X1 X1 X1 X1 X2 X2 NOTES:

03
_________sheet 15
of_________
S1 S2 S3 Y1 Y1 Y1 Y1 Y2 Y2
1. IF REINFORCEMENT BARS ARE OF THE
0.25L1 0.25L1
T1 T2 T3 SAME SIZE, LAPPING SHOULD BE
T1 T1 T2 T3 BUILDING AND CONSTRUCTION AUTHORITY
OMITTED WHERE POSSIBLE:
APPROVED UNDER SECTION 5 / SECTION 5A OF THE
e.g. T1 = 2T20
BUILDING CONTROL ACT (CHAPTER 29)
T2 = 2T20
S1 S2 S3 S1 S1 S2 S3
THEN T1 AND T2 SHOULD BE ONE
PROJECT REF. No.: A1166-00088-2007-ST44
CONTINUOUS BAR WITHOUT LAPPING.

B1 B2 ULTIMATE ANCHORAGE AND LAP LENGTH FOR


B1 B2 B1 B2
HIGH YIELD BAR (TYPE 2)

0.08L1 0.08L1
2
0.1L1 0.15L1 0.15L2 Fy = 460 N/mm (CONCRETE GRADE 30)
0.15L1 0.15L2 0.15L2 0.15L3
SPAN L1 SPAN L1 TENSION COMPRESSION
SPAN L2 SPAN L3 ANCHORAGE LAP ANCHORAGE LAP .............................................................
BAR SIZE
END SPAN (mm) (mm) (mm) (mm) For Commissioner of Building Control
SINGLE SPAN INTERNAL SPAN T10 400 550 300 400
T13 500 700 400 500
X1 X1 T16 600 850 500 600
T20 750 1050 600 750
T22 850 1150 650 850
T2 T3 T25 950 1300 750 950
T28 1050 1500 850 1050
T32 1200 1700 1000 1200

750
D< 750

D< 750

D< 750

1 1

2/3 D
2
2 NOTE:
S2 S1

D >
3
SR ACCREDITED CHECKER
"X1" SHALL BE THE GREATER OF 0.25L1, 0.25L2 OR ("Y1" + TENSION LAP) No: 1087
W<400 400<W<800
"Y1" SHALL BE THE GREATER OF 0.15L1, 0.15L2 OR TENSION LAP
W>800 W
"X2" SHALL BE THE GREATER OF 0.25L2, 0.25L3 OR ("Y2" + TENSION LAP)
B1 KOH KAY TEE
BEAM DEPTH > 750 "Y2" SHALL BE THE GREATER OF 0.15L2, 0.15L3 OR TENSION LAP
BUILDING CONTROL ACT
BEAM TYPE: SINGAPORE
TYPICAL SECTION FOR SPAN L1 S = SINGLE SPAN
(ACCREDITED CHECKER'S STAMP & SIGNATURE)
TYPICAL ARRANGEMENT OF LINKS SIDE REINF. (SR) CANTILEVER SPAN
E = END SPAN
C = CANTILEVER SPAN
I = INTERNAL SPAN
Date

BEAM SCHEDULE BEAM SCHEDULE


ONAL EN
SI
BEAM SPAN REINFORCEMENT STIRRUPS SIDE BAR BEAM SPAN REINFORCEMENT STIRRUPS SIDE BAR ES
GI

OF

NE
(EACH FACE) (EACH FACE)

PR

ER
CIVIL

YEOH BOON KANG


BEAM / LOCATION TYPE SIZE (W x D) L T1 T2 T3 B1 B2 S1 S2 S3 SR BEAM / LOCATION TYPE SIZE (W x D) L T1 T2 T3 B1 B2 S1 S2 S3 SR
3198

S E
W4B1 E 300 x 800 7600 3T16 4T25 - 3T20 - T10-250 T10-250 T10-100 2X2T13 W4B16 E 300 x 800 7600 3T20 3T32+3T25 - 3T32 - T13-125 T13-225 T13-100 2X2T13 IN R
G A PO

W4B1A I 300 x 800 8000 3T16 4T25 - 3T20 - T10-100 T10-250 T10-125 2X2T13 W4B16A C 300 x 800 2100 - 3T32+3T25 - 3T25 - T13-100 T13-100 - 2X2T13
Stamp & Signature of Professional Engineer
A
W4B1B I 300 x 800 8000 3T16 4T25 - 3T20 - T10-125 T10-250 T10-125 2X2T13 W4B17 C 300 x 800 1700 - 3T32 - 2T25 - T10-250 T10-250 - 2X2T13
Date
W4B1C I 300 x 800 8000 3T16 4T25+2T20 - 3T20 - T10-125 T10-250 T10-100 2X2T13
I,YEOH BOON KANG hereby certify, subject to any waiver/

modification granted under Section 14 of the Building Control


W4B1D E 300 x 800 7600 3T16 4T25+2T20 - 3T25 - T10-250 T10-250 T10-100 2X2T13 W4B17B C 300 x 800 2100 - 3T32+3T25 - 2T25 - 2T13-150 2T13-150 - 2X2T13
Act (Cap 29), that -
A
(a) the preparation of these building plans are in accordance
W4B2 E 300 x 800 7800 4T16 4T25 - 3T20 - T10-250 T10-250 T10-100 2X2T13 W4B18 S 200 x 800 3050 2T16 - - 2T20 - T10-250 T10-250 T10-250 2X2T13 with the Building Control Regulations ; and

(b) the buildings / building works shown on these plans


are in accordance with the provisions of the Building
W4B2A I 300 x 800 8000 4T16 4T25 - 3T20 - T10-100 T10-250 T10-100 2X2T13 W4B19 C 300 x 800 2100 - 3T32+3T25 - 3T25 - T13-125 T13-125 - 2X2T13
Control Regulations and the acceptable solutions in
A the Approved Document.

W4B2B I 300 x 800 8000 4T16 4T25 - 3T20 - T10-100 T10-250 T10-100 2X2T13 W4B19A E 300 x 800 8000 3T20 3T32+3T25 - 3T32 - T13-125 T13-250 T13-100 2X2T13

W4B2C I 300 x 800 8000 4T16 4T25+2T20 - 3T20 - T10-100 T10-250 T13-175 2X2T13 W4B20 C 300 x 800 2100 - 3T32+3T25 - 3T32 - T13-200 T13-250 - 2X2T13
A
W4B2D E 300 x 800 7850 4T16 4T25+2T20 - 3T25 - T13-250 T13-250 T13-150 2X2T13 W4B20A E 300 x 800 7650 3T16 3T32+3T25 - 3T32 - T13-125 T13-250 T13-150 2X2T13 A SEPT '11 KEW AMENDMENT TO APPROVE FOR ST23 BK

REV DATE NAME SUBJECT CHK'D


W4B3 S 300 x 800 9000 3T32+2T25 - - 3T32+3T32 3T32 2T13-175 T13-150 T13-125 2X2T13 W4B21 S 200 x 800 3200 2T16 - - 2T25 - T10-250 T10-250 T10-250 2X2T13
AMENDMENTS

W4B4 S 300 x 800 9200 3T16 - - 3T32 3T25 T10-100 T10-150 T10-150 2X2T13 W4B22 S 200 x 800 4400 2T25 - - 2T25+2T25 2T25+2T20 T13-200 T13-250 T13-250 2X2T13 THIS DRAWING IS COPYRIGHT

W4B24 S 200 x 800 6850 2T20 - - 2T25 2T20 T10-250 T10-250 T10-125 2X2T13

W4B25 S 200 x 800 7000 2T16 - - 2T25 - T10-250 T10-250 T10-250 2X2T13 OWNER'S NAME AND ADDRESS :

W4B6 S 200 x 800 4500 2T13 - - 2T25 - T10-250 T10-250 T10-250 2X2T13

W4B7 S 200 x 800 6150 2T16 - - 2T25 - T10-250 T10-250 T10-250 2X2T13 W4B27 S 400 x 800 7700 4T20 - - 5T25 3T20 2T10-100 2T10-125 2T10-125 2X2T16

W4B8 E 250 x 800 2900 2T32 2T32 2T32 2T16 - T10-250 T10-250 T10-250 2X2T13 W4B28 S 400 x 800 7700 4T32+2T25 - - 4T32 4T32 2T10-125 2T10-175 2T10-175 2X2T16 QUALIFIED PERSON'S /ENGINEER 'S NAME AND ADDRESS :

W4B8A E 250 x 800 7550 2T25 2T32 2T32 3T25 - T13-250 T10-250 T10-125 2X2T13 W4B29 S 400 x 800 7700 4T16 - - 5T25 3T20 2T10-225 2T10-250 2T10-250 2X2T16 bk
Consulting
Engineers Pte.
Ltd.

W4B9 S 200 x 800 6750 2T16 - - 2T20 - T10-250 T10-250 T10-250 2X2T13 W4B30 S 400 x 800 8000 4T16 - - 4T32 2T25 2T10-250 2T10-250 2T10-250 2X2T16 20 SIN MING LANE, #04-54 MIDVIEW CITY
SINGAPORE 573968
Tel: 6383 0973 Fax: 6570 9937

W4B10 E 200 x 800 2800 2T25 2T25 2T20 2T16 - T10-250 T10-250 T10-250 2X2T13 W4B31 S 400 x 800 8000 4T16 - - 4T32 2T32 2T10-175 2T10-175 2T10-175 2X2T16 Email Address : bkce@bkengr.com.sg

PROJECT

W4B10A C 200 x 800 2200 - 2T25 2T20 2T16 - T10-250 T10-250 - 2X2T13 W4B32 S 400 x 800 8000 4T16 - - 4T32 2T25 2T10-250 2T10-250 2T10-200 2X2T16
A PROPOSED ERECTION OF A 6-STOREY
W4B11 C 350 x 900 3650 - 4T32+4T32 - 3T32 - 2T13-150 2T13-150 - 3X2T16 W4B33 E 400 x 800 8000 4T16 5T25 - 4T25 - 2T10-250 2T10-250 2T10-250 2X2T16 CANADIAN INTERNATIONAL SCHOOL WITH ROOF GARDEN
ON LOTS 03869T AND NEW INCLUSION OF PART LOT
W4B11A E 350 x 900 3350 4T32+4T32 4T32+4T32 - 3T25 - T10-100 2T10-225 2T10-225 3X2T16 W4B33A E 400 x 800 8000 4T16 5T25 - 5T25 - 2T10-175 2T10-250 2T10-250 2X2T16 04139V MK 06 AT JURONG WEST STREET 41/
BOON LAY WAY (JURONG WEST PLANNING AREA)
W4B12 S 200 x 800 4900 2T13 - - 2T25 - T10-250 T10-250 T10-250 2X2T13 W4B34 S 400 x 800 2800 4T16 - - 4T16 - 2T10-250 2T10-250 2T10-250 2X2T16
DRAWING DESCRIPTION

W4B13 S 200 x 800 4525 2T16 - - 2T25 2T16 T10-250 T10-250 T10-250 2X2T13 W4B35 E 400 x 800 8000 4T16 3T32 - 3T25 - 2T10-250 2T10-250 2T10-250 3X2T16
4TH STOREY BEAM SCHEDULE 1
W4B14 E 250 x 800 6765 2T20 2T25 - 2T25 - T10-250 T10-250 T10-250 2X2T13 W4B35A E 400 x 800 8000 4T16 3T32 - 4T25 - 2T13-125 2T13-250 2T13-250 3X2T16 (BLOCK 5)

W4B14A C 250 x 800 1365 - 2T25 - 2T16 - T10-250 T10-250 - 2X2T13 W4B36 S 400 x 800 2775 4T16 - - 3T16 - 2T10-250 2T10-250 2T10-250 2X2T16
TENURE OF LAND : FREEHOLD
A
W4B37 S 200 x 800 3200 2T13 - - 2T16 - T10-250 T10-250 T10-250 2X2T13 SCALE : AS SHOWN

BY DATE
W4B38 S 200 x 800 2275 2T13 - - 2T16 - T10-250 T10-250 T10-250 2X2T13
DRAWN RAQ JUNE 2007

CHECKED SW JUNE 2007

APPROVED BK JUNE 2007

REVISION
DRAWING NO.
BK/2K7/CIS/ST44/S-03 A