Sei sulla pagina 1di 4

CE PROJECTS 1

CE 506

DESIGN INPUTS

Design Code and Reference:

WANG AND SALMON REINFORCED CONCRETE DESIGN, 5TH EDITION

ACI 31B-05 AMERICAN CONCRETE INSTITUTE “BUILDING CODE


REQUIREMENTS FOR REINFORCED CONCRETE”

ASEP ASSOCIATION OF STRUCTURAL ENGINEERS OF THE PHILIPPINES


HANDBOOK OF STRUCTURAL STEEL SHAPES AND SECTIONS

NELSON DESIGN OF CONCRETE STRUCTURES, 12TH EDITION

NSCP, 2001 EDITION NATIONAL STRUCTURAL CODE OF THE PHILIPPINES, VOLUME 1,


PHILIPPINES 5TH EDITION

DESIGN DEAD LOADS

UNIT WEIGHT OF CONCRETE 24.00 KN/m3


FLOOR FINISH
CEMENT FINISH 25mm ON STONE-CONCRETE FILL 1.530 kPa
CEILING
MECHANICAL DUCT ALLOWANCE 0.200 kPa
PLASTER ON TILE/CONCRETE 0.240 kPa
WALL
4” CHB 2.150 kPa
6” CHB 3.110 kPa
PARTITION AND INTERIOR WALLS (LATERAL LOAD) 0.250 kPa
FRAME PARTITION 1.000 kPa
ELECTRICAL/MECHANICAL/PLUMBING 0.350 kPa
WATERPROOFING (LIQUID APPLIED) 0.050 kPa
THREE-PLY READY ROOFING 0.050 kPa
UTILITIES 0.200 kPa

DESIGN LIVE LOADS

LIBRARIES
READING ROOMS 2.900 kPa

Submitted by: Date


DESIGN PROJECT MEGAPEPA
Title Student No: Date
“REHABILITATION OF MUSEO-BIBLIOTECA DE FILIPINAS” 1310:605,408,727,562,
1311005
Submitted to: Page
apd P-6.1
CE PROJECTS 1
CE 506

STACK ROOMS 7.200 kPa


OFFICES USE 2.400 kPa
COMPUTER USE 4.800 kPa
THEATERS
FIXED SEATS 2.900 kPa
STAGE AREAS 7.200 kPa
LOBBIES 4.800 kPa
CORRIDOR 3.800 kPa
STAGES ACCESSORIES
FOLLOW SPOT, PROJECTION AND CONTROL ROOMS 2.400 kPa
RESTAURANT 4.800 kPa
RESTROOM 2.400 kPa
EXIT FACILITIES 4.800 kPa
SEMINAR ROOM 4.800 kPa
CEILING FRAMING
OVER STAGES 1.000 kPa
ELEVATOR AND DUMBWAITERS (Dead and Live loads) 2(total load)

WIND LOADS

ZONE 2 (NCR)
V= 200 kph
I = 1.0

SEISMIC LOADS

ZONE 4
SEISMIC ZONE FACTOR, Z= 0.40
SEISMIC TYPE B, (6.5 ≤ M < 7)
R/SMRF= 8.5
I = 1.0
NEAREAST FAULT LINE (Marikina)

Submitted by: Date


DESIGN PROJECT MEGAPEPA
Title Student No: Date
“REHABILITATION OF MUSEO-BIBLIOTECA DE FILIPINAS” 1310:605,408,727,562,
1311005
Submitted to: Page
apd P-6.2
CE PROJECTS 1
CE 506

REINFORCING STEEL
REINFORCING STEEL SHALL CONFORM TO LATEST EDITION OF ASTM A615:

GRADE 60, DEFORMED WITH MINIMUM YIELD STRENGTH fy = 414 MPa (60,000 PSI) FOR
BARS 16mm TO 36mm.

GRADE 40, DEFORMES WITH MINIMUM YIELD STRENGTH fy = 276 MPa (40,000 PSI) FOR
BARS 10mm TO 12mm.

MATERIAL SPECIFICATION

CONCRETE STRENGTH:
BEAMS f’c = 28 MPa (4060 PSI)
COLUMN f’c = 28 MPa (4060 PSI)

STAIR f’c = 27.60 MPa (4 000 psi)


LEAN CONCRETE f’c = 27.60 MPa (4 000 psi)
NON- STRUCTURAL R.C WALL, SLAB ON FILL
LINTEL BEAM AND STIFFENER COLUMN f’c = 20.70 MPa (3 000 psi)
Submitted by: Date
DESIGN PROJECT MEGAPEPA
Title Student No: Date
“REHABILITATION OF MUSEO-BIBLIOTECA DE FILIPINAS” 1310:605,408,727,562,
1311005
Submitted to: Page
apd P-6.3
CE PROJECTS 1
CE 506

ASTM A706, GRADE 60, REINFORCING STEEL SHALL BE USED FOR:


MAIN REINFORCEMENT, SPIRALS, TIES AND STIRRUPS IN THE FRAME MEMBERS
(BEAMS AND COLUMNS) COMPRISING THE LATERAL FORCE RESISTING SYSTEM.
WELDED OR FIELD- BENT BARS
SHEAR WALL BOUNDARY MEMBERS REINFORCEMENT, UNLESS THE CRITERIA OF
THE UBC, SECTION 192.2.5.1 ARE SATISFIED.

WELDED WIRE FABRIC PER ASTM A185. FURNISH IN FLAT SHEETS, NOT ROLLS LAP EDGES
1 ½ MESH MINIMUM.

Submitted by: Date


DESIGN PROJECT MEGAPEPA
Title Student No: Date
“REHABILITATION OF MUSEO-BIBLIOTECA DE FILIPINAS” 1310:605,408,727,562,
1311005
Submitted to: Page
apd P-6.4

Potrebbero piacerti anche