Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
Verification of Thermowell Form No: TS-I4003
Dtae: 13/02/09 Rev: 0
Signature
Name
Date
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT CALIBRATION REPORT FOR
Form No: TS-I4004
TEMPERATURE ELEMENT
Dtae: 13/02/09 Rev: 0
NAME/APPLN :
TAG NO. : AREA/LOCATION :
TYPE : MAKE :
MODEL NO : RANGE :
INST. SERIAL NO :
PRE-CALIBRATION INSPECTION :
TAG NUMBER CORRECT : YES / NO COMPLIANCE WITH SPECS. : YES / NO
REMARKS :
SIGN
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT CALIBRATION REPORT
(TRANSMITTERS) Form No: TS-I4005
PRE-CALIBRATION INSPECTION :
TAG NUMBER CORRECT SAFETY PROTECTION :
GENERAL CONDITION SATISFACTION INPUT CALIBRATION RANGE :
COMPLIANCE WITH SPECIFICATION OUTPUT CALIBRATION RANGE :
ZERO ELEVATION /SUPRESSION (IN ENGG. UNIT) :
AMBIENT CONDITION : FIELD / LAB. TEMP. : HUMIDITY :
TRANSMITTER DETAILS :
COMMUNICATION
TYPE OUTPUT FORM FAIL SAFE DIRECTION
MODE
SMART ANALOG LINEAR BURNOUT UPSCALE FAIL TO UPSCALE
ANALOG DIGITAL SQRT BURNOUT DOWNSCALE FAIL TO DOWNSCALE
HART SPECIAL BURNOUT LAST GOOD VALUE UNDEFINED
RESULT :
0%
25%
50%
75%
100%
75%
50%
25%
0%
REMARKS :
SIGN
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
SWITCH CALIBRATION REPORT ( PS/TS/LS-DPS ) Form No: TS-I4006
VALVE DETAILS :
COMMUNICATION
TYPE MODE OUTPUT FORM
SMART ANALOG LINEAR
ANALOG DIGITAL SQRT
HART SPECIAL
TEST EQUIPMENT :
TYPE OF EQPT MAKE MODEL # SERIAL # CERT NO CAL DATE EXP DATE
RESULTS :
INPUT % ACTUAL INPUT ACTUAL OUTPUT EXPECTED OUTPUT % ERROR REMARKS
0
25
50
75
100
75
50
25
0
REMARKS :
SIGN
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
LOCAL INSTRUMENT CALIBRATION REPORT (
PG/TG/LG ) Form No: TS-4007
Date: 13/02/09 Rev: 0
TAG NO : _______________________ INSTRUMENT DESCRIPTION: ___________________________
TYPE : _______________________ AREA/LOCATION : _________________________
MAKE / MODEL : _______________________ CALIBRATION RANGE : __________________________
P & ID NO : _______________________ SPECIFIED ACCURACY : __________________________
DATA SHEET NO & PAGE :____________________ SERVICE DESCRIPTION : _________________________
INSTRUMENT SERIAL NO :____________________ DATE OF CALIBRATION : __________________________
TYPE OF EQPT MAKE MODEL # SERIAL # CERT NO CAL DATE EXP DATE
TEST RESULTS :
deg c
deg C
0
25
50
75
100
75
50
25
0
REMARKS :
SIGN
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont: INSTRUMENT LOOP TEST SHEET - PRESSURE /
LEVEL / FLOW / TEMPERATURE TRANSMITTER / Form No: TS-I4008
OTHER TRANSMITTERS Dtae: 13/02/09 Rev: 0
INSTRUMENT KKS NO : ___________________________________
INSTRUMENT DESCRIPTION : ___________________________________
SERVICE : ___________________________________
REFERENCE P&I DIAGRAM : ___________________________________
REFERENCE LOOP DIAGRAM : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
MODEL : ___________________________________
RANGE : ___________________________________
INPUT SIGNAL : ___________________________________
DOUBLE/TRIPLE MEASUREMENT OK NA
DISCREPANCY OK NA
TREND OK NA
TOTALIZER OK NA
0% 75%
25% 50%
50% 25%
75% 0%
100%
OVER RANGE
UNDER RANGE
THRESHOLDS
SET ERROR SWITCHING VALUE
THRESHOL LOGIC
% During During DEAD BAND ALARM
DS Value FUNCTION
Meas. Percentage Increase Decrease
INVALID SIGNAL
MAX 2
MAX 1
MIN 1
MIN 2
REMARKS:
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT LOOP TEST SHEET - RTD Form No: TS-I4009
Dtae: 13/02/09 Rev:
INSTRUMENT DESCRIPTION : ___________________________________
SERVICE : ___________________________________
K.K.S.NUMBER : ___________________________________
REFERENCE P&I DIAGRAM : ___________________________________
REFERENCE LOOP DIAGRAM : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
MODEL : ___________________________________
RANGE ___________________________________
INPUT SIGNAL : RTD PT-100(
DOUBLE/TRIPLE MEASUREMENT OK NA
DISCREPANCY OK NA
TREND OK NA
TOTALIZER OK NA
0
RESISTANCE VALUE DCS INDICATION C
0
100 =0 C
THRESHOLDS
SET ERROR SWITCHING VALUE
LOGIC
THRESHOLDS % Meas. During During DEAD BAND ALARM
Value FUNCTION
Range Percentag Increase Decrease
INVALID SIGNAL
MAX 2
MAX 1
MIN 1
MIN 2
REMARKS:
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT LOOP TEST SHEET - DCS DIGITAL
Form No: TS-I4010
INPUT SIGNALS ( SWITCHES )
Dtae: 13/02/09 Rev: 0
INSTRUMENT DESCRIPTION : ___________________________________
SERVICE : ___________________________________
K.K.S.NUMBER : ___________________________________
REFERENCE P&I DIAGRAM : ___________________________________
REFERENCE LOOP DIAGRAM : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
MODEL : ___________________________________
RANGE : ___________________________________
ALARM SET POINT : ___________________________________
DISCREPANCY OK NA
THRESHOLDS
SET ERROR SWITCHING VALUE
DEAD LOGIC
THRESHOLDS % Meas. During During ALARM
Value BAND FUNCTION
Range Percentage Increase Decrease
INVALID SIGNAL
MAX 2
MAX 1
SEE RELEVANT CALIBRATION CERTIFICATE FROM I&C LABORATORY
MIN 1
MIN 2
SHORT CIRCUIT
WIRE BREAK
REMARKS:
SIGNATURE
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT LOOP TEST SHEET- MOTOR
Form No: TS-I4011
OPERATED VALVE
Dtae: 13/02/09 Rev: 0
SERVICE : ___________________________________
K.K.S.NUMBER : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
OPEN : _________________ Nm
CLOSED : _________________ Nm
OK N/A
CABLE CONTINUITY TEST / IR TEST
OPEN POSITION CLOSE POSITION
VALVE LIMIT SWITCH
LIMIT
CLOSING ON TORQUE
LIMIT
OPENING ON TORQUE
TRIP INTERLOCK
RELEASE INTERLOCK
REMARKS:
SIGNATURE
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
INSTRUMENT LOOP TEST SHEET - PNEUMATIC
Form No: TS-I4012
VALVES
Dtae: 13/02/09 Rev: 0
SERVICE : ___________________________________
K.K.S.NUMBER : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
REMARKS:
SIGNATURE
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
Instrument Loop Test - Solenoid Valve Form No: TS-I4013
Dtae: 13/02/09 Rev: 0
SERVICE : ___________________________________
K.K.S.NUMBER : ___________________________________
MANUFACTURER : ___________________________________
TYPE : ___________________________________
REMARKS:
SIGNATURE
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
SWITCH CALIBRATION REPORT ( PS/TS/LS-DPS ) Form No: TS-I4014
RESULTS :
NO CONTACT NC CONTACT DEAD BAND CABLE CORE
REMARKS :
SIGN
NAME
DATE
Client : SEC-EOA
Riyadh Power Plant # 10 " 10721026/00'
Contractor: BEMCO
Sub Cont:
TRUMENT & CONTROL CABLE MEGGER / CONTINUITY TEST REPOForm No: TS-I4001
CABLE SCREEN/
ITEM CONDUCTOR TO CONDUCTOR TO CONDUCTOR SHIELD TO CONTINUITY
CABLE NO. CABLE TYPE/SIZE FROM TO LENGTH - SHIELD TO REMARKS
NO. CONDUCTOR SHIELD TO ARMOUR SHIELD TEST
Mtrs ARMOUR
N/A
N/A
N/A
N/A
N/A
N/A
N/A
INSTRUMENT MAKE/MODEL :
Name
Signature
Date