Formerly Conifloor C
A seamless, self smoothing and flexible, polyurethane based resin flooring system

DESCRIPTION TYPICAL PERFORMANCE DATA


MASTERTOP 1325 is a seamless, self smoothing, 7 days cure @ 20oC
flooring system based on an advanced solvent free Tensile strength (DIN 53504) : 35 N/mm2
polyurethane system. It has a smooth and seamless
surface that is easy to maintain in spotless hygienic Bond strength (DIN ISO 4624) : < 2.5 N/mm2
condition and exhibits excellent resistance to traffic and
Elongation (DIN 53504) : 160%
a wide range of chemicals. In addition, it reduces noise
and is comfortable to walk on. Shore D Hardness : 80
MASTERTOP 1325 is in compliance with:
Service Temperature : -20°C to 60°C
Type Cert. Institute Classification Remarks
no. Application Temperature : Minimum 10°C
Norm
: Maximum 35°C
Resistance P 702 DAR passed
to cigarette PROPERTIES
burns
OS 8 cert. P 702- DAR passed Burning a. Components
4 Supply Colour Density
FDH and P 896- DAR passed Federal form kg/L
FCH C Health Mastertop Primer 9 liquid amber 1.10
approval Centre
(Germany)
Part A

Noise DAR 4-7 db Mastertop Primer 9 liquid amber 1.05


reduction Part B
Crack DIN INE 530 Mastertop Body liquid coloured 1.30*
bridging 25541 Coat 32 Part A
5
Mastertop Body liquid amber
Coat 32 Part B
RECOMMENDED FOR Filler F1 solid white 2.6
MASTERTOP 1325 is recommended for floors where a
high level of aesthetics, combined with comfort and Filler F5 solid white 2.6
noise dampening, is essential. It is ideal for floors in:
• universities
• hospitals and other medical facilities Mastertop Top liquid coloured 1.0*
• offices Coat 44P Part A +
Part B
• cafeterias
• laboratories * Part A and Part B mixed

FEATURES AND BENEFITS b. Mixed systems


Mix ratio
Ergonomic Provides a pleasing motivating Components by weight
working environment.
High abrasion Lower maintenance costs. Mastertop Primer 9 # A:B 100:27
resistance Mastertop Body Coat A:B:F1 7:2:3
Easy to clean Allows floor surface to be 32
and sterilise maintained in a hygienic state.
Comfortable Assists in preventing foot ache and Mastertop Top Coat A:B 10:1
and flexible fatigue of staff. 44P
Noise reducing Avoids noise caused by foot traffic.

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® 1325
Pot-life (minutes) Premix one unit of Mastertop Primer 9 Part A with one
@ 10°C @ 20°C @ 30°C unit of Mastertop Primer 9 Part B for at least 3 minutes
until the mix is uniform and free of streaks.
Mastertop Primer 9 70 35 20 Placing
Immediately after mixing, pour the material onto the
Mastertop Body 60 30 20 substrate and spread the mixed material using a
Coat 31 squeegee or paint roller. The primary purpose of this
Mastertop Top 120 60 30 primer coat is to seal the substrate completely and avoid
Coat 44P air bubbles in the body coat. On very porous substrates,
a second primer / sealer coat may be required. If in
Curing time (days) doubt, apply a sample patch of body coat.
Broadcasting of sand
@ 10°C @ 20°C @ 30°C F 5 filler is broadcast at the rate of 0.8 to 1.0 kg/m2 onto
Mastertop Primer 9 5 2 1 the wet primer; do not sand in excess. Placing of the
body coat onto unsanded surfaces outside the recoating
Mastertop Body 7 3 2 interval will lead to interlayer failures (de-bonding).
Coat 32
BODY COAT
Mastertop Top 5 2 1 Mixing
Coat 44P Use a low speed (300 rpm) electric drill fitted with a paint
mixer or a wing type paddle (refer to the Tools data
Maximum permissible relative humidity sheet). Mix one unit of Mastertop Body Coat 32 Part A
with one unit Mastertop Body Coat 32 Part B and mix for
@ 10°C at >23°C
at least 3 minutes or until the mix is uniform in colour
All components 75 % 90 % and free of streaks. Continue to mix and add one bag of
F1 filler until a homogenous and uniform mix is obtained.
Placing
APPLICATION Depending on the substrate condition, apply 2.1 to 2.8
kg/m2 of the mix. Pour out the whole mix at once into
Surface Preparation
pours being approximately 200-300 mm wide, running
The compressive strength of the substrate shall not be
parallel to the work direction. Distribute and level the
less than 30 N/mm2. The substrates in contact with the
material with a notched trowel of the following dimension
ground must have a vapour barrier installed in
width/ height/ separation: 3/5/10 mm). Leave the placed
compliance with DIN 18195 or equivalent, or be primed
material for 10-15 minutes and de-aerate with a spike
with Mastertop Primer 9. The moisture content of the
roller
substrate shall not be higher than 8% throughout (check
Note: For a matt finish and maximum abrasion and UV
using with CM equipment). The temperature of the
resistance, seal with Mastertop Top Coat 44 P
substrate must be at least 3°C above the current dew
Following the application of the MASTERTOP 1325,
point temperature. Correct substrate preparation is
protect coated area for at least 24 hours after laying from
critical for optimum performance. Surfaces must be
spillage, dust, insects, small animals, traffic, rain,
structurally sound, clean, and free from loose particles,
moisture, etc.
oil, grease, and all other contaminants. Remove oil,
grease and wax contaminants by scrubbing with CLEANING
industrial grade detergent or degreasing compounds
followed by mechanical cleaning. Cement laitance, loose Clean tools and equipment first with paper towels or
particles, mould release agents, curing membrane and rags, then wipe using a solvent such acetone or
other contaminants must be removed from the surface methyliso-butyl ketone before the resin system hardens.
by shot blasting, Blastrac®, scarifying or gritblasting
followed by vacuum cleaning. ESTIMATING DATA
After pretreatment of the substrate, the bond strength of
the substrate must be at least 1.5 N/mm 2 (check with an For thickness of 2.0 to 2.5 mm
approved pull-off tester at load rate 100 N/s). Fill surface System Product kg/m2 Thickness
irregularities such as blowholes, cracks, honeycombs, mm
etc. with an EMACO® repair mortar to achieve a smooth
and level surface. Primer Mastertop 0.4 - 0.6 0.3 - 0.4
Protect walls and columns against resin splashes using Primer 9
masking tape and polythene sheeting. Broadcasting Filler F5 0.8 - 1.0 0.3 - 0.4
sand
PRIMER
Mixing Body coat Mastertop 2.1 – 2.8 1.5 – 2.0
Use a low speed (300 rpm) electric drill fitted with a paint Body Coat
mixer or a wing type paddle. 32 + Filler
F1
MASTERTOP® 1325
Abrasion Mastertop 0.1 - PRECAUTIONS
resistant sealer Top Coat
MASTERTOP 1325 contains certain chemicals which
matt 44 P
can cause skin irritation if exposed and respiratory
reaction if inhaled. Wear gloves, masks and use hand
PACKAGING barrier cream while handling the product. Wash
thoroughly after handling.
Mastertop Primer 9 30.0 kg/set Should skin contact occur, wash immediately with soap
Mastertop Body Coat 32 30.0 kg/set and water or an effective hand cleaner.
Filler F1 15.0 kg/bag In case of accidental eye contact, wash with copious
Filler F5 25.0 kg/bag quantity of water and immediately seek medical advice.
Mastertop Top Coat 44 P 10.0 kg/set If ingested, do not induce vomiting. Consult a doctor
immediately.
SHELF LIFE Vapours of solvents used for cleaning can be irritating. It
is therefore recommended that cleaning be done in
MASTERTOP 1325 can be kept for 12 months from date wellventilated areas.
of manufacture if stored in original unopened packaging, For detailed Health, Safety and Environmental
in a dry enclosed place, at temperatures between 15 to Recommendations, please consult and follow all
35°C, without exposing to direct sunlight. instructions on the product Material Safety Data Sheet.
Fire: Keep away from sources of ignition. Do not smoke
whilst handling the product.
Flash point: 110oC
MT 1325/04/0301

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.