Contents
Secondary Steelwork
and Bracket Production 12
Certifications 14
Extendable Pole
CFS
Construction Fixing Systems
Safety Lanyard
CERTIFICATE NO: CFS-0000/JUH
Notes
CFS provides a comprehensive Site Testing Service. We can load Test up to 12.5T
Please note beams were supplied by CFS
Eyes were welded on before beam was fitted
Test Certificates are provided
Construction Fixing Systems Ltd.
T
Unit 2A Westfield Estate Henley Road Medmenham Marlow Bucks SL7 2TA
We offer a rapid response time
T
ests are conducted by means of tensioned chain to the lift pit or the top of the
slab accessed through door openings
ll operatives have CSCS cards and will liaise carefully with the contractor to
A
establish the most suitable test method
Method statements and risk assessments provided on request
Members of LEEA.
The CFS range is suitable for all types of structure: new concrete, existing and steel framed. 4.0T 30mm CASP-30 NR-40 RE-30 42
Please specify
CFS is able to offer component supply and a supply and site Test Service. *_Length (H) slab thickness
Cast-in Inserts Stud Bearing Plate for use with existing slabs
for use with Non-rotating eyes W Lock
Crown Foot Anchor Cast-in Socket please specify slab thickness H nut
5 www.cfsfixings.com www.cfsfixings.com 6
Systems for Steelwork Applications Metal Deck Flooring
Steel Beams with Pre-fixed Lift Suspension Eyes Beams can be supplied to suit your load criteria
and fixing details
Please specify eye positions and overall length of beam
to ensure adequate bearing on your block or brick walls. Metal Deck Profile
For Folding Eyes specify the direction of fold.
CFS can advise on beam sizes.
Non-rotating Eye Folding Type FE
Excellent load transmission to the existing structure
Folds flat, ideal for restricted height applications Bearing on Block Walls
I ncorporatesa bump stop to ensure the eye can only fold
one way. Enables easy hooking into the eye by operatives.
SECTION DETAIL
1. 2. 3.
160
0m
mt
o2
000
mm
1100mm Dimensions to Suite Rib Centres
1. R
otating eye with packer plate bolted to beam.
PLAN VIEW UNDERSIDE SLAB
2. N
on-rotating eye for bolting to steel beams.
Type NBR. Please specify beam size.
3. N
on-rotating eye for welding to steel beams. Adjustable beams for varying
Type NR. Please specify beam size. lift shaft widths.
7 www.cfsfixings.com www.cfsfixings.com 8
Lift Structures
Freestanding, Restrained Structures
For use in timber or other buildings where lift loads are to
CFS Divider Screens CFS Fascia Panels
be taken independently from the main building structure. Manufactured to BS EN ISO 13857 : 2008 & EN81-1/2 clause 5.3.1
Manufactured to EN81-1/2 clause 5.4 & 11.2
www.cfsfixings.com 10
HSS Cobalt Drill Bits
for metal Channel Systems
Plain back Channels
for Welding to Steel Structures
Plain Back Channels Typical Length Triple Channel Assemblies Typical Length
PBB 40 (40/25) 550, 800, 1100, 1300 TCH 40 (40/25) 550, 800, 1100, 1300
max 3000mm max 3000mm
PBB 50 (49/30) 550, 800, 1100, 1300 TCH 50 (49/30) 550, 800, 1100, 1300
max 3000mm max 3000mm
PBBH C.W. Fixing cleats for bolting to block walls. Please consult CFS
cast-in inserts c
c
c
b b
b
Utilises pre-cast blocks manufactured
to suit site dimensions
a
Savesa time-consuming site casting
Drill Fixings for Guide Rails of padstones within block
c
walls. Please specify
CFS has the Fischer Range of Tested Products Please
b specify your dimensions.
c
dimensions a, b, c.
b a
Together with Fischer UK, Part No. Resin Pack Size Application
CFS have developed a wide range 94405 FIS V 360 S 6 For resin anchor c
of post drilled fixings, providing studs
Channels for fixing to lightweight metal deck floors
b
Part No. TL Resin Studs Pack Size Application Concrete Dense Block Brickwork
42727 TL RESIN STUD M12 10 Stud for use
with resin
Part No. CFS S-Fix Pack Size Application Concrete Dense Block Brickwork
M12 S-FIX M12 S-FIX 1 For block
M16 S-FIX M16 S-FIX rapid fixing
Part No. FBN II Through Bolt Pack Size Application Concrete Dense Block Brickwork
94405 FIS V 360 S 20 Bolt for
concrete wall www.cfsfixings.com 12
Cast-in Insert Systems Certifications
Typically for Guide Rail and Door Fixing
Clip Clamp
T-bolts to Suit Channels
Part No. Finish
Back to back
40/25 M12 x 50 M12 x 60 M12 x 80 Electroplated Angles Guide Rail
TB M16 x 60 M12 x 60 M16 x 80
49/30 M16 x 50 M16 x 60 M16 x 80 Electroplated
TB M20 x 60 M20 x 100
All supplied c/w nut. Spun galvanised grade 8.8 available on request.
Other channel sizes available on request.
Part No. 40/25 Cast-in Channel Pack Size Part No. T Bolts 40/25 Pack Size
CH40-200 40/25 HDG Channel 200mm 1 TB40-12-50 40/25 M12 x 50 1
CH40-550 40/25 HDG Channel 550mm 1 TB40-12-80 40/25 M12 x 80 1
CH40-800 40/25 HDG Channel 800mm 1 TB40-12-100 40/25 M12 x 100 1
CH40-1100 40/25 HDG Channel 1100mm 1 TB40-16-50 40/25 M16 x 50 1
CH40-1300 40/25 HDG Channel 1300mm 1 TB40-16-80 40/25 M16 x 80 1 For more information
CH40-1550 40/25 HDG Channel 1550mm 1 TB40-16-100 40/25 M16 x 100 1
on our Lift Product
CH40-1800 40/25 HDG Channel 1800mm 1 Part No. T Bolts 50/30 Pack Size
Part No. 50/30 Cast-in Channel Pack Size TB50-16-50 50/30 M16 x 50 1 range or to see
CH50-200 50/30 HDG Channel 200mm 1 TB50-16-80 50/30 M16 x 80 1
CH50-550 50/30 HDG Channel 550mm 1
other services CFS
CH50-800 50/30 HDG Channel 800mm 1 can offer, please visit
CH50-1100 50/30 HDG Channel 1100mm 1
CH50-1300 50/30 HDG Channel 1300mm 1
CH50-1550 50/30 HDG Channel 1550mm 1
www.cfsfixings.com
CH50-1800 50/30 HDG Channel 1800mm 1
13 www.cfsfixings.com www.cfsfixings.com 14
Construction Fixing Systems Limited
Unit 2A, Westfield Estate, Henley Road, Medmenham, Marlow, Buckinghamshire SL7 2TA. UK
Telephone. +44 (0) 1491 576466
Fax. +44 (0) 1491 578166
Email. sales@cfs-fixings.co.uk
www.cfsfixings.com