount the air tank on a floor surface, use the
four holes to secure the tank with bolts or anchor
Note) The accessories and options are included in the same container. bolts.

Maintenance
List of Air Tank for Overseas
Warning
Exportable models
Country/Region Law Details Option (Order it separately.) 1. Inspection
Material: Carbon steel Material: Stainless steel • The use of pressure vessels could lead to an un-
High Pressure Gas VBAT05A-X101 VBAT05S-X101 expected accident due to external damage or
Exempted product internal corrosion caused by drainage. Therefore,
South Safety Control Act VBAT10A-X101 VBAT10S-X101 VBAT-K (Safety valve)
Occupational Safety Max. operating pressure: make sure to check periodically for external
Korea VBAT20A-X101 VBAT20S-X101 VBAT-V1 (Drain valve)
and Health Act 0.97 MPa damage, or the extent of internal corrosion
VBAT38A-X101 VBAT38S-X101 through the port hole. An ultrasonic thickness
VBAT05A-SV-X102 Product complies with ASME indicator may also be used to check for any re-
Singapore, Factory Act VBAT10A-SV-X102 specifications duction in material thickness.
Malaysia VBAT20A-RV-X102 JBA (Japan Boiler Association) 2. Draining
VBAT38A-RV-X102 certification attached • If this product is used with a large amount of
drainage, the drainage could flow out, leading to
Thailand, Taiwan No applicable standard Standard product
equipment malfunction or corrosion inside the
tank. Therefore, drain the system once a day.

936
Air Tank Series VBAT

Options/Accessories/Part No.
<Standard Product>
For VBATA1 (Carbon Steel)
Model VBAT05A1- VBAT10A1- VBAT20A1- VBAT38A1-
Accessory kit VBAT5A-Y-3 VBAT10A-Y-3 VBAT20A-Y-3
Safety valve (When selecting an option) Note 1) 2) VBAT-R (Set pressure: 1 MPa), VBAT-S (Set pressure: 2 MPa) VBAT-R (Set pressure: 1 MPa)
Drain valve (When selecting an option) VBAT-V1
Note 1) The set pressure of the safety valve cannot be changed.
ARJ
Note 2) The safety valve is a safety measure that protects the tank from excess pressure. The valve opens automatically when the specified pressure is reached, releasing excess
pressure inside the tank. The valve closes again when the pressure drops below a designated value. Select a pressure valve appropriate for the maximum operating
AR425
pressure specification of the tank.
to 935

For VBATS1 (Stainless Steel) ARX


Model VBAT05S1- VBAT10S1- VBAT20S1- VBAT38S1-
Accessory kit VBAT5S-Y-4 VBAT10S-Y-4 VBAT20S-Y-4 AMR
Drain valve (When selecting an option) VBAT-V1

<CE Compliant Product> ARM


Model VBAT05A-SV-Q VBAT10A-SV-Q VBAT20A-RV-Q VBAT38A-RV-Q
Accessory kit VBAT5A-Y-2 VBAT10A-Y-2 VBAT20A-Y-2 ARP
Safety valve VBAT-S (Set pressure: 2 MPa) VBAT-R (Set pressure: 1 MPa)
Drain valve VBAT-V1 IR
<Product Not Applicable to the ASME Standard>
Model VBAT05A1--X11 VBAT10A1--X11 VBAT05AN1--X11 VBAT10AN1--X11 IRV
Thread type Rc NPT
Accessory kit VBAT5A-Y-3 VBAT10A-Y-3 VBAT5A-Y-3-X11 VBAT10A-Y-3-X11 VEX
Safety valve (When selecting an option) VBAT-S (Set pressure: 2 MPa) VBAT-SN (Set pressure: 2 MPa)
Drain valve (When selecting an option) VBAT-V1 VBAT-V1N SRH
The Accessory Kit is a Set of Nos. q to r. (For CE Compliant Product: ty)
Model VBAT5A-Y-3 VBAT10A-Y-3 VBAT20A-Y-3 SRP
VBAT5A-Y-2 VBAT10A-Y-2 VBAT20A-Y-2
No. VBAT5S-Y-4 VBAT10S-Y-4 VBAT20S-Y-4
Description Quantity SRF
1 (VBA1A) 1 (VBA1A)
q O-ring 1 1 1 1
1 (VBA2A) 1 (VBA2A) VCHR
Hexagon socket head taper screwed plug
w 1 1 1 1 1 1
(For drain port)
Hexagon socket head 4 (VBA1A) 4 (VBA1A)
ITV
e cap screw
4 4 4 4
4 (VBA2A) 4 (VBA2A)
r Anchor bolt/nut — — 4 — — 4 IC
t Bushing assembly — — — 1 1 1
y
Hexagon socket head taper screwed plug
— — — 1 1 1 ITVX
(For safety valve port)

Drain valve VBAT-V1∗ Safety valve VBAT-R, VBAT-S∗ PVQ


Safety
valve IN PORT VEF
1/4 VEP
ø18.5
VER
52
20
58 (CLOSE) to

65

VEA
63 (OPEN)

OUT PORT
1/8
19 VY1
3/8
Drain valve 22 VBA
ø30
(Width acrass flats 19) VBAT
For detailed dimensions, specifications
AP100
Made to Order and lead times, please contact SMC.

1 Copper-free/Fluorine-free
20 VBAT 10 A 1 V
Made to Order
Copper-free/ With drain valve
Tank internal
Fluorine-free capacity Material Note 1) The thread type for each port is Rc.
Note 2) A stainless steel fitting and a drain valve are included in the
Symbol Internal capacity Symbol Material
same container as accessories. (For detailed dimensions,
05 5L A Carbon steel (SS400)
please contact SMC.) A safety valve cannot be selected.
10 10 L S Stainless steel 304 Note 3) Since neither copper nor fluorine parts are used for the
20 20 L tank, a standard model can be used when options (safety
38 38 L valve and drain valve) are not necessary.
937
Series VBAT

Dimensions: Standard Product (For Japanese Market)

VBAT05A1 Material: Carbon steel


Tank IN port Booster regulator
Rc 3/8 Spare port IN port
Rc 1/2 Rc 1/4
Connected to VBA10A, 11A
EXH: Rc 1/4
60

(370)
OUT

(307)
Tank OUT port

257
Rc 3/8 56
ø1

163
4 x ø11
32 32

200 100
338 160
Drain port
349∗ Rc 1/4 ∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

Tank IN port
VBAT10A1 Material: Carbon steel Rc 3/8 Booster regulator
IN port
Spare port
Connected to VBA10A, 11A Rc 1/2
Rc 1/4
EXH: Rc 1/4
60

(391)
OUT

(328)
278
Tank OUT port
Rc 1/2 80
ø1
32 32 170 4 x ø11

312 120
460 Drain port 180
471∗ Rc 1/4
∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

Connected to VBA20A Connected to VBA22A


Tank IN port
Rc 3/8 Booster regulator
IN port Booster regulator IN port
Spare port Rc 3/8 Rc 3/8
Rc 1/2
EXH: Rc 3/8 EXH: Rc 3/8
(454)

442
(417)

60
(367)
(367)

OUT OUT
Tank OUT port
278

0
Rc 1/2 ø18 80
ø1
170

32 32 4 x ø11 4 x ø11

312 120 120


460 Drain port 180 180
471∗ Rc 1/4
∗ The length may be longer than the specification
if the plugs mounted on the tank are not fit to the end.

VBAT20A1 Material: Carbon steel


Connected to VBA20A, 40A Tank IN port Connected to VBA22A, 42A
Rc 1/2 Booster regulator
IN port Booster regulator IN port
Tank OUT port C
Spare port
C
Rc 1/2
Rc 1/2 EXH: C EXH: C
(A)

(A)

D
(B)

(B)

OUT OUT
305

6
ø20 4 x ø13 ø20
6
4 x ø13
180

50 50

400 100 100


674 Drain port 200 200
Rc 1/4 (mm)
685∗
Booster regulator model A B C D Note)
VBA20A 481 394 Rc 3/8 —
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
VBA40A 520 429.8 Rc 1/2 —
VBA22A 444 394 Rc 3/8 469
VBA42A 477 429.8 Rc 1/2 493
Note) When option G (pressure gauge) is selected
938
Air Tank Series VBAT

Dimensions: Standard Product (For Japanese Market)

VBAT38A1 Material: Carbon steel


Tank IN port
Connected to VBA20A, 40A Connected to VBA22A, 42A
Rc 1/2
Booster regulator IN port Booster regulator IN port
C C
Spare port ARJ
Rc 1/2 EXH: C EXH: C
AR425

(A)
Tank OUT port to 935

(A)

D
(B)

(B)
Rc 3/4 OUT OUT
ARX
355

6
ø25 56
4 x ø13 ø2 4 x ø13
205

50 50 AMR
500 150 150
824 Drain port 250 250
ARM
835∗ Rc 1/4 (mm)
Booster regulator model A B C D Note) ARP
VBA20A 531 444 Rc 3/8 —
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. VBA40A 570 479.8 Rc 1/2 —
IR
VBA22A 494 444 Rc 3/8 519
VBA42A 527 479.8 Rc 1/2 543
Note) When option G (pressure gauge) is selected
IRV
VEX
VBAT05S1 Material: Stainless steel 304
Tank IN port Booster regulator
Rc 3/8 IN port
Connected to VBA10A, 11A Rc 1/4 SRH
EXH: Rc 1/4
60 SRP
(370)

OUT
(307)

Tank OUT port


SRF
257

Rc 3/8 60
ø1
163

32 32 4 x ø11
VCHR
Drain port
100
Rc 1/4
160
ITV
200
300
IC

VBAT10S1 Material: Stainless steel 304 ITVX


Tank IN port Booster regulator
Rc 3/8 IN port
Rc 1/4
Connected to VBA10A, 11A PVQ
EXH: Rc 1/4
60 VEF
(391)

OUT VEP
(328)

Tank OUT port


278

Rc 1/2
ø1
80 VER
170

32 32 4 x ø11
VEA
Drain port 120
Rc 1/4
312
180 VY1
460 VBA
VBAT
Connected to VBA20A Connected to VBA22A
Tank IN port AP100
Rc 3/8 Booster regulator
IN port Booster regulator IN port
Rc 3/8 Rc 3/8

EXH: Rc 3/8 EXH: Rc 3/8


(454)

442
(417)

Tank OUT port


(367)
(367)

Rc 1/2 OUT OUT


278

0
ø18 80
ø1
170

32 32 4 x ø11 4 x ø11

Drain port 120 120


312 Rc 1/4 180 180

939
Series VBAT

Dimensions: Standard Product (For Japanese Market)

VBAT20S1 Material: Stainless steel 304


Connected to VBA20A, 40A Connected to VBA22A, 42A, 43A
Tank IN port
Rc 1/2 Booster regulator
IN port Booster regulator IN port
Tank OUT port C C
Rc 1/2
EXH: C EXH: C

(A)

(A)

D
(B)
(B)
OUT OUT
305

6
ø20 06
ø2 4 x ø13
180

4 x ø13
50 50

Drain port 100 100


Rc 1/4 200 200
400 (mm)
674 Booster regulator model A B C D Note)
VBA20A 481 394 Rc 3/8 —
VBA40A 520 429.8 Rc 1/2 —
VBA22A 444 394 Rc 3/8 469
VBA42A 477 429.8 Rc 1/2 493
VBA43A 526 — — —
Note) When option G (pressure gauge) is selected

VBAT38S1 Material: Stainless steel 304


Connected to VBA20A, 40A Connected to VBA22A, 42A, 43A
Tank IN port
Rc 1/2 Booster regulator
IN port Booster regulator IN port
C C

EXH: C EXH: C
(A)

Tank OUT port


(A)

D
(B)

(B)

Rc 3/4 OUT OUT


355

6
ø25 ø2
56
205

4 x ø13 4 x ø13
50 50

150 150
500
250 250
824
(mm)
Drain port Booster regulator model A B C D Note)
Rc 1/4 VBA20A 531 444 Rc 3/8 —
VBA40A 570 479.8 Rc 1/2 —
VBA22A 494 444 Rc 3/8 519
VBA42A 527 479.8 Rc 1/2 543
VBA43A 576 — — —
Note) When option G (pressure gauge) is selected

VBAT 05 R
10 A1- S VBAT 20 R
38 A1- S
With safety valve With safety valve

Safety valve port


Rc 3/8
Safety valve port
Rc 3/8
250
A
(mm)
Tank model A
VBAT05 60
VBAT10 130

940
Air Tank Series VBAT

Dimensions: CE Certified Product

VBAT05A-Q Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port Tank IN port
3/8 3/8
Spare port
Booster regulator
IN port
ARJ
2 x 1/2 1/4 AR425
EXH: 1/4 to 935
60 60 OUT

(370)
ARX

(307)
Tank OUT port

257
6
15
3/8 ø AMR

163
4 x ø11
32 32
ARM
Drain port 100
1/4 200 160
ARP
338
360∗ IR
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
The length of G thread type is about 6 mm longer due to plug type differences. IRV
VEX
VBAT10A-Q Material: Carbon steel
SRH
Connected to VBA10A, 11A
Safety valve port
SRP
3/8 Tank IN port
1/2
Booster regulator SRF
Spare port IN port
2 x 1/2 1/4
EXH: 1/4 VCHR
130 60
ITV
(391)

OUT
(328)
278

Tank OUT port


1/2 ø1
80 IC
170

32 32 4 x ø11
ITVX
Drain port 120
1/4 312 180 PVQ
460
VEF
482∗ VEP
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. VER
The length of G thread type is about 6 mm longer due to plug type differences.

VEA
Connected to VBA20A Connected to VBA22A
Tank IN port VY1
1/2 Booster regulator
Safety valve port VBA
IN port Booster regulator IN port
3/8 VBAT
Spare port 3/8 3/8
2 x 1/2 AP100
EXH: 3/8 EXH: 3/8
(454)

442∗

130 60
(417)

OUT OUT
(367)

(367)

Tank OUT port


278

1/2 80 80
ø1 ø1
170

4 x ø11 4 x ø11
32 32

312 120 120


Drain port 180 180
460 1/4
482∗ ∗ When option G (pressure gauge) is selected

∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
The length of G thread type is about 6 mm longer due to plug type differences.
941
Series VBAT

Dimensions: CE Certified Product

VBAT20A-Q Material: Carbon steel


Connected to VBA20A, 40A Connected to VBA22A, 42A
Tank IN port
3/4
Safety valve port Booster regulator
3/8 IN port Booster regulator IN port
C C

EXH: C EXH: C
Spare port

(A)
250

D
(A)
2 x 1/2 OUT OUT

(B)

(B)
Tank OUT port
305

1/2 06 06
ø2 ø2
180

4 x ø13 4 x ø13
50 Drain port 50
1/4
400 100 100
674 200
200
696∗
(mm)
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
Booster regulator model A B C D Note)
The length of G thread type is about 6 mm longer due to plug type differences. VBA20A 481 394 3/8 —
VBA40A 520 429.8 1/2 —
VBA22A 444 394 3/8 469
VBA42A 477 429.8 1/2 493
Note) When option G (pressure gauge) is selected

VBAT38A-Q Material: Carbon steel


Connected to VBA20A, 40A Connected to VBA22A, 42A
Tank IN port
3/4
Booster regulator
Safety valve port IN port Booster regulator IN port
3/8 C C
Spare port
2 x 1/2
EXH: C EXH: C
250
(A)

(A)

D
(B)

(B)

OUT OUT

Tank OUT port


355

3/4 56
56 ø2
ø2
205

4 x ø13 4 x ø13
50 50
Drain port
1/4
500 150 150

824 250 250


846∗ (mm)
Booster regulator model A B C D Note)
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
VBA20A 531 444 3/8 —
The length of G thread type is about 6 mm longer due to plug type differences.
VBA40A 570 479.8 1/2 —
VBA22A 494 444 3/8 519
VBA42A 527 479.8 1/2 543
Note) When option G (pressure gauge) is selected

942
Air Tank Series VBAT

Dimensions: Product Not Applicable to the ASME Standard

VBAT05A1-X11 Material: Carbon steel


Connected to VBA10A, 11A
Safety valve port Tank IN port
3/8 3/8
Booster regulator
Spare port IN port ARJ
1/2 1/4
EXH: 1/4 AR425
60 60
to 935

(370)
OUT

(307)
Tank OUT port
257 ARX
56
3/8 ø1
163

32 32
4 x ø11 AMR
Drain port
100
ARM
1/4

200 160 ARP


338
349∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
IR
IRV
VEX
VBAT10A1-X11 Material: Carbon steel
SRH
Connected to VBA10A, 11A
Safety valve port SRP
3/8
Tank IN port SRF
3/8 Booster regulator
Spare port IN port
1/2 1/4 VCHR
EXH: 1/4
190 ITV
(364)

OUT
(301)

Tank OUT port


IC
251

1/2 56
ø1
163

4 x ø11
32 32 ITVX
Drain port
1/4
120
PVQ
312 180
VEF
625 VEP
636∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.
VER

Connected to VBA20A Connected to VBA22A VEA

Tank IN port
VY1
3/8 Booster regulator VBA
Safety valve IN port Booster regulator IN port
port
VBAT
Spare port 3/8 3/8
3/8 1/2
AP100
EXH: 3/8 EXH: 3/8
(427)

(390)

190
(340)

(340)

OUT OUT
Tank OUT port
251

1/2 56 56
ø1 ø1
163

32 32 4 x ø11 4 x ø11

Drain port 120 120


1/4
180 180
312
625
636∗
∗ The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

943