Sei sulla pagina 1di 25

First incorporated in August of commitment to quality; quality of control, offer excellent product

1948, Wilkerson manufactures a products, services and people. knowledge, technical assistance
complete line of compressed air Our dedication to the total quality and local inventory. As a result of
treatment and control products to management process assures our representing other complimentary
meet a wide variety of industrial, customers that we can consistently products, they are able to satisfy
process, consumer and health provide the highest levels of product their customers’ total requirements.
care applications. Today, Wilkerson quality and customer service Today’s broad line of Wilkerson
serves over 500 different industries required to meet their needs. products is the result of
throughout the world. From the very beginning, Wilkerson continuing product innovations
Over the years, Wilkerson facilities, has sold its products through a and technology advancements
manufacturing and engineering world-wide, independent distributor which frequently become industry
technology have kept pace with network. We currently have 200 standards. Wilkerson is dedicated
increased sales volume, the growing distributors throughout North to designing and manufacturing
need to satisfy customers’ specific America, plus an expanding network innovative products with features
requirements and the demands of international distributors in over and operating characteristics that
placed on production. 40 countries. Our distributors, who meet customer requirements for
Wilkerson’s growing leadership in have many years of experience quality, performance, reliability,
the industry is due to our determined in compressed air treatment and serviceability, safety and value.

      !      WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN
OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from The Company, its subsidiaries and authorized distributors provide product and/or
system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your
application including consequences of any failure, and review the information concerning the product or system in the current
product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through
its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that
all performance, safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing,
are subject to change by The Company and its subsidiaries at any time without notice.

Offer of Sale
The items described in this document are hereby offered for sale by The Company, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated on the separate page of this
document “Offer of Sale”.

© Copyright 2011, 2008, 2003 Parker Hannifin Corporation. All Rights Reserved.
(Revised 4-10-2013)

Catalog 9EM-TK-190-3 Index

D
Modular Accessories and Repair Kits

Accessories & Repair Kits


Filter Replacement Element Kits..........D2 Accessories –
Filter Replacement Bowl Kits................D3 Filter / Regulators.......................D13-D15

Accessories – Filters.......................D4-D5 Accessories – 08 Series......................D16

Accessories – Regulators...............D6-D7 Accessories – 12 Series......................D17


Accessories – 18 / 28 Series...............D18
Regulator Replacement Kits.................D8
Accessories – 16 / 26 Series...............D19
Lubricator Replacement Kits................D9
Accessories – 39 Series......................D20
Accessories – Lubricators..........D10-D11
Filter / Regulator –
Replacement Repair Kits...................D12

D1 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter Accessories

Filter Replacement Element Kits

Type A Type B1 Type B Type C Type D


Model
5 Micron 1 Micron 0.5 Micron 0.01 Micron Oil Vapor Removing
Particulate Filters
F01 FRP-95-199 — — — —
F03 PS403 — — — —
F08 FRP-96-729 — — — —
F12 GRP-96-344 — — — —
F16 FRP-95-160 — — — —
F18 FRP-96-639 — — — —

D F26
F28
FRP-95-115
FRP-96-653








F30 FRP-95-209 — — — —
F34 FRP-95-209 — — — —
Accessories & Repair Kits

F35 FRP-95-505 — — — —
F36 FRP-95-506 — — — —
F37 FRP-95-507 — — — —
F39 P3NKA00ESE — — — —
F43 FRP-95-508 — — — —
F50 FRP-95-212 — — — —
F51 FRP-95-213 — — — —
F52 FRP-95-212 (3 kits) — — — —
F53 FRP-95-213 (3 kits) — — — —
Coalescing Filters
M03 — PS456 — PS446 PS452
M08 — — MSP-96-732 MTP-96-649 MXP-96-222
M12 — — MRP-96-301 MRP-96-300 FRP-96-301*
M16 — — MSP-95-988 MTP-95-548 MXP-95-987
M18 — — MSP-96-647 MTP-96-646 MXP-96-650
M21 — — MSP-96-649 MTP-96-648 MXP-96-651
M26 — — MSP-95-989 MTP-95-549 MXP-95-540
M28 — — MSP-96-649 MTP-96-648 MXP-96-651
M30 — — MSP-95-992 MTP-95-551 MXP-95-532
M31 — — MSP-95-993 MTP-95-521 MXP-95-522
M32 — MSP-95-873 — MTP-95-559 MXP-95-558
M35 — MSP-95-502 — MTP-95-502 MXP-95-502
M36 — MSP-95-503 — MTP-95-503 MXP-95-503
M37 — MSP-95-504 — MTP-95-504 MXP-95-504
M39 — — P3NKA00ES9 P3NKA00ESC —
M43 — MSP-95-876 — MTP-95-562 MXP-95-565
M45 — MSP-95-500 — MTP-95-500 MXP-95-500
* For F12 Series Filters.

D2 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter Accessories

Filter Replacement Bowl Kits

Plastic Bowl / Plastic Bowl / Metal Bowl / Plastic Bowl / Metal Bowl /
Bowl Guard / Plastic Bowl / Bowl Guard / Metal Bowl / Sight Gauge / Bowl Guard / Metal Bowl / Sight Gauge /
Model No Drain Manual Drain Manual Drain Manual Drain Manual Drain Automatic Drain Automatic Drain Automatic Drain
Particulate Filter / Coalescing Flter
F03 / M03 — PS404 — PS447B — — PS451B** —
F08 / M08 — — GRP-96-712 GRP-96-714* — — — —
GRP-96-347 GRP-96-351**
F12 / M12 — — GRP-96-348 GRP-96-349 GRP-96-353** GRP-96-352**
w/ GRP-96-345 w/ GRP-96-345
F18 / M18 GRP-96-638 — GRP-96-634 — GRP-96-636 GRP-96-635 — GRP-96-637
F16 / M16 — FRP-95-017 FRP-95-014 FRP-95-178 GRP-95-133 FRP-95-015 FRP-95-950 —
F28 / M28 GRP-96-652 — GRP-96-642 — GRP-96-644 GRP-96-643 — GRP-96-645
F26 / M26 — GRP-95-929 GRP-95-935 GRP-95-930 GRP-96-931 GRP-95-948 GRP-95-960 —
M21 — MRP-96-415 FRP-95-722 — — — — —
F39 / M39 — — — — P3NKA00BSM — — P3NKA00BSA D
F30 / M30 — FRP-96-315 FRP-95-832 FRP-95-593 GRP-95-676 FRP-95-77 GRP-95-970 —
F34 — — GRP-95-902 — — — — —
M31 — MRP-95-940 MRP-95-938 MRP-95-939 — MRP-95-941 — —

Accessories & Repair Kits


* Metal bowl does not have sight gauge.
** 12 Series has Piston Style Drain.

Bowl O-ring Bowl O-ring Filter Retainer Manual


Model
(Nitrile) (Fluorocarbon) Element Baffle Drain
Particulate Filter
F08 GRP-96-710 GRP-96-711 — —
F12 — — — GRP-96-340
F18 GRP-96-640 GRP-96-754 FRP-96-641 GRP-96-685
F28 GRP-96-654 GRP-96-755 FRP-96-283 GRP-96-685
F39 — — — PS512
Coalescing Filter
M08 GRP-96-710 GRP-96-711 — —
M12 — — — GRP-96-340
M18 GRP-96-640 GRP-96-754 — GRP-96-685
M28 GRP-96-654 GRP-96-755 — GRP-96-685
M30 — — — PS512

D3 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter Accessories

Accessories – Filters
A
A B
A B
B

C
C C

Differential Pressure Differential Pressure Differential Pressure


Indicator Indicator Indicator
DP2-01-000, DP2-01-001 DP8-01-000 FRP-96-300

C
B B

A
0.3
∆p 8

5 10
ps
0 i

C A

Cap, Differential Pressure Indicator Differential Pressure Gauge


GRP-95-020, GRP-95-022 DP3-01-000

D B

A
Accessories & Repair Kits

C
A

Use 3/8" C
or 10mm (Use with GRP-95-981 shown
Flex Tubing above. Order saperately)

Automatic Drain Piston Drain Manual Override for


GRP-95-973, GRP-95-981 GRP-96-716 Auto Float Drains
GRP-96-001

Dimensions Inches (mm)

Accessories Part Number Used On A B C


DP2-01-000 M16, M21, M26, M30, M31, M32
2.12 1.85 0.84
F35, F36, F37, F43, M35, (54) (47) (21)
Differential DP2-01-001
M36, M37, M43, M45
Pressure
F18, F28, 2.12 1.85 .84
Indicator DP8-01-000
M18, M28 (54) (47) (21)
1.25 1.50 .94
FRP-96-300 F12, M12
(31.8) (38.1) (23.8)
Cap, Differential GRP-95-020 M16, M21, M26, M30, M31, M32
Pressure Indicator 2.12 1.85 0.25
(Pressures over F35, F36, F37, F43, M35, (54) (47) (6.3)
GRP-95-022
150 PSIG, 10.3 bar) M36, M37, M43, M45
Differential 3.0 2.55 1.54
DP3-01-000 M32, M42
Pressure Gauge (75.9) (65) (39)
Automatic Drains,
GRP-95-973
Nitrile F18, M18, B18 F28, M28, B28 2.93 1.47 1.17
Automatic Drains, F16, F26, F30, F35, F36, F43 (74.4) (37.3) (29.7)
GRP-95-981
Fluorocarbon
Manual Override for — — —
GRP-96-001 GRP-95-981
Auto Float Drains
1.70 .94 .68
Piston Drain GRP-96-716 F08, M08, B08
(43) (24) (17)

D4 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter Accessories

Accessories – Filters B
A C
L C F
B
E
D D
A

G Dia.
J B E
K A F A B
D D E
F C
H
H
H G C
C-Bracket E
G
GPA-97-010
T-Bracket T-Bracket
C-Bracket GPA-96-602 GPA-96-737
F
G GPA-96-300 w/ Joiner

B H B H
B
C C
A E E
D D
J J
C D

G G
A F K Dia. A F K Dia.

L-Bracket
P3NKA00MW
L-Bracket
GPA-96-604
L-Bracket
GPA-96-605 D
For 1-1/2" BSPP Port Block with E02 fitting application,
use Mounting Bracket Kit P3NKA0BMW

Accessories & Repair Kits


B
F
D G
K Typ. C B
J
H D E
A
C F A
F

M
L

L-Bracket
GPA-95-016, GPA-95-946
L-Bracket
Dimensions Inches (mm) PS417B

Accessories Part Number Used On A B C D E F G H J K L M


2.67 1.73 1.57 .07 .39 1.57 .78 2.32 1.37 2.41 .26
GPA-97-010 F08, M08, B08 —
(68) (44) (40) (1.8) (9.9) (40) (20) (59) (35) (61) (6.6)
C-Bracket
.28 2.12 2.00 .14 1.85 .63 .28 1.41
GPA-96-300 F12, M12 — — — —
(7) (54) (51) (4) (47) (16) (7) (36)
2.12 3.62 3.40 2.53 1.88 1.60
GPA-95-016 F16, M16
(53) (91) (83) (64) (47) (41)
— — — — — —
2.12 3.62 3.80 2.93 1.88 1.60
GPA-95-946 F26, M26
(53) (91) (96) (74) (47) (41)
2.84 2.74 1.66 .38 .54 1.26 .88 .28 1.10 2.25
GPA-96-604 F18, M18, B18 — —
(72) (69.5) (42) (9.6) (14) (32) (22) (7.1) (28) (57)
L-Bracket
3.44 3.00 1.88 .38 .56 1.49 1.10 .28 1.10 2.66
GPA-96-605 F28, M28, B28 — —
(87) (76) (48) (9.6) (14) (38) (28) (7.1) (28) (67.5)
6.22 8.19 2.75 1.97 2.36 1.77 1.30
P3NKA00MW F39, B39 — — — — —
(158) (208) (70) (50) (60) (45) (33)
2.12 3.62 3.40 2.53 1.88 0.50 0.20 1.24 0.56 0.22 0.45 0.62
PS417B F03, M03
(53) (91) (83) (64) (47) (13) (5) (31) (14) (6) (11) (16)
F18, F28, 3.75 1.25 .76 .25 .28
T-Bracket GPA-96-602 — — — — — — —
M18, M28 (95) (32) (19.3) (6.3) (7.1)
T-Bracket .45 .28 .40 .67 3.97 .22 .40 .64
GPA-96-737 F08, M08 — — — —
w/ Joiner (11) (7.1) (10) (17) (100.8) (5.6) (10) (16)

D5 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Regulator Accessories

Accessories – Regulators B

60
A
A

40
2
4
6 C
B

20
8

11 10
bar
psi
160

Gauges Flush Mount Gauge


08 Series

Tamper
Resistant
D Ring

A C Pressure Dial
Stop Washer to
Lock Dial In Place
E

Wall Mounting Bracket


U-Bolt Pipe Clamp
GRP-95-734 RPA-95-006 RRP-95-585
Tamper Resistant Kit
D
Dimensions Inches (mm)

Accessories Used On A B C D E
K4515N14030 (0 to 30 PSIG) R12, R18, R28
Accessories & Repair Kits

K4515N14060 (0 to 60 PSIG) R12, R18, R28


K4515N14160 (0 to 160 PSIG) R12, R18, R28

Gauges, K4515N14300 (0 to 300 PSIG) R12, R18, R28 1.64 1.09 .80
— —
1/4 Port, CBM K4515G14030 (0 to 2.0 bar) R18, R28 (41.6) (27.6) (20)

K4515G14060 (0 to 4.2 bar) R18, R28


K4515G14160 (0 to 11 bar) R18, R28
K4515G14290 (0 to 20 bar) R18, R28
K4515N18030 (0 to 30 PSIG) R03
Gauges, 1.64 1.09 .80
K4515N18060 (0 to 60 PSIG) R03, RB3, R08 — —
1/8 Port, CBM (41.6) (27.6) (20)
K4515N18160 (0 to 160 PSIG) R03, RB3, R08
K4520N18030 (0 to 30 PSIG) P15, P16
K4520N14030 (0 to 30 PSIG R39
Gauges, 1.96 108 .91
K4520N14060 (0 to 60 PSIG) R31, R39, R41 — —
1/4 Port, CBM (49.8) (27) (23)
K4520N14160 (0 to 160 PSIG) R30, R31, R39, R40, R41
K4520N14300 (0 to 300 PSIG) R30, R39, R40
K4520N14060W (0 to 60 PSIG) R16, R26, P15, P161
Gauges, 1.96 108 .91
K4520N14160W (0 to 160 PSIG) R16, R26, P15, P16 — —
1/4 Port, CBM (49.8) (27) (23)
K4520N14300W (0 to 300 PSIG) R16, R26
K4511SCR150 (0 to 150 PSIG) R08
Flush Mount 1.06 .63
K4511SCR060 (0 to 60 PSIG) R08 — — —
Series Gauges (26.9) (16)
K4511SCR11B (0 to 11 bar) R08

Tamper Resistant RPA-95-006 R16, R26, P15, P16


— — — — —
Kit RRP-95-585 R11, R21, R31, R41
Wall Mtg. Bracket For All Non-Modular Units 3.34 2.76 1.62 1.10 0.30
GRP-95-734
U-Bolt Pipe Clamp Up to 1" NPT (85) (70) (41) (28) (7.6)

D6 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 (Revised 04-10-13) Regulator Accessories

Accessories – Regulators
A
B B
B F F
A E
C D
B C C
E E
J Dia. J Dia.
F D D
G
C H H
E G G
F
D A A
G

L-Bracket L-Bracket L-Bracket L-Bracket


GPA-95-011, GPA-95-012 GRP-95-147 GRP-96-606 GRP-96-607
E
B
F F
E D G G

J K Typ.
E
H
B A
F A C F
G
B
C M A
L
D
C D

L-Bracket L-Bracket L-Bracket


GPA-96-313 PS417B P3NKA00MW
(Includes Panel Mount Nut) For 1-1/2" BSPP Port Block with E02 fitting application,

B
use Mounting Bracket Kit P3NKA0BMW
B
D
C A B
E Dia.
D D
A

Accessories & Repair Kits


C A C

L-Bracket Wall Mounting Bracket – E


GRP-96-739 Gauge Port Adapter
RRP-95-590, 1/4" Pipe Thread
Wall Mounting Bracket U-Bolt Pipe Clamp
RRP-95-591, 1/8" Pipe Thread
GRP-95-734
Dimensions Inches (mm)

Accessories Used On A B C D E F G H J K L M
2.50 1.60 1.50 0.46 0.62 1.88 1.62
GPA-95-011 R16, P15, P16 — — — — —
L-Bracket with (63.5) (41) (38) (12) (16) (48) (41)
Plastic Panel Nut 1.50 0.68 1.00 1.75 0.34 0.31 0.22
GRP-95-747 RB3, RA3 — — — — —
(38) (17) (25) (44) (8.6) (7.9) (5.6)
2.50 1.60 1.50 0.46 0.62 1.88 1.62
GPA-95-012 R16, P15, P16
(63.5) (41) (38) (12) (16) (48) (41)
— — — — —

1.50 0.68 1.00 1.75 0.34 0.31 0.22


GRP-95-147 RB3, RA3 — — — — —
(38) (17) (25) (44) (8.6) (7.9) (5.6)
3.00 2.06 0.55 3.50 4.05 1.88
GPA-95-956 R26 — — — — — —
(76.2) (50.8) (14.0) (88.9) (102.9) (47.8)
.84 2.59 .49 1.02 1.85 .61 .28
GPA-96-313 R12 — — — — —
(21) (66) (12) (26) (47) (15) (7)
1.57 2.68 1.74 .97 1.19
L-Bracket GRP-96-739 R08, R09 — — — — — — —
(40) (68) (44) (25) (30)
2.74 2.74 1.66 .43 .54 .28 1.57 1.00 2.0
GPA-96-606 R18, R19 — — —
(69.5) (69.5) (42) (11) (14) (7.1) (40) (25) (51)
3.33 3.00 1.88 .43 .56 2.40 1.94 1.00 2.40
GPA-96-607 R28 — — —
(84.5) (76) (48) (11) (14) (61) (49) (25) (61)
6.22 8.19 2.75 1.97 2.36 1.77 1.30
P3NKA00MW R39 — — — — —
(158) (208) (70) (50) (60) (45) (33)
1.80 2.37 0.90 1.35 1.00 0.50 0.20 1.24 0.56 0.22 0.45 0.62
PS417B R03
(46) (60) (23) (34) (25) (13) (5) (31) (14) (6) (11) (16)
P15, P16, R16,
1.87 1.38 1.25
Wall Mtg. Bracket RRP-95-590 R21, R26, R30, — — — — — — — — —
(47.5) (35) (31.7)
Gauge Port R31, R40, R41
Adapter 1.87 1.38 1.09
RRP-95-591 RB3, RA3, R03 — — — — — — — — —
(47.5) (35) (27.6)

D7 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Regulator Accessories

Regulator Replacement Kits


Self-relieving Non-relieving
Diaphragm Diaphragm Valve Tamper Plastic Aluminum
Model (Nitrile) (Nitrile) Assembly Kit Resistant Ring Panel Nut Panel Nut
R08, R09 GRP-96-725 GRP-96-726 RRP-96-727 RPA-96-735 RPA-96-734 RPA-96-733
R12 RRP-96-306 RRP-96-307 N/A N/A N/A GPA-96-314
R18 RRP-96-656 RRP-96-657 RRP-96-658 RRP-96-671 RRP-96-675 RRP-96-673
R19 RRP-96-760 RRP-96-761 RRP-96-658 RRP-96-671 RRP-96-675 RRP-96-673
R28 RRP-96-986 RRP-96-987 RRP-96-049 RRP-96-672 RRP-96-676 RRP-96-674
Main Regulating Main Regulating Main Regulating Main Regulating
Spring Spring Spring Spring
Model 0-30 PSIG 0-60 PSIG 0-125 PSIG 0-250 PSIG
R08, R09 GRP-95-111 GRP-96-718 GRP-96-717 N/A
R12 RRP-96-303 RRP-96-302 RRP-96-301 N/A
R18, R19 RRP-96-659 RRP-96-660 RRP-96-661 RRP-96-662
R28 RRP-96-163 RRP-96-164 RRP-96-165 RRP-96-166
R39 N/A C10A1304 CA101308 CA101317

D
Model Self-relieving Non-relieving Self-relieving Non-relieving Repair Kit Repair Kit Valve
Regulator Piston Piston Diaphragm Diaphragm Self-relieving Non-relieving Assembly Kit
R03 — — — — PS423 PS422 PS424B
Accessories & Repair Kits

R16 — — RRP-96-213 RRP-96-216 RRP-95-130 RRP-95-129 RRP-96-215


R21 — — — — RRP-95-151 — —
R26 — — RRP-96-238 RRP-96-332 RRP-95-951 RRP-95-950 RRP-96-294
R30 — RRP-95-451 — — — — RRP-95-159
R31 RRP-95-192 — — — RRP-95-152 — RRP-96-935
R40 — RRP-95-451 — — RRP-95-161 RRP-95-162 —
R41 RRP-95-192 — — — — — RRP-96-935

Fluorocarbon Fluorocarbon
Self-relieving Non-relieving Repair Kit Repair Kit Valve Diaphragm Valve
Model Diaphragm Diaphragm Self-relieving Non-relieving Assembly Kit Self-relieving Assembly
Precision
Regulator PRP-95-960 — PRP-95-004 PRP-95-053 PRP-95-959 PRP-95-073 PPA-95-067
P15 / P16

Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure Pressure


Spring Spring Spring Spring Spring Spring Spring Spring Spring
0-15 PSIG 0-30 PSIG 0-40 PSIG 0-50 PSIG 0-60 PSIG 0-125 PSIG 0-160 PSIG 0-180 PSIG 0-250 PSIG
R16 — — — RRP-95-222 — RRP-95-224 — — RRP-95-218
R21 — — RRP-95-906 — — — RRP-95-905 — —
R26 — — — — RRP-95-962 GRP-95-225 — — RRP-95-219
R30 — — — — — RRP-95-226 — RRP-95-220 —
R31 — — RRP-95-906 — — — RRP-95-905 — —
R40 — — — — — RRP-95-226 — RRP-95-220 —
R41 — — RRP-95-906 — — — RRP-95-905 — —
P15 / P16 RRP-95-233 RRP-95-916 — RRP-95-222 — RRP-95-224 — — —

D8 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Lubricator Accessories

Lubricator Replacement Bowl Kits

Plastic Bowl / Metal Bowl /


Manual Drain
Plastic Bowl Bowl Guard Plastic Bowl Sight Gauge
Kit
Model No Drain Port Manual Drain Petcock Drain Manual Drain
L03 — PS421 — — —
L16 — LRP-96-937 — LRP-96-543 GRP-95-133
L08 — — LRP-96-736 — GRP-96-714*
LRP-96-308**
L12 GRP-96-340 — — LRP-96-306
w/ GRP-96-345
L17 — LRP-96-937 — LRP-96-543 GRP-95-133
L18 GRP-96-685 — LRP-96-701 — GRP-96-636
L26 — LRP-95-938 LRP-95-967 LRP-95-958 GRP-95-931 D
L27 — LRP-95-938 LRP-95-967 LRP-95-958 GRP-95-931
L28 GRP-96-685 — LRP-96-702 — GRP-96-644
L30 — LRP-96-940 LRP-95-830 LRP-96-160 GRP-95-676

Accessories & Repair Kits


L34 — LRP-96-940 LRP-95-830 LRP-96-160 GRP-95-676
L39 PS512 — ­— — P3NKA00BSM
L40 — LRP-96-940 LRP-95-830 LRP-96-160 GRP-95-676
L50 — LRP-96-940 LRP-95-830 LRP-96-160 GRP-95-676
*Metal bowl does not have sight gauge. ** No Drain.

Lubricator Replacement Kits


Fill Plug Kit
Siphon Tube Bowl O-ring Bowl O-ring Force Fill (Fill Plug & Sight Dome
Model Assembly (Nitrile) (Fluorocarbon) Adapter O-ring) Assembly
L08 LRP-96-731 GRP-96-710 GRP-96-711 N/A LRP-96-730 LRP-96-301
L12 N/A N/A N/A LRP-96-302 N/A N/A
L18 LRP-96-677 GRP-96-640 GRP-96-754 LRP-96-704 LRP-96-679 LRP-96-310
L28 LRP-96-781 GRP-96-654 GRP-96-755 LRP-96-704 LRP-96-679 LRP-96-310
L39 N/A N/A N/A P3NKA00PK P3NKA00PL PS740

Force Fill Adapter


(Optional – Replaces Fill Plug)

D9 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Lubricator Accessories

Accessories – Lubricators
Dummy
Force-Fill Adapter Adjustment
Screw

Real
Adjustment
Screw

Force Fill Adapter Tamper Resistant Kit


GRP-96-394 LRP-95-587

F442 Oil
F442001 - 1 Quart Bottle
F442002 - 1 Gallon
F442005 - 4 Gallon Case

Auto-Fill™ Adapter Kits Offset


Siphon Two or More Lubricators
Tube
These adapters provide automatic oil replenishing to several Air Flow

D lubricators from a central oil supply. See schematic for


installation. Pump, regulators, shut-off valves not included.
Regulator
Shut
Off
Valve
Oil supply pressure must be a least 5 PSIG (0.3 bar) above
compressed air pressure at lubricators, but no higher than Oil
Supply
Oil
Oil Level Supply
50 PSIG (3.4 bar) above. Oil pressure must be turned off Float Ports Line
when air pressure is turned off. Control
Accessories & Repair Kits

Air Trans Pump


Pressure
Oil Gauge
Supply
Port
Order Part No. LRP-95-965 to adapt L26, L27, Regulator
and No. LRP-95-698 for L30 and L34 series.
Central
Oil
Supply

Dimensions Inches (mm)

Accessories Part Number Used On A B C D E F G H J K L M


L16 / L17, L26 / L27,
Force-Fill
GRP-96-394 L30, L31, L32, L34, — — — — — — — — — — — —
Adapter
L50
L16 / L17, L26 / L27,
Tamper
LRP-95-587 L30, L31, L32, L34, — — — — — — — — — — — —
Resistant Kit
L40, L41, L42, L50
F442001 – 1 Quart Bottle
Oil F442002 – 1 Gallon — — — — — — — — — — — —
F442005 – 4 Gallon Case

D10 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Lubricator Accessories

Accessories – Lubricators
B
A
L
B B
E A F
D E
D G Dia.
J C
A C K H G
D
E F C
H

Wall Mounting Bracket C-Bracket C-Bracket


U-Bolt Pipe Clamp GPA-97-010 GPA-96-300
GRP-95-734

C B
D E B H B H
C C
E E
A
F D D
J J

G G
A F K Dia. A F K Dia.

L-Bracket L-Bracket L-Bracket


GPA-95-016, GPA-95-946 GPA-96-604 GPA-96-605 D
F
G
E
B F

Accessories & Repair Kits


E D G

J K Typ.
H
A
B
A C F

C D
M
L

L-Bracket
P3NKA00MW
For 1-1/2" BSPP Port Block with E02 fitting application,
use Mounting Bracket Kit P3NKA0BMW
L-Bracket
PS419
Dimensions Inches (mm)

Accessories Part Number Used On A B C D E F G H J K L M


Wall Mounting For All Non-Modular 3.34 2.76 1.62 1.10 0.30
GRP-95-734 — — — — — — —
Bracket Units Up To 1" NPT (85) (70) (41) (28) (7.6)
2.67 1.73 1.57 .07 .39 1.57 .78 2.32 1.37 2.41 .26
GPA-97-010 L08 —
(68) (44) (40) (1.8) (9.9) (40) (20) (59) (35) (61) (6.6)
C-Bracket
.28 2.12 2.00 .14 1.85 .63 .28 1.41
GPA-96-300 L12
(36)
— — — —
(7) (54) (51) (4) (47) (16) (7)
2.12 3.62 3.40 2.53 1.88 2.12
GPA-95-016 L16 / L17 — — — — — —
(53) (91) (83) (64) (47) (54)
2.12 3.62 3.80 2.93 1.88 2.12
GPA-95-946 L26 / L27 — — — — — —
(53) (91) (96) (74) (47) (54)
2.84 2.74 1.66 .38 .54 1.26 .88 .28 1.10 2.25
GPA-96-604 L18 — —
(72) (69.5) (42) (9.6) (14) (32) (22) (7.1) (28) (57)
L-Bracket
3.44 3.00 1.88 .38 .56 1.49 1.10 .28 1.10 2.66
GPA-96-605 L28 — —
(87) (76) (48) (9.6) (14) (38) (28) (7.1) (28) (67.5)
6.22 8.19 2.75 1.97 2.36 1.77 1.30
P3NKA00MW L39 — — — — —
(158) (208) (70) (50) (60) (45) (33)
2.12 3.62 3.40 2.53 1.88 0.50 0.20 1.24 0.56 0.22 0.45 0.62
PS419 L03
(53) (91) (83) (64) (47) (13) (5) (31) (14) (6) (11) (16)

D11 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter / Regulator Accessories

Filter / Regulators Replacement


Repair Kits

Plastic Bowl / Metal Bowl / Plastic Bowl / Metal Bowl / Plastic Bowl /
Bowl Guard Sight Gauge Bowl Guard Sight Gauge Bowl Guard
Model Manual Drain Manual Drain Automatic Drain Automatic Drain Closed Bottom
B08 GRP-96-712 GRP-96-714* N/A N/A N/A
GRP-96-347 GRP-96-351**
B12 GRP-96-349 GRP-96-352** N/A
w/ GRP-96-345 w/ GRP-96-345
B18 GRP-96-634 GRP-96-636 GRP-96-635 GRP-96-637 GRP-96-638

D B28
B39
GRP-96-642
N/A
GRP-96-644
P3NKA00BSM
GRP-96-643
N/A
GRP-96-645
P3NKA00BSA
GRP-96-652
N/A
* Metal bowl does not have sight gauge.
** 12 Series has Piston Style Drain.
Bowl Bowl
Accessories & Repair Kits

Filter Element O-ring O-ring Filter Retainer Manual


Model 5 Micron (Nitrile) (Fluorocarbon) Element Baffle Drain
B08 FRP-96-729 GRP-96-710 GRP-96-711 N/A N/A
B12 GRP-96-344 N/A N/A N/A GRP-96-340
B18 FRP-96-639 GRP-96-640 GRP-96-754 FRP-96-641 GRP-96-685
B28 FRP-96-653 GRP-96-654 GRP-96-755 FRP-96-283 GRP-96-685
B39 P3NKA00ESE N/A N/A N/A PS512
Self-relieving Non-relieving Valve Valve Service Kit
Model Diaphragm (Nitrile) Diaphragm (Nitrile) Assembly Kit Spring (Relieving)
B08 GRP-96-725 GRP-96-726 RRP-96-727 RRP-96-728 N/A
B12 RRP-96-306 RRP-96-307 N/A N/A RRP-96-306
B18 RRP-96-656 RRP-96-657 RRP-96-658 N/A N/A
B28 RRP-96-986 RRP-96-987 RRP-96-049 N/A N/A
Main Regulating Main Regulating Main Regulating Main Regulating
Spring Spring Spring Spring
Model 0-30 PSIG 0-60 PSIG 0-125 PSIG 0-250 PSIG
B08 GRP-95-111 GRP-96-718 GRP-96-717 N/A
RRP-96-304
B12 RRP-96-303 RRR-96-302 RRP-96-301
(200 PSIG)
B18 RRP-96-659 RRP-96-660 RRP-96-661 RRP-96-662
B28 RRP-96-163 RRP-96-164 RRP-96-165 RRP-96-166
B39 N/A C10A1304 CA101308 CA101317
Tamper Resistant Aluminum Plastic Manual
Model Resistant Ring Panel Nut Panel Nut
B08 RPA-95-735 RPA-96-733 RPA-96-734
B12 N/A N/A GPA-96-314
B18 RRP-96-671 RRP-96-673 RRP-96-675
B28 RRP-96-672 RRP-96-674 RRP-96-676

D12 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter / Regulator Accessories

Accessories Filter / Regulators


B B
Tamper
Resistant
Ring

A
A
C

Use 3/8" C
or 10mm
Flex Tubing

Automatic Drain Piston Drain Tamper Resistant Kit


GRP-95-973, GRP-95-981 GRP-96-716 RPA-95-006

60 A
A
40

2
4
6 C
B
20

11 10
bar
ps
i 160

B
Gauges Flush Mount Gauge
08 Series

D A B

A C

D
C

Wall Mounting Bracket Wall Mounting Bracket –


U-Bolt Pipe Clamp Gauge Port Adapter
GRP-95-734 RRP-95-590
Dimensions Inches (mm)

Accessories Part Number Used On A B C D E

Accessories & Repair Kits


Automatic Drains,
GRP-95-973 B18, B28, CB6
Nitrile 2.93 1.47 1.17
— —
Automatic Drains, (74.4) (37.3) (29.7)
GRP-95-981 B18, B28, CB6
Fluorocarbon
1.70 .94 .68
Piston Drain GRP-96-716 B08 — —
(43) (24) (17)
K4515N18030 (0 to 30 PSIG) B03
Gauges, 1.64 1.09 .80
K4515N18060 (0 to 60 PSIG) B03, BB3, BA3 — —
1/8 Port, CBM (41.6) (27.6) (20)
K4515N18160 (0 to 160 PSIG) B03, BB3, BA3
K4520N18030W (0 to 30 PSIG) PC5, PC6

Gauges, K4520N14060W (0 to 60 PSIG) CB6, PC5, PC6 1.96 108 .91


— —
1/4 Port, CBM K4520N14160W (0 to 160 PSIG) CB6, PC5, PC6 (49.8) (27) (23)

K4520N14300W (0 to 300 PSIG) CB6


K4515N14060 (0 to 60 PSIG) B12, B18, B28
K4515N14160 (0 to 160 PSIG) B12, B18, B28

Gauges, K4515N14300 (0 to 300 PSIG) B12, B18, B28 1.64 1.09 .80
— —
1/4 Port, CBM K4515G14030 (0 to 2,0 bar) B12, B18, B28 (41.6) (27.6) (20)

K4515G14160 (0 to 11 bar) B18, B28


K4515G14290 (0 to 20 bar) B18, B28
K4511SCR150 (0 to 150 PSIG) B08
Flush Mount 1.06 .63
K4511SCR060 (0 to 60 PSIG) B08 — — —
Series Gauges (26.9) (16)
K4511SCR11B (0 to 11 bar) B08
Tamper Resistant Kit RPA-95-006 CB6, PC5, PC6 — — — — —
Wall Mtg. Bracket For All Non-Modular Units 3.34 2.76 1.62 1.10 0.30
GRP-95-734
U-Bolt Pipe Clamp Up to 1" NPT (85) (70) (41) (28) (7.6)
Wall Mtg. Bracket 1.87 1.36 1.06
RRP-95-590 CB6, PC5, PC6 — —
Gauge Port Adapter (47.5) (34.5) (27)

D13 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter / Regulator Accessories

Accessories – Filter / Regulators


E
B
F
D G
A
J K Typ.
H B
A C D
C F E
A
B
M
L F
G E
C F

D G

L-Bracket L-Bracket L-Bracket


PS417B GRP-95-147 GPA-95-011, GPA-95-012
(Includes Panel Mount Nut)

D
B H H
C C
E E
D D
J J

G G
A F K Dia. A F K Dia.
Accessories & Repair Kits

Body L-Bracket Body L-Bracket


GPA-96-604 GPA-96-605

B F B F
B C C
C E E
J Dia. J Dia.
D D
E Dia.
H H
D G G
A A A

L-Bracket Bonnet L-Bracket Bonnet L-Bracket


GRP-96-739 GRP-96-606 GRP-96-607

B B
F A A F
G D E

C
D H C
G

L-Bracket C-Bracket
GPA-96-313 GPA-96-300

D14 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Filter / Regulator Accessories

Accessories – Filter / Regulators F


G

B
A

C D

L-Bracket
P3NKA00MW
For 1-1/2" BSPP Port Block with E02 fitting application,
use Mounting Bracket Kit P3NKA0BMW B
C
C F
D D
A

E
A B

H
E
G

T-Bracket T-Bracket
GPA-96-737
D
GPA-96-602
w/ Joiner
Dimensions Inches (mm)

Accessories Part Number Used On A B C D E F G H J K L M

Accessories & Repair Kits


2.50 1.60 1.50 0.46 0.62 1.88 1.62
GPA-95-011 CB6, PC5, PC6
(63.5) (41) (38) (12) (16) (48) (41)
— — — — —
L-Bracket with
Plastic Panel Nut 1.50 0.68 1.00 1.75 0.34 0.31 0.22
GRP-95-747 BB3, BA3 — — — — —
(38) (17) (25) (44) (8.6) (7.9) (5.6)
2.50 1.60 1.50 0.46 0.62 1.88 1.62
GPA-95-012 CB6, PC5, PC6
(63.5) (41) (38) (12) (16) (48) (41)
— — — — —

1.50 0.68 1.00 1.75 0.34 0.31 0.22


GRP-95-147 BB3, BA3 — — — — —
(38) (17) (25) (44) (8.6) (7.9) (5.6)
.84 2.59 .49 1.02 1.85 .61 .28
GPA-96-313 R12 — — — — —
(21) (66) (12) (26) (47) (15) (7)
2.74 2.74 1.66 .43 .54 .28 1.57 1.00 2.0
GPA-96-606 B18 — — —
(69.5) (69.5) (42) (11) (14) (7.1) (40) (25) (51)
L-Bracket
3.33 3.00 1.88 .43 .56 2.40 1.94 1.00 2.40
GPA-96-607 B28 — — —
(84.5) (76) (48) (11) (14) (61) (49) (25) (61)
1.57 2.68 1.74 .97 1.19
GRP-96-739 B08 — — — — — — —
(40) (68) (44) (25) (30)
6.22 8.19 2.75 1.97 2.36 1.77 1.30
P3NKA00MW L39 — — — — —
(158) (208) (70) (50) (60) (45) (33)
2.12 3.62 3.40 2.53 1.88 0.50 0.20 1.24 0.56 0.22 0.45 0.62
PS417B B03
(53) (91) (83) (64) (47) (13) (5) (31) (14) (6) (11) (16)
.28 2.12 2.00 .14 1.85 .63 .28 1.41
GPA-96-300 B12 — — — —
(7) (54) (51) (4) (47) (16) (7) (36)
2.84 2.74 1.66 .38 .54 1.26 .88 .28 1.10 2.25
GPA-96-604 B18 — —
(72) (69.5) (42) (9.6) (14) (32) (22) (7.1) (28) (57)
C-Bracket
3.44 3.00 1.88 .38 .56 1.49 1.10 .28 1.10 2.66
GPA-96-605 B28 — —
(87) (76) (48) (9.6) (14) (38) (28) (7.1) (28) (67.5)
2.67 1.73 1.57 .07 .39 1.57 .78 2.32 1.37 2.41 .26
GPA-97-010 B08 —
(68) (44) (40) (1.8) (9.9) (40) (20) (59) (35) (61) (6.6)
3.75 1.25 .76 .25 .28
T-Bracket GPA-96-602 B18, B28 — — — — — — —
(95) (32) (19.3) (6.3) (7.1)
T-Bracket w/ .45 .28 .40 .67 3.97 .22 .40 .64
GPA-96-737 B08 — — — —
Joiner (11) (7.1) (10) (17) (100.8) (5.6) (10) (16)

D15 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Modular Accessories

Modular Accessories – 08 Series


B
C
F
D
A B

D E
A
A

C C
H
B
G

End Block Set End Block Set T-Bracket Joiner Set


w/ T-Bracket GPA-96-737 GPA-96-738
w/ Joiner (O-ring not shown)

Dimensions Inches (mm)

Accessories Part Number Pipe Size A B C D E F G H J K


T-Bracket .45 .28 .40 .67 3.97 .22 .40 .64
GPA-96-737 — — —
Joiner Set (11) (7.1) (10) (17) (100.8) (5.6) (10) (16)
D Joiner Set GPA-96-738 —
1.42 .39 .98
— — — — — — —
(36) (9.9) (26)
GPA-97-018 1/8 NPT
GPA-97-019 1/4 NPT
Accessories & Repair Kits

GPA-97-020 3/8 NPT 1.42 1.57 .53 .31


End Block Set — — — — — —
GPA-97-066 G 1/8 (36) (40) (13.5) (8)

GPA-97-067 G 1/4
GPA-97-065 G 3/8
GPA-97-025 1/8 NPT
GPA-97-026 1/4 NPT
End Block Set GPA-97-027 3/8 NPT 1.42 1.57 .53 .31
— — — — — —
With T-Brackets GPA-97-068 G 1/8 (36) (40) (13.5) (8)

GPA-97-069 G 1/4
GPA-97-070 G 3/8

D16 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Modular Accessories

Modular Accessories – 12 Series


C
.14 (4) K B
Typ.
G
J
.28 (7) F
Typ.
E
D H A
1.65 (42)
Dia.Thru
2 Places

.22 (6)
.43 (11) Typ.
Typ.

T-Bracket T-Bracket with Joiner Set


GPA-96-311 GPA-96-312

D
Joiner Set
GPA-96-310

End Block Set 12 Series

Accessories & Repair Kits


Dimensions Inches (mm)

Accessories Part Number Pipe Size A B C D E F G H J K


3.15 0.63 0.63 2.87 2.28 1.41 0.28 1.14 0.85 0.31
T-Bracket GPA-96-311 —
(80) (16) (16) (73) (56) (36) (7) (29) (22) (8)
T-Bracket w/
GPA-96-312 — — — — — — — — — — —
Joiner Set
Joiner Set GPA-96-310 — — — — — — — — — — —
GPA-96-301 1/8 NPT
GPA-96-302 1/4 NPT
GPA-96-303 3/8 NPT
GPA-96-304 G1/8
End Block Set GPA-96-305 G 1/4 — — — — — — — — — —
(Contains 2 End Blocks)
GPA-96-306 G 3/8
GPA-96-307 Rc 1/8
GPA-96-308 Rc 1/4
GRP-96-309 Rc 3/8

D17 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Modular Accessories

Modular Accessories – 18 / 28 Series

A A

O-ring O-ring

O-ring B Dia. O-ring B Dia. A

T-Bracket w/ Joiner Set GPA-96-603 Joiner Set GPA-96-601 End Block

Dimensions Inches (mm)

Accessories Part Number Pipe Size A B C D E F G H J K


T-Bracket w/ .35 .87
GPA-96-603 — — — — — — — — —
Joiner Set (8.9) (22.1)
D Joiner Set GPA-96-601 —
.35 .87
— — — — — — — —
(8.9) (22.1)
GPA-96-610 1/4 NPT
GPA-96-611 3/8 NPT
Accessories & Repair Kits

GPA-96-612 1/2 NPT


GPA-96-613 3/4 NPT 1.59
End Block — — — — — — — — —
GPA-96-620 G 1/4 (40)

GPA-96-621 G 3/8
GPA-96-622 G 1/2
GPA-96-623 G 3/4

D18 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 (Revised 08-23-11) Modular Accessories

Modular Accessories – 16 / 26 Series


B
C C D
B
C C
B

A D E
A A

A
B
E

Modular Pipe Adapter Modular Sleeve Modular Sleeve with T-Bracket Modular Manifold Block
GPA-95-035, GPA-95-292 GPA-95-969 (3 Auxiliary Ports)
GPA-95-036, GPA-95-919
GPA-95-037

B
C
E

A
B
C D
G
A D
A
C
B F

Accessories & Repair Kits


Modular 3-Way Shut-off Valve Right-Angle Bracket Modular Connecting
GPA-95-096, GPA-95-042 End Block Set
GPA-95-097, GPA-95-223, –224,
GPA-95-098 –225, –320, –321

Dimensions Inches (mm)

Pipe Size
Accessories Part Number A B C D E F G
NPT
GPA-95-035 1/4
1.25 1.25 1.14
Modular Pipe Adapter GPA-95-036 3/8 — — — —
(31.7) (31.7) (28.9)
GPA-95-037 1/2
2.15 0.82 1.92
Modular Sleeve GPA-95-292 — — — — —
(54.6) (20.8) (48.8)
Modular Sleeve 3.60 .82 3.43 2.98 0.78
GPA-95-969 — — —
With T-Bracket (91.4) (20.8) (87.1) (75.7) (19.8)
Modular Manifold 2.30 2.00 0.72 1.57 0.98
GPA-95-919 1/4 — —
Block (3 Auxiliary Ports) (58.4) (50.8) (18.3) (39.9) (24.9)
GPA-95-096 1/4
Modular 3-Way 2.38 2.51 0.69
GPA-95-097 3/8 — — — —
Shut-off Valve (60.4) (63.7) (17.5)
GPA-95-098 1/2
Modular Right 2.75 1.25 2.38 1.00 0.63 1.75 2.00
GPA-95-042 —
Angle Bracket (69.8) (31.7) (60.4) (25.4) (16.0) (44.5) (50.8)
GPA-95-223 1/4
GPA-95-224 3/8
Modular Connecting 1.25 1.19 0.75
GPA-95-225 1/2 — — — —
End Block Set (31.7) (30.2) (19.0)
GPA-95-320 3/4
GPA-95-321 1

D19 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Modular Accessories

Modular Accessories – 39 Series

Port Block Kits


39 Series

Port Block Kits allow units to be installed or removed as


modular components.
Each Kit includes all the necessary pieces to make two port
connections. Replacement Body Covers C-Bracket
P3NKA00PM

D Dimensions Inches (mm)

Accessories Part Number Pipe Size A B C D E F G


Replacement Each Kit contains two covers.
P3NKA00PM —
Body Covers All units are shipped with body covers.
Accessories & Repair Kits

P3NKB96CP 3/4 Inch NPT


P3NKB98CP 1 Inch NPT Individual Filters, Individual Regulators and 2-Piece Filter
P3NKB16CP 3/4 Inch BSPP* and Regulator Assemblies

P3NKB18CP 1 Inch BSPP*


P3NKB96CL 3/4 Inch NPT
Port Block Kits
P3NKB98CL 1 Inch NPT
2 and 3 Piece Combinations including a Lubricator (FR/L & FRL),
P3NKB16CL 3/4 Inch BSPP* Individual Lubricators, Individual Coalescing Filters and 2-Piece Filter and
Coalescer Assemblies
P3NKB18CL 1 Inch BSPP*
P3NKB9BCP 1-1/2" NPT
P3NKB1BCP 1-1/2" BSPP*
* 3/4", 1" & 1-1/2" meet ISO 1179-1 standard.

D20 Pneumatic Division


Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Safety Guidelines

Safety Guide For Selecting And Using Pneumatic Division


Products And Related Accessories
! WARNING:
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEMBLIES
OR RELATED ITEMS (“PRODUCTS”) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAMAGE.
POSSIBLE CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS
INCLUDE BUT ARE NOT LIMITED TO:
• Unintended or mistimed cycling or motion of machine members or failure to cycle
• Work pieces or component parts being thrown off at high speeds.
• Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device.
• Explosion
• Suddenly moving or falling objects.
• Release of toxic or otherwise injurious liquids or gasses.
Before selecting or using any of these Products, it is important that you read and follow the instructions below.

1. GENERAL INSTRUCTIONS
1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division Valves,
FRLs (Filters pressure Regulators and Lubricators), Vacuum products and related accessory components.
1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all
systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or
property.
1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see:
ISO 4414:1998, Pneumatic Fluid Power – General Rules Relating to Systems. See www.iso.org for ordering information.
1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or
Vacuum products. Do not select, or use Wilkerson valves, FRLs or vacuum products without thoroughly reading and understanding this
safety guide as well as the specific Wilkerson publications for the products considered or selected.
1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Wilkerson
and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system.
This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own
analysis and testing, is solely responsible for:
• Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory.
• Assuring that all user’s performance, endurance, maintenance, safety, and warning requirements are met and that the application
presents no health or safety hazards.
• Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the
valves, FRLs or Vacuum products are used; and,
• Assuring compliance with all applicable government and industry standards.
1.6. Safety Devices: Safety devices should not be removed, or defeated.
1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured.
1.8. Additional Questions: Call the appropriate Wilkerson technical service department if you have any questions or require any
additional information. See the Wilkerson publication for the product being considered or used, or call 269-629-2550, or go to
www.wilkersoncorp.com, for telephone numbers of the appropriate technical service department.
2. PRODUCT SELECTION INSTRUCTIONS
2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system.
System components need to be able to provide adequate flow and pressure for the desired application.
2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the instruction
sheets supplied for maximum pressure ratings.
2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product and
result in complete product failure.
2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic

H

Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual
circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to
premature failure of a product.
2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of
synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the
factory or product literature for materials of construction.
Safety Guidelines

2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures:
• Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures
outside of the rated range.
• Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols.
• Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as
phosphate ester and di-ester lubricants.

H2 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Safety Guidelines

2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins
Tec-3, Tec-4, and Tec-5
2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage.
• Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders.
• Do not exceed the maximum primary pressure rating of any pressure regulator or any system component.
• Consult product labeling or product literature for pressure rating limitations.
3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS
3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be performed.
All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any signs of
nonconformance.
3.2. Installation Instructions: Wilkerson published Installation Instructions must be followed for installation of Wilkerson valves, FRLs and
vacuum components. These instructions are provided with every Wilkerson valve or FRL sold, or by calling 269-629-2550, or at
www.wilkersoncorp.com.
3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient
temperature can drop below freezing
4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS
4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced
without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience
with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or
replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must
be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10.
4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate Service
Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation
Instructions are provided with every Wilkerson valve and FRL sold, or are available by calling 269-629-2550, or by accessing the Wilkerson
web site at www.wilkersoncorp.com.
4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more
information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout)
4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged
components:
• Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an
indication of worn or damaged components.
• Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation.
• Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior.
• Any observed improper system or component function: Immediately shut down the system and correct malfunction.
• Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations.
Caution: Leak detection solutions should be rinsed off after use.
4.5. Routine Maintenance Issues:
• Remove excessive dirt, grime and clutter from work areas.
• Make sure all required guards and shields are in place.
4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate
properly and safely.
4.7. Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum
products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly
accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need
to be established based on:
• Previous performance experiences.
• Government and / or industrial standards.
• When failures could result in unacceptable down time, equipment damage or personal injury risk.
4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal injury
and property damage:
• Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout Tagout
procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout).
• Disconnect electrical supply (when necessary) before installation, servicing, or conversion.
• Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service, or
conversion.
H
• Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how
pneumatic products are to be applied.
• After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested for
Safety Guidelines

proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into
use.
• Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local
representative for replacement labels.
4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions
supplied with the valve FRL or vacuum component to insure proper function of the system.

H3 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Safety Guidelines

Warning: Use Limitations Some of the Materials that will Attack


Wilkerson's warranties are void, and Wilkerson assumes no Polycarbonate Plastic Bowls
responsibility for any resulting cost, loss, injury or any other damages Acetaldehyde Chloroform Milk of Lime (CaOH)
whatsoever, with respect to any plastic bowl unit for which a bowl Acetic acid (conc.) Cresol Nitric Acid (conc.)
guard is standard equipment if the unit is placed in service without Acetone Cyclohexanol Nitrobenzene
the bowl guard and, except as otherwise specified in writing by Acrylonitrile Cyclohexanone Nitrocellulose Lacquer
Wilkerson, with respect to any Wilkerson products which are used in Ammonia Cyclohexene Phenol
other than compressed air service. Specific warnings with respect to Ammonium Fluoride Dimethyl Formamide Phosphorous Hydroxy
these and other use limitations appear elsewhere in this catalog. Ammonium Hydroxide Diozane Chloride
Ammonium Sulfide Ethgane tetrachloride Perchlorethylene
Wilkerson maintains a policy of ongoing product development
Anaerobic adhesives Ethyl Acetate Phosphorous
and improvement. We therefore reserve the right to change
Trichloride and Sealants Ethyl Ether Propionic Acid
dimensions specification and design without notice.
Antifreeze Ethylamine Pyridine
Do not place plastic bowl unit in service without bowl guard Benzene Ethylene Chlorohydrin Sodium Hydroxide
installed. Benzoic Acid Ethylene Dichloride Sodium Sulfide
Plastic bowl units are sold only with bowl guards with the exception Benzyl Alcohol Ethylene Glycol Styrene
to miniature units (C04, F00, L00, & M00). To minimize the danger Brake Fluids Formic Acid (conc.) Sufuric Acid (conc.)
of flying fragments in the event of plastic bowl failure, the bowl Bromobenzene Freon (Refrig. & Propell.) Sulphural Chloride
guards should not be removed. If the unit is in service without the Butyric Acid Gasoline (High Aromatic) Tetrahydronaphthalene
bowl guard installed, manufacturer's warranties are void, and the Carbolic Acid Hydrazine Tiophene
manufacturer assumes no responsibility for any resulting loss. Carbon Disulfide Hydrochloric Acid (conc.) Toluene
Carbon Tetrachloride Lacquer Thinner Turpentine
If the unit has been in service and does not have a bowl guard, Caustic Potash Solution Methyl Alcohol Xylene & Others
order one and install before placing back in service. Caustic Soda Solution Methylene Chloride
Chlorobenzene Methylene Salicylate
Caution
Certain compressor oils, chemicals, household cleaners, solvents, Trade Names of some Compressor Oils,
paints and fumes will attack plastic bowls and can cause bowl failure.
Do not use near these materials. When bowl becomes dirty replace Rubber Compounds and other Materials
bowl or wipe only with a clean, dry cloth. Reinstall bowl guard or buy that will Attack Polycarbonate Plastic
and install a bowl guard. Immediately replace any crazed, cracked,
damaged or deteriorated plastic bowl with a bowl or a new plastic Bowls.
bowl and bowl guard. Atlas "Perma-Guard" National Compound #N11
Buna N "Nylock" VC-3

Caution Cellulube #150 and #220


Crylex #5 cement
Parco #1306 Neoprene
*Permabond 910
Except as otherwise specified by the manufacturer, this product *Eastman 910 Petron PD287
is specifically designed for compressed air service, and use with Garlock #98403 (polyurethane) Prestone
any other fluid (liquid or gas) is a misapplication. For example, Haskel #568-023 Pydraul AC
use with or injection of certain hazardous liquids or gases in the Hilgard Co.'s hil phene Sears Regular Motor Oil
system (such as alcohol or liquid petroleum gas) could be harmful Houghton & Co. oil #1120, Sinclair oil "Lily White"
to the unit or result in a combustible condition or hazardous #1130 & #1055 Stauffer Chemical FYRQUEL #150
external leakage. Before using with fluids other than air, or for non- Houtosafe 1000 Stillman #SR 269-75 (polyurethane)
industrial applications, or for life support systems, consult Wilkerson Kano Kroil Stillman #SR 513-70 (neoprene)
Operations for written approval. Keystone penetrating oil #2 Tannergas
*Loctite 271 Telar
*Locite 290 Tenneco anderol #495 & #500 oils
*Loctite 601 Titon
*Loctite Teflon-Sealant *Vibra-tite
Marvel Mystery Oil Zerex
Minn. Rubber 366Y
*When in raw liquid form.
We cannot possibly list all harmful substances, so check with
Mobay or the General Electric office for further information on
polycarbonate plastic.
The trade names “EconOmist” and “Flow-Guide” are registered at

H the United States Patent Office.


“Auto-Fill”, “Dial-Air”, “Flex-Drain”, “Mainliner” and “Whirl-Flo” are
tradenames of Wilkerson.
Safety Guidelines

Claims and Shortages: Risk of loss passes to buyer when goods are delivered to the carrier. Inspect all shipments for damage at time of receipt.
Claims should be filed by the consignee against the carrier.

Changes: Wilkerson maintains a policy of ongoing product development and improvement.


We therefore reserve the right to change dimensions, specifications and design without notice.

H4 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com
Catalog 9EM-TK-190-3 Offer of Sale

Offer of Sale
The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized distributors
(“Seller”) are hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following
Terms and Conditions. Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All
goods or work described will be referred to as “Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out
Products, to or from Buyer is subject to these Terms and Conditions or any newer version of of: (a) improper selection, improper application or other misuse of Products purchased by
the terms and conditions found on-line at www.parker.com/saleterms/. Seller objects to any Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use
contrary or additional terms or conditions of Buyer’s order or any other document issued by of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product;
Buyer. or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify
2. Price Adjustments; Payments. Prices stated on Seller’s quote or other documentation Buyer under any circumstance except as otherwise provided.
offered by Seller are valid for 30 days, and do not include any sales, use, or other taxes 12. Cancellations and Changes. Orders shall not be subject to cancellation or change
unless specifically stated, Unless otherwise specified by Seller, all prices are F.C.A. Seller’s by Buyer for any reason, except with Seller’s written consent and upon terms that will
facility (INCOTERMS 2010). Payment is subject to credit approval and is due 30 days from indemnify, defend and hold Seller harmless against all direct, incidental and consequential
the date of invoice or such other term as required by Seller’s Credit Department, after loss or damage. Seller may change product features, specifications, designs and availability
which Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or the with notice to Buyer.
maximum allowable rate under applicable law. 13. Limitation on Assignment. Buyer may not assign its rights or obligations under this
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and agreement without the prior written consent of Seller.
Seller shall not be responsible for any damages resulting from any delay. Regardless of 14. Force Majeure. Seller does not assume the risk and shall not be liable for delay
the manner of shipment, title to any products and risk of loss or damage shall pass to or failure to perform any of Seller’s obligations by reason of circumstances beyond the
Buyer upon placement of the products with the shipment carrier at Seller’s facility. Unless reasonable control of Seller (hereinafter “Events of Force Majeure”) Events of Force Majeure
otherwise stated, Seller may exercise its judgment in choosing the carrier and means of shall include without limitation: accidents, strikes or labor disputes, acts of any government
delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated or government agency, acts of nature, delays or failures in delivery from carriers or suppliers,
will be made except on terms that will indemnify, defend and hold Seller harmless against all shortages of materials, or any other cause beyond Seller’s reasonable control.
loss and additional expense. Buyer shall be responsible for any additional shipping charges 15. Waiver and Severability. Failure to enforce any provision of this agreement will not
incurred by Seller due to Buyer’s acts or omissions. waive that provision nor will any such failure prejudice Seller’s right to enforce that provision
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in in the future. Invalidation of any provision of this agreement by legislation or other rule of law
material or workmanship for a period of twelve months from the date of delivery to Buyer or shall not invalidate any other provision herein. The remaining provisions of this agreement
2,000 hours of normal use, whichever occurs first. The prices charged for Seller’s products will remain in full force and effect.
are based upon the exclusive limited warranty stated above, and upon the following 16. Termination. Seller may terminate this agreement for any reason and at any time by
disclaimer: DISCLAIMER OF WARRANTY: THIS WARRANTY COMPRISES THE SOLE giving Buyer thirty (30) days written notice of termination. Seller may immediately terminate
AND ENTIRE WARRANTY PERTAINING TO PRODUCTS PROVIDED HEREUNDER. this agreement, in writing, if Buyer: (a) commits a breach of any provision of this agreement
SELLER DISCLAIMS ALL OTHER WARRANTIES, EXPRESS AND IMPLIED, (b) appointments a trustee, receiver or custodian for all or any part of Buyer’s property (c)
INCLUDING DESIGN, MERCHANTABILITY AND FITNESS FOR A PARTICULAR files a petition for relief in bankruptcy on its own behalf, or by a third party (d) makes an
PURPOSE. assignment for the benefit of creditors, or (e) the dissolves or liquidates all or a majority of its
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon assets.
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days 17. Governing Law. This agreement and the sale and delivery of all Products hereunder
of delivery. No other claims against Seller will be allowed unless asserted in writing within 30 shall be deemed to have taken place in and shall be governed and construed in accordance
days after delivery. Buyer shall notify Seller of any alleged breach of warranty within 30 days with the laws of the State of Ohio, as applicable to contracts executed and wholly performed
after the date the defect is or should have been discovered by Buyer. Any action based upon therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and
breach of this agreement or upon any other claim arising out of this sale (other than an action consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio
by Seller for an amount due on any invoice) must be commenced within 12 months from the with respect to any dispute, controversy or claim arising out of or relating to this agreement.
date of the breach without regard to the date breach is discovered.
18. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. or similar rights except as provided in this Section. Seller will defend and indemnify Buyer
IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense
RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF and will pay the cost of any settlement or damages awarded in an action brought against
USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR Buyer based on an allegation that a Product sold pursuant to this Agreement infringes the
EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, Intellectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer
EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of
OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY such allegations of infringement, and Seller having sole control over the defense of any
CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. allegations or actions including all negotiations for settlement or compromise. If a Product is
7. User Responsibility. The user, through its own analysis and testing, is solely subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may,
responsible for making the final selection of the system and Product and assuring that all at its sole expense and option, procure for Buyer the right to continue using the Product,
performance, endurance, maintenance, safety and warning requirements of the application replace or modify the Product so as to make it noninfringing, or offer to accept return of
are met. The user must analyze all aspects of the application and follow applicable industry the Product and return the purchase price less a reasonable allowance for depreciation.
standards and Product information. If Seller provides Product or system options, the user is Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based
responsible for determining that such data and specifications are suitable and sufficient for on information provided by Buyer, or directed to Products delivered hereunder for which
all applications and reasonably foreseeable uses of the Products or systems. the designs are specified in whole or part by Buyer, or infringements resulting from the
8. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, modification, combination or use in a system of any Product sold hereunder. The foregoing
confidential information or equipment furnished by Buyer or any other items which become provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole
Buyer’s property, may be considered obsolete and may be destroyed by Seller after two and exclusive remedy for infringement of Intellectual Property Rights.
consecutive years have elapsed without Buyer ordering the items manufactured using such 19. Entire Agreement. This agreement contains the entire agreement between the Buyer
property. Seller shall not be responsible for any loss or damage to such property while it is and Seller and constitutes the final, complete and exclusive expression of the terms of sale.
in Seller’s possession or control. All prior or contemporaneous written or oral agreements or negotiations with respect to the
Offer of Sale
9. Special Tooling. A tooling charge may be imposed for any special tooling, including subject matter are herein merged.
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. 20. Compliance with Law, U. K. Bribery Act and U.S. Foreign Corrupt Practices Act.
Such special tooling shall be and remain Seller’s property notwithstanding payment of any Buyer agrees to comply with all applicable laws and regulations, including both those of the
charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to United Kingdom and the United States of America, and of the country or countries of the
Seller which is utilized in the manufacture of the Products, even if such apparatus has been Territory in which the Buyer may operate, including without limitation the U. K. Bribery Act,
specially converted or adapted for such manufacture and notwithstanding any charges paid the U.S. Foreign Corrupt Practices Act (“FCPA”) and the U.S. Anti-Kickback Act (the “Anti-
by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise Kickback Act”), and agrees to indemnify and hold harmless Seller from the consequences
dispose of any special tooling or other property in its sole discretion at any time. of any violation of such provisions by Buyer, its employees or agents. Buyer acknowledges
10. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise, that they are familiar with the provisions of the U. K. Bribery Act, the FCPA and the Anti-
Seller shall retain a security interest in the goods delivered and this agreement shall be Kickback Act, and certifies that Buyer will adhere to the requirements thereof. In particular,
deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes Seller Buyer represents and agrees that Buyer shall not make any payment or give anything of
as its attorney to execute and file on Buyer’s behalf all documents Seller deems necessary value, directly or indirectly to any governmental official, any foreign political party or official
to perfect its security interest.
11. Improper use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless
thereof, any candidate for foreign political office, or any commercial entity or person, for the
purpose of influencing such person to purchase products or otherwise benefit the business
J
from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for of Seller.
personal injury, property damage, patent, trademark or copyright infringement or any other          02/12

J1 Pneumatic Division
Richland, Michigan
www.wilkersoncorp.com

Potrebbero piacerti anche