Sei sulla pagina 1di 4

Beam Deflection Check to EN1992 Edge Cantilver on X1-X8 Clause 7.4.

2
(250x1000)

Deflection check to EC2 [7.4.2] - Πρόβολος στον άξονα Χ8 (όμοια στον Χ1)

Geometric Properties
Beam depth h  1000mm Beam width b  250mm

Beam span lbeam  3.75m

Bar diameter dϕ  25  mm Comp bar diam d'ϕ  20  mm

Bar numbers nbar.ten  4 Number of comp bars ncomp  3


in two layers

link diam dl  12mm

Cover to reinforcement c cov  25mm

Static depth d  h  c cov  1.5dϕ  dl  925.5  mm

Concrete Properties

Characteristic compressive strength fck  30MPa

3
Concrete unit weight (c) : γc  25  kN  m

3
Young's Modulus for Steel (Es) : Es  200  10  MPa

fcm  fck  8MPa  38  MPa


Concrete compressive stress (fcm)

0.3
 f  MPa 1 
cm
Young's Modulus for Concrete (Ec) : Ecm  22     GPa  32.837  GPa
 10 

Es
Modulus Ratio (n) : nmod   6.091
Ecm

by GC
Beam Deflection Check to EN1992 Edge Cantilver on X1-X8 Clause 7.4.2
(250x1000)

Reinforcement Properties and Ratios

Yield Stress fyk  500MPa Rebar B500C

2
Required Rebar (for SLS) Asreq  1553mm

 π  d 2 
ϕ 3 2
Provided Tension Rebar Asprov.ten  nbar.ten     1.963  10  mm
 4 

Provided Compression Rebar  π  d' 2 


ϕ 2
Asprov.comp  ncomp     942.478  mm
 4 

Required tension reinforcement ratio at mid-span to resist


the moment due to the design loads (at support for
cantilevers)

Asreq
ρ   0.671  %
bd

Required compression reinforcement ratio at mid-span to


resist the moment due to design loads (at support for
cantilevers)

Asprov.comp
ρ'   0.407  %
bd

fck
3
Reference reinforcement ratio ρo  10   0.548  %
MPa

Basic Beam to Depth Ratios and Obtained value

system  5 K  1 if system = 1  0.4


1.3 if system = 2
1.5 if system = 3
1.2 if system = 4
0.4 otherwise

by GC
Beam Deflection Check to EN1992 Edge Cantilver on X1-X8 Clause 7.4.2
(250x1000)

ldbasic  14 if system = 1  ρ  1.5% 8


20 if system = 1  ρ  1.5%
500  Asprov.ten
18 if system = 2  ρ  1.5%
ratio310_fs   1.264
26 if system = 2  ρ  1.5% fyk
 Asreq
20 if system = 3  ρ  1.5% MPa

30 if system = 3  ρ  1.5%
17 if system = 4  ρ  1.5%
24 if system = 4  ρ  1.5%
6 if system = 5  ρ  1.5%
8 otherwise

  3 
  
  
2
 fck ρo fck  ρo
LDratio  K  11  1.5    3.2    1  if ρ  ρo  11.379
 MPa ρ MPa  ρ  
 fck ρo 1 fck ρ' 
K  11  1.5      otherwise
 MPa ρ  ρ' 12 MPa ρo 
 

Check
 lbeam 


check_deflection  if  LD ratio  ratio310_fs   d
"Ok" "Fails"  "Ok"

by GC
Beam Deflection Check to EN1992 Edge Cantilver on X1-X8 Clause 7.4.2
(250x1000)

lbeam
LDratio  ratio310_fs  14.387  4.052 ldbasic  8
d

by GC

Potrebbero piacerti anche