Sei sulla pagina 1di 8

Oildyne 108 Series Hydraulic

Power Units
Pressures to 241 bar (3500 psi)
Flows to 2.8 lpm ( 3/4 gpm)

3
Catalog HY22-1121/US Hydraulic Power Units
Features 108 Series

Typical applications
Positioning
• Hydraulic door operators
• Conveyor belt tensioners
• Medical chairs, beds, and equipment

Recreational Vehicles
• Leveling
• Slideouts
• Tent Trailers

Clamping
• Tool fixtures and jigs
• Hydraulic brakes
• Crimping tools
• Arbor presses
• Truck restraints

Cycling
• Garbage compactors
• Valve operators
• Press controls
• Packing equipment
• Indexing tables

Lifting
• Handicap lifts
• Scissor lift tables
• Pallet movers

108 Series Self-contained


Hydraulic Power Units
Our compact 108 Series power units let you put the function circuits with external valving.
power where you need it. They’re completely self-con-
tained with an AC or DC motor, gear pump, reservoir, Bi-directional, reversible units operate double-acting
internal valving, load hold checks and relief valves. cylinders and two-way motors.
The 108 Series models are designed for intermittent We’d like to work with you on your special hydraulic
service and come in four standard pump sizes which applications. Our people know small hydraulics. We
produce flows of .0098, .0187, .0246, and .0321 cubic know how to design them, how to make them and
inches per revolution. Locking check valves are avail- how to apply them. Therefore, we can offer you a
able in all models. Performance will vary with the type practical, economical solution to your fluid power
of fluid used. Several hydraulic circuits are available. problems.
108 Series units are available with single- or bi-di- Oildyne has pioneered top quality, compact hydraulic
rectional rotation. Single units are commonly used to components since 1955. We can provide standard
charge accumulators, power one-direction hydrau- products or custom design high pressure, space sav-
lic motors and cylinders, provide pilot flow to servo ing solutions to your specific needs.
valves, pressurize lube systems and supply multi-

4 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Technical Information 108 Series

Standard Product Ordering


108 SERIES Code
POWER UNIT
STANDARD ORDERING CODE

108

DN RV SETTING
108 POWER UNIT (Right Hand Port)
- includes relief Use 00 for Single Dir.
valve(s) In multiples of 100 psi
Examples
MOTOR CODE 04 = 400 psi
AE 12 vdc Permanent Magnet 12 = 1200 psi
AM 12 vdc Series Wound 29 = 2900 psi
BE 24 vdc Permanent Magnet
BI 24 vdc Series Wound UP RV SETTING
HA 115 vac, 1 phase, Open (Left Hand Port)
HD 230 vac, 1 phase, Open In multiples of 100 psi
IA 36 vdc Permanent Magnet Examples
04 = 400 psi
PUMP TYPE 12 = 1200 psi
S Standard 29 = 2900 psi
C Cold Temp

MOUNTING
PUMP SIZE V Vertical (motor up)
10 .0098 CIPR H Horizontal
19 .0187 CIPR
25 .0249 CIPR
32 .0321 CIPR PORTS
1 7/16-20 (SAE -4)
2 7/16-24 (Inv. Flare)
RESERVOIR
3 1/8" Pipe (NPSF)
A 26 cu. in. (13 cu. in. usable)
4 1/8" Pipe (BSPP)
B 46 cu. in. (23 cu. in. usable)
C 46 cu. in. (26 cu. in. usable) CIRCUIT TYPE
D Alternate orientation version of C NN Single direction
F 122 cu. in. (82 cu. in. usable) WW Single direction with check
G 69 cu. in. (46 cu. in. usable) RR Reversible
H 1/2 gallon usable LL Reversible locking
I 1 gallon usable RB Reversible with Back Pressure
J 1-1/2 gallon usable LB Reversible locking with Back Pressure
P 1/4 gal. usable (plastic)
Each Solenoid Valve option below
Q 1/2 gal. usable (plastic)
includes the WW circuit:
R 1 gal. usable (plastic)
S1 12 vdc, Normally Closed
S 3/4 gal. usable (plastic)
S2 24 vdc, Normally Closed
NOTES: C and D reservoirs S3 120 vac, Normally Closed
are available as Vertical S4 240 vac, Normally Closed
Mount ONLY. A reservoir with S5 12 vdc, Normally Open
pump 32 is available ONLY as S6 24 vdc, Normally Open
S7 120 vac, Normally Open
vertical mount.
S8 240 vac, Normally Open
ORDERING CODE INSTRUCTIONS
Select the model code needed based on catalog information. All boxes above must be filled in before Oildyne can process the
order. If the power unit is a single direction unit use '00' for the DN (Right Hand) relief valve box.

Hydraulic Fluid Temperature Range


ATF, OD18, or other clean hydraulic oil with a viscos- Normal operating range is +20°F to +140°F. Please
ity of 150 to 300 SUS at 38°C (100°F) is acceptable. review your application with the factory for uses be-
If another type of fluid is needed, please consult the low -7°C and over +60°C (+20°F and over +140°F).
factory.

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE


FOR POWER UNIT CONFIGURATIONS OTHER THAN THOSE SHOWN PLEASE CONSULT OILDYNE.

5 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Technical Information 108 Series

12/24 V DC Permanent Magnet Motor • Code AE • BE


Motor Type: AE and BE Wiring Diagram: AE • BE .100 Pump (.0098 cipr)
For intermittent duty cycles.
DPDT CENTER
.82 with AE / BE Motor 25
(50)

Output Flow - lpm (cipm)


OFF TOGGLE SWITCH -12 VDC SUPPLY (AE)
-24 VDC SUPPLY (BE)

Current - Amps
+12 VDC SUPPLY (AE) .66 20
+24 VDC SUPPLY (BE) (40)
Flow
LEFT HAND RIGHT HAND
PORT PORT .49 Current 15
(30) @ 12 VDC
GREEN OR BLUE OR
ORANGE BLACK .33
MOTOR LEAD MOTOR LEAD (20) 10

.16 5
(10)
Current
MOTOR @ 24 VDC
0 0
0 34 69 103 138 172 207
DPDT CENTER OFF TOGGLE (500) (1000) (1500) (2000) (2500) (3000)
SWITCH USABLE UP TO 20 AMPS
@ 12 VDC Pressure - bar (psi)

12/24 V DC Series Wound Motor • Code AM • BI


Motor Type: AM and BI Wiring Diagram: AM • BI .100 Pump (.0098 cipr)
For intermittent duty cycles. 1.6 with AM / BI Motor 60
+12 VDC SUPPLY (AM) -12 VDC SUPPLY (AM) (100)

Output Flow - lpm (cipm)


+24 VDC SUPPLY (BI) -24 VDC SUPPLY (BI)
SPDT
Flow

Current - Amps
CENTER OFF 1.3 48
TOGGLE SWITCH (80)
Current
LEFT HAND RIGHT HAND @ 12 VDC
PORT PORT .98 36
(60)
SOL 1 SOL
2 SWITCH
SWITCH
.66 24
(40)

SOL 1 SWITCH SOL 2 SWITCH


CONTACTS CONTACTS .33 12
(20) Current
@ 24 VDC
BLUE GREEN
MOTOR LEAD MOTOR LEAD 0 0
BLACK 0 34 69 103 138 172 207 241
MOTOR LEAD (500) (1000) (1500) (2000) (2500) (3000) (3500)
NOTES: AM MOTOR HAS 100 AMP
THERMAL BREAKER; MOTOR
Pressure - bar (psi)
BI MOTOR HAS 50 AMP
THERMAL BREAKER.

115/230 V AC Capacitor Start Motor • Code HA • HD


Motor Type: HA and HD .100 Pump (.0098 cipr)
Dual voltage 1/3 HP, 60/50 hz, .82 with HA / HD Motor
Wiring Diagram: HA (50)
5
Output Flow - lpm (cipm)

3450/2850 rpm, intermittent B


2 3
duty, single phase, open frame. R RELAY Current
O @ 115 VAC
Current - Amps

Capacitor and relay included. BLUE 4 .66 4


W (40)
WHITE N L-2
BLACK
115 VOLTAGE GREEN/YELLOW 161-193 MFD/125V Flow
CONNECTION MOTOR .49
RED 3
YELLOW (30)
ORANGE L-1
7 AMP
TO REVERSE, INTERCHANGE .33 2
RED AND BLACK LEADS (20) Current
@ 230 VAC

Wiring Diagram: HD B
R
.16 1
2 3 (10)
O RELAY
WHITE W 4
BLACK N
L-2 0 0
GREEN/YELLOW
230 VOLTAGE BLUE 161-193 MFD/230V 0 34 69 103 138 172 207
CONNECTION MOTOR (500) (1000) (1500) (2000) (2500) (3000)
ORANGE
RED
YELLOW
Pressure - bar (psi)
L-1
3 AMP
Note: 50 hz performance is 83% of curves shown.

6 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Technical Information 108 Series

Performance data based on ATF @ 21°C ( 70°F)

.190 Pump (.0187 cipr) .250 Pump (.0246 cipr) .327 Pump (.0321 cipr)
1.2 with AE / BE Motor 1.6 with AE / BE Motor 2.5 with AE / BE Motor 50
50 50 (150)
(75) (100)

Output Flow - lpm (cipm)


Output Flow - lpm (cipm)

Output Flow - lpm (cipm)


Flow

Current - Amps
Current - Amps

Current - Amps
.98 1.3 2.0 40
(60) 40 (80) 40 (120)
Current
Flow Current Current Flow @ 12 VDC
@ 12 VDC @ 12 VDC
.74 .98 1.5
30 30 (90) 30
(45) (60)

.49 .66 .98 20


(30) 20 (40) 20 (60)

Current
.25 .33 .49 @ 24 VDC
10 10 10
(15) Current (20) Current (30)
@ 24 VDC @ 24 VDC

0 0 0 0 0 0
0 34 69 103 138 172 207 0 34 69 103 138 172 207 0 34 69 103 138
(500) (1000) (1500) (2000) (2500) (3000) (500) (1000) (1500) (2000) (2500) (3000) (500) (1000) (1500) (2000)
Pressure - bar (psi) Pressure - bar (psi) Pressure - bar (psi)

.190 Pump (.0187 cipr) .250 Pump (.0246 cipr) .327 Pump (.0321 cipr)
2.5 with AM / BI Motor 75 3.3 with AM / BI Motor 100 4.1 with AM / BI Motor 100
(150) (200) (250)

Output Flow - lpm (cipm)


Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

Flow
Flow

Current - Amps
Current - Amps

Current - Amps
2.0 Flow 2.6 3.3
(120) 60 80 (200) 80
(160)
Current
@ 12 VDC
1.5 45 2.0 2.5 Current 60
(90) Current 60 (150) @ 12 VDC
(120)
@ 12 VDC

.98 1.3 1.6 40


(60) 30 40 (100)
(80)

.49 .66 .82 Current 20


(30) 15 20 (50) @ 24 VDC
Current (40) Current
@ 24 VDC @ 24 VDC
0 0 0 0
0 0
0 34 69 103 138 172 207 241 0 34 69 103 138 172 207 0 34 69 103 138 172
(500) (1000) (1500) (2000) (2500) (3000) (3500) (500) (1000) (1500) (2000) (2500) (3000) (500) (1000) (1500) (2000) (2500)
Pressure - bar (psi) Pressure - bar (psi) Pressure - bar (psi)

.190 Pump (.0187 cipr) .250 Pump (.0246 cipr) .327 Pump (.0321 cipr)
1.6 with HA / HD Motor 10 1.6 with HA / HD Motor 10 2.0 with HA / HD Motor 6
(100) (100) (125)
Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

Flow
Flow
Current - Amps

Current - Amps

Current - Amps

1.3 8 1.3 8 1.6


(80) (80) (100) 5

Flow
.98 .98 Current
6 6 1.3 @ 115 VAC 4
(60) (60) (75)

Current
.66 Current .66 @ 115 VAC .82
(40) 4 (40) 4 3
@ 115 VAC (50)

Current
.33 2 .33 2 .41 @ 230 VAC
(20) Current (20) (25) 2
@ 230 VAC Current
@ 230 VAC
0 0 0 0 0 1
0 34 69 103 138 172 207 0 34 69 103 138 172 207 0 21 41 62 83 103 124
(500) (1000) (1500) (2000) (2500) (3000) (500) (1000) (1500) (2000) (2500) (3000) (300) (600) (900) (1200) (1500) (1800)
Pressure - bar (psi) Pressure - bar (psi) Pressure - bar (psi)
Note: Performance data is for reference only.

7 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Circuits 108 Series

UP DN
UP DN
TRV

RV RV

“WW” CIRCUIT “NN” CIRCUIT

Thermal Relief Valves—


UP Why?
The thermal relief valve’s (TRV) purpose is to allow a
bleed off of built up pressure due to thermal expan-
TRV
sion of the fluid or to act as a (limited) shock load pro-
tection, should a cylinder in the system get bumped.

The thermal relief valve is included in circuits using


a pilot operated check valve. The single direction
units get one; the reversing units get two. It is located
RV between the check valve and the 108 Series pump
outlet port. It is a fixed relief valve with a pressure
setting approximately 100-140 bar (1500-2000 psi)
above the system relief valve pressure.

“S*” CIRCUIT

8 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Circuits 108 Series

UP DN
UP DN
BACK PRESSURE CIRCUIT

HPRV LPRV HPRV LPRV

“RR” CIRCUIT “RB” CIRCUIT

UP DN
TRV TRV
UP DN

TRV TRV

BACK PRESSURE CIRCUIT

HPRV LPRV HPRV LPRV

“LL” CIRCUIT “LB” CIRCUIT

Back Pressure Circuits—


Why?
The basic reversible circuit is essentially a closed loop. oil to return to the reservoir through a special shuttle
The oil returning from the system is fed back into the spool, before it reaches the pump. Full relief valve
pump inlet. When a cylinder is being retracted more pressure is then available to retract the cylinder, also
oil is being returned to the power unit than is leaving preventing a pressure switch from tripping before the
it due to the rod volume. This results in the DN side full retract position is achieved.
relief valve cracking open allowing the rod volume of oil Recommended uses:
to go back to the tank. The larger the rod volume the • In systems where work is being done on the
more open the relief valve will be. In many applications retract stroke
this is not a problem. However, if work is being done • Where a pressure switch is used to signal the full
retract position
on the retract stroke, or if a pressure switch is used to
• In systems requiring a faster retract than extend
signal the cylinder is fully retracted, the back pressure speed
circuit is required. This circuit allows the rod volume of

9 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA
Catalog HY22-1121/US Hydraulic Power Units
Dimensions 108 Series

Overall Dimensions
FRONT VIEW SIDE VIEW BACK VIEW
112.8
A (4.44)

STANDARD RESERVOIR
ORIENTATION IS SHOWN
ALTERNATE ORIENTATION
WOULD HAVE FILLER CAP ON
LEFT SIDE (IN FRONT VIEW) B

PORT SIZE SEE CODING


C
THIRD ANGLE
RESERVOIR
FILLER CAP PROJECTION
30.7
(1.21)

MAX MAX 85.3


(3.36)
MIN MIN 46 CU IN
RESERVOIR
2 MOUNTING HOLES
3/8-16 UNC-2B X 7/16 DP.
29.2 29.4
(1.15) 149.4 (1.16)
29.2 (5.88) 29.4
(1.15) (1.16)
97.3 64.9
(3.83) (2.55)

With 75.4±0.8
(Ø2.97±.03)
Solenoid 12 VDC MOTOR

Motor Dimensions ±.1.3 (±.050)


7/16-20 PRESSURE PORT 126.2
(4.97)
A B C
UNUSED PRESSURE PORT PLUG AE/BE 75.4 126.2 241.3
RESERVOIR FILLER CAP SOLENOID VALVE
(2.97) (4.97) (9.50)
AM/BI 95.8 151.4 266.4
30.7 (3.77) (5.96) (10.49)
(1.21)
IA 75.4 128.8 244.1
(2.97) (5.07) (9.61)
83.8±1.5
HA/HD 100.1 161.0 276.4
(3.30±.06) (3.94) (6.34) (10.88)

1.27±0.8
29.2
(1.15)
29.2
(1.15) 141.7±1.5 (.05±.03) Note: All dimensions in mm (inches).
(5.58±.06)

Reservoir Dimensions
162.1
(6.38)
Note: refer to page 17 for information on the P, Q, R and S reservoirs.

80.3
(3.16)
123.8
(4.88)
149.4 8
161.0
(5.88) (6.34)
93.9
(Ø3.70)
HDPE

“A” RESERVOIR
2

28 CU. IN. (13 CU. IN. USABLE) ALUMINUM


91.2
(Ø3.59) (459 CC: 213 CC USABLE)
93.9
(Ø3.70)

“B” RESERVOIR 101.6


46 CU. IN. (23 CU. IN. USABLE) ALUMINUM (Ø4.00)
(754 CC: 377 CC USABLE)
85.3 "G" RESERVOIR
(3.36)
#3-69 CU. IN. (46 CU. IN. USABLE) EXTRUDED ALUMINUM
(1130 CC: 754 USABLE)

“C” RESERVOIR
46 CU. IN. (26 CU. IN. USABLE)
HIGH DENSITY POLYETHYLENE WITH UV ADDITIVE STD.
(754 CC: 426 CC USABLE)
266.7 175.3 H I J
(10.50) (6-7/8) 1/2 GAL 1.0 GAL 1.5 GAL 142.3
(2 Liter) (4 Liter) (5.6 Liter) (5.60)

101.6
(Ø4.00)

184.6
"H,H,
I , I,J"JRESERVOIR
RESERVOIR -STEEL
STEEL (7.27)
311.7
(12.27)
413.3
"F" RESERVOIR (16.27)
122 CU. IN. (82 CU. IN. USABLE) STEEL
(2000 CC: 1344 CC USABLE)

10 Parker Hannifin Corporation


Oildyne Division
Minneapolis, MN 55428  USA