Sei sulla pagina 1di 32

AR-721U/721K/661U

Users Guide

Feb. 6, 2004
Table of Contents
Page
1. Main Feature --------------------------------- 3
2. AR-721U Installation --------------------------------- 4
2.1 Steps --------------------------------- 4
2.2 Installation Notice --------------------------------- 5
2.3 Wiring --------------------------------- 6
2.4 PCB board ----------------------------------8
2.4.1 No waterproof --------------------------------- 8
2.4.2 Waterproof --------------------------------- 8
2.5 Installation diagram ----------------------------------9
2.5.1 AR-721U & AR-721H ------------------- 9
2.5.2 AR-721U & AR-727H ------------------- 10
2.5.3 AR-721U & AR-821EF ------------------- 11
2.5.4 AR-721U & AR-829E ------------------- 12
3. AR-721K Installation -------------------------------- 13
3.1 Steps -------------------------------- 13
3.2 Installation Notice -------------------------------- 14
3.3 Wiring -------------------------------- 15
3.4 PCB board -------------------------------- 16
3.5 Installation diagram -------------------------------- 17
3.5.1 AR-721K & AR-721H ------------------- 17
3.5.2 AR-721K & AR-727H ------------------- 18
3.5.3 AR-721K & AR-821EF ------------------- 19
3.5.4 AR-721K & AR-829E ------------------- 20

1
4. AR-661U Installation -------------------------------- 21
4.1 Installation Notice -------------------------------- 21
4.2 Wiring -------------------------------- 22
4.3 Installation diagram -------------------------------- 23
4.3.1 AR-661U & AR-721H ------------------- 23
4.3.2AR-661U & AR-727H ------------------- 24
4.3.3AR-661U & AR-821EF ------------------- 25
4.3.4AR-661U & AR-829E ------------------- 26
4.4 The standalone controller do anti-pass-back with
2 pcs of AR-661U -------------------------------- 27
4.5 Testing table of AR-661U Reading Range depends
on tags -------------------------------- 29
5 Troubleshooting -------------------------------- 30
6 Return of Products -------------------------------- 30
7 Warranty -------------------------------- 31

2
1. Main Features

Easily integrated with soyal or other access control systems.

Programmable various outputs formats Wiegand, magstripe or

serial.

Built-in watchdog to prevent the system from halting


A bi-color LED indicator and a beep sound.

Item AR-721U AR-721K AR-661U


Reading Range About 8 cm About 15 cm 33-60 cm
(Depends on tags)
Output Formats WG 26 / 34, ABA II, ASYNC 9600, N, 8, 1
Voltage 9-18VDC
Current < 1W < 2.5W < 4W
RF Frequency 125KHz
Environment -10 to +50
LED Indicators
Beep Sound
Keypad X 12 Keys X
Material ABS ABS ABS
Waterproof Option X
Dimensions (mm) 80(L)43(W)15(H) 112(L)*76(W)*25(H) 230(L)*230(W)*35(H)

3
2. AR-721U Installation

2.1 Steps

1. Use the screwdriver to screw the mounting plate on the wall.

2. Pull cable ends through the access hole in the mounting plate.

AR-721U must be connected before power is applied to the

single door controller.

3. Attach the AR-721U to the mounting plate.

4. Apply power. The red LED will flash once and the beeper will

sound.

4
2.2 Installation Notice

1. AR-721U is narrow enough to mount to most mullions and door

frames.

2. Single door controller locate inside the secure area for use as an

exit controller, the auxiliary reader locate exterior wall for use as

an entrance reader, but not directly behind single door controller.

For best reading distance, offset the single door controller and

auxiliary reader by about 50 cm above and 12 m below

(suggestion value).

3. Normally, AR-721U will read a Card / Key Tag at up to 8 cm.

However, when AR-721U reader is mounted directly on a metal

surface, the reading distance decreases slightly. To reduce this

effect, install wood or plastic between the mounting surface and

mounting plate, this will restore most of the reading distance.

5
2.3 Wiring

Table 1 - Color Coding

Wire Application Wire Color Description

Power 1 Red DC Power 12V

2 Black DC Power 0V

LED 3 Yellow LED Red Input ( Low Bright)

4 Brown LED Green Input ( Low Bright)

Wiegand 5 Blue Wiegand DAT:1

6 Green Wiegand DAT:0

Beeper 7 Purple Beeper Input ( Low Sound )

8 White Card Present

Beeper 9 Gray Beeper Output

Output Selection

Output WG26 WG34 RS-232 Magnetic ( ABA )

34/26 Open Close Open Close

ABA Open Open Close Close

6
AR-721U RS-232 Format: ( 9600,N, 8, 1 SOYAL Format )

DAT:0: TTL Inverted Serial Output.

( Can connect to PC comm port )

DAT:1: TTL Serial Output.


( connect to PC comm. port through RS-232 invert driver )

7
2.4 PCB board
2.4.1 No waterproof

Output Format
ABA 34126 ABA 34126

WG 26 (Default)
ABA 34126

WG 34
721U PCB ABA 34126

RS-232
ABA 34126

ABAII
Buzzer

2.4.2 Waterproof

Output Format

Connect for WG34 bit (Default)

Cut for WG26 bit

Buzzer

AR-721U

8
The installation of 721H and auxiliary reader 721U
RELAY

CN4

721H5DS
P1

P2

B A 7AC2
CN2
CN1
2.5 Installation diagram
2.5.1 AR-721U & AR-721H

CN2
CN1

9
Red

Black
CN3

AR-721U SOYAL

-GND Black
A Pin Color B Pin Function +12VDC Red
1 Blue Blue DAT:1
2 Green Green DAT:0
3 Pink Purple Beeper input Power Supply
4 Brown Brown Green LED
Yellow Yellow Red LED
12VDC 500mA
5
The installation of 727H and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
Red
2.5.2 AR-721U & AR-727H

Red(+12VDC)
Blue

10
Green
Brown
Purple
Yellow

Black(-GND) CN3
1 Yellow Yellow
727H

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN1
Blue Blue

661U
The installation of 821EF and auxiliaryreader 721U
Red(+12VDC)

Black(-GND)

Black(-GND)

Red(+12VDC)

P1
Red(+12VDC)
Black(-GND)

CN1
P2

A
CN2

TP1 Power Supply


12VDC 2A
2.5.3 AR-721U & AR-821EF

821EF
~

CN2

11
CN3 CN1 1

CN7 +3V
B

A Pin Color B Pin Function


3 Blue Blue DAT:1
4 Green Green DAT:0
5 Pink Purple Beeper Input
6 Brown Brown Green LED
7 Yellow Yellow Red LED
The installation of 829E and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
Red
2.5.4 AR-721U & AR-829E

Red(+12VDC)
Blue

12
Green
Brown
Purple
Yellow

Black(-GND) CN1
1 Yellow Yellow
829E

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN2
Blue Blue

661U
3. AR-721K Installation
3.1 Steps
1. Use the screwdriver to screw the mounting plate on the wall.

2. Pull cable ends through the access hole in the mounting plate.

AR-721K must be connected before power is applied to the

single door controller.

3. Connect plug P1 to socket CN1 on the AR-721K circuit board.

Connect plug P2 to socket CN2 on the AR-721K circuit board.

Connect plug P3 to socket CN3 on the AR-721K circuit board.

4. Attach the AR-721K to the mounting plate and install screw

(supplied) into the hole at the bottom with the Allen wrench

(supplied).
5. Apply power. The red LED will flash once and the beeper will
sound. Refer to beginning of this manual for programming.

13
3.2 Installation Notice

1. Single door controller locate inside the secure area for use as an

exit controller, the auxiliary reader locate exterior wall for use as

an entrance reader, but not directly behind single door controller.

For best reading distance, offset the single door controller and

auxiliary reader by about 50 cm above and 12 m below

(suggestion value).

2. Normally, single door controller will read a Card / Key Tag at up

to 15 cm. However, when single door controller or optional

auxiliary reader is mounted directly on a metal surface, the

reading distance decreases slightly. To reduce this effect, install

wood or plastic between the mounting surface and mounting

plate, this will restore most of the reading distance.


3. AR-721K can cover standard electrical boxes.

14
3.3 Wiring

Table 1 - Connector P1 Color Coding

Wire Application Wire Color Description

Power 1 Thick Red DC Power 12V

2 Thick Black DC Power 0V

Table 2 - Connector P2 Color Coding (Wiegand Read Head )

Wire Application Wire Color Description

Wiegand 1 Thin Blue Wiegand DAT:1 Input

ABA ABA Format:Clock

2 Thin Green Wiegand DAT:0 Input

ABA Format:Data

3 Orange ABA Format Card Present

4 No Connection
Beeper
5 Pink Beeper Input ( Low Sound )

LED 6 Brown LED Green Input ( Low Bright)

7 Yellow LED Red Input ( Low Bright)

15
Table 3 - Connector P3 Color Coding (Tamper Switch )

Wire Application Wire Color Description


Tamper Switch
1 Red N.C.

2 Orange COM

3 Yellow N.O.

3.4 PCB board

Output Format
WG J2 BIT(26/34)

Buzzer WG 26 (Default)
WG J2 BIT(26/34)
721K WG 34
1FF9
WG J1 J2 J3

WG J2 BIT(26/34)
WG 34
BIT(26/34)

WG J2 BIT(26/34)
ABA 10
J3
SOYAL Format
J3
EM Format (Default)

16
The installation of 721H and auxiliary reader 721K
Yellow(LED)
Brown(LED)
Pink (ALM)
Green(DAT:0)
Blue(DAT:1)
RELAY

CN4
721K
CN4

721H5DS
P1
CN1

7AC2 7AC2
P2

P2
CN2

CN2
3.5 Installation diagram

Blue White (N.O)


3.5.1 AR-721K & AR-721H

White (COM)

CN2
CN2

~
CN1

CN1

17
-GND
+12VDC

P1
CN1

CN3

Power Supply
CN3

Red

Black

12VDC 2A
SOYAL SOYAL

-GND Black
Power Supply
12VDC 500mA +12VDC Red
Gray
+12VDC -GND
ALM +12VDC
COM +12VDC

N.O -GND
N.C
The installation of 727H and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
Red
3.5.2 AR-721K & AR-727H

Red(+12VDC)
Blue

18
Green
Brown
Purple
Yellow

Black(-GND) CN3
1 Yellow Yellow
727H

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN1
Blue Blue

661U
Red(+12VDC) The installation of 821EF and auxiliaryreader 721K
Black(-GND) Blac
k(-G
ND)
R ed
(+1
Black(-GND) 2VD
C)

Red(+12VDC)
Power Supply
12VDC 2A

P1
CN1
P2

A
CN2

TP1
3.5.3 AR-721K & AR-821EF

821EF
~

CN2
CN3 1

19
CN1
CN4

721K
27BF
P2

B
CN2

CN7 +3V
CN2
P1
CN1

~
CN1

A Pin Color B Pin Function


3 Blue 1 DAT:1
CN3

4 Green 2 DAT:0
5 Pink 5 Beeper Input SOYAL

6 Brown 6 Green LED


7 Yellow 7 Red LED
The installation of 829E and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
Red
3.5.4 AR-721K & AR-829E

Red(+12VDC)
Blue

20
Green
Brown
Purple
Yellow

Black(-GND) CN1
1 Yellow Yellow
829E

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN2
Blue Blue

661U
4. AR-661U Installation
4.1 Installation Notice
Minimum distance between AR-661U & other proximity Reader
( 200cm )

1 2 3

4 5 6

7 8 9

* 0 #

R>200CM

21
4.2 Wiring

Table - Color Coding

Wire Application Wire Color Description Remark

Power 1 Red 12-18VDC regulated

2 Black Power Ground

Wiegand 3 Blue Wiegand DAT:1 Open collected

4 Green Wiegand DAT:0 Open collected

5 White Card Present

Beeper 6 Purple Beeper Output

Output Selection 7 Yellow SEL1

8 Brown SEL2

Output Selection

Output WG26 WG34 RS-232 WG34 + 4

SEL1 Open Close to GND Open Close to GND

SEL2 Open Open Close to GND Close to GND

NOTE:
WG34 + 4 : follow 0101 after WG34 data stream for reader
identification. (Anti-pass-back)
See Also: AR-721H do anti-pass-back with 2 pcs of AR-661U

22
The installation of 721H and auxiliary reader 661U
RELAY

CN4

721H5DS
P1

P2

B A 7AC2
CN2
CN1
4.3 Installation diagram
4.3.1 AR-661U & AR-721H

~
CN2
CN1

23
Red

Black
CN3

SOYAL

-GND Black

+12VDC Red
A Pin Color B Pin Function
1 Blue Blue DAT:1 Power Supply
2 Green Green DAT:0 12VDC 500mA
The installation of 727H and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
Red
4.3.2 AR-661U & AR-727H

Red(+12VDC)
Blue

24
Green
Brown
Purple
Yellow

Black(-GND) CN3
1 Yellow Yellow
727H

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN1
Blue Blue

661U
Red(+12VDC) The installation of 821EF and auxiliaryreader 661U
Black(-GND)
Power Supply Black(-GND)
12VDC 2A
Red(+12VDC)

P1
CN1
P2

A
CN2

TP1
4.3.3 AR-661U & AR-821EF

Power Supply
12VDC 2A
821EF
~

CN2

25
CN3 CN1 1

CN7 +3V
B

A Pin Color B Pin Function


3 Blue Blue DAT:1
4 Green Green DAT:0
The installation of 829E and auxiliary readers
Power Supply
12VDC 2A

721U
Black
1
4.3.4 AR-661U & AR-829E

Red

Red(+12VDC)
Blue

26
Green
Brown
Purple
Yellow

Black(-GND) CN1
1 Yellow Yellow
829E

Red
Black
Brown Brown
~

721K
CN1
CN2 Pink Pink
Green Green
CN2
Blue Blue

661U
4.4 The standalone controller do anti-pass-back with 2 pcs of
AR-661U
Standalone controller includes AR-721H, AR-727H and AR-829E.
And here is AR-721H & 2 pcs AR-661U diagram.

AR-721H do anti-pass-back with 2 pcs of AR-661U

Yellow
White
Purple
Green
Bule
Black
Red

Green

Blue Red

Yellow
White
Black
Purple
Green
Bule
Black
Red

Output Selection

27
When the distance between 2 pcs 661U is less than 6 meter
(suggestion value), we can use the following ways to solve in order
to avoid interference with each other to result in reading distance
decrease.

Slaver
Two AR-661U Reader WIRING (RF switching)

GND RF SYNL

Cable

Single Reader (RF always ON)


Master
Output
GND RF SYNL

GND RF SYNL
AR-661U Partial drawing

28
4.5 Testing table of AR-661U Reading Range depends on tags

Testing circumstances: Voltage 12V/500mA, No other jamming


in 5 meters.

Testing
Sample Maximum Minimum Average
Item no. Name Distance
S/N (cm) (cm) (cm)
(cm)

1 35
AR-701KPC Key-chain
2 37 38 35 36.5
RW-2 (R/W)
3 38

1 56
AR-2561 Thick Card
2 55 60 55 57.5
TRW (R/W)
3 60

AR-8972 ISO 1 40
ISO Card 42 40 41
RW 2 42

Long distance 1 66
AR-2563
Card 2 65 66 56 61
TRL
(Read Only) 3 56

29
5. Troubleshooting

Questions Answer
No appearance 1. Check power, if it is 9 18 VDC adaptor?
2. Check if the polarity is correct?
3. The unit should make a beep sound when
any key on the keypad is depressed
(AR-721K).

6. Return of Products
If you think that you have a defective unit, please contact the
distributor who sold you the unit. All service and repairs must be
done through an authorized distributor.

30
7. Warranty
SOYAL warrants that the product(s) shall be free from manufacturing

defects in materials and workmanship for a period of fifteen (15)

month from the date of delivery provided that the product was

properly installed and used. The foregoing warranty shall not apply

to defects resulting from abuse, misuse, accident, unauthorized

alteration or repair, neglect, acts of God (such as floods, fire, etc.).

SOYAL shall, at its option, either repair or replace product(s) which

prove to be defective within the warranty period. SOYAL will replace

any product found to be defective within the first three months of

purchase provided said product was properly installed and used.

Distributor agrees to insure the product or assume the risk of loss or

damage in transit to prepay shipping charges and to use the original

shipping container or equivalent. Customers shall seek assistance

from the distributor who sold you product(s). Repaired or replaced

product(s) are warranted for ninety (90) days from the date of repair

or replacement, or for the remainder of the original products

warranty period, whichever is longer.

Note: Dont tear a paster such as S/N: 721K-08336 on the PCB

board, because it is SOYAL warranty.

31

Potrebbero piacerti anche