DKG-317 MANUAL &

REMOTE START UNIT


CANBUS AND MPU VERSIONS

DESCRIPTION
The DKG-317 is a comprehensive generator
control unit designed to start and stop the
generating set both manually and remotely. The
manual control is made using the pushbuttons on
the front panel. The remote control is made via
the REMOTE START input signal.
The unit is available with MPU or CANBUS
versions. The CANBUS version connects to ECU
controlled electronic engines providing engine
control, protection and instrumentation without
extra senders.
The unit is able to initiate modem calls and send
SMS messages in fault conditions through
external modems.
The unit provides a comprehensive set of digitally
FEATURES
adjustable timers, threshold levels, input and output
configurations, operating sequences and engine True RMS measurements
types. All programs may be modified via front panel
pushbuttons, and do not require an external unit. ECU connection through J1939 CAN option
J1939 ECU warnings displayed as text
Last 100 faults are stored in the event log file. The
event log includes not only the date-time MPU input option
information, but also a comprehensive list of Dual genset mutual standby operation
measured genset parameters at the time that the Event logging with time stamp and
fault has occurred. measurements
The WINDOWS based RAINBOW program allows Battery backed-up real time clock
remote monitoring and control. Built in daily / weekly / monthly exerciser
The unit supports MODBUS protocol enabling Weekly operation schedule programs
communication with PLCs and building Field adjustable parameters
management systems. The MODBUS protocol is RS-232 serial port
also supported through GSM and PSTN modems.
Free MS-Windows Remote monitoring SW
MEASUREMENTS GSM and PSTN modem support
GSM SMS message sending on fault
Generator Volts: L1-N, L2-N, L3-N MODBUS communications
Generator Volts: L1-L2, L2-L3, L3-L1 Multiple language support
Generator Amps: L1, L2, L3 Customer logo display capability
Generator total kW
Generator total pf 10ADC relay outputs
Generator Frequency Configurable analogue inputs: 4
Engine rpm Configurable digital inputs: 7
Battery Voltage Configurable relay outputs: 2
Engine Coolant Temperature Total relay outputs: 4
Engine Oil Pressure
I/O expansion capability
Fuel Level
Engine Oil Temperature Plug-in connection system
DIGITAL INPUTS TECHNICAL SPECIFICATIONS
The unit has 7 configurable digital inputs. Each input is fully
Alternator voltage: 0 to 300 V-AC (Ph-N)
configurable with selectable names, alarm type, polling,
Alternator frequency: 0-100 Hz.
latching and contact type.
DC Supply Range: 9.0 to 33.0 V-DC
ANALOG INPUTS Cranking dropouts: survives 0 V for 100ms.
Typical Standby Current: 100 mA-DC
Engine analog inputs are provided for coolant temperature, oil Maximum Operating Current: 250 mA-DC (Relay outputs open)
pressure, oil temperature and fuel level. The inputs have DC Outputs: 10A @ 28V
programmable sensor characteristics so that they are suitable Charge excitation: min 2 Watts
for any type and brand of sensors. Magnetic pickup input:: 0.5 – 30 V-AC.
RELAY OUTPUTS Magnetic pickup frequency: 10 KHz max.
Current inputs: from CTs, .../5A. Max load 0.7VA per phase.
The unit provides 4 relay outputs and 2 of them have Analog input range: 0-5000 ohms.
programmable functions, selectable from a list. Any function or Serial port: RS-232, 9600 bauds, no parity, 1 bit stop
alarm condition may be output as a relay output. Operating temp.: -40°C (-40°F) to 70°C (158°F).
Using two Relay Expansion Modules, the number of relays
Storage temp.: -55°C (-67°F) to 80°C (176°F).
may be increased to 20, 16 of them being volt-free contacts.
Maximum humidity: 95% non-condensing.
EVENT LOGGING Dimensions: 172x 134 x 46 mm (WxHxD)
Panel Cut-out Dimensions: 151x111 mm minimum.
The unit records last 100 events with date-time stamp and a Weight: 300 g (approx.)
total of 18 measured parameters. Case Material: High Temperature ABS/PC (UL94-V0)
TELEMETRY AND REMOTE PROGRAMMING IP Protection: IP65 from front panel, IP30 from the rear
CE Conformity reference standards:
The unit provides the user with large telemetry facilities via its EN 61010 (safety requirements)
standard RS-232 serial port, connecting either to a PC, PLC or
EN 61326 (EMC requirements)
a GSM or PSTN modem. It supports both RAINBOW and
UL / CSA Conformity: certificate # 20110527-E314374
MODBUS communication protocols. The standard PC software
offers local and modem operation capabilities as well as UL 508, Edition 17
UL 2200, 1st Edition.
modem networking feature.
UL 840 Edition 3
The PC program is used for below purposes:
CSA C22.2 NO. 14 - Edition 10
-parameter upload/download
-remote monitoring and control
-diagnostics and analysis
The MODBUS interface allows the unit to be integrated in
building management systems.

DATAKOM Electronics Ltd.


Tel: +90-216-466 84 60 Fax: +90-216-364 65 65 e-mail: datakom@datakom.com.tr http: www.datakom.com.tr