CALCULATION
(Wastewater Treatment Facility)
Sierra Leone
Wasteswater Treatment Facility
Caculation Sheet for Drawing
2014. 08
Raw water Screen Effulent Bioreactor Influent Bioreactor Effulent Treated Water
Bioreactor Efficiency A/C Efficiency
Q = 330.0 Q = 330.0 Q = 331.4 Q = 328.72 Q = 328.72
BOD = 66.0 (200.0) BOD = 66.0 (200.0) BOD = 67.0 (202.2) BOD = 97.5% BOD = 1.6 (5.0) BOD = 60.0% BOD = 0.7 (2.0)
COD = 54.5 (165.0) COD = 54.5 (165.0) COD = 55.3 (166.8) COD = 88.0% COD = 6.6 (20.0) COD = 60.0% COD = 2.6 (8.0)
SS = 66.0 (200.0) SS = 56.1 (170.0) SS = 57.5 (173.4) SS = 97.1% SS = 1.6 (5.0) SS = 60.0% SS = 0.7 (2.0)
T-N = 13.2 (40.0) T-N = 13.2 (40.0) T-N = 13.3 (40.1) T-N = 55.1% T-N = 5.9 (18.0) T-N = 44.4% T-N = 3.3 (10.0)
T-P = 2.0 (6.00) T-P = 2.0 (6.00) T-P = 2.1 (6.19) T-P = 70.9% T-P = 0.59 (1.8) T-P = 44.4% T-P = 0.33 (1.0)
coliform 100,000 coliform 100,000 coliform 100,000 coliform 99.7% coliform 300 coliform 100.0% coliform 0
Aeration +
Sewage Influent SCREEN Equalization Tank Anoxic Anaerobic Exhausting A/C FILTER Outflow
Membrane
Inner Recycling
Screen Efficiency
Supernatant
BOD = 0.0% Q = 1.42
COD = 0.0% BOD = 1.01 (714.3)
SS = 15.0% COD = 0.84 (589.3)
T-N = 0.0% SS = 1.35 (952.4) WAS
T-P = 0.0% T-N = 0.09 (66.7) Q = 2.70
대장균수 0.0% T-P = 0.07 (51.5) BOD = 20.3 (7,500)
COD = 16.7 (6,188)
SS = 27.0 (10,000)
Sludge Thickening Tank
T-N = 1.9 (700)
T-P = 1.46 (540)
1. Background of Design
Inflow
Supernatant
Flow Control Tank
DRUM SCREEN
Inner Recycling
Anoxic Tank
Anaerobic Tank
Aeration Tank
A/C FILTER
Outflow
Process Calculation
2. Unit Processes
Function
■ Removal of relatively heavy substances such as grit, clay, rubber, metal and plastic
330 ㎥/day 1
V= ( × ) × 2.5 = 0.573 ㎥
24 60
Function
■ Screen and remove relatively bigger substances to protect following machines and pipes
*Tank Size : 0.7 W × 2.5 L × 0.8 H( 0.4 ) = 0.70 ㎥ (2 sets-1 set as stand by)
* Retention Time : 3.1 min
*ACCESSORY
M-101
Coarse Screen 30 mm - STS304 - 2 SET
A(B)
Function
■ Adjust and equalize the flow and BOD load of raw water. To prevent decay of sediment,
they usually use stirrer.
Q
*Capacity : V = ( ) × 10
24
330 ㎥/day
V=( ) × 10 = 137.5 ㎥
24
M-201
Raw Water Pump 80A x 0.3㎥/min x 12mH 2.2㎾ 2 SET Sub.
A(B)
Drum
M-202 Fine Screen #30×500Φ - STS304 0.75㎾ 1 SET
Screen
Function
■ Bioreactor consists of anoxic tank, anaerobic tank, aerobic tank(separation tank) and
O2 exhausting tank. Micro filter is installed in aerobic tank. Because micro filter has very
small pore size(0.4㎛), high conc. of microorganism can be retained in aerobic tank.
It makes it possible to accomplish the high treatment efficiency.
Standard of Design
■ Temp. ## ℃
■ DO 2.0 ㎎/ℓ
■ Target SRTaerobic 60 days(30~70)
■ Volatile Solids of Influent TSS 70% (70~80%)
■ Volatile Fraction of Solids(MLSS) 75% (70~80=75%), non-volatile solids = 20.5~23.6%
■ Nitrogen Content in Waste Sludge ##
(7~12% of WAS, 11~12% of Heterotrophic Biomass Produced)
Q Aerobic(membrane
Anoxic Anaerobic Exhauster
)
Zone Zone Zone
Zone
Q
* Internal recycle rate can be calculated by influent and effluent concentration of ammonia
and effluent concentration of nitrate.
■ The capacity of anaerobic tank is determined by the retention time of anaerobic tank.
The HRT of anaerobic tank is over 1.0 hr.
Retention Time(hr) over 1 hr이상
Flow Rate(㎥/day) 330 ㎥
over= 13.8 ㎥
Capacity of anaerobic tank = Flow rate(㎥/day) ÷ 24hr/day x HRT(hr)
* Tank Size
- 1st aeration zone :3.0 W × ## L × 3.3 H( 2.8 ) = 44.9 ㎥
- Separation zone :6.2 W × ## L × 3.3 H( 2.8 ) = 92.9 ㎥
* Total Capacity : 137.8 ㎥
* Retention Time :10.0 hr
Process Calculation
BOD × Q = 202.2 kg/day × 1000 = 0.147
*F/M Ratio =
V × MLSS 196.6 ㎥ × 7,000 mg/ℓ
110.47 kg·O2/day
= 398.82 ㎥·Air/day
0.277 kg·O2/㎥·Air
Because oxygen usage rate is 3% and effective depth of aeration zone is 2.8m,
398.82 ㎥·Air/day
= 13293.88 ㎥·Air/day = 9.23 ㎥·Air/day
0.03
Process Calculation
* The amout of air for the operation of membrane
1.0 ㎥/set·min × 10 SET = 10 ㎥/min
* Because the amount of air for biological respiration is more than that for the operation
of membrane, the amount for repiration is adapted and applied to design.
4) Exhausting Tank
(Q + QIMLR) x D.O
* Capacity(V) =
E.D
-.D.O(DO in mixed water) : 2.0mg/ℓ
-.IMLR : 1.5Q(150%)
-.E.D(Endogenous Demand) : 20mg/ℓ·hr
Function
■ Store and supply filtrate to the A/C filter tank to adsorb and remove metal, odor and color
from filtrate.
*ACCESSORY
M-801
Filtration Pump 80A×0.3㎥/min×20mH 2.2㎾ 2 SET Sub. High-Head
A(B)
Measuring Tank
M-803 500W×1,000L×500H - 1 SET STS304
(V-NOTCH)
Function
■ To clean the fouled activated carbons, supply and backwash the treated water periodically.
M-901
Backwashing Pump 80A x 0.3㎥/min x 23mH 3.7㎾ 2 SET Sub. High-Head
A(B)
Function
■ Store the treated water temporarily.
M-901
Backwashing Pump 80A x 0.3m3/min x 23mH 3.7㎾ 2 SET
A(B)
Disk
M-903 Diffuser Φ300×120L/min - 3 EA
type
Process Calculation
Function
■ Thicken the concentration of excessive sludge to minimize the volume of excessive sludge.
Y 0.6
Yobs = = = 0.15
1 + b·SRTaerobic 1 + 0.05 × 60
Generated amount of sludge from BOD removal : 0.2 × ( 67 - 1.64 ) = 9.81 kg/day
Amount of SS in influent = 57.5 kg/day
100
0.95 × 27.04 kg/day × ÷ 1000 kg/㎥ = 1.28 ㎥/day
100 - 98
Total amount of air = Aeration Zone + Separation Zone + Filtrate Tank + Backwashing
Water Tank + Treated Water Tank + Sludge Thickening Tank
= 0.72 + 10.48 + 0.3 + 0.2 + 0.3 + 0.8
= 12.8 × 1.2 (safety factor)
= 15.4 ㎥/min