DESIGN OF COLUMN FOOTING

Engr Sami Ullah | December 8, 2017 | Concrete Technology | 2 Comments


Written by: Engr Sami Ullah Stanikzai (www.civilglobal.com)
In this article I will Design the square column footing in detail. but this is the part -1 and part -2 will be
coming soon. after reading this article you will be able to design the square column in detail. and this
is the important article for all civil engineers students.
In this procedure I am just assuming the data for column footing so, you are also able to change this
value and use in these formula which I am showing you here in this article.

REQUIRED STEPS TO DESIGN A COLUMN:


1: Area of column footing

2: Soil Reaction
3: Factor moment

4: Required depth of footing (d)

GIVEN DATA:
Applied load on the column = p = 2000 kN
Size of column = 400mm x 400mm

Soil bearing capacity = S.B.C = 150 KN/m2


we will use here M20 grade of concrete in this column

Grade of Steel = fe = 415


compressive strength of concrete = fy = 20 N/mm2
Solution of first step: Area of footing
Area of footing = 10% of P+P / S.B.C
Here we increase the applied load 10% of P

Here (P) is applied load and S.B.C ( Soil bearing capacity)


SOLUTION:
Area of footing = 10% of P+P / S.B.C = 0.1 x 2200 + 2200 / 150 = 14.55 m2

now footing one side = A = 14.55 = 3.28 m say 4 meter.

Solution of second step: Soil Reaction

use the given formula for soil reaction


qu = Pu / A where pu is the factor load of the column and A is the area of footing
the value of pu = 1.5 x P so = 1.5 x 2200 = 3300 KN
so now . qu = Pu / A = 3300 / 14.55 = 225.10 KN/m2
Solution of 3rd Step : Factor movment

use the given formula for factor moment


Mu = P x B x (S b/ 2 )2 1/2 where P =Load , B = breadth of footing , S = Side of footing , b =
side of column.
so, P x B x (S b/ 2 )2 1/2 = 2200 x 4 x (4 0.40/ 2 )2 1/2 = 1780 KN.

Solution of 4th Step : required depth of footing (d)


use the given formula for depth of footing (d)

d = Mu / 0.138 x fck x B where Mu = factor moment , fck = compresive strength of concrete ,


B = Breadth of footing.
so,

d = Mu / 0.138 x fck x B But here we will change Mu value to N.mm so Mu multiply x 106
d = 17820 x 106 / 0.138 x 20 x 4000 so , d = 401 mm say 0.4m
Note: In this next Article part -2 we will discuss about the steel design in this column but it will be the
full design of column footing. so read this article carefully and do your own design of any column and
assume the data for the column footing , and make it easy for your self. wait for next part -2 article.

Written by: Engr Sami Ullah Stanikzai (www.civilglobal.com)


if you want to watch this video than just click on my You Tube channel Link : Civil Engineers

Post Views: 1,383


Tags:Column footing design, Design of column footing, Design of square column footing

RELATED POSTS

COMPRESSIVE STRENGTH OF CONCRETE

No Comments | Nov 24, 2017

HOW TO SELECT SUITABLE GRADE OF CONCRETE FOR CONSTRUCTION

1 Comment | Nov 29, 2017

WORKABILITY OF CONCRETE.

1 Comment | Jul 10, 2017

CHECKLIST FOR RCC SLABS & BEAM BEFORE STARTING CONCRETE

4 Comments | Nov 24, 2017

ABOUT THE AUTHOR

Potrebbero piacerti anche