Sei sulla pagina 1di 11

ESCUELA POLITCNICA NACIONAL

FACULTAD DE INGENIERA MECNICA

LABORATORIO DE MECNICA FLUIDOS Y TURBOMQUINAS

1. Ttulo de la Prctica:

2. Grupo: Gr 8 viernes 9-11.

2.1. Integrantes: Arias Ledesma Francisco Alexander


Mosquera Guerra Lized Alexandra

2.2. Fecha de realizacin de la prctica: 17-noviembre-2017

2.3. Fecha de entrega del informe: 24-noviembre-2017

3. Abstract

This report shows a basic study of axial fans. The analysis is based on two tests of its
operation. One of them at constant speed and the other with constant fan opening. The
results are taken by special software and plotted to find the characteristic curves of the
equipment, these are: performance vs flow, pressure vs flow and useful power vs flow,
where the operating point will be observed.
It should also be considered that the calculation of the arrow work is facilitated since the
sensors are in a control volume where their section is uniform, therefore the input and output
speeds are equal so the kinetic energy factor is eliminated and by the size of the fan, friction
losses are negligible.

4. Introduccin

Un ventilador es una turbomquina que mantiene un flujo continuo, que por lo general es
un fluido en estado gaseoso. Su funcionamiento se basa en absorber energa mecnica
para proporcionar un incremento de presin al fluido, originando una pequea variacin del
volumen especfico del mismo.
El uso ms comn que se le da a los ventiladores es el de refrescar un ambiente habitado
donde las temperaturas son relativamente altas.
Otro de las aplicaciones es como intercambiador de calor, ya sea como disipador o radiador
con el fin de aumentar la transferencia de calor entre dos elementos o sustancias.
Los ventiladores se pueden clasificar de varias maneras, una de ellas es segn la
trayectoria del aire, que los divide en ventiladores axiales, centrfugos, transversales y
helicocentrfugos.
Los ventiladores se caracterizan por el movimiento del flujo a travs del rotor, paralelo al
eje de rotacin. Este sistema es apropiado para sistemas con flujos altos y presiones bajas.
El campo principal de aplicacin de los ventiladores axiales es el de la ventilacin,
calefaccin.
Dentro de lo ventiladores axiales, se encuentra una subclasificacin:
Holicoidal
Tube Axial
Vane Axial
Centrifoil

5. Preguntas

5.1. Realice un esquema y describa el funcionamiento de los ventiladores contra


rotatorios.

Fig.1. Esquema de ventiladores

El ventilador contra rotatorio es una variante del ventilador de tubo axial. Se caracteriza
porque utiliza su potencia para generar energa con el objetivo de aumentar la presin de
entrega de aire en condiciones de mucha resistencia.
Este sistema consiste en colocar dos o ms ventiladores si aletas guas y con rotores de
tal forma que giren en direccin contraria y alternada, como se puede apreciar en la figura
1.

5.2. Cul es el rendimiento general de ventiladores axiales.

El rendimiento de un ventilador est en funcin de la energa absorbida por el aiere y la


energa elctrica suministrada al motor.

=

Pu= Energa absorbida
Pe= Energa suministrada

5.3. Describe las curvas caractersticas de los ventiladores en serie.

Un acoplamiento en serie consiste en conectar los ventiladores de forma continua. Tambin


se los puede conectar de un mismo conducto siempre y cuando el flujo del aire sea
unidireccional.
La curva caracterstica de los ventiladores en serie es aproximadamente doble de una
curva de un solo ventilador, como se observa en la figura 2.
Fig.2. Curva caracterstica de ventiladores

Para calcular la presin resultante se obtiene sumando las ordenadas de la presin esttica
del primer ventilador a las de presin total del segundo: PE = Pe + Pt. Esto se puede
verificar en la figura 3.

Fig.3. Curva caracterstica del ventilador axial

5.4. Describe 5 aplicaciones de los ventiladores axiales en Ingeniera Mecnica.

1. Sistema de refrigeracin de coches: radiador


2. Instalaciones de ventilacin en cabinas de pintura
3. Sistemas de recirculacin de alta temperatura en hornos
4. Ventilacin de naves industriales y tneles
5. Ventilacin forzada para calderas o ventilacin industrial

5.5. Describa la clasificacin de ventiladores segn su uso.


FUNCIN VENTILADOR
Ventiladores que trasladan aire entre dos ventiladores Murales
espacios
Ventiladores diseados para trabajar en Ventiladores Especiales
ambientes corrosivos, hmedos o tratar aire
caliente. Ventiladores Estndar
Dedicados al transporte neumtico.
Aplicada en la extraccin y circulacin de aire Ventiladores Axiales
en naves industriales. helicoidales
Trabajan con objetivo de renovar el aire.
Aire acondicionado Ventiladores Tube Axial
Calefaccin
Ventilacin Ventiladores Vane Axial
Climatizadores
Sistemas industriales: cabinas de pintura y Ventiladores Centrifoil
extracciones localizadas de humos.
Ventiladores de Baja Presin

6. Datos Obtenidos

Tabla.1. Datos obtenidos con el ventilador a velocidad constante

Fan Fan Air Orifice Fan Motor Density Fan


Setting Speed Temperature Differential Differential Power of Air Discharge
S n T Pressure Pressure Pe Q
[%] [rpm] [C] [Pa] [Pa] [W] [kg/m] [l/s]

60 2099 18,0 18,4 16,4 1,8 1,197 25,9


60 2099 17,9 15,7 17,7 1,8 1,197 24,0
60 2099 17,9 13,5 20,0 1,8 1,198 22,2
60 2039 17,8 3,4 24,7 1,8 1,198 11,2
60 2099 17,9 0,3 26,2 1,8 1,198 3,3
60 2039 18,0 0,0 27,8 1,9 1,197 0,0
70 2340 18,0 23,4 19,8 2,0 1,197 29,2
70 2278 17,9 16,7 25,2 2,1 1,197 24,7
70 2278 17,9 2,3 30,5 2,0 1,197 9,2
70 2278 18,0 1,0 31,2 2,1 1,197 6,0
70 2218 18,0 0,3 31,8 2,1 1,197 3,3
70 2278 18,0 -0,1 34,2 2,2 1,197 1,5
80 2579 18,0 27,6 24,5 2,3 1,197 31,8
80 2519 18,0 19,2 29,4 2,3 1,197 26,5
80 2519 18,0 3,5 37,0 2,3 1,197 11,3
80 2519 18,0 1,8 36,5 2,3 1,197 8,2
80 2519 18,0 0,4 38,3 2,3 1,197 3,7
80 2459 18,1 -0,1 40,5 2,5 1,197 1,5
90 2698 18,1 34,2 28,0 2,6 1,196 35,4
90 2698 18,1 25,4 33,9 2,6 1,197 30,5
90 2758 18,1 17,8 34,4 2,5 1,197 25,5
90 2698 18,0 2,3 42,6 2,6 1,197 9,1
90 2638 18,1 0,3 45,4 2,6 1,197 3,3
90 2638 18,1 -0,1 47,0 2,8 1,196 1,5
100 2879 18,1 34,7 31,0 2,8 1,197 35,7
100 2818 18,1 24,7 38,3 2,8 1,197 30,1
100 2818 18,1 3,6 45,9 2,8 1,197 11,5
100 2818 18,1 1,5 48,4 2,8 1,197 7,5
100 2879 18,1 0,4 49,9 2,8 1,196 3,9
100 2758 18,2 -0,1 52,1 3,0 1,196 1,5

Tabla.2. Datos obtenidos con apertura constante

Fan Fan Air Orifice Fan Motor Density Fan


Setting Speed Temperature Differential Differential Power of Air Discharge
S n T Pressure Pressure Pe Q
[%] [rpm] [C] [Pa] [Pa] [W] [kg/m] [l/s]

60 2099 18,1 18,1 17,1 1,8 1,197 25,8


70 2278 18,0 22,4 20,9 2,0 1,197 28,6
80 2519 18,0 26,6 24,5 2,3 1,197 31,2
90 2698 18,1 31,7 29,1 2,6 1,197 34,1
100 2818 18,1 34,8 31,1 2,8 1,197 35,7
60 2099 18,0 14,9 19,5 1,8 1,197 23,4
70 2340 18,0 18,7 24,1 2,1 1,197 26,1
80 2519 18,0 22,9 28,3 2,3 1,197 29,0
90 2758 17,9 26,7 33,3 2,6 1,197 31,3
100 2758 17,9 29,3 36,0 2,8 1,197 32,8
60 2099 18,0 9,7 20,3 1,7 1,197 18,8
70 2340 18,1 12,2 24,8 2,0 1,197 21,2
80 2579 18,0 14,3 30,2 2,2 1,197 22,9
90 2758 18,0 16,9 35,2 2,5 1,197 24,8
100 2879 18,0 19,2 38,3 2,7 1,197 26,5
60 2099 18,1 0,7 25,7 1,8 1,197 5,0
70 2278 18,1 0,8 31,8 2,1 1,197 5,4
80 2459 18,1 1,0 38,9 2,3 1,197 6,0
90 2698 18,1 1,0 44,2 2,6 1,196 6,2
100 2758 18,1 1,2 48,4 2,8 1,197 6,5
60 2039 18,2 -0,1 28,3 1,9 1,196 1,5
70 2218 18,3 0,0 33,4 2,2 1,196 0,0
80 2399 18,4 -0,1 41,0 2,5 1,195 1,5
90 2579 18,5 0,0 47,9 2,8 1,195 0,0
100 2758 17,6 -0,1 51,8 3,0 1,199 1,5

7. Ejemplo de Clculos

Potencia til
=

= Potencia til del ventilador [W]


= Potencia total del ventilador [W]
l
= caudal de aire [ ]
s
1 3
= 16[] 25,9 [ ]
1000

= 0,4288 []

Rendimiento

= 100%

=
= Potencia til del ventilador [W]
= Potencia del motor del ventilador [W]

0,4288 []
= 100%
1,8 []

= 23,82%

8. Tabla de resultados

Tabla.3. Datos calculados con el ventilador a velocidad constante

Fan Fan Fan Fan Fan Overall


Setting Speed Discharge Total Power Efficiency
S n Q Pressure Output
[%] [rpm] [l/s] [Pa] [W] [%]

60 2099 25,9 16 0,43 24,3


60 2099 24,0 18 0,42 23,8
60 2099 22,2 20 0,44 24,8
60 2039 11,2 25 0,28 15,4
60 2099 3,3 26 0,09 4,8
60 2039 0,0 28 0,00 0,0
70 2340 29,2 20 0,58 28,7
70 2278 24,7 25 0,62 30,4
70 2278 9,2 30 0,28 13,7
70 2278 6,0 31 0,19 9,1
70 2218 3,3 32 0,11 5,1
70 2278 1,5 34 0,05 2,3
80 2579 31,8 25 0,78 33,9
80 2519 26,5 29 0,78 33,8
80 2519 11,3 37 0,42 18,1
80 2519 8,2 37 0,30 12,9
80 2519 3,7 38 0,14 6,0
80 2459 1,5 40 0,06 2,4
90 2698 35,4 28 0,99 38,7
90 2698 30,5 34 1,03 39,7
90 2758 25,5 34 0,88 35,2
90 2698 9,1 43 0,39 14,9
90 2638 3,3 45 0,15 5,7
90 2638 1,5 47 0,07 2,5
100 2879 35,7 31 1,11 40,1
100 2818 30,1 38 1,15 41,5
100 2818 11,5 46 0,53 19,0
100 2818 7,5 48 0,36 13,0
100 2879 3,9 50 0,20 7,0
100 2758 1,5 52 0,08 2,6

Tabla.4. Datos calculados con apertura constante

Fan Fan Fan Fan Fan Overall


Setting Speed Discharge Total Power Efficiency
S n Q Pressure Output
[%] [rpm] [l/s] [Pa] [W] [%]

60 2099 25,8 17 0,44 24,8


70 2278 28,6 21 0,60 29,4
80 2519 31,2 25 0,76 33,1
90 2698 34,1 29 0,99 38,2
100 2818 35,7 31 1,11 40,0
60 2099 23,4 20 0,46 25,2
70 2340 26,1 24 0,63 30,5
80 2519 29,0 28 0,82 35,2
90 2758 31,3 33 1,04 39,7
100 2758 32,8 36 1,18 42,0
60 2099 18,8 20 0,38 21,9
70 2340 21,2 25 0,53 26,5
80 2579 22,9 30 0,69 30,9
90 2758 24,8 35 0,87 34,8
100 2879 26,5 38 1,02 37,9
60 2099 5,0 26 0,13 7,1
70 2278 5,4 32 0,17 8,3
80 2459 6,0 39 0,23 10,0
90 2698 6,2 44 0,27 10,4
100 2758 6,5 48 0,32 11,3
60 2039 1,5 28 0,04 2,2
70 2218 0,0 33 0,00 0,0
80 2399 1,5 41 0,06 2,4
90 2579 0,0 48 0,00 0,0
100 2758 1,5 52 0,08 2,6

9. Grficas
Fig.4. Presin vs Caudal con el ventilador a velocidad constante

Fig.5. Potencia til vs Caudal con el ventilador a velocidad constante


Fig.6. Rendimiento vs Caudal con el ventilador a velocidad constante

Fig.7. Presin vs Caudal con apertura constante


Fig.8. Potencia til vs Caudal con apertura constante

Fig.9. Rendimiento vs Caudal con apertura constante

10. Anlisis de Resultados

En las grficas obtenidas a velocidad constante la tendencia es la misma que la terica, la


presin disminuye conforme aumenta el caudal, la potencia til y el rendimiento aumenta
con el caudal.
En las graficas obtenidas con el ventilador a apertura constante el diferencial de presin
aumenta cuando la apertura disminuye mientras que la potencia til y el rendimiento
disminuyen, adems que con aperturas muy pequeas existen cambios drsticos en los
valores de presin, potencia til y rendimiento debido a la cada notoria de caudal.

11. Conclusiones
(Mosquera Lized)
En base a los datos experimentales obtenidos durante la prctica, se grafic varias
curvas en funcin del caudal, donde se observa un incremento proporcional de la
potencia til y el rendimiento, mientras que la presin disminuye.
Las grficas que se obtienen de las pruebas en el ventilador Axial del laboratorio
permitirn obtener datos de presin, potencia, y eficiencia, en determinadas
condiciones de trabajo
Considerando las grficas obtenidas, se compara las presiones, eficiencias,
potencia en sus diferentes ajustes (100, 80 y 60 [%]) y se evidencia que las curvas
disminuyen su pendiente a medida que se disminua el ajuste.

(Arias Francisco)
En los ventiladores axiales la presin disminuye conforme aumenta el caudal de
aire que ingresa al ventilador.
La potencia til y el rendimiento de un ventilador axial es directamente proporcional
al caudal de aire que ingresa.
Cuando existe caudales de aire muy bajos el rendimiento del ventilador es muy bajo
obtenindose valores que tienden a cero.

12. Recomendaciones
(Mosquera Lized)
Para las curvas que no muestren informacin suficiente, se puede trazar curvas de
tendencia y as realizar un ajuste en los datos del ventilador.
Al momento de tomar los datos, se debe esperar que se estabilice el caudal, para
evitar errores en los clculos.

(Arias Francisco)
Permitir que se estabilice la velocidad del ventilador para que al momento de la
toma de datos no existan errores
Mantener la entrada y salida de aire del equipo completamente libre para que no
exista variaciones en el caudal que sean ajenas a condiciones normales

Referencias:

Dixon, S. L. (2010). Fluid Mechanics and Termodynamics of Turbomachinery.


Oxford, UK: Elsevier.