Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
DEMOUNTABLE- Flatpack
The standard container for various purposes is suitable for international container transport. It is of
appropriate external dimensions and has connections for lifting and fixing or compounding. The container is
designed as a light construction consisting of floor and roof frames and corner profiles. The construction
enables compounding of individual containers in longitudinal and transverse directions without limits. It also
enables compounding of containers in 2 floors in height (ground floor + first floor), or 3 floors in height
(ground floor + 2 floors). The wainscots of the container are made of light insulation panels and offer
pleasant climate in the interior due to their building and physical properties. Used materials are
environmental friendly. Containers can be delivered assembled or individually – in packages 648mm high.
Packages of 4 kits each 2591mm high.
FLATPACK
Container Houses are designed according to ISO 1161 for
various purposes i.e hospital, dormitory, office, storeroom
etc. also are suitable for international container transport.
Weight
• 2000kg per unit (4 units per bundle)
FLATPACK
Project Sample Of Demountable Container Modules
PRODUCTION TYPE
The standard Flatpacked unit for various purposes
suitable for international transport. It has appropriate
external dimensions and has connections for lifting and
fixing or compounding. The Flat packed unit is designed
as light construction consisting of floor and roof frames
and corner profiles. The construction enables
compounding of individual flatpacked units in longitudinal
and transverse direction without limits. Furthermore, it
enables compounding of flatpacked units in 2 floors
height (ground floor +first floor), or in three floors in the
height for warehousing of these flatpacked units (ground
floor + 2 floors). The wainscots of the flatpacked unit are
made of light insulation panels and offer pleasant climate
in the interior due to their building and construction
properties.
TECHNICAL DATA
All statical calculations and design should be arranged
due to the wind speed, earthquake zone, weather
conditions of the location where the building is going to
be installed
Standard Production Conditions Wind 145 km/hour
Speed
Earthquake Effective ground acceleration coefficient: Ao
= 0,40 ( 1st Degree earthquake zone )
Standard Production Conditions
Building importance coefficient ( I =1)
Earthquake
Live Load joining coefficient (n = 0,3)
(due to the purpose and type of usage of the building, it
is calculated like this;I=1 / 1,2 / 1,4 / 1,5 , n = 0,3 / 0,6 )
STEEL FRAMEWORK
MATERIAL Cold formed steel profiles on a thickness of 3 to 4 mm.
SURFACE WORKING Sand blasting, total ground coat of minimum 120 mm
FITTINGS Locking holes according to international ISO standard
1161.
TECHNICAL SPECIFICATIONS
.
FLATPACK
FLOOR
COMPOSITION External wainscot: galvanized steel sheet metal in a
thickness of 0.6 mm.
INSULATION FILLING Mineral wool among transverse supports
STEAM BLOCKADE PE foil; waterproof chipboard panel.
COVERING Glued final PVC floor covering in a thickness of 1.5 mm
with shield connections.
FLOOR HEAT TRANSMISSION k = 0.32 W/m2K
COEFFICIENT
PERMITTED LOAD CAPACITY 200 kg/m2 Calculated in accordance with TS 498
EXTERNAL DIMENSIONS
EXTERNAL LENGHT 6058mm (+/- 6mm)
EXTERNAL WIDTH 2438mm (+/- 5mm)
CEILING
COMPOSITION External wainscot: flat galvanized and painted steel
sheet metal in a thickness of 0.6 mm.
INSULATION FILLING Mineral wool among wood purlins
STEAM BLOCKADE PE foil; waterproof chipboard panel.
INNER WAINSCOT Chipwood panel
METEOR WATER OUTLETS 4 each of PVC rainwater pipes
FLOOR HEAT TRANSMISSION k = 0.32 W/m2K
COEFFICIENT
PERMITTED LOAD CAPACITY 1.00 KN/m2
WINDOW Two (2) windows are made of PVC, single fold, white
color, in dimensions approx 885/1200 mm- or per request
DOORS External doors: one (1) single fold, filled door, light
opening approx 810/2000 mm-or per request
FACADE WALLS
COMPOSITION External wainscot: shallow profiled, galvanized and
painted steel sheet metal in a thickness of 0.55 mm.
INSULATION FILLING non combustible
METEOR WATER OUTLETS 4 each of PVC rainwater pipes
FLOOR HEAT TRANSMISSION k = 0.32 W/m2K
COEFFICIENT
PERMITTED LOAD CAPACITY 1.00 KN/m2
TECHNICAL SPECIFICATIONS
.
FLATPACK
ELECTRICAL SYSTEM Standard: According to VDE 100 regulation
Voltage: 220/240 V, 50Hz 3X2.5 mm²
Network connection: CEE-connection plug sockets, 5-pole
5x32 A, 380V, mounted on outer wall of prefab unit on
top frame in upper corners of a shorter side walls,
covered on top with sheet metal cap for protection.
Connection between prefab units: rubber cable 5x6mm2,
7m long, with CEE plug and socket 5x32 A at each end, is
provided to each prefab unit- max.4 container in a row.
Inner distribution box, NYM-J cables of suitable
dimensions (6.0mm2, 2.5mm2, 0.75mm2),flush mounted.
Protection: protective current switch, automatic fuses.
Earthing: galvanized connector with a cross clip of
dimensions 60x60 mm welded on the bottom frame; 10
m of earthing conductor-flexible copper cable for earthing
in the field, is provided to each prefab unit as on request.
TECHNICAL SPECIFICATIONS