Sei sulla pagina 1di 13

Saturday, February 09, 2013, 10:34 AM

PAGE NO. 1

****************************************************
* *
* STAAD.Pro *
* Version 2007 Build 04 *
* Proprietary Program of *
* Research Engineers, Intl. *
* Date= FEB 6, 2013 *
* Time= 15:35:40 *
* *
* USER ID: Home *
****************************************************

1. STAAD SPACE
INPUT FILE: Parcel 2.09.STD
2. START JOB INFORMATION
3. ENGINEER DATE 06-FEB-13
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 0 6; 3 3.5 0 0; 4 3.5 0 6; 5 0 3 0; 6 0 3 6; 7 3.5 3 0
9. 8 3.5 3 6
10. MEMBER INCIDENCES
11. 1 1 5; 2 2 6; 3 3 7; 4 4 8; 5 5 7; 6 7 8; 8 6 8; 10 5 6
12. ELEMENT INCIDENCES SHELL
13. 9 5 6 8 7
14. ELEMENT PROPERTY
15. 9 THICKNESS 0.125
16. DEFINE MATERIAL START
17. ISOTROPIC CONCRETE
18. E 2.17185E+007
19. POISSON 0.17
20. DENSITY 23.5616
21. ALPHA 1E-005
22. DAMP 0.05
23. END DEFINE MATERIAL
24. MEMBER PROPERTY
25. 1 TO 4 PRIS YD 0.2 ZD 0.4
26. 5 6 8 10 PRIS YD 0.4 ZD 0.2
27. CONSTANTS
28. MATERIAL CONCRETE ALL
29. SUPPORTS
30. 1 TO 4 PINNED
31. LOAD 1 LOADTYPE DEAD TITLE DEAD LOAD
32. SELFWEIGHT Y -1 LIST 1 TO 4 9
33. FLOOR LOAD
34. YRANGE 2.9 3.1 FLOAD -2.4 GY

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 1 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 2

**WARNING** about Floor/OneWay Loads/Weights.


Please note that depending on the shape of the floor you may
have to break up the FLOOR/ONEWAY LOAD into multiple commands.
For details please refer to Technical Reference Manual
Section 5.32.4 Note 6.

35. LOAD 2 LOADTYPE LIVE TITLE LIVE


36. FLOOR LOAD
37. YRANGE 2.9 3.1 FLOAD -2 GY
38. LOAD COMB 3 SLC
39. 1 1.0 2 1.0
40. LOAD COMB 4 ULC1
41. 1 1.4
42. LOAD COMB 5 ULC2
43. 1 1.2 2 1.6
44. LOAD COMB 6 LTDEF
45. 1 2.5 2 1.0
46. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 8/ 9/ 4

SOLVER USED IS THE IN-CORE ADVANCED SOLVER

TOTAL PRIMARY LOAD CASES = 2, TOTAL DEGREES OF FREEDOM = 36

47. START CONCRETE DESIGN

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 2 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 3

48. CODE ACI


49. CLB 0.04 MEMB 1 TO 6 8 10
50. CLS 0.04 ALL
51. CLT 0.04 MEMB 1 TO 6 8 10
52. FC 40000 ALL
53. FYMAIN 413688 MEMB 1 TO 6 8 10
54. FYSEC 413688 MEMB 1 TO 4
55. MAXMAIN 16 MEMB 1 TO 4
56. MINMAIN 12 MEMB 1 TO 4
57. MINSEC 10 MEMB 1 TO 4
58. REINF 0 MEMB 1 TO 4
59. DESIGN COLUMN 1 TO 4

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 3 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 4

====================================================================

COLUMN NO. 1 DESIGN PER ACI 318-05 - AXIAL + BENDING

FY - 413.7 FC - 40.0 MPA, RECT SIZE - 400.0 X 200.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 800.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

4 - 16 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 10 SPACING 200.00 MM

====================================================================

COLUMN NO. 2 DESIGN PER ACI 318-05 - AXIAL + BENDING

FY - 413.7 FC - 40.0 MPA, RECT SIZE - 400.0 X 200.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 800.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

4 - 16 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 10 SPACING 200.00 MM

====================================================================

COLUMN NO. 3 DESIGN PER ACI 318-05 - AXIAL + BENDING

FY - 413.7 FC - 40.0 MPA, RECT SIZE - 400.0 X 200.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 800.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

4 - 16 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 10 SPACING 200.00 MM

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 4 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 5

====================================================================

COLUMN NO. 4 DESIGN PER ACI 318-05 - AXIAL + BENDING

FY - 413.7 FC - 40.0 MPA, RECT SIZE - 400.0 X 200.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 800.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

4 - 16 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 10 SPACING 200.00 MM

********************END OF COLUMN DESIGN RESULTS********************

60. CLB 0.02 MEMB 9


61. CLT 0.02 MEMB 9
62. DESIGN BEAM 5 6 8 10

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 5 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 6

=====================================================================

BEAM NO. 5 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

LEN - 3500. MM FY - 414. FC - 40. MPA, SIZE - 200. X 400. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 12MM 247. 3107. NO NO


2 341. 3 - 12MM 0. 660. YES NO
3 341. 3 - 12MM 2694. 3500. NO YES

B E A M N O. 5 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 3.55 KNS Vc= 71.64 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 3.55 KNS Vc= 71.64 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 5J____________________ 3499X 200X 400_____________________ 7J____


| |
||============= =================||
| 3No12 H 341. 0.TO 660 3No12 H 341.2694.TO 3500 |
| |
| 3No12 H 59. 247.TO 3107 |
| =============================================================== |
| |
|___________________________________________________________________________|
_______ _______ _______ _______ _______ _______ _______
| | | | | | | | | | | | | |
| ooo | | ooo | | | | | | | | ooo | | ooo |
| 3#12 | | 3#12 | | | | | | | | 3#12 | | 3#12 |
| | | | | | | | | | | | | |
| | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | |
| | | ooo | | ooo | | ooo | | ooo | | ooo | | |
| | | | | | | | | | | | | |
|_______| |_______| |_______| |_______| |_______| |_______| |_______|

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 6 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 7

=====================================================================

BEAM NO. 6 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

LEN - 6000. MM FY - 414. FC - 40. MPA, SIZE - 200. X 400. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 12MM 559. 5191. NO NO


2 341. 3 - 12MM 0. 869. YES NO
3 341. 3 - 12MM 4881. 6000. NO YES

B E A M N O. 6 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 29.24 KNS Vc= 70.54 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 171. MM C/C FOR 2665. MM

AT END SUPPORT - Vu= 29.24 KNS Vc= 70.54 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 171. MM C/C FOR 2665. MM

___ 7J____________________ 6000X 200X 400_____________________ 8J____


| |
||========== ==============||
| 3No12 H 341. 0.TO 869 3No12 H 341.4881.TO 6000 |
| 17*12c/c171 17*12c/c171 |
| 3No12 H 59. 559.TO 5191 | | |
| =========================================================== |
| |
|___________________________________________________________________________|
_______ _______ _______ _______ _______ _______ _______
| | | | | | | | | | | | | |
| ooo | | | | | | | | | | ooo | | ooo |
| 3#12 | | | | | | | | | | 3#12 | | 3#12 |
| | | | | | | | | | | | | |
| | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | |
| | | ooo | | ooo | | ooo | | ooo | | ooo | | |
| | | | | | | | | | | | | |
|_______| |_______| |_______| |_______| |_______| |_______| |_______|

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 7 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 8

=====================================================================

BEAM NO. 8 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

LEN - 3500. MM FY - 414. FC - 40. MPA, SIZE - 200. X 400. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 12MM 247. 3107. NO NO


2 341. 3 - 12MM 0. 660. YES NO
3 341. 3 - 12MM 2694. 3500. NO YES

B E A M N O. 8 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 3.55 KNS Vc= 71.64 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 3.55 KNS Vc= 71.64 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 6J____________________ 3499X 200X 400_____________________ 8J____


| |
||============= =================||
| 3No12 H 341. 0.TO 660 3No12 H 341.2694.TO 3500 |
| |
| 3No12 H 59. 247.TO 3107 |
| =============================================================== |
| |
|___________________________________________________________________________|
_______ _______ _______ _______ _______ _______ _______
| | | | | | | | | | | | | |
| ooo | | ooo | | | | | | | | ooo | | ooo |
| 3#12 | | 3#12 | | | | | | | | 3#12 | | 3#12 |
| | | | | | | | | | | | | |
| | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | |
| | | ooo | | ooo | | ooo | | ooo | | ooo | | |
| | | | | | | | | | | | | |
|_______| |_______| |_______| |_______| |_______| |_______| |_______|

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 8 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 9

=====================================================================

BEAM NO. 10 DESIGN RESULTS - FLEXURE PER CODE ACI 318-05

LEN - 6000. MM FY - 414. FC - 40. MPA, SIZE - 200. X 400. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 12MM 559. 5191. NO NO


2 341. 3 - 12MM 0. 869. YES NO
3 341. 3 - 12MM 4881. 6000. NO YES

B E A M N O. 10 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 29.24 KNS Vc= 70.54 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 171. MM C/C FOR 2665. MM

AT END SUPPORT - Vu= 29.24 KNS Vc= 70.54 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= 2.1 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 171. MM C/C FOR 2665. MM

___ 5J____________________ 6000X 200X 400_____________________ 6J____


| |
||========== ==============||
| 3No12 H 341. 0.TO 869 3No12 H 341.4881.TO 6000 |
| 17*12c/c171 17*12c/c171 |
| 3No12 H 59. 559.TO 5191 | | |
| =========================================================== |
| |
|___________________________________________________________________________|
_______ _______ _______ _______ _______ _______ _______
| | | | | | | | | | | | | |
| ooo | | | | | | | | | | ooo | | ooo |
| 3#12 | | | | | | | | | | 3#12 | | 3#12 |
| | | | | | | | | | | | | |
| | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 | | |
| | | ooo | | ooo | | ooo | | ooo | | ooo | | |
| | | | | | | | | | | | | |
|_______| |_______| |_______| |_______| |_______| |_______| |_______|

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 9 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 10

********************END OF BEAM DESIGN**************************

63. DESIGN ELEMENT 9

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 10 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 11

ELEMENT DESIGN SUMMARY


----------------------

ELEMENT LONG. REINF MOM-X /LOAD TRANS. REINF MOM-Y /LOAD


(SQ.MM/MM) (KN-MM/MM) (SQ.MM/MM) (KN-MM/MM)

FY: 413.682 MPA FC: 40.000 MPA COVER: 20.000 MM TH: 125.000 MM
9 TOP : Longitudinal direction - Only minimum steel required.
9 BOTT: Longitudinal direction - Only minimum steel required.
9 TOP : Transverse direction - Only minimum steel required.
9 BOTT: Transverse direction - Only minimum steel required.
9 TOP : 0.225 0.00 / 0 0.225 0.00 / 0
BOTT: 0.225 1.44 / 6 0.225 0.91 / 6

***************************END OF ELEMENT DESIGN***************************

64. END CONCRETE DESIGN


65. FINISH

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= FEB 6,2013 TIME= 15:35:41 ****

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 11 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 12

************************************************************
* For questions on STAAD.Pro, please contact *
* Research Engineers Offices at the following locations *
* *
* Telephone Email *
* USA: +1 (714)974-2500 support@bentley.com *
* CANADA +1 (905)632-4771 detech@odandetech.com *
* UK +44(1454)207-000 support@bentley.com *
* NORWAY +47 67 57 21 30 staad@edr.no *
* SINGAPORE +65 6225-6158 support@bentley.com *
* INDIA +91(033)4006-2021 support@bentley.com *
* JAPAN +81(03)5952-6500 eng-eye@crc.co.jp *
* CHINA +86(411)8479-1166 support@bentley.com *
* THAILAND +66(0)2645-1018/19 support@bentley.com *
* *
* North America support@bentley.com *
* Europe support@bentley.com *
* Asia support@bentley.com *
************************************************************

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 12 of 13


Saturday, February 09, 2013, 10:34 AM
STAAD SPACE -- PAGE NO. 13

D:\ROY\PPA-10\ppa 10\P 2.06 electrical\STAAD\Parcel 2.09.anl Page 13 of 13

Potrebbero piacerti anche