Sei sulla pagina 1di 2

CRYOGENIC PRESSURE TRANSDUCER

MODEL 311-CRYO
FEATURES:
• Cryogenic service down to -320 °F (-196 °C)
• ATEX & CSA, Intrinsically Safe available
• Remote mounted electronics for 4-20 mA or 0 to 5 Vdc output
• Pressure ranges from 0-150 thru 0-5K PSI (10 thru 345 BAR)
• Low-cost industrial grade

APPLICATIONS:
• LNG (Liquefied Natural Gas) processing, transportation
& storage
• CNG (Compressed Natural Gas)
• Oil field nitrogen pumping

PRODUCT OVERVIEW:
Model 311-Cryo GP:50’s 311-Cryo series provides cryogenic pressure
Cryogenic Pressure Transducer measurement down to -320 °F (-196 °C). The remote mounted
electronics offers a high level output of 4-20 mA or 0 to 5 Vdc and
a direct mount sensor gives more accurate readings of the process
media.

FIELD OPTIONS:
ATEX & CSA IS Hazardous Approvals
Alternate remote electronics cable lengths
Zero and span adjusts
High-temp operation to +350 °F

© 2014 GP:50 NY Ltd. | 2770 Long Road, Grand Island, NY 14072 USA A5SL-016
Tel: +1.716.773.9300 Fax: +1.716.773.5019 Email: sales@gp50.com Web: www.gp50.com
GP:50 MODEL 311-CRYO
DIMENSIONAL DRAWING
All dimensions are in inches (mm)
5.10 [129.46]

4.58 [116.36]
3.42 [86.87]

18" SST
ARMORED CABLE

Ø1.50
[38.10] STANDARD WIRING

MODEL
PIN
311-CRYO
A/1 +EXC/SIG
B/2 CASE GND
C/3 N/C
AS4395E04 D/4 -EXC/SIG
E/5 N/C
F/6 N/C

Ø1.00 [25.40]

3.26 [82.78]
3.78 [95.89]

REFERENCE SPECIFICATIONS
ELECTRICAL MECHANICAL
• Output Signal: 0 to 5 Vdc, 0 to 10 Vdc and 4-20 mA • Process connection: AS4395E04 pressure port
• Excitation Voltage:
• Proof Pressure: 1.5X Pressure Range
(Ma Output) 10 to 28 Vdc
(Voltage Output) 14.5 to 32 Vdc • Burst Pressure: 2X Pressure Range
• Response Time: <4 ms • Approximate Weight: 1 lb (0.5 kg)
• Connection: PTIH-10-6P Bendix
PRESSURE RANGES
MATERIALS OF CONSTRUCTION
• Port/Sensor: 17-4PH stainless steel • 150 PSI thru 5K PSIG (10 thru 345 BAR) Sealed Gauge, Absolute
(Inconel, Hastelloy, Monel optional)
THERMAL SPECIFICATIONS
• Armored cable: 316L
• Housing: 316/316L • Compensated: -320 °F to +70 °F (-196 °C to +21.1 °C)
• Operating Range:
STATIC ACCURACY (BFSL) (HYSTERESIS, NON-LINEARITY & REPEATABILITY @ +70 °F)
(Ambient) -40 °F to +185 °F (-40 °C to +85 °C)
Standard: 0.5% FSO
• Effect on Zero/Span:
Improved: 0.2% FSO
±1.0% FSO/100 °F for ranges≥ 1K PSI (69 BAR)
±2.0% FSO/100 °F for ranges <1K PSI (69 BAR)

All specifications are for reference purposes only. In the interests of continuous product improvement, all specifications are subject to change without notice. Please contact
GP:50 for assistance with your application.

©
2014 GP:50 NY Ltd. | 2770 Long Rd, Grand Island, NY 14072 USA
Tel: +1.716.773.9300 Fax: +1.716.773.5019 Email: sales@gp50.com Web: www.gp50.com