Upright Microscope

Accessories
Contents
Ni-E (Focusing stage type) Ni-E (Focusing nosepiece type)
Brightfield set ………………1 Multi-color fluorescent imaging set………………5

Epi-fluorescence set ………………2 Photoactivation imaging set ………………6

DIC (Differential Interference Contrast) set ………………3 Simultaneous multichannel imaging set ………………7

Epi-fluorescence and DIC set ………………4

Ni-U Ni-U
Brightfield set ………………8 Phase contrast set ………………12

Epi-fluorescence set ………………9 Motorized module ………………13

DIC (Differential Interference Contrast) set ………………10 Photoactivation imaging set ………………14

Epi-fluorescence and DIC set ………………11 Simultaneous multichannel imaging set ………………15

Ci-E/Ci-L/Ci-S
Brightfield set (Ci-E) ………………16 Tube/Port/TV-Tube/TV Adapter …………………21

Brightfield set (Ci-L/Ci-S) ………………17 Eyepiece/Substage/Stage …………………22

Epi-fluorescence set (Ci-E) ………………18 Condenser/Intermediate module/Other accessory …………………23

Epi-fluorescence set (Ci-L/Ci-S) ………………19 Teaching accessory …………………24

Phase contrast set ………………20


Ni-E brightfield set 1
• Ni-E (focusing stage type, motorized) set for brightfield observation
• Enables 2x to 100x observation by switching objectives with simple push-button operation.
• Two cameras can be mounted simultaneously.
Ni-E (Focusing stage type)

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶_____ MBD92100_______NIE-CAM Contact Arm
____❷_____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
____❸ ____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube

_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42070______C-Mount Adapter 0.7X
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❹ ____ MBP98405_______NI-N7-E Motorized Septuple Nosepiece
______________________________________Objectives
____❺ ____ MBD93010_______NI-SSR Substage for Rotatable/Motorized Stage
____❻ ____ MBC91010_______NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder ❷ ❺

____❼_____ MBL99800________NI-CUD-E Motorized Universal Condenser Dry


____❽ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1 Position
____❾ ____ MBE95205_______NI-LH Precentered Lamphouse
_____________ MBF95400_______NI-CTLA Control Box A
❻ ❾
____❿ ____ MQA21020______DS-L3 DS Camera Control Unit ❸

_____________ MQF52055_______AC Adapter 2


____‐_________________________________USB Cable

Option_______
___ ⓫ ____ MBC96100_______NI-S-E Motorized XY Stage*1 ❹ ❼ ❽

*2
____________ MBC96110_______NI-SA Motorized XY Stage Adapter
___ ⓬ ____ MBF95130_______NI-SJ Joystick for Motorized Stage*2
___ ⓭ ____ MBF95110_______NI-ERG NI Ergo Controller*2*3
___ ⓮ ____ MBN98800_______NI-ND-E Motorized ND Filter
___ ⓯ ____ MBF95420_______NIE-CB Connector Box*4
⓫ ⓬
*1 NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder can be used as an alternative. ⓭ ⓮ ⓯
*2 For use with NI-S-E Motorized XY Stage
*3 NI-SJ Joystick for Motorized Stage can be used as an alternative.
*4 Required when using NI-S-E Motorized XY Stage or NI-ND-E Motorized ND Filter.
Ni-E epi-fluorescence set 2
• Ni-E (focusing stage type, motorized) set for epi-fluorescence observation
• Filter cubes can be switched with a simple push-button operation.
• Motorized condenser attachment enables 2x to 100x brightfield observation.
Ni-E (Focusing stage type) • Two cameras can be mounted simultaneously.

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92100_______NIE-CAM Contact Arm
____❷ ____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
____❸_____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube ❶
_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
❺ ❽
____❹ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret

____❺ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber ❸ ❻
_____________ MBF72311_______C-HGFIB HG100W Adapter R ❾
____❻ ____ MBP98405_______NI-N7-E Motorized Septuple Nosepiece
____‐_________________________________Objectives
____❼ ____ MBD93010_______NI-SSR Substage for Rotatable /Motorized Stage ❿
____❽ ____ MBC91010_______NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder

____❾ ____ MBL99800________NI-CUD-E Motorized Universal Condenser Dry ❹

____❿ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position*1 Option___________________________


_____________ MBE95205_______NI-LH Precentered Lamphouse ⓫
⓫_____MBN71930_______ D-FB Excitation Balancer*2
_____________ MBF95400_______NI-CTLA Control Box A
⓬_____MBH70210_______ D-C PH-1 PH Module*3
_____________ MQA21020______DS-L3 DS Camera Control Unit ⓯
⓭_____MBH70220_______ D-C PH-2 PH Module*3
_____________ MQF52055_______AC Adapter 2
⓮_____MBH70230_______ D-C PH-3 PH Module*3
‐____________ -_______________________USB Cable
⓯_____MBH70250_______ D-C DF Dark Field Module*4
⓬ ⓭ ⓮
*1 Required when using 2x and 4x objectives
*2 For use in combination with multi-band filter cube
*3 For use in combination with phase contrast objectives
*4 Required for darkfield observation
Ni-E DIC (Differential Interference Contrast) set 3
• Ni-E (focusing stage type, motorized) set for DIC observation
• Simple push-button operation simultaneously switches objectives and optical modules within the condenser.
• Motorized condenser attachment enables 2x to 100x brightfield observation.
Ni-E (Focusing stage type) • Two cameras can be mounted simultaneously.

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92100_______NIE-CAM Contact Arm
____❷ ____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube

____❸_____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube ❹ ❺ ❻ ❼

_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube


_____________ MQD42070______C-Mount Adapter 0.7X
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❹ ____ MBP98325_______NI-ND6-E Motorized DIC Sextuple Nosepiece
____❺ ____ -_______________________D-C DIC Sliders ❷
❽ ❾
____❻ ____ MBN74920_______D-DA Analyzer Slider for DIC
____❼ ____ MBN74960_______D-LP Lambda Plate
____‐_________________________________Objectives
____❽ ____ MBD93010_______NI-SSR Substage for Rotatable /Motorized Stage
____❾ ____ MBC91010_______NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder ❸
____❿ ____ MBL99800________NI-CUD-E Motorized Universal Condenser Dry ❿
*1*2
____⓫ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position
____⓬ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position*1*3
____⓭ ____ MBH72300_______D-C DIC N1 DRY DIC Module
⓫ ⓬ ⓭ ⓮
____⓮ ____ MBH72310_______D-C DIC N2 DRY DIC Module ⓯
____⓯ ____ MBN74940_______D-DP DIC Rotatable Polarizer Option___________________________
_____________ MBE95205_______NI-LH Precentered Lamphouse
⓰_____MBH70210_______ D-C PH-1 PH Module*4
_____________ MBF95400_______NI-CTLA Control Box A ⓳
⓱_____MBH70220_______ D-C PH-2 PH Module*4
_____________ MQA21020______DS-L3 DS Camera Control Unit
⓲_____MBH70230_______ D-C PH-3 PH Module*4
_____________ MQF52055_______AC Adapter 2
⓳_____MBH70250_______ D-C DF Dark Field Module*5 ⓰ ⓱ ⓲
____‐_________________________________USB Cable
*1 Required when using 2x and 4x objectives
*2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
*4 For use in combination with phase contrast objectives
*5 Required for darkfield observation
Ni-E epi-fluorescence and DIC set 4-1
• Ni-E (focusing stage type, motorized) set for epi-fluorescence and DIC observation
• Filter cubes can be switched with simple push-button operation.
• Simple push-button operation simultaneously switches objectives and
Ni-E (Focusing stage type)    optical modules within the condenser.

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92100_______NIE-CAM Contact Arm
____❷ ____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
____❸_____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube

_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❹ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret
____❺ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
____❻ ____ MEN51980_______TI-A DIC Analyzer Cube ❺
_____________ -_______________________FL Filter Cubes ❷
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
____❼ ____ MBP98325_______NI-ND6-E Motorized DIC Sextuple Nosepiece
____❽ ____ MBN74960_______D-LP Lambda Plate ❸ ❻

____❾ ____ -_______________________D-C DIC Sliders

❼ ❽ ❾
Ni-E epi-fluorescence and DIC set 4-2
Ni-E (Focusing stage type)

____‐_________________________________Objectives
____❿ ____ MBD93010_______NI-SSR Substage for Rotatable /Motorized Stage
____⓫ ____ MBC91010_______NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder
____⓬ ____ MBL99800________NI-CUD-E Motorized Universal Condenser Dry
____⓭_____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position*1*2

____⓮ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position*1*3
____⓯ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓰_____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓱ ____ MBN74940_______D-DP DIC Rotatable Polarizer

_____________ MBE95205_______NI-LH Precentered Lamphouse
_____________ MBF95400_______NI-CTLA Control Box A
⓫ 
_____________ MQA21020______DS-L3 DS Camera Control Unit
_____________ MQF52055_______AC Adapter 2

____‐_________________________________USB Cable
⓴  

Option___________________________
*4
⓲_____MBN91920_______ NI-FA FL/DIC Analyzer
⓳_____MBN71930_______ D-FB Excitation Balancer*5
⓴_____MBH70210_______ D-C PH-1 PH Module*6
_____MBH70220_______ D-C PH-2 PH Module*6
_____MBH70230_______ D-C PH-3 PH Module*6
⓭ ⓮ ⓯ ⓰ ⓱ _____MBH70250_______ D-C DF Dark Field Module*7

*1 Required when using 2x and 4x objectives


*2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
*4 Required for epi-fluorescence DIC observation; should be manually
     inserted into optical path
*5 For use in combination with multi-band filter cube
*6 For use in combination with phase contrast objectives
*7 Required for darkfield observation
Ni-E multi-color fluorescent imaging set 5-1
• Ni-E (focusing nosepiece type, motorized) set for multi-color imaging
• Motorized excitation/barrier filter wheels enable multi-color fluorescence imaging.
Ni-E (Focusing nosepiece type)

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92200_______NI-FNA Focusing Nosepiece Sub Arm
____❷_____ MXB22378_______NI-AMSS Arm Spacer 49mm
____❸ ____ MBD92100_______NIE-CAM Contact Arm ❶
____❹ ____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
____❺_____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube
_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.) ❻
____❻ ____ MBE94620_______NI-BAW-E Motorized Barrier Filter Wheel ❷

____❼ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret


____❽ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
____❾ ____ MEN51980_______TI-A DIC Analyzer Cube ❸

____❿ ____ MEN71956_______A1-FN1-IR Analyzer Block IR
____⓫ ____ MBE94610_______NI-EXW-E Motorized Excitation Filter Wheel
____⓬ ____ MBE96000_______NI-SH-E Motorized Shutter
_____________ MBE96920_______NI-SHCS Motorized Shutter Cable Short
_____________ MBE96905_______TI-SHAEP-I Motorized Shutter Adapter for Inverted Epi-FL

_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight ❹
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
❾ ❿
____⓭ ____ MBP70100_______FN-S2N 2 Place Sliding Nosepiece ⓫

⓬ ⓭
Ni-E multi-color fluorescent imaging set 5-2
Ni-E (Focusing nosepiece type)

____‐_________________________________Objectives
_____________ -_______________________D-C DIC Sliders
____⓮_____ MBD93030_______NI-SSF Substage for Focusing Nosepiece
_____________ MBC96100_______NI-S-E Motorized XY Stage
_____________ MBC96110_______NI-SA Motorized XY Stage Adapter
_____________ MBF95130_______NI-SJ Joystick for Motorized Stage ⓮
_____________ MXB22406_______NI-SH-D Dish Holder
____⓯ ____ MBL70100________FN-C LWD Condenser
____⓰ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓱ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓲ ____ MBH72100_______FN-PT4X 4X Support Lens

____⓳ ____ MBN91930_______NI-PT Polarizer Turret

____⓴ ____ MBN71946_______FN-P Polarizer
____ ____ MBN71960_______FN-IRP IR Polarizer
_____________ MBY10037_______NI-IRLH Precentered IR Lamphouse
_____________ MBF95400_______NI-CTLA Control Box A 
 
_____________ MBF95420_______NIE-CB Connector Box ⓰ ⓱

_____________ MQA21020______DS-L3 DS Camera Control Unit


Option___________________________
_____________ MQF52055_______AC Adapter 2
 ____MXB22379_______ NI-AMSL Arm Spacer 74mm
____‐_________________________________USB Cable
⓲  ____MBP70110_______ FN-MN-H CFI 75 Holder
 ____MBH76225_______ D-C DIC 25XI DIC Slider
 ____MRD77220_______ CFI75 Apochromat 25XW MP
_________MBC74001_______ FN-3PS2 FN1 Standard Stage
_________MBC94100_______ NI-3PSA Adapter for FN1 Standard Stage
⓳ ⓴  _________MBN98800_______ NI-ND-E Motorized ND Filter
_________MBE96900_______ NI-SHAEP-U Motorized Shutter Adapter for Upright Epi-FL
Ni-E photoactivation imaging set 6-1
• Ni-E (focusing nosepiece type, motorized) set for photoactivation imaging.
• Enables photoactivation of a cell or a living organism, and image acquisition of its reaction.

Ni-E (Focusing nosepiece type)

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92200_______NI-FNA Focusing Nosepiece Sub Arm
____❷ ____ MXB22378_______NI-AMSS Arm Spacer 49mm
____❸ ____ MBD92100_______NIE-CAM Contact Arm
_____________ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
_____________ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube
_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.) ❶

____❹ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret (2 Units)
____❺ ____ MBE94800_______NI-PAU Ni Photoactivation Unit
____❻ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
____❼ ____ MEN51980_______TI-A DIC Analyzer Cube
____❽_____ MEN71956_______A1-FN1-IR Analyzer Block IR
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight ❷ ❺
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
____❾ ____ MBP70100_______FN-S2N 2 Place Sliding Nosepiece


❼ ❽ ❾
Ni-E photoactivation imaging set 6-2
Ni-E (Focusing nosepiece type)

____‐_________________________________Objectives
_____________ -_______________________D-C DIC Sliders
____❿ ____ MBD93030_______NI-SSF Substage for Focusing Nosepiece
_____________ MBC96100_______NI-S-E Motorized XY Stage
_____________ MBC96110_______NI-SA Motorized XY Stage Adapter

_____________ MBF95130_______NI-SJ Joystick for Motorized Stage

_____________ MXB22406_______NI-SH-D Dish Holder
____⓫ ____ MBL70100________FN-C LWD Condenser
____⓬ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓭ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓮ ____ MBH72100_______FN-PT4X 4X Support Lens ⓬ ⓭

____⓯ ____ MBN91930_______NI-PT Polarizer Turret
____⓰ ____ MBN71946_______FN-P Polarizer
____⓱ ____ MBN71960_______FN-IRP IR Polarizer

_____________ MBY10037_______NI-IRLH Precentered IR Lamphouse
_____________ MBF95400_______NI-CTLA Control Box A
_____________ MBF95420_______NIE-CB Connector Box
_____________ MQA21020______DS-L3 DS Camera Control Unit ⓯
_____________ MQF52055_______AC Adapter 2 ⓳ ⓴ 
____‐_________________________________USB Cable
______________________________________ Option___________________________
⓰ ⓱
⓲ ____MXB22379_______ NI-AMSL Arm Spacer 74mm
⓳ ____MBP70110_______ FN-MN-H CFI 75 Holder
⓴ ____MBH76225_______ D-C DIC 25XI DIC Slider
 ____MRD77220_______ CFI75 Apochromat 25XW MP
_________MBC74001_______ FN-3PS2 FN1 Standard Stage
_________MBC94100_______ NI-3PSA Adapter for FN1 Standard Stage
Ni-E simultaneous multichannel imaging set 7-1
• Ni-E (focusing nosepiece type, motorized) set for multi-channel, simultaneous imaging.
• Enables simultaneous acquisition of fluorescence images in two different wavelengths.

Ni-E (Focusing nosepiece type)

_____________ MBA91000_______ECLIPSE Ni-E Main Body


____❶ ____ MBD92200_______NI-FNA Focusing Nosepiece Sub Arm
____❷ ____ MXB22378_______NI-AMSS Arm Spacer 49mm
____❸ ____ MBD92100_______NIE-CAM Contact Arm ❶
____❹ ____ MBB94510_______NI-TT-E Motorized Quadrocular Tilting Tube
____❺_____ MBB96710_______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube
_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube
_____________ MQD42000______C-Mount TV Adapter A ❼
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.)

____❻ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret (2 Units)
____❼ ____ MBE94200_______NI-BPU Back Port Unit
____❽ ____ MXA22128_______C-FL2 Blank Cube ❻
❽ ❾ ❿
____❾ ____ MBE49310_______C-FLM Mirror Cube
____❿ ____ MBE49300_______C-FLF FRET Cube ❸
____⓫ ____ MBB96900_______NI-RPS DSC Support Column
____⓬ ____ MBB96910_______NI-RPSAA DSC Adapter A (for the Andor iXon Series)
____⓭ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
____⓮ ____ MEN51980_______TI-A DIC Analyzer Cube
❹ ⓫ ⓬ ⓭
____⓯ ____ MEN71956_______A1-FN1-IR Analyzer Block IR
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
____⓰ ____ MBP70100_______FN-S2N 2 Place Sliding Nosepiece
⓮ ⓯ ⓰

Ni-E simultaneous multichannel imaging set 7-2
Ni-E (Focusing nosepiece type)

____‐_________________________________Objectives
_____________ -_______________________D-C DIC Sliders
____⓱ ____ MBD93030_______NI-SSF Substage for Focusing Nosepiece
_____________ MBC96100_______NI-S-E Motorized XY Stage
_____________ MBC96110_______NI-SA Motorized XY Stage Adapter
_____________ MBF95130_______NI-SJ Joystick for Motorized Stage ⓱
_____________ MXB22406_______NI-SH-D Dish Holder
____⓲ ____ MBL70100________FN-C LWD Condenser
____⓳ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓴ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____ ____ MBH72100_______FN-PT4X 4X Support Lens
⓲  
____ ____ MBN91930_______NI-PT Polarizer Turret
____ ____ MBN71946_______FN-P Polarizer
____ ____ MBN71960_______FN-IRP IR Polarizer
_____________ MBY10037_______NI-IRLH Precentered IR Lamphouse
_____________ MBF95400_______NI-CTLA Control Box A ⓳ ⓴
_____________ MBF95420_______NIE-CB Connector Box   
_____________ MQA21020______DS-L3 DS Camera Control Unit
_____________ MQF52055_______AC Adapter 2
Option___________________________
____‐_________________________________USB Cable
 ____MXB22379_______ NI-AMSL Arm Spacer 74mm

 ____MBB96920_______ NI-RPSAB DSC Adapter B (for the Roper Cascade Series)
 ____MBP70110_______ FN-MN-H CFI 75 Holder
 ____MBH76225_______ D-C DIC 25XI DIC Slider
 ____MRD77220_______ CFI75 Apochromat 25XW MP
_________MBC74001_______ FN-3PS2 FN1 Standard Stage
  
_________MBC94100_______ NI-3PSA Adapter for FN1 Standard Stage
Ni-U brightfield set 8
• Basic set for brightfield observation

_____________ MBA92010_______ECLIPSE Ni-U Main Body



____❶ ____ MBD92000_______NI-SAM Standard Arm
____❷_____ MBB93800_______C-TE2 Ergonomic Binocular Tube
____❸ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube ❸
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❹_____ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD ❶
____‐_________________________________Objectives
____❺ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
____❻ ____ MBD93000_______NI-SS Substage
____❼_____ MBD94000_______NI-CH Condenser Holder
____❽ ____ MBL71200________C-C Achromat Condenser NA 0.9
____❾ ____ MBE95205_______NI-LH Precentered Lamphouse ❹ ❺

Option___________________________
❿ ____MBB93110_______ C-TT Trinocular Tube T
⓫ ____MBB73520_______ Y-TV TV Tube
_________MQD42070______ C-Mount Adapter 0.7X ❻ ❼
❿ ⓫
_________MBP71325_______ C-N6A Sextuple Nosepiece with Analyzer Slot
⓬ ____MBB75380_______ C-TP Polarizer for First-order Red Compensation For First-order Red Compensation
*1*2
⓭ ____MBN91921_______ C-AS Analyzer Slider for First-oder Red Compensation
⓮ ____MBB75360_______ C-IA Analyzer Tube for First-order Red Compensation
⓯ ____MBB75370_______ C-SP Polarizer for Simple Polarization
❽ ⓬ ⓭ ⓮
⓰ ____MBN74925_______ D-SA Analyzer Slider for Simple Polarization*1*3 ❾
For Simple Polarization
⓱ ____MBB75350_______ C-ISA Analyzer Tube for Simple Polarization

*1 For use in combination with C-N6A Sextuple Nosepiece with Analyzer Slot.
*2 C-IA Analyzer Tube for First-order Red Compensation can be used as an alternative.
*3 C-ISA Analyzer Tube for Simple Polarization can be used as an alternative. ⓯ ⓰ ⓱
Ni-U epi-fluorescence set 9
• Ni-U set for epi-fluorescence observation

_____________ MBA92010_______ECLIPSE Ni-U Main Body


_____________ MBD92000_______NI-SAM Standard Arm
_____________ MBB93110_______C-TT Trinocular Tube T
_____________ MBB73520_______Y-TV TV Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.) ❷
____❶_____ MBE94500_______NI-FLT6 Epi-fluorescence Cube Turret ❸

____❷ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
____❸ ____ MBF72655_______C-HGFI HG Precentered Fiber Illumination Intensilight
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
____❹ ____ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD
____‐_________________________________Objectives ❻
❹ ❺
____❺ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
____❻_____ MBD93000_______NI-SS Substage
____❼ ____ MBD94000_______NI-CH Condenser Holder
____❽_____ MBL71200________C-C Achromat Condenser NA 0.9
_____________ MBE95205_______NI-LH Precentered Lamphouse

❼ ❽

Option_______________________
❾ ____MBN71930_______ D-FB Excitation Balancer*1

*1 For use in combination with multi-band filter cube



Ni-U DIC (Differential Interference Contrast) set 10
• Ni-U set for DIC observation

_____________ MBA92010_______ECLIPSE Ni-U Main Body


_____________ MBD92000_______NI-SAM Standard Arm
_____________ MBB93110_______C-TT Trinocular Tube T
_____________ MBB73520_______Y-TV TV Tube
_____________ MQD42070______C-Mount Adapter 0.7X ❶
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❶ ____ MBP73325_______D-ND6 DIC Sextuple Nosepiece
____❷ ____ MBN74920_______D-DA Analyzer Slider for DIC
❷ ❸ ❹
____❸ ____ MBN74960_______D-LP Lambda Plate
____❹ ____ -_______________________D-C DIC Sliders
____‐_________________________________Objectives
____❺ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
____❻ ____ MBD93000_______NI-SS Substage
____❼ ____ MBD94000_______NI-CH Condenser Holder ❻

____❽_____ MBL99000________NI-CUD Universal Condenser Dry
____❾ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position*1*2
____❿ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position*1*3
____⓫ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓬ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓭ ____ MBN74940_______D-DP DIC Rotatable Polarizer
❼ ❾ ❿

_____________ MBE95205_______NI-LH Precentered Lamphouse

Option___________________________
⓮ ____MBH70210_______ D-C PH-1 PH Module*4 ⓬
⓱ ⓫
⓯ ____MBH70220_______ D-C PH-2 PH Module*4
⓰ ____MBH70230_______ D-C PH-3 PH Module*4
⓱ ____MBH70250_______ D-C DF Dark Field Module*5
⓮ ⓯ ⓰
*1 Required when using 2x and 4x objectives
*2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
*4 For use in combination with phase contrast objectives
*5 Required for darkfield observation
Ni-U epi-fluorescence and DIC set 11
• Ni-U set for epi-fluorescence and DIC observation

_____________ MBA92010_______ECLIPSE Ni-U Main Body


_____________ MBD92000_______NI-SAM Standard Arm
_____________ MBB93110_______C-TT Trinocular Tube T
_____________ MBB73520_______Y-TV TV Tube
_____________ MQD42000______C-Mount TV Adapter A ❷
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.) ❹
____❶ ____ MBE94500_______NI-FLT6 Epi-fluorescence Cube Turret ❶
____❷ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
____❸ ____ MBN91920_______NI-FA FL/DIC Analyzer
_____________ -_______________________FL Filter Cubes
____❹ ____ MBF72655_______C-HGFI HG Precentered Fiber Illumination Intensilight ❸
_____________ MBF71610_______C-HGFIF15 HG Fiber

_____________ MBF72311_______C-HGFIB HG100W Adapter R
____❺ ____ MBP73325_______D-ND6 DIC Sextuple Nosepiece
____❻ ____ MBN74960_______D-LP Lambda Plate ❻ ❼
⓮ ⓯ ⓰ ⓱

____❼ ____ -_______________________D-C DIC Sliders
____‐_________________________________Objectives Option___________________________
_____________ MBC91110_______C-SR2S Right Handle Stage with 2SHolder ⓮ ____MBN71930_______ D-FB Excitation Balancer*4
_____________ MBD93000_______NI-SS Substage ⓯ ____MBH70210_______ D-C PH-1 PH Module*5
_____________ MBD94000_______NI-CH Condenser Holder ⓰ ____MBH70220_______ D-C PH-2 PH Module*5
____❽ ____ MBL99000________NI-CUD Universal Condenser Dry ❽ ⓱ ____MBH70230_______ D-C PH-3 PH Module*5
*1*2
____❾ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position ⓲ ____MBH70250_______ D-C DF Dark Field Module*6
*1*3
____❿ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position
❾ ❿
____⓫ ____ MBH72300_______D-C DIC N1 DRY DIC Module *1 Required when using 2x and 4x objectives
____⓬ ____ MBH72310_______D-C DIC N2 DRY DIC Module *2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
____⓭ ____ MBN74940_______D-DP DIC Rotatable Polarizer ⓫ ⓬ *4 For use in combination with multi-band filter cube
*5 For use in combination with phase contrast objectives
_____________ MBE95205_______NI-LH Precentered Lamphouse *6 Required for darkfield observation


Ni-U phase contrast set 12
• Ni-U set for phase contrast observation

_____________ MBA92010_______ECLIPSE Ni-U Main Body


____❶ ____ MBD92000_______NI-SAM Standard Arm
____❷ ____ MBB93110_______C-TT Trinocular Tube T
____❸ ____ MBB73520_______Y-TV TV Tube
_____________ MQD42070______C-Mount Adapter 0.7X
_____________ MAK30100_______CFI UW 10X Eyepiece (2 pcs.)
____❹_____ MAK85000_______C-CT Centering Telescope with UW Adapter
____❺ ____ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD
❶ ❷
____‐_________________________________Objectives
____❻ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
____❼_____ MBD93000_______NI-SS Substage
____❽ ____ MBD94000_______NI-CH Condenser Holder
____❾ ____ MBL73100________C-C Phase Contrast Turret Condenser
____❿ ____ MBE95205_______NI-LH Precentered Lamphouse ❸ ❹ ❺

❻ ❼ ❽ ❾ ❿
Ni-U motorized module 13
• Accessories for the Ni-U microscope, such as motorized epi-fluorescence cube turrets, motorized nosepieces
   and motorized shutters (including intelligent types).

____❶ ____ MBD92110_______NIU-CAM Contact Arm


____❷ ____ MBF95410_______NI-CTLB Control Box B
____❸ ____ MBF95120_______NI-SRCP Simple Remote Control Pad
____❹_____ MQA21020______DS-L3 DS Camera Control Unit
_____________ MQF52055_______AC Adapter 2
_____________ MXA22113_______C-CTC Camera Trigger Cable U3/L3
_____________ MEF51001________TI-100WRC 100W Lamphouse Remote Cable
____❺ ____ MBP98405_______NI-N7-E Motorized Septuple Nosepiece
____❻ ____ MBP99405_______NI-N7-I Intelligent Septuple Nosepiece

____❼ ____ MBP98325_______NI-ND6-E Motorized DIC Sextuple Nosepiece

____❽_____ MBP99325_______NI-ND6-I Intelligent DIC Sextuple Nosepiece
____❾_____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret
____❿ ____ MBE94400_______NI-FLT6-I Intelligent Epi-fluoresce Cube Turret
____⓫ ____ MBE96000_______NI-SH-E Motorized Shutter
_____________ MBE96930_______NI-SHCL Motorized Shutter Cable Long

_____________ MBE96900_______NI-SHAEP-U Motorized Shutter Adapter for Upright Epi-FL*1 ❹
_____________ MBE96910_______NI-SHADI Motorized Shutter Adapter for Dia-Illumination*2

*1 Required for attaching the NI-SH-E Motorized Shutter to the NI-FLEI EPI-Fluorescence Attachment.
*2 Required for attaching the NI-SH-E Motorized Shutter to the diascopic illumination unit.

❺ ❻ ❼ ❽


❾ ❿
Ni-U photoactivation imaging set 14-1
• Attaching the photoactivation unit to the Ni-U microscope also enables photoactivation imaging.

_____________ MBA92010_______ECLIPSE Ni-U Main Body


____❶ ____ MBD92110_______NIU-CAM Contact Arm
____❷ ____ MBB94521_______NI-TT Quadrocular Tilting Tube
____❸ ____ MBB96721_______NI-RPZ DSC Zooming Port for Quadrocular Tube
_____________ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube ❶

_____________ MQD42000______C-Mount TV Adapter A


_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.)
_____________ MBE94500_______NI-FLT6 Epi-fluorescence Cube Turret
_____________ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
____❹ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret
____❺ ____ MBE94800_______NI-PAU Ni Photoactivation Unit ❷ ❸
_____________ -_______________________FL Filter Cubes
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R
____❻_____ MBP98325_______NI-ND6-E Motorized DIC Sextuple Nosepiece
____❼ ____ MBN91920_______NI-FA FL/DIC Analyzer
❹ ❺
____❽ ____ MBN74960_______D-LP Lambda Plate
____❾ ____ -_______________________D-C DIC Sliders

❻ ❼ ❽ ❾
Ni-U photoactivation imaging set 14-2

____‐_________________________________Objectives
_____________ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
_____________ MBD93000_______NI-SS Substage
_____________ MBD94000_______NI-CH Condenser Holder
____❿ ____ MBL99000________NI-CUD Universal Condenser Dry
____⓫ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position*1*2
____⓬ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position*1*3 ❿
____⓭ ____ MBH72300_______D-C DIC N1 DRY DIC Module
____⓮ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓯ ____ MBN74940_______D-DP DIC Rotatable Polarizer ⓫ ⓬
____⓰ ____ MBF95410_______NI-CTLB Control Box B 
____⓱_____ MBF95120_______NI-SRCP Simple Remote Control Pad
_____________ MQA21020______DS-L3 DS Camera Control Unit
_____________ MQF52055_______AC Adapter 2 ⓭ ⓮ ⓴
⓲ ⓳
_____________ MXA22113_______C-CTC Camera Trigger Cable U3/L3
_____________ MEF51001________TI-100WRC 100W Lamphouse Remote Cable Option___________________________
_____________ MBE95205_______NI-LH Precentered Lamphouse ⓲ ____MBH70210_______ D-C PH-1 PH Module*4
⓳ ____MBH70220_______ D-C PH-2 PH Module*4
⓴ ____MBH70230_______ D-C PH-3 PH Module*4
⓯  ____MBH70250_______ D-C DF Dark Field Module*5

*1 Required when using 2x and 4x objectives


*2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
*4 For use in combination with phase contrast objectives
*5 Required for darkfield observation


Ni-U simultaneous multichannnel imaging set 15-1
• Attaching the back port unit to the Ni-U microscope also enables simultaneous multichannel imaging.

_____________ MBA92010_______ECLIPSE Ni-U Main Body


____❶ ____ MBD92110_______NIU-CAM Contact Arm
_____________ MBB93110_______C-TT Trinocular Tube T
_____________ MBB73520_______Y-TV TV Tube
_____________ MQD42000______C-Mount TV Adapter A
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.) ❶
____❷ ____ MBE94500_______NI-FLT6 Epi-fluorescence Cube Turret ❷

____❸ ____ MBE94200_______NI-BPU Back Port Unit


____❹ ____ MXA22128_______C-FL2 Blank Cube
____❺ ____ MBE49310_______C-FLM Mirror Cube ❸
____❻ ____ MBE49300_______C-FLF FRET Cube
____❼ ____ MBB96900_______NI-RPS DSC Support Column
____❽ ____ MBB96910_______NI-RPSAA DSC Adapter A (for the Andor iXon Series) ❼

____❾ ____ MBE94300_______NI-FLT6-E Motorized Epi-fluorescence Cube Turret ❹ ❺ ❻
____❿ ____ MBE94100_______NI-FLEI EPI-Fluorescence Attachment
_____________ -_______________________FL Filter Cubes
_____________ MBF72665_______C-HGFIE HG Precentered Fiber Illumination Intensilight
_____________ MBF72600_______C-HGFIE-C HG Controller
_____________ MBF71610_______C-HGFIF15 HG Fiber
_____________ MBF72311_______C-HGFIB HG100W Adapter R ❿
____⓫ ____ MBP98325_______NI-ND6-E Motorized DIC Sextuple Nosepiece ❾
____⓬ ____ MBN91920_______NI-FA FL/DIC Analyzer
____⓭ ____ MBN74960_______D-LP Lambda Plate
⓮ _____ -_______________________D-C DIC Sliders

⓬ ⓭ ⓮

Ni-U simultaneous multichannnel imaging set 15-2

____‐_________________________________Objectives
_____________ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
_____________ MBD93000_______NI-SS Substage
_____________ MBD94000_______NI-CH Condenser Holder
____⓯ ____ MBL99000________NI-CUD Universal Condenser Dry
____⓰ ____ MBH99000_______NI-CALN1 2-4X Auxiliary Lens for N1Position*1*2
____⓱ ____ MBH70200_______D-C 2-4X Auxiliary Lens for N2 Position*1*3 ⓯

____⓲ ____ MBH72300_______D-C DIC N1 DRY DIC Module


____⓳ ____ MBH72310_______D-C DIC N2 DRY DIC Module
____⓴_____ MBN74940_______D-DP DIC Rotatable Polarizer ⓰ ⓱
____ ____ MBF95410_______NI-CTLB Control Box B
____ ____ MBF95120_______NI-SRCP Simple Remote Control Pad
_____________ MQA21020______DS-L3 DS Camera Control Unit
⓲ ⓳ 
_____________ MQF52055_______AC Adapter 2
_____________ MXA22113_______C-CTC Camera Trigger Cable U3/L3
_____________ MEF51001________TI-100WRC 100W Lamphouse Remote Cable
   
_____________ MBE95205_______NI-LH Precentered Lamphouse

⓴ Option___________________________
 ____MBB96920_______ NI-RPSAB DSC Adapter B (for the Roper Cascade Series)
 ____MBH70210_______ D-C PH-1 PH Module*4
 ____MBH70220_______ D-C PH-2 PH Module*4
 ____MBH70230_______ D-C PH-3 PH Module*4
 ____MBH70250_______ D-C DF Dark Field Module*5

 *1 Required when using 2x and 4x objectives


 *2 Cannot be used when N1 Dry DIC Module is in use
*3 Cannot be used when N2 Dry DIC Module is in use
*4 For use in combination with phase contrast objectives
*5 Required for darkfield observation
Ci-E brightfield set 15
16
• Ci-E set for brightfield observation.

_____________ MBA93000_______ECLIPSE Ci-E Main Body


____❶ ____ MBB93800_______C-TE2 Ergonomic Binocular Tube
____❷ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube ❶
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.)
____‐_________________________________Objectives
____❸ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder ❷
____ ________ MBL99300________CI-C-E Motorized Swing-out Condenser

Option___________________________
❹ ____MBP91705_______ CI-NS Spacer for Nosepiece
❺ ____MBN97000_______ CI-FCH Filter Cassette Holder
_________MXA22122_______ CI-IRC IR Cut Filter for Ci ❸ ❹ ❺
❻ ____MBB75360_______ C-IA Analyzer Tube for First-order Red Compensation
❼ ____MBB75380_______ C-TP Polarizer for First-order Red Compensation
For First-order Red Compensation
❽ ____MBB75350_______ C-ISA Analyzer Tube for Simple Polarization
❾ ____MBB75370_______ C-SP Polarizer for Simple Polarization

❻ ❼

For Simple Polarization

❽ ❾
Ci-L/Ci-S brightfield set 15
17
• Ci-L/Ci-S set for brightfield observation.

Ci-L/Ci-S

_____________ MBA94010_______ECLIPSE Ci-S Main Body


_____________ MBA95000_______ECLIPSE Ci-L Main Body
____❶ ____ MBB93800_______C-TE2 Ergonomic Binocular Tube
____❷ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.)
____❸_____ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD
____‐_________________________________Objectives
____❹ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder ❻ ❼ ❽
____❺ ____ MBL71100________C-C Abbe Condenser NA 0.9 For First-order Red Compensation For Simple Polarization

❾ ❿ ⓫ ⓬ ⓭ ⓮

Option___________________________

❻ ____MBB92100_______ C-TB Binocular Tube
_________MBP71325_______ C-N6A Sextuple Nosepiece with Analyzer Slot

❼ ____MBP91705_______ CI-NS Spacer for Nosepiece
❽ ____MBN97000_______ CI-FCH Filter Cassette Holder
_________MXA22122_______ CI-IRC IR Cut Filter for Ci
_________MBP71325_______ C-N6A Sextuple Nosepiece with Analyzer Slot
❾ ____MBB75380_______ C-TP Polarizer for First-order Red Compensation

❺ ❿ ____MBN91921_______ C-AS Analyzer Slider for First-oder Red Compensation*1*2



⓫ ____MBB75360_______ C-IA Analyzer Tube for First-order Red Compensation
⓬ ____MBB75370_______ C-SP Polarizer for Simple Polarization
⓭ ____MBN74925_______ D-SA Analyzer Slider for Simple Polarization*1*3
⓮ ____MBB75350_______ C-ISA Analyzer Tube for Simple Polarization
*1 For use in combination with C-N6A Sextuple Nosepiece with Analyzer Slot.
*2 C-IA Analyzer Tube for First-order Red Compensation can be used as an alternative.
*3 C-ISA Analyzer Tube for Simple Polarization can be used as an alternative.
Ci-E epi-fluorescence set 15
18
• Ci-E set for epi-fluorescence observation.

_____________ MBA93000_______ECLIPSE Ci-E Main Body ❶

____❶ ____ MBB93800_______C-TE2 Ergonomic Binocular Tube


____❷ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube
_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.) ❷
____❸ ____ MBE94310_______CI-FL Epi-fluorescence Attachment
____❹ ____ -_______________________Filter Cubes
____❺ ____ MBF72655_______C-HGFI HG Precentered Fiber Illumination Intensilight
____❻ ____ MBF71610_______C-HGFIF15 HG Fiber
____❼ ____ MBF72311_______C-HGFIB HG100W Adapter R
____‐_________________________________Objectives
____❽ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder ❼ ❻
_____________ MBL99300________CI-C-E Motorized Swing-out Condenser ❸ ❽

❹ ❺

Option___
❾ ____MBB93100_______ C-TF Trinocular Tube F
❿ ____MBB93110_______ C-TT Trinocular Tube T

_________MBB73520_______ Y-TV TV Tube
_________MQD42000______ C-mount TV Adapter A
⓫ ____MBE25301_______ Lamphouse HMX-3B
⓫ ⓬ ____MBF33342_______ Mercury Lamp Socket S 100W BL
⓭ ____MBE75010_______ C-FC Epi FL Collector Lens
❾ ❿ ⓭ ⓮ ⓯ ⓰ ⓮ ____MBF12321_______ C-SHG1 Power Supply for HG 100W
⓯ ____MBE75060_______ C-FC Epi-FL Centering Tool
⓰ ____MBE74100_______ D-FL Epi-fluorescence Attachment*
* Up to 6 filter cubes can be attached.
Ci-L/Ci-S epi-fluorescence set 15
19
• Ci-L/Ci-S set for epi-fluorescence observation.

_____________ MBA95000_______ECLIPSE Ci-L Main Body ❶


_____________ MBA94010_______ECLIPSE Ci-S Main Body
____❶ ____ MBB93800_______C-TE2 Ergonomic Binocular Tube
____❷ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube

_____________ MAK10100_______CFI 10X Eyepiece (2 pcs.)
____❸ ___ MBE94310_______CI-FL Epi-fluorescence Attachment
____❹ ____ -_______________________Filter Cubes
____❺_____ MBF72655_______C-HGFI HG Precentered Fiber Illumination Intensilight
____❻ ____ MBF71610_______C-HGFIF15 HG Fiber
____❼_____ MBF72311_______C-HGFIB HG100W Adapter R ❸

_____________ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD


‐_____________________________________Objectives

____❽ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder
_____________ MBL71100________C-C Abbe Condenser NA 0.9


Option___
❾ ____MBB93100_______ C-TF Trinocular Tube F
❿ ____MBB93110_______ C-TT Trinocular Tube T
❽ ❺ _________MBB73520_______ Y-TV TV Tube
_________MQD42000______ C-mount TV Adapter A
⓫ ____MBE25301_______ Lamphouse HMX-3B
⓬ ⓬ ____MBF33342_______ Mercury Lamp Socket S 100W BL
⓭ ____MBE75010_______ C-FC Epi FL Collector Lens
⓮ ____MBF12321_______ C-SHG1 Power Supply for HG 100W
⓯ ____MBE75060_______ C-FC Epi-FL Centering Tool

⓰ ____MBE74100_______ D-FL Epi-fluorescence Attachment*
* Up to 6 filter cubes can be attached.
❾ ❿ ⓭ ⓮ ⓯ ⓰
Ci phase contrast set 15
20
• Ci set for phase contrast observation.

_____________ MBA93000_______ECLIPSE Ci-E Main Body ❶


_____________ MBA95000_______ECLIPSE Ci-L Main Body
_____________ MBA94010_______ECLIPSE Ci-S Main Body
___❶ ____ MBB93800_______C-TE2 Ergonomic Binocular Tube ❷
____❷ ____ MBB96800_______C-TEP2 DSC Port for Ergonomic Binocular Tube

____❸ ____ MAK10100_______CFI 10X Eyepiece (2 pcs.)
____❹ ____ MAK85000_______C-CT Centering Telescope with UW Adapter
____❺_____ MBP71315_______C-N6 ESD Sextuple Nosepiece ESD*1
____‐_________________________________Objectives
____❻ ____ MBC91110_______C-SR2S Right Handle Stage with 2SHolder

____❼ ____ MBL73100________C-C Phase Contrast Turret Condenser ❼ ❽
____❽_____ MBN97000_______CI-FCH Filter Cassette Holder

❾ ❿ ⓫

Option___________________________
❾_____MBB93100_______ C-TF Trinocular Tube F
❿ ____MBB93110_______ C-TT Trinocular Tube T
⓫ ____MBB73520_______ Y-TV TV Tube
_________________________________ C-mount TV Adapter A

*1 Not required for Ci-E microscope.


Tube/Port/TV-Tube/TV-Adapter 21

Tubes______________________________ Beam Split Ratio (Eyepiece/Upper port/Rear port) Field Number


____❶_____ MBB94510_______NI-TT-E Morized Quadrocular Tilting Tube 100/0/0, 0/100/0, 0/0/100 22/25
____❷ ____ MBB94521 ______NI-TT Quadrocular Tilting Tube 100/0/0, 0/100/0, 0/0/100 22/25
____❸_____ MBB92100 ______C-TB Binocular Tube 100/-/- 22 ❶ ❷ ❸
____❹_____ MBB93100 ______C-TF Trinocular Tube F 100/0/-, 0/100/- 22/25
____❺_____ MBB93110 ______C-TT Trinocular Tube T 100/0/-, 20/80/-, 0/100/- 22/25
_____________ MHB43200 ______C-TT-C Trinocular Tube T 100/0/-, 0/100/- (for C2 Scanning Head) 22/25
____❻_____ MBB93800 ______C-TE2 Ergonomic Binocular Tube 100/-/0, 50/-/50 22 ❹ ❺ ❻


Ports_______________________________ Magnification
____❼_____ MBB96710 ______NI-RPZ-E Motorized DSC Zooming Port for Quadrocular Tube*1 0.6x - 2.0x
*2
____❽_____ MBB96721 ______NI-RPZ DSC Zooming Port for Quadrocular Tube 0.6x - 2.0x
❼ ❽
____❾_____ MBB96800 ______C-TEP2 DSC Port for Ergonomic Binocular Tube 0.7x

TV-Adapter, etc.
TV-Tube ____⓬ ____ MAB53410_______V-T Photo Adapter
____❿ ____ MBB94700_______C-TAQ Tube Adapter for Quadrocular Tube ____⓭ ____ MQD42060______C-Mount TV Adapter 0.6X
____⓫ ____ MBB73520_______Y-TV TV Tube ____⓮ ____ MQD42040______C-Mount TV Adapter 0.45X
⓬ ⓭ ⓮ ⓯ ____⓯ ____ MQD51040______C-Mount TV Adapter 0.35X
____ ________ MBB73550_______Y-TV 0.55 TV Tube
____⓰ ____ MQD42140______C-Mount TV Adapter VM4X
*1 For use in combination with NI-TT-E Motorized Quadrocular Tilting Tube ____⓱ ____ MQD42120______C-Mount TV Adapter VM2.5X
*2 For use in combination with both NI-TT-E Morized Quadrocular Tilting Tube and
NI-TT Quadrocular Tilting Tube. ____⓲ ____ MQD42000______C-Mount TV Adapter A
⓰ ⓱ ⓲
_____________ MQD42070______C-Mount Adapter 0.7X
_____________ MQD42055______C-Mount Adapter 0.55X
_____________ MHV55070_______A1-U-TT FN1/Ni Adapter (for A1 Scanning Head)*3
❿ ⓫ _____________ MHV40100_______C2-NI-TT Quadrocular Tilting Tube (for C2 Scanning Head)*3

*3 To be used in combination with NI-TT-E Motorized Quadrocular Tilting Tube or


NI-TT Quadrocular Tilting Tube
Eyepiece/Substage/Stage 22

Eyepiece, etc.__________________ Field Number Reticule


____❶_____ MAK10100 CFI 10X Eyepiece 22 -
____❷_____ MAK30100 CFI UW 10X Eyepiece 25 -
_____________ MAK11100 CFI 10XM Eyepiece with Photo Mask 22 Photomask ❾ ❿ ⓫ ⓬ ⓭
_____________ MAK31100 CFI UW 10X M Eyepiece with Photo Mask 25 Photomask
____❸_____ MAK10150 CFI 15X Eyepiece 14.5 -
____❹_____ MAK99000 CFI UW EG Eye Guard - -

⓮ ⓯ ⓰
⓱ ⓲

Stage
____❾ ____ MBC91010_______NIE-CSRR2 Right Handle Rotatable Ceramic Stage with Holder
⓳ ____❿ ____ MBC91030_______NIU-CSRR2 Right Handle Rotatable Ceramic Stage with Holder
❶ ❷ ❸ ❹ ____⓫ ____ MBC91110_______C-SR2S Right Handle Stage with 2S Holder
____⓬ ____ MBC91115_______C-CSR1S Right Handle Ceramic Stage with 1S Holder
____⓭ ____ MBC91130_______C-CSR Right Handle Ceramic Stage
____⓮ ____ MBC95020_______C-H2L Specimen Holder 2L
Substage
⓴ ____⓯ ____ MBC95025_______C-H1L Specimen Holder 1L
____❺ ____ MBD93010_______NI-SSR Substage for Rotatable /Motorized Stage
____⓰ ____ MBC90040_______C-H1C Double Arm Specimen Holder
____❻_____ MBD93000_______NI-SS Substage
____⓱ ____ MBC96100_______NI-S-E Motorized XY Stage
____❼ ____ MBD94000_______NI-CH Condenser Holder  ____⓲ ____ MBC96110_______NI-SA Motorized XY Stage Adapter
____❽_____ MBD93030_______NI-SSF Substage for Focusing Nosepiece
____⓳ ____ MBF95130_______NI-SJ Joystick for Motorized Stage
____⓴ ____ MBF95110_______NI-ERG NI Ergo Controller

 ____ ____ MXB22406_______NI-SH-D Dish Holder


____ ____ MBC74001_______FN-3PS2 FN1 Standard Stage

____ ____ MBC94100_______NI-3PSA Adapter for FN1 Standard Stage
❺ ❻ ❼ ❽
Condenser/Intermediate module/Other accessory 23

Condenser______________________ NA O.D. (mm) Objective Magnification*


____❶_____ MBL71100 _______C-C Abbe Condenser 0.9 1.9 4x-100x
____❷_____ MBL71200 _______C-C Achromat Condenser 0.8 2.0 4x-100x
____❸_____ MBL11300 _______Achromat Swing-out Condenser 2-100x 0.9/0.22 1.8 2x-100x
____❹_____ MBL71500 _______C-C Slide Achro Condenser 2-100x 0.9 2.2 2x-100x
____❺_____ MBL71300 _______C-C Achromat Swing-out Condenser 1-100x 0.8/0.12 3.2 1x-100x
____❻_____ MBL71400 _______C-C Achromat Aplanatic Condenser 1.4 1.6 10x-100x ❶ ❷ ❸ ❹ ❺
_____________ MBL16100________X LWD Condenser 0.65 10.2 4x-40x
____❼_____ MBL12010 _______Darkfield Condenser Dry 0.8-0.95 4 20x-40x
____❽_____ MBL12000 _______Darkfield Condenser Oil 1.2-1.43 1.5 20x-100x
____❾_____ MBL78700 _______D-CUO DIC Condenser Oil 1.4 1.6 10x-100X ❻ ❼ ❽ ❾
_____________ MBL99000 _______NI-CUD Universal Condenser Dry 0.88 2.5 2x-100X
_____________ MBL99800 _______NI-CUD-E Motorized Universal Condenser Dry 0.88 2.5 2x-100X
*F.O.V.22

Intermediate Module
____❿_____ MBB75710_______C-ER Eyelevel Riser
____⓫_____ MBB74100_______Y-IDP Double Port (Beam split ratio: Eyepiece/Rear Port = 55/45, 100/0)
____⓬ ____ MBB75500_______Y-IM Magnification Module (1x, 1.25x, 1.5x, 2x)
____⓭ ____ MBB75400_______Y-IDT Drawing Tube
❿ ⓫ ⓬ ⓭

Other accessories
____⓮_____ MBE49100_______D-FLE Filter Cube for Reflected Illumination
____⓯_____ MBE49200_______D-FLD Filter Cube for Darkfield Illumination
____⓰ ____ MBH79000_______D-ES Slider for Reflected Illumination
____⓱ ____ MXA22129_______C-FK Fine Focus Knob ⓮
⓯ ⓰ ⓱
_____________ MBN91802_______NI-ND2 Filter 36mm ND2*1

*1 For Ni only
Teaching accessory 24

____❶ ____ MBB75100_______Y-THF Teaching Unit Face to Face


____❷ ____ MBB75110_______Y-THS Teaching Unit Side by Side Unit B
____❸ ____ MBB75120_______Y-THM Main Teaching Unit
____❹ ____ MBB75131_______Y-THR-L Teaching Unit Side by Side Type L
❶ ❷ ❸
____❺ ____ MBB75150_______Y-THSP Support for Side by Side ❹ ❺
____❻ ____ MBB75141_______Y-THPL LED Pointer Unit for Teaching Head
____❼ ____ MBF81001_______TH-AC2 AC Adapter for TH Pointer Unit
❻ ❼

Face-to-face Side-by-side

Five-person type Ten-person type


TO ENSURE CORRECT USAGE, READ THE CORRESPONDING
WARNING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.

Company names and product names appearing in this brochure are their registered trademarks or trademarks.
N.B. Export of the products* in this brochure is controlled under the Japanese Foreign Exchange and Foreign Trade Law.
Appropriate export procedure shall be required in case of export from Japan.
*Products: Hardware and its technical information (including software)
Monitor images are simulated.

Specifications and equipment are subject to change without any notice or obligation on the part
of the manufacturer. April 2013 ©2013 NIKON CORPORATION

NIKON CORPORATION
Shin-Yurakucho Bldg., 12-1, Yurakucho 1-chome, Chiyoda-ku, Tokyo 100-8331, Japan
phone: +81-3-3216-2375 fax: +81-3-3216-2385
http://www.nikon.com/instruments/

NIKON INSTRUMENTS INC. NIKON SINGAPORE PTE LTD NIKON INSTRUMENTS S.p.A.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A. SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668 ITALY phone: +39-055-300-96-01 fax: +39-055-30-09-93
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A. only)
fax: +1-631-547-0306
NIKON MALAYSIA SDN. BHD. NIKON AG
MALAYSIA phone: +60-3-7809-3688 fax: +60-3-7809-3633 SWITZERLAND phone: +41-43-277-28-67 fax: +41-43-277-28-61
http://www.nikoninstruments.com/
NIKON INSTRUMENTS EUROPE B.V. NIKON INSTRUMENTS KOREA CO., LTD. NIKON UK LTD.
KOREA phone: +82-2-2186-8400 fax: +82-2-555-4415 UNITED KINGDOM phone: +44-208-247-1717 fax: +44-208-541-4584
Tripolis 100, Burgerweeshuispad 101, 1076 ER Amsterdam,
phone: +31-20-7099-000 fax: +31-20-7099-298 NIKON CANADA INC. NIKON GMBH AUSTRIA
http://www.nikoninstruments.eu/ CANADA phone: +1-905-602-9676 fax: +1-905-602-9953 AUSTRIA phone: +43-1-972-6111-00 fax: +43-1-972-6111-40
NIKON INSTRUMENTS (SHANGHAI) CO., LTD. NIKON FRANCE S.A.S. NIKON BELUX
CHINA phone: +86-21-6841-2050 fax: +86-21-6841-2060 FRANCE phone: +33-1-4516-45-16 fax: +33-1-4516-45-55 BELGIUM phone: +32-2-705-56-65 fax: +32-2-726-66-45
(Beijing branch) phone: +86-10-5831-2028 fax: +86-10-5831-2026 NIKON GMBH
(Guangzhou branch) phone: +86-20-3882-0552 fax: +86-20-3882-0580 GERMANY phone: +49-211-941-42-20 fax: +49-211-941-43-22

Ver. 1 PDF only (April 2013)T


En

Potrebbero piacerti anche