Sei sulla pagina 1di 27

L-­ 7:  

Water  Quality  and  Organic  Pollution


Biochemical  Oxygen  Demand
(BOD)
Example  of  a  BOD  determination
200  mL  of  waste  water  was  collected,  aerated  and  
seeded  with  bacteria.  
The  dissolved  oxygen  content  was  7.6  mg/L  
initially.  
After  5  days,  the  dissolved  oxygen  content  had  
dropped  to  2.8  mg/L    What  is  the  BOD5 and  the  
ultimate  BOD?

(Note:  The  [dissolved  O2]  would  be  determined  by  


the  Winkler  Method  or  another  method  of  the  O2
titrations)
The  BOD5
7.6  mg/L  – 2.8  mg/L  =  4.8  mg/L

BOD5 =  4.8  mg/L

How  do  we  get  the  ultimate  BOD  from  


that?
What  about  the  temperature?
Ultimate  BOD
If  you  determine  the  BOD  after  5  days,  this  is  
called  “the  5  day  BOD” (BOD5).    

If  you  determine  the  BOD  after  20  days,  this  is  


called  “the  20  day  BOD” (BOD20).    These  are  
really  BOD  exerted  values.

The  “ultimate  BOD” is  the  amount  of  oxygen  


required  to  decompose  all  of  the  organic  
material  after  “infinite  time”.  This  is  usually  
calculated  form  the  5  or  20  day  data.
Example  of  a  BOD  determination
200  mL  of  waste  water  was  collected,  aerated  and  
seeded  with  bacteria.  

The  dissolved  oxygen  content  was  7.6  mg/L  


initially.  After  5  days,  the  dissolved  oxygen  
content  had  dropped  to  2.8  mg/L    

What  is  the  BOD5 and  the  ultimate  BOD?


The  BOD5
7.6  mg/L  – 2.8  mg/L  =  4.8  mg/L

BOD5 =  4.8  mg/L

How  do  we  get  the  ultimate  BOD  from  that?


We  assume  the  model  &  the  k
k  =  0.23  day-­1

BODu =  BOD5 =  BOD  (1-­e-­kt)


4.8  mg/L  =  BOD  (1  – e-­(0.23  days-­1)(5  days))
4.8  mg/L  =  BOD  (1-­0.3166)  =  BOD  (0.6833)

Ultimate  BOD  =  7.02  mg/L

What  does  this  number  mean?


Limitations?
1. Non-­biodegradable  organic  waste  is  
unaccounted  for.
2. Very  dirty  water  will  use  up  all  dissolved  
oxygen  before  the  5  days  is  over.
3. Other  aerobic  activity  (biological  or  just  
chemical)  is  counted.
Determining  BOD  in  polluted  sample.
200  mL  of  waste  water  was  collected,  aerated  and  
seeded  with  bacteria.    The  dissolved  oxygen  
content  was  6.9  mg/L  initially.    After  5  days,  the  
dissolved  oxygen  content  had  dropped  to  0mg/L.

A  second  test  was  run  using  a  2  mL  sample  of  


waste  water  diluted  to  200  mL,  aerated  and  
seeded.    The  dissolved  oxygen  content  was  7.6  
mg/L  initially.    After  5  days,  the  dissolved  oxygen  
content  had  dropped  to  4.3  mg/L.  What  is  the  
BOD5 and  the  ultimate  BOD?
The  Solution
7.6  mg/L  – 4.3  mg/L  =  3.3  mg/L

BOD5 =?

BODu =?
The  Solution
7.6  mg/L  – 4.3  mg/L  =  3.3  mg/L

BOD5 =  3.3  mg/L =  330  mg/L


2  mL/200  mL
Ultimate  BOD  calculation
k  =  0.23  day-­1

BOD5 =  BOD  (1-­e-­kt)


330  mg/L  =  BOD  (1  – e-­(0.23  days-­1)(5  days))
330  mg/L  =  BOD  (1-­0.3166)  =  BOD  (0.6833)

Ultimate  BOD  =  483  mg/L


Exercise:  

A  city  discharges  100  million   liters  per  day  of  domestic  sewage  into  a  
stream  whose  typical  rate  of  flow  is  250  m3 per  second.  
The  velocity  of  the  stream  is  approximately  3  km  per  hour.  The  
temperature  of  the  sewage  is  30oC,  while  that  of  the  stream  is  15oC.  
The  20oC  BOD5 of  the  sewage  is  180  mg/L,  while  that  of  the  stream  is  
1.0  mg/L.  
The  sewage  contains  no  DO,  but  the  stream  is  90%  saturated  
upstream  of  the  discharge.  Assume  saturation  level  of  DO  as  10  mg/L.
At  20oC,  de-­oxygenating  coefficient  is  estimated  to  be  0.34  per  day  
while  re-­aeration coefficient  is  0.65  per  day.

1. Determine  DO  level  at  the  critical  point  and  its  location.
2. If  DO  level  at  the  critical  point  is  less  than  4  mg/L,  what  should  
be  allowable   BOD5 of  the  wastewater.
Q/A…