Sei sulla pagina 1di 9

FUGRO GEOTECH (INDIA) PVT. LTD.

  T ‐ 3569
Plot No. 51, Sector-6,Sanpada, Navi Mumbai-400 705 India.Phone: +912265168662/5674 Fax :+912227754011 Email : mail@fugroindia.com

LABORATORY TEST REPORT - ROCK SAMPLES

Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017

Customer Add. L&T - STEC MUMBAI Date Test Started 27/9/2016

FGTL Project No. 16-1474 Date Test Completed 30/1/2017

Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
IS 9143:1979
Standard Followed ISRM IS.13030.1991 IS 8764 IS 10082 IS:13047
(Reaffirmed 2011)

Quantity of Test Completed -- -- 9 7 6 7 7 7 1 4 18 2

3.50 5.00 Saturated 11.371 5.494 1.92 0.49 1.29 2.65 2.65 2.70 -- 59.3 Failure along vertical axis

8.00 8.60 Saturated 11.36 5.484 2.710 5.485 9.6 97.4 Failure along vertical axis

11.30 12.80 Saturated 11.276 5.470 1.10 1.30 3.53 2.71 2.71 2.74 -- 83.1 Failure along vertical axis

14.30 15.80 Saturated 11.540 5.466 -- 49.6 Failure along inclined plane

15.80 16.80 Saturated 2.76 5.47 11.9


TNBH-104
17.30 18.80 Saturated 11.350 5.465 1.12 0.36 0.99 2.74 2.74 2.77 -- 67.4 Failure along vertical axis

20.30 21.80 Saturated 11.380 5.473 -- 60.7 Failure along vertical axis

24.80 26.30 Saturated 10.960 5.481 3.141 5.487 4.3 29.0 Failure along vertical axis

Sample disintigrated while


26.30 27.80 Saturated 11.344 5.465 2.74 6.46 2.36 2.36 -- -- saturation

29.30 30.00 Saturated 11.564 5.471 -- 41.7 Failure along inclined plane

8.50 9.70 Saturated 5.294 5.435 1.44 0.74 2.72 2.72 2.76 3.0 --

9.70 11.00 Saturated 7.09 5.433 -- 28.9 Failure along the Vertical axis

9.70 11.00 Saturated 2.84 5.43 -- 2.4 --

11.00 12.50 Saturated 7.946 5.446 -- 25.5 Failure along the Vertical axis

12.50 14.00 Saturated 11.115 5.437 -- 44.8

12.50 14.00 Saturated 2.99 5.43 5.08 -- -- -- -- -- 2.4 --

14.00 15.50 Saturated 8.441 5.441 -- 12.3 Joint Failure


TNBH-109
15.50 17.00 Saturated 11.231 5.442 2.51 2.76 7.00 2.53 2.53 2.60 -- 18.3 Joint Failure

17.00 18.50 Saturated 8.24 5.484 -- -- 52.9 Failure along the Vertical axis

18.50 20.00 Saturated 11.003 5.478 -- 55.0 Failure along inclined plain

20.00 21.50 Saturated 10.987 5.489 1.22 0.52 1.34 2.56 2.56 2.59 -- 59.4 Failure along the Vertical axis

23.00 24.50 Saturated 11.005 5.488 -- 53.6 Failure along the Vertical axis

26.00 27.50 Saturated 10.905 5.488 0.88 0.52 1.38 2.66 2.66 2.68 -- 53.3 Failure along the Vertical axis

29.00 30.00 Saturated 11.256 5.491 -- 54.2 Failure along the Vertical axis
FUGRO GEOTECH (INDIA) PVT. LTD.
  T ‐ 3569
Plot No. 51, Sector-6,Sanpada, Navi Mumbai-400 705 India.Phone: +912265168662/5674 Fax :+912227754011 Email : mail@fugroindia.com

LABORATORY TEST REPORT - ROCK SAMPLES

Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017

Customer Add. L&T - STEC MUMBAI Date Test Started 27/9/2016

FGTL Project No. 16-1474 Date Test Completed 30/1/2017

Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
13.00 14.50 Saturated 11.037 5.460 4.93 3.78 8.92 2.36 2.36 2.48 -- 23.5 Failure along the Vertical axis

13.00 14.50 Saturated 2.97 5.48 -- 14.4 --

14.50 16.00 Saturated 10.847 5.462 -- 65.4 Failure along the Vertical axis

17.50 19.00 Saturated 10.967 5.461 -- 60.1 Failure along the Vertical axis

17.50 19.00 Saturated 2.55 5.47 3.18 -- -- -- -- -- 8.5


TNBH-110
19.00 20.50 Saturated -- 13 41

20.50 22.00 Saturated 10.821 5.460 0.99 0.86 2.29 2.68 2.68 2.70 -- 82.1 Failure along the Vertical axis

22.00 23.50 Saturated 11.138 5.456 -- 77.6 Failure along the Vertical axis

25.00 26.50 Saturated 10.94 5.458 1.12 0.60 1.60 2.66 2.66 2.69 -- 73.6 Failure along the Vertical axis

28.00 29.50 Saturated 11.217 5.448 -- 81.7 Failure along the Vertical axis

Pl value was below measurable unit


8.50 9.00 Saturated 4.791 -- -- -- -- -- of machine
Pl value was below measurable unit
14.00 15.50 Saturated 5.450 -- -- -- -- -- of machine

15.50 17.00 Saturated 5.477 2.92 5.47 -- -- -- -- 0.35 3.9 --

17.00 18.50 Saturated 5.465 -- -- -- -- 0.18 --

TNBH-111 18.50 20.00 Saturated 10.912 5.484 41.3

21.50 23.00 Saturated 11.165 5.482 1.72 1.33 3.44 2.59 2.59 2.63 64.9

24.50 26.00 Saturated 10.932 5.480 88.2

27.50 29.00 Saturated 10.944 5.485 0.63 0.85 2.29 2.70 2.70 2.71 61.9

23.00 24.50 Saturated 2.76 5.48 6.1 --


FUGRO GEOTECH (INDIA) PVT. LTD.
  T ‐ 3569
Plot No. 51, Sector-6,Sanpada, Navi Mumbai-400 705 India.Phone: +912265168662/5674 Fax :+912227754011 Email : mail@fugroindia.com

LABORATORY TEST REPORT - ROCK SAMPLES

Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017

Customer Add. L&T - STEC MUMBAI Date Test Started 27/9/2016

FGTL Project No. 16-1474 Date Test Completed 30/1/2017

Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
7.00 8.00 Saturated 10.861 5.454 1.13 0.98 2.68 2.73 2.73 2.76 42.8

9.00 10.50 Saturated 10.885 5.488 2.607 5.484 8.9 78.1

10.50 12.00 Saturated 11.087 5.470 42.6

12.00 13.50 Saturated 10.870 5.473 0.55 0.12 0.34 2.76 2.76 2.78 53.1

15.00 16.50 Saturated 10.922 5.464 46.9


TNBH-112
18.00 19.50 Saturated 10.850 5.447 0.61 0.08 0.21 2.78 2.78 2.79 60.0

19.50 21.00 Saturated 2.652 5.457 6.6 --

24.00 25.50 Saturated 10.820 5.448 0.82 0.08 0.23 2.77 2.77 2.79 17.1

27.00 28.50 Saturated 11.140 5.454 36.4

31.00 32.50 Saturated 11.093 5.425 0.89 0.44 1.21 2.72 2.72 2.75 36.8

Abbreviations used m - Meter, cm - Centimeter, Mpa - Mega pascal, C - Cohesion, Ø - Angle of internal friction

Notes : The results listed refer only to the tested sample(s) and Parameter(s).
Endorsement of products is neither inferred nor implied.
This report is not to be reproduced wholly or in part and cannot be used as evidence in the Court of law and should not be used in any advertising media without our special permission in writing
The samples will be destroyed after 15 days from the date of issue of test certificate unless otherwise specified.
Test with * mark are not under NABL accreditation scope
----END OF REPORT----

Format No. FM-LTR-2 ; Issued on 01/11/2007; Revised on 28/06/2015; Revision No.02