TELAWNE POWER EQUIPMENTS PRIVATE LIMITED


R-457, MIDC, Rabale, Behind Pipeline Road,
Thane Belapur Road, Navi Mumbai - 400701. INDIA.
 +91-22-2764 2273 / 74 / 75  www.telawne.com
 +91-22-2764 2277  tpepl@telawne.com
Empowering Generations
OVERVIEW

Telawne Power Equipment is located in standards. Telawne has a capacity to


Asia’s Largest Manufacturing Zone of Navi produce over 750 MVA Transformers per EXHIBITIONS
Mumbai. The plant is spread over 38000 sq annum in assorted sizes and types.
ft. Our founder, Late Shri. Sudhakar 2006 2014
We are equipped with all infrastructure
Telawne having experience of over 17 years
facilities complete with Epoxy Flooring, Consistantly Participating Participated in Exhibition
in Crompton Greaves, Mumbai and started
Testing Pit (for better safety), Vacuum in ELECRAMA. on power in Sri Lanka, Ghana.
producing and servicing oil Immersed
Oven, Yokogawa Power Analyzer and also 2010 2015
distribution transformers, established by
the best Human Safety Equipments.
name of “Telawne Cromptek” in 1988. Participated in the Mactech 2010 CICC, Participated in Exhibition in Dubai,
Our success and growth has been mainly Egypt Exhibition also CEEAMA 2010. Russia, Myanmar.
All plants are certified by ISO 9001:2008 and
due to thrust and emphasis on quality
ISO 14001:2004. It has all the necessary
which never compromise to manufacture
Machinery for handling and producing
zero defect transformers.
transformers in accordance with IEC:60076
CERTIFICATIONS

CPRI Successfully Type Tested 1250 KVA - 22 kV;


5,10 and 20 MVA 33/11 kV Transformers at CPRI, Bangalore.
MILESTONES
ERDA Successfully Type Tested 100 to 2500 KVA - 11 & 22 kV,
Oil & Dry Type Transformer, Packaged & Pad Mounted Substations.
Established Indigenous Manufacturing facility at a 2003-2004
new location as “Telawne Power Equipments Pvt Ltd.
ASTA Complete Type Tested 1000KVA - 11/0.433 kV Oil Cooled
Distribution Transformer as per Gulf & African Utility Specification.
Expanded infrastructure and testing facility 2007-2008
for handling up to 50 MVA 132 kV.

Enhanced additional winding machinery for Foil 2010-2011 MOTTO


VPI type Dry Transformer Processing facility.

Installed foil winding machinery. Built separate section for 2015-2016


processing Dry type Transformer. Incorporated new casting
plant & partial Discharge (PD) Testing Arrangement
VALUES VISION MISSION
Maintain Transparency, To be market leader in To empower as world
Commitments & Harmonious Energy Efficient Transformers recognized service provider
relationship with Employees, & Unitised Substations and for Low Loss Transformers
OUR CREDENTIALS LAUNCH Business Associates & Well maintain. Consistent growth of & Compact Substations with
Wishers. Develop healthy & safe more than 50% annually. a zeal to create excellent
2012 Udyog Bodh 2014 SME 2015 SKOTCH 2014 2016 working environment & provide customer relationshipby being
for Business for SME Excellence for Business New Launch for Pad Mounted New Launch for Integrity throughout the transparent, commited
Excellence Award 2014 Excellence and Tower Substation Contenarized Substation Organisation. & maintaining Harmonious
relationship.

1 2
OIL IMMERSED
DISTRIBUTION TRANSFORMER

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Duty, Type Outdoor / Indoor, Pole or Ground Mounted We at TELAWNE manufacture both hermetically sealed, corrugated radiator type
• H. V. Bushing
and conventional GENERAL
rectangularDETAILS
tank type distribution Transformers. These
• L. V. Bushing Voltage Class 3.3, 6.6, 11, 22, 33 kV or any specific Transformers are generally used in distribution network for feeding residential,
No of Phases 1 or 3 Phase commercial & bulk consumers. Following are the dimensional, weight & quantity
• Off Circuit Tap Changer
details along with standard losses for conventional 11 KV distribution transformer
• Conservator oil filling hole Frequency 50/60 Hz (Off Circuit Type).
with cap & drain plug
Vector Group Dyn1 or Dyn5 or Dyn11 or any specific
• Under carriage with four SR. RATING OVERALL DIMENSIONS (MM) STANDARD LOSSES (W) OIL QTY. TOTAL WT.
Insulating Fluid PCB FREE Mineral Oil, both inhibited &
bi-directional rollers NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) NO LOAD FULL LOAD (LTRS) (KGS)
uninhibited, as per IS/IEC, ASTM D3487 and
• Earthing terminals customer requirement 1 100 1200 1400 1500 300 1750 235 750
Class A 2 150 1250 1500 1600 400 2500 350 1025
• Drain cum bottom filter Class of Insulation
valve with sampling plug 3 200 1300 1500 1700 480 3000 400 1225
Tap Changer Off Circuit or On Load
4 250 1400 1600 1750 540 3500 465 1365
• Top filter valve with ±2.5% X 2 for OCTC or + 1.25% X 4 & - 1.25%
Tapping Range 5 315 1500 1700 1800 580 4200 490 1500
sampling plug X 8 for OLTC or as per customer requirement
6 400 1600 1800 1850 720 5000 520 1800
• Plain Oil Level gauge Aluminium or Copper with multi paper
Winding Material 7 500 1700 2000 1900 850 5800 575 2200
covering
• Rating diagram plate 8 630 1800 2100 2000 1000 7000 650 2400
Applicable Standards IS 2026, IEC 60076, ANSI, IEEE 9 750 1900 2150 2200 1150 8000 750 2600
• Air release device
Painting Enamel, Epoxy, Polyurethane or customer R OPTIONAL FITTINGS 10 1000 2200 2200 2350 1500 10500 1000 4000
• Thermometer Pocket specific 11 1250 2300 2600 2400 1800 12500 1250 4750
• Detachable Radiators with
• Lifting lugs 12 1600 2400 3000 2600 2100 14250 1310 5450
isolating valves.
• Pressed Steel Radiators 13 2000 2600 3200 2400 2500 17000 1450 6000
• Jacking Pads
(Fins or corrugated type) 14 2500 2800 3300 2800 3000 20000 1650 7200
• Dial type Oil Temperature Indicator
• Double Diaphragm 15 3000 3200 3400 3000 3750 25000 1900 8250
with A/T contacts
Explosion Vent 16 5000 4500 4200 3200 6500 38000 3350 12950
• Dial type Winding Temperature
• Silica gel breather Indicator with A/T contacts *Dimensions and weight & losses may vary for any specific or special requirement.

• Additional Neutral bushing • Magnetic Oil Gauge with


A/T contacts R ASSURED FEATURES
• First filling of oil
• Buchholz relay with A/T contacts • Highest dielectric insulation property to withstand Lightening Impulse.
• Marshalling box with control wiring • Mechanical design to withstand short circuit forces arising during faults.
• Equaliser pipe between • Optimum oven heating under vacuum as to achieve desired compression height
conservator & explosion vent
and maximum insulation resistance (IR) to windings.
• On Load Tap Changer
• Adequate ducts between layers, coils, discs for maximum oil flow and reduced
• RTCC Panel with automatic hot spot temperature.
voltage Regulator (AVR)
• Step-lap designed CRGO laminations for lower losses and excitation current.
• Pressure Release valve
• Pre compressed Insulation material for minimal moisture absorption.
• DGPT Relay

3 4
POWER
TRANSFORMER

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Duty, Type Outdoor / Indoor We manufacture both on load & off circuit tap switch type power transformer.
• H. V. Bushing / L. V. Bushing
These TransformersGENERAL DETAILS
are generally used in receiving substation for feeding residen-
• Conservator oil filling hole Voltage Class 11, 22, 33, 66 kV or any specific tial, commercial & bulk consumers. Following are the dimension, oil quantity &
No of Phases 3 Phase weight details along with standard & low losses for 33KV Power transformer with
• Bi-directional rollers
On Load Tap Changer.
• Earthing terminals pads Frequency 50/60 Hz
STANDARD TRANSFORMER WITH OLTC
• Drain cum bottom filter valve Vector Group Dyn5 or Dyn11 or YNyn0 any specific
SR. RATING OVERALL DIMENSIONS (MM) LOSSES (W) OIL QTY. TOTAL WT.

• Top filter valve with sampling Insulating Fluid PCB FREE Mineral Oil, both inhibited & NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) NO LOAD LOAD % (LTRS) (KGS)
plug uninhibited, as per IS/IEC, ASTM D3487
1 3150 3300 3000 3500 4000 24000 7.15 2450 9250
• Plain Oil Level gauge Class of Insulation Class A 2 5000 3500 3200 3600 5500 33000 7.15 3300 11550

Tap Changer Off circuit or on load tap changer 3 6300 3600 3000 3800 6500 40000 7.15 3800 13250
• Rating diagram plate
4 8000 3800 3100 3900 8000 48000 8.35 4200 15000
• Air release device Tapping Range ±2.5% X 2 for OCTC or + 1.25% X 4 & - 1.25%
X 8 for OLTC or as per customer requirement 5 10000 4000 3600 4000 9000 57000 8.35 4800 17500
• Thermometer Pocket 6 12500 4200 3800 4200 10000 67000 8.35 5200 19500
Winding Material Copper with multi paper covering
• Lifting lugs 7 16000 4400 4000 4400 12000 80000 10.00 6300 22250
Applicable Standards IS 2026, IEC 60076, ANSI, IEEE
LOW LOSS TRANSFORMER WITH OLTC
• Pressed steel Radiators
Painting Enamel, Epoxy, Polyurethane or customer 1 3150 3500 3000 3300 3000 14000 7.15 2700 10850
(Detachable)
specific
• Double Diaphragm Explosion R OPTIONAL FITTINGS 2 5000 3700 3200 3400 3900 19000 7.15 3600 14150

Vent 3 6300 3800 3000 3600 4500 25000 7.15 4200 15000
• Dial type WTI with A/Tcontact
4 8000 4000 3100 3700 5000 32000 8.35 4600 17850
• Silica gel breather • Magnetic Oil Gauge with A/T
5 10000 4200 3600 3800 5400 37000 8.35 5200 21500
• Additional Neutral bushing contacts
6 12500 4400 3800 4000 6000 43000 8.35 5700 24500
• On Load Tap Changer
• First filling of oil 7 16000 4600 4000 4200 7000 52000 10.00 6800 28250
• RTCC Panel with automatic
• Isolating valves for radiator *Dimensions and weight & Losses may vary for any specific or special requirement.
voltage Regulator (AVR)
• Jacking Pads • Pressure Release valve
R ASSURED FEATURES
• Dial type OTI with A/T contacts • DGPT Relay
• Highest dielectric insulation property to withstand lightening impulse.
• Buchholz relay with A/T • Air cell bag
• Mechanical design to withstand short circuit forces arising during faults.
contacts • Scada Compatible OTI & WTI • Optimum oven heating under vacuum as to achieve desired compression height
• Marshalling box with • Equaliser pipe between conservato and maximum insulation resistance (IR) to windings.
control wiring & explosion vent • Adequate ducts between layers, coils, discs for maximum oil flow and reduced
• Annunciators in RTCC panel hot spot temperature.
• Step-lap designed CRGO laminations for lower losses and excitation current.
• Force cooling arrangement with
fan cubical • Pre compressed Insulation material for minimal moisture absorption.
• Permawood rings for uniform clamping.

5 6
EXTRA HIGH VOLTAGE
TRANSFORMER

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Duty, Type Outdoor / Indoor We manufacture both on load & off circuit tap switch type EHV transformer. EHV
• H.V Bushing / L.V Bushing
GENERAL
transformer have voltage classDETAILS
66KV or above. These transformer are generally
• Conservator with oil filling hole Voltage Class 66, 100, 110, 132, 220 kV or any specific used for stepping down voltage from transmission line. EHV transformer generally
• Rollers (Plain / Flange) have force cooling & on load tap changer. Following are the dimension, oil quantity
No of Phases 3 Phase
• Earthing terminal pads & weight details along with standard & low losses for 66kV & 132kV EHV power
Frequency 50/60 Hz transformer with On Load Tap Changer having ONAN /ONAF Cooling.
• Drain with bottom filter valve
• Top filter valve with sampling Vector Group Dyn5 or Dyn11 or YNyn0 any specific
STANDARD TRANSFORMER WITH OLTC
plug
Insulating Fluid PCB FREE Mineral Oil, both inhibited & SR. RATING OVERALL DIMENSIONS (MM) LOSSES (W) OIL QTY. TOTAL WT..
• Shut off valve uninhibited, as per IS / IEC, ASTM D3487
NO. (MVA) LENGTH (L) BREADTH (B) HEIGHT (H) NO LOAD LOAD % (LTRS) (KGS)
• Plain oil level gauge Class A
Class of Insulation 1 10/12.5 5100 3900 4100 9 60 10 8300 24000
• Rating diagram plate
Tap Changer Off Circuit or On load tap Changer 2 12.5/16 5800 4500 4400 11.5 70 10 8400 28000
• Terminal Marking Plate
±2.5% x 2 for OCTC or +1.25% x 4 & -1.25% x 3 16/20 7000 4900 4750 13 85 10 13000 34000
• Air release device Tapping Range
8 for OLTC or as per customer requirement 4 20/25 7500 5000 5200 16 100 10 14000 42000
• Thermometer Pocket
Winding Material Copper with multi paper covering 5 25/31.5 8000 5100 5750 20 120 10 20000 52000
• Lifting lugs
6 32/40 8400 5650 6000 25 150 12.5 21000 63000
• Pressed Steel Radiators Applicable Standards IS 2026, IEC 60076, ANSI, IEEE
7 40/50 8600 5750 6150 31.5 185 12.5 22000 70000
(Detachable)
Painting Epoxy, Polyurethane or customer specific LOW LOSS TRANSFORMER WITH OLTC
• Double Diagram Explosion Vent
1 10/12.5 5300 4100 4300 7 40 10 9130 26400
• Equaliser pipe between
• Silica Gel Breather
R OPTIONAL FITTINGS 2 12.5/16 6000 4700 4600 9.5 48 10 9240 30800
• Pressure Release Valve 3 16/20 7200 5100 4950 11.5 60 10 14000 36550
• Additional Neutral Bushing
• Air cell bag 4 20/25 8000 5200 5400 14 76 10 15050 45150
• First filling of oil
5 25/31.5 8300 5400 5950 18 92 10 21000 54600
• Isolating valves for radiator • Scada Compatible OTI & WTI
6 32/40 8700 5950 6200 21 120 12.5 22050 66150
• Jacking Pads • Annunciator in RTCC panel
7 40/50 8900 6050 6450 25 150 12.5 23100 73500
• Dial type OTI with A/T contacts • Force cooling arrangement with
*Dimensions and weight & Losses may vary for any specific or special requirement.
• Dial type WTI with A/T contacts fan cubical
• Marshalling Box with control • Anti vibration pads
wiring R ASSURED FEATURES
• Fire fighting process
• Buchholz relay with A/T • Highest Dielectric insulation property to withstand Lightning impulse.
contacts • RTD for oil & winding
• Step lap designed CRGO laminations for lower losses & excitation current.
• Magnetic Oil Gauge with A/T • Nitrogen purging system • Pre heating of coils under vaccum as to achieve desired compression height &
contacts max shrinking of coils.
• Skid under base • Premali wood clamping rings for uniform compression of primary & secondary
• Inspection Cover winding.
• On Load Tap Changer / Off • Coil clamping screws for sustaining high mechanical strength due to short
Circuit Tap Changer circuit forces.
• RTCC Panel with automatic • Adequate ducts between layers, coils, discs for max oil flow & reduced hot spot
voltage regulator (AVR) temperature.

7 8
CAST RESIN
DRY TYPE TRANSFORMER

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Duty, Type Outdoor / Indoor Ground Mounted Type At TELAWNE casting method of these transformers is obtained with the combined
• H.V. Cable box.
action of vacuum GENERAL DETAILS
and temperature. The casting method makes it possible to
• L.V. Cable box with bus bar or Voltage Class UPTO 33 kV assure void-free epoxy penetration of both the inner layer and between turn
bus duct insulation. These Transformers are specifically needed in distribution network for
No of Phases 3 Phase
• Off circuit tap links feeding basements or stilts of high-rise buildings, hotels, Malls, stadium, air ports,
Frequency 50/60 Hz chemical & refinery plants. Following are the dimensional, weight & quantity
• Under carriage with four
Vector Group Dyn1 or Dyn5 or Dyn11 or any specific details along with standard losses for conventional 11KV, (off circuit Type) Cast
bi-directional rollers
Resin Transformer (CRT).
• Earthing terminals. Insulating Fluid F or H with Temp Rise of 90 or 115 Deg C or as
per customer requirement SR. RATING OVERALL DIMENSIONS (MM) LOSSES (W) TOTAL WT..
• Rating and diagram plate
Class of Insulation Class A NO. (KVA) LENGTH (L) BREADTH (B) HEIGHT (H) NO LOAD LOAD (KGS)
• Lifting lugs for complete 1 100 1400 1500 1500 400 1600 925
transformer Tap Changer Off Circuit or On Load
2 150 1500 1600 1600 500 2400 1050
• Tapping link operation door Tapping Range + 2.5% X 2 for OCTC or + 2.5% X 2 & - 2.5% X
3 200 1600 1700 1700 600 3000 1400
6 for OLTC or as per customer requirement
• Enclosure with louver panels 4 250 1700 1800 1800 700 3500 1550
Winding Material Aluminium or Copper with multi paper
• Canopy covering 5 315 1750 1900 1900 950 4400 1650
6 400 1850 2100 2000 1200 4750 2100
• Base channel – 2 Nos. Applicable Standards IS 11171, IEC 60726
7 500 1900 2200 2200 1450 5200 2300
• Separate neutral bushing Painting Powder coated with RAL 7032 shade or as 8 630 2000 2400 2300 1600 6000 2600
on LV side. per customer requirement
9 750 2100 2500 2350 1800 7000 3200
• Paint: Powder coated
10 1000 2200 2600 2400 2200 9500 3400
with RAL 7032 Shade
11 1250 2300 2700 2450 2600 11500 3600
12 1600 2350 2800 2500 3200 13500 4000
SAFETY FEATURES
13 2000 2400 3000 2600 3800 16500 4450
R Environment Friendly 14 2500 2500 3200 2700 4500 20000 5000

R Fire Resistance 15 3000 2600 3400 2800 5000 23000 6500

R Non-Hygroscopic *Dimensions and weight & losses may vary for any specific or special requirement.

R OPTIONAL FITTINGS R ASSURED FEATURES


• Windings are electrically balanced to minimize axial short circuit forces.
• RTD with A/T contact
• Marshalling box with control wiring • Coils are held rigidly in place between insulators clamped to the upper and lower
core frames under high compression.
• On Load tap changer
with RTCC panel with AVR • Precise casting under vacuum enuring low partial discharge.
• Forced Cooling arrangement • Smooth surface finish and robust construction of MV & LV cast Coils.
• Neutral Current Transformer • Adequate ducts between coils, discs for maximum air flow and reduced hot spot
temperature.

• Step-lap designed CRGO laminations for lower losses and excitation current.

9 10
VACUUM PRESSURE IMPREGNATED
DRY TYPE TRANSFORMER

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Duty, Type Outdoor / Indoor, Pole or Ground Mounted We TELAWNE manufacture both hermetically sealed, corrugated radiator type and
• H.V. Cable box
GENERAL
conventional open enclosure DETAILS
type vacuum pressure impregnated dry Transformers.
• L.V. Cable box with Bus bar Voltage Class Upto 22 kV These Transformers are specifically needed in distribution network for feeding
or Bus duct basements or stilts of high-rise buildings, hotels, Malls, stadium, air ports,
No of Phases 3 Phase
• Off Circuit Tap links chemical & refinery plants. Following are the dimensional & weight details along
Frequency 50/60 Hz with standard losses for conventional 11kV, Dry Type (VPI) Transformer
• Under carriage with four (off circuit Type).
Vector Group Dyn1 or Dyn5 or Dyn11 or any specific
bi-directional Rollers
Class of Insulation F or H with Temp Rise of 90 or 115° C or as SR. RATING OVERALL DIMENSIONS (MM) STANDARD LOSSES (W) TOTAL WT.
• Earthing terminals
per customer requirement NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) NO LOAD FULL LOAD (KGS)
• Rating and diagram plate
Tap Changer Type Off Circuit or On Load 1 100 1400 1500 1500 400 1600 925
• Lifting lugs for complete 2 150 1500 1600 1600 500 2400 1050
Tapping Range ±2.5% X 2 for OCTC or + 2.5% X 2 & - 2.5% X
Transformer 6 for OLTC or as per customer requirement 3 200 1600 1700 1700 600 3000 1400
• Tapping Link operation Door Aluminium or copper with multi paper 4 250 1700 1800 1800 700 3500 1550
Winding Material
NOMEXcovering
• Enclosure with Louver Panels 5 315 1750 1900 1900 950 4400 1650
Applicable Standards IS 11171, IEC 60726 6 400 1850 2100 2000 1200 4750 2100
• Canopy
Enclosure Painting Powder coated with RAL 7032 shade or as 7 500 1900 2200 2200 1450 5200 2300
• Base Channel-2 Nos.
per customer requirement
8 630 2000 2400 2300 1600 6000 2600
• Separate Neutral bushing on
LV side 9 750 2100 2500 2350 1800 7000 3200
10 1000 2200 2600 2400 2200 9500 3400
• Paint: Powder Coated with RAL
7032 shade 11 1250 2300 2700 2450 2600 11500 3600
12 1600 2350 2800 2500 3200 13500 4000
• Hinged Windows for inspection
of core and windings 13 2000 2400 3000 2600 3800 16500 4450
14 2500 2500 3200 2700 4500 20000 5000
15 3000 2600 3400 2800 5000 23000 6500
SAFETY FEATURES
*Dimensions and weight & Losses may vary for any specific or special requirement.
R Environment Friendly
R OPTIONAL FITTINGS R ASSURED FEATURES
R Fire Resistance • RTD with A/T contact • Windings are electrically balanced to minimize axial & radial short circuit forces.
R Non-Hygroscopic • Marshalling box with control wiring • Coils are held rigidly in place between insulators clamped to the upper and lower
core frames under high compression.
• On Load Tap Changer with RTCC
Panel with AVR • Polyester resin or thixotropic epoxy resin or silicon varnish impregnation as per
the application is used.
• Forced Cooling arrangement
• High temperature resistant materials are used including Nomex papers, silicone
• Neutral Current Transformer coated fibreglass and pressure sensitive glass tape.
• Space heaters for core & windings • Adequate ducts between coils, discs for maximum air flow and reduced hot spot
temperature.
• Step-lap designed CRGO laminations for lower losses and excitation current.

11 12
UNITISED
SUBSTATION

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Medium Voltage Compartment Unitised substation are designed for locations where space and safety is a concern,
• M.S./ CRC Sheet fabricated
Enclosure as per IS 14786 MV Switchgear 3.3 to 33 kV population density GENERAL
is high, suchDETAILS
as urban centre. Unitised substation is divided in
three section or compartment— Medium Voltage, Transformer and Low Voltage
Type of Switchgear LBS / SFU / Circuit Breaker / RMU
• Load Balancing Lifting Hooks Switchboard. Unitised substations are designed in accordance with IS 14786 / IEC
Insulation Medium SF6 Gas or Vacuum
• Collapsible hinge mounted 61330 standards with degree of protection for IP 23 Transformer and IP 54 for MV &
Tripping Fuse / Relay LV compartments or as per customer requirement.
doors
Short Circuit Rating 21 KA or as per customer requirement
• Perforated sheet & Air Following are the dimensional and weight details for a typical 11kV, Unitized
ventilation louvers in Transformer Compartment substation with off circuit type oil cooled Transformer.
Transformer section Type of cooling Oil Immersed / Dry Type
SR. Rating Overall dimensions (mm) Approx WT.
• Easy removable rain water Rating 100 to 2000 kVA
protection canopy NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) (KGS)
Voltage 3.3 to 33/0.433 kV or any specific
• For safety doors with alarm & Phase / Frequency 3 Phase / 50 or 60 Hz. 1 100 to 250 2600 1800 2000 2500
tripping circuit Vector Group Dyn1 or Dyn5 or Dyn11 or any specific. 2 315 to 630 2800 2000 2200 3800
• Inter connecting MV & LV Low Voltage Compartment
3 750 to 1000 3000 2200 2400 5200
cables & Bus bars ACB's, MCCB's
LV Switchgear
4 1250 to 2000 3200 2400 2600 7000
• Powder coated paint, Shade - Current Rating Up to 4000 Amps
RAL 7032 or as per customer 440 Volts *Dimensions and weight may vary for any specific or special requirement.
Voltage
request
No. of Poles 3/4
• Illuminating lamps with MCB
Short Circuit Rating 36 kA or as per customer requirement R APPLICATIONS R ASSURED FEATURES
Airport IT Industry M.V. Compartments Transformer Compartment L.V. Compartment
MV RMU/ VCB/ SFU On Load Tap Changer with L.T. microprocessor
SPECIAL FEATURES R.T.C.C. panel & AVR based trip unit

H.T. Metering/ Load Pressure Release valve L.T. MFM / Load


R Completely Factory built manager manger
R Superior Aesthetics Refineries Mines Annunciator & Power W.T.I & O.T.I. with Alarm Feeder Pillar
pack & Trip contacts (HRC fuse / MCCB Based)
R Convenience in portability
Earth fault, over Magnetic Oil Gauge with APFCR Panel with
R Readyto install & Commission
current relay low level contacts capacitor Bank
R Compact in size Scada or P.L.C Bucholz Relay with Alarm L.T. Earth fault & Over
R Minimal maintenance compatible & Trip contacts current relay
Theatre / Mall Construction Site
R Suitable for rooftop &
Basement
R Tamper proof

13 14
PAD MOUNTED
SUBSTATION

BASIC COMPONENTS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Medium Voltage Compartment Pad Mounted Substations are designed for use in distribution application as well as
• MS/ CRC Sheet fabricated
Enclosure as per IS 14786 MV Switchgear Upto 22 kV for dedicated loads.GENERAL DETAILS
Pad mounted substation's are easy to install and are of low
cost. These are basic & simplest configuration required for distribution substation.
Type of Switchgear LBS / SFU / Circuit Breaker / RMU / VCB
• Load Balancing Lifting Hooks Pad Mounted Substation are designed in accordance with IS 14786 / IEC 61330
Insulation Medium SF6 Gas or Vacuum
• Collapsible hinge mounted standards with degree of protection for IP 54 or as per customer requirement.
Tripping Fuse / Relay
doors
Short Circuit Rating 21 kA or as per customer requirement Following are the dimensional and weight details for a typical 11kV, Pad Mounted
• Corrugated tank for Substation.
Transformer Transformer Compartment
Installation Outdoor / Indoor Ground Mounted SR. Rating Overall dimensions (mm) Approx WT.
• Safety door switches
Type of cooling Oil Immersed / Dry Type NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) (KGS)
• Interconnecting MV & LV Rating 63 to 1000 kVA
Bus bars 1 100 to 250 1600 2000 1800 2000
Voltage 6.6 to 22/0.433 kV or any specific
• Powder coated paint, 2 315 to 630 1800 2200 2000 3200
Phase / Frequency 3 Phase / 50 or 60 Hz
Shade - RAL 7032 or as per
customer requirement Vector Group Dyn1 or Dyn5 or Dyn11 or any specific 3 750 to 1000 2000 2400 2200 4000

Low Voltage Compartment *Dimensions and weight may vary for any specific or special requirement.
LV Switchgear ACB’s, MCCB’s or HRC Fuse
Current Rating Upto 2000 Amps R OPTIONAL FEATURES
Voltage 440 Volts • M.V. Drawout type breaker • Pressure Release Valves
No. of Poles 3/4
• M.V. Earth Fault (E/F), Over Current • M.V. / L.V. orientation,
Short Circuit Rating 36 kA or as per customer requirement (0/C) relay made to suit

• Aluminum or copper winding • L.T. Micro-processor based Trip unit


SPECIAL FEATURES R SINGLE LINE DIAGRAM • Stainless Steel Tank • L.T. MFM / Load manager

R Completely Factory built • DGPT Relay • L.T. Earth Fault (E/F),


Over Current (O/C) relay
R Superior Aesthetics

R Convenience in portability Specification Oil Type Dry Type


R Ready to install & Commission Tapping Off Circuit Switch Off Circuit Links
Insulation Class ‘A’ ‘F’
R Compact in size
Temperature Rise Oil / Winding up to Winding up to 130°C
R Minimal maintenance 55/65°C

Temperature Protection OTI, WTI RTD

15 16
TOWER
SUBSTATION

BASIC COMPONENTS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Medium Voltage Compartment Tower Substations are designed for use in distribution application as well as for
• MS/ CRC Sheet fabricated MV Switchgear Upto 22 kV
GENERAL
dedicated loads. Tower DETAILS
substation’s are easy to install and are of low cost. These
Enclosure as per IS 14786 are basic & simplest configuration required for distribution substation. Tower
Type of Switchgear LBS / SFU / Circuit Breaker / RMU / VCB Substation are designed in accordance with IS 14786 / IEC 61330 standards with
• Load Balancing Lifting Hooks Insulation Medium SF6 Gas or Vacuum degree of protection for IP 54 with ONAN transformer & with Dry / Cast resin
transformer only transformer enclosure with IP 23 or as per customer requirement.
• Collapsible hinge mounted Tripping Fuse / Relay
doors Short Circuit Rating Upto 20 kA or as per customer requirement Following are the dimensional and weight details for a typical 11kV, Tower
Substation
• MV/LV switchgear enclosure Transformer Compartment
with IP54 SR. Rating Overall dimensions (mm) Approx WT.
Installation Outdoor / Indoor Ground Mounted
• Corrugated tank for ONAN Type of cooling Oil Immersed / Dry Type NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) (KGS)
Transformer with IP 54 Rating 63 to 1000 kVA
1 100 to 250 1800 1800 3800 3000
• Dry & Cast resin transformer Voltage 3.3 to 22/0.433 kV or any specific
enclosure with IP 23 2 315 to 630 1800 2000 4000 4000
Phase / Frequency 3 Phase / 50 or 60 Hz
• Safety door switches Vector Group Dyn1 or Dyn5 or Dyn11 or any specific 3 750 to 1000 2000 2000 4400 5250

• Inter connecting MV & LV Low Voltage Compartment


cables/ Bus bars *Dimensions and weight may vary for any specific or special requirement.
LV Switchgear ACB’s, MCCB’s or HRC Fuse
• Powder coated paint, Current Rating Upto 2000 Amps
Shade – RAL / IS-5 or as per R OPTIONAL FEATURES
customer requirement Voltage 433 Volts
 M.V.Drawout type breaker  L.T Earth Fault (E/F), Over Current
No. of Poles 3/4 (O/C) relay
 M.V. Earth Fault (E/F), Over
Short Circuit Rating Upto 50 kA or as per customer requirement Current(O/C) relay  HT metering / Load manager
 Aluminum or copper winding  SCADA or PLC compatible
 Stainless Steel Tank  Feeder pillar (HRC fuse / MCCB based)
SPECIAL FEATURES  DGPT Relay  Dry type / Cast resin transformer
R Completely factory built  Pressure Release Valves  For ONAN transformer, PRV,MOG,
WTI / OTI & Bucholz relay
 M.V./L.V. Orientation, made to suit
R Superior Aesthetics  For Dry / CRT transformer, space
 L.T. Micro-Processor Based Trip unit
heaters, surge arresters, Temp.
R Convenience in portability  L.T. MFM/ Load Manager scanner
R SINGLE LINE DIAGRAM
R Ready to install & Commission

R Compact in size Specification Oil Type Dry Type


Tapping Off Circuit Switch Off Circuit Links
R Minimal maintenance
Insulation Class ‘A’ ‘F’
Temperature Rise Oil / Winding up to Winding up to 130°C
55/65°C

Temperature Protection OTI, WTI RTD

17 18
CONTAINERISED SOLAR
SUBSTATION

STANDARD FITTINGS R TECHNICAL SPECIFICATIONS R PRODUCT DIAGRAM R GENERAL DETAILS


Medium Voltage Compartment Containerised solar substation are designed for clustered solar parks where space
• M.S./ CRC Sheet fabricated
Enclosure as per IS 14786 MV Switchgear 11 to 33 kV
GENERAL
and safety is a concern, and areDETAILS
of capacity 500KW to 20MW projects. Container-
ized substation is divided in three section or compartment— MV Breaker, Trans-
• Load Balancing Lifting Hooks Type of Switchgear SFU / Circuit Breaker / RMU SF6
former and Inverters with DCDB. Containerised substations are designed in accor-
• Collapsible hinge mounted Insulation Medium Gas or Vacuum
dance with IS 14786 / IEC 61330 standards with degree of protection upto IP 43 for
doors Tripping Fuse / Relay Transformer and Inverters compartments & upto IP 54 for MV breaker compart-
• Rain water protection IP 54 for Short Circuit Rating 21 kA or as per customer requirement ment.
Breaker compartment
Transformer Compartment Following are the dimensional and weight details for a typical 11kV, Containerized
• IP 43 for Transformer
/ Invertors compartments Type of cooling Dry Type VPI / Cast Resin substation with off circuit type Dry / Oil Cooled Transformer.
Rating Up to 2500 kVA
• For safety doors with alarm & SR. Rating Overall dimensions (mm) Approx WT.
tripping circuit Voltage 11 or 33/0.350-0.350 kV or any specific
NO. (kVA) LENGTH (L) BREADTH (B) HEIGHT (H) (Tonnes)
• Inter connecting MV & LV Phase / Frequency 3 Phase / 50 or 60 Hz.
cables or bus bars from YNd11d11 or Dy11y11 or any specific. 1 500 to 1250 6000 2400 2450 10
Invertors to Transformer, Vector Group
Transformer to MV Breaker Low Voltage Compartment 2 Up to 2500 12000 2400 2450 15
• Powder coated paint, for HV& LV Switchgear ACB's, MCCB's with DCDB
LV equipments *Dimensions and weight may vary for any specific or special requirement.
Current Rating 200A & above in multiple range
• Epoxy / PU paint, Shade - RAL 300 to 440 Volts in multiple Inputs
Voltage
9003 or as per customer
to Transformer.
R OPTIONAL FITTING
request
No. of Poles Single to Multiple. Robust & Compact Design M.V. Compartments Transformer Compartment L.V. Compartment
• Illuminating lamps with MCB
Short Circuit Rating ABB or SMA or Bonfiglioli or any MV RMU/ VCB/ SFU Dry type (VPI / Resin Cast) / L.T. microprocessor
as per customer requirement Oil Cooled. based trip unit

H.T. Metering/ Load Copper wound or Aluminum Output from 300 to 400
SPECIAL FEATURES manager wound Volts

Annunciator & Power Scanner with RS 485 port & Blower RS-485/ MODBUS/
R Completely Factory built pack control, Alarm & Trip contact TCP,CAN,PROFIBUS
R Superior Aesthetics Earth fault, over 3 or 4 winding transformers Efficiency up 98.6%
current relay
R Convenience in portability
R SINGLE LINE DIAGRAM Scada or P.L.C Input: 300 to 400 V or any as per Innovative two zone &
R Ready to install &Commission
TRANSFORMER
compatible requirement Amb. Protection system
1250 (625+625)KVA

R Compact in size
11/0.36-0.36KV

DELTA
0.36 KV

R Minimal maintenance
STAR
11KV R APPLICATIONS
DELTA N
RMU 12KV
0.36 KV

R Ideally Suitable for on Grid

TO GRID
SUPPLY
Solar Projects
CT
INVERTER 1

INVERTER 2
PT
AMMETER
500KW

500KW
R Tamper proof ES TARIFF
METER


-

-
D CDB

R Numerical Reverse Power


LIVE LINE
INDICATOR

Protection Relay PROTECTIVE


RELAY

PVR SOLAR BANK

R Numerical 3 pole Differential


Relay

19 20
GLOBAL
PRESENCE

GOVERNMENT INDUSTRIES Power Utilities I Government Undertakings I Steel I Healthcare I Renewable Energy I Oil and gas I Hospitality CORPORATES
UTILITIES & PUBLIC Real Estate I Textile I Engineering I Food and Beverage I Automobile I Telecom I Information & Technology.
CATERED & MULTINATIONALS
SECTOR UNITS

Maha Discom / Transco


(MSEDCL)/ (MSETCL)

Karnataka Power
15+
COUNTRIES
150+
EMPLOYEES
3000+
INSTALLATIONS
38000+
SQUARE FEET
Siemens Ltd

IVRCL
Infrastructure
Co. Ltd. (KPCL) Project Ltd

Southern Railway Gammon


India Ltd
Bharat Heavy 6300 kVA Power Trans- 3600 kVA Distribution
Electricals Ltd. (BHEL) former, Afghanistan. Transformer ,Bangladesh. Rolls Royce
Energy Ltd
National Thermal
Power Corp. (NTPC) Jindal Steel Ltd
2500 kVA Distribution
National Hydroelectric Transformer ,Philippines. Larsen & Toubro Ltd
Power Corp. (NHPC)
150KVA Syria Vadilal
Ordnance Factories Distribution Afghanistan Industries Ltd
Transformers Saudi Arabia Bangladesh
in Higleig,
Oil & Natural Gas Sudan Oman India Tata Power Ltd
Sudan
Corp. (ONGC)
Venezuela Liberia Togo Philippines Shreem
Madhya Pradesh Power Nigeria Ethiopia Electric Ltd
Transmission Co. Ltd. Ghana Kenya
(MPPTCL) Rwanda
Congo ABB LTD.
Tanzania
Angola
Kerala State Electricity Harsha Abakus
Board Ltd. (KSEB) Zambia Solar Pvt Ltd.

Telangana State Electricity 1500kVA USS 3MVA Power 500KVA Dry Type USS, 10.5000 KVA, Gamesa Renewable
Substation for Amponsah Transformer for Arcelor for INOX, Jamnagar, Power X'mer Sagar Sai
Transmission Co. Ltd. Pharmaceuticals, Ghana Mittal Mines, Liberia
South Gujrat Enterprises, Nirmal Nagar, Pvt. Ltd.
(TSETCL) Africa Nagpur

21 22

Potrebbero piacerti anche