SPECIFICATION
• POWER MEASUREMENT
PER HHASE:Phase voltage,Line voltage
Current (per phase )
3 phase total:Hz, PF, KW, KVAR, Kwh, Kvarh
• PF with lead and lag detection
• Bi directional KWH/KVARH
• ACCURACY *
Current and voltage: 0.5% Frequency: 0.1Hz .
Other power functions: 1%
• VOLTAGE INPUT:Max: 600 VAC Max. L/L;40-70 Hz
• CURRENT INPUT:5 amps with 20% over range
• 3 phase 3 wire and 3 phase 4 wire
• DATA DISPLAY
3 lines of 4 digits data LED display
4 digits resolution with decimal for V,A,kw,kvar,Hz,PF with lead/lag and 8 digits accumulators for
kwh,kvarh
SIMS TRADERS 2
_______________________________________________________________________________________
SPECIFICATIONS
• Microprocessor-based design energy meter
• Complete digital design
• 6 digits with decimal display
•Watt and watt-hour function
• Temporary and permanently energy usage counting
• Class 1.0 accuracy per IEC61036
• Low staring current
• Universal for 1p3w/3p3w/3p4w application
•Wide range for 110/220/380v
• Pulse signal output
• Primary value scaling display
• Auto decimal point selection
• Programmable scale ratio setting
• Programmable 3P3W /3P4W
• DIN 96*48 standard mounting
• Interface to SCADA /PLC / DCS
• EEPROM to store parameters
• Communication Option
Photo isolated RS485
Modbus-RTU protocol
• Digital input Option
• Relay output Option
• Idle load /light load time accumulation Option
• Dimension 96W*48H*110D mm
• Panel Cutout: 92*45 mm
SIMS TRADERS 3
_______________________________________________________________________________________
8
Mechanical Characteristics
Flush mounting, DIN 96x96 mm, depth 55 mm
Panel cut out 92x92mm
Weight 0,5 kg
Measured Parameters
Voltage V (L1, L2, L3, L12, L23, L31, total)
Current (L1, L2, L3, total)
Power Factor P.F. (L1, L2, L3, total)
Active Power W (L1, L2, L3, total)
Apparent Power S (L1, L2, L3, total)
Frequency
Active Energy +Kwh
Reactive Energy +Kvarh
Maximum average values (maximum demand) (I1avg, I2avg, I3avg, pavg , savg.)
Maximums instantaneous values (I, P, S)
Serial Output Rs485 (Prot. MODBUS RTU)
Auxiliary Supply
400 V 50-60Hz connecting to voltage inputs
230 V 50-60Hz (OPTION)
Protection Degree
IP 55 front, IP 20 enclosure
SIMS TRADERS 4
_______________________________________________________________________________________
Current Inputs
3 inputs 0,05÷5A rms program. Transf. ratio with external CT.
Measuring Accuracy
voltage:<0.5%, current :<0.5%
power:<1%, energy:<1%
Serial output
1 Rs485 baud rate 9600 bps
Communication Protocol, Modbus-Rtu
Displays
4 displays with10mm red LED’s (3 digits of 10mm 8 segments)
Mechanical Characteristics
DIN rail mounting (6 modules of 17,5mm weight 0,5 kg) (All other SPECS as per R4)
SIMS TRADERS 5
_______________________________________________________________________________________
Mechanical Characteristics
Flush mounting, DIN 96x96 mm, depth 55 mm
Panel cut out 92x92mm
Weight 0,5 kg
Measured Parameters
Current (L1, L2, L3, total)
Voltage V (L1, L2, L3, L12, L23, L31, total)
Frequency
Hours Counter
Maximums instantaneous values (I, V)
Average Values maximum (maximum demand) I1avg, I2avg, I3avg
Auxiliary Supply
400 V 50-60Hz connecting to voltage inputs
230 V 50-60Hz (OPTION)
Protection Degree
IP 55 front, IP 20 enclosure
Voltage Inputs
3 inputs 500 V max program. Transf. ratio with external VT.
Current Inputs
3 inputs 0,05÷5A rms program. Transf. ratio with external CT.
SIMS TRADERS 6
_______________________________________________________________________________________
Displays
4 displays with10mm red LED’s (3 digits of 10mm 8 segments)
Measured Parameters
Active Energy +Kwh
Reactive Energy +Kvarh
SIMS TRADERS 7
_______________________________________________________________________________________
SPECIFICATION
• POWER MEASUREMENT
Per phase: Phase voltage,Line voltage Current (per phase) 3 phase total: Hz, PF, KW, KVAR, Kwh,
Kvarh
• PF with lead and lag detection
• Bi directional KWH/KVARH
• Total harmonic distortion: per phase V and A
• Unbalance
• Each order harmonic ( 2-31THTHFF,CREST FACTOR:): available on communication PORT
• ACCURACY
Current and voltage: 0.5%Frequency(40-70Hz): 0.1Hz . Other power functions: 1%Harmonic:2%
• VOLTAGE INPUT: 600 VAC Max. L/L
• CURRENT INPUT 5 Amps with 20% over range
• 3 phase 3 wire and 3 phase 4 wire
The Crest Factor is equal to the peak amplitude of a waveform divided by the RMS value.
SIMS TRADERS 8
_______________________________________________________________________________________
SIMS TRADERS 9
_______________________________________________________________________________________
DEM500
DEM600
DEM620 DEM630
GENERAL SPECIFICATION
SIMS TRADERS 10
_______________________________________________________________________________________
SIMS TRADERS 11
_______________________________________________________________________________________
EPM420P
EPM420P 130,000/-
Meaurement function:
Each phase voltage and each phase current, 3 phases total of Hz,KW,KVAR,POWER FACTOR KWH,KVARH
Harmonic distorsion; (EPM425P only)
total harmonic,2-11th harmonic content for each phase voltage and current
SIMS TRADERS 12
_______________________________________________________________________________________
Data retrieve
Connect through Notebook RS232, automatic covert to ODBC or Excel format
SIMS TRADERS 13
_______________________________________________________________________________________
Thermostat
Thermostat Code: TRT-10A230V-NO 1,000/-
Description: Thermostat normally open
Setting temperature range: From -10°C to +80°C
Rated voltage range: 110 – 250 Va.c.
Type of load / Max rated current: Resistive load / 5 A
SIMS TRADERS 14
_______________________________________________________________________________________
SIMS TRADERS 15
_______________________________________________________________________________________