Sei sulla pagina 1di 1

1 2 3 4 5 6 7 8

OBELIX LIFTING SYSTEMS VOID FORMER SIZE CALCULATOR FOR 35t LIFTERS
1511
NOM. LIFTER WLL (t) 35 EXTENT OF TRUNCATED S35t x 800 VOID FORMERS
A STANDARD DEPTHS OF OBELIX VOID FORMER (mm) 800 PULLOUT CONE PROFILE 700 2 REQUIRED EACH END OF GIRDER. A
(REF.)
MAX. CONCRETE MASS (t) to be lifted 110
n = TOTAL NUMBER OF LIFTERS IN BEAM / GIRDER 4 GIRDER BUCKET
1
SHOWN INDICATIVELY.
0 57 REFER ORIGINAL
DESIGN DRAWINGS.
TRUNCATION FACTOR PER LIFTER 0.499
RESULTS
B B
LIFTER WLL (t) at 35.00 30.76
LOAD PER LIFTER (t) = CONCRETE MASS / (n * cos ) 27.50 30.52
LIFTER FACTOR = LIFTER WLL * 5 (SAFETY RATING) / LOAD PER LIFTER 6.36 5.04

800
==
REINFORCING LOAD FACTOR = % OF LOAD TAKEN BY REINFORCING IN
40%
CONCRETE
f'c=32MPa CONCRETE FACTOR 8.06 7.27
C f'c=40MPa CONCRETE FACTOR 9.12 8.21 C
f'c=50MPa CONCRETE FACTOR 10.08 9.08
f'c=65MPa CONCRETE FACTOR 11.62 10.47
CALCULATOR NOTES: GIRDER LIFT PLAN
1. THIS CALCULATOR IS TO BE ONLY USED FOR CALCULATING OBELIX LIFTER 35T SLIMLINE THIS LIFT PLAN IS PROVIDED FOR THE
(S35T) VOID FORMERS SOLE PURPOSE TO ASSIST EXPLANATION
2. THIS CALCULATOR IS BASED ON 2 X VOID FORMERS EACH END OF GIRDER/BEAM AT 1032 1032
OF TERMINOLOGY USED IN THE ADJACENT
LOCATIONS INDICATED ON THIS DRAWING. CALCULATOR. IT IS NOT TO BE USED FOR
D D
LIFT PURPOSES.
PLAN - GIRDER END
S35t x 800 GIRDER BUCKET SHOWN
VOID FORMERS INDICATIVELY. REFER
ORIGINAL DESIGN
DRAWINGS. S35t x 800 VOID FORMERS
2 REQUIRED EACH END OF GIRDER.

E E
GIRDER BUCKET
SHOWN INDICATIVELY.

800
REFER ORIGINAL
DESIGN DRAWINGS.
1520

EXTENT OF TRUNCATED
F PULLOUT CONE PROFILE F
(REF.)
EXTENT OF TRUNCATED
GIRDER BUCKET SHOWN PULLOUT CONE PROFILE
INDICATIVELY. REFER 1400
(REF.)
ORIGINAL DESIGN
DRAWINGS.
EXTENT OF TRUNCATED
END VIEW ELEVATION - GIRDER END
G PULLOUT CONE PROFILE G
(REF.) FOR INFORMATION PURPOSES ONLY
ISOMETRIC - GIRDER END NOT TO BE USED FOR CONSTRUCTION PURPOSES
FILE NAME SHEET SCALE
GIRDER SCHEDULE GIRDERS-01.DWG 1 OF 1 DO NOT SCALE
NOTES: SIZE A2
GIRDER(S) GIRDER MARK No. DRAWN OLS FOR INFORMATION ONLY
THIS DRAWING IS INTENDED TO SHOW POSITION AND TECHINICAL INFORMATION RELATING TO THE OBELIX LIFTING LOCATION REFER ORIGINAL DESIGN DRAWINGS
H INSERTS (VOID FORMERS). FOR ALL OTHER INFORMATION REFER THE ABOVE LISTED DRAWINGS. CHECK H
APPR. FOR REFERENCE ONLY
BRIDGE XXX B1, B2, B3, B4 BRIDGE GIRDER - PRE-CAST DETAILS
ISSUED
LOCATED AT YYY DWG NO
REV

CONTRACT OBELIX LIFTING SYSTEMS PTY LTD GIRDER-01


1 2 3 6 7 8

Potrebbero piacerti anche