FARADEL Earthing
Mobile & PREfab Earthing
Maintenance Free
Long Life
Solar Plant
Defence
Cement
Plants
Home &
Complex
Telecom
Stee! Plants
Railway
Transmission
& Distribution
Plot No-121, 88 Residency, Ushodaya Colony Phase-l!, Gajularamaram,
Qutbullapur, Hyderabad-500055, Contact: +91-9865815755, +91-9290143064,+91-9291230097
Ba ampress.hyd@gmail.com
Jyoti Colony, Vikrampuri, Hyderabad - 500009, Contact: +91-9652809323
Digdoh Hill, Indiramata Nagar, Nagpur - 440016, Contact: +91-9049701519| * Highly conductive earth pit bacfill
* Reduces soil resist by upto 90%
* Long if and non corrosive. Independent of ambient moisture content.
hares works in al wocthor conditions
* Compatible with ll typeof earthing electrodes. be it pips. plates or rads
of any materials
* Can also be usedin trenches made far horzortal type earthing system
* Increases tata surface area of earthing clectrade ensuring quick
Sa dissipation o faut currents
* Maintains coatant volume regardless of moisture content. Faradel
earthing compound does not shrink r expan. It maintan constant
contact with elecirade and surroundig sul
* Long shelfife: can be stored for very lng periads without
deterioration
* Ervironmental friendly does not pollite or contaminate the water
table
* Amprass offered Faradel compound is tasted by NABL carted
(VSR 1 Cpr bred te teste by ML
Certified laboratory PRI"
@ “28 we vevAN
wat @naco e
AEFDISOOIS —Ampress Faradel artting -SAt Lightning radial Earthing at building cellar
S Digging acessbilty upto Sft
AEFDIB0070 Ampress Faradel Earthing - Gft For all
AEFO300025 — Ampress Faradel Earthing - 10ftL
For all
iF yeu have need your own specication for earthing electrodes?” Give it tous, and we will
tailor-make it for your. Various terrains pose variaus challenge for making an earth pt We
understand that it sometimes becomes dificult to choose fram standard sizes. Give us the size
you need and we will have it ready for you.
In the event of faut the fault current wil try to dissipate into the ground through the earth connect
Allmetals are good conductors of electricity. hence the fault current easily passes through the earthing
conductor andthe earthing electrode. Te fault current faces major obstruction only atte interface
of the earthing electrode and surrounding si
Researchers from arround the world have proved that. if the soil immediately surrounding the clectrade
és replaced witha condoctive material the resistance of the interface canbe considerably reduced.
As seen from the relation, the earth resistance ofa given earth lecirade is drecty proportional to
soil resistivity‘. Lower the value of soi resistivity, lower wil be th earth resistance of electrode
Therefore by using Ampress prefah advanced earthing. the value of sil esistivity(p) can be considerably
reduced. This in tum wil reduce the earth resistance of the electrode. This also reduce the number of
electrodes required to achieve a pertcular earth resistance, thereby making the entire earthing system,
efficent, durable and cost effective. Where
p= Soil resistivity
R Zi at [1n—26_ 96L. ohms [= The electrode length
d= The electrode diameter