Sei sulla pagina 1di 2

®

DSEGenset

DSE7110/20 MKll ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY

AUTO START & AUTO MAINS FAILURE BS EN 61000-6-2


EMC Generic Immunity Standard for
the Industrial Environment
CONTROL MODULES BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

The DSE7110 MKll Auto Start Electronic J1939 (CAN) and non- Through USB Communication both OPERATING TEMPERATURE
BS EN 60068-2-1
Control Module and the DSE7120 electronic MPU and alternator modules can be easily configured Ab/Ae Cold Test -30 oC
MKll Auto Mains (Utility) Failure sensing engine support for diesel, using the DSE Configuration Suite BS EN 60068-2-2
Control Module are suitable for a gas and petrol engines all in one PC Software or can be fully Bb/Be Dry Heat +70 oC

wide variety of single gen-set variant. With a number of flexible configured through the module's VIBRATION
applications. inputs, outputs and protections, the front panel editor. BS EN 60068-2-6
Ten sweeps in each of three
modules can be easily adapted to major axes
Monitoring engine speed, oil suit a wide range of applications. All DSE products are supported by 5 Hz to 8 Hz @ +/-7.5 mm,
pressure, coolant temperature, the DSE global technical support 8 Hz to 500 Hz @ 2 gn

frequency, voltage, current, power Compehensive power metering for team which gives our customers HUMIDITY
and fuel level, the modules will give both generator and load is available and end users access to 24 hour BS EN 60068-2-30
Db Damp Heat Cyclic 20/55 oC
comprehensive engine and (kW, kV A, kV Ar, pf). A real time system help and advice. @ 95% RH 48 Hours
alternator protection. This will be clock allows scheduling while a 50 BS EN 60068-2-78
indicated on a large back-lit LCD event log provides extensive event Cab Damp Heat Static 40 oC
@ 93% RH 48 Hours
icon display via an array of warning, interrogation.
electrical trip and shutdown alarms. SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 gn in 11 mS

DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the supplied sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

6 4 4

USB CONFIGURABLE DC OUTPUTS ANALOGUE SENDERS / EMERGENCY DC POWER


PORT INPUTS DIGITAL INPUT STOP SUPPLY 8-35V

DEUTZ
DSE7110/20 MKll ISUZU
PERKINS
CATERPILLAR
MTU
7 VOLVO
CUMMINS
OTHER SCANIA

MAINS (UTILITY) N/C VOLT FREE GENERATOR / N/O VOLT FREE GENERATOR CHARGE FUEL & START ELECTRONIC
SENSING OUTPUT LOAD CURRENT OUTPUT SENSING ALTERNATOR OUTPUTS ENGINES &
(DSE7120 MKlI) (Flexible with CAN) MAGNETIC PICK-UP

VOLTS VOLTS
D+
W/L +

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N

ISSUE 1
®

DSEGenset

DSE7110/20 MKll SPECIFICATION

DC SUPPLY

AUTO START & AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING


8 V to 35 V Continuous

CONTROL MODULES CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
FEATURES supply recovers to 5 V. This is achieved
without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.
DSE7120 MKll
MAXIMUM OPERATING CURRENT
290 mA at 12 V, 140 mA at 24 V

MAXIMUM STANDBY CURRENT


75 mA at 12 V, 40 mA at 24 V
DSE7110 MKll
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V

GENERATOR & MAINS (UTILITY)


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

MAGNETIC PICKUP
VOLTAGE RANGE
+/- 0.5 V to 70 V

FREQUENCY RANGE
10,000 Hz (max)

INPUTS
DIGITAL INPUTS A TO F
Negative switching

KEY BENEFITS KEY FEATURES • Configurable staged loading ANALOGUE INPUTS A TO C


Configurable as:
• Automatically transfers between • Large back-lit icon display outputs
0 Ω to 480 Ω
Negative switching digital input
mains (utility) and generator • Heated display option available • CAN, MPU and alternator
(DSE7120 MKll only) • Fully configurable via the fascia speed sensing in one variant
ANALOGUE INPUT D
• Hours counter provides accurate or PC using USB • 3 engine maintainance alarms Configurable as:
information for monitoring and communication • Engine speed protection Negative switching digital input
0 V to 10 V
maintenance periods • Extremely efficient power save • Engine hours counter
0 Ω to 480 Ω
4 mA to 20 mA
• User-friendly set-up and button mode • Engine pre-heat
layout for ease of use • 3 phase generator sensing • Engine run-time scheduler
OUTPUTS
• Multiple parameters are • 3 phase mains (utility) sensing • Engine idle control for starting & OUTPUT A & B (FUEL & START)
monitored & displayed (DSE7120 MKll only) stopping 10 A short term, 5 A continuous,
simultaneously • Generator/load power • Battery voltage monitoring at supply voltage
• The module can be configured monitoring (kW, kV A, kV Ar, pf) • Start on low battery voltage OUTPUTS C & D
to suit a wide range of • Generator overload protection • Real time clock 8 A AC at 250 V AC (Volt-free)
applications (kW) • Fuel pump control
AUXILIARY OUTPUTS E, F, G & H
• Compatible with a wide range • Generator/load current • Configurable remote start input 2 A DC at supply voltage
of CAN engines, including tier 4 monitoring and protection • 1 alternative configuration
engine support • Fuel and start outputs • Comprehensive warning, DIMENSIONS
OVERALL
• Uses DSE Configuration Suite (configurable when using CAN) electrical trip or shutdown 240 mm x 181 mm x 42 mm
PC Software for simplified • 4 configurable DC outputs protection upon fault condition 9.4” x 7.1” x 1.6”
configuration • 2 configurable volt-free outputs • LCD and LED alarm indication
PANEL CUT-OUT
• Licence-free PC software • 4 configurable analogue/digital • Event log (50) 220 mm x 160 mm
• IP65 rating (with supplied inputs 8.7” x 6.3”
gasket) offers increased • 6 configurable digital inputs
MAXIMUM PANEL THICKNESS
resistance to water ingress • Support for 0-10 V & 4-20 mA 8 mm
oil pressure sensors 0.3”

STORAGE TEMPERATURE RANGE


RELATED MATERIALS
-40 °F to +185 °F
-40°C to +85°C
TITLE PART NO’S
DSE7110/20 MKll Installation Instructions 053-151 OPERATING TEMPERATURE RANGE
DSE7110/20 MKll Operator Manual 057-182
-22 °F to +158 °F
-30°C to +70°C
DSE7110/20 MKll Configuration Suite PC Manual 057-185

-40 °C to +70 °C
HEATED DISPLAY VARIANT

-40 °F to +158 °F

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-138/01/13 (1)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457