Calculated the transfer function for the RLC Low­pass filter, displayed on graphs, showing Bode diagram,
Nyquist diagram, Impulse response and Step response

 
RLC Filter

Vin(s)→ →Vout(s)

Transfer Function: 
45269352.648257
G(s)=
s2+2242.7501135946s+45269352.648257

www.amazon.in
R = 1.0540925533895Ω 
C = 47uF  Q factor | Damping ratio ζ
L = 470uH 
Quality factor Q =  3
Damping ratio ζ =  1
Cut­off frequency
fc = 1070.8343000955[Hz]
fc=  1000 Hz
Quality factor L =  H C =  47e­6 F
Q = 3
Give two values from three parameters of fc ,L, C. 

Select Capacitor Sequence:  E6  
Damping ratio Select Resistor Sequence:  Theory value   
Select Inductance Sequence:  E6  
ζ = 0.16666666666667

Frequency analysis
Pole(s)
Bode diagram
p = ­178.47238334924 +1055.8568589741i[Hz]
     Phase   Group delay
  |p|= 1070.8343000955[Hz]
p = ­178.47238334924­1055.8568589741i[Hz] Nyquist diagram
  |p|= 1070.8343000955[Hz] Pole, zero
Phase margin 
Oscillation analysis
Phase margin Analysis on frequency range:
  f1= ∼f2= [Hz] (optional)
pm= 27.3[deg] (f =1471.8[Hz])

Oscillation frequency Transient analysis

http://sim.okawa­denshi.jp/en/RLCtool.php 1/4
8/9/2016 RLC Low­pass Filter Design Tool ­ Result ­

f = 1055.8568589741[Hz] Step response
Impulse response
Overshoot
Overshoot (in absolute value) Final value of the step response
Analysis on time range:
The 1st peak  gpk = 1.59 (t =0.00048[sec])
  0∼ [sec] (optional)
The 2nd peak  gpk = 0.65 (t =0.00095[sec])
The 3rd peak  gpk = 1.2 (t =0.0014[sec])

Calculate
Final value of the step response (on the
condition that the system converged when t
goes to infinity)
g(∞) = 1

Frequency analysis

Gain characteristics at the Bode Diagram (provides up to 1
minute)

Phase characteristics at the Bode Diagram (provides up to
1 minute)

Bode Diagram text data (provides up to 1 minute)

http://sim.okawa­denshi.jp/en/RLCtool.php 2/4
8/9/2016 RLC Low­pass Filter Design Tool ­ Result ­

 
 
 
 
Nyquist Diagram text data (provides up to 1 minute)

Transient analysis

 
 
 
 
Step Response text data (provides up to 1 minute) 