PROCESS PARAMETERS Unit Properties

Str. No. Process Stream Design Flow Temperature


Number of Units: 1
A1 Product In 23000 kg/h
B3 Product Out 23000 kg/h Number of Banks per Unit: 3
A2 Exchanger Fluid In Mode of Operation: Continuous
PRODUCT IN A1
B2 Exchanger Fluid Out Product Properties
A3 Purge Air In
TOP VENT OUT B1
B1 Top Vent Out Product: Sugar Crystals
SEE NOTE 3
MP A4 Drying Air In Particle Size (Average): 0.75 mm
SEE NOTE 6 Bulk Density (Nominal): 880
Specific Heat: 0.31
AIR BALANCE Angle of Repose: 40
LIT100 LIC100

Moisture Content: 0.01 %


Heat Transfer Fluid Properties
SYMBOLS Heat Transfer Fluid: Water
LE LEVEL ELEMENT Fluid Density: 995.97

Inlet Hopper LT Fluid Specific Heat: 1


LEVEL TRANSMITTER

M Fluid Viscosity: 0.78 cP


MOTOR

PI
Heat Transfer Fluid Design Parameters
PRESSURE INDICATOR

TI
Fluid Operating Pressure Drop: 1.34 barg
TT TEMPERATURE INDICATOR
Thermal Duty per Unit: 121210 kcal/h
TE
TEMPERATURE ELEMENT
Recommended Strainer Size: 0.3 mm
TT
TEMPERATURE TRANSMITTER
PI FI Water Maximum Chloride Content: 150 ppm
FI
FLOW INDICATOR
Air Injection/Blanketing Gas Design Parameters
A3 AMBIENT AIR MP
MEASURING POINT
Vent NORMALLY Mode of Operation Purge Air
TIT OPEN FAN
MP VFD VARIABLE FREQUENCY DRIVE
Air Dew Point Temperature: 20
EXCHANGER FLUID OUT SEE NOTE 6
B2 TIT
TEMPERATURE INDICATOR TRANSMITTER Inlet Hopper Vent Design Parameters
SIC
SPEED INDICATOR TRANSMITTER Design Pressure (at vent inlet): -0.7 kPa
PI
ZIC POSITION INDICATOR TRANSMITTER Electrical
Heat Exchanger 1
LIC LEVEL INDICATOR TRANSMITTER Electrical Area Classification: Non Hazardous
PROGRAMMABLE LOGIC CONTROLLER Power Supply: 460V / 3-ph / 60Hz
FLEX CONNECTION Communication Protocol: 4-20mA HART
STRAINER
Casing Specifications

VALVE
Design Pressure: +/-0.03 barg
Design Temperature: 100
BUTTERFLY VALVE

THREE WAY CONTROL VALVE

CHECK VALVE
Pressure vessel heat exchanger plates & piping designed and fabricated in accordance with
PED 97/23/EC
PSV
PRESSURE SAFETY VALVE Pressure Design Code: AD 2000
ELECTRICAL WIRING
Module: SEP Weld Joint Factor: 0.85
PROGRAMABLE LOGIC
PIPING CE Mark: Not Applicable Design Pressure: 6.9 barg / 0 barg
Notified Body: Not Applicable Design Temperature:
Heat Exchanger 2 PED Fluid Group: 2 Test Pressure: 11.9 barg
A4

PSV

Heat Exchanger 3
RELIEF SYSTEM

Vent
TIT FI

EXCHANGER FLUID IN A2
Purchase Order Number: 4500075496
Customer Job Number:
Equipment Description: Sugar Cooler
Equipment Number: ---
Drain
Equipment Warnings: Project Name: San Jacinto
All process and water piping must be independently supported. No external loads to Location: Ancash
NORMALLY A Customer: San Jacinto, Ancash
CLOSED be applied to the heat exchanger.
B Vertical expansion joints required on all process and water connections.
VIBRATING
C All individual components must be grounded. 0 Certified Issue 2014/07/08 IW KK
FEEDER (x2) (x1) Solex heat exchanger pressure vessel rating not to be exceeded. End-user is B PARTICLE SIZE WAS 0.4 mm 2014/07/03 KK KK
Speed Alarm High
D responsible for the sizing, specification, and installation of all pressure safety valves A ISSUED FOR APPROVAL 2014/06/19 IW KK
VFD300 SIC300

M Speed Alarm Low to protect the complete pressure containment system. REV. REVISION DESCRIPTION DATE BY CHK'D APP'D
Notes:
All process instrumentation outside of Solex scope of supply is recommended as a
1
minimum to aid in commissioning, setup and operation of Solex equipment.
End-user is responsible for the sizing, specification, and installation of water system
2 strainers. Solex-recommend strainer size is recommended as a maximum opening
size to prevent build-up inside the exchanger plates. *THIS DOCUMENT IS THE PROPERTY OF SOLEX THERMAL SCIENCE, INC.
The vent flow rate is dependent on the amount of air that is being carried into the AND HAS BEEN RELEASED FOR CONFIDENTIAL USE ONLY. IT IS NOT TO BE
COMMUNICATED OR DISCLOSED TO OTHERS OR TO BE COPIED IN WHOLE
3 inlet hopper with the product. This amount of air will need to be evacuated OR IN ANY PART EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF
continuously through the vent line. SOLEX THERMAL SCIENCE, INC.*
PRODUCT OUT B3 End-user is responsible for assessing the need for insulation for personnel PROJECT SOLEX PROJECT 763
4 protection, condensation prevention and/or thermal efficiency based on site
TT conditions. DWG NAME Process Control Diagram
End-user is responsible for assessing the need for heat tracing for condensation
5 DWG. NO. 763-1000
BOTTOM VENT OUT B4 prevention and equipment thermal expansion protection.
Measuring Points, "MP", should be located three pipe diameters before and five FINISH N/A
6
pipe diameters after any flow obstructions. SHEET NO. 1 OF 1 SCALE: NTS PLOT: A1