Polarization Cell, Grounding Cell, Kirk Cell Supplier, Polarisation Cell... http://www.caltechindia.com/PolarizationCell.

htm

Home About Us Products News & Events Enquiry Form Contact Us Sitemap

Paint / Coating Testing


Instruments & Inspection Kits Polarization Cell
Cathodic Protection
Instruments & Equipments Proven, Sturdy, Durable and Economical- Also called grounding cells, protects against dangerous voltage

Corrosion Testing Polarization cell protects against induced AC current and ground fault current on buried
Instruments & Accessories pipelines. Polarisation cells permit low-level voltage of cathodic protection to uniform flow
and prevent hazardous voltages. Polarization cell consist of multiple plates of steel
Welding Inspection arranged, fixed and immersed in 30% KOH (Potassium Hydroxide) solution. Specially
Instruments & Accessories selected oil layer stop the evaporation of solution to some extend. It is advisable to verify
the solution level periodically. Polarization cell is fitted in transparent body to check
solution level. Normal storage of cell does not have any internal voltage and act as a
grounding switch in presence of high voltage. Polarisation cell works on electrochemical
principle. Installed plates with large surface area polarize and allow in developing safe DC
voltage suitable for cathodic protection. As the voltage increases from DC or AC voltage,
the polarisation film breaks and polarization cell conduct current. Specially designed
polarization cells have properties to retain solution level to the maximum period with
specially added floating oil. Polarisation cells are designed to protect personnel and
equipment from electrical disturbances

Polarisation cells control the flow of potentially dangerous AC and DC current in buried
surface protected oil & gas, water pipelines on the buried metallic structures. Grounding
cells needs to be installed with high precaution of gas ventilation. Improper installation
could produce hazardous gases resulting to cause explosion and harmful to operators.
The polrization cells are safe while using as per the rated capacity given in the information
section to prevent corrosion.

Polarisation Cell

Rated Capacity Pares of Rated Empty Weight


Model pass ½ Sec faults Plates Capacity Temp Range Weight with
Amp Max. Solution
C-5A 5000 5 30 0- 60 ºC 2.3 Kg 5.1 Kg
C-25A 25000 12 175 0- 60 ºC 32.8 Kg 41.0 Kg
C-50A 49500 25 350 0- 60 ºC 42.0 Kg 85.0 Kg
Caltech Engineering Services

D-104, Twin Arcade, Military Road, Marol, Andheri (East), Mumbai- 400 059 India
Tel: (+91-22) 29204050 / 29201454 Fax: (+91-22) 29250932 Email: info@caltechindia.com