SHEET PAGES 1 OF 1 REV. BY CHK APPR. DATE A CCdR PAR PAR Mar-2017 0 CCdR PAR PAR Mar-2017 1 CCdR PAR PAR Jun-2017 INGENIERA DE DETALLE DE EQUIPOS Y PROCESO CL PROJECT PROJECT PARA EL PROYECTO MAQUI - ECOLAB EQ PROJECT 2016052-EC
1 TAG NO. FSL-509
2 SERVICE Stop pump P-509 A/B 3 GENERAL P&ID 2016052-PID-509 4 INFORMATION 5 6 7 FLUID Sodium Hypochlorite 16% wt 8 LINE 3"-NaClO-4J-0-5907 9 TEMPERATURE MIN / NORM / MAX, C 25 60 10 PROCESS PRESSURE MIN / NORM / MAX, kg/cm2g atm 6 DATA 3 11 FLOW MIN / NORM / MAX, m /h 25 12 OPER. SPECIFIC GRAVITY 1,26 13 OPER. VISCOSITY, cP 1,4 14 15 FLOW SWITCH TYPE Paddle 16 BOX 17 SERVICE Sodium Hypochlorite 18 FLOW DIRECTION Perpendicular to sensor 19 WETTED PARTS MATERIAL PVC o Teflon 20 ELECTRIC CONNECTION 1/2" FNPT 21 PROCESS CONNECTION 1" flanged FF 22 MAX. PRESSURE, kg/cm2g 6 3 23 SET FLOW, m /h 1,0 DESIGN DATA 24 SETTING 25 ELECTRICAL CLASSIFICATION General Purpose 26 SWITCHES VOLTAGE/RATING 24 Vdc /5A 27 TYPE SPDT 28 INSERTION LENGTH By vendor 29 TIME RESPONSE, seconds 10 30 PROTECTION IP 65 / NEMA 4X 31 INSTALLATION Outdoor 32 FUNCTION LED (STATUS) By vendor 33 34 MANUFACTURER PURCHASE 35 MODEL & MFR NUMBER INFORMATION 36 37
Rapid and Reliable HPLC Method For The Simultaneous Determination of Dihydroxyacetone, Methylglyoxal and 5-Hydroxymethylfurfural in Leptospermum Honeys