FLUOR DANIEL_ ELECTRICAL/CONTROL SYSTEMS

ENGINEERING APPLICATION GUIDE

TABLE OF CONTENTS
SECTION EQUIPMENTS DESCRIPTIONS PAGES REMARKS
2.1 SWITCHGEAR Selection of Continuous Current Ratings of Switchgear Above 1KV 7
2.2 Selection of Continuous Current Ratings of Switchgear Below 1KV 7
2.3 Selection of Short Circuit Duties of Switchgear Above 1KV 14 + 7 With Appendix
2.4 Selection of Short Circuit Duties of Switchgear Below 1KV 6
2.5 Selection of Voltage Rating 3
2.6 Dielectric Strength 2
3.1 TRANSFORMERS Selection of KVA Rating of Substation Transformers 9
3.2 Selection of KVA Rating of Lighting & Small Distribution Transformers 5
3.3 Selection of Transformer Impedance 11
4.1 MOTOR CONTROL Selection of Continuous Current Ratings 11
CENTERS
4.2 Selection of Short Circuit Duty 3
4.3 Selection of Voltage Rating 2
4.4 Selection of Low Voltage Starters and Contactor Sizes 4
4.5 Selection of Type of Equipment 3
4.6 Reduced Voltage Motor Starting Method 5
5.5 GENERATORS Consideration for Control & Paralleling of Generators 17
6.1 GROUNDING EQUIPT. Application and Sizing of Low Resistance Neutral Grounding Resistor 6
AND SYSTEMS
6.2 Application and Sizing of High Resistance Neutral Grounding Equipment 5
6.3 Grounding of Synchronous Generator Systems 9
6.4 Calculation for Ground Grids & Loops or Number of Ground Rods to Meet 6
Ground Resistance Requirements
6.5 Ground Grid Calculation for Substations & Switchyards 14
6.6 Sizing of Grounding Electrode Conductors 1
6.7 Sizing of Equipment Grounding Conductors 1
6.8 Measurement of Soil Resistivity 1
8 Reference Data 13
9.1 CAPACITORS Capacitor Sizing for Continuous Operation 7
9.2 Capacitor Sizing for Motor Operation 12
10.1 CABLE & BUS SYSTEM Cable Sizing Based on Ampacity Derating Factors 16
FOR PDS
10.2 Cable Sizing Based on Voltage Drop 8
10.3 Cable Sizing Based on Short Circuit Consideration 7 With Appendix
13.2 INSTRUMENT Current Transformers for Relaying Duty 12
TRANSFORMERS
14.1 PROTECTIVE Low Voltage Secondary Selective Switchgear (Auto-Transfer) 4
RELAYING
14.2 Low Voltage Secondary Selective Switchgear (Manual-Transfer) 3
14.3 Low Voltage Incoming & Feeder Breakers 3
14.4 Low Voltage Selective Relay Coordination & Settings 4
14.5 Medium Voltage Secondary Selective Switchgear (Auto-Transfer) 4
14.6 Medium Voltage Secondary Selective Switchgear (Manual-Transfer) 3
14.7 Medium Voltage Modified Spot Network (Normally Closed Tie Breaker) 4
14.8 Typical Medium Voltage Feeder Relaying 5
14.9 General Relay Setting Criteria 2
14.11 Medium Voltage Switchgear Bus Differential Relay Calculation & Setting 3
14.12 Transformer Overcurrent Protection Criteria Relay Setting & Primary Fuse 9
Selection
14.13 Transformer Differential Relay Calculation & Settings 4
14.19 Special Relaying for Captive Transformer Motors 2
14.20 Low Voltage Generators 3
14.21 Medium Voltage Generators 16
14.22 Relaying for Unit Transformer Connected Generators 4

MISSING PAGES :

Section 1, 7, 8 & 11. Section 14.3, page 2.


Section 10.3 Appendix, pages 3 & 4. Section 14.4, page 2.
Section 12.1, page 2. Section 14.19, page 2.
Section 12.2, page 2. Lighting_Training Manuals, page 1 & 2.