Sei sulla pagina 1di 1

R

Alarm Annunciators - MBAS 9400


1D 1D 1D 2D

Minilec Microprocessor Based Alarm Annunciators are


designed to keep an alert & watchful eye on your plant &
processes. The entire range has been designed with an
insight into the modern day manufacturing plant & its
future requirements. Minilec Alarm Annunciators are
14B0S00 10B8S00 10B6SP0 22B10SP0
equipped with microprocessor-based design, super
bright LED facia windows, site selectable, programmed 2D 3D 4D 2D
sequences as per ISA standard & thoughtful provisions
for troubleshooting & maintenance.
Dynamic, Alert & Responsive…These unique
advantages have helped the Minilec Annunciators an
icon in the power T & D industry & engineering
establishments in India. The world class Minilec
Annunciators has made its presence felt in Overseas 28B0S00 312B0S00 416B0S00 20B16S00
markets.
PARAMETERS
Features : Supply Voltage 24 / 30 / 48 / 110 / 220 V DC 110 / 240 V AC +10% –15% 24 V AC, 90 - 270 V AC / DC
Windows 4 / 6 / 8 / 12 / 16 / 18 / 22 / 24
• Powerful Microprocessor Based circuit.
Window Sizes 30 x 30mm / 30 x 65 mm
• Built in system watchdog.
Display Device Super bright high efficiency low power consuming LED's
• First fault identification.
Facia Type Individual windows front Individual windows / Front Replaceable
• Optically isolated fault inputs. Facia with super
Window/LED Colour Standard colour available RED, Optional colours Yellow / Amber, Green
bright LEDs instead of filament lamps.
Flash Rate Fast - 60 flashes/min. Slow - 30 flashes/min.
• Site selectable fault contact configuration.
Response Time 25 msec. ± 10 msec.
(NO / NC).
Input Signal Potential free contacts (NO or NC site selectable)
• Special SMPS power supply.
Interrogation Voltage + 12 V DC
• Sleek, modern, aesthetic design
Output Contacts 1 NO + 1 NO (Optional)
• Wide range of site selectable alarm sequences. Contact Rating 5 Amps 240 V AC (Resistive)
(ISA standards). Architecture Integrated
Operational Seq. ISA Standards sequences - Auto/Manual/First-up/Ringback (optional) OR any other
sequence on request
Operational Temp. 0-60 degrees C
Power Consumption 1.5 Watts per Window
Optional Grouping / AC-DC fail Annunciation / Repeat Relay contacts
Dimensions (mm)
Panel Cutout (L x W)1D : 138 x 66 2 D : 138 x 138 3D : 138 x 210 4D : 138 x 282
Overall L x W x D 1D : 144 x 72 x 215 2D : 144 x 144 x 215
Model Coding System 3D : 144 x 216 x 215 4D : 144 x 288 x 215
2 4 B 6 S P 0 Wherever not specified Contact Rating : 5A @ 230 V AC (resistive)
* CE marked products available on request.
BOX SIZE NO. OF BIG NO. OF SMALL PUSH ADDL. FEATURE
1-1D SIZE WINDOWS SIZE WINDOWS BUTTON 1-REPEAT RELAY (A) Typical Connection Diagram
FAULT (C) To external Audible Hooter 1
2-2D 0-NIL 0-NIL 0 - ABSENT 2-GROUPING INPUTS HOOTER (connect NETWORK RDN
NC External potential RELAY across Hooter Coil)
3-3D 4-4 WINDOWS 8-8 WINDOWS P - PRESENT 3-MANNED/ free input ( NO or NC) OUTPUT To external Audible Hooter 2
NO RLY 1 : For Normal Hooter (Group 1)
C1

C2

4-4D * * UNMANNED MODE


I1

I2

RLY 2 : For Ring back


Terminal labels on Hooter or (Group 2)
F15

F16
F1

F2

* * 0- NIL
C

MBAS 9400 Terminal labels on MBAS 9400


Internal common point
* * "C" for fault inputs
24 WINDOWS 24 WINDOWS (B) (D)
REPEAT To Remote annunciator. CONTROL Control Push Buttons For Test,
RELAY PUSH Mute (Silence), Accept,
OUTPUT BUTTONS Reset Function.
Terminal labels on
FR15

FR16
FRC

FRC
FRC

FRC

RESET
FR1

FR2

Trminal labels on MBAS 9400


MUTE
TEST

MBAS 9400
ACK

(Multiple number of
Built in Fault follower MBAS 9400 annunciators
repeat relay contacts connect the Push Buttons
(NO or NC) in Parallel for all the modules.)

Dimensional Details
72 72 72 72 66 216 216 216 210
F1 F2 F1 F1 F1 F2 F1 F5 F9 F1 F5 F9 F1 F2 F9 F10 F17 F18
F3 F4 F2 F2 F3 F4 F2 F6 F10 F2 F6 F10 F3 F4 F11 F12 F19 F20
144 138 144 138
F5 F6 F3 F3 F5 F6 F3 F7 F11 F3 F7 F11 F5 F6 F13 F14 F21 F22
Ordering Information F7 F8 F4 F4 F8 F12 F4 F8 F7 F8 F15 F16
• Annunciator Series code 72
1D Panel Cutout 3D Panel Cutout
•Model Name
144 144 144 138 288 282
•No. of windows F1 F5 F1 F5 F1 F2 F9 F10 F1 F5 F9 F13
F2 F6 F2 F6 F3 F4 F11 F12 F2 F6 F10 F14
•Aux. Supply 144 138 144 138
F3 F7 F3 F7 F5 F6 F13 F14 F3 F7 F11 F15
•Operation Sequence F4 F8 F4 F7 F8 F4 F8 F12 F16

Panel Cutout Panel Cutout


•Optional Features Required 2D 4D