PowerFactory 2017
Release Notes
I N T EG R AT E D P O W E R S Y S T EM A N A LY S I S S O F T WA R E F O R
T R A N S M I S S I O N / D I S T R I BU T I O N / I N D U S T RY / G EN E R AT I O N / I N T EG R AT I O N O F R EN E WA B L E S
Publisher:
DIgSILENT GmbH
Heinrich-Hertz-Strae 9
72810 Gomaringen / Germany
Tel.: +49 (0) 7072-9168-0
Fax: +49 (0) 7072-9168-88
info@digsilent.de
Contents
1.1 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2.1.21 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1.22 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1.23 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.1 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.1.19 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.1.20 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
3.1.21 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.1 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
4.1.20 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.1.21 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
4.1.22 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
5.1 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
5.1.22 Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
5.1.23 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
5.1.24 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
6 PowerFactory 2017 78
6.1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
6.2.10 Miscellaneous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
6.3 Improvements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Description ID
Description ID
CGMES Converter:
Description ID
3 Grid-to-CIM: Both RegulatingCondEq.controlEnabled and Regulating- #21869
Control.enabled are now set to false in cases where a PF controller
fails the conversion.
Description ID
3 Unbalanced load flow results for reduced elements (such as breakers) are #20825
now consistent if the calculation is repeated. DIG30042
Description ID
3 IEC or VDE method: Any fault to neutral on a line is now correctly #21470
checked.
3 Calculation of idc and Iasy is now correct for IEC or VDE edition 2016 #21619
methods.
3 RT2 Analysis: Fault current calculations on breakers have been corrected #21579
by proper consideration of opposite bus-side cubicles.
3 Protection objects are now correctly checked for missing characteristic #21493
type before calculation.
3 The time-distance plot now displays and records results correctly when #20945
the Calculate Relay Tripping option for the complete short-circuit used by DIG30287
the sweep is set to Transient Values or Mixed Mode.
3 Solved angle issue for current injection from full-size converter which #21223
lead to a large initial break current in specific cases. DIG30714
Description ID
3 Calculation now yields the same results for multiple short-circuit loca- #21527
tions as one location, including under the following specific conditions: DIG31278
The system contains full-size converter stations;
The short-circuit contribution from the main network (excluding the
full-size converter station) is zero for one short-circuit location.
Description ID
3 Frequency sweep plots now correctly display the harmonic order on the #21559
x-axis. DIG30911
Description ID
3 Correct colours are now shown following a load flow calculation if a feeder #21529
is contained in another feeder. DIG26737
3 Insertion of ElmFolder objects from templates into detailed substation di- #21337
agrams now works properly. DIG31051
Description ID
3 RMS simulation: The application of a load ramp event when the option #21087
Allow load-ramp event is disabled is now correctly handled.
3 MV load: #21102
The zero-sequence transformer impedance is now correctly consid-
ered in unbalanced calculations (short-circuit, harmonics, RMS);
The harmonic load flow now correctly handles the model when a
P,Q (generation) is defined and the load is unsupplied.
3 If one QDSL model references other QDSL models as inputs or outputs, #21650
the initialisation order is now correct.
3 Series filter: DPL function GetImpedance() now returns the value for #20961
the reactance in Ohm. DIG30305
3 DC load flow using according to Primary Control: External grid and ex- #21335
tended/Ward equivalents are now correctly considered.
3 Step-voltage regulator (ElmVoltreg): Load flow: Rset and Xset (both #21205
forward- and reverse-direction) are now properly considered when Line DIG30418
drop compensation is selected for closed- and open-delta connections,
assuming that line-line volt values have been entered.
Description ID
3 The control condition for three-winding transformers is now checked fol- #21407
lowing an unbalanced load flow calculation.
- Complete revision of all WECC wind turbine model templates for model #21398
enhancements and performance improvements. WECC wind turbine DIG26663
model templates for 60Hz networks have been added.
- The following photovoltaic plant models according to WECC have been #21400
added to the templates library:
Large-scale photovoltaic plant;
3 Input signals for nominal power have been corrected in Gov Steam1 #21401
and Gov SteamIEEE 1.
Description ID
- Improvement of the following models with respect to initialisation, sim- #21402
ulation performance and robustness:
Exc AC1A
Exc AC2A
Exc AC3A
Exc AC4A
Exc AC6A
Exc AC8B
Exc AVR2
Exc AVR4
Exc DC2A
Exc PIC
Exc REXS
Exc SK
Exc ST2A
Exc ST4B
Exc ST7B
Description ID
- #21402
Gov CT1
Gov CT2
Gov GAST1
Gov GAST2
Gov GASTWD
Gov Hydro2
Gov Hydro3
Gov Hydro4
Gov HydroDD
Gov HydroFrancis
Gov HydroPelton
Gov HydroPID
Gov HydroR
Gov HydroWEH
Gov Steam1
Gov Steam2
Gov SteamEU
Oel X1
Oel X2
Pss IEEE 2B
Pss IEEE 3B
Pss PSS1
Pss PSS2B
Pss PSS5
3 Model Exc AC8B (excitation system AC8B) now considers limiting sig- #21597
nal Ve max dynamically during simulation (no longer only during model
initialisation).
Description ID
3 Scenario configuration has been made more user-friendly by allowing the #20938
addition or removal of supported attributes only.
3 Complex calculation quantities (such as real part, imaginary part, c:zline:r, #21017
c:zline:i for lines) are now correctly displayed on the Flexible Data page
of the Data Manager.
Sorting works correctly;
Balloon help now displays the sum, average, minimum and maxi-
mum values;
3 Combined projects: A combined project may now be used as the source #20832
for a new combined project.
3 The Compare and Merge Tool now considers the name as the alignment #21524
criterion for generic project folders. DIG30942
3 The graphic export now displays mirrored or rotated elements correctly in #17363
SVG format. DIG24821
Description ID
3 Contingency Analysis Report: Voltage option naming has been corrected. #21486
3 Path definition now works for 2-winding transformers with separate neutral #21664
connections.
3 Data Manager: Performance improvements when opening the column fil- #20915
ter dialog.
- Text output emitted from an external DLL is now displayed in the output #21568
window even when output is suppressed via EchoOff().
3 If only the approval status is changed, the Modified and Modified by pa- #21414
rameters are no longer modified. DIG15722
3 Thermal rating object: The short-term rating table now displays the dura- #21146
tion in seconds (e.g. 30s) when the duration is smaller than one minute.
One decimal place is displayed between 1 - 10 min. when the duration is
a non-integer value (e.g. 1.5 min).
3 Adding elements to a branch is additionally possible via Edit Data on the #21608
branch. DIG29571
Description ID
3 PSS/E import: An error message is now issued if the PSS/E file version #21021
for the sequence file (*.seq) is greater than version 32. DIG30420
Integral:
Description ID
3 The logic to determine the local and remote reference bus for HVDC #21520
elements P-setpoint adaptation has been changed in cases where
one of the two is not specified in the Integral data. This is done in
order to achieve results comparable to Integral.
3 Uniform distribution of losses for lines and transformers now sup- #21522
ported.
3 Import: #21523
CGMES Converter:
- The CGMES CIM-to-Grid Converter has been enhanced to report all #21430
existing PowerFactory elements associated with a CIM ID which could
not be linked to corresponding CIM object instances when converting
CIM to an existing Grid model.
3 The controlled side on ElmTr3 is now set correctly when converting the #21423
external tap controller.
3 Converter now exports the correct controlled node for the external tap #21421
controller on a 3-winding transformer.
3 Import now correctly handles cases of an imported model which su- #20927
persedes itself. DIG30244
Description ID
3 CIM-to-Grid: Now takes into consideration all ControlArea types (AGC, #20966
Interchange and Forecast), when controller machines are associated
with the corresponding power-frequency controller in the PowerFactory
model.
3 CIM-to-Grid: Duplicated CIM parameters (import data issues) are now #20881
considered across different CGMES profiles.
3 CIM-to-Grid: The Automatic tap changing flag is now set on individ- #20840
ual tap changers when the RegulatingControls are merged into a tap
changer controller.
CIM-to-Grid: The required control node side in the tap changer con-
troller is now set correctly.
Description ID
3 CIM-to-Grid: The Generator/motor flag of the ElmSym element is now #21114
set based on SynchronousMachine.type from the equipment profile.
CIM-to-Grid: The ElmSym.pgini and ElmSym.qgini setpoints are now
set using RotatingMachine.p and q, while taking into account the Gen-
erator/motor flag of ElmSym element.
CIM-to-Grid: The Generator/motor flag of ElmAsm elements is now
set based on the sign of RotatingMachine.p, due to the ElmAsm.pgini
parameter not accepting negative values.
Grid-to-CIM: The SynchronousMachine.type is now set based on
theGenerator/motor flag of ElmSym element. The SynchronousMa-
chine.operatingMode is set based on the sign of ElmSym.pgini.
Description ID
3 Grid-to-CIM: BusbarSection and Junction CIM elements are now re- #21157
tained when converting to the bus-branch model.
3 Grid-to-CIM: Now sets missing SSH data for an external shunt con- #21433
troller that is out of service, when only EQ model is used in the addi-
tional archive.
- CIM Data Validator and Editor: Now support custom (non-CGMES) #20872
CIM profiles.
3 CIM Data Export: Now uses upper-case letters for the UTF-8 encoding #21583
declaration in the exported XML file headers.
3 CIM ENTSO-E 2009 Export (Extended Ward equivalent): The value #20900
for the internal model dummy busbar is now exported with a correct DIG30089
value.
Description ID
3 Executing the ComExit command in a headless engine session now ter- #21629
minates the application correctly.
3 Two different objects may no longer be assigned the same name using #21320
SetVal().
Description ID
3 Setting the row of a non-string array with SetVal() is now working again. #21484
DIG31211
3 Fixed DPL problem arising when using PowerFactory API from an exter- #21183
nal DPL function (digdplfun.dll).
3 Improved error messages for invalid interface variables such as parame- #21569
ter, states, etc.
3 The function CopyData() has been improved to correctly handle the #21255
scheme status of an object.
3 DPL: Resolved parsing problems when adding master script as external #21312
object of a sub-script. DIG30988
3 DPL: Reintroduced old names .NOT., .Not., etc, for logical .not. op- #21460
erator. In addition, the case-insensitive check for other Boolean operators DIG31052
such as .and., .or. and others has been reintroduced.
Description ID
3 DPL: An encrypted script may again be selected as a remote script. #21462
DIG31164
Description ID
3 Single time phase contingency analysis now yields consistent results #21027
when the same breaker is opened/closed in several contingencies. DIG30423
3 In extremely large projects (i.e. containing > 231 objects in the database) #21285
parallel contingency analysis now writes correct object IDs to the result DIG30891
file.
Description ID
3 Updates of scripts or parameters in QDSL types are now correctly con- #20867
sidered in subsequent calculations.
Description ID
3 Writing Quasi-Dynamic equations can now be done using the following #21211
syntax:
state. =...
state:dt =...
this:s:state:dt =...
State and result variables of QDSL models are now correctly re-
stored after these kinds of events or a divergent step;
The Quasi-Dynamic equations script is now executed only once per
time step.
Description ID
3 The station controller is now correctly treated as being inside the bound- #21425
ary even if it contains an empty or switched-out generator. DIG31213
REI Equivalent:
3 Results are now deterministic when multiple boundary nodes exist in #21290
the same equal-potential area.
3 Valid short-circuit parameters can now be obtained for the equivalent #21292
generator which represents a REI group composed exclusively of SVC
elements.
Description ID
3 Polarizing unit with adaptive method (RMD): Currents having a value of #21417
zero are now correctly handled.
- The Protection Audit now also picks up devices which are topologically #21564
reverse to the fault location. These are considered when checking the DIG29786
device coordination and the fault-clearing time.
3 A problem affecting the position of the restrain zone in the angular differ- #21213
ential diagram (alpha plan) has been fixed. The position is now consistent DIG30815
with the Schweitzer SEL relay conventional position.
3 Protective relay distance polygonal element trip: Issue has been fixed. #20920
DIG29146
DIG30160
Description ID
- Cable Ampacity: Large segmental conductors are now treated correctly #21289
in the sheath losses calculation.
3 Cable Sizing: VDE 0298-4 module and Table 17 correction factor value #21348
updated.
Description ID
3 Rectifier/Inverter model (ElmRec): Harmonic load flow calculation for the #20859
Ideal Rectifier is now correct for the specific case when Rated Current is
selected for Harmonic currents referred to.
Description ID
3 Events are now optionally automatically considered by the following: (i) #21644
when changing the study time; (ii) Contingency Time Sweep; and (iii)
Quasi-Dynamic Simulation.
Description ID
3 Load shedding now works correctly in cases where lines have switches #21464
with different switching times on each end. DIG31093
3 Enhanced load shedding algorithm now ensures that loads (that were ini- #20895
tially interrupted) are preferred for shedding.
3 Corrected calculation of summary grid indices for IEEE 1366 considera- #21686
tion of sustained interruptions. DIG30810
Description ID
- Models with DC currents and DC voltages are now incorporated into the #21024
solution algorithm of the AC Optimal Power Flow and State Estimation. DIG29618
These optimisations can be successfully executed for grids containing DC
components.
Description ID
- Improved report for missing or non-loadable DLLs now provides a link to #20916
the affected model.
3 The ComSim function Execute now consistently returns 0 upon suc- #21298
cessful execution.
Description ID
3 Renewal of expired floating licences now takes borrow time from the .ini #20661
file settings in offline mode.
- Silent installation of PowerFactory has been improved and extended. See #21308
section PowerFactory Silent Installation Options in the Advanced Instal-
lation and Configuration Manual for further details.
3 After installation on a client machine with no local licence, the LicenceM- #20932
anager is no longer shown.
2.1.21 Documentation
Description ID
2.1.22 Examples
Description ID
- Wind Farm example (English and German): Diverse improvements in the #21394
scripts for power plant PQ diagram and VQ diagrams. DIG30410
Transmission System example: Target folder for network elements set in #21250
- network diagrams Overview, Grid and Map.
2.1.23 Miscellaneous
Description ID
3 The warning message stating that the zero sequence impedance (R0, X0) #21453
is too low is no longer issued for lines having a zero length. DIG23825
3 The Frequency Analysis command settings are now stored in the Study #21341
Case following execution.
3 Check zero impedance meshes now works properly if the system contains #21458
DC elements.
3 Parallel computing with transfer method via file: The temporary file is now #21473
deleted following the calculation.
Description ID
3 Constant-P generators with non-zero primary frequency bias now work #20442
correctly during DC Quasi-Dynamic Simulation when operating at limit. DIG28230
3 Active power is now correctly controlled based on the reference machine #20475
in DC load flow with primary or secondary control.
3 Summary variables for substations are now correctly initialised when a #20201
load flow is repeated without initialisation. DIG28811
3 Warning messages are now output when a station controller is ignored #20628
due to multiple controllers on the same generator.
Description ID
3 The execution of a short-circuit sweep with the Fault Type set to 3-Phase #20489
Short-Circuit (unbal.) no longer causes PowerFactory to terminate unex- DIG29379
pectedly.
Description ID
3 The calculation of the Measured Fault Impedance monitor variables #20689
(m:Zf, m:phizf, m:Xf, m:Rf ) has been corrected as follows:
For fault types 1Ph-N and 1Ph-N-E, the phase-to-ground value of
the affected phase is used;
For fault type 2Ph, the phase-to-phase values of the affected phases
are used.
The calculation of the Relay Impedance monitor variables (m:Zfrel,
m:phizfrel, m:Rfrel, m:Xfrel) has been corrected as follows:
For fault types 1Ph-N-E and 1Ph-N, the earth current correction is
considered;
For fault type 2Ph-E, the earth current correction is no longer con-
sidered.
The breaker loading for ANSI interrupting currents is now calculated using
the appropriate factor for all single-phase faults (1Ph-E, 1Ph-N and 1Ph-
N-E).
IEC/VDE Method:
- The Published field can now be defined using DPL or Python by either #20633
specifying the publication year itself, or via the associated Help balloon DIG29091
option number.
3 The c-factor table is now correctly considered in the system folder. #20587
DIG29516
3 The K-factor value for the minimum short-circuit calculation is now cor- #20179
rectly displayed for 2-winding transformers.
Description ID
3 Marking of energising status for branches during calculation has been #20552
improved. DIG23025
Description ID
3 Station controller with droop control: Unnecessary error message has #20651
been removed.
Description ID
- A new scripting command which centres the origin of plots is now available #20599
for all scripting modules. The method CentreOrigin can be used on all DIG29145
plots which contain the context-sensitive menu entry Centre Origin.
3 The points in time of the Quasi-Dynamic Simulation summary results are #20590
now displayed as formatted time stamps in the single line graphic.
3 The correct result file is now set on the page after closing the Edit Plots #20597
on Page dialog.
Description ID
3 Harmonics plot: Identical line styles are now used regardless of whether #20295
the plot is created via the toolbar icon or via the context-sensitive menu.
3 The deprecated FFT Plot now displays the correct graphic. #20604
DIG29625
Description ID
3 Graphics diagram: The cable line-style is now correctly applied to all ca- #20227
bles. DIG28824
3 Labels on short lines in substation diagrams are now displayed again. #20558
3 Inactive elements are now drawn behind all other elements. #20260
DIG28911
3 Single line diagram text boxes now display the Quasi-Dynamic Simulation #20588
summary results in the appropriate format.
3 Deeper zooming is now available when executing Mark in Graphic on ge- #20486
ographical diagrams.
3 The length of a new line is also measured in cases of lines being split. #20147
3 Line connected to very short terminals which are not exactly on the grid #20149
are now handled correctly. DIG28555
Description ID
- Series reactor: The following two new input signals for load flow model #20708
are now supported: Xin and Rin (reactance and resistance input).
Description ID
3 Static generator (ElmGenstat): The Q(V)-curve controlling mode now #20684
works correctly during Quasi-Dynamic Simulation. DIG29645
3 Line loads (ElmLodlvp): Line loads connected to lines initially discon- #20593
nected are now correctly considered. (Previously, they were not consid-
ered if the line was connected during a simulation.)
3 Single-phase
CT: The output signals in the EMT simulation are now mul- #20518
tiplied by 2.
3 Universal line model: Improved handling of complex poles in EMT simu- #20323
lations. DIG29052
3 Load: Dynamic loads are now correctly initialised when the dynamic load #20367
time constant is zero. DIG28716
DIG29026
PSS IEEE 4B
Updated ENTSO-E Dynamic Model Frame:
StandardSynchronousMachine (Standard Synchronous Machine
Interconnection)
Description ID
Rectifier/Inverter (ElmRec):
3 Equations for the calculation of reactive power have been improved #20827
in the unbalanced load flow calculation and in the unbalanced RMS
simulation.
Description ID
3 Foreign keys are now correctly handled by the Compare and Merge Tool. #20102
DIG25299
3 Templates can now be inserted into a single line diagram even if a project #20404
template folder does not exist. DIG29222
Description ID
3 Data boxes and their reference lines in single line diagrams can now be #20499
drawn even when the parent net element is not visible. DIG28832
3 Multi-user database: Empty tables and indexes on the database server #20153
are no longer created in cases of user-cancelled database initialisation.
3 Merge and Compare Tool: Handling and reporting in cases of Merge #20748
failed have the following improvements: DIG27011
The assignment check now detects and reports cases of parent ob-
jects which are missing after the merge;
The merge process is no longer aborted in the case of a missing
parent, rather continued and reported as Merged with errors in-
cluding a list of objects that could not be correctly merged.
3 The Combine Project function has been improved in terms of robustness. #20641
DIG28994
3 System stage management (v13.2) now correctly handles DELTA objects #20536
which are too large. DIG29052
- Tie open point circles are now more accurately represented. #20453
3 Combined Project: Project settings using different localisations are now #20564
correctly handled.
3 Housekeeping: Projects from the Recycle Bin are no longer automatically #20254
archived. DIG28894
3 The occurrence of anti-aliasing artefacts in single line diagrams with short, #20569
thick lines has been fixed.
- WMS base layers can now be hidden when composite layers are defined. #20571
Description ID
- The date and time of text messages in the output window can now be #20533
optionally displayed using millisecond resolution. DIG28953
3 Data Manager: Column filters on the Flexible Data page (i.e. for a type #20288
parameter) are now working correctly.
Description ID
3 Neplan import (edt,ndt): The number of parallel machines is now correctly #20269
considered when converting the active and reactive power. DIG28989
- New functions for scripting have been added to CimModel and CimObject #20322
types which allow adding, editing and deleting attributes and references.
Access to value, count, namespace and enumeration type of attributes
and references is also possible.
PSS/E:
3 Import: #20270
DIG27975
For switched shunt data with a blank STAT parameter; e.g. , , the DIG28909
out of service flag is now correctly set.
If an SVC controls the same bus as a generator, the SVC is now
added to the same station controller.
Description ID
3 Export: #20817
DIG24437
Now supports export of rectifiers/inverters with one connection
(ElmRecmono).
DC terminals, series capacitors/reactors, DC lines and non-3-phase
elements are no longer exported (PSS/E only supports 3-phase el-
ements).
Integral Import:
3 When importing motors, the missing values in the set mechanical #20766
power, rated power, rated power factor and efficiency are now com-
puted to ensure data consistency.
3 Performance has been optimised when the project overview window is #20796
open.
CGMES Converter:
3 The active power flow is now exchanged as the active power setpoint #20424
for VsConverters with active angle difference dependent P-droop.
3 Lines (ElmLne) are no longer moved into the boundary grid if the #20357
boundary line is set to be the EquipmentContainer of the correspond-
ing source ACLineSegment.
Description ID
3 The conversion of all controller types of a voltage source converter is #20256
now supported. Monopolar voltage and current source converters are
also supported.
3 CGMES Toolset: Improved message and error handling are now avail- #20253
able. CIM-to-Grid: The import of faulty data from CIM now offers im-
proved handling (e.g. missing BaseVoltage is reported but the affected
elements are still converted).
3 CGMES Toolset: Now loads the CIM database before converting, im- #20251
porting, or exporting CIM data for better performance.
3 New scripting functions have been added to CimModel and CimOb- #20322
ject types which allow adding, editing and deleting attributes and ref-
erences; and access to value, count, namespace and enumeration
types of attributes and references.
3 CIM-to-Grid: The angle per tap is no longer modified (i.e. rotated) if #20667
the corresponding step increment CIM data is negative.
Description ID
3 CIM-to-Grid: Now converts the tap changer control to continuous if the #20673
TapChangerControl.discrete is set to false.
3 CIM-to-Grid: The Q per Capacitor Unit is now set to 0Mvar if the Stat- #20670
icVarCompensator.capacitiveRating is zero.
3 CIM-to-Grid: A small value for Xext is now set for the ExtendedWard- #19988
Equivalent to isolate the voltage source from the bus.
3 Grid-to-CIM: SvPowerFlow.p and q data are now exported for Exter- #20200
nalNetworkInjections.
Description ID
- Grid-to-CIM: Conversion of ElmFilter to LinearShuntCompensator is #20447
now supported.
Description ID
3 Tabular filter values in tabular reports are now correctly handled. #20463
3 When changing the Study Time via the scripting interface, if multiple Ex- #20219
pansion Stages exist, the recording Expansion Stage is now selected DIG27255
based on alphabetical order.
3 When editing an element, the New Project Type selection now shows all #20576
available types.
DPL:
Description ID
3 Improved performance of exit(). #20241
3 The return code of fopen() has been corrected for specific cases. #20790
Description ID
3 Fixed an issue which could lead to incorrect evaluation of the logic matrix #20330
stored in RelLogic tripping units.
3 The reporting command is no longer called if the assistant could not find #20339
a starting point. DIG28878
3 Logic is now correctly evaluated if the sending side of a signal connected #20333
to a RelLogic unit is out of service and the first-order logic operation is
AND.
3 The offset polygonal distance zone now correctly detects whether a #20384
phase-phase fault is inside or outside the zone. DIG29146
3 In the Measurement Block type dialog the Calculate Earth Cur- #20713
rent/Voltage is now hidden when the measurement type is set to RMS
sequence current or Sequence current and voltages. The zero sequence
current and voltages are always calculated.
3 The selection of the faulted loop in cases of a Ph-Ph-Ground fault on the #20798
Fault Loop Setting page of the AEG/Alstom starting element dialog now DIG29182
works correctly.
Description ID
3 The reduced arcing current and time are now calculated correctly when #20579
the tripping time determination from Iteration is used.
3 Correct tripping times are now considered if the first step of an iterative #20544
tripping time determination found no tripping protection devices. DIG29492
3 The error message regarding incorrect input parameters at accessible lo- #20226
cations for IEEE and DGUV calculations is now correctly displayed. DIG28829
3 Logic is now correctly evaluated if the sending side of a signal connected #20333
to a RelLogic unit is out of service and the first-order logic operation is
AND.
Description ID
Description ID
Transfer Capacity:
3 The Scenario Scheduler is now correctly handled during the calcula- #20618
tion.
Description ID
- Circuit breakers outside feeders are now checked for thermal constraints. #20420
Description ID
3 C-Interface function gradlim const now behaves like DSL special func- #20479
tion gradlim const for any number of function evaluations.
3 The size of the internal buffer is now checked before reading a value. #20346
3 The logic used to load or reload ElmFile has been optimised. #20693
3 The history time (thist) is now used as the current time for the file load #20450
outside the simulation loop.
Description ID
3 Licence warning messages are no longer shown for expired, time-limited #20296
modules. DIG29020
3 The creation of a desktop short-cut can now be disabled for silent instal- #20632
lations.
Description ID
3 The link to the French Getting Started document in the DVD autostart #20232
menu is now active.
3 Versions which should be ignored during the application update check #20327
are now only considered in the automatically-executed check at startup.
Manual checks always report a new version (provided that one exists)
independent of the ignore settings.
- The location of the license activation file can now be configured in the .ini #20736
file.
3.1.19 Documentation
Description ID
3.1.20 Examples
Description ID
3.1.21 Miscellaneous
Description ID
3 Improved handling of file format errors of the time characteristic (Cha- #20566
Time). DIG27846
3 XML export: XML files are now readable only after the XML export has #19469
finished.
3 The PFM Master Station menu entry Jump to is now available for Local #20619
Access Station (LAS) projects.
3 The automatic ComTrade import now only creates the IntComtrade object #20611
if all corresponding .dat or .cfg files are available on the disk.
- The measurement file issues a warning if missing data samples (accord- #20584
ing to the ComTrade standard) are found while being used as simulation
input.
3 The Create new plot wizard available in the Master Station Profile no #20568
longer overwrites existing plots.
Description ID
3 Enhanced divergence checks for load flow based calculations and dy- #19646
namic simulation.
3 Solved memory leak in load flow (without flat-start) regarding net LV-PVs #19625
controlled with cosphi(P) characteristics. DIG27920
3 Enhanced stability of linear solver used within calculations such as load #19622
flow, short-circuit and dynamic simulation. Previously, in very rare cases
(when equilibration was used) invalid numbers could have been generated
by this solver.
3 Calculation quantities are now updated for all parallel feeders. #19883
Description ID
- DC Short-Circuit: GUI for the rectifier element has been enhanced by #19942
separating the IEC/VDE and ANSI/IEEE input parameters.
3 Input parameter validity check enhanced for the rectifier element. #20066
- IEC 60909 method: Now supports the latest edition release from 2016. #19640
Further information can be found in the Whats New document.
3 Using the IEC or VDE method and calculating 1-Phase, Neutral to Ground #19666
fault is now handled correctly.
3 The usage of the voltage factor c for the IEC/VDE method is now fully #19927
flexible, allowing the user to modify the tabular values. DIG26632
3 IEC/VDE breaking current designation for the German localisation has #19916
been enhanced.
Description ID
- The dispatch event is now supported by rectifier and PWM converters. #20030
DIG28027
3 Contingency report: ASCII report for Loading violations and Loading #19693
violations per Case is now correctly issued in the output window if the
highest branch loading is to be reported.
Description ID
3 Removed the warning message during network reduction when a two- #19750
circuit tower has only one line selected. DIG27265
3 In cases where the remote Q-measurement will be reduced but the con- #19720
troller remains (or vice versa), an error is now printed before network re- DIG26661
duction.
Description ID
3 The automatic scaling of the y-axis now also works for a combination of #19765
plot and y2 plots.
3 The Chart option in the plots dialog is now handled correctly. #20007
3 Eigenvalue information is now correctly shown when the selected mode #19670
is edited in the Mode Phase Plot and Mode Bar Plot dialog. DIG27321
Description ID
3 User-defined results (IntCalcres) are now supported for ComTrade. #20059
Description ID
3 Branch insertion now works for geographic diagrams without projection. #19639
- Improved default values for the zoom level visibility limits for new geo- #20003
graphical diagrams.
Description ID
3 Shunt controller (ElmShntctrl): The controller now works correctly when #20155
used in the quasi-dynamic simulation.
3 Complete short-circuit without load flow initialisation: The tap/step posi- #20129
tion (for transformers or shunts) is now correctly considered.
3 Asynchronous machine configured as DFIG: Active power limits are now #19819
correctly considered when dispatch active power (pset) is controlled via a
QDSL model.
Description ID
3 Low-voltage load with partial loads: The active power of the night storage #19820
heater is now correctly considered when the partial load is out of service. DIG27784
3 Shunt controller: For load flow calculations with automatic tap adjust- #19821
ments of shunts: Initialisation is now correct for unsupplied shunts. DIG22709
3 Reactive power of the static var system is now correctly reported in the #19675
Control Condition Check following a load flow.
3 An error message is now printed in cases of disconnected lines with Typ- #19747
Geo but with no conductor type. DIG28228
3 2-winding transformer using a DSL model for automatic tap adjustment: #19729
Access to parameters ntpmn, ntpmx (min., max tap position) is now sup- DIG27995
ported again.
3 For conductor types using the skin effect, PowerFactory now correctly #19538
handles rare cases of numerically invalid results.
3 Revision of ENTSO-E Dynamic Models (PSS): Pss PSS2ST: Updated pa- #20072
rameter description (vardef ) for input selector.
Gov HydroIEEE 2
Gov HydroPID
Gov HydroR
Description ID
3 PWM - Modular Multilevel Converter (ElmVsc): The arm reactor is now #20049
correctly considered in harmonics and the complete short-circuit calcula-
tion, when the Const V. option has been selected.
Description ID
3 The Adapt Width capability of text boxes in single line diagrams has been #19369
improved. DIG27579
3 Add-on Modules can now handle overlapping attribute names correctly. #19894
- Newly-created feeder diagram now adopts settings from the currently- #19261
active single line diagram.
3 New project name when creating a combined project is now applied cor- #19954
rectly.
3 PFD import: In cases when objects in the PFD reference objects that exist #20080
in the target database (but are not shared to the importing user): These DIG28205
references are no longer resolved but are instead reported during the PFD
import.
3 The complete geographical diagram is now shown in cases when no pro- #19995
jection is used. DIG25741
3 The marking and zooming rectangle now remains visible after cancelling #19929
zooming with ESC.
Description ID
3 New single line graphic supports image symbols. #19718
Description ID
3 Using Select all in the output window now behaves correctly. #19782
3 Data Manager: Context menu entries for StationWare functions are now #19619
available for ElmRelay objects.
- The auto-completion feature for DPL scripting has been extended and #19802
now offers suggestions for recently-added, unsaved script variables.
3 The scripting function EchoOff() now additionally disables the update #19992
of the project overview window. DIG25776
3 Row and column label input fields for matrix objects are larger now and #19655
offer the functionality and capacity of the new text editor. DIG26979
3 DZ Snapshots can now be exported via the Data Manager context menu #19891
for active projects.
Description ID
3 The OPC-UA interface now sends values only if a change occurs (if they #20023
are out of the deadband range) in OSE mode.
- The OPC-UA implementation now uses the latest available Unified Au- #19501
tomation SDK (version 1.5.4).
Description ID
3 Fixed a rare compilation issue when creating a library from a DSL model. #19931
3 The DGS export issues now a warning for non-exported references to #19965
external objects. This increases the transparency of the data export pro-
cess.
3 Fixed a problem with the creation of a GPS diagram when the application #19830
is executed in unattended mode without graphical user interface.
Integral:
3 Import: The GPS coordinates have been transferred from the site to #20085
the substation object.
3 Import: The Integral option for AC power angle control (MW/deg) at a #20079
HVDC converter station is now converted to PowerFactory as angle
difference dependent P-droop (for ElmVscmono, ElmVsc) and angle
difference dependent P-droop (for ElmRecmono and ElmRec).
Description ID
3 Export: The selection of relevant zero impedances now considers the #20094
grounding information in the vector group.
3 Export: Lines with a tower type (TypTow) but no line coupling are now #20092
exported correctly. The type parameters are transferred directly to the
Integral line object.
3 Export: The maximum tap of a shunt reactor is now set correctly. #20091
CGMES Converter:
Description ID
3 The Terminal.phases of ABCN and N code types are now converted #20035
correctly.
Description ID
3 Zero line segment lengths are now converted to 1km. An information #20098
message is issued in the output window if either the length is not set,
or is less than or equal to zero. In addition, the converter no longer
overrides the zero length of line segments with 1km when re-linking
to an original CIM source. An information message is issued in the
output window if the length in the original CIM source is not set or less
than or equal to zero.
3 Tap controller indices are now properly considered when multiple tap #20001
changers are present on the same voltage side.
Description ID
3 The scripting object method SetVal now supports integer vectors of #20138
user-defined variables.
3 All DPL functions introduced for fast access of contingency results are #19727
now supported for standard result files (e.g. from simulation).
- Added All Scripts entry to the new Execute Script dialog. #20046
3 The Execute Script dialog no longer creates a new study case script upon #19814
execution (only occurred in specific circumstances). DIG20580
3 The Rd command for opening a text file now works again. #19535
Description ID
3 The Siemens starting element Impedance Z logic now behaves as fol- #19970
lows:
When the Product No. is 510 or 511, the rule which removes
the loops with impedance greater than 150% of the smallest loop
impedance (from the list of the tripped loops), is now only applied to
the earth-fault loops.
When the Product No. is 513, only for the phase-phase loops, the
impedance logic is supplemented by an overcurrent starting logic
where the current threshold is the Iph>> parameter.
3 Timers with an infinite time setting (oo) are now correctly initialised for #19993
RMS and EMT simulation when the timer was already started following
the load flow calculation.
3 Fixed an issue where the Protection Audit and the Coordination Assistant #19928
would sometimes incorrectly disregard protection installation locations.
3 A rounding error which influenced the Load Encroachment block yloop #19949
output signal (during RMS simulation) has been fixed.
3 The Protection Coordination Assistant now correctly selects the smallest #19898
of the possible next paths when calculating zones 2 and 3.
3 Fixed an issue that caused PowerFactory to crash in the following specific #20015
cases: DIG28516
Under-/Overvoltage Type, defined as Overvoltage or Vector Shift
and the reset ratio is >100%; or as Undervoltage and the reset ratio
is <100%;
Instantaneous-Overcurrent Type, with option Negate Output en-
abled and the reset ratio is >100% or a for disabled Negate Output
option and the reset ratio is <100%.
Instantaneous-Overcurrent Type (TypIoc), Time-Overcurrent Type
(TypToc) and Common Time Characteristic Type (TypChar ) with op-
tion Negate Output enabled and the reset ratio is >100% or a for
disabled Negate Output option and the reset ratio is <100%.
Description ID
- Cable Ampacity: The bonding of the sheath, defined as a separate line, #19903
is now correctly considered. DIG28060
Description ID
- Calculation variables for the total losses and total loading are now avail- #19940
able for lines, transformers and series compensation elements.
Description ID
3 Transfer Capacity: The return code resulting from the execution of Com- #19732
Transfer via DPL has been enhanced.
- Transfer Capacity: A DPL function to obtain the feasibility status of the #19734
last iteration has been introduced: IsLastIterationFeasible().
Description ID
3 Results for backbone calculation have been corrected in cases where the #19603
scoring algorithm is used as an objective. Quantities such as loading and
voltage now have improved accuracy in restoration situations.
Description ID
- Optimisation has been enhanced for failures in primary substations when #19807
the check-box Enhanced Restoration is ticked.
- Switches outside feeders are now checked for thermal constraints. #19773
Description ID
3 Stop Simulation message is now printed only once if multiple terminals #20058
are monitored.
Description ID
3 Synchronous machine out-of-service status is now correctly considered #20115
in the simulation scan of the generator speed.
3 Unnecessary event message has been removed when initial condition is #19725
calculated without recalculation of load flow.
Description ID
3 LicenceManager now always starts in server mode when installed with #19961
LicenceComponents.
4.1.20 Documentation
Description ID
- Updates have been made to the following Technical Reference docu- #20144
ments:
PWM converter
Rectifier/inverter
Static generator
WECC SVS model templates
4.1.21 Examples
Description ID
- Transmission System example: The settings for the transient simulation #19672
study case have been improved.
- Wind Farm example: A new study case for short-circuit calculation ac- #18578
cording to IEC 60909-0:2016 has been added. The study cases for UVRT
simulation now have the FRT scan module included.
4.1.22 Miscellaneous
Description ID
3 When left eigenvectors are written to files by Modal Analysis and the QZ- #19710
method or selective method is used, these eigenvectors are now associ-
ated with the generalised eigenproblem and fit to the written matrices M
and Jac.
3 Constant active power generators can now correctly use a characteristic #20143
defined on active power during the DC Quasi-Dynamic Simulation. DIG28230
3 The energising state is now detected correctly in cases when a non- #20192
connected cubicle contains an earthed switch. DIG28795
3 Virtual instruments are now updated after each step. The tabular report is #19953
now also updated when the steps are triggered by the protection toolbar. DIG28540
Switch operations occurring at nearly the same time are now executed
together. An issue has been solved which prevented the command from
starting correctly in certain study case configurations.
Description ID
3 Zero impedance elements are now correctly handled in the DC load flow #19222
calculation. DIG27095
Description ID
3 Short-Circuit Sweep: Fault impedances used for the peak current and DC #19281
current for unbalanced fault types on nodes are now correctly calculated.
3 DC Short-Circuit (IEC 61660 DC): The calculation no longer fails if the DC #18951
system is supplied by a rectifier with the AC side unsupplied or connected DIG27102
to the AC grid via a transformer.
3 An error message has been removed which stated that no valid nodes #19361
for the IEC/VDE short-circuit calculation had been found (despite their DIG27673
existence).
3 Calculation of the kappa factor has been improved for IEC/VDE methods #18906
when connected branches have a negative and/or very small imaginary
part of the impedance.
3 Additional warning messages are now issued via the output window for #19279
the ANSI method if the element impedance is too small.
3 Calculation of the kappa factor for IEC/VDE methods using method B now #18881
always considers compensation multiplier (1.15).
Description ID
3 The breaker tripping time is now correctly updated for multiple-fault anal- #19271
ysis when executed immediately following the Complete method. DIG26519
Description ID
3 Data such as filters and colouring settings is no longer transferred to par- #19524
allel processes. Transferal of the whole project is also avoided. DIG27863
3 DC Contingency Analysis (with time phase): The time constant of phase- #19447
shifting transformers is now correctly considered.
Description ID
Description ID
3 Increased performance for reading ComTrade files (ASCII format) for all #19036
objects accessing them. DIG27050
3 The result file export to .csv now supports real time format. #19364
Description ID
3 Statistic labels in plots now update their label automatically following sim- #19169
ulation.
3 Changed object values in Modification report are now available as click- #19102
able links to objects.
3 The performance of plot refreshing has been improved for plots containing #19359
cursors.
3 The start and end time can be defined in the result file export, exactly as #18912
displayed in the input field.
3 The trigger information visualised in the plots no longer displays the trig- #18911
ger threshold and unit.
- Option Edit data... in the context-sensitive menu of the tabular report may #19089
now be used on a selection of multiple object cells. DIG26536
3 Plots now accept trailing blanks in variable names of ComTrade files. #19139
DIG26154
3 The pop-up result in plots (displayed by curve tracking) now uses the #19136
same time format as the plot. DIG26742
Description ID
- Performance optimisations have been made to the single line graphic; in #18973
particular to GPS diagrams.
- Holding down the Ctrl+Shift keys now allows the simultaneous marking #11256
of annotation objects and network elements.
3 Polygon buses at the edge of a single line diagram are now drawn even #18837
when only partially visible.
Description ID
- Asynchronous machine configured as a DFIG supports now the local con- #19133
trol mode const. cosphi.
3 The active power in the DC load flow now uses the correct sign for PWM #19145
converters which are not P-controlled. In addition, DC loads and DC cur- DIG27452
rent sources are taken into account. DIG27095
3 The Frequency Analysis tool (ComFrequency) now accepts plots with #19156
scale units other than seconds (ms, minutes...).
3 QDSL element dialog now handles cases where no type is selected. #19311
3 Step-voltage regulator (ElmVoltreg): Load flow now handles the parallel #18859
connection of two or more step-voltage regulators with a neutral connec-
tion at the terminals.
Description ID
3 Transformer controlling a remote node: Initialisation of RMS simulation is #19319
now handled correctly.
3 Towers are now handled correctly when connection request elements #19362
(ElmConreq) exist in the network.
3 The status of PWM converters will be started from the base case in Con- #19466
tingency Analysis or from the previous case in Quasi-Dynamic Simulation,
regarding power limits.
- Static var system models SVSMO1 and SVSMO2 according to WECC #19373
have been added as Templates to the library.
3 Variable speed drive (VSD) template: Issue regarding initial condition for #19520
simulation (with open motor breaker) has been resolved.
Description ID
3 Identical line widths are now shown for both dashed and solid lines. #19195
3 Running Arrangements are now applied correctly when the active Sce- #18949
nario is changed by a scheduler due to a study time modification.
Description ID
3 Inserting/defining a template: #18942
Assigned frequency and time characteristics are now stored
(packed) in the template folder library;
Cancelling while inserting a template and a Variation is active is now
handled correctly.
3 The Compare & Merge Tool now properly handles the case where an Int- #19160
Fltcases object outside a project folder is contained in one of the projects DIG27435
to be compared.
3 When exporting the entire diagram as a bitmap, only the drawing area is #19020
shown. DIG22168
3 The migration has been corrected for the synchronous machine type (to #18981
version 15.1) when exporting a .pfd to a former version. DIG27173
3 Legacy annotation objects storing several geometrical objects in one Int- #19090
Grf (created via DPL script) are now shown again.
3 Bay-end result box for detailed substations now additionally shows the #18828
relays and CTs located inside the bay.
3 Upon deletion of a project version along with its derived projects, the Data #19013
Manager is now updated correctly.
- The attributes indicating parallel installed equipment are now able to be #18997
recorded by Scenarios for the following components (to be selected via
the Scenario Configuration): ElmTr2, ElmTrb, ElmTr3, ElmTr4, ElmVsc,
ElmLne, ElmVscmono.
3 Migration of 3-winding transformers: Export now correct for data (pfd) to #19100
former PowerFactory version (2017 to 2016). DIG27307
Description ID
3 Layer images are now visible in exported SVG files. #17430
DIG24905
- Additional recurrences (Yearly, Monthly) are now available for file-based #19303
ChaTime.
3 Plots and block diagrams can now be exported without a frame. #19295
DIG15406
3 Improved area colouring for substations without busbars, and for substa- #19004
tions containing nodes grouped in folders. DIG25759
3 Switch User menu entry is now disabled if there are no other users in the #19015
database.
Description ID
3 User-defined toolbar buttons are now available for tabular reports #19218
(ComTablereport). DIG25933
3 Project activation is now possible by right-clicking the link in the output #19098
window.
3 Icons for user-defined tools are now correctly displayed in the main tool- #19333
bar.
3 Clicking the line/column field in the text editor status bar now opens the #19266
Go-to-line dialog.
3 Right-mouse button menu in the Data Manager or in the Network Model #19345
Manager: Significant performance improvements when a large number of
elements is selected.
3 The title text of element dialogs is no longer curtailed under Windows 10. #19197
Description ID
3 The ComWr dialog now remains functional after storing the content of the #19317
output window to a text file.
3 IntOutage: Dialog is now closed after any of the buttons Apply, ApplyAll, #18918
Reset or ResetAll are pressed.
- Updated localisation for the following languages: French, Spanish, Chi- #18935
nese and Turkish.
- A new right-mouse button sub-menu Go to allows setting the cursor to the #19083
previous or next message of a certain type:
The cursor stays in place (at the same or next displayed message)
when the message type filters change;
Links to non-database objects are now handled correctly (and are
no longer clickable).
3 During application startup, the dialogs for Database Migration, Wrong #19158
User Password, etc, now have a window title.
3 The Project Overview window now displays a query box if an entry is to #19121
be deleted and the user setting Confirm delete activity is enabled.
- New hotkeys for clearing the output window are available: #19087
del: Clear output window with user prompt;
ctrl + del: Clear output window without user prompt.
3 Contingency Analysis report: The ASCII report for the worst loading vio- #18814
lations now has correctly formatted output for the German language local-
isation.
Description ID
3 The ComLink Execute function now returns the correct value if executed #19075
via DPL, Python or API.
Description ID
- The detection of nominal voltage level for nodes has been improved, al- #18947
lowing topological traversal not only to pass switches but also lines located
inside primary substations.
- The OPC-Deadband value is now used for variables which have been #19162
read and written.
3 The Discovery button and Certificate textboxes are now wider in order to #18593
accommodate the German text.
3 DGS 5.0: Now supports logging of all moved objects if the fold id #18908
changes.
CGMES Converter:
Description ID
3 CIM-to-Grid converter: The Converter sets now the phase technology #19293
(ABC-N) for the corresponding connected nodes (ElmTerm) correctly
for 3-w/2-w transformers having ABC-N neutral connections.
Description ID
3 Grid-to-CIM: Converter now exports Model.scenarioTime in UTC #19273
format according to the official ENTSO-E document: QUAL-
ITY OF CGMES DATASETS AND CALCULATIONS 1st edition. In
addition, CGMES CIM-to-Grid now imports Model.secnarioTime pro-
vided in UTC format.
3 Grid-to-CIM: #18850
Out-of-service flag on external controllers is now taken into account;
The voltageSetPoint of the StaticVarCompensator is now set to the
target value if the target is a remote node.
CIM-to-Grid: Auto-generated PowerFactory elements with no CIM
source (e.g. power-frequency controller) no longer use CIM RDF IDs
as the name and the ID is no longer set in the CIM RDF ID Mapping
table.
3 Grid-to-CIM: #19044
A PetersenCoil is no longer created if the actual step of the RL shunt
is set to zero (open circuit).
Detailed description for EQ, TP, SSH options are now included in
the Grid-to-CIM and CIM-to-Grid converter dialog;
CIM Data Import(ComCimdbimp): Database is now synchronised
before starting the CIM data validation;
- The CIM Data Validator now reports unknown properties and classes #19104
as warnings instead of errors.
- The CIM Data Validator now reports only the number of errors to the #19106
output window (i.e. those found during CIM Data Import and Export),
instead of the full list of errors.
Description ID
Integral:
3 Import: Consecutive Integral XML imports are now correctly handled. #19497
DIG27442
- The Integral export has been further improved with regard to the sub- #19350
station topology and its graphical representation. Information is gath-
ered from both PowerFactory diagrams and electrical connectivity.
The logging of model setups that would lead to contradictory repre-
sentations in Integral has been improved.
Description ID
Description ID
3 Backslashes are no longer allowed in name filter of #19051
GetCalcRelevantObjects(). DIG19662
- Introduced the following to adjust the automatic reset of the calculation #18893
when setting attributes in API/DPL/Python: DIG25853
IsAutomaticCalculationResetEnabled()
SetAutomaticCalculationResetEnabled()
- Added a method Save() to matrices (IntMat) and vectors (IntVec) which #19363
stores changes made to the database; e.g. setting a matrix entry with DIG26979
IntMat.Set().
3 The extension libraries digdplfun, digexfun and digexdyn can now be #18830
loaded from the working directory.
string SetTboxconfig.GetAvailableButtons()
string SetTboxconfig.GetDisplayedButtons()
int SetTboxconfig.SetDisplayedButtons(string buttonIds)
int SetTboxconfig.Check()
int SetTboxconfig.Purge()
Description ID
DPL:
3 Reading virtual attributes of type multi-line string (e.g. the selected #18879
variables cComvars of a Variable Selection (IntMon)) is now handled
correctly.
Python:
3 Setting the variable in an X-Y plot (VisPlotxy ) now assigns the correct #19177
variable.
- Performance improvement in cases when the user break button is en- #19010
abled. DIG19491
DIG19031
Description ID
3 The simulation now properly handles the directional relay unit. #19489
DIG27641
- The primary and secondary tap settings of a CT and VT are now updated #18834
when a corresponding type is selected. The first defined value from the DIG26075
table in the type is used.
Description ID
- The Short-Circuit Trace command has been enhanced as follows: #19358
Inverse-time characteristics now consider time spent in previous
steps to achieve a better approximation of the tripping time;
Improved behaviour in cases where the function responsible for the
trip changes between steps (e.g. from IDMT to DT units);
Replaced output window messages with a comprehensive tabular
report;
Option to block breaker operation during the trace;
- Time-distance plot: Representation of the result has been improved for #18916
the short-circuit method. The trip curve is displayed on the forward plot
when the corresponding short-circuit location is topological (along the
path) in the forward direction, and vice versa.
3 Fixed an issue with the verification of device coordination. The Protection #19085
Audit no longer verifies and displays additional, invalid coordination pairs.
3 The time-distance plot now correctly draws relays in cases where the cur- #18822
rent transformer is defined in the direction of the busbar.
3 The size of the time-distance plot now considers the option Hide names #18903
of busbars without relays.
3 In the Distance Polygonal type dialog, the R1, -R2, -R3, and R4 inputs #19202
are now hidden when the polygonal type is not CHEAR Quadrilateral(Z).
Description ID
- The Short-Circuit Trace calculation has been improved (for details please Relates
see #19358). This affects calculations performed with relay tripping times to:
determined by Iteration. The large majority of cases will see no difference #19358
in determined tripping times, as the incident is cleared by one device only.
For cases where multiple relays are required to operate to clear an in-
cident, times may differ from calculations performed in earlier versions.
Most cases will result in shorter clearing times due to the better approxi-
mation of IDMT characteristics. For special clearing sequences, a slightly
increased time might be observed.
3 Fixed an issue that caused the arcing time to be incorrectly determined #19225
under certain circumstances. DIG27384
Description ID
3 Cable Reinforcement: The warning messages for line sections with #18833
changed line types are correctly printed in the output window.
3 Cable Ampacity: The correct phase number is now applied when calcu- #19327
lating the maximum current for the IEC method. DIG27286
Description ID
3 Loads with negative active powers are now ignored in the scaling of #18882
loads analysis. DIG26296
Description ID
3 Negative loads are now considered as generators and are not counted as #18998
interrupted loads.
Description ID
3 DC OPF: The ASCII reports for worst loading violations, all loading vi- #18871
olations and loading violations per case are now correctly issued. The
correct result file is now used.
3 Functionality of extended station controllers and tap controllers has been #19370
improved for OPF and State Estimation.
Description ID
Description ID
3 Connection points on block slots and block references which are no longer #18993
used are now removed as follows: (i) following Rebuild; and (ii) if input or
output variables were deleted when elements were edited via the graphic.
Description ID
Description ID
3 The Upgrade Assistant now warns regarding a workspace which already #19014
contains data.
- CodeMeter runtime has been updated to the latest version (6.40a). #19131
Description ID
LicenceManager:
5.1.22 Documentation
Description ID
- New Technical Reference document available: Result variables for the #19389
EMT simulation.
3 Equations have been corrected for the susceptance, B, in the documen- #19397
tation for the 9-Bus System example and for the 14-Bus System example.
- The documentation for the 39-Bus System example now has updated #19403
icons and screenshots which show the PowerFactory 2017 GUI.
Description ID
- New Technical Reference documents are available for: #19388
Booster Transformer
WECC SVS model templates
Updates have been made to the following Technical Reference docu-
ments:
2-Winding Transformer
3-Winding Transformer
Directional Block (Protection Devices)
General Load
PWM Converter
- Whats New in PowerFactory 2017: Updated English and German ver- #19385
sions.
- A guide for the handling of the new OPC-UA interface is now available. #19330
5.1.23 Examples
Description ID
- Wind Farm example: Eddy current losses are now considered in trans- #19186
former types in the harmonic load flow and frequency sweep calculations.
Busbar type data has been revised.
- Industrial Network example: Eddy current losses are now considered in #19287
transformer types in the harmonic load flow and frequency sweep calcu-
lations. The 10kV busbars now use busbar types from the global library.
5.1.24 Miscellaneous
Description ID
3 Boundary object: Optional reporting of open switches that comprise the #19034
boundary (which splits the network). This option is available via a button DIG24126
in the boundary dialog.
3 Parallel calculation now works following network disconnection (e.g. from #19135
WLAN).
3 Neutral connections are now properly considered for calculation when au- #19325
tomatic out-of service detection is enabled and the neutral area is not
grounded via a grounding switch.
- PFM Master Station file synchronisation now uses the sync. service to #19357
collect the ComTrade files.
3 The class name in the variable selection (IntMon) is no longer case sen- #19163
sitive.
3 The context-sensitive menu entry Check is now displayed for the planned #19072
outage. DIG27238
- Contingency Analysis and Optimal Power Flow now issue an error mes- #19262
sage and stop the calculation if the result file can not be written to disk.
- Navigation through PFM default plots is now available starting from trigger #19023
info VI.
3 Files created in the temporary directory during the Quasi-Dynamic Simu- #18909
lation are now removed automatically by the calculation.
Description ID
- Mark affected components is now additionally available for planned out- #18914
ages which have already been applied.
3 Static generator (ElmGenstat): The conflict between the station controller #19216
(when not in voltage control) and local machine Voltage-Q Droop mode DIG26306
has been resolved.
3 Two-level PWM converter (ElmVsc): Input signals u a, u b, u c for the de- #19380
tailed EMT model now work as described in the Technical Reference. Ad-
ditionally, three new inputs have been added (urefA, urefB, urefC) which
allow control of the detailed EMT model with reference phase voltages.
6 PowerFactory 2017
6.1 Features
PowerFactory 2017 introduces several major features, as listed below and described in the
PowerFactory Whats New document. Key highlights include:
Enhanced Diagram Layout Tool for auto-drawing of feeders and branches, protection de-
vice layout, as well as auto-layout of site and substation diagrams
Output window redesigned to be interactive, with flexible filter functionality
Add-on Modules: new framework for user-extendible function scope including fully inte-
grated result representation
New Project Combination and Connection Assistant
Various new and enhanced power equipment models (harmonic filters, busbar trunking
systems, voltage regulator, 4-winding transformer, and power frequency control using
merit order)
New QDSL modelling language: User-definable load flow and quasi-dynamic simulation
models
Unbalanced Feeder Load Scaling
New optimisation methods for Tie Open Point and Phase Balance Optimisation: genetic
algorithms and simulated annealing
Extension of failure models and power restoration strategies for Reliability Analysis
New Outage Planning module
Power-frequency controller (ElmSecctrl): A new active power distribution method has been im-
plemented (According to Merit Order ) which allocates the slack power taking into consideration
the merit order and the limits of the generators. (#16907)
Automatic tap change for phase shifting transformers is now supported in DC load flow. (#17392)
2-, 3- and 4-winding transformers (ElmTr2, ElmTr3, ElmTr4): The current compounding compen-
sation is a new tap controlling method which controls the transformer voltage within acceptable
limits, by increasing the voltage setpoint as the load current or power increases. (#17640)
A new QDSL model has been developed which enables the user to define controllers using a
simple, DPL-like language. It is a user-defined model that is integrated into the load flow algo-
rithm. In addition to the pure static load flow control, these models also feature time-dependent
state variables which can be used to govern the dynamic behaviour of the Quasi-Dynamic Sim-
ulation. More details are available in the Whats New document. (#16395)
Network Reduction based on the REI equivalent now supports a short-circuit equivalent (bal-
anced and unbalanced) (#17448)
Tie open points can now be displayed in the single line graphic. (#17088)
The layout of relays, CTs and VTs can now be performed automatically. (#13583) (#18212)
The representation of branch elements other than lines is now possible in geographic diagrams.
(#15831)
DGS version 6.0 has been introduced which supports consistent usage of foreign keys and
offers features for working with data from various sources such as multiple grids. (#15417)
The OPC interface has been significantly enhanced and now supports OPC Unified Architec-
ture. (#16505)
Support of the Siemens 7SA8 adaptive loop selection for the Siemens starting unit. (#18019)
Support of RMD (Reactance Method Distance) for Siemens 7SA8 relay models. (#17781)
The Distribution option is now available for weakly-meshed networks. More details are available
in the Whats New document. (#14989)
6.2.10 Miscellaneous
A new export format has been introduced. The snapshot format allows the export of a project
state as it is in memory, without the overhead of comprehensive model details. (#17367)
A new power transfer event (EvtTransfer ) is now available in contingency analysis, RMS sim-
ulation and is also supported in outage planning. This event can transfer power from one load
or static generator to other loads or static generators. (#18088)
6.3 Improvements
Description ID
3 The message Load flow calculation not executed is now shown as an #16919
error.
- Active/reactive power limits can now be considered per model type. In #16837
addition, the design of the Load Flow command has been re-organised.
More details are available in the Whats New document.
3 The load flow setting Ignore composite elements no longer ignores pro- #16455
tection devices.
- The following new calculation quantities are supported for the boundary: #17549
ImportP, ImportQ (imported active and reactive power)
3 DC load flow with secondary controllers now correctly handles genera- #16666
tor limits in cases where multiple generators are connected to the same
calculation bus.
3 Shunt/filter (ElmShnt): In the balanced load flow calculation, the capacitor #16942
current is now correctly set to zero for an RL shunt.
3 Rectifier: The load flow now converges if the rectifier is not supplied from #17903
AC side (the DC network is now correctly treated as being unsupplied).
- Feeder Load Scaling during the Load Flow has been enhanced to sup- #16692
port phase-wise scaling of loads inside feeders in order to meet given
setpoints. More details are available in the Whats New document.
Description ID
3 2-winding transformer: Calculation of loading has been improved for #18322
single-phase transformers. DIG26549
- 3-winding transformer: Support of second tap controller in load flow and #18328
RMS simulation.
3 In order to improve load flow convergence, initial scales for Feeder Load #17160
Scaling are now calculated more precisely.
Description ID
- An additional option has been introduced to skip the transient calculation. #16135
More details are available in the Whats New document.
- Short-circuit sweep has been enhanced in terms of performance for var- #17565
ious fault types calculated at single or multiple fault locations, such as
nodes, branches or line elements. More details are available in the Whats
New document.
3 Out-of-service switches are now handled correctly in the analysis of mul- #18082
tiple faults. DIG26166
3 The input field Step only over lines < has been renamed to Maximum #17032
search distance over lines <. DIG24250
Description ID
- It is now possible to disable node reduction for the optimised method. #17671
- The contingency analysis for a specific region now also supports: #15619
areas and zones; and
boundaries
extended by a k-neighbourhood.
- A new method has been introduced to calculate transformer tap sensitiv- #17730
ities/effectiveness using discrete assessment by varying taps up and/or DIG18881
down. More details are available in the Whats New document. DIG4989
- Execution of a single contingency via the context menu is now available. #17006
More details are available in the Whats New document.
Description ID
- Parallel quasi-dynamic simulation now occupies less memory when only #18458
a small number of packages must be calculated.
Description ID
3 The network reduction issue which occurred using a distributed slack (as #18399
of PF2016) has been corrected to that in PowerFactory 15.2. DIG26695
Description ID
Description ID
- A version field has been added to the Tabular Reports command that can #16431
be used to track changes and updates.
3 The status bar of the y2 plot now displays the positions of y1 and y2. #17882
- Output messages have been introduced to the Result Export command #18107
to simplify its usage.
3 Duplicate or missing time stamps no longer occur when exporting data #18173
from ComTrade or result files, provided that the step size is appropriate.
3 The result file export now considers the time range of plots which are #18174
exported.
- The result file export now considers the sign of very large values (#INF #14662
and -#INF).
- Plots: The name True Dots has been changed to Raw Data. #14652
Description ID
3 The drawing speed for displaying a large number of trigger events in plots #17769
has been greatly improved.
- The icon to create plots for the Quasi-Dynamic Simulation now by default #18534
creates plots using the x-axis defined by the Graphics Board.
- Two different cursors are now available for the plots. These cursors are #18536
linked to the x-axis being used, meaning that several plots may use the
same cursor. Cursors are enabled/disabled using two additional icons
inside the plots toolbar.
Description ID
- Equipment types for busbar trunking systems have been added to the #18057
library.
- New ENTSO-E dynamic models have been included in the library: #18338
Exc REXS
Exc SK
Oel OEL2
Oel X1
Oel X2
Uel IEEE1
Uel IEEE2
- The parameter event option Recompute Dependent Parameter has been #15669
removed.
Description ID
- Synchronous machine: An option for precise conversion between the #15664
open-loop and short-circuit time constants has been added to the stan-
dard synchronous machine type when using short-circuit input data.
- An external grid (ElmXnet) can now be selected within a station controller. #18454
3 The modal parameter calculation used for lines and cables has been im- #15514
proved in terms of numerical stability. Previously, in cases of exact sym-
metry of the impedance matrix, the instability was evident in calculations
such as the frequency sweep. In such cases waveforms appeared as
highly oscillatory and non-smooth.
3 The load flow calculation no longer fails when an SVS controls a busbar #18451
which is isolated. DIG26570
- Performance improvements for load flow and simulation when the projects #17631
contains many grouping elements e.g. zones, areas or grids.
3 Lines defined with tower types no longer cause a matrix inversion error in #11435
unbalanced calculations when Z0 is zero; but instead assume that Z0=Z1. DIG11790
3 PWM converter (ElmVsc and ElmVscmono): In the load flow calculation, #18378
reactive power limits are now correctly considered when the AC voltage is DIG26698
remotely controlled.
Description ID
- Complex load: In cases where the voltage drops to a low value, diver- #16596
gence of the RMS simulation is now avoided by the use of voltage limits.
Outside the voltage limit, the power may be modified. Further details are
provided in the Technical Reference.
- New option available for various branch elements to assign the losses for #17652
the load flow calculation to:
PowerFactory default (according to grouping element);
- Shunt/filter: The voltages (e.g. across capacitor, inductor, etc) are now #5842
available in kV.
3 ENTSO-E Dynamic Model Exc IEEE ST5B: The parameter Tr has #18575
been removed from the model because it is part of voltage measure- DIG26222
ment/compensator models (Vcmp within the ENTSO-E Dynamic Models).
3 The generator scaling factor is now properly considered for the 1-ph and #18250
2-ph MV load models.
3 Static generator: The voltage source model can now be initialised for an #17126
RMS simulation when the impedance is set to zero and the A-stable algo- DIG24133
rithm is not used.
Description ID
3 When text boxes are modified via the Layers icon Change Font, the #13883
changed colour is now considered. DIG17563
Description ID
- New DPL function available for setting the visibility of element layers. #14009
DIG18019
3 The line symbol (short dash) is no longer shown in geographical diagrams #18308
if connected nodes are not displayed. DIG26251
3 PowerFactory now shuts down correctly following the Administrator dele- #18351
tion of whole users when the purging option is selected.
- Colouring mode Voltages/Loading: Line end boxes are coloured accord- #17002
ing to the loading of the related switch/es.
- The size of partial LV-load circles in geographical diagrams has been #14598
adapted.
3 When setting the starting node in a diagram, the list of drawable elements #16422
is now updated in the Draw Existing Network Elements browser. DIG23056
3 Fixed occasional crash when defining templates with a large number of #16439
objects. DIG23127
3 The Scenario Scheduler is now correctly updated when its configuration #14858
(start/end time) is modified via the dialog.
- The Estimated size field of the Project dialog (IntPrj) has been removed. #17825
3 The DZ export/import of objects containing the pipe character | in any text #18232
attribute is now handled correctly.
3 In specific cases, i.e. when a substation is hidden but its contents not, the #15989
contents are no longer considered by the load flow calculation. DIG22219
Description ID
- The following attributes of the AC voltage source can now be recorded by #18182
Scenarios: Pload, Qload, Pgen, Qgen, Pzload, Qzload, Kpf, Ksf.
3 When showing a GPS diagram, a Diagrams folder is now created if it does #15088
not yet exist. DIG20779
- Automatic substation layout improvement: Connection lines are now dis- #15095
played for all elements which are connected to terminals in bays. DIG20870
3 The colour legend is now always displayed when using the DPL WMF #17468
export function GraphicsBoard.WriteWMF(). DIG24955
3 DPL AddCopy no longer creates a deep copy of derived projects which #17782
appear as master projects. DIG23541
3 Layer visibility modifications are no longer retained if Cancel was pressed. #16044
DIG22422
3 Non-standard TCP ports for WMTS and WMS map service protocols are #18055
now supported. Correct axes-order for EPSG:4326 and EPSG:4269 map
projections are now used in WMS 1.3.0.
- Multiple WMS map layers can now be displayed simultaneously in the #18077
background of a single line graphic.
3 Text box modifications from the layers configuration is now persistent (i.e. #18098
maintained).
3 Mark in Graphic now works on diagrams with an inactive Target pointer. #18114
- Additional bitmap formats for graphics export are now supported: GIF, #18153
TIFF, JPEG. The output resolution can be specified (DPI).
Description ID
- Dialog: #17509
Read-only input fields, i.e. for the name or for the input, output sig-
nals of a block definition are now click-able and the contents can be
copied.
For objects added to the base case: the name and foreign key can
now be copied.
- Moved main toolbox button Load Flow Sensitivities from Additional Tools #18315
to the right of the Load Flow button.
3 The Python (ComPython) dialog is now only closed if the script path is #18383
valid and the chosen Python editor is the internal editor.
3 Input field for PowerFactory path of the Remote Machine Configuration #16677
(IntMachine) has been extended to handle long paths.
3 DPL: F1 now works correctly when code is viewed in the text editor. #17469
3 General Filter: Now works correctly when object filter wildcards are used: #16117
i.e. Lne.ElmLne and the option Relevant Object for Calculation is en-
abled.
3 Data Manager: The asterisk (*) is now displayed upon modification of a #18169
parameter.
3 Find previous in the output window now works correctly if the currently- #13077
marked word starts at the beginning of a line.
3 The language names in the configuration (SetConfig) dialog are now only #16328
displayed using English language identifiers.
3 The SetTime dialog now uses the 24-hour time format in the Russian #15947
locale, allowing the user to set the Hour of Year. DIG20731
Description ID
- Text editors for scripts and DSL macros have been replaced. #17506
3 Line sections of lines which are set Out of service are no longer listed in #16464
the Network Model Manager.
3 The number of active system stages displayed in the Project Overview #17968
window is now correct.
3 Import dialogs are now displayed if the last used path value contains the #18072
value . or \.. DIG26176
3 DPL function MarkInGraphics() now marks elements which are part #14016
of a drawn substation or branch. DIG18068
3 Improved messages for the database update (switching to a new service #18316
pack) and database migration (switching to a new main version) have DIG26532
been introduced.
3 Leaving the Data Manager window while editing a cell value now behaves #16206
as expected.
3 Description and unit texts are now kept associated with the correct pa- #18307
rameter in the DPL (ComDpl) input parameter table following the removal
of a preceding row.
Description ID
3 Upon UCTE export, the voltage (kV) of an auto-assigned slack was not #16612
correctly exported when the roundtrip option was set to false. The auto-
assigned slack indicator struct = -3 in such cases comes from a PSS/E
export. This has been corrected. Active and reactive power generation
are now properly exported for this slack.
3 CIM ENTSO-E 2009 Export: A station controller (ElmStactrl) using Volt- #18014
age control with Maximise Reactive Reserve on the HV side now exports
the regulated target properly when the user has selected a busbar on the
HV side.
DGS:
- DGS 6.0 supports the new operator M(erge): If the specified element #15379
does not exist then it will be created. Otherwise the specified element
will be updated.
3 Fixed an issue involving the import of DGS files containing special #15864
classes such as TriVal and ChaScalar, which are now placed either in
the Operational Library or directly as a child of the element Elm.
3 Import: Start and end times can now be set via DGS for a Scenario #15848
Scheduler.
3 Export and import now support writing and reading of Microsoft Office #16841
Access 2007 files (.accdb).
3 Under specific circumstances graphical data imported via DGS was #17493
not stored to the database, resulting in lost data after restarting Pow- DIG25085
erFactory . This problem was caused by a write cache optimisation
which has been fixed.
Description ID
Integral:
3 Import: For transformers contained within Integral source files, whose #18273
primary side is not the high voltage winding, the copper losses Pcu
and the vector group phase shift are now correctly calculated.
3 Import of wind generating units has been extended by the Integral At- #18272
tribute flag wea art. The short-circuit power is now calculated from the
nominal active power and the short-circuit current.
3 For transformers whose primary side does not correspond to the high- #18155
voltage winding in Integral, the calculation of the rotation angle has
been improved upon Integral graphics import.
CGMES Converter:
Description ID
3 CIM-to-Grid: Converter now sets the terminal (ElmTerm) Usage to #18467
Busbar for CIM ConnectivityNodes with junction connectors.
3 CIM-to-Grid: The PowerFactory study time is now set to the latest #16036
scenerioTime of the selected Cim-Model.
3 CIM-to-Grid: #18159
The CIM PowerTransformer.beforeShortCircuitAnglePf is now prop-
erly converted to ElmTr2::cosphib lv parameter.
Description ID
3 Grid-to-CIM: Elements connected between the same TopologicalNode #18474
are now ignored for conversion. A warning message is issued. DIG26447
Description ID
3 After encrypting ComDpl or BlkDef objects, all existing historic copies are #16500
now deleted from the database.
3 Solved issue of incomplete ASCII Result Export (ComRes) when adding #17441
new variables via the scripting interface. DIG24921
3 Manual creation (e.g. Data Manager, DPL, ...) of a switch (StaSwitch) #13910
inside a cubicle (StaCubic) is now enabled when possible. DIG17676
DIG21537
3 The New version available dialog is no longer displayed upon activation #16208
of a derived project via API. The derived project will not be updated to the DIG22698
new version in this case.
Description ID
3 Re-established handling of dots in object names for the following scripting #14654
functions: DIG19708
DIG26165
ActivateProject()
GetFromStudyCase()
GetCalcRelevantObjects()
object.GetChildren()
object.GetContents()
object.GetReferences()
object.SearchObject()
set.FirstFilt()
- The Execute Script dialog has been redesigned to provide a better #14860
overview of available scripts.
- DPL/Python: Status messages contain now a symbolic link to the script. #17404
DPL:
Description ID
3 The Harmonic Contingency Analysis DPL script is no longer depen- #18053
dent on the regional settings configured in Windows. DIG25348
3 Checking a script which uses the general selection (SEL) can now be #15245
performed in the absence of a General Selection.
Description ID
- The fuse model has been extended to support a neutral wire and the #13096
option interrupts neutral wire. DIG15745
3 The directional element now trips correctly for a forward fault during the #17929
EMT simulation. DIG25718
3 Protection unit ranges with one value and an infinite key; e.g. 10;oo or #18146
7;oo, are now correctly handled. DIG26237
Description ID
3 An error message has been added to the following relay model block when #17116
set in the connection scheme without the clock signal connected:
ABB directional (RelDisdir class)
Siemens directional (RelDisdir class)
3 The Output of Coordination Results command now correctly sets the zone #16074
timers to the values specified in the Protection Coordination Assistant
when writing the results back to the devices.
3 The routine which checks if the position of the system impedance is inside #16428
the Quad (Beta) polygonal type now works correctly. DIG22581
3 The phase preference for Ph-Ph-Earth faults is now visible for Siemens #18017
7SA511 starting units set to Underimpendance U/I starting.
- Two protective device polarising methods can now be combined with a #17700
multiplier applied to the voltage values calculated by the 2nd logic.
3 Siemens starting unit variants now detect the fault loop correctly during #18523
dynamic calculations.
3 Initialisation of the ystart and ysall output signals of the Siemens starting #18370
unit has been corrected.
Description ID
3 Static VAr Compensator: The default value for the maximum harmonic #17072
order of an ideal SVS has been changed from 31 to 50.
Description ID
3 2-Winding single-phase transformer (ElmTr2): Tap-dependent #17575
impedance:
The leakage impedance is now correctly considered in the harmon-
ics calculation.
- Harmonic Load Flow: New calculation variables are available, including #17454
harmonic losses and loading at each harmonic order.
3 Harmonic Load Flow and Frequency Sweep: Correct handling of trans- #13430
formers is now applied in cases where the grid nominal frequency differs DIG16228
to the Nominal Frequency defined in the command. DIG16477
DIG25257
Description ID
Description ID
Description ID
- New optimisation methods have been introduced: #15578
Simulated Annealing
Genetic Algorithms
More details are available in the Whats New document.
- Additional results related to costs are now written to the result file. #16332
- Output of the objective function value during the optimisation process #16348
is now supported.
Description ID
- The subpage FEA has been separated into two subpages: Protection and #17695
Restoration.
- The creation of contingencies has been prevented for combinations of the #18140
following faults:
Double-earth faults
Independent second failures
Protection failure
- Backward Recovery for substations is now possible. More details are #16417
available in the Whats New document.
Description ID
- It is now possible to replace melted fuses during restoration. #17693
3 The report recovery scheme now displays generator and load-shedding #13051
events. New scripting functions are available to retrieve restoration infor-
mation for a contingency from the reliability result file.
3 Various improvements made for pure neutral wire connections or areas: #12020
In reliability they are no longer used to re-supply;
Isolate, Energise are no longer supported;
- Simplified modelling of protection devices for Reliability has been intro- #16202
duced.
Description ID
- The performance of the DC Optimal Power Flow has been drastically im- #17270
proved. In addition, the memory usage during the calculation has been DIG24540
reduced.
3 Initialisation for optimisation algorithms has been enhanced. This leads #16704
to faster convergence of the non-linear optimisation part of the State Esti-
mation and the AC Optimal Power Flow.
3 The memory usage to calculate a DC Optimal Power Flow has been re- #18445
duced. DIG26649
Description ID
- More robust algorithm to solve network equations during dynamic simula- #18360
tion.
Description ID
- File paths can now contain place holders for the following base directories: #17488
Installation directory: $(InstallationDir)
Workspace director: $(WorkspaceDir)
External data directory: $(ExtDataDir)
3 User-defined events occurring at the same time instant are now ordered #10658
deterministically.
- Additional simulation scan module: Fault Ride-Through. More details are #9078
available in the Whats New document.
3 Static VAr System (ElmSvs) with detailed TCR model: Improved internal #18016
frequency measurement in EMT simulation. Previously in some cases
high frequency spikes could result in wrong currents of the thyristor-
controlled reactor; especially during the first cycles.
Description ID
3 Shunt (ElmShnt): Neutral current derivative is now correctly considered #18192
in the case of a two-phase shunt with external neutral connected to a bus
with different nominal voltage.
3 2-phase loads: The EMT simulation now correctly handles loads config- #17399
ured to be Mixed inductive/capacitive.
3 Complex load: The angle phiref in the EMT simulation is now limited from #11938
-PI to +PI.
3 New AVR model avr ST6B IEEE according to the IEEE 421.5 specifica- #14242
tion of PI controllers has been added to the Standard Models library. DIG18345
3 The tap position of a SWER transformer can now be changed in the RMS #8722
simulation via a tap-event. DIG4877
3 Transistor currents (Ip A/B/C and Im A/B/C) are now available for the #15451
variable selection (EMT simulation).
3 Blocking of the PWM converter now works properly during RMS simu- #15456
lations when short-circuits on the AC side are applied.
Description ID
3 The option Reinitialise equations after event is now neglected in the #14941
calculation of initial conditions of systems with DC models.
3 The option Reinitialise equations after event is available for calculation #14940
of initial conditions of systems with A-stable models.
3 The option Reinitialise equations after event for the calculation of initial #14912
conditions in an RMS simulation recalculates algebraic variables and
state derivatives at interruption. Otherwise all system variables and
derivatives are linearly interpolated.
- The simulation time is now displayed in the status bar following calcu- #13551
lation of initial conditions.
3 Additional setting introduced which allows the user to select whether #17716
the random number generator should be updated or not in the calcu- DIG25444
lation of initial conditions, and in Generation Adequacy Analysis.
Description ID
3 Parameter events and outage events are dealt with in the simulation #10373
according to the selected Simulation behaviour at user-defined events
option in the calculation of initial conditions.
DSL:
- New DSL function rms() returns 1 for an RMS simulation and 0 for #17596
an EMT simulation. New DSL function balanced() returns 1 for a
balanced simulation and 0 for an unbalanced simulation. More details
are available in the Whats New document.
3 Limits of limited state variables in DSL function limstate must not #15343
depend on the limited state variable.
Description ID
- New const variants (i.e. lim const, limstate const, #15266
picdro const, select const and selfix const) of DSL func-
tions are provided to offer better performance when the second and
third arguments of a DSL function include only constants, parameters
and selector functions. More details are available in the Whats New
document.
Description ID
3 Modal Analysis: Removed results for invalid state variables of loads and #18491
generators reported for eigenvalues.
3 Eigenvalues obtained by Modal Analysis are now correct for cases when #18507
HVDC links are contained in the grid.
3 Simulation result file is now written correctly when Modal Analysis is exe- #18543
cuted.
3 If a Modal Analysis is executed during an RMS simulation, i.e. when the #17289
simulation has stopped after a certain simulation time, the simulation can
be successfully continued afterwards.
3 RMS simulation results are now available following execution of Modal #17111
Analysis and the simulation is not re-initialised.
3 Modal Analysis can now be executed without a prior call of initial condi- #15789
tions or load flow. If state variables are not initialised, this is now per-
formed automatically.
Description ID
- Upon licence activation the USB dongle firmware is now updated to ver- #18541
sion 3.11 if necessary.
- Added new features to Scripting and Protection modules. Two new mod- #18097
ules are now available: Outage Planning and Integral Export.
3 The Licence Components setup now allows the omission of individual fea- #17004
tures.
3 Querying user groups from Active Directory for specific users caused an #18283
exception that the group could not be found. This issue has been fixed.
3 Update check for new PowerFactory releases now allows the exclusion of #16412
specific versions.
- PowerFactory now offers to download and update the activation file when #17023
certain types of licence errors occur during startup.
- LicenceManager now executes automatic firmware update for USB don- #17908
gles when necessary.
- A optional new Windows service now handles regular licence validation in #16976
a network licence environment (PowerFactory no longer requires online DIG23775
access for validation).
3 The 32-bit Offline Mode can now be installed on 64-bit machines. #15778
3 PowerFactory now handles cases where the PowerFactory.ini file is not #18237
found in the installation directory.
Description ID
- CodeMeter licence server can be started and stopped in the Network Set- #18030
tings dialog of the LicenceManager. DIG26032
- The option System Cryptography: Use FIPS compliant algorithms for en- #15982
cryption, hashing, and signing. is now disabled in the configuration set-
tings.
- Network proxy settings are now stored by default in the Windows registry #17086
instead of the INI file.
3 The Microsoft Visual C++ runtimes are now part of the application in- #17756
staller. DIG25145
3 The PowerFactory installer now ships the Visual C++ Redistributable #17752
package.
3 The installation now runs an Upgrade Assistant which helps migrate ap- #18099
plication settings from former versions.
3 Protection functions are now available with the Demo licence. #17365
6.3.22 Documentation
Description ID
Whats New
Tutorial (English)
New Technical Reference documents are available for:
4-Winding Transformer
Harmonic Filter
Step-Voltage Regulator
Result variables for load flow and RMS simulation
PWM Converter
Filter/Shunt
Static Var System (SVS)
Synchronous Machine
- The OPC guide and its examples have been changed. #15624
3 PDF reader SumatraPdf has been updated to the latest version 3.1.2. #16415
6.3.23 Examples
Description ID
- New application example videos are available in the Application Examples #18337
dialog.
- An application example for railway systems is available now in the Appli- #18339
cation Examples dialog.
Description ID
- A new Transmission System example is available in the Application Ex- #18340
amples dialog.
- Minor updates have been made to the following application examples: #18341
Hydro power plant example (EN and DE): Update of DSL models.
HVDC example: Improvement of external network settings.
Offshore wind farm example: Improvement of simulation step sizes
in EMT study case.
Wind farm example (EN and DE): Direction arrows in single-line di-
agram.
- Wind Farm example: Updated PDF files with short description of the #18581
Study Cases.
- Transmission System example: The background map used in the geo- #18582
graphic network diagram now uses OpenStreetMap.
- Offshore Wind Farm example: The PQ control block of the wind turbine #18577
models has been improved to run properly in the EMT simulation Study
Case.
- MV Distribution Network example: Unused lines have been removed from #18573
the example.
6.3.24 Miscellaneous
Description ID
Description ID
3 Workspace backups now omit temporary and caching data. #15218
- A new optimisation method using genetic algorithms has been introduced #15030
for Phase Balance Optimisation. More details are available in the Whats
New document.
3 The attribute cpFeed can now be accessed without an active calculation #15713
result.
- The Calculation of Initial Conditions command can be accessed from the #15822
simulation command via scripting. DIG22054
3 Enhanced internal linear solver to support matrices with very small values. #17524
This helps in cases such as when unbalanced short-circuit calculations DIG25162
are executed for a grid containing components with small impedances.
3 The default setting for Frequency Analysis has been changed to Fast #17552
Fourier Transform (FFT).
- Improved handling of triggered files shown in plots for the PFM master #17077
station. The data to be displayed can be selected from the list of trigger
events.
- The AC Optimal Power Flow calculation now also supports static var sys- #1481
tems as controls during the optimisation process.