Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
T ‐ 3569
Plot No. 51, Sector-6,Sanpada, Navi Mumbai-400 705 India.Phone: +912265168662/5674 Fax :+912227754011 Email : mail@fugroindia.com
Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017
Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
IS 9143:1979
Standard Followed ISRM IS.13030.1991 IS 8764 IS 10082 IS:13047
(Reaffirmed 2011)
3.50 5.00 Saturated 11.371 5.494 1.92 0.49 1.29 2.65 2.65 2.70 -- 59.3 Failure along vertical axis
8.00 8.60 Saturated 11.36 5.484 2.710 5.485 9.6 97.4 Failure along vertical axis
11.30 12.80 Saturated 11.276 5.470 1.10 1.30 3.53 2.71 2.71 2.74 -- 83.1 Failure along vertical axis
14.30 15.80 Saturated 11.540 5.466 -- 49.6 Failure along inclined plane
20.30 21.80 Saturated 11.380 5.473 -- 60.7 Failure along vertical axis
24.80 26.30 Saturated 10.960 5.481 3.141 5.487 4.3 29.0 Failure along vertical axis
29.30 30.00 Saturated 11.564 5.471 -- 41.7 Failure along inclined plane
8.50 9.70 Saturated 5.294 5.435 1.44 0.74 2.72 2.72 2.76 3.0 --
9.70 11.00 Saturated 7.09 5.433 -- 28.9 Failure along the Vertical axis
11.00 12.50 Saturated 7.946 5.446 -- 25.5 Failure along the Vertical axis
17.00 18.50 Saturated 8.24 5.484 -- -- 52.9 Failure along the Vertical axis
18.50 20.00 Saturated 11.003 5.478 -- 55.0 Failure along inclined plain
20.00 21.50 Saturated 10.987 5.489 1.22 0.52 1.34 2.56 2.56 2.59 -- 59.4 Failure along the Vertical axis
23.00 24.50 Saturated 11.005 5.488 -- 53.6 Failure along the Vertical axis
26.00 27.50 Saturated 10.905 5.488 0.88 0.52 1.38 2.66 2.66 2.68 -- 53.3 Failure along the Vertical axis
29.00 30.00 Saturated 11.256 5.491 -- 54.2 Failure along the Vertical axis
FUGRO GEOTECH (INDIA) PVT. LTD.
T ‐ 3569
Plot No. 51, Sector-6,Sanpada, Navi Mumbai-400 705 India.Phone: +912265168662/5674 Fax :+912227754011 Email : mail@fugroindia.com
Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017
Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
13.00 14.50 Saturated 11.037 5.460 4.93 3.78 8.92 2.36 2.36 2.48 -- 23.5 Failure along the Vertical axis
14.50 16.00 Saturated 10.847 5.462 -- 65.4 Failure along the Vertical axis
17.50 19.00 Saturated 10.967 5.461 -- 60.1 Failure along the Vertical axis
20.50 22.00 Saturated 10.821 5.460 0.99 0.86 2.29 2.68 2.68 2.70 -- 82.1 Failure along the Vertical axis
22.00 23.50 Saturated 11.138 5.456 -- 77.6 Failure along the Vertical axis
25.00 26.50 Saturated 10.94 5.458 1.12 0.60 1.60 2.66 2.66 2.69 -- 73.6 Failure along the Vertical axis
28.00 29.50 Saturated 11.217 5.448 -- 81.7 Failure along the Vertical axis
21.50 23.00 Saturated 11.165 5.482 1.72 1.33 3.44 2.59 2.59 2.63 64.9
27.50 29.00 Saturated 10.944 5.485 0.63 0.85 2.29 2.70 2.70 2.71 61.9
Report No GT/1474/16/R0/104
Project L&T - STEC MUMBAI JV Mumbai Metro Line 3 UGC 01
Report Date 30/1/2017
Sample
Tensile Strength *Point Load Index *Tensile *Rock Triaxial (Saturated)
Depth(m) Water *Dry *Saturated
Condition during *SMC Porosity *Dry Corrected Uniaxial Compressive
Borehole No. / Customer Ref. Length (cm) Diameter (cm) Absorption Density Density Strength (Is)50 Strength
Strength test (%) (%) Density Strength (Saturated ) MPa
Length Diameter (%) (g/cc) (g/cc) (MPa) (MPa)
From To
(cm) (cm) c, MPa Ø, Deg
Remarks
7.00 8.00 Saturated 10.861 5.454 1.13 0.98 2.68 2.73 2.73 2.76 42.8
12.00 13.50 Saturated 10.870 5.473 0.55 0.12 0.34 2.76 2.76 2.78 53.1
24.00 25.50 Saturated 10.820 5.448 0.82 0.08 0.23 2.77 2.77 2.79 17.1
31.00 32.50 Saturated 11.093 5.425 0.89 0.44 1.21 2.72 2.72 2.75 36.8
Abbreviations used m - Meter, cm - Centimeter, Mpa - Mega pascal, C - Cohesion, Ø - Angle of internal friction
Notes : The results listed refer only to the tested sample(s) and Parameter(s).
Endorsement of products is neither inferred nor implied.
This report is not to be reproduced wholly or in part and cannot be used as evidence in the Court of law and should not be used in any advertising media without our special permission in writing
The samples will be destroyed after 15 days from the date of issue of test certificate unless otherwise specified.
Test with * mark are not under NABL accreditation scope
----END OF REPORT----