AGCO SISU POWER R & D: Active Faultcodes Summary

ECU SW Version: h411-0.5.1-d PRELIMINARY


Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

Coolant temp sensor voltage BELOW normal 110 4 1

COOLANT Coolant temp sensor voltage ABOVE normal or open circuit 110 3 1
TEMPERATURE Coolant temperature ABOVE NORMAL 110 16 FLm

Coolant temperature HIGH, ALARM 110 0 FLm X

Fuel temp sensor voltage below normal 174 4 1

FUEL TEMPERATURE Fuel temp sensor voltage above normal or open circuit 174 3 1

Fuel inlet temperature HIGH, ALARM (>85C) 174 0 FLm


INTAKE 1 AIR
Intake 1 air temperature ABOVE NORMAL (>90C) 105 16 1
TEMPERATURE
Oil pressure sensor voltage below normal 100 4 1

Oil pressure sensor voltage above normal or open circuit 100 3 1

OIL PRESSURE Oil pressure ABOVE NORMAL (>9,5 bar / 30C) 100 16 2

Oil pressure LOW 100 18

Oil pressure LOW, ALARM 100 1 X

Intake 1 Air Pressure sensor communication error 102 2 3

Boost pressure LOW 102 18

Intake manifold pressure drop too HIGH at cranking 102 17

INTAKE 1 AIR Boost pressure deviation too high 102 11 1


PRESSURE Boost pressure HIGH 102 0 2

Intake 1 pressure sensor signal is not plausible 102 14 2

Intake 1 pressure sensor signal is not plausible 102 12 2

Intake 1 pressure sensor signal is not plausible 102 31 2

INTAKE 2 AIR Intake 2 pressure sensor signal is not plausible 3562 14 2


PRESSURE Intake 2 pressure sensor signal is not plausible 3562 31 2

CRANKSHAFT SPEED Crank speed signal erratic, too much noise pulses 4201 2 2
SENSOR Crankshaft speed sensor signal missing 4201 31 2
WATER IN FUEL
Water in fuel 97 31 2
DETECTOR
Signal deviation between crankshaft and camshaft too large 723 8 2

CAM SPEED SENSOR Cam speed sensor signal missing 723 31 2

Number and/or position of the camshaft pulses implausible - disturbed signal 723 2 2

Fuel main filter inlet pressure sensor voltage below normal 94 4 1

Fuel main filter inlet pressure sensor voltage above normal or open circuit 94 3 1

FUEL FILTER PRESSURE Fuel main filter inlet pressure ABOVE NORMAL 94 16 1

Fuel main filter inlet pressure BELOW NORMAL 94 18 1

Fuel main filter inlet pressure ALARM, out of safe operating range 94 31 3

ECU temperature sensor voltage above normal or open circuit 1136 3

ECU TEMPERATURE ECU temperature sensor voltage below normal 1136 4

ECU over temperature HIGH, ALARM 1136 0 X

Ambient pressure sensor voltage below normal 108 4


AMBIENT PRESSURE
Ambient pressure sensor voltage above normal or open circuit 108 3

Ambient temperature sensor voltage below normal 171 4

Ambient temperature sensor voltage above normal or open circuit 171 3


AMBIENT TEMPERATURE
Ambient temperature sensor signal abnormal rate of change 171 10

Ambient temperature CAN signal missing 171 19

Fuel supply pump inlet pressure sensor voltage below normal 1381 4 1

FUEL SUPPLY PUMP Fuel supply pump inlet pressure sensor voltage above normal or open circuit 1381 3 1
INLET PRESSURE Fuel supply pump inlet pressure ABOVE NORMAL 1381 16 1

Fuel supply pump inlet pressure BELOW NORMAL 1381 18 1


AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

Grid heater voltage above normal 729 3


GRID HEATER
COOLANT Grid heater voltage below normal 729 4
TEMPERATURE
Grid heater relay voltage above normal or short to HIGH SOURCE 626 3

GRID HEATER RELAY Grid heater relay current above normal or short to GROUND 626 6

Grid heater relay current below normal or open circuit 626 5

Bus off Vehicle CAN (250k) 639 19

Bus off Engine CAN (1M) 520201 19

Torque/Speed Control (TSC1) timeout 3349 8

OHECS message has timed out 2882 8


CAN BUS
Speed Control (TSC1) timeout 898 8

All periodic TX messages cannot be allocated a send buffer in at least one timeslot. 520247 31

ECU internal fault 0132 520297 31

ECU internal fault 0133 520298 31

AIR FILTER PRESSURE Air filter pressure BELOW NORMAL 107 18


MONITORING Air filter pressure sensor active at init state 107 31

Battery voltage ABOVE NORMAL(>17V(12V)) (>32V(24V)) 168 0

Battery voltage BELOW NORMAL (<7.8V) 168 1


BATTERY VOLTAGE
Powerstages could be disabled due to high Battery voltage 520200 16

Powerstages could be disabled due to low Battery voltage 520200 18

Accelerator pedal 1 sensor below normal (IDLE) 91 4


ACCELERATOR PEDAL 1
Accelerator pedal 1 sensor above normal or open circuit (IDLE) 91 3

Accelerator pedal 2 sensor below normal (IDLE) 29 4


ACCELERATOR PEDAL 2
Accelerator pedal 2 sensor above normal or open circuit (IDLE) 29 3

Accelerator pedal 3 sensor below normal (IDLE) 974 4


ACCELERATOR PEDAL 3
Accelerator pedal 3 sensor above normal or open circuit (IDLE) 974 3

Fan control output current above normal 977 6

Fan control output open circuit 977 5


FAN
Fan control output short circuit to HIGH SOURCE 977 3

Fan speed request CAN signal missing 1639 19

Engine specification mismatch 520230 31

ENGINE PROTECTION Adaptive oil change interval exceeded 1378 31

Engine Speed ABOVE NORMAL 190 16

Coolant pressure sensor voltage above normal or open circuit 109 3


COOLANT PRESSURE
Coolant pressure sensor voltage below normal 109 4

PTO input error 520231 31

DIGITAL INPUTS Bad digital input configuration 520232 31

Error in torque control input 520205 31

Auxiliary analog input 1 voltage above normal or open circuit 1083 3

Auxiliary analog input 1 voltage below normal 1083 4


AUXILIARY ANALOG
Auxiliary analog input 2 voltage above normal or open circuit 1084 3

Auxiliary analog input 2 voltage below normal 1084 4

Main relay lamp short circuit to ground 520243 6

MAIN RELAY LAMP Main relay lamp short circuit to battery 520243 3

Main relay lamp open load 520243 5

Customer fault 1 via digital input 520237 31


CUSTOMER FAULT
Customer fault 2 via digital input 520238 31

Start relay current below normal or open circuit 677 5

Start relay low side voltage above normal or short to HIGH SOURCE 677 3

START RELAY Start relay low side current above normal 677 6

Start relay high side voltage above normal 1321 3

Start relay high side current above normal 1321 6

INTAKE MANIFOLD 1 Intake manifold 1 air temperature sensor voltage below normal 1132 4 1
TEMPERATURE Intake manifold 1 air temperature sensor voltage above normal or open circuit 1132 3 1
AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

Field test Field test software expired 520293 31 2

COOLANT Rail 1 pressure sensor voltage below normal 157 4 3


TEMPERATURE Rail 1 pressure sensor voltage above normal or open circuit 157 3 3

Rail Pressure control: Pressure raw value is intermittent 157 2

Rail Pressure control: Pressure raw value is above maximum offset 157 20

Rail Pressure control: Pressure raw value is below minimum offset 157 21

Rail Pressure control: Pressure CRITICAL HIGH 157 16

Rail Pressure control: Pressure ABOVE measurable range 520307 31

Rail Pressure control: Over pressure protection mode activated 520388 31

Rail Pressure control: Maximum over pressure protection mode entries reached 520309 31
RAIL 1 PRESSURE
Rail Pressure control: Maximum time in limp home state is exceeded 520312 31

Rail Pressure control: Pressure reduction interrupted 520317 31

Rail Pressure control: Forced engine shutdown 520336 31

Rail Pressure control: Torque limited due rail over pressure 520337 31

Rail Pressure control: Pressure deviation in limp home mode 520318 31

Rail Pressure control: Pressure BELOW normal in limp home mode 520207 31

Rail Pressure control: Pressure ABOVE normal in limp home mode 520320 31

Rail Pressure control: Pressure out of range in limp home mode 520319 31

Rail Pressure control: Pressure ABOVE NORMAL 520327 31

SHORT CIRCUIT low side to ground in the pressure control valve. 520354 4

SHORT CIRCUIT low side to battery voltage in the pressure control valve. 520354 3

PRESSURE CONTROL SHORT CIRCUIT to ground in the high side of the pressure control valve. 520356 4
VALVE SHORT CIRCUIT to battery in the high side of the pressure control valve. 520356 3

Over teperature of device driver of pressure control valve 520358 31

Open load of pressure control valve output 520359 31

Rail pressure controller, Positive deviation 157 15 3

Rail pressure controller, Negative deviation at low idle 157 17 3

Rail pressure below normal 520233 31


RAIL PRESSURE
Rail pressure above normal 157 0 3 X
MONITORING
Rail pressure, Leakage detected at low idle 1240 14 3

Rail pressure, Leakage detected at load condition 1239 14 3

Rail pressure controller, Negative deviation 520229 31

ECU 1 Injector bank 0 short circuit 520240 31


INJECTOR BANK
ECU 1 Injector bank 1 short circuit 520241 31
MONITORING
ECU 1 Injector bank 2 short circuit 520242 31

MPROP control, High side short circuit to GROUND 1076 6

MPROP control, Low side short circuit to GROUND 1076 4

MPROP control, High side short circuit to HIGH SOURCE 1076 3


MPROP
MPROP control, Low side short circuit to HIGH SOURCE 1076 5

MPROP control, Open circuit 1076 14

MPROP control, Powerstage over temperature 1077 31

Engine injector cylinder #1, Current below normal: Open circuit 651 5 3
ENGINE INJECTOR
Engine injector cylinder #1, Short circuit 651 14 3
CYLINDER #1
Engine injector cylinder #1, Calibration value missing 651 13 3

Engine injector cylinder #2, Current below normal: Open circuit 652 5 3
ENGINE INJECTOR
Engine injector cylinder #2, Short circuit 652 14 3
CYLINDER #2
Engine injector cylinder #2, Calibration value missing 652 13 3

Engine injector cylinder #3, Current below normal: Open circuit 653 5 3
ENGINE INJECTOR
Engine injector cylinder #3, Short circuit 653 14 3
CYLINDER #3
Engine injector cylinder #3, Calibration value missing 653 13 3
AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

Engine injector cylinder #4, Current below normal: Open circuit 654 5 3
ENGINE INJECTOR
COOLANT#4 Engine injector cylinder #4, Short circuit 654 14 3
CYLINDER
TEMPERATURE
Engine injector cylinder #4, Calibration value missing 654 13 3

Engine injector cylinder #5, Current below normal: Open circuit 655 5 3
ENGINE INJECTOR
Engine injector cylinder #5, Short circuit 655 14 3
CYLINDER #5
Engine injector cylinder #5, Calibration value missing 655 13 3

Engine injector cylinder #6, Current below normal: Open circuit 656 5 3
ENGINE INJECTOR
Engine injector cylinder #6, Short circuit 656 14 3
CYLINDER #6
Engine injector cylinder #6, Calibration value missing 656 13 3

Engine injector cylinder #7, Current below normal: Open circuit 657 5 3
ENGINE INJECTOR
Engine injector cylinder #7, Short circuit 657 14 3
CYLINDER #7
Engine injector cylinder #7, Calibration value missing 657 13 3

Engine injector cylinder #8, Current below normal: Open circuit 658 5 3
ENGINE INJECTOR
Engine injector cylinder #8, Short circuit 658 14 3
CYLINDER #8
Engine injector cylinder #8, Calibration value missing 658 13 3

CY146 error 1 520260 31

CY146 error 2 520261 31

CY146 CY146 error 3 520262 31

CY146 error 4 520263 31

CY146 error 5 520264 31

5Vdc Supply 1 voltage out of range 3509 31


5Vdc REFERNCE
5Vdc Supply 2 voltage out of range 3510 31
SUPPLIES
5Vdc Supply 3 voltage out of range 3511 31

12V sensor supply 1 voltage above normal 3512 3

12V sensor supply 1 voltage below normal 3512 4


12V SUPPLY
internal 12V supply voltage above normal 1043 3

internal 12V supply voltage below normal 1043 4


MAIN RELAY Main relay early opening at previous afterrun 1485 31

MOCSOP (Test of ECU internal fault 0108 520215 31


redundant shut-off paths) ECU internal fault 0109 520216 31

DOC inlet temp sensor voltage above normal or open circuit 4753 3 X
DOC INLET
DOC inlet temp sensor sensor voltage below normal 4753 4 X
TEMPERATURE
DOC inlet temperature value not plausible 4753 10 X

SCR catalyst inlet gas temp sensor voltage above normal or open circuit 4360 3 X

CATALYST INLET SCR catalyst inlet gas temp sensor voltage below normal 4360 4 X
TEMPERATURE SENSOR SCR catalyst inlet gas temp sensor value abnormal rate of change 4360 2 X

SCR catalyst inlet temperature value not plausible 4360 10

SCR catalyst outlet gas temp sensor voltage above normal or open circuit 4363 3 X

CATALYST OUTLET SCR catalyst outlet gas temp sensor voltage below normal 4363 4 X
TEMPERATURE SENSOR SCR catalyst outlet gas temp sensor value abnormal rate of change 4363 2 X

SCR catalyst outlet temperature value not plausible 4363 10


AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

Upstream NOx sensor missing or unavailable 3216 19 X

COOLANT Upstream NOx sensor value implausible 3220 2 X


TEMPERATURE
Upstream NOx sensor stability time exceeded 3220 12 X

Upstream NOx sensor supply voltage out of range 3218 14 X

Upstream NOx sensor maximum heating time exceeded 3219 2 X

Upstream NOx sensor value offset check error 5026 2 X

Upstream NOx sensor value peak check error 521016 31 X

Upstream NOx sensor value stuck 521017 31 X


UPSTREAM NOX
Upstream NOx sensor calibration values outside limits 5025 31 X
SENSOR (intake)
Upstream NOx sensor calibration values outside limits 5028 31 X

Upstream NOx sensor calibration NOT AVAILABLE or incompatible sensor 5028 13 X

Upstream NOx sensor reports NOx measurement short circuit 3224 3

Upstream NOx sensor reports NOx measurement open wire 3224 5

Upstream NOx sensor reports heater short circuit 3222 3

Upstream NOx sensor reports heater open wire 3222 5

Upstream NOx sensor reports O2 short circuit 3225 3

Upstream NOx sensor reports O2 open wire 3225 5

Downstream NOx sensor missing or unavailable 3226 19 X

Downstream NOx sensor value implausible 3230 2 X

Downstream NOx sensor stability time exceeded 3230 12 X

Downstream NOx sensor supply voltage out of range 3228 14 X

Downstream NOx sensor maximum heating time exceeded 3229 2 X

Downstream NOx sensor value offset check error 5033 2 X

Downstream NOx sensor value peak check error 521012 31 X

Downstream NOx sensor value stuck 521013 31 X


DOWNSTREAM NOX
Downstream NOx sensor calibration values outside limits 5032 31 X
SENSOR (outlet)
Downstream NOx sensor calibration values outside limits 5035 31 X

Downstream NOx sensor calibration NOT AVAILABLE or incompatible sensor 5035 13 X

Downstream NOx sensor reports NOx measurement short circuit 3234 3

Downstream NOx sensor reports NOx measurement open wire 3234 5

Downstream NOx sensor reports heater short circuit 3232 3

Downstream NOx sensor reports heater open wire 3232 5

Downstream NOx sensor reports O2 short circuit 3235 3

Downstream NOx sensor reports O2 open wire 3235 5

DEF pump motor control signal current below normal or open circuit 4375 5 X

DEF pump motor control powerstage over temperature 4375 31 X

DEF pump motor control signal short circuit to HIGH SOURCE 4375 3 X

DEF PUMP MOTOR DEF pump motor control signal short circuit to GROUND 4375 4 X

DEF pump motor speed deviation 4374 8 X

DEF pump motor speed permanent deviation 4374 14 X

DEF pump motor not available for actuation 4374 31 X

DEF pressure sensor voltage above normal or open circuit 4334 3 X


DEF PRESSURE SENSOR
DEF pressure sensor voltage below normal 4334 4 X

DEF PUMP DEF pump temperature signal duty cycle in failure range 521000 8
TEMPERATURE DEF pump temperature signal duty cycle in invalid range 521000 2

DEF supply module heater temperature signal in failure range 4344 8 X


DEF SUPPLY MODULE
DEF supply module heater temperature signal in invalid range 4344 2 X
TEMPERATURE SENSOR
DEF supply module temperature measurement module is not reponding 4344 12

DEF pump direction valve low side current below normal or open circuit 4376 5 X

DEF PUMP DIRECTION DEF pump direction valve low side short circuit to HIGH SOURCE 4376 3 X
VALVE DEF pump direction valve low side short circuit to GROUND 4376 4 X

DEF pump direction valve low side control powerstage over temperature 4376 31 X
AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

DEF dosing valve powerstage driver chip over temperature 3361 31

COOLANT DEF dosing valve low side short circuit to HIGH SOURCE 3361 3 X
TEMPERATURE
DEF dosing valve high side short circuit 3361 4 X

DEF DOSING VALVE DEF dosing valve current abnormal behaviour 3361 14 X

DEF dosing valve low side short circuit to GROUND or open load 3361 6 X

DEF dosing valve high side short circuit to HIGH SOURCE or open load 3361 5 X

DEF dosing valve is blocked 3361 7 X

DEF tank temperature sensor voltage above normal or open circuit 3031 3 X

DEF tank temperature sensor voltage below normal 3031 4 X

DEF tank maximum defrost time exceeded 3031 14 X

DEF tank temperature abnormal rate of change at heating cycle 3031 10

DEF tank temperature ABOVE normal 3031 16

DEF tank temperature signal abnormal rate of change 3031 2 X

DEF tank temperature sensor general error 3031 11

DEF TANK DEF tank sensor open circuit 3519 3


TEMPERATURE SENSOR DEF tank sensor short circuit 3519 4

DEF tank temperature error 3031 15

DEF tank temperature error 3031 17

DEF tank temperature sensor general error 3515 11

DEF tank temperature sensor open circuit 3515 3

DEF tank temperature sensor short circuit 3515 4

DEF tank temperature error 3515 15

DEF tank temperature error 3515 17

DEF tank level sensor voltage above normal or open circuit 1761 3 X

DEF tank level sensor voltage below normal 1761 4 X

DEF tank EMPTY 1761 1 X

DEF tank LEVEL LOW 1761 18 X

DEF tank level sensor CAN message missing 1761 31


DEF TANK LEVEL
DEF tank level sensor general error 1761 11

DEF tank level sensor open circuit 3532 3

DEF tank level sensor short circuit 3532 4

DEF tank level error 1761 15

DEF tank level error 1761 17

SCR system ERROR: DEF backflow line blocked or implausible 521007 10 X

SCR system ERROR: DEF pressure line or dosing valve blocked 521007 14 X

SCR system ERROR: DEF pressure stabilisation failure 521007 31 X

SCR system ERROR: DEF dosing pressure above normal 4332 16 X

SCR system ERROR: DEF dosing pressure below normal 4332 18 X

SCR system ERROR: Pressure drop test failure 4332 14 X


SCR SYSTEM
SCR system ERROR: Emptying not completed at previous shutdown 4332 31

SCR system ERROR: Pumped-Dosed quantities balance error 4332 11 X

SCR system ERROR: DEF over pressure detected 4332 0 X

SCR system ERROR: DEF pressure reduction failure 521008 0 X

SCR system ERROR: Emergency shutoff was performed due heating system error(s) 521002 31 X

SCR system ERROR: DEF pressure build up failure 521008 1


AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

DEF tank heater coolant valve solenoid high side short circuit to HIGH SOURCE 3363 14

COOLANT DEF tank heater coolant valve solenoid high side short circuit to GROUND 3363 4
TEMPERATURE
DEF tank heater coolant valve solenoid low side open circuit 3363 5
DEF TANK HEATER
DEF tank heater coolant valve low side power stage over temperature 3363 31

DEF tank heater coolant valve solenoid low side short circuit to HIGH SOURCE 3363 3

DEF tank heater coolant valve solenoid low side short circuit to GROUND 3363 6

DEF heater relay open circuit 521001 5

DEF heater relay powerstage over temperature 521001 31


DEF HEATER RELAY
DEF heater relay shorted to battery 521001 14

DEF heater relay shorted to ground 521001 4

DEF pressure line heater control circuit open circuit 4346 5

DEF PRESSURE LINE DEF pressure line heater control circuit short circuit to HIGH SOURCE 4346 3
HEATER DEF pressure line heater control circuit short circuit to GROUND 4346 4

DEF pressure line heater ECU power stage over temperature 4346 31

DEF suction line heater control circuit open circuit 4340 5

DEF SUCTION LINE DEF suction line heater control circuit short circuit to HIGH SOURCE 4340 3
HEATER DEF suction line heater control circuit short circuit to GROUND 4340 4

DEF suction line heater ECU power stage over temperature 4340 31

DEF backflow line heater control circuit open circuit 4342 5

DEF BACKFLOW LINE DEF backflow line heater control circuit short circuit to GROUND 4342 4
HEATER DEF backflow line heater ECU power stage over temperature 4342 31

DEF backflow line heater control circuit short circuit to HIGH SOURCE 4342 3

DEF supply module heater open circuit 4344 5

DEF SUPPLY MODULE DEF supply module heater control circuit short circuit to HIGH SOURCE 4344 3
HEATER DEF supply module heater control circuit short circuit to GROUND 4344 4

DEF supply module heater ECU power stage over temperature 4344 31

DEF quality sensor: Fluid is Diesel 3521 31

DEF quality sensor: Fluid quality unknown 3521 14

DEF quality sensor: Urea concentration too low 3521 18

DEF quality sensor: Urea concentration too high 3521 16

DEF QUALITY DEF concentration general error 3516 11

DEF concentration sensor error 3516 2

DEF concentration not valid 3516 15

DEF concentration not valid 3516 17

Aftertreatment 1 Diesel Exhaust Fluid Information -message not present 3516 19

SCR effiency threshold 1 exceeded 521018 31 X

SCR effiency threshold 2 exceeded 521019 31 X

SCR effiency threshold 3 exceeded 521020 31 X

NOx limits exceeded due to Interrupted DEF dosing 4095 31 X

SRC catalyst overtemperature 4792 14

SCR MONITORING Possible exhaust line temperature sensor interchange 521022 31

Possible exhaust line Nox sensor interchange 521023 31

Relative O2 concentration error between upstream and downstream Nox sensors 521024 31

NOx limits exceeded, root cause unknown 4090 31

SCR efficiency not OK 521025 31

SCR efficiency not OK after DEF refill (possible bad quality) 521026 31
AGCO SISU POWER R & D: Active Faultcodes Summary
ECU SW Version: h411-0.5.1-d PRELIMINARY
Generated: 16.10.2013 15:09:24
FLm = Fuel limit by map
Degradation 1 = 75% from max power
Degradation 2 = 50% from max power + Speed Limit 1800 rpm
Degradation 3 = 50% from max power + Speed Limit 1500 rpm

Degradation

Degradation

Shutdown
Emission

(delayed)
SPN

FMI
FAULT DESCRIPTION

WG Actuator 1 initialization error (ERROR 6) 5451 14 2

COOLANT WG Actuator 1 communication error (ERROR 7) 5370 19 2


TEMPERATURE
WG Actuator 1 position deviation (ERROR 3) 1188 2

WG Actuator 1 short cut (ERROR 21) 5451 4 2

WASTEGATE ACTUATOR WG Actuator 1 temperature alert (ERROR 1) 5372 0


1 WG Actuator 1 temperature warning (ERROR 2) 5372 16

WG Actuator 1 torque limited (ERROR 22) 1188 11

WG Actuator 1 calibration error (ERROR 4) 1188 13 2

WG Actuator 1 motor unpowered due fault condition (ERROR 5) 1188 7 2

WG Actuator 1 not present 5451 31 2

EGR Valve communication error 2791 9 2

EGR Valve initialization error 2791 10 2

EGR Valve not present 2791 31 2

EGR Valve overload 27 6


EGR VALVE
EGR Valve position deviation 27 7

EGR Valve short cut 27 12 2

EGR Valve temperature alert 2791 0

EGR Valve mechanical fault 27 13 2 X

Air Mass Flow Sensor Absolute Pressure sensor defective 520382 14 X

Air Mass Flow Sensor Differential Pressure sensor defective 520383 14 X

Air Mass Flow Sensor over temperature warning 520384 16 X

Air Mass Flow Sensor temperature sensor defective 520384 14 X

Air Mass Flow Sensor CAN communication timeout 132 19 X


AIR MASS FLOW
Air Mass Flow zero calibration failed 132 13
SENSOR
Air Mass Flow Sensor signal is not plausible 132 2 X

Air mass sensor pressure signal is not plausible 520382 2 X

Air mass sensor value not plausible 520389 31 X

Air mass sensor start test time exceeded 520390 31 X

Air mass sensor start test value not plausible (too high) 520391 31 X

Throttlevalve 1 Calibration Error 51 13 1

THROTTLE VALVE 1 Throttlevalve 1 Voltage Above Normal 51 3 1

Throttlevalve 1 Voltage Below Normal 51 4 1

ThrottlvValve 2 Calibration Error 3573 13 1

THROTTLE VALVE 2 Throttlevalve 2 Voltage Above Normal 3573 3 1

Throttlevalve 2 Voltage Below Normal 3573 4 1