Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
: AGC01039140302EH01
Page 1 of 9
Health Test Report
Report No.: AGC01039140302EH01
TEST NAME : 1999/5/EC R&TTE Directive
PRODUCT
: Mobile radio
DESIGNATION
BRAND NAME : TYT
MODEL NAME : TH‐9800, TH‐9800D, TH‐7800, TH‐7900
CLIENT : TYT ELECTRONICS CO., LTD
DATE OF ISSUE : Apr. 18, 2014
EN 62311:2008
STANDARD(S) :
EN 50566:2013
REPORT VERSION : V1.0
Attestation of Global Compliance (Shenzhen) Co., Ltd.
CAUTION: This report shall not be reproduced except in full without the written permission
of the test laboratory and shall not be quoted out of context.
Report No.: AGC01039140302EH01
Page 2 of 9
TABLE OF CONTENTS
1 TEST RESULT CERTIFICATION................................................................................................................. 4
2 TECHNICAL INFORMATION ...................................................................................................................... 5
3 RF EXPOSURE MEASUREMENT .............................................................................................................. 6
3.1 INTRODUCTION .......................................................................................................................................... 6
We (AGC), Attestation of Global Compliance (Shenzhen) Co., Ltd. for compliance with the requirements set
forth in the European Standard EN62311:2008. The results of testing in this report apply to the product/system
which was tested only.
Tested By:
Bart Xie Apr. 18, 2014
Reviewed By:
Kidd Yang Apr. 18, 2014
Approved By:
Solger Zhang Apr. 18, 2014
Report No.: AGC01039140302EH01
Page 5 of 9
2. TECHNICAL INFORMATION
Note: the following data is based on the information by the applicant.
28.000MHz- 29.700MHz,50MHz-52MHz,
Frequency Range
144MHz-146MHz,430MHz-440MHz
Modulation: FM
28-29.7MHz/50-52MHz/144-146MHz:50W
Rated Output Power
430-440MHz:40W
***Note:
Please refer to the User’s manual of the EUT.
RF repeater and GSM module is the common antenna.
Report No.: AGC01039140302EH01
Page 6 of 9
3. RF EXPOSURE MEASUREMENT
3.1 INTRODUCTION
This International Standard applies to electronic and electrical equipment for which no dedicated product- or
product family standard regarding human exposure to electromagnetic fields applies.
This generic standard applies to electronic and electrical apparatus for which nodedicated product- or
product family standard regarding human exposure to electromagnetic fields applies.
The object of this generic standard is to provide assessment methods and criteria to evaluate such
equipment against basic restrictions or reference levels on exposure of the general public related to electric,
magnetic, electromagnetic fields and induced and contact current.
NOTE: This standard is intended to cover both intentional and non-intentional radiators. If the equipment
complies with the requirements in another relevant standard, e.g. EN 50371 covering low power equipment,
then the requirements of this standard (IEC 62311) are considered to be met and the application of this
standard to that equipment is not necessary.
Report No.: AGC01039140302EH01
Page 7 of 9
According to EN 62311:2008, the criteria listed in the following table shall be used toevaluate the environmental
impact of human exposure to radio-frequency (RF) radiationas specified 1999/5/EC.
Set the EUT to transmit at lowest, middle and highest channel individually at maximum power.
Note: only worst case (145MHz, 435MHz) recorded in the test report.
Report No.: AGC01039140302EH01
Page 9 of 9
6. TEST RESULTS
Note:
According to the user manual, the minimum separate distance which used for MPE calculate is 1.4m.