TIMESWITCH TERMINAL COMPARISONS User’s Instructions


Lifestyle Lifestyle INTRODUCTION Cont... THE LP711 7-DAY ELECTRONIC TIMESWITCH THE LP112 24hr ELECTRONIC PROGRAMMER

Common
PROGRAMMERS

Neutral

Spare
Earth
SWITCHING LP711 – a 7-day program, allowing for different

Live
LP112 – a 24hr program, with linked central heating and hot

On

Off
MAKE MODEL
Current Models timings on each day of the week, up to 3 heating periods water on for up to 3 heating periods each day, and every day
ON 1 – start of first timed period
each day. the same.
Drayton Tempus 1, 2 (new models) N L 1 3 2 4
SINGLE DUAL SINGLE DUAL OFF 1 – end of first timed period If the engineer has set your program and timings – you If the timings haven’t been set for you, then your programmer
Lifestyle LP111, LP711 N L 1 3 2 4 Want to leave a timing as it is? Just press SET? and move on wont need to do anything else. Just keep this guide in a safe will still be on the factory-set standard 24hr program, with
CHANNEL CHANNEL Switchmaster 300 N L 4 1 CHANNEL CHANNEL ON 2 – start of second timed period to the next one. place for future reference. central heating and hot water operating together on the
Timeswitch Programmer Discontinued/Competitors’ Models Timeswitch Programmer OFF 2 – end of second timed period If you need to reset your timings to the standard program and same settings for every day of the week. But it’s easy to
ACL TC (Towerchron) 2 1 4 7 start again, press ‘SET’ and ‘+’ together to go back to the INTRODUCTION make changes – just follow the instructions.
for heating OR hot water for heating AND hot water Drayton Tempus 1, 2 (old models) N L 1 2 3 4 for heating OR hot water for heating AND hot water ON 3 – start of third timed period pre-set program. Want to leave a timing as it is? Press SET? and move on to
Switchmaster 980 N L 4 1 Lifestyle programmers will automatically switch your central the next one.
OFF 3 – final switch-off of the day
Danfoss Randall TS15, 75 (Mk18) E N L 1 4 2 5/6 heating and hot water on and off at times that suit you.
If you need to reset your timings to the standard program
Danfoss Randall TS715 E N L 1 4 2 3 The standard program Depending on your system, central heating and hot water can and start again, press ‘SET’ and ‘+’ together to go back to
If the engineer has set your program and timings – you won’t
Danfoss Randall TS975 E N L 5 4 6 1,2,3 either both come on and off at the same time, or work
need to do anything else. Just keep this guide in a safe place Your system will come on for up to 3 heating periods every the pre-set program.
Danfoss Randall SET1, SET1E E N L 5 4 6 independently. The red light on the front of the programmer
Danfoss Randall SET4 E N L 5 4 6 for future reference. 24hrs. ON1 starts the first one, OFF1 finishes it, and so on. If you don’t press anything for two minutes, the programmer
shows whem each one is on automatically goes back to normal operation.
Danfoss Randall 103, 103E, 103E5, 103E7 4 5 6 3 1 2 Notice that ON2 and OFF2 are set to the same time.* This
Danfoss Randall 911, 971 E N L 5 6 4 2 DAY-TO-DAY VARIATIONS means your system won’t respond, but if you want to activate There are 4 models in the Lifestyle range:
Grasslin Towerchron QE1 N L 2 4 3 that middle period or change any other timings – read on. The standard program
Grasslin Towerchron T2001, T2001Q E N L 7
Sometimes you might need to change the way you use your I LP112 – a 24hr program, with linked central heating and hot Your system will come on for up to 3 heating periods every
Honeywell ST 6100A, ST 6100C N L 1 4 2
system temporarily – perhaps due to an exceptionally cold day. water on for up to 3 heating periods each day, and every day 24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
Honeywell ST 7000B L 3 2
the same. Notice that on the standard program ON2 and OFF2 are set
Horstmann Centaur SC1, SC7 N L 4 3
Here’s how to do it – without affecting the timings in your
I LP241 – a 24hr program, with central heating and
LP111, LP711 LP112, LP241, LP522, LP722 LP111, LP711 LP112, LP241, LP522, LP722 STANDARD PROGRAM to the same time.* This means your system won’t respond,
Horstmann Centaur Plus, C11, C17 N L 2 4 3
program. SWITCHING but if you want to activate that middle period, or change any
Horstmann Emerald 423, Pearl Auto E N L 3 4
MON-FRI SAT-SUN hot water working independently for up to 3 heating periods other timings – read on.
Horstmann 517, Coronet, H11, H17 E N L 5 4 6
Landis & Staefa RWB3 N L 4 3 Switching on and off each day, and every day the same.

SINGLE DUAL Landis & Staefa


Landis & Staefa
RWB30, RWB50, 100, 152, 170
RWB7 N
N
L
L
2
2
4
4
3
3
1
SINGLE DUAL On the front of the timeswitch there is an Advance/Boost button.
It allows you to switch your system either on or off, irrespective of
ON 1 – start of first timed period

OFF 1 – end of first timed period


6.30am

8.30am
7.00am

9.00am
I LP522 – a 5/2-day program allowing for different SWITCHING STANDARD PROGRAM

CHANNEL CHANNEL Potterton Myson


Sangamo
EP4000, 4001, 4002, 5002
M6 E
N
4
L
6
5
3
4
1
2
2
CHANNEL CHANNEL the program. So if the heating is off, and you want warmth now,
you can either –
ON 2 – start of second timed period* 12.00pm 12.00pm
timings at the weekends, with central heating and hot water
working independently for up to 3 heating periods each day. ON 1 – start of first timed period 6.30am

I LP722 – a 7-day program allowing for different


Smiths Centroller Mk1, Mk2 N L 3 2
OFF 2 – end of second timed period* 12.00pm 12.00pm OFF 1 – end of first timed period 8.30am
Smiths Centroller 30 1 2 4/5 1. Press Advance to switch it on (ADV will be displayed), and it will
Smiths Centroller 300, 980 N L 4 1 stay on until the end of the next period. Or if the heating is on timings on each day of the week, with central heating and
ON 3 – start of third timed period 4.30pm 4.00pm ON 2 – start of second timed period* 12.00pm
Installation Instructions Sunvic Select 107 N L 1 3 2 4 User Instructions and you don’t need it, press Advance and it will go off until the hot water working independently for up to 3 heating periods

06490033001 ISSG 06490033001 ISSG


Sunvic SP20, SP35 N L 3 5 4 S beginning of the next ON period. OFF 3 – final switch-off of the day 10.30pm 11.00pm each day. OFF 2 – end of second timed period* 12.00pm
Venner Vennerette N L LINE LOAD
Advance will only operate in TIMED or ONCE modes. If the engineer hasn’t set your timings for you, your programmer ON 3 – start of third timed period 4.30pm
Invensys Controls Invensys Controls will work with a standard program that has been set at the
Sales: 0845 1305522 / Technical Helpline: 0845 1307722 Sales: 0845 1305522 / Technical Helpline: 0845 1307722 2. Press & Hold Boost to switch on for an extra hour ( & BST will OFF 3 – final switch-off of the day 10.30pm
Changing the timings factory. If this doesn’t suit you, it’s very easy to change it –
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk be displayed), then Press again for two ( ) or three ( ) hours.
I Press the SET? button and you’ll see ‘SET PROG?’.
when you’ve read this introductory section, simply go to the
To cancel Boost, Press Boost again ( ). Or if the heating is
section that contains your programmer model.
already on, using Boost will extend the ON time by one, two or Changing the timings
PROGRAMMER TERMINAL COMPARISONS three hours.
INSTALLATION INSTRUCTIONS What is a programmer?
I Press the SET? button and you’ll see ‘SET PROG?’.

H/W on
H/W off
Neutral

C/H on
C/H off
Over-riding the program
Earth

Live

PLEASE NOTE: INSTALLATION MUST ONLY BE MAKE MODEL


...an explanation for householders
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR Current Models Remember:
Set all weekdays
HEATING ENGINEER. Drayton Tempus 6, 7 (new models) N L 1 2 3 4 Programmers allow you to set ‘On’ and ‘Off’ time periods. At the side of the display there are I Make your changes using the SET?, YES/-, and + buttons on
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE. Lifestyle LP112, LP241, LP522, LP722 N L 1 2 3 4 Some models switch the central heating and domestic hot four operating modes: First you set the times that are going to be the same for each the programmer.
water on and off at the same time, while others allow the
I Press the YES button, and you’ll see ON1, the start of your first
Switchmaster 400, 600 N L 4 3 1 weekday, then you can select each day individually and make
TECHNICAL DATA (no connection to terminal 4 on 600) domestic hot water and heating to come on and go off at OFF = continuously off. any further adjustments. If you want each day to be quite I You can’t set ON1 as the last timing before midnight, but you
different times. can set OFF3 after midnight – providing it’s not more than 23 heating period. Adjust it in 1-minute steps using the – and +
Switchmaster 805 N L 4 2 3 1 TIMED = on for up to 3 periods a day. different, go straight to ‘Set each day’.
hours and 59 minutes after ON1. buttons. If the – and + buttons are held down, the time changes
Discontinued/Competitors’ Models ONCE = on for 1 period a day, from the start of ON1
I Press the YES button, and the display will ask ‘SET MON to FRI
Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. in 10-minute steps.
I You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
LP112, LP241, LP522 & LP722 PROGRAMMERS
ACL MP (Towerchron) 2 1 6 10 On some programmers you must also set whether you want to the end of OFF3.
LP111 & LP711 TIMESWITCHES the heating and hot water to run continuously, run under the PROG?’.
ACL FP (Towerchron) 2 1 8 11 6 10 ON = continuously on. OFF2, ON3, OFF3. If you get out of sequence, the display will
Drayton Tempus 3, 4, 6, 7 (old models) N L 1 2 3 4 chosen ‘On’ and ‘Off’ heating periods, or be permanently off.
flash a warning.
Voltage 230V a.c. +10% - 10% 50Hz Switchmaster 905, 9001 N L 4 2 3 1 Use the SELECT button under the flap to change the mode.
Danfoss Randall CP15, CP715, FP15, FP715 (Mk18) E N L 1 2 3 4 The time on the programmer must be correct. Some types This won’t alter the timings in your program, which you can
Programmer Rating 2 (1) A 230V a.c. each switch have to be adjusted in spring and autumn at the changes SWITCHING
Danfoss Randall 3020P, 3060 E 7 6 4 2
I Press SET?, and you’ll see OFF1, the end of your first heating
return to by selecting TIMED.
Danfoss Randall 4033 (link 1-6) E 7 6 5 3 4 2 between Greenwich Mean Time and British Summer Time. ON 1 – start of first timed period
Timeswitch Rating 2 (1) A 230V a.c.
I Press YES and you’ll see ON1, the start of your first heating peri-
Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 1 2 THE LP111 24hr ELECTRONIC TIMESWITCH period. Adjust this in the same way, press SET?, then repeat the
Ambient temp Operating: 0º to 45ºC Danfoss Randall 701 (link L-5 and 5-6) E N L 3 1 You may be able to temporarily adjust the heating pro- OFF 1 – end of first timed period procedure for ON2, OFF2, ON3 and OFF3.
Danfoss Randall 702 (link L-5 and 5-6) E N L 4 2 3 1 gramme, for example, ‘Override’, ‘Advance’ or ‘Boost’. These od. Adjust it in 1-minute steps using the – and + buttons.
Storage: -20ºC to 50ºC LP111 – a 24hr program, up to 3 heating periods each day, If the – and + buttons are held down, the time changes in
Danfoss Randall 922, 972 (link L-2 and 2-5) E N L 1 4 3 6 are explained in the manufacturer’s instructions. ON 2 – start of second timed peri-
and every day the same. 10-minute steps.
Without mains power Display: blank Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4 od
SET5 (link L-2 and 2-5) The heating will not work if the room thermostat has switched Want to leave a timing as it is? Just press SET? and move on
Time: always kept
Grasslin Towerchron DP 72, QE2 N L 1 2 3 4 the heating off. And, if you have a hot-water cylinder, the to the next one. OFF 2 – end of second timed peri-
Program times: always preserved
Honeywell ST 699/799 (link L-5 and 5-8) N L 7 4 6 3 water heating will not work if the cylinder thermostat detects od
If you need to reset your timings to the standard program
Programming resolution 1 minute Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4 that the hot water has reached the correct temperature.
and start again, press ‘SET’ and ‘+’ together to go back to I When you press SET? after setting OFF3, the programmer will
Honeywell ST 7100 (link L-3 and 3-6) N L 7 4 8 5 ON 3 – start of third timed period
the pre-set program. return to normal operation.
I Press SET?, and you’ll see OFF1, the end of your first heating
Wiring Fixed wiring only, to comply with Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4
current IEE regulations H121, Tiara (link L-2 and 2-5) OFF 3 – final switch-off of the day
Horstmann Centaur Plus, C21, C27 N L 1 2 3 4 The standard program period. Adjust this in the same way, press SET?, then repeat THE LP241 24hr ELECTRONIC PROGRAMMER
Maintenance Must be maintained by a qualified Landis & Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4 the procedure for ON2, OFF2, ON3 and OFF3.
Your system will come on for up to 3 heating periods every The engineer has set your program and timings – you
electrician or heating engineer 252 & 270, RWB9
24hrs. ON1 starts the first one, OFF1 finishes it, and so on. won’t need to do anything else. Just keep this guide in a LP241 – a 24hr program, with central heating and hot water
Myson Microtimer (link L-5 and 5-8) N L 7 4 6 3
safe place for future reference. working independently for up to 3 heating periods each day,
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4 Notice that ON2 and OFF2 are set to the same time.* This
Lifestyle Programmers and Timeswitches conform to the and every day the same.
(link L-5 and N-N) means your system won’t respond, but if you want to activate
essential requirements of these Directives: DAY-TO-DAY VARIATIONS If the timings haven’t been set for you, then your programmer

2004/108/EC – Electromagnetic compatibility


Potterton Myson*
Sunvic
Sunvic
Mini Minder
Select 207
SP50, SP100 (link L-3)
N
N
N
L
L
L
1
1
1
2
2
4
3
3
2
4
4
5
User’s Instructions that middle period or change any other timings – read on.
Set each day Sometimes you might need to change the way you use your
will still be on the factory-set standard 24hr program, with
central heating and hot water operating together on the
2006/95/EC – Low voltage
TIMESWITCHES SWITCHING

ON 1 – start of first timed period


STANDARD PROGRAM

6.30am
I If, after you’ve set OFF3 you want to fine-tune one or more
central heating or hot water temporarily – perhaps due to an
unusually cold day, or exceptional demand for hot water.
same timings for every day of the week. But it’s easy to make
changes, and have heating and water working independently
* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring. weekdays, press SET? until you find the first day you want to – just follow the instructions.
Here’s how to do it – without affecting your program.
OFF 1 – end of first timed period 8.30am adjust – then go through the procedure, altering any time you Want to leave a timing as it is? Press SET? and move on to
wish. Press SET? to move on to the next day. When you’ve Switching on and off the next one.
BEFORE INSTALLATION WIRING THE TIMESWITCH INTRODUCTION ON 2 – start of second timed period* 12.00pm
finished, press SET? until you see ‘SET SAT SUN PROG?’. If you need to reset your timings to the standard program
On the front of the programmer there are two Advance/Boost
First, make sure the mains supply is switched off! OFF 2 – end of second timed period* 12.00pm and start again, press ‘SET’ and ‘+’ together to go back to
Lifestyle Timeswitches will automatically control your system buttons – one for central heating and one for hot water. They the pre-set program.
Make the wiring connections as allow you to switch your system either on or off, irrespective of
PROGRAMMER ONLY by switching it on and off at times that suit you. The red light ON 3 – start of third timed period 4.30pm If you don’t press anything for two minutes, the programmer
above. Note that the output the program. So if the heating or hot water is off, and you want
on the front of the timeswitch shows when it’s on. automatically goes back to normal operation.
The programmer must be set to the type of system it is to con- contacts are voltage-free, so OFF 3 – final switch-off of the day 10.30pm warmth or hot water now, you can either –
I LP111 – a 24hr program, up to 3 heating periods
power needs to be put on to
I If you don’t want to alter any individual days, keep pressing
trol. The link on the back of the unit has two settings – P and G. The standard program
1. Press Advance to switch it on (ADV will be displayed), and it
Terminal 1 either by linking from Changing the timings
P = a fully pumped and controlled system – allowing each day, and every day the same. will stay on until the end of the next period. Or if the heating/hot Your system will come on for up to 3 heating periods every 24hrs.
Terminal L or from a separate SET? until you see ‘SET SAT SUN PROG?’.
heating and hot water to be set separately.
supply with a 3A fuse. I LP711 – a 7-day program, allowing for different I Press the SET? button and you’ll see ‘SET PROG?’. water is on and you don’t need it, press Advance and it will go ON1 starts the first one, OFF1 finishes it, and so on. Notice that on
Set weekend off until the beginning of the next ON period. the standard program ON2 and OFF2 are set to the same time for
G = a gravity-fed hot water system – which does not allow timings on each day of the week, up to 3 heating periods both central heating and hot water. * This means your system won’t
independent setting of heating without hot water, though each day. Advance will only operate in TIMED or ONCE modes. respond, but if you want to activate that middle period, or change
hot water can be controlled alone. any other timings – read on.
If the engineer hasn’t set your timings for you, your timeswitch 2. Press & Hold Boost to switch on for an extra hour ( & BST will
WIRING THE PROGRAMMER be displayed), then Press again for two ( ) or three ( ) hours.
will work with a standard program that has been set at the
USING AN EXISTING WALL-PLATE
USING A DRAYTON SIMP-L-FIT, ALTHOUGH NOT factory. If this doesn’t suit you, it’s very easy to change it – I Press the YES button, and you’ll see ON1, the start of your To cancel Boost, Press Boost again ( ). Or if the heating/hot STANDARD PROGRAM
Loosen the securing screws on the old programmer and NECESSARY, WILL MAKE THIS INSTALLATION EASIER. when you’ve read this introductory section, simply turn to first heating period. Adjust it in 1-minute steps using the – I Press YES and alter ON1, OFF1, ON2, OFF2, ON3 and OFF3 water is already on, using Boost will extend the ON time by one, SWITCHING
and + buttons. If the – and + buttons are held down, the two or three hours. CH HW
unplug it. Check that there’s 70mm clearance to the right of the page for your timeswitch model. times in the same way.
the wall-plate, and 25mm above it. Check the chart on the time changes in 10-minute steps.
Connection Charts Over-riding the program ON 1 – start of first timed period 6.30am 6.30am
next page to compare terminals and if necessary, change the Set each day
Arrowed numbers relate to OFF 1 – end of first timed period 8.30am 8.30am
wiring of the wall-plate to suit. Now plug the Lifestyle unit into
the junction box. I If, after you’ve set OFF3 for both SAT & SUN, you want to fine-
the wall-plate and tighten the securing screws. ON 2 – start of second timed period* 12.00pm 12.00pm
tune Saturday or Sunday, press SET? until you find the first day
Consult boiler handbook you want to adjust – then go through the procedure, altering any OFF 2 – end of second timed period* 12.00pm 12.00pm
Check the 3A fuse, and switch on the mains.
I Press SET?, and you’ll see OFF1, the end of your first heating
for details of pump Remember:
time you wish. Press SET? to move on to the next day. When ON 3 – start of third timed period 4.30pm 4.30pm
I Make your changes using the SET?, YES/-, and + buttons.
overrun wiring. On each side of the display there are four operating modes –
FITTING A NEW WALL-PLATE period. Adjust this in the same way, press SET?, then repeat the you press SET? after setting your hot water for Sundays, the pro-
one group for central heating, the other for hot water. You can OFF 3 – final switch-off of the day 10.30pm 10.30pm
I You can’t set ON1 as the last timing before midnight, but you
procedure for ON2, OFF2, ON3 and OFF3. grammer will go back to normal operation.
*Thermostat Key Wiring Colour Codes change modes with immediate effect by using the appropriate
The ideal location is 1.4m above floor level, with reasonable C Common GR Grey can set OFF3 after midnight – providing it’s not more than 23 SELECT button. This won’t alter the timings in your program,
lighting, good access, no condensation, no extremes of H Call for Heat Y Yellow Changing the timings
hours and 59 minutes after ON1. which you can return to by selecting TIMED.
BK Black
I Press the SET? button and you’ll see ‘SET PROG?’.
temperature, and a supporting surface that fully covers the S Satisfied
I You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
N Neutral BL Blue SAT
back of the unit. BR Brown
E Earth OFF = continuously off.
Position with 70mm clearance to the right, 25mm above, and RD Red OFF2, ON3, OFF3. If you get out of sequence, the display will
I When you press SET? after setting OFF3, the timeswitch will I If you don’t want to alter either day, keep pressing SET?
L Live
W White flash a warning. TIMED = on for up to 3 periods a day.
sufficient room to access the securing screws underneath. OR Orange return to normal operation. until the programmer goes back to normal operation. ONCE = on for 1 period a day, from the start of ON1
Fix, with terminals at the top, either direct to a flat wall using wall YG Yellow/Green
to the end of OFF3.
plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mount-
ing single conduit box type UA1 (BS4662) using M3.5 x 14 bolts. ON = continuously on.
DO NOT USE A SURFACE MOUNTING BOX.
06490033001 IssH:Invensys B/sheet_TO PRINT 8/9/10 14:08 Page 2

THE LP241 24hr ELECTRONIC PROGRAMMER Cont... THE LP522 5/2-DAY ELECTRONIC PROGRAMMER Cont... THE LP722 7-DAY ELECTRONIC PROGRAMMER Cont... SETTING THE CLOCK Cont... WIRING THE PROGRAMMER Cont...

I When you press SET? after setting OFF3 for the weekday central
Set the minute
Connection Charts
I Press SET?, and the minutes will start to flash. Use the – and +
Set the central heating Set weekday hot water
heating, the display will ask ‘SET HW MON to FRI PROG?’.
I Press the YES button, and the display will ask ‘SET CH PROG?’. I When you press SET? after setting OFF3 for the central heating, buttons to set the exact time.
the display will ask ‘SET HW MON to FRI PROG?’.

ROOM THERMOSTAT Gravity HW, Pumped CH with Room Stats


I Press YES, then set your hot water times in the same way. E L N C H
PROGRAMMER PUMP
I Press YES and you’ll see ON1, the start of your first central heat-
I Press SET?, and ‘SET DATE?’ appears in the display.
RTS 1&2 N L 3
Remember, in this mode you can have different times to your
I Press YES, then set your times in the same way. Remember, in #
RTS 4,5&6 L N 1 3 3 E
ing period. Adjust it in 1-minute steps using the – and + but- central heating if you wish.
tons. If the – and + buttons are held down, the time changes in this mode you can have different times to your central heating if If you don’t want to change the date press SET? to go back to ETS 1 E 4 1 2
N L 1 2 3 4
SET TO 2 N
5 L
10-minute steps. you wish. normal operation. If you do, go on to the next section. 'G'
Set each day
3 1 2 4 5
Set weekend central heating If, after you’ve set OFF3 for your hot water, you want to fine-tune #- LINK L-1 FOR 230V OUTPUT
SETTING THE DATE
I When you press SET? after OFF3 for the weekday hot water,
one or more weekdays, press SET? until you find the first day L 1 2 1 7 4
you want to adjust – then go through the procedure, altering any The weekday is automatically calculated from the date, so if N 2
the display will ask ‘SET CH SAT SUN PROG?’. Press YES to
time you wish. Press SET? to move on to the next day. When E 3
JUNCTION BOX BOILER
I Press SET?, and you’ll see OFF1, the end of your first central confirm, and alter the times in the same way. the weekday is incorrect you’ll need to reset the date.
you’ve finished, press SET? until you see ‘SET SAT SUN 3 E
I Press the SET? button until you see SET DATE?.
heating period. Adjust this in the same way, press SET?, then Switched and Fused 1 2 3 4 5 6 7 8 9 10 11 12
PROG?’. 2 N
repeat the procedure for ON2, OFF2, ON3 and OFF3. (3A) Mains input L N E 7 L
† For pump overrun boilers consult
manufacturer's instructions LWC3
Set weekend hot water
* See Thermostat Key

I When you press SET? after OFF3 for the weekend central If you don’t want to alter any individual days, keep pressing Set the year
Set the hot water SET? until you see ‘SET SAT SUN PROG?’.
I Press YES and the year will start to flash. Use the – and + but-
heating, the display will ask ‘SET HW SAT SUN PROG?’.
I When you press SET? after setting OFF3 for the central heating, Press YES, and follow the procedure. tons to adjust.
I When you press SET? after OFF3 for HW SAT SUN, the
the display will ask ‘SET HW PROG?’.
programmer will go back to normal operation.

THE LP722 7-DAY ELECTRONIC PROGRAMMER


Set weekend
Mid-Position Valve System
Set the month PROGRAMMER CYLINDER THERMOSTAT
I Press YES, then set your times in the same way. Remember, in
ROOM THERMOSTAT
I Press YES, and alter the central heating and hot water times in
LP722 – a 7-day program allowing for different timings on each
day of the week, with central heating and hot water working I Press SET? and the month will start to flash. Use the – and + E L N C H * S C H
this mode you can have different times to your central heating if the same way. buttons to adjust. RTS 1&2 N L 3 SET TO HTS 3
you wish. independently for up to 3 heating periods each day. N L 1 2 3 4
RTS 4,5&6 L N 1 3 # 2 C 1
'P'
I When you press SET? after OFF3 for HW SAT SUN, the pro-
I When you press SET? after setting OFF3 for the hot water, the
If the timings haven’t been set for you, then your programmer ETS 1 E 4 1 2
will still be on the factory-set standard program. This has central grammer will ask the question TEST? If you want to test your
programmer will return to normal operation.
heating and hot water operating together – with the option of program, see below, otherwise press SET? again. If you don’t 3 1 2 4 5 2 1 8 6 4 8 6 7
having different timings for each day of the week. But it’s easy want to test your program, press SET? again – and you’ll be #- LINK L-1 FOR 230V OUTPUT
THE LP522 5/2-DAY ELECTRONIC PROGRAMMER to make changes, and have heating and water working asked the question SET H’DAY? If you want to set a holiday Set the day JUNCTION BOX
independently – just follow the instructions. switch off, see page 23, otherwise press SET? again.If you’re not I Press SET? and the day will start to flash. Use the – and + but- 1 2 3 4 5 6 7 8 9 10 11 12 PUMP
LP522 – a 5/2-day program allowing for different timings at Want to leave a timing as it is? Press SET? and move on to the going to program in a holiday switch-off, then press SET? again tons to adjust. L N E 3 E
the weekends, with central heating and hot water working 2 N
next one. and your programmer will go back to normal operation. 7 L
independently for up to 3 heating periods each day. LWC3
If you need to reset your timings to the standard program and
If the timings haven’t been set for you, then your programmer Test your program L 1 5 8 7 2 3
start again, press ‘SET’ and ‘+’ together to go back to the N 2
I This test facility allows you to run through your program to check
will still be on the factory-set standard program. This means
pre-set program. E 3
that central heating and hot water will operate together, with
the same timings for weekdays and different ones for the If you don’t press anything for two minutes, the programmer that the timings are exactly what you want. Set the Day Light Saving Switched and Fused W GR OR BL YG BOILER
I Answer YES to TEST? and the display will show Monday and I Press SET? and the current DLS status will start to flash for day
weekend. But it’s easy to make changes, and have heating automatically goes back to normal operation. (3A) Mains input †
MID-POSITION VALVE 3 E
and water working independently – just follow the instructions. light saving (British Summer Time). Use the – and + buttons to 2 N
a time just past midnight. Press YES again and hold it down – LIFESTYLE 679H340-30L0 (22mm) 7 L
Want to leave a timing as it is? Press SET? and move on to The standard program turn on or off.
and the display will start to run through the days of the week, LIFESTYLE 779H340-30L0 (28mm)
the next one. Your system will come on for up to 3 heating periods every pausing for a few seconds when it reaches an ON or an OFF DRAYTON FLOWSHARE 2
If you need to reset your timings to the standard program 24hrs. ON1 starts the first period, OFF1 finishes it, and so on. Honeywell
Notice that ON2 and OFF2 are set to the same time.* This
time. At each pause, the appropriate lights and circuits will come † For pump overrun boilers consult V4073A
and start again, press ‘SET’ and ‘+’ together to go back to on. manufacturer's instructions
means your system won’t respond, but if you want to activate Landis & Gyr
the pre-set program.
I Release the YES button, and the display will stop running * See Thermostat Key MAV 3
that middle period, change any other timings – read on.
If you don’t press anything for two minutes, the programmer
and give you longer to identify a timing. I Press SET? to go back to normal operation.
automatically goes back to normal operation. WEEKDAYS WEEKENDS
SWITCHING
I Press YES once more, and the display will start running again –
HW CH HW CH
The standard program and will continue all through the week until you press SET?
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am
Your system will come on for up to 3 heating periods every
OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am
I Press SET? and your programmer will go back to normal USERS NOTES
24hrs. ON1 starts the first period, OFF1 finishes it, and so on. operation.
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
Notice that ON2 and OFF2 are set to the same time.* This
means your system won’t respond, but if you want to activate OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm Remember - The display shows the strict time sequence, so Spring-Return 2-Valve System
that middle period, or change any other timings – read on. ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm ON1 for HW could be followed by ON1 for CH, then OFF1 for ROOM THERMOSTAT PROGRAMMER CYLINDER THERMOSTAT
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm HW etc Using this feature you can program your system to E L N C H * S C H
WEEKDAYS WEEKENDS RTS 1&2 N L 3
SWITCHING SET A HOLIDAY SWITCH-OFF N L 1 2 3 4
SET TO HTS 3
RTS 4,5&6 L N 1 3 # 2 C 1
HW CH HW CH 'P'
ETS 1 E 4 1 2
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am Changing the timings Applicable to all models.
OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am
I Press the SET? button and you’ll see ‘SET PROG?’. Using this feature you can program your system to switch off 3 1 2 4 5 2 1 8 4 8 6
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm #- LINK L-1 FOR 230V OUTPUT
while you’re on holiday, then switch back on again in time to
JUNCTION BOX
OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm have the house warm for your return. 1 2 3 4 5 6 7 8 9 1 01 11 2 PUMP
ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm
I Press SET? three times and you’ll see ‘SET H’DAY?’
L N E 3 E
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm 2 N

I Press YES to SET H’DAY? and the display will show ‘00’.
7 L
LWC3
Set all weekdays
1
I Using + and -, set the number of days you want the system to
L 1 7 5 2 3 1 7 6 2 3
Changing the timings First you set the times that are going to be the same for each N 2
E 3
I Press the SET? button and you’ll see ‘SET PROG?’.
weekday, then you can select each day individually and make be off.
any further adjustments. If you want each day to be quite differ-
I Press SET, the display will show ‘H’DAY’ and the programmer
Switched and Fused
GR OR BR BL YG GR OR BR BL YG BOILER
ent, go straight to ‘Set each day.’ (3A) Mains input
CH VALVE DHW VALVE 3 E †
will switch off the system. It will then return to normal operation
I Press the YES button, and the display will ask ‘SET MON to FRI
2 N
after the set number of days. LIFESTYLE 679H308-30L1 7 L
PROG?’. LIFESTYLE 779H33530L10
DRAYTON ZV22
Remember - The programmer counts each pass through Honeywell
Set the weekday central heating
midnight as a day. So if on a Saturday morning you don’t want † For pump overrun boilers consult V4043H1056
I Press the YES button, and the display will ask ‘SET CH MON to the heating on again until Tuesday morning, set for 3 days. manufacturer's instructions Landis & Gyr
ZAV222
FRI PROG?’. * See Thermostat Key
SETTING THE CLOCK AND DATE
I Press YES and the display will ask ‘SET CH MON to FRI
PROG?’. Applicable to all models.
Make the wiring connections, as above, for the appropriate system.
SETTING THE CLOCK INSTALLERS/ENGINEERS NOTES
I Press YES and you’ll see ON1, the start of your first central heat-
For surface wiring, snap out the cable entry strip on the bottom edge
of the wall-plate. Lifestyle units are double-insulated and need no earth
ing period. Adjust it in 1-minute steps using the – and + but- The clock in your programmer has been set at the factory,
connection, but an earthing continuity (loop) terminal is provided for
tons. If the – and + buttons are held down, the time changes in and automatically accounts for British Summer Time. convenience.
I Press YES, and you’ll see ON1, the start of your first central
10-minute steps. However, should you need to set the clock, read on.

I Press the SET? button until you see SET CLOCK?.


heating period. Adjust it in 1-minute steps using the – and + After wiring, plug in the unit and tighten the securing screws.
Check the mains input has a 3A fuse, and switch on the mains.
buttons. If the – and + buttons are held down, the time changes
Then set the timings as shown in the User’s Guide.
in 10-minute steps.
ALWAYS SWITCH OFF THE MAINS BEFORE REMOVING

I Press SET?, and you’ll see OFF1, the end of your first central
THE LIFESTYLE TIMESWITCH/PROGRAMMER – AND
NEVER FIT IT TO A LIVE WALL-PLATE!
heating period. Adjust this in the same way, press SET?, then
repeat the procedure for ON2, OFF2, ON3 and OFF3. Set the hour
I Press YES once, and then the hour will start to flash. Use the
I Press SET?, and you’ll see OFF1, the end of your first central
– and + buttons to set the hour, checking for AM and PM.
heating period. Adjust this in the same way, press SET?, then
repeat the procedure for ON2, OFF2, ON3 and OFF3.